Cavitron™ JET Combination System UltrasonicScaler and Air Polishing Prophylaxis System

Directions For Use

Veuillez lire soigneusement et complètement avant d’utiliser le système.

Por favor lea la totalidad de las instrucciones cuidadosamente antes de hacer funcionar la unidad.

Système combiné Cavitron™ JET Détartreur ultrasonique et système deprophylaxie par polissage à l’air

Mode d’emploi

Sistema combinado Cavitron™ JETEscarificador ultrasónico y unidad profiláctica de pulido neumático

Instrucciones para el uso

Page 2: Cavitron JET Combination System Ultrasonic Scaler … Manual for... · ENGLISH • 1 ENGLISH Cavitron™ JET Combination System Ultrasonic Scaler and Air Polishing Prophylaxis System

ENGLISH • 1

ENGLISH

Cavitron™ JET Combination System UltrasonicScaler and Air Polishing Prophylaxis System

Introduction

Directions For Use

DENTSPLY® Preventive Care is an ISO9001 and EN46000certified company. The Cavitron™ JET Combination System isclassified by Underwriters Laboratories Inc. with respect to electricshock, fire, mechanical hazards only in accordance UL 2601-1and Can/CSA C22.2 NO. 601, assigned control # 13VA.

The Cavitron™ JET dental prophylaxis system is a precisionengineered and manufactured instrument. It contains controlsand components for ultrasonic scaling and air polishing modes.

The System operates by converting ordinary AC house currentinto high frequency current. The ultrasonic system consists oftwo parts: an insert, and the SPS (Sustained PerformanceSystem™) electronic system. The SPS™ system incorporates twoclosed loops. One provides automatic tuning (operating frequencyis adjusted to be at resonance for each insert), the second loopautomatically controls the tip stroke over different workingconditions. The Cavitron™ JET Combination System produces30,000 microscopically small strokes per second at the insert’sworking tip. This combined with acoustic effects of the coolantwater, produces a synergistic action that literally “powers away”the heaviest calculus deposits while providing exceptionaloperator and patient comfort.

With the addition of the Air Polishing function, your Cavitron™

JET becomes a complete prophylaxis system. Mode selection isautomatic when you place the Airpolishing insert nozzle or one ofthe interchangeable 30K™ ultrasonic inserts into the handpiece.

Technical Support

There are no serviceable parts in this device. Refer all service to aqualified service repair facility. For technical support and repairassistance in the U.S. call 1-800-347-7412 Monday throughFriday, 8:00 AM to 5:00 PM (Eastern Time). For other areas,contact your local DENTSPLY representative.

Supplies & Replacement Parts

To order supplies or replacement parts for your Cavitron™ JETCombination System, contact your local DENTSPLY® Dealer. Ifyour dealer is unable to assist you, call 1-800-989-8826 Mondaythrough Friday, 8:00 AM to 5:00 PM (Eastern Time). For otherareas, contact your local DENTSPLY® representative.

Caution: U.S. Federal Law restricts this device to sale by or on theorder of a dentist.

Cavitron™ JET

Combination System

Ultrasonic Scaler and Air Polishing

Prophylaxis System

Please read carefully and completely before operating unit.

Page 3: Cavitron JET Combination System Ultrasonic Scaler … Manual for... · ENGLISH • 1 ENGLISH Cavitron™ JET Combination System Ultrasonic Scaler and Air Polishing Prophylaxis System

ENGLISH • 2

Table of ContentsSection Section Title PageNumber Description of Contents Number

1 Indications ............................................................................................................................................................ 31.1 Ultrasonic procedures1.2 Air Polishing procedures

2 Contraindications and Warnings .......................................................................................................................... 32.1 Contraindications2.2 Warnings

3 Precautions ....................................................................................................................................................... 3-43.1 Precautions for All Systems3.2 Precautions for Ultrasonic Prophylaxis Procedures3.3 Precautions for Airpolishing Procedures

4 Infection Control .................................................................................................................................................. 44.1 Infection Control Information Reference Card4.2 General Infection Control Recommendations4.3 Water Supply Recommendations

5 Installation Instructions .................................................................................................................................... 4-65.1 General Information5.2 Water Line Requirements5.3 Air Line Requirements and Recommendations5.4 Electrical Requirements5.5 Unpacking the System5.6 Power Cord/Power Connection5.7 Foot Control Cable Assembly Connection5.8 Incoming Water Supply Line Connection5.9 Air Supply Line Connection

6 Cavitron™ JET Combination System Ultrasonic Scaler and Air Polishing Prophylaxis System .......................... 6-86.1 System Controls6.2 Handpiece6.3 Cavitron® 30K™ Ultrasonic Inserts6.4 Cavitron™ JET Air Polishing Insert Nozzle6.5 Foot Control Information and Operation6.6 Operation for Ultrasonic Prophylaxis Prodedures6.7 Operation for Air Polishing Prodedures

7 Accessories ............................................................................................................................................................ 97.1 Accessories List

8 Techniques for Use ......................................................................................................................................... 9-128.1 General Information on Patient Positioning8.2 Performing Ultrasonic Scaling Procedures8.3 Patient Comfort Considerations8.4 Air Polishing Powder Chamber8.5 Air Polishing using the JetShield™ Accessory8.6 Performing JET Air Polishing Procedures with JetShield™8.7 Performing Air Polishing Procedures without JetShield™8.8 Proper Angulation of the Air Polishing Insert without JetShield™

9 System Care .................................................................................................................................................. 13-149.1 Daily Maintenance —Start-Up Procedures, Between Patients, Shut-Down Procedures9.2 Periodic Maintenance

10 Troubleshooting ................................................................................................................................................ 1410.1 Troubleshooting10.2 Technical Support and Repairs

11 Specifications ..................................................................................................................................................... 1512 Classifications .................................................................................................................................................... 15

Page 4: Cavitron JET Combination System Ultrasonic Scaler … Manual for... · ENGLISH • 1 ENGLISH Cavitron™ JET Combination System Ultrasonic Scaler and Air Polishing Prophylaxis System

ENGLISH • 3

Section 1: Indications

Section 2: Contraindications and Warnings

Section 3: Precautions

3.1 Precautions for All Systems

Ultrasonics

• Do not place the System on or next to a radiator or otherheat source. Excessive heat may damage the System’selectronics. Place the System where air is free to circulateon all sides and beneath it.

• The System is portable, but must be handled with carewhen moving.

• Equipment flushing and dental water supply systemmaintenance are strongly recommended. See Water

Supply under Section 9: System Care.

• Close the coolant water shut-off valve to the System everynight before leaving the office. The use of an in-line waterfilter is recommended.

2.1 Contraindications

• Ultrasonic Systems should not be used for restorativedental procedures involving the condensation ofamalgam.

• For best performance, use only ultrasonic insertsmanufactured by Dentsply® Preventive Care.

• Use only Cavitron® Prophy-Jet® Cleaning Powder.

1.1 Ultrasonic procedures

• All general supra and subgingival scaling applications.

• Periodontal debridement for all types of periodontaldiseases.

• For patients with a history of sensitivity to ultrasonics.

• Endodontic procedures.

2.2 Warnings

• Persons fitted with cardiac pacemakers have beencautioned that some types of electronic equipment mightinterfere with the operation of a pacemaker. Although noinstance of pacemaker interference has ever been reportedto DENTSPLY®, we recommend that the handpiece andcables be kept at least 6 to 9 inches (15 to 23 cm) awayfrom any pacemaker and pacemaker leads during use.

• Do not direct the air polishing stream at soft tissue orinto the sulcus. Tissue emphysema has been reportedlycaused when the air/water/powder stream was directedat the soft tissues or into the sulcus.

Air Polishing

• The use of an air dryer on the compressor line supplyingthe System will prevent condensation from forming inthe air line which in turn may cause “caking” of the airpolishing cleaning powder and clogging the lines at theair polishing tip.

• Cavitron® Prophy-Jet® Cleaning Powder is a water-solublesodium bicarbonate powder specially formulated for use in

1.2 Air polishing procedures:

• Removal of a variety of extrinsic stains, e.g., tobacco,coffee & tea, chlorhexidine.

• Prophylaxis of orthodontic patients.

• Preparing tooth surfaces prior to bonding and sealantprocedures.

3.2 Precautions for Ultrasonic ProphylaxisProcedures

• Like a toothbrush, ultrasonic inserts “wear out” withuse. Inserts with just 2 mm of wear lose about 50% oftheir scaling efficiency. In general, it is recommended thatultrasonic inserts be discarded and replaced after 2 mm ofwear to maintain optimal efficiency and avoid breakage.

• If excessive wear is noted, or the insert has been bent,reshaped or otherwise damaged, discard the insertimmediately.

• Ultrasonic insert tips that have been bent, damaged, orreshaped are susceptible to in-use breakage and shouldbe discarded and replaced immediately.

• Retract the lips, cheeks and tongue to prevent contactwith the insert tip whenever it is placed in the patient’smouth.

Cavitron® Air Polishing Systems. Do not attempt to useany other cleaning materials in the air polishing powderreservoir.

• Empty the air polishing powder reservoir at the end ofthe day to prevent “caking” of the powder and cloggingthe lines and air polishing tip.

Page 5: Cavitron JET Combination System Ultrasonic Scaler … Manual for... · ENGLISH • 1 ENGLISH Cavitron™ JET Combination System Ultrasonic Scaler and Air Polishing Prophylaxis System

ENGLISH • 4

Section 4: Infection Control

4.1 Infection Control InformationReference Card

For your convenience, an Infection Control Information referencecard, printed on durable stock, has been included with yourCavitron™ JET Combination System. If your card is missing ormisplaced, you can request a replacement in the U.S. by callingCustomer Service at 1-800-989-8826 Monday through Friday,8:00 AM to 5:00 PM (Eastern Time) For other areas, contactyour local DENTSPLY representative.

4.2 General Infection ControlRecommendations

• As with all dental procedures, use standard personalprotection equipment (i.e., wear face mask, eyewear or faceshield, gloves and protective gown).

4.3 Water Supply Recommendations

It is highly recommended that all dental water supply systemsconform to applicable CDC (U.S. Centers for Disease Controland Prevention) and ADA (American Dental Association)standards, and that all recommendations be followed in terms offlushing, chemical flushing, and general infection controlprocedures. See sections 4.2 and 9.

Section 3: Precautions cont'd

3.3 Precautions for Air Polishing Procedures

• Only set the air polishing powder flow control to themaximum position (H) when it is necessary to removeparticularly difficult stains. Return the powder flowcontrol to the medium position upon the completion ofthe procedure.

• Avoid prolonged or excessive use on restorative dentalmaterials.

• As with high speed handpieces, and other dental devices,the combination of water and ultrasonic vibration fromyour Cavitron™ JET Combination System will createaerosols. With proper technique, much of the Cavitron™

JET Combination System’s aerosol dispersion can beeffectively controlled and minimized. Please carefullyfollow the procedural guidelines in this manual regardingthe use of your System.

• For maximal operator and patient safety, carefully followthe Infection Control Information procedures detailedon the reference card accompanying your System.

• Avoid prolonged use on cementum or dentin.

• Avoid prolonged use on polished metal surfaces as amatte finish may result.

• Patients who are on a restricted sodium diet, or havesevere respiratory illness, should consult their physicianbefore undergoing air polishing prophylaxis procedures.

• Patients wearing contact lenses should remove themprior to air polishing treatment.

Section 5: Installation Instructions

5.1 General Information

If the installation of your Cavitron™ JET Combination System isperformed by someone other than trained DENTSPLY® Dealerpersonnel, care should be taken to observe the following require-ments and recommendations.

5.2 Water Line Requirements

• The System’s water supply line is factory installed. Donot disconnect from the System.

• Incoming water supply line pressure to the System mustbe 25 psi (172 kPa) to 60 psi (414kPa). If your dentalwater system’s supply line pressure is above 60 psi(414 kPa), install a water pressure regulator on the supplyline to your Cavitron™ JET Combination System.

• A manual shut-off valve on the dental water systemsupply line should be used so that the water can becompletely shut-off when the office is unoccupied.

• A filter in the dental water system supply line is recom-mended so that any particulates in the water supply willbe trapped before reaching the System.

• After the above installations are completed on the dentalwater supply system, the dental office water line shouldbe thoroughly flushed prior to connection to the System.

Page 6: Cavitron JET Combination System Ultrasonic Scaler … Manual for... · ENGLISH • 1 ENGLISH Cavitron™ JET Combination System Ultrasonic Scaler and Air Polishing Prophylaxis System

ENGLISH • 5

5.3 Air Line Requirements &Recommendations

• An air supply line is factory installed on Cavitron™ JETCombination System. Do not disconnect it.

• Incoming air supply line pressure to the System must be65 psig (448kPa) to 100 psig (690kPa). If your office airline pressure is above 100 psig (690kPa), install an airpressure regulator on the supply line to your Cavitron™

JET Combination System.

• A manual shut-off valve on the office air supply lineshould be used so that the air line can be completelyshut-off, and the line pressure relieved when the office isunoccupied.

• Your System must be supplied with clean, dry air. Tohelp prevent water condensation from forming in the airsupply line which may cause the system to malfunction, itis strongly recommended that an air dryer be used on thecompressor line supplying the System.

5.4 Electrical Requirements

Refer to Section 11: Specifications.

5.7 Foot Control Cable AssemblyConnection

Align the Foot Control plug with the receptacle on the back ofthe System and push it in until firmly seated.

5.5 Unpacking the System

Carefully unpack your Cavitron™ JET Combination System andverify that all components and accessories are included:

1. Cavitron™ JET Combination System with watersupply line, air supply line, handpiece and cableconnector assembly factory installed.

2. Air filter assembly.

3. Detachable AC Power Cord set.

4. Cavitron™ JET Insert Nozzle with cleaning tool.

5. Dual position Foot Control Assembly.

6. Cavitron® Ultrasonic Inserts (quantity optional).

7. Efficiency Indicator for Cavitron® Inserts.

8. JetShield™ Aerosol Reduction Device.

9. Literature Packet.

ON/OFF rocker switch

Section 5: Installation Instructions cont'd

5.6 Power Cord/Power Connection

• Verify the Power Control ON/OFF rocker switch locatedat the left front underside of the System is set to the OFFposition before proceeding.

• Plug the detachable AC cord into the back of the System.

• Plug the 3 prong grounded plug into an approved outlet.

Page 7: Cavitron JET Combination System Ultrasonic Scaler … Manual for... · ENGLISH • 1 ENGLISH Cavitron™ JET Combination System Ultrasonic Scaler and Air Polishing Prophylaxis System

ENGLISH • 6

6.1 System Controls

Top GroovesProvide a convenient, temporary place-

ment for the handpiece during treatmentprocedures. Always place handpiece inholder when not being used.

Power AdjustmentTurn knob to select ultrasonicpower level for operation:clockwise increases system

power, counter clockwisedecreases system power.NOTE: For Air Polishing, set

the power level betweenmedium (mid) and maximum.

HandpieceHolds all Cavitron® 30K™Ultrasonic Inserts and transmitspower and lavage from the

System to the insert. It also holdsthe Cavitron™ JET insert nozzlewhich automatically selects air

polishing mode.

Section 5: Installation Instructions cont'd

5.8 Water Supply Line Connection

• Connect the free end of the system’s water supply line tooffice water supply line or a Cavitron® DualSelect™Dispensing System.

• Inspect all connections to make certain there are no leaks.

5.9 Air Supply Line Connection

• Connect the free end of the system’s air supply line tooffice air supply line or a Cavitron™ DualSelect™

dispensing System.

• Inspect all connections to make certain there are no leaks.

Section 6: Cavitron™ Jet Combination System UltrasonicScaler and Air Polishing Prophylaxis SystemDescription

AC Power Indicator LightLighted when System is

switched ON.

Power ControlON/OFF switch located at the leftfront underside of the System.

Boost Indicator LightThe two-position Foot Control provides thecapability to increase the front panel Powerdial setting. When lighted, indicates FootControl is fully depressed, and System is

functioning in "Boost" mode.

Lavage Flow AdjustmentTurn knob to select Lavage Flow level during System operation.Clockwise increases flow at insert tip, counter clockwise decreases flow.

The rate of flow through the Handpiece determines the temperature of thelavage. Low flow rates produce warmer temperatures, higher flow ratesproduce cooler temperatures.

Powder Fill CapRemovable cap for filling and emptying thepowder chamber. An adjustable pointer

increases or decreases powder flow rates.

Handpiece HolderSecurely holds the System'sHandpiece when system isnot being used.

Page 8: Cavitron JET Combination System Ultrasonic Scaler … Manual for... · ENGLISH • 1 ENGLISH Cavitron™ JET Combination System Ultrasonic Scaler and Air Polishing Prophylaxis System

ENGLISH • 7

Section 6: Cavitron™-Jet Combination System Ultrasonic Scalerand Air Polishing Prophylaxis System cont'd

O-RingProvides seal for handpiececoolant.

Insert TipShape and size of tip determines access andadaptation. Preheated Lavage directed to

tip.

Finger Grip

Connecting BodyTransfers and amplifies mechanicalmotion of stack to insert tip.

6.3 Cavitron® 30K™ Ultrasonic Inserts

The many styles of Cavitron® 30K™ Ultrasonic Inserts are easily interchangeablefor various procedures and applications. See enclosed booklet for specific information.

Hold the handpiece in an upright position. Activate to bleed any air bubbles that might be trapped inside the handpiece. Lubricate therubber O-ring on the insert with water before placing it into the handpiece. Fully seat insert with a gentle push-twist motion. DO NOTFORCE.

6.4 Cavitron™ JET Air Polishing Insert nozzle

The Air Polishing Insert Nozzle automatically selects the JET mode when placed in handpiece.

Cleaning Powder Delivery Tube: Directsair/powder flow to insert tip.

Insert Heater Rod: Heats the

delivered water for patientcomfort.

O-Ring: Seals water when Insert Nozzle isfully seated in Handpiece.

Air Polishing Insert Tip:

Tube-in-a-tube designdeliveres preciseair/water/powder mixture

at point of delivery.

6.2 Handpiece

The handpiece accepts all Cavitron® 30K™ Ultrasonic Inserts and the JET air polishing insert nozzle. The open end of the handpieceaccepts all Cavitron® 30K™ inserts.

Insert Port

Air Polishing Powder Delivery Port

Powder Flow WindowHandpiece

Cable

Magnetostrictive StackConverts energy provided by the hand-piece into mechanical oscillations

used to activate the insert tip.

Insert MarkingManufacturer, Date (YYMM),

Frequency, Type.E.g. DENTSPLY 9608 30K FSI-SLI-10S

Lubricate the rubber O-ring on the insert with water before placing it into the handpiece. Place the heater rod into the insert port of thehandpiece. Align the powder delivery tube with the powder delivery port and gently push into handpiece until fully seated.

Page 9: Cavitron JET Combination System Ultrasonic Scaler … Manual for... · ENGLISH • 1 ENGLISH Cavitron™ JET Combination System Ultrasonic Scaler and Air Polishing Prophylaxis System

ENGLISH • 8

Section 6: Cavitron™-Jet Combination System Ultrasonic Scaler andAir Polishing Prophylaxis System cont'd

6.5 Foot Control Information & Operation

The Foot Control is a two-position momentary switch, whichactivates both ultrasonic energy and Lavage Flow at the insert tip.

6.6 Operation for Ultrasonic Prophylaxis Procedures

No ultrasonic energy or lavage flow.Ultrasonics and lavage floware activated

Foot control

depressed all theway.

6.7 Operation for Air Polishing Procedures

Foot controldepressed half way.

Foot controlreleased.

Boost function is activated.

Bleed air exits insert

nozzle tip.

Foot controldepressed

half way.

Foot control

released.

Lavage flow(rinsing function)is activated.

Air PolishingFunction is activated.

Foot controldepressed

all the way.

Page 10: Cavitron JET Combination System Ultrasonic Scaler … Manual for... · ENGLISH • 1 ENGLISH Cavitron™ JET Combination System Ultrasonic Scaler and Air Polishing Prophylaxis System

ENGLISH • 9

Section 7: Accessories

Section 8: Techniques for Use

8.1 Patient Positioning

• For optimal access to both the upper and lower arches,the backrest of the chair should be adjusted as for otherdental procedures. This assures patient comfort andclinician visibility.

7.1 Accessories List*

1. AC Power Cord Set

2. Cavitron® Ultrasonic Inserts

3. Cavitron™ Jet Insert Nozzle

4. Dual position Foot Switch Assembly

5. DualSelect™ Medicament Dispensing System

6. JetShield™ Aerosol Reduction Device

*For detailed information, contact your local DENTSPLY® Representative.

• Have the patient turn their head to the right or left. Alsoposition their chin up or down depending upon thequadrant and surface being treated. Evacuate irrigantusing either a saliva ejector or HVE.

8.2 Performing Ultrasonic ScalingProcedures

NOTE: Refer to the Infection Control Information card (Formno. 80722) supplied with your Unit for general procedures to befollowed at the beginning of each day and between patients.

• The edges of Cavitron® Ultrasonic Inserts are intention-ally rounded so there is little danger of tissue lacerationwith proper ultrasonic scaling technique. Whenever theinsert tip is placed within the patient’s mouth, the lips,cheek and tongue should be retracted to prevent acciden-tal prolonged contact with the activated tip.

• Hold the empty Handpiece in an upright position andactivate the Foot Control until fluid exits.

• Lubricate the rubber O-ring on the insert with waterbefore placing it into the handpiece. Fully seat insert witha gentle push-twist motion. DO NOT FORCE.

• Set the Unit’s Power Adjustment knob to the lowestpower setting for the application and the selected insert.

• Activate the Foot Control and hold the Handpiece over asink or drain. Check spray temperature to verify fluid isreaching the working end of the insert tip. Adjust theLavage flow knob to ensure adequate flow for theselected Power setting. Greater flow settings providecooler irrigant.

• It may be necessary to adjust lavage with the System in“Boost” mode (Foot Control fully depressed) soadequate fluid will be available to cool tip, tooth interface.

• In general, it is suggested that a “feather-light-touch” beused both supra- and subgingivally. The motion of theactivated tip and acoustic effects in the irrigating fluid, inmost cases, is adequate to remove even the mosttenacious calculus.

• Use Cavitron® efficiency indicator if an insert seems torequire increased finger pressure to function adequately.

• The use of a saliva ejector or HVE is recommendedduring all procedures.

8.3 Patient Comfort Considerations

Reasons for sensitivity

1. Incorrect tip placement. Point should be directed awayfrom root surfaces.

2. Not keeping tip in motion on tooth. Do not allow theinsert to remain in a static position on any one area ofthe tooth. Change the insert’s path of motion.

3. Applying pressure. Use extremely light grasp andpressure, especially on exposed cementum.

4. If sensitivity persists, decrease power setting and/ormove from the sensitive tooth to another and thenreturn.

Page 11: Cavitron JET Combination System Ultrasonic Scaler … Manual for... · ENGLISH • 1 ENGLISH Cavitron™ JET Combination System Ultrasonic Scaler and Air Polishing Prophylaxis System

ENGLISH • 10

8.5 Air Polishing using the JetShield™Accessory

Aerosol reduction device for use with air polishing systems.

JetShield™ assembly and accessories – see Fig. 1. The disposableJetShield™ assembly is designed for single use; all other compo-nents are reusable and are compatible with standard clinicequipment.

B. JetShield™assembly

F. Connector

C. Connector

D. Handpiece clip

E. Ejector tube clip

A. Ejector tube������� �

Precautions:

The JetShield™ itself is designed for single use only. Use ofchemical or heat sterilization will lead to poor performance andmalfunction of product.

Section 8: Techniques for Use cont'd

8.4 Air Polishing Powder Chamber

• Use only Cavitron® Prophy-Jet® Cleaning Powder in yourCavitron™ Jet Combination System. Any other sub-stances or additives may clog the Unit and will void thewarranty. For your convenience, the cleaning powder issupplied in sealed packets. Keep packets dry andstored in a location that does not exceed 95o F.

• A special container is provided with your System forpowder filling and storage. The opening in thecontainer’s fill cap permits easy filling of the powderchamber. An additional cap without a hole is providedfor storage.

• It is strongly recommended that the Powder Chamber beemptied at the end of each day. This will reduce moistureabsorption and minimize clogging.

To fill, or refill, the powder chamber:

• Turn the Unit OFF.

• Unscrew the Powder Fill Cap.

• Transfer the powder from the packet into the fillcontainer and screw on fill cap.

• Place finger over hole and shake the powder containervigorously to break up any lumps that may have formedfrom settling. Carefully pour powder into the chamberuntil the level reaches the top of the center tube.

• Replace the Chamber Powder Fill Cap and tighten.

• Turn the Unit ON.

NOTE: Use only Cavitron® Prophy-Jet® Cleaning Powder in theunit. Prophy-Jet® Cleaning Powder should be kept dry and storedin a location that does not exceed 95° F.

To adjust the flow of powder:

• Adjust the powder flow rate by positioning the controlat H(12 O’clock), M(9 O’clock), or L(6 O’clock).

• For heavy stain removal set the control on “H.”

• For light stain removal set the control on “L.”

• The control can be set at any position between “H” and“L”.

• The view window at the center of the pointer lets youobserve the powder flow (small white circle of powder)during operation. If no flow is seen, check for cloggingor add cleaning powder.

Page 12: Cavitron JET Combination System Ultrasonic Scaler … Manual for... · ENGLISH • 1 ENGLISH Cavitron™ JET Combination System Ultrasonic Scaler and Air Polishing Prophylaxis System

ENGLISH • 11

Section 8: Techniques for Use cont'd

The reusable components are wipe-disinfectable, using cleancloths and appropriate non-immersion type disinfectant. Wipeonce with disinfectant to remove bioburden, then use fresh clothand more disinfectant to clean surface. Dry with clean paper towelor air.

Step-by-Step Instructions:

1) Remove entire assembly from package.

2) Insert air polishing nozzle through JetShield™ cup and seatshoulder flush on nozzle. See Figure 2.

3) Insert connector on JetShield™ assembly into the flexibleejector tube.

4) Insert connector of ejector tube into operator saliva ejector.

1. Insert air polishing nozzle

2. Seat shoulder flush on nozzle

3. Incorrect positioning

�������

�������

8.6 Performing JET Air PolishingProcedures with JetShield™

NOTE: Refer to the Infection Control Card supplied with yourSystem for general procedures to be followed at the beginning ofeach day and between patients.

• Install JetShield™ on Cavitron Air Polishing Nozzle asindicated on instructions provided.

• Select the appropriate amount of powder using the dial onthe Cavitron™ JET or PROPHY-JET® 30 air polishingsystem.

• Verify that slurry exits from the cup when held outsidethe mouth; adjust saliva ejector as necessary.

• Divide the tooth visually into segments to polish (incisal,middle, and gingival).

• Apply cup to middle third with light pressure so cup flaresslightly.

• Pivot nozzle inside the cup to adapt to incisal, gingival,mesial and distal surfaces.

• Apply two seconds of spray for each segment of the tooth,releasing the Foot Control each time. If spray escapes,readjust cup to maintain flat contact with tooth surface.Adjust angle by pivoting nozzle inside the JetShield™cup.

• The suction from the JetShield™ can be used to removeexcess saliva from the patient's mouth.

• After completing each procedure, dispose of clearJetShield™ assembly according to Federal, State, and localregulations. Properly disinfect all other JetShield™accessories prior to reusing them on future patients.

5) Place ejector tube clip around ejector tube and handpiece cablesuch that cables drape together for patient and cliniciancomfort.

6) (Optional) Place handpiece clip along handpiece, close tohandpiece/cable connection, such that clip is holding theJetShield™ evacuation tube in place along handpiece.

7) Verify that slurry exits from the JetShield™ when air polishingunit is activated. Adjust saliva ejector as necessary.

8) Proceed with routine air polishing, applying cup to tooth socup flares slightly. Pivot nozzle inside cup, adapting to mesialand distal surfaces. Apply 2 seconds of spray for each segmentof tooth, releasing foot control each time. If spray escapes,readjust cup to maintain flat contact with tooth surface,adjusting angle by pivoting nozzle inside of handpiece.

After completion of each procedure, remove JetShield™ assemblyand dispose of JetShield™ according to applicable regulations.Wipe-disinfect all other components before next use.

Page 13: Cavitron JET Combination System Ultrasonic Scaler … Manual for... · ENGLISH • 1 ENGLISH Cavitron™ JET Combination System Ultrasonic Scaler and Air Polishing Prophylaxis System

ENGLISH • 12

Section 8: Techniques for Use cont'd

• The recommended normal procedure is to clean 2-3 teethwith the air polishing spray (foot control depressed to thesecond position) and then rinse the area with water only (footcontrol depressed to the first position) to inspect the work sitebefore proceeding to the next 2-3 teeth. If desired, the bleed air(foot control released) passing through the air polishing insert tipcan be used to dry the work site during inspection.

• Flushing the patient's tongue with water only (foot controldepressed to the first position) helps reduce the saline taste)

• Maintain a 3 to 4mm insert tip-to-tooth operating distance.

• The patient's lip should be held between the thumb and indexfinger of your free hand and pulled out and up, or down, toform a "cup". Do not retract the lips.

• Tilt the patient's head toward you to help prevent puddling inthe cupped lip and minimize aerosol dispersion.

• Use a saliva ejector or HVE.

• In the posterior regions, use the cheek to help contain aerosolspray.

8.7 Performing Air Polishing procedures without JetShield™

8.8 Proper Angulation of the Air Polishing Insert without JetShield™

Recommended angulation on theanterior teeth is 60° with the tip aimedat the middle third of the tooth surface.

Recommended angulationto occlusal surfaces is 90°.

Recommended angulation on the buccal andlingual surfaces of posterior teeth is 80° withthe tip aimed slightly distally.

• When air polishing the facial surfaces of the anteriors, center thespray on the middle third of the tooth and use a constantcircular motion. The edge of the spray will clean the teeth to thegingiva.

• Do not aim directly at the soft tissue.

• Avoid prolonged use on polished metal surfaces as a matte finishmay result.

• In the upper anterior region, use the upper lip and your hand asa shield to help contain the aerosol spray.

Page 14: Cavitron JET Combination System Ultrasonic Scaler … Manual for... · ENGLISH • 1 ENGLISH Cavitron™ JET Combination System Ultrasonic Scaler and Air Polishing Prophylaxis System

ENGLISH • 13

Section 9: System Care

9.1 Daily Maintenance

Start-Up Procedures at the beginning of the day:1. Open the manual shut-off valve on the dental water supply

system.

2. With the system OFF, unscrew the powder chamber cap.Verify the powder bowl is empty. Turn the Unit ON for 15seconds to eliminate residual powder or moisture in the lines.Turn the system OFF.

3. Shake the powder in the storage jar to create an even consis-tency of powder mixture.

4. Pour the powder into the chamber until it reaches the top ofthe center tube.

5. Secure the lid on the powder chamber.

6. Turn the system ON. Hold the Handpiece (without an insertinstalled) over a sink or drain, activate the Foot Control, andflush the water line at maximum water flow for at least 2minutes.

7. Place a sterilized Cavitron® Ultrasonic Insert or Cavitron™JET Insert Nozzle into the Handpiece and adjust the Powerand Lavage Flow as required. For the JET mode, the powderflow can be adjusted.

Between Patients:1. Remove Cavitron Ultrasonic Insert or Cavitron™ JET Insert

Nozzle (clean using the wire cleaning tool). Sterilize.

2. Set Water Control to highest setting. Activate the System andflush at least 30 seconds.

3. Turn the System OFF.

4. Clean and disinfect the surfaces of the cabinet, Power Cord,Handpiece Connector and cable assembly, Foot Control andcable assembly by applying an approved non-immersion typedisinfectant solution* carefully following the instructionsprovided by the disinfectant solution manufacturer. To cleansystem, generously spray disinfectant solution on a clean toweland wipe all surfaces. Discard used towel. To disinfect system,generously spray disinfectant on a clean towel and wipe allsurfaces. Allow disinfectant solution to air dry.

5. If using a closed water supply, check for adequate fluidvolumes for next patient’s scheduled treatment.

Shut-Down Procedures at the end of the day:1. Turn the Unit OFF.

2. Remove Cavitron® Ultrasonic Insert or Cavitron™ JET InsertNozzle (clean using the wire cleaning tool). Sterilize.

3. Unscrew the powder chamber cap.

4. Remove the powder chamber from the cabinet. Pour thepowder into the powder storage jar and secure the lid.

5. Hold the open end of the powder chamber away from you.Activate the System for 15 seconds to clear the powderchamber. A high volume evacuator can be used to remove anyresidual powder.

6. Secure the lid on the powder chamber.

7. Clean and disinfect the surfaces of the cabinet, Power Cord,Handpiece Connector and cable assembly, Foot Control andcable assembly by applying an approved non-immersion typedisinfectant solution* carefully following the instructions

9.2 Periodic Maintenance• The two repairable filters should be disassembled and

inspected every 90 days.

"O" RingDuckbillFilter

Repairable Filters:

provided by the disinfectant solution manufacturer. To cleansystem, generously spray disinfectant solution on a clean toweland wipe all surfaces. Discard used towel. To disinfect system,generously spray disinfectant on a clean towel and wipe allsurfaces. Allow disinfectant solution to air dry.

*NOTE: Water-based disinfection solutions are preferred. Somealcohol-based disinfectant solutions may be harmful and maydiscolor plastic materials.

If the System is connected to a DualSelect™ MedicamentDispensing System follow the recommended procedures listed inthe DualSelect™ manual.

If powder fluffing is observed when Foot Control is not in use,this would indicate an air leak. To correct, turn the Unit OFF,remove the Fill Cap, clean any residual powder from the O-ringseal and threads, replace the Fill Cap, tighten, and turn the Unitback ON.

Page 15: Cavitron JET Combination System Ultrasonic Scaler … Manual for... · ENGLISH • 1 ENGLISH Cavitron™ JET Combination System Ultrasonic Scaler and Air Polishing Prophylaxis System

ENGLISH • 14

Section 10: Troubleshooting

Although service and repair of the Cavitron™ JET CombinationSystem should be performed by DENTSPLY® personnel, thefollowing are some basic trouble shooting procedures that willhelp avoid unnecessary service calls. Generally, check all lines andconnections to and from the System, a loose plug or connectionwill often create problems. Check the settings on the System’sknobs.

Section 9: System Care cont'd

• Turn System OFF.

• Remove the Powder Chamber.

• Remove filter from holder and remove the tubing fromone end of the filter.

• Disassemble the filter as shown.

• Inspect the filter element. Replace if necessary.

• Reassemble the filter and reconnect the tubing and replacefilter in holder.

• Inspect second filter in a similar manner.

• Replace the Powder Chamber.

• Turn the System ON.

NOTE: Never operate the System without all filters in place.

10.1 Troubleshooting Guide

System will not operate:

(Power Indicator Light is not lighted)

1. Check that the Power switch is in the ON position, and thatdetachable Power Cord is fully seated in the receptacle on backof System.

2. Check that the System’s three-prong plug is fully seated in anappropriate AC receptacle, and that AC current is present.

(Power Indicator Light is lighted)

1. Check that the Foot Control Connector is fully seated in theFoot Control Receptacle on the back of the System.

System operates:

(No lavage flow at insert tip)1. Assure that Lavage control is properly adjusted.

2. Check that irrigant supply control valve/s (dental office watersupply) are open.

3. If connected to DualSelect™ Dispensing System, check thatfluid level in the selected bottle is sufficient. Make sure valvesare open when using external water source.

(JET Insert Nozzle blocks repeatedly)

1. Powder is moisture contaminated (lumpy). Discard powder.

2. Air filter is contaminated. Clean or replace filter.

(No bleed air)

1. Blocked JET nozzle. Clean JET Nozzle using supplied tool.

2. Blocked filter. Clean or replace filter.

(No or poor cleaning action)

1. Very low powder level or empty Powder chamber. Fill PowderChamber.

2. Blocked JET Nozzle. Clean JET Nozzle using supplied tool.

3. Fill Cap is loose. Tighten powder fill cap, and turn SystemON.

(Continuous powder agitation)

Fill cap not securely sealed. Shut System OFF. Remove theO-ring seal from the fill cap and clean residual powder from thecap. Be careful not to scratch or otherwise damage the plastic cap.Wipe off the O-ring and place it in the fill cap and turn SystemON.

10.2 Technical Support and Repairs

PointerView Window Fill Cap

Dump/PressureLine

Air-PowderFlow

Air Inlet

Air Supply Nozzle

Filter(depressurizing System)

Powder Bowl

For technical support and assistance call 1-800-347-7412Monday through Friday, 8:00 AM to 5:00 PM (Eastern Time).For other areas, contact your local DENTSPLY® representative.

Page 16: Cavitron JET Combination System Ultrasonic Scaler … Manual for... · ENGLISH • 1 ENGLISH Cavitron™ JET Combination System Ultrasonic Scaler and Air Polishing Prophylaxis System

ENGLISH • 15

Section 11: Specifications

���������� �����������������������������������

����������������� ���������������������

� ����� !"�!#��$�%���������&��' ���� ���(�)���*+����,���� �� ��-(�$������,���� �� (�-���$���&��./��� 0���� ��������1��+2�-��������

0�3�� ��������1�+24��������+���5� ����!6��������� )���5�� 7��!

+�8�5� 9:�#��!6�$�5� ";��!)��8$���������� #���!&���������������� "(��!,�.�����8� #7��!+����� $$��<���� "(��!���� $$��<���� "#��!

���������� �����������������������:�����������

����������������� ����������6�:��������=

� ����� !��!7��$�%������:��&��' ���� ���(�)���*+����,���� �� �9�-7�7>,����,���� �� 77#-("�>,�&��./��� 0���� ��������1��+2�-��������

0�3�� ��������1�+24��������+���5� �?7>�6��������� )���5�� ��?���

+�8�5� �#?9��6�$�5� �7?���)��8$���������� �?��&���������������� �?7�,�.�����8� �?��+����� $$��<���� �?7����� $$��<���� �?��

&����.���5 @�� A���$��������5������,���������������,B�

C$������� ����������� ��$���� ��� ����7�6��!����� �/�������) ��8���� :�D��9�D1���-���8������2

����$�����8����������8������

��$���� ��� ���9�6��!����� �/�������) ��8���� ��D��"�D1���-���8������2�����$5����,���� ��� �������(�5,�

TYPE B EQUIPMENT

FOOTSWITCH

Section 12: Classification

E �$��A$�������������������������5��>�������

E6������A$�������������������������5��>� �$�F

E6������A$�����������������5�5���A ���������A.�����C�8�����

E0�8��A�$�������������� � �

E6������A��A����A�$$�����������5�$��������A�A��������������5������3� ��.��5�����.��5�3����������� ��3�8���' �$�������� ������A�� �����5�$��������AA�������������5����� �� �3����!

SYSTEM ON/OFF

Page 17: Cavitron JET Combination System Ultrasonic Scaler … Manual for... · ENGLISH • 1 ENGLISH Cavitron™ JET Combination System Ultrasonic Scaler and Air Polishing Prophylaxis System

ENGLISH • 50

Worldwide Service CentersCentres de service après-vente mondiauxCentros de servicio mundiales

Printed in U.S.A. Form #80684 Rev. C 11/98

������������

�� �����������

����������������

������

Swiss RepresentativeDENTSPLY® DeTrey GmbH, KonstanzZweigniederlassung BaarOberdorfstrasse 11CH-6342 Baar

France

DENTSPLY® DeTrey17 Michael FARADAY78380 Montigny Le BretonneuxFrancePhone: (1) 30 14 77 77

Italia

DENTSPLY® DeTrey Italia s.r.l.Via A. Cavaglieri, 26I-00173 RomaItaliaPhone: (06) 723 3626

Australia

DENTSPLY® (Australia) Pty. Ltd.204-206 Gipps StreetAbbotsford, Victoria 3067AustraliaPhone: (3) 9417 1666

(3) 9417 1777

Canada

DENTSPLY® Canada161 Vinyl CourtWoodbridge, OntarioL4L 4A3 CanadaPhone: (905) 851-6060

U. S. A.

DENTSPLY® Preventive CareTechnical Service and Repair Department1301 Smile WayYork, PA 17404Phone: (800) 347-7412

Deutschland

DENTSPLY® DeTrey GmbHDe-Trey-Strasse 1D-78467 KonstanzGermanyPhone: 7531 583 0

United Kingdom

DENTSPLY® Ltd.Hamm Moor LaneAddlestone, WeybridgeSurrey KT15 2SEEnglandPhone: (0) 1932 853422

���� �!������

�� ���������"����"�����

�� ������#�����������$

%�&%�'�$����

���(���%)�&�

���*���+��,-�.���������"�

�� ������������/'�0

�1)2�3)4������+�/��'���


Recommended