Page 1: High Temperature, High Pressure Electrolysis...High Temperature, High Pressure Electrolysis Giner, Inc Cortney Mittelsteadt Jason Willey Robert Stone Virginia Tech Judy Riffle Jarrett

This presentation does not contain any proprietary, confidential,or otherwise restricted information

High Temperature, High Pressure Electrolysis

Giner, IncCortney Mittelsteadt

Jason WilleyRobert Stone

Virginia TechJudy Riffle

Jarrett RowlettAmin Daryaei

Jim McGrath

Project PD1171

Page 2: High Temperature, High Pressure Electrolysis...High Temperature, High Pressure Electrolysis Giner, Inc Cortney Mittelsteadt Jason Willey Robert Stone Virginia Tech Judy Riffle Jarrett

This presentation does not contain any proprietary, confidential,or otherwise restricted information

Barriers Addressed• Hydrogen Cost $4-5/kgTechnical Targets Phase I• 2x Conductivity: Permeability

Ratio at end of Ph I• Phase II• 3x Ratio• 95°C Operation for 1000 h

5000 psi operation for 1000 h• Stack Delivery to DOE

(NREL?) at end of PhII

Timeline• Project Start Date:

2/18/2014 (PI)• Project End Date:

12/17/2016Budget• Fast-track $1.0M

– Giner $780k• $421 k Spent

– Virginia Tech $370k• $134k Spent• Contract delayed with

passing of J.McGrathPartners• Virginia Tech

Project Overview

2

Page 3: High Temperature, High Pressure Electrolysis...High Temperature, High Pressure Electrolysis Giner, Inc Cortney Mittelsteadt Jason Willey Robert Stone Virginia Tech Judy Riffle Jarrett

This presentation does not contain any proprietary, confidential,or otherwise restricted information

Relevance: Pressure

Not Possible to have high efficiency at high pressure with current membranesIncreasing ratio is key to having large operating range: Essential for Renewables!

3

Page 4: High Temperature, High Pressure Electrolysis...High Temperature, High Pressure Electrolysis Giner, Inc Cortney Mittelsteadt Jason Willey Robert Stone Virginia Tech Judy Riffle Jarrett

This presentation does not contain any proprietary, confidential,or otherwise restricted information

Relevance: Pressure

60°C 3500 PSI electrolyzer Nafion 110

Pressure always on to increase it!

Reduce CompressionAnd maintenance costs

MEA(After Disassembly)

4

Page 5: High Temperature, High Pressure Electrolysis...High Temperature, High Pressure Electrolysis Giner, Inc Cortney Mittelsteadt Jason Willey Robert Stone Virginia Tech Judy Riffle Jarrett

This presentation does not contain any proprietary, confidential,or otherwise restricted information

Relevance: Temperature

Nearly 1 mV/°C decrease in Reversible VoltageLarger TΔS means less heat to remove

David Anthony, James Rand and Ronald Dell Hydrogen Energy Challenges and Prospects 2008.

5

Page 6: High Temperature, High Pressure Electrolysis...High Temperature, High Pressure Electrolysis Giner, Inc Cortney Mittelsteadt Jason Willey Robert Stone Virginia Tech Judy Riffle Jarrett

This presentation does not contain any proprietary, confidential,or otherwise restricted information

Relevance: Temperature

Oxygen Evolution ReactionHas a High Activation Energy~ 30 kJ/mol

Going from 60 to 100°C results in an almost order of magnitude increase in kinetics

0123456789

10

0 20 40 60 80 100 120 140Rel

ativ

e E

xcha

nge

Cur

rent

Den

sity

60

°C =

1

Temperature °C

6

Page 7: High Temperature, High Pressure Electrolysis...High Temperature, High Pressure Electrolysis Giner, Inc Cortney Mittelsteadt Jason Willey Robert Stone Virginia Tech Judy Riffle Jarrett

This presentation does not contain any proprietary, confidential,or otherwise restricted information

Relevance: $

$100

$1,000

$10,000

$100,000

-0.04

-0.02

0

0.02

0.04

0.06

0.08

0.1

40 60 80 100 120

Cat

alys

t Cos

t for

1 G

W E

lect

roly

zer

Volta

ge I

mpr

ovem

ent O

ver 6

0°C

O

pera

tion

Temperature °C

Kinetic Voltage Gain Thermodynamic Voltage Gain$Ir/Kg/hr Stack

7

Page 8: High Temperature, High Pressure Electrolysis...High Temperature, High Pressure Electrolysis Giner, Inc Cortney Mittelsteadt Jason Willey Robert Stone Virginia Tech Judy Riffle Jarrett

This presentation does not contain any proprietary, confidential,or otherwise restricted information

Approach: Work Plan

Phase II is behind schedule in terms of timing, but not funding.PFSA membrane selection has taken placeCatalyst formulation is completeHydrocarbon formulation is still undergoing 5000 psi testing has just begun

8

Page 9: High Temperature, High Pressure Electrolysis...High Temperature, High Pressure Electrolysis Giner, Inc Cortney Mittelsteadt Jason Willey Robert Stone Virginia Tech Judy Riffle Jarrett

This presentation does not contain any proprietary, confidential,or otherwise restricted information

Accomplishments: Task 1. Build Test Station: 100% Complete

5000 PSI System Capable of Stack Testing is Available

Fabricated on DOE Home Refueling Program

Modified for diagnostic testing, individual cell monitoring

9

Page 10: High Temperature, High Pressure Electrolysis...High Temperature, High Pressure Electrolysis Giner, Inc Cortney Mittelsteadt Jason Willey Robert Stone Virginia Tech Judy Riffle Jarrett

This presentation does not contain any proprietary, confidential,or otherwise restricted information

• Four Types of Membranes:1. Different EW 2. Additives to limit crossover3. Additives to limit degradation4. Hydrocarbons

COMPLETED

– Nafion 1100 EW• Used as the standard

– Nafion 1100 EW treated with cross-over additive– Solvay Aquivion 790 EW

• Short-chain PFSA– 3M 825 EW

• Short-chain PFSA

Accomplishments: Task 2. Generate PFSA Membranes100% Complete

10

Page 11: High Temperature, High Pressure Electrolysis...High Temperature, High Pressure Electrolysis Giner, Inc Cortney Mittelsteadt Jason Willey Robert Stone Virginia Tech Judy Riffle Jarrett

This presentation does not contain any proprietary, confidential,or otherwise restricted information

– Biphenol Sulfone (BPSH) 20% and 33%

– Hydroquinone Sulfone (HQS) 22%

– Hexafluorobipehnol Sulfone - Hydroquinone Sulfone (6FBPS0-HQSH)

– Hexafluorobipehnol Sulfone - Biphenol Sulfone (6FBPSO-BPSH)

– Hexafluoroketone Bipehnol Sulfone (6FKBPSH)

Accomplishments: Task 3. Generate HC Membranes100% Complete

11

Page 12: High Temperature, High Pressure Electrolysis...High Temperature, High Pressure Electrolysis Giner, Inc Cortney Mittelsteadt Jason Willey Robert Stone Virginia Tech Judy Riffle Jarrett

This presentation does not contain any proprietary, confidential,or otherwise restricted information

01234567

Rat

io n

orm

aliz

ed to

N11

00

Normalized C/P ratio at 95°C

Accomplishments: Task 4. Measure Conductivity to Permeability Ratio

Exceeded go/no-go with 3 membranes, almost 4.

Go/No-Go ratio = 2

12

Page 13: High Temperature, High Pressure Electrolysis...High Temperature, High Pressure Electrolysis Giner, Inc Cortney Mittelsteadt Jason Willey Robert Stone Virginia Tech Judy Riffle Jarrett

This presentation does not contain any proprietary, confidential,or otherwise restricted information

Accomplishments: Task 6. Temp 40-95°C, 7-70 bar

Test #

Membrane Type XM* DM (%)**

Test length (hrs)

Failure Est. Life (hrs)†

1 N115 PFSA yes 0 518 no 7,0002 N115 PFSA yes 0.25 456 no >100,0003 N115 PFSA yes 0.5 411 no >100,0004 N115 PFSA yes 1 552 no >100,0005 N115 PFSA yes 2.5 1017 no >100,0006 Solvay E79 PFSA yes 0 697 no 4,0007 Solvay E79 PFSA/DSM yes 0.5 488 no 15,0008 Solvay E79 PFSA yes 0.5 356 yes -9 HQS-22 HC/DSM no 0 25 no -10 HQS-22 HC/DSM yes 0 41 yes -12 HQS-22 HC yes 0 74 yes -13 HQS-22 HC/DSM yes 0.5 20 yes -14 HQS-22 HC/DSM yes 0.5 2 yes -

* XM = Crossover Mitigation Added. ** DM = Degradation Mitigation Level as multiple of baseline amount.† Estimated Lifetimes are for MEAs operated at 95°C and 70 bar. Lifetimes are estimated by loss of 10% of membrane fluoride inventory as measured by F- release in cathodic water.

13

Page 14: High Temperature, High Pressure Electrolysis...High Temperature, High Pressure Electrolysis Giner, Inc Cortney Mittelsteadt Jason Willey Robert Stone Virginia Tech Judy Riffle Jarrett

This presentation does not contain any proprietary, confidential,or otherwise restricted information

Accomplishments: Task 6. Degradation Mitigation

1.450

1.550

1.650

1.750

1.850

1.950

2.050

2.150

2.250

2.350

0 500 1000 1500 2000 2500 3000 3500 4000

Volta

ge (V

)

Current Density (mA / cm2)

DOE - Polarization ScansNafion - 115 @ 80 °C @ 70 bar

Various Degradation Mitigation Levels

No mitigant0.25x Baseline0.5x BaselineBaseline2.5x Baseline

Higher mitigant levels affect performance, especially at higher current density

14

Page 15: High Temperature, High Pressure Electrolysis...High Temperature, High Pressure Electrolysis Giner, Inc Cortney Mittelsteadt Jason Willey Robert Stone Virginia Tech Judy Riffle Jarrett

This presentation does not contain any proprietary, confidential,or otherwise restricted information

Accomplishments: Task 6. Alternate PFSA

Performance of Solvay E79 MEA (100 µm thickness) is higher than N115 at the stated conditions

1.40

1.50

1.60

1.70

1.80

1.90

2.00

2.10

2.20

0 1000 2000 3000 4000 5000

Volta

ge (

V )

Current Density ( mA/cm2 )

DOE - Nafion N115 - Solvay E79 Comparison 0.5x Baseline, 95°C, 70 bar

Solvay E79 MEA 330 hoursNafion N115 MEA 335 hours

Notebook #840, pgs. 70-75

15

Page 16: High Temperature, High Pressure Electrolysis...High Temperature, High Pressure Electrolysis Giner, Inc Cortney Mittelsteadt Jason Willey Robert Stone Virginia Tech Judy Riffle Jarrett

This presentation does not contain any proprietary, confidential,or otherwise restricted information

Accomplishments: Task 7. Optimize Catalyst Layer

• At high temperature the ionomer in the catalyst layer swells, reducing electrical contact of the catalyst particles and decreasing the performance gain

• Giner has started work on a catalyst layer with higher equivalent weight ionomer to reduce swelling at high temperatures

16

Page 17: High Temperature, High Pressure Electrolysis...High Temperature, High Pressure Electrolysis Giner, Inc Cortney Mittelsteadt Jason Willey Robert Stone Virginia Tech Judy Riffle Jarrett

This presentation does not contain any proprietary, confidential,or otherwise restricted information

Relative stability against loss of –SO3H by electrophilic aromatic substitution in strong acid: H+

Accomplishments: Task 8. Develop Improved Hydrocarbon Membrane

Future Work is to increase chemical stability of the chain itself

Page 18: High Temperature, High Pressure Electrolysis...High Temperature, High Pressure Electrolysis Giner, Inc Cortney Mittelsteadt Jason Willey Robert Stone Virginia Tech Judy Riffle Jarrett

This presentation does not contain any proprietary, confidential,or otherwise restricted information

Accomplishments: Task 9&10. 350 bar Testing

• A Solvay E79 DSM MEA has been fabricated for installation in the high pressure hardware to begin 350 bar operation.

18

Page 19: High Temperature, High Pressure Electrolysis...High Temperature, High Pressure Electrolysis Giner, Inc Cortney Mittelsteadt Jason Willey Robert Stone Virginia Tech Judy Riffle Jarrett

This presentation does not contain any proprietary, confidential,or otherwise restricted information

Collaborations

• Virginia Tech– Subcontractor, generating alternative membranes– Employed Student at Giner for one Week to

maximize interaction

• 3M– Supplying Ionomer

19

Page 20: High Temperature, High Pressure Electrolysis...High Temperature, High Pressure Electrolysis Giner, Inc Cortney Mittelsteadt Jason Willey Robert Stone Virginia Tech Judy Riffle Jarrett

This presentation does not contain any proprietary, confidential,or otherwise restricted information

Future Work:

• Task 6. Two more test– Repeat of Solvay DSM– New hydrocarbon MEA

• Task 7. Optimal Catalyst Formulation– Effective lower loading– Higher EW ionomer– Post-mortem testing

• Task 9-10. 5000 psi, 95°C testing• Task 11. Short Stack Testing• Task 12. Long-term verification (5000h goal)

20

Page 21: High Temperature, High Pressure Electrolysis...High Temperature, High Pressure Electrolysis Giner, Inc Cortney Mittelsteadt Jason Willey Robert Stone Virginia Tech Judy Riffle Jarrett

This presentation does not contain any proprietary, confidential,or otherwise restricted information

Summary

• Four membranes developed with a 2x Conductivity/Permeability Ratio improvement

• 1000 h at 95°C demonstrated• 500 h at 95°C and 1000 psi demonstrated• MEA testing of hydrocarbon materials• 14 tests at 70 bar completed to determine high-

pressure candidate• High pressure (5000 psi) test to begin soon

21

Page 22: High Temperature, High Pressure Electrolysis...High Temperature, High Pressure Electrolysis Giner, Inc Cortney Mittelsteadt Jason Willey Robert Stone Virginia Tech Judy Riffle Jarrett

This presentation does not contain any proprietary, confidential,or otherwise restricted information

Response to Reviewers Comments• Overall reviews were quite positive, we report only on the constructive criticisms or where we believe there

may be a misunderstanding. Comments are in black, our responses in red.

• While the C/P ratio is good for screening, it is also desired to simultaneously have high conductivity. Thus, screening for conductivity might be an important adjunct to the C/P metric.

– We are confused by the reviewers comment. In order to obtain the conductivity/permeability ratio we must measure each. In the absence of mechanical failure, we can choose our membrane thickness based on acceptable permeability, each are equally important.

• Additional testing of the alternative membranes is both necessary and planned. Actual validation at 5000 psi (with comparison to the baseline membrane) is critical.

– We will test at 5000 psi, we do disagree however as how critical this is to overall success of the program as we believe there are only few cases where direct electrolysis to 5000 psi are economical.

• It is not clear whether the proposed process to directly generate high-pressure hydrogen is more economically valuable than the existing techniques, which generate hydrogen at low pressures and then use compression

– We agree with the reviewers comments that direct high pressure electrolysis is not always the most economical. In cases where footprint and maintenance are key drivers however it can be the difference between H2 being accepted. We will do a more thorough case analysis this period

22


Recommended