Transcript
Page 1: MovinCool Classic 40/60 Series - Trane · MovinCool Classic 40/Classic 60 Series Multiple or Remote Area Cooling Cooling several hot spots is not a problem with the two or three-way

MovinCool®

Classic 40/60 Series

The Portable Spot Cooling Solution

Page 2: MovinCool Classic 40/60 Series - Trane · MovinCool Classic 40/Classic 60 Series Multiple or Remote Area Cooling Cooling several hot spots is not a problem with the two or three-way

Time tested and proven in the world’s workspaces for over 20 years

The MovinCool Classic 40/Classic 60Series has been cooling the world’sfactories, warehouses and workspacesfor over twenty years. Unparalleledreliability and rugged design hasmade the Classic 40/Classic 60 thechoice for production managers,quality engineers and, warehouseoperators.

Improves manufacturingquality, protects employeesand equipment.Portable air conditioners provide easy-to-use, affordable and, flexible spotcooling solutions instantly, providingup to 60,000 Btu/h of air conditioningto just the spot that needs it!

Simply roll it in,plug it in and turn it on!

Benefits

• Maximum spot-cooling Btu/hprovides cool air to larger work areas

• Add multiple drop ducts to cool eachworker or seperate work areas

• A wide array of ducting options forcustom-cooling configurations

• Performs in the harshestenvironments

• Operates in temperatures rangingfrom 75° to 115°F

• All-in-one design makes operationvirtually maintenance free

Features

• Up to 60,000 Btu/h of cooling

• Multiple cooling ducts

• Versatile

• Rugged design

• Handles extreme temperatures

• Totally self-contained

The Classic 40/60RSP-SLB065-EN© 2002 American Standard Inc. All rights reserved

Page 3: MovinCool Classic 40/60 Series - Trane · MovinCool Classic 40/Classic 60 Series Multiple or Remote Area Cooling Cooling several hot spots is not a problem with the two or three-way

MovinCool Classic 40/Classic 60 Series

Multiple or Remote Area CoolingCooling several hot spots is not a problem with the two or three-way chamber. Extension ducts in 10 ft sections can be used to bring coolingto remote or different locations. Attach trim rings at the end of the extension ducts to give a finished look and keep the ducts fromunraveling.

# PART NAME Classic 40 Classic 60

Trane PN MovinCool PN Trane PN MovinCool PN

1 Cold Air Flange FLG01056 481170-0190 FLG01056 481170-0190

2 Chamber Extender CHB00160 481849-1431 CHB00160 481849-1431

Chamber Extender Flange FLG01053 481170-0090 FLG01053 481170-0090

3 Two-way Chamber CHB00158 481769-0041 CHB00158 481769-0041

Three-way Chamber (not shown) CHB00159 481769-0051 CHB00159 481769-0051

Reducer Flange N/A N/A FLG01054 481170-0150

4 Extension Duct (6 in.) DUC01041 481744-0030 DUC01041 481744-0030

5 Trim Ring RNG01761 481851-0210 RNG01761 481851-0210

6 Extension Duct (12 in.) DUC01043 481744-0060 DUC01043 481744-0060

PortabilityTo allow portability of these high-capacity MovinCool units, use the roller kit or the wagon kit. The stand kit provides proper ground clearancefor permanent exterior installations.

# PART NAME Classic 40 Classic 60

Trane PN MovinCool PN Trane PN MovinCool PN

7 Stand Kit KIT07918 484750-0020 N/A N/A

8 Wagon Kit KIT07917 484710-0020 N/A N/A

9 Caster Kit KIT07916 484709-0011 WHL02263 484709-0020

Remote ControlWhen the unit is installed in a remote location, such as outdoors or overhead, use the remote control to allow convenient access to controls.The kit includes the operational control, a cover plate to prevent tampering with controls, and installation hardware. Use six 18AWG plus oneground wire to connect the control to the unit (wire not included).

# PART NAME Classic 40 Classic 60

Trane PN MovinCool PN Trane PN MovinCool PN

10 Remote Control Kit CNT03695 484500-0430 CNT03695 484500-0430

RSP-SLB065-EN

Remote Control Kit Multiple Area Cooling Remote Cooling Stand/Wagon/Caster Kit

Page 4: MovinCool Classic 40/60 Series - Trane · MovinCool Classic 40/Classic 60 Series Multiple or Remote Area Cooling Cooling several hot spots is not a problem with the two or three-way

9

8

7

2

1

34 4

5

106

Parts Descriptions Classic 40/Classic 60 1 Cold Air Flange 12 in. diameter gray metal flange with wire clamp and mounting screws.

2 Chamber Extender Gray metal cylinder raises exhaust air chamber 16 in. above unit.

Chamber Extender Flange (not shown) Gray metal flange connects chamber extender to unit.

3 Two-way Chamber Insulated gray plastic chamber diverts airflow in two directions. Use 6 in. extension ducts.

Three-way Chamber (not shown) Diverts airflow in three directions. Use 6 in. extension ducts.

Reducer Flange (not shown) Gray metal flange converts mounting holes on Classic 60 for two- or three-way chamber

and chamber extender flange.

4 Extension Duct 6 in. adjustable diameter white plastic duct that extends from 61⁄2 ft to 10 ft in length.

5 Trim Ring 6 in. diameter black plastic end cap for extension duct.

6 Extension Duct 12 in. adjustable diameter white plastic duct that extends from 61⁄2 ft to 10 ft in length.

7 Stand Kit Blue metal, tubular frame raises unit off the ground. Available for Classic 40 only.

8 Wagon Kit Blue metal, tubular frame with four casters, drain spout assembly and two 5 gal

condensate tanks. Available for Classic 40 only.

9 Caster Kit Four casters and wrench.

10 Remote Control Kit Kit includes remote control box and installation hardware. Use six 18AWG plus one ground

wire (wire not included).

Accessories

RSP-SLB065-EN

Page 5: MovinCool Classic 40/60 Series - Trane · MovinCool Classic 40/Classic 60 Series Multiple or Remote Area Cooling Cooling several hot spots is not a problem with the two or three-way

Classic 40/Classic 60 Specs

DENSO SALES CALIFORNIA, INC.REGISTERED TO ISO 9002

FILE NO. A5537

All specifications subject to change without notice. Standard warranty includes 12 months on entire unit. All models are UL listed and feature compressor overload relayand fan motor protection. All models are 50 hertz (Hz) compatible with a slight decrease from specifications listed above. * This model does not come with a power cord.To hard wire the unit, use the specified wire gauge.

©2002 DENSO SALES CALIFORNIA, INC.MovinCool is a registered trademark

of DENSO Corporation.

Electronic Features Control PanelThermostat Control

Cooling Capacity Rating conditions: 95°F at 60% RH

Electrical Voltage RequirementCharacteristics Total Power Consumption

Current ConsumptionRecommended Fuse SizeNEMA Plug ConfigurationMin.–Max. Voltage

Fans Motor Output–high/low

Evaporator Fan TypeMax. Air Flow–high/lowMax. External Static Pressure

Condenser Fan TypeMax. Air Flow–high/lowMax. External Static Pressure

Compressor TypeOutput

R-22 Charge

Dimensions W x D x HNet Weight / Shipping Weight

Power Cord GaugeLength

Condensate Tank Capacity

Operating Conditions Min.–Max. (@ 50% RH)Max. Duct Length Per Cold Duct Hose

Hot Duct HoseMax. Sound Level With Condenser Duct–high/low

Without Condenser Duct–high/low

MechanicalMechanical60,000 Btu/h

3 Phase, 460V7.2 kW10.5 amps20 ampsN/A440–4800.75 kW Evap.0.40 kW Cond.Centrifugal1580 CFM1.35 IWGPropeller3800 CFM0.05 IWGHermetic Reciprocal3.75 kW5.9 lbs32 x 49 x 42 in.463 lbs./545 lbs12AWG (4-core)*N/AN/A75°–115° FVaries (Max 65 ft)40 ft N/A72 dB

MechanicalMechanical39,000 Btu/h

3 Phase, 220V4.7 kW14.0 amps25 ampsL15–30187–2530.75 kW Evap.0.40 kW Cond.Centrifugal1060 CFM1.72 IWGPropeller2650 CFM0.05 IWGHermetic Reciprocal 2.2 Kw4.4 lbs26 x 43 x 39 in. 353 lbs./420 lbs12AWG (4-core)6 ft2 @ 5 gal (optional)75°–115° FVaries (Max 65 ft)40 ft N/A72 dB

RSP-SLB065-EN

MovinCool PN Classic 40 Classic 60Trane PN UNT00865 UNT00866

Page 6: MovinCool Classic 40/60 Series - Trane · MovinCool Classic 40/Classic 60 Series Multiple or Remote Area Cooling Cooling several hot spots is not a problem with the two or three-way

Literature Order Number

Date

Supersedes

Stocking Location

Trane has a policy of continuous product and product data improvement and reserves the right to changedesign and specifications without notice.

The Trane Company

An American Standard Company

www.trane.com

For more information contactyour local district office ore-mail us at [email protected]

RSP-SLB065-EN

February 2002

New

La Crosse


Recommended