Page 1: Downflow/Horizontal Right or Downflow/Horizontal …...2012/06/22  · Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace PUB. NO. 22-1671-10 XR 80 TDD1A040A9241A,

Downflow/Horizontal Right orDownflow/Horizontal LeftInduced Draft Gas Furnace

PUB. NO. 22-1671-10

XR 80TDD1A040A9241A, TDD1A060A9241A, TDD1A060A9361A,TDD1B060A9361A, TDD1B080A9361A, TDD1B080A9451ATDD1B100A9451A, TDD1C100A9481A, TDD1C100A9541ATDD1C120A9541A, TDD1D120A9601A, TDD1D140A9601A

Single-Stage Fan AssistedCombustion System

Page 2: Downflow/Horizontal Right or Downflow/Horizontal …...2012/06/22  · Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace PUB. NO. 22-1671-10 XR 80 TDD1A040A9241A,

© 2009 Trane All Rights Reserved 2 22-1671-10

GeneralFeatures

Natural Gas ModelsCentral Heating furnace designs arecertified by the American and CanadianGas Associations for both natural andL.P. gas. Limit setting and rating datawere established and approved understandard rating conditions usingAmerican National Standards Institutestandards.

Safe OperationThe Integrated System Control has solidstate devices, which continuously monitorfor presence of flame, when the system isin the heating mode of operation. Dualsolenoid combination gas valve andregulator provide extra safety.

Quick HeatingDurable, cycle tested, heavy gaugealuminized steel heat exchangerquickly transfers heat to provide warmconditioned air to the structure.

BurnersMulti-port In-shot burners will give yearsof quiet and efficient service. All modelscan be converted to L.P. gas.

Integrated System ControlExclusively designed operational pro-gram provides total control of furnacelimit sensors, blowers, gas valve, flamecontrol and includes self-diagnostics forease of service. Also contains connec-tion points for E.A.C./humidifier.

Air DeliveryThe 4-speed, direct drive blower motor,has sufficient airflow for most heating andcooling requirements, will switch fromheating to cooling speeds on demandfrom room thermostat. The blower doorsafety switch will prevent or terminatefurnace operation when the blower dooris removed.

StylingHeavy gauge steel and “wrap-around”cabinet construction is used in thecabinet with baked-on enamel finish forstrength and beauty. The heatexchanger section of the cabinet iscompletely lined with foil faced fiberglassinsulation. This results in quiet andefficient operation due to the excellentacoustical and insulating qualities offiberglass.

Features andGeneral OperationThe XR 80 High Efficiency Gas Furnaceemploys an adaptive Hot Surface Ignitionsystem, which eliminates the waste of aconstant burning pilot. The integratedsystem control lights the main burnersupon a demand for heat from the roomthermostat. Complete front serviceaccess.

a. Low energy power venterb. Vent proving pressure switch.

Page 3: Downflow/Horizontal Right or Downflow/Horizontal …...2012/06/22  · Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace PUB. NO. 22-1671-10 XR 80 TDD1A040A9241A,

22-1671-10 3

Contents

General Features 2

Features and Benefits 4Standard Equipment 4Optional Equipment 5

General Data 6TDD1A040A9241A 6TDD1A060A9241A 6TDD1A060A9361A 6TDD1B060A9361A 7TDD1B080A9361A 7TDD1B080A9451A 7TDD1B100A9451A 8TDD1C100A9481A 8TDD1C100A9541A 8TDD1C120A9541A 9TDD1D120A9601A 9TDD1D140A9601A 9

Performance Data 10

Electrical Data 12

Field Wiring 14

Dimensions 16

Page 4: Downflow/Horizontal Right or Downflow/Horizontal …...2012/06/22  · Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace PUB. NO. 22-1671-10 XR 80 TDD1A040A9241A,

4 22-1671-10

Features andBenefits

• Power supply 115/1/60

• Multi-port In-shot burners

• Integrated solid state control with self-diagnostics

• Silicon Nitride hot surface igniter withadaptive heat up

• Complete front service access

• Heavy gauge aluminized steel heatexchanger

• Slide out blower assembly

• Blower door safety switch

• Direct drive, 4-speed motor

• Optional L.P. conversion kit

• Common vent

• Left and right side knockout for venting

• Selectable cooling fan off delayeliminates need for BAY24X045 timedelay relay

• Quiet slow opening gas valve

• Downflow convertible to horizontal onleft or right side

• Insulated blower compartment

• Accessory hook-up capability –Hum and EAC

• Quiet induced draft blower

• Left/right gas connection

• 24 volt fuse

• Manual reset flame rollout switches

XR 80 Downflow/Horizontal Right or LeftStandard Equipment

Page 5: Downflow/Horizontal Right or Downflow/Horizontal …...2012/06/22  · Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace PUB. NO. 22-1671-10 XR 80 TDD1A040A9241A,

22-1671-10 5

Features andBenefits

Optional EquipmentThermostat ................................................................................................................................................................ BAYSTAT388 [ ]Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) ................................................................................. AY28X092 [ ]Thermostat, Heating/Cooling Single Stage (Mounts Vertically) ................................................................................. BAYSTAT305 [ ]Thermostat, Electronic Programmable 1-Stage Heating/1-Stage Cooling .............................................................. TAYSTAT300C [ ]Propane Conversion Kit ......................................................................................................................................... BAYLPKT210A [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (14-1/2" Wide Gas Furnace) .........................................................TFM145A9FR1 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace) .........................................................TFM175A9FR1 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace) ...............................................................TFM210A9FR1 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace) .........................................................TFM245A9FR1 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace) ................................................ TFP175A9FR01 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace) ...................................................... TFP210A9FR01 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace) ................................................ TFP245A9FR01 [ ]Coil Enclosure (14-1/2" Wide Cabinets) ......................................................................................................... BAYCLE14A1422A [ ]Coil Enclosure (17-1/2" Wide Cabinets) ......................................................................................................... BAYCLE17A1722A [ ]Coil Enclosure (21" Wide Cabinets) ............................................................................................................... BAYCLE21A2130A [ ]Coil Enclosure (24-1/2" Wide Cabinets) ......................................................................................................... BAYCLE24A2430A [ ]Filter Access Door Kit ............................................................................................................................................... BAYFLTR206 [ ]Downflow Subbase .................................................................................................................................................. BAYBASE205 [ ]High Altitude Pressure Switch Kit ............................................................................................................................. BAYHALT248 [ ]

Page 6: Downflow/Horizontal Right or Downflow/Horizontal …...2012/06/22  · Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace PUB. NO. 22-1671-10 XR 80 TDD1A040A9241A,

6 22-1671-10

GeneralData

Product Specifications 1MODEL

TYPE

RATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUETemp. rise (Min.-Max.) °F.

BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz

COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA

FILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)

VENT — Size (in.)

HEAT EXCHANGERType -Fired

-UnfiredGauge (Fired)

ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size

GAS VALVE

PILOT SAFETY DEVICEType

BURNERS — TypeNumber

POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)

PIPE CONN. SIZE (IN.)

DIMENSIONSCrated (In.)

WEIGHTShipping (Lbs.) / Net (Lbs)

TDD1A040A9241A

Downflow / Horizontal

40,00031,00080.0

30 - 60

DIRECT10 x 6

14

See Fan Performance Table1/5

1075115/1/60

CentrifugalDirect - 1

1/50 - 3000115/1/60

1.0

NoHigh Velocity

2 - 14x20 - 1in.

4 Round

Aluminized Steel - Type I

20

2 — 452 — 56

Redundant - Single Stage

Hot Surface Ignition

Multi-port In-shot2

115/1/605.415

1/2

H x W x D41 x 15-1/2 x 29-1/2

119 / 109

TDD1A060A9241A

Downflow / Horizontal

60,00048,00080.0

35 - 65

DIRECT10 x 7

14

See Fan Performance Table1/5

1075115/1/60

CentrifugalDirect - 1

1/50 - 3000115/1/60

1.0

NoHigh Velocity

2 - 14x20 - 1in.

4 Round

Aluminized Steel - Type I

20

3 — 453 — 56

Redundant - Single Stage

Hot Surface Ignition

Multi-port In-shot3

115/1/605.515

1/2

H x W x D41 x 15-1/2 x 29-1/2

129 / 119

TDD1A060A9361A

Downflow / Horizontal

60,00048,00080.0

30 - 60

DIRECT11 x 7

14

See Fan Performance Table1/2

1075115/1/60

CentrifugalDirect - 1

1/50 - 3000115/1/60

1.0

NoHigh Velocity

2 - 14x20 - 1in.

4 Round

Aluminized Steel - Type I

20

3 — 453 — 56

Redundant - Single Stage

Hot Surface Ignition

Multi-port In-shot3

115/1/6011.615

1/2

H x W x D41 x 15-1/2 x 29-1/2

129 / 119

1 Central Furnace heating designs are certified by AGA and CSA.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 ft., derate 4% per 1,000 ft. for elevations above 2,000 ft. above sea level.

For Canadian applications, above input ratings (BTUH) are up to 4,500 ft., derate 4% per 1,000 ft. for elevations above 4,500 ft. above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.

Page 7: Downflow/Horizontal Right or Downflow/Horizontal …...2012/06/22  · Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace PUB. NO. 22-1671-10 XR 80 TDD1A040A9241A,

22-1671-10 7

Product Specifications 1MODEL

TYPE

RATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUETemp. rise (Min.-Max.) °F.

BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz

COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA

FILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)

VENT — Size (in.)

HEAT EXCHANGERType -Fired

-UnfiredGauge (Fired)

ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size

GAS VALVE

PILOT SAFETY DEVICEType

BURNERS — TypeNumber

POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)

PIPE CONN. SIZE (IN.)

DIMENSIONSCrated (In.)

WEIGHTShipping (Lbs.) / Net (Lbs)

GeneralData

TDD1B080A9451A

Downflow / Horizontal

80,00064,00080.0

35 - 65

DIRECT10 x 8

14

See Fan Performance Table1/3

1075115/1/60

CentrifugalDirect - 1

1/50 - 3000115/1/60

1.0

NoHigh Velocity

2 - 16x20 - 1in.

4 Round

Aluminized Steel - Type I

20

4 — 454 — 56

Redundant - Single Stage

Hot Surface Ignition

Multi-port In-shot4

115/1/609.815

1/2

H x W x D41 x 18-1/2 x 29-1/2

146 / 135

TDD1B080A9361A

Downflow / Horizontal

80,00064,00080.0

35 - 65

DIRECT10 x 7

14

See Fan Performance Table1/3

1075115/1/60

CentrifugalDirect - 1

1/50 - 3000115/1/60

1.0

NoHigh Velocity

2 - 14x20 - 1in.

4 Round

Aluminized Steel - Type I

20

4 — 454 — 56

Redundant - Single Stage

Hot Surface Ignition

Multi-port In-shot4

115/1/609.015

1/2

H x W x D41 x 18-1/2 x 29-1/2

146 / 135

1 Central Furnace heating designs are certified by AGA and CSA.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 ft., derate 4% per 1,000 ft. for elevations above 2,000 ft. above sea level.

For Canadian applications, above input ratings (BTUH) are up to 4,500 ft., derate 4% per 1,000 ft. for elevations above 4,500 ft. above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.

TDD1B060A9361A

Downflow / Horizontal

60,00048,00080.0

30 - 60

DIRECT10 x 7

14

See Fan Performance Table1/3

1075115/1/60

CentrifugalDirect - 1

1/50 - 3000115/1/60

1.0

NoHigh Velocity

2 - 14x20 - 1in.

4 Round

Aluminized Steel - Type I

20

3 — 453 — 56

Redundant - Single Stage

Hot Surface Ignition

Multi-port In-shot3

115/1/6011.615

1/2

H x W x D41 x 18-1/2 x 29-1/2

134 / 124

Page 8: Downflow/Horizontal Right or Downflow/Horizontal …...2012/06/22  · Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace PUB. NO. 22-1671-10 XR 80 TDD1A040A9241A,

8 22-1671-10

GeneralData

Product Specifications 1MODEL

TYPE

RATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUETemp. rise (Min.-Max.) °F.

BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz

COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA

FILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)

VENT — Size (in.)

HEAT EXCHANGERType -Fired

-UnfiredGauge (Fired)

ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size

GAS VALVE

PILOT SAFETY DEVICEType

BURNERS — TypeNumber

POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)

PIPE CONN. SIZE (IN.)

DIMENSIONSCrated (In.)

WEIGHTShipping (Lbs.) / Net (Lbs)

1 Central Furnace heating designs are certified by AGA and CSA.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 ft., derate 4% per 1,000 ft. for elevations above 2,000 ft. above sea level.

For Canadian applications, above input ratings (BTUH) are up to 4,500 ft., derate 4% per 1,000 ft. for elevations above 4,500 ft. above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.

TDD1C100A9481A

Downflow / Horizontal

100,00080,00080.0

35 - 65

DIRECT10 x 8

14

See Fan Performance Table1/2

1075115/1/60

CentrifugalDirect - 1

1/50 - 3000115/1/60

1.0

NoHigh Velocity

2 - 16x20 - 1in.

4 Round

Aluminized Steel - Type I

20

5 — 455 — 56

Redundant - Single Stage

Hot Surface Ignition

Multi-port In-shot5

115/1/6011.615

1/2

H x W x D41 x 22 x 29-1/2

166 / 154

TDD1C100A9541A

Downflow / Horizontal

100,00081,00080.0

30 - 60

DIRECT11 x 10

14

See Fan Performance Table1/2

1075115/1/60

CentrifugalDirect - 1

1/50 - 3000115/1/60

1.0

NoHigh Velocity

2 - 14x20 - 1in.

4 Round

Aluminized Steel - Type I

20

5 — 455 — 56

Redundant - Single Stage

Hot Surface Ignition

Multi-port In-shot5

115/1/6013.420

1/2

H x W x D41 x 22 x 29-1/2

167 / 155

TDD1B100A9451A

Downflow / Horizontal

100,00080,00080.0

35 - 65

DIRECT10 x 8

14

See Fan Performance Table1/3

1075115/1/60

CentrifugalDirect - 1

1/50 - 3200115/1/60

1.0

NoHigh Velocity

2 - 16x20 - 1in.

4 Round

Aluminized Steel - Type I

20

5 — 455 — 56

Redundant - Single Stage

Hot Surface Ignition

Multi-port In-shot5

115/1/609.815

1/2

H x W x D41 x 18-1/2 x 29-1/2

156 / 145

Page 9: Downflow/Horizontal Right or Downflow/Horizontal …...2012/06/22  · Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace PUB. NO. 22-1671-10 XR 80 TDD1A040A9241A,

22-1671-10 9

Product Specifications 1MODEL

TYPE

RATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUETemp. rise (Min.-Max.) °F.

BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz

COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA

FILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)

VENT — Size (in.)

HEAT EXCHANGERType -Fired

-UnfiredGauge (Fired)

ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size

GAS VALVE

PILOT SAFETY DEVICEType

BURNERS — TypeNumber

POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)

PIPE CONN. SIZE (IN.)

DIMENSIONSCrated (In.)

WEIGHTShipping (Lbs.) / Net (Lbs)

GeneralData

TDD1D140A9601A

Downflow / Horizontal

140,000113,000

80.045 - 75

DIRECT11 x 10

14

See Fan Performance Table3/4

1075115/1/60

CentrifugalDirect - 1

1/50 - 3000115/1/60

1.0

NoHigh Velocity

2 - 16x20 - 1in.

4 Round

Aluminized Steel - Type I

20

7 — 457 — 56

Redundant - Single Stage

Hot Surface Ignition

Multi-port In-shot7

115/1/6013.820

1/2

H x W x D41 x 25_-1/2 x 28

196 / 183

TDD1D120A9601A

Downflow / Horizontal

120,00096,00080.0

35 - 65

DIRECT11 x 10

14

See Fan Performance Table1/2

1075115/1/60

CentrifugalDirect - 1

1/50 - 3000115/1/60

1.0

NoHigh Velocity

2 - 16x20 - 1in.

4 Round

Aluminized Steel - Type I

20

6 — 456 — 56

Redundant - Single Stage

Hot Surface Ignition

Multi-port In-shot6

115/1/6013.420

1/2

H x W x D41 x 25-1/2 x 29-1/2

189 / 176

1 Central Furnace heating designs are certified by AGA and CSA.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 ft., derate 4% per 1,000 ft. for elevations above 2,000 ft. above sea level.

For Canadian applications, above input ratings (BTUH) are up to 4,500 ft., derate 4% per 1,000 ft. for elevations above 4,500 ft. above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.

TDD1C120A9541A

Downflow / Horizontal

120,00096,00080.0

35 - 65

DIRECT11 x 10

14

See Fan Performance Table1/2

1075115/1/60

CentrifugalDirect - 1

1/50 - 3000115/1/60

1.0

NoHigh Velocity

2 - 16x20 - 1in.

4 Round

Aluminized Steel - Type I

20

6 — 456 — 56

Redundant - Single Stage

Hot Surface Ignition

Multi-port In-shot6

115/1/6013.420

1/2

H x W x D41 x 22 x 29-1/2

170 / 158

Page 10: Downflow/Horizontal Right or Downflow/Horizontal …...2012/06/22  · Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace PUB. NO. 22-1671-10 XR 80 TDD1A040A9241A,

10 22-1671-10

PerformanceData

FURNACE AIRFLOW (CFM) VS. STATIC PRESSURE (ins. w.g.)

MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90

*DD1A040A9241A

4 -3 -2 -1 -

HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red

1070870740633

1033850720600

1000823690577

960790663543

920753627507

860813588463

810667547420

740613483360

-490

--

*DD1A060A9241A

4 -3 -2 -1 -

HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red

12001025838722

1155988808689

1111951779656

1056905742618

1001859704579

924797646528

848735588478

774646502376

701558415275

*DD1A060A9361A

*DD1B060A9361A

4 -3 -2 -1 -

HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red

148013021115956

142912761100947

137512291070918

131811881035888

128211411000859

11001088965824

11121024918788

1029953859741

959882790682

*DD1B080A9361A

4 -3 -2 -1 -

HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red

152313171123942

149613071119943

146312611106931

142012421082920

136912231056898

131011751016868

12431122976833

11721060930795

11001000880760

*DD1B080A9451A

4 -3 -2 -1 -

HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red

1798138412101005

175013671150970

169213331108808

164213001075775

157512751042767

150012331008733

14251192967700

13251142925675

12251083867617

*DD1B100A9451A

4 -3 -2 -1 -

HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red

176713821130840

173113541138831

166913231115815

161512921085792

154612541054762

146912071015731

13921177977700

13001108938654

11461038877625

*DD1C100A9481A

4 -3 -2 -1 -

HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red

1965164514071202

1915162713981208

1865160513871205

1805157513751195

1740153513471166

1670148213181140

1587142112751105

1500133011901045

137012201095970

*DD1B100A9541A

4 -3 -2 -1 -

HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red

2165196217051492

2113192716881467

2060189116711442

1995183916361414

1929178616001385

1842172415471346

1755166214921307

1674158114351243

1593150013771179

*DD1C120A9541A

4 -3 -2 -1 -

HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red

2100191716721485

2049188716561478

1997185716391470

1958184216311448

1918182716231426

1852175115601388

1785167414961349

1695159414271278

1604151413581207

*DD1D120A9601A

4 -3 -2 -1 -

HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red

2241198117211476

2202196217051466

2163194216881456

2106190416711440

2049186616531423

1979180516111392

1908174315691361

1804168015151302

1700161714611243

*DD1D140A9601A

4 -3 -2 -1 -

HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red

2377211518061527

2321208117931507

2265204617791486

2199199217381473

2133193816961459

2050187216551422

1967180516141384

1877172715561329

1786164914971273

* May be "A" or "T"

Page 11: Downflow/Horizontal Right or Downflow/Horizontal …...2012/06/22  · Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace PUB. NO. 22-1671-10 XR 80 TDD1A040A9241A,

22-1671-10 11

PerformanceData

CFM VS. TEMPERATURE RISE

MODELCubic Feet Per Minute (CFM)

500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400

TDD1A040A9241A 59 49 42 37 33 30

TDD1A060A9241A 63 56 49 44 40

TDD1A060A9361A 56 49 44 40 37 34 32

TDD1B060A9361A 56 49 44 40 37 34 32

TDD1B080A9361A 59 54 59 46 42

TDD1B080A9451A 64 57 52 48 44 41

TDD1B100A9451A 62 57 53 49 46 44 41

TDD1C100A9481A 62 57 53 49 46 44 41 39 37

TDD1C100A9451A 62 57 53 49 46 44 41 39 37 35 34 32 31

TDD1C120A9541A 59 56 52 49 47 44 42 40

TDD1D120A9601A 59 56 52 49 47 44 42 40

TDD1D140A9601A 69 65 61 58 55 52 49 47 45

Page 12: Downflow/Horizontal Right or Downflow/Horizontal …...2012/06/22  · Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace PUB. NO. 22-1671-10 XR 80 TDD1A040A9241A,

12 22-1671-10

(continued on next page)

WIRING DIAGRAM

From Dwg. D342568P01 Rev. 1

Page 13: Downflow/Horizontal Right or Downflow/Horizontal …...2012/06/22  · Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace PUB. NO. 22-1671-10 XR 80 TDD1A040A9241A,

22-1671-10 13

SCHEMATIC DIAGRAM

From Dwg. D342568P01 Rev. 1

Page 14: Downflow/Horizontal Right or Downflow/Horizontal …...2012/06/22  · Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace PUB. NO. 22-1671-10 XR 80 TDD1A040A9241A,

14 22-1671-10

FieldWiring

FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING ONLY

FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING/COOLING(OUTDOOR SECTION WITHOUT TRANSFORMER)

From Dwg. 21B341437 Rev. 1

From Dwg. 21B341436 Rev. 1

Page 15: Downflow/Horizontal Right or Downflow/Horizontal …...2012/06/22  · Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace PUB. NO. 22-1671-10 XR 80 TDD1A040A9241A,

22-1671-10 15

Dimensions

FieldWiring

From Dwg. 21B341423 Rev. 1

From Dwg. 21B341422 Rev. 1

Page 16: Downflow/Horizontal Right or Downflow/Horizontal …...2012/06/22  · Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace PUB. NO. 22-1671-10 XR 80 TDD1A040A9241A,

Trane6200 Troup HighwayTyler, TX 75707www.trane.com

Since The Trane Company has a policy of continuous product and product dataimprovement, it reserves the right to change design and specifications withoutnotice.

Literature Order Number 22-1671-10

File Number 22-1671-10

Supersedes 22-1671-09

Date 06/10

Fro

m D

wg.

21C

3417

00 R

ev. 0

TDD

1 O

UTL

INE

DR

AW

ING

(ALL

DIM

EN

SIO

NS

AR

E IN

INC

HE

S)

MO

DE

LD

IM "

A"

DIM

"B

"D

IM "

C"

DIM

"D

"

*DD

1A04

0A92

41A

*DD

1A06

0A92

41A

*DD

1A06

0A93

61A

14-1

/2"

9-5/

8"13

-1/4

"13

"

*DD

1B06

0A93

61A

*DD

1B08

0A93

61A

*DD

1B08

0A94

51A

*DD

1B10

0A94

51A

17-1

/2"

9-5/

8"16

-1/4

"16

"

*DD

1C10

0A94

81A

*DD

1C10

0A95

41A

*DD

1C12

0A95

41A

21"

13-1

/16"

19-3

/4"

19-1

/2"

*DD

1D12

0A96

01A

*DD

1D14

0A96

01A

24-1

/2"

15-5

/16"

23-1

/4"

23"

* P

RE

FIX

LE

TT

ER

MAY

BE

"A

" O

R "

T"


Recommended