Transcript
Page 1: ID Fan Capability - Amazon S3€¦ · testing to relevant codes such as ASME PTC 11 - Fans • auditing fan design using stress and modal analysis (finite element methods), impulse

HRL Technology Group Pty Ltd ABN 89 609 887 327 [email protected] hrl.com.au

Melbourne Level One Unit 4 677 Springvale Road Mulgrave VIC 3170 Phone +61 3 9565 9888 Fax +61 3 9565 9879

Morwell Tramway Road Morwell VIC 3840

Phone +61 3 5132 1500 Fax +61 3 5132 1580

Queensland Unit 2 33-37 Rosedale Street Coopers Plains QLD 4108 Phone +61 7 3423 4300 Fax +61 7 3345 5937

1

IDFan

Cap

ability

hrl:

IDFanCapabilityOptimisinginduceddraftfanperformanceandreliability

ChallengesSub-optimalinduceddraft(ID)fanperformancecanleadtoshort-andlong-termissuessuchas:• prematurecrackingoffanimpellers• increasedpowerconsumptionandhenceauxiliaryload• damagetofanimpellersthrougherosion.

Solutionshrl:canhelpplantoperatorsmeetthesechallengesby:• providingindependentIDfanperformance/acceptance

testingtorelevantcodessuchasASMEPTC11-Fans• auditingfandesignusingstressandmodalanalysis

(finiteelementmethods),impulsetesting,fatigueassessmentsandstraingaugesurveys

• undertakingprocessmodellingandcomputationalfluiddynamics(CFD)modellingofthefansandsurroundingductworkunderexistingandpotentialoperatingconditions.

Benefitshrl:servicesandexpertiseprovideplantoperatorswithnumerousbenefits,including:• independentacceptancetestingtoensureoriginal

equipmentsuppliersperformanceguaranteesaremet• performancetestingandprocessmodellingproviding

insightintohowplantoperatingconditionsareimpactingonIDfanperformanceandefficiency

• auditingfandesignstodeterminethesteadystate,staticanddynamicstressesexperiencedduringoperation;andthemodefrequenciesandshapes,tohelpdeterminethecauseandriskofprematurecracking

• auditingthatcanalsodetermineexpectedfanlifeandassistindevelopingweld-repairprocedures

• usingcomputationalfluiddynamicsmodellingtorevealtheunderlyingflowstructureswithinthefanandsurroundingductworktodiagnoseperformanceissuessuchasvibrationcausedbythefanoritsinteractionwithsurroundingductwork

• usingCFDmodellingtopredicterosionpatternscausedbyparticle-ladenflowstohelpplanmaintenanceandcomparescenariostominimisesucherosion.

Page 2: ID Fan Capability - Amazon S3€¦ · testing to relevant codes such as ASME PTC 11 - Fans • auditing fan design using stress and modal analysis (finite element methods), impulse

2

Case Study Investigating premature cracking in an ID fan AnAustralianpowerstationfoundsignificantcrackingwithintheimpellerononeoftheirinduceddraftfans.Theimpellerhadbeenreplacedthreeyearsearlierandhadbeensubjectedtoseveraldesignchanges,suchthatthereplacementimpellercouldbeconsideredasadifferentstructuretotheoriginal.hrl:wasengagedbythepowerstationoperatorstoinvestigatetherootcauseofprematurecrackinginthenewimpeller.hrl:investigatedthecrackingby:• installing(wireless)straingaugesontothenewimpeller

tosurveystrainduringstart-upandnormaloperation• undertakingafiniteelementanalysis(FEA)ofthefanto

determinetheresonantfrequencyoftheimpellerandmodeshapeofthenaturalfrequencies

• undertakingsteady-stateanalysistocomparetheoperatingmeanstressofthenewimpellertotheoriginal

• performingastiffenedmodalanalysistodeterminethesystem’snaturalfrequenciesandmodalshapes

• performinganunstiffenedmodalanalysistodeterminestaticnaturalfrequenciesforvalidationagainstimpacttestingresults

• performancetestingofthefanduringoperationtodetermineitsefficiencyunderdifferentoperatingconditions.

hrl:establishedthemostprobablecauseofthecrackingtobevibration,possiblylinkedtothechangedimpellerdesign.hrl:providedthepowerstationoperatorswithoptionstopreventfurthercrackingoftheirIDfans.hrl:recommended:• thefanmanufacturerreviewthefanflow-design

characteristicsbasedontheperformancetestdatahrl:collectedunderplantoperatingconditions–nearstallatlowload

• tomitigatetheflow-inducedvibration,thestationtoconsiderasmallerfan,orinstallingavariablespeedfanorbypassductsystem

• installingflue-gasflowmeasurementdevicesonbothfanstoeliminatebiastoonefan

• specificoperatinginstructionstoavoidrunningthefanatnear-stallcondition.

Contact JamesTaylor

[email protected]

Contact DaoNguyen

[email protected]

Needmoreinformation?Gotohrl.com.au

Thecompany’sNATAAccreditedLaboratoriesnumberis561.

HRLTechnologyGroup’sISO9001QualityManagementiscertifiedbyBSIundercertificateFS605116