    Practical Guidefor Planning and InstallingRIB-ROOF METAL ROOFING

  • 8/11/2019 zambelli planificare instalare

    2/88

    Wide range of materials,

    Colours and surfacesRIB-ROOF Profile sheets are available in a wide range of colours and materials.

    Aluminium smooth, double-sided coil coating, 0.7 0.8 0.9 1.0mmSheet steel, double-sided coil coating and galvanised, 0.63 0.75mm

    The complete range of accessories for RIB-ROOF includes formed parts and systemcomponents available in the same materials. Sliding clips are available inaluminium zinc, steel sheet and copper. RIB-ROOF metal roof systems aremanufactured in a wide range of materials. The following material and colourstyles (standard colours) and the above material strengths in boldface haveshorter delivery times:

    MATERIALSCOLOURS

    SURFACES

    Zambelli Practical Guide RIB-ROOF

    Other colour and surfaces on demand.

    Steel sheet 0.63mm, double-sidedcoil coating and galvanised

    RAL 3009 Oxide redRAL 7000 Squirrel greyRAL 8004 Copper brownRAL 8024 Beige brownRAL 9002 Grey whiteRAL 9006 White aluminium

    Aluminium 0.7mm smooth,double-sided coil coating

    RAL 7000 Squirrel greyRAL 8004 Copper brownRAL 8014 Sepia brownRAL 9006 White aluminiumRAL 9007 Grey aluminium

    Coating system: upper surface 25m poly-ester coil coating in RAL shades, Underside10m reverse protecting lacquer light

    Aluminium 1.0mm smooth,double-sided coil coating

    RAL 9006 White aluminium

    Aluminium 0.7 0.8 0.9 1.0mmmill finish stucco embossed

    Aluminium mill finish stucco embossed,double-sided protective coating 0.8 1.0mm

    Aluminium zinc 0.63 0.75mmwith steel core

    Titanium zinc 0.7 0.8 1.0mmdouble-sided protective coating or pre-weathered

    Copper 0.6mmTECU

  • 8/11/2019 zambelli planificare instalare

    3/88

    CONTEN

    3

    3

    3344

    5

    101013

    141415

    16161717

    18

    2122

    24

    26

    28

    30

    333436

    38

    40

    4042434446

    46

    4855565859616465

    7984

    1 General remarksPreface Metal materials

    1.1 Introduction1.1.1 Quality control1.1.2 Theory and practice1.1.3 Service

    1.2 Products Materials

    1.3 Constructional physics supporting structures

    1.3.1 Constructional physics1.3.2 Supporting structures

    1.4 Transport of materials storage1.4.1 Transport1.4.2 Storage

    1.5 Material handling1.5.1 Dividing and cutting1.5.2 Joining technique1.5.3 Bonding

    2 RIB-ROOF Speed 500

    2.1 Range of accessories2.2 Installation with sliding clip2.3 Installation on full surface

    support with clip guide

    2.4 Conical, cambered andconical cambered profile sheets2.5 Distance spans

    Clip distances

    3 RIB-ROOF 4653.1 Range of accessories3.2 Installation3.3 Cambered profile sheets3.4 Distance spans

    Clip distances

    4 Installation techniqueRoof covering in general

    4.1 Pro contra protective sheetwith open diffusion or com-pressed thermal insulation

    4.2 Laying technique4.3 Terraced gradient4.4 Transverse joint4.5 Longitudinal joint seal 5 Specific structures

    5.1 Eaves section5.2 Arris section5.3 Verge flashing section5.4 Lateral wall connection5.5 Eaves section5.6 Box type gutter5.7 Grooves5.8 Roof penetrations5.9 Snow fence, ice shield devices

    and mounting bracket forsolar module and harnesssecurity system

    Index

    Zambelli Practical Guide RIB-ROOF Page 1

  • 8/11/2019 zambelli planificare instalare

    4/88

  • 8/11/2019 zambelli planificare instalare

    5/88

    GENERAL REMAPREFAC

    INTRODUCTIO

    1.1

    .1.1

    1 General remarksPreface Metal materials

    The house is the focus of human experience. And yet, roofs came before wallssince roofs and roof coverings are as old as the hills. When human beings lived inprimitive caves they protected them with bark, leaves or straw. Long before thecoming of the Europeans, before the advent of western culture, human beings fromother societies built houses and equipped them with a roof. This protected fromthe whims of nature and hostile forces. The craftsmanship involved in coveringroofs has always been important. Metals are a historic building material that wasalready being used for technically and stylistically sophisticated buildings and forartisanship in the Bronze Age. The metal roof is rated highly in modern architecture,not least because of this.

    Introduction

    Quality control

    Zambelli Fertigungs GmbH & Co. KG has been making the RIB-ROOF metal roofsystem for over 30 years. The profile sheets are produced in one of the most modernfactories in Germany. RIB-ROOF Speed 500 and RIB-ROOF 465 in steel and aluminiumfinishes have a building inspection licence from DIBt the German Institute forConstructional Engineering in Berlin. Building inspection licencesRIB-ROOF Speed 500: No. Z-14.1-473 (steel), and No. Z-14.1-474 (aluminium);RIB-ROOF 465: No. Z-14.1-345 (steel), and No. Z-14.1-346 (aluminium).External monitoring is conducting by the testing laboratory at the University ofHannover. In order to ensure consistent quality of materials and production ZambelliFertigungs GmbH & Co. KG conducts inspections in addition to its own and externalmonitoring.RIB-ROOF metal roof systems are known for their optimal snug fit and first-classworkmanship. The advantages of a top quality product, its superior technical structureand finest expertise in finishing technique form the basis for an optimal result.

    Excerpt fromDas Dach und sein Handwerk

    Zambelli Practical Guide RIB-ROOF Page 3

  • 8/11/2019 zambelli planificare instalare

    6/88

    1.1.2 Theory and practice

    This Practical Guide is intended to assist you in the professional use of our productsand in ensuring that the buildings they cover retain their functionality and quality.

    This Guide complies with current trends in technology and has been compiled byus to the best of our knowledge and belief, but does not exonerate the workmanfrom making a critical appraisal in individual cases. This Guide may not form thebasis for any legal claims whatsoever. The provisions and guidelines in the building

    inspection licence must be observed.

    We provide intensive training courses for specialist companies to whom we passon our experience and our workmanship accumulated over many years.

    Theoretical and practical knowledge is imparted in special courses:Installation instructions by our trained personnel on siteTwo-day practical seminar focusing on installation techniqueOne-day theoretical seminar focusing on Constructional physics and roof construction

    Service

    This Practical Guide gives you standard solutions. If you require technical adviceon more advanced questions please phone +49 (0) 9931 8959-0 , we would bepleased to arrange a personal meeting of course.

    Please fax your enquiry to +49 (0) 9931 8959- 49and your e-mail [email protected].

    GENERAL REMARKPREFACE

    1.1.3

    Page 4 Zambelli Practical Guide RIB-ROOF

  • 8/11/2019 zambelli planificare instalare

    7/88

    Loading the mobileRoll-forming equipment

    1.2 Products Materials

    RIB-ROOF Benefit from a systemRIB-ROOF metal roof systems from Zambelli are an advancement in the traditionalhand-made standing seam system made as a result of technological progress inthe roll-forming technique. So-called sliding clips were developed from theconventional adhesives. RIB-ROOF is fitted without any perforations on the slidingclips designed exclusively for the system. The clips facilitate temperature inducedlongitudinal expansion of the profile sheets.

    The two product lines RIB-ROOF Speed 500 and RIB-ROOF 465 in the standard overallwidth 500mm and 465mm (for exact specifications see Chapter 2 RIB-ROOF Speed500 and Chapter 3 RIB-ROOF 465), a wide selection of materials, colours andsurfaces as well as a full range of accessories, RIB-ROOF has the right solution forevery need. It is self-supporting and accessible and can consequently be laid onpurlin or on a full area support the scope of application ranges from single shelled,rear ventilated roofs with air insulation to thermally insulated roof structures withoutair insulation.

    We will provide you with suitable proposals for solutions for roof refurbishmentswith business being conducted as usual in the building by using a roof span withRIB-ROOF on the existing roof surface. We have prepared individual design proposalsfor refurbishment of existing asbestos cement corrugated slabs or fibre cementslabs in particular. Please speak to us about it.

    RIB-ROOF can be laid from a pitch of only 1.5. The lock seam profiles are producedas required in the desired sheet lengths. All sizes of roof area can consequentlybe laid from the ridge to the eaves, normally without a transverse joint.

    Wide Variety of shapesRIB-ROOF profile sheets are available in conical, straight, curved or conicalcurved shapes. Sheets in extra long lengths from 33m upwards areprofiled and cambered on mobile roll-forming equipment directly onthe building site if required. In addition to the standard overall width,project-oriented dimensions are also produced on request.

    GENERAL REMAPRODUCTS MATER

    Zambelli Practical Guide RIB-ROOF Page 5

  • 8/11/2019 zambelli planificare instalare

    8/88

    Get moving now with RIB-ROOF!

    RIB-ROOF saves valuable installation time. The profile sheets are simply clicked intothe system-specific retaining clips. Pre-assembly and alignment of the clips is justas unnecessary with RIB-ROOF as is seaming or flanging with special flangingmachines. Since flanging is not necessary with RIB-ROOF, it can be installed at lowoutdoor temperatures. The profile sheets are available ex works with chamferedor bevelled edges on the side of the ridge or eaves.

    The full range of prefabricated elements facilitate flexible, efficient planning andfast, precise installation. All parts such as harness security system, snow fencesystems, skeleton steps and mounting bracket for solar module are installed onthe profile sheets without penetration.

    Wide range of materials, colours and surfaces

    RIB-ROOF profile sheets are available in a wide variety of materials and colours.You will find more information on the materials and colours in the summary onthe inside of the cover. All RIB-ROOF system components comply with class IIIcorrosion resistance in accordance with DIN 18807.

    GENERAL REMARKPRODUCTS MATERIAL

    Classes of corrosion resistance for roof system single shell

    Component side

    Upper surface

    Underside

    not insulated

    III 2

    II2 3

    upper surface thermally insulated, unventilated 1

    II 3

    a) over dry, predominantly enclosed areas Ib) over areas with high degree of humidity III

    underside thermally insulated

    III

    II3

    Page 6 Zambelli Practical Guide RIB-ROOF

  • 8/11/2019 zambelli planificare instalare

    9/88

    If adhesives are used they must be compatible with the coating.

    For ancillary buildings, e.g. tool sheds and storage sheds for the agricultural industryor covered parking spaces where the trapezoidal profiles are not only used forstabilisation, inclusion in class I corrosion resistance is admissible.

    For class II corrosion resistance and coil coated material customary painting 10mthick on the back is sufficient.

    and similar load distributing andor reinforcing sheet steel parts.

    Tables of corrosion resistancclasses in accordance with

    DIN 18807 Part 1

    GENERAL REMAPRODUCTS MATER

    Roof system double shell, ventilatedwith intervening thermal insulations

    Intermediate framework 4

    a) over dry, predominantlyenclosed areasII 3

    a) over areas with highdegree of humidityIII

    Bottom shell

    a) over dry, predominantly enclosed areas Ib) over areas with high degree of humidity IIIa) over dry, predominantly enclosed areas Ib) over areas with high degree of humidity III

    Component side

    Upper surface

    Underside

    Covering systems

    Component side

    Upper surface

    Underside

    Structural ribs filled with concrete

    I

    Structural ribs not filled with concrete

    a) over dry, predominantly enclosed areas I 3

    b) over areas with high degree of humidityIII

    Top shell

    III

    II 3

    a) over dry, predominantly enclosed areasI

    b) over areas with high degree of humidityIII

    1

    2

    3

    4

    Zambelli Practical Guide RIB-ROOF Page 7

  • 8/11/2019 zambelli planificare instalare

    10/88

    Minimum roof pitch in accordance with the general building inspectionlicence Germany:

    Compliance with the following minimum pitches is necessary when using profiledboards as water carrying outer shell for roofs:

    Minimum pitch of 1.5 (2.6%) for roofs without transverse joints.The required minimum pitch increases in roofs with transverse joints and or gaps(e.g. domelights) to 2.9 (5%).

    The required increase in the minimum pitch for gaps in roofs e.g. for domelights may be waived if the following requirements are met:

    Fully welded roof curbs are used.

    The roof curbs are welded with the top shell of the roof to attain maximum density.

    The certificate of suitability in accordance with the guidelines for welding supportingcomponents made of aluminium October 1986 version from the German Institute

    for Constructional Engineering has been obtained for welding profiled boards orwelding to the profiled boards with an extended area of application for componentsunder 1.5mm thick.

    The minimum pitch requirement is waived (at local level only) for the ridge areaif the roof elements in the area with pitches 2.9 (5%) are continuously (Note:for rounded roofs) arranged above the ridge.

    GENERAL REMARKPRODUCTS MATERIAL

    1.

    2.

    3.

    Page 8 Zambelli Practical Guide RIB-ROOF

  • 8/11/2019 zambelli planificare instalare

    11/88

    50 K 20m =24mmmm

    10m10K

    mm10m10K

    Temperature induced thermal expansion of the materials is ensured horizontallyby the profiled form and vertically by the potential for movement of the profilesheets on and in the sliding clips.

    Building- oriented production of the profile sheets from the ridge to the eaveswithout a transverse joint gives planners and roofers the greatest possible degreeof safety in the roofing trade.

    Table for the calculation oftemperature induced

    changes of length

    Material

    Aluminium 2.4Conrete 1.2

    Lead 2.9Bronze 1.8Stainless steel * 1.6Copper 1.7Brass 1.9PVC 8.0Titanium zinc 2.2Steel 1.2Brick masonry 0.5Zinc 2.9

    Tin 2.3*(Material Number 1.4301)

    Temperature induced change in length

    GENERAL REMAPRODUCTS MATER

    Coefficient of expansion between

    -20C and +80C in

    Example: temperature induced change of lengthfor aluminium material and a difference intemperature of 50K and a length of 20m.

    L= TL=2.4

    Zambelli Practical Guide RIB-ROOF Page 9

  • 8/11/2019 zambelli planificare instalare

    12/88

    Constructional physics Supporting structuresConstructional physics

    It is not intended to deal with the installation of supporting or substructures forthe RIB-ROOF profile sheets in detail, suffice it to say:the guidelines for the installation of metal roofs, external wall coverings andplumbing works by the ZVSHK (Central Association for Sanitation, Heating, AirConditioning) and the relevant DIN norms make a distinction between the so-called

    single shelled roof structures with an insulating layer (also called warm roof) orwithout an insulating layer and the double-shelled roof structures with rearventilation air circulation (also called cold roof).

    Rear ventilated metal roofs have an air space with vents for the air to flow inand out on the eaves and ridge as a rule in order to be able draw off thehumidity that condensates on the cold metal back and is present in the air space.

    A correct calculation depends on the structure and must be taken into considerationduring the planning and construction stages. Roof structures that do not adequatelyfacilitate natural air circulation must be equipped with mechanical ventilation. It

    is well known that a number of factors may have an adverse effect on howventilation functions in a double-shelled roof structure. A single-shelled structurewith a vapour barrier (Sd value 100 m) without any levels of ventilation isconsequently recommended for buildings that are in the planning stage for economicreasons.

    Insulated, unventilated roof structures require the vapour barrier to be attachedto the adjacent and rising components as well as roof penetrations so that it iswindproof and vapour proof.Distance profiles moulded from sheet steel act as a thermal bridge and reduce

    insulation of the building. There is an increased risk of formation of water producedon thawing and resultant damage to the primary structure through corrosion. Adistance structure made of squared timber is thus recommended.

    The results of calculations made by the Forschungsinstitut fr Wrmeschutz e.V.,clearly show the adverse effect of metallic distance structures. The With regard tothe U value calculation (formerly k value) of the entire roof structure, the effectof the retaining structure must be observed in order to obtain the thermal insulationlicence in accordance with the energy saving regulations.

    1.31.3.1

    DIN 4102DIN 4108DIN 4109

    GENERAL REMARKCONSTRUCTIONAL PHYSSUPPORTING STRUCTUR

    Page 10 Zambelli Practical Guide RIB-ROOF

    An important requirement forfunction, quality and efficiencyof a building is compliance withthe basic rules of constructionalphysics. These are specified inthe German industrial norms(DIN) for example:

    4102 Behaviour in fire ofbuilding materials and com-ponents,4108 Thermal insulationclimate induced damp proofingin building construction and4109 Sound insulation inbuilding construction

    and must be complied with inindividual cases.

  • 8/11/2019 zambelli planificare instalare

    13/88

    In certain circumstances the guidelines of the ZVSHK (Central Association forSanitation, Heating, and Air Conditioning) recommend the installation of thermalinsulation with a protective sheet with open vapour diffusion on the thermalinsulation to protect it from humidity and secondary water produced on thawingwhich may form temporarily on the back of the metal during unfavourable weatherconditions. The need for precise fixing to the adjacent and rising components isunderlined.

    There is no need to use these open diffusion protective sheets when the underlyingmineral thermal insulation is compressed by approx. 20mm.

    There is additional information on this subject in Chapter 4.5 for against opendiffusion protective sheets or compressed thermal insulation.

    The components made of various metals depicted in the table possible assemblyof metals must not come into direct contact when these metals show varyingdegrees of tension potential and the metal with the higher tension potential lies

    above the flow direction of the rainwater which acts as an electrolyte.

    When the RIB-ROOF profile sheets areassembled with other building materialsor components the following must beobserved to prevent contact corrosion.

    Metals with a coating of paint, copperand stainless steel do not require any

    special measures.

    Aluminium zinc and bare aluminiummust be protected from stress causedby alkalis from mortar or concrete byinstalling dividing layers and byaggressive wood preservative or animpregnating agent.

    GENERAL REMACONSTRUCTIONAL PHSUPPORTING STRUCT

    Metallic compoundsPossible assembly of metals

    Galvanised steel Alum. Zinc Copper Stainl. steel Lead

    Galvanised steel + + + - + +Aluminium + + + - + +

    Zinc + + + - + +Copper - - - + + +

    Stainless steel + + + + + +Lead + + + + + +

    + Assembly- no assembly

    Zambelli Practical Guide RIB-ROOF Page 11

    Table of possible assembly ofmetals with positive andnegative metallic compounds

  • 8/11/2019 zambelli planificare instalare

    14/88

    The use of titanium zinc requires special attention.

    Contact of titanium zinc with other building materials is dealt with at length in thespecialised literature (titanium zinc in civil engineering, published by Zinkberatung,Dsseldorf). Based on our many years of experience we would like to make acomment which is largely supported by the titanium manufactures. The effects ofthe atmosphere cause titanium zinc to form a natural protective layer on its surface.This layer is known as a patina. This is not possible in the required degree on theunderside of the roof with full surface support of the titanium zinc sheets sincethere is not sufficient air movement in this area. The secondary water formed bythawing on the back of the metal and the resultant permanent humidity lead tothe familiar titanium zinc damage.

    For construction with titanium zinc and pitches 15 it is thus recommended thatthe underside of the profile sheets be protected with a lacquer coating or distancestructures be installed at the adjacent constructional level.

    GENERAL REMARKCONSTRUCTIONAL PHYSSUPPORTING STRUCTUR

    RIB-ROOF (Titanium zinc)

    Shuttering (not pounded)

    Rear ventilation level

    Open vapour diffusion protective sheet

    Lateral and counter lathingwith intervening thermal insulation

    Vapour barrier

    Trapezoidal sheet metalPage 12 Zambelli Practical Guide RIB-ROOF

    Ai r

    Model roof construction withrear ventilated level fortitanium zinc profile sheets

  • 8/11/2019 zambelli planificare instalare

    15/88

    GENERAL REMACONSTRUCTIONAL PHSUPPORTING STRUCT

    Zambelli Practical Guide RIB-ROOF Page 13

    Supporting structures

    Steel trapezoidal profiles are one of the most common supporting structures. Thisdesign forms the basis for the specifications and photographs below.

    Installation of these and alternative substructures and possible fastening elementsare summarised in the following table.

    Table of possibleRIB-ROOF substructures a

    the required fastening material.

    1.3.2

    RIB-ROOF SubstructuresSubstructure Fastening material

    Wood lathing wood purlin Wood screw with full thread6 x 40mm

    Roof boards Wood screw with full threadt = at least 24.0mm 6 x 30mm or 5 x 25mmSteel purlin Self-drilling screwst 4.0mm 5.5 x 25mm or

    Aluminium blind rivet with head 15.0 mm

    or 4.8 x 17 mm; pre-drilling necessarySteel purlin Aluminium blind rivet with head 15.0mmt 4.0mm or 4.8 x 17mm; pre-drilling necessaryTrapezoidal profile Self-drilling screws, 5.5 x 25mmWood lathing Self-drilling screws Torx T25on trapezoidal profile SFS SD2 KL-(S)-S11-6*L

    Ejot JT3 JT2-ST-2-6,0*LPorous concrete SFS-IGR, Ejot SDP

    (Pay attention to summary values)Reinforced concrete Dowel system Ejot SDF 8.0mm

    Fastening materials for other substructures.

  • 8/11/2019 zambelli planificare instalare

    16/88

    On site mobile roll-formingequipment facilitates the production

    of extra long lengths directly on thebuilding site.

    1.41.4.1

    GENERAL REMARKSTRANSPORT AND

    STORAGE OF MATERIAL

    Transport of material StorageTransport Unloading

    The profile sheets are transported by lorrywithout a crane. Access to the destinationmust be ensured. For extra long lengths(from approx. 33m upwards) productionis possible at the building site with mobileroll-forming equipment.

    The material must be checked forcompleteness and damage immediatelyupon delivery.The consignments are marked with:delivering works profile designation licence number.

    Complaints must be entered on the dispatch documents and our factory notifiedwithout delay.

    The consignments of profile sheets (weight of consignment max. 1.5 t) must beunloaded with suitable lifting gear (crane or high-lift truck). Please ensure that thecrane or high-lift truck is made available in time once you have arranged thedelivery date with our works.

    Delivery to the building site is generally made without providing a crane orhigh-lift truck.

    A crane traverse (suspension

    bracket) including fixed crane hookwithout harness, deadweight980kg, plus payload max. 1500kgwill be supplied if required.

    Unloading using crane and crane traverse(suspension bracket). Harnesses minimumwidth of 10cm protect the profile sheets frommechanical stress and damage.

    Page 14 Zambelli Practical Guide RIB-ROOF

  • 8/11/2019 zambelli planificare instalare

    17/88

    When cranes are deployed unloading must be done with harnesses. The edges ofthe profile sheets must be protected from mechanical damage. RIB-ROOF 465 withsheet lengths of approx. 12m for aluminium, copper and titanium zinc and approx.18m for steel require the deployment of traverses. Projections of more than 4.50mfor aluminium and steel, or more than 2.0m for copper and titanium zinc must beavoided. If the sheet lengths for RIB-ROOF Speed 500 are more than approx. 10m,they should be unloaded with a traverse.

    Putting down and storage on the roof requires taking the load-bearing capacity ofthe substructure into consideration. The profile sheets must be secured to preventthem slipping and sliding down.

    Storage

    If the profile sheets are not going to be installed immediately, they must beadequately protected from weather factors. They must be stored in the directionof the profile to allow rainwater and secondary water produced by thawing torun off. If they are covered with tarpaulins, the latter must be windproof andbe adequately ventilated. Liability is not accepted for damage caused byimproper storage.

    1.4.2

    GENERAL REMATRANSPORT AN

    STORAGE OF MATE

    Zambelli Practical Guide RIB-ROOF Page 15

    Projection max. 4.50m or 2.00mfor copper and Titanium zinc

    >10m

    >6m

  • 8/11/2019 zambelli planificare instalare

    18/88

    1.51.5.1

    Material handlingDividing and cutting

    Dividing and cutting the RIB-ROOF elements is done with suitable nibbling tools,sheet metal shears, compass saw or hand circular saw with a carbide cutting blade.The nibbling attachments for RIB-ROOF may be purchased from our range ofaccessories. The use of cutting-off wheels must be avoided; the resultant showerof sparks damages the surface of the material and may lead to corrosion damage.

    Corrosion resistant materials (sheet steelwith aluminium zinc alloy or coil coatedand coated with paint) do not requiresubsequent treatment of the cut edges.

    Drilling chips and sliced particles must beremoved from the surface immediately

    as they can also cause damage to thematerial.

    The different properties of the materialsmust be taken into consideration whenshaping flat sheets from RIB-ROOF basicmaterial. The table on the left shows theminimum bending radii of the metals.

    Markings must not be made with sharp objects; we recommend using soft pencils.Table of minimum bending radiifor different metals

    GENERAL REMARKMATERIAL HANDLIN

    Page 16 Zambelli Practical Guide RIB-ROOF

    Bending radii for edge parts made out of RIB-ROOF basic material

    The different properties of the materials must be taken into considerationWhen shaping flat sheets (here bending on an edge bench) from RIB-ROOF basic material .The table shows the minimum bending radii witha minimum bending radius of 3.00 x thickness of material t in mmwith a processing temperature of 20 Celsius applying to the materialvariations for aluminium.

    Material smallest possible bending radius

    Aluminium, t =0.70mm 2.10 mmAluminium, t =0.80mm 2.40 mmAluminium, t =0.90mm 2.70 mmAluminium, t =1.00mm 3.00 mmSteel 2.50mmTitanium zinc 1.75mmCopper 1.75mm

  • 8/11/2019 zambelli planificare instalare

    19/88

    Maintenance tipThe agents used to clean the metal surfaces should not be aggressive butbiodegradable and environmentally friendly.Rinsing in cold water is generally necessary. Correction of damage to the paintworkmust be done with particular care. Paints for our standard range of shades areavailable on request but may differ slightly in hue. The manufacturer must beconsulted before damage to the zinc layers is treated. Minimal differences in the

    painted and natural surfaces may result from the use of different batches, but arenot deemed to be a defect.

    Joining technique welding solderingThe different properties of the materials must be taken into consideration when

    joining metals (also see Chapter 1.3.1).The paint from coated aluminium strips must be removed before they are weldedor soldered. Once the work is completed the bare surface must be repainted with

    the appropriate paint system.The technique for the joining methods is described in detail in the instructions foruse supplied by the manufacturers of the materials, e.g. Alcan aluminium, Hoesch sheet steel, VM zinc titanium zinc and KM-Europametall copper.

    BondingAs the leaflet Bonding in plumbing technique by the ZVSHK (Central AssociationSanitation Heating Air Conditioning) in 53757 St. Augustin states, bonding of metalmaterials is also a possible alternative in plumbing technique. Single-component

    polyurethane bonding agents are normally used in plumbing technique.

    1.5.2

    1.5.3

    GENERAL REMAMATERIAL HANDL

    Zambelli Practical Guide RIB-ROOF Page 17

  • 8/11/2019 zambelli planificare instalare

    20/88

    RIB-ROOF Speed 500

    RIB-ROOF SPEED 500

    2

    Page 18 Zambelli Practical Guide RIB-ROOF

    Clip borders: finish profiled and flat(construction length 3m)

    RIB-ROOF Speed 500

    Standard clip system Speed 500 modelStainless steel t=1.20mm

    Aluminium zinc t=1.30mmCopper t=1.30mm

    Standard clip and RIB-ROOF profile Speed 500 on wood lathing standard construction width 500mm, special construction widths for example 333mm or 400mm.

  • 8/11/2019 zambelli planificare instalare

    21/88

    RIB-ROOF SPEED

    RIB-ROOF Speed 500 Benefit from a system

    Building inspection licenceNo. Z-14.1473 (steel), No. Z-14.1474 (aluminium)

    may be used from 1.5 pitch upwards

    Installation on sliding clips or clip border without penetration

    accessible and self-supporting consequently suitable for all standard fields ofapplication on purlins or full surface support from the single-shelled rearventilated cold roof to the thermally insulated unventilated roof structure

    ultimate in easy, quick installation also during low outside temperatures no pre-assembly required for the sliding clips and no mechanised beading of theprofile sheets

    no transverse joint since there is virtually no limit to the length Profile sheets up to 33m length by lorry, longer lengths building site profiling

    standard construction width 500mmother overall widths on request

    conical and conical curved profile sheets

    curved profile sheets from a radius of 2mon smaller radii on demand

    full range of accessories, wide range of material and colours

    Profile sheets available from the works with ridge side bending of the bottomchord or eaves side beading.

    Zambelli Practical Guide RIB-ROOF Page 19

  • 8/11/2019 zambelli planificare instalare

    22/88

    RIB-ROOF SPEED 500

    As an advancement on RIB-ROOF 465 and RIB-ROOF 500, Speed 500 combines thebenefits of both metal roof systems: large distances between clips, self-supporting,accessible profiled sheets, ultimate in easy, quick installation

    The lock seam profiles are produced to meet individual structural requirements inthe desired sheet lengths so that roof areas of all sizes from 1.5 pitch upwardsmay be laid without a transverse joint. Speed 500 is installed without penetrationand with its own system sliding clips. It may be laid either on purlins or on full-surface supports such as safe thermal insulation or shuttering for all standard typesof roof construction.

    RIB-ROOF Speed 500 saves valuable installation time the profile sheets are simplypushed into the clips and swivelled. On a full-surface support 6 clips are laidsimultaneously with a clip at exactly the same distance apart. Moreover, there is noneed to perform time consuming beading of the profile sheets at the building site.

    Wide variety of shapesRIB-ROOF Speed 500 is available in straight, conical, curved orconical curved profilesheets (see Chapter 2.4). Conical profile sheets may be finished with a minimumoverall width of 230mm and a maximum standard overall width of 500mm. Inaddition to the standard overall width of 500mm, other overall widths, e.g.333mm, 400mm or up to 600mm are produced on request (see Chapter 2.4.1).

    Profile sheet lengths over 33m are profiled on mobile roll-forming equipmentdirectly at the building site. Curved profile sheets RIB-ROOF Speed 500: Curved(arched) profiled sheets are finished by forced arching at the building site ormechanical arching (by the works or at the building site) available from June 2005onwards. Installation and radii see Chapter 2.4.2.

    As a complete metal roof system RIB-ROOF Speed 500 offers a suitable solutionfor every need. The complete range of accessories with useful articles that makethe work easier and save valuable time is shown on the next page.

    Page 20 Zambelli Practical Guide RIB-ROOF

  • 8/11/2019 zambelli planificare instalare

    23/88

    RIB-ROOF SPEED RANGE OF ACCESSO

    2.1 Range of accessories

    Zambelli Practical Guide RIB-ROOF Page 21

    Profile sheet standard construction width 500mm Profile sheet special construction width 400mm Standard clip

    Profile sheet special overall width 333mm Clip borderTurned clip

    Conical profile sheet

    Harness security systemToolsSpecial edge parts

    Tread holder

    Coil

    Mounted bracket forsolar module

    lightning conductorIce stopper

    Profile filler onthe upper surface

    Profile filler forthe undersideEaves blind

    Ridge cap

    Snow fence pipe Pipe connector

    Verge flashing cap

    Curb

    Clamping plate

    Closure

    Verge flashinginsert profile Gutter inlet sheetVentilation ridge cap

    Eaves angle

    Fastening angle

    Ventilation closure

    Lock plate

    Clip bar

    Curved profile sheet

  • 8/11/2019 zambelli planificare instalare

    24/88

    Installation with sliding clips

    Place the first row of clipsAlign the clips along the side of the verge flashing and fasten them with theapproved rivets or screws to the substructure. Additional pre-assembly is notrequired. The distances between the clips depend on building-specific data andwind loads (see Chapter 2.4). Please note: only use countersunk heads for clipfastening with screws.

    Insert first profile sheet

    Push the small rib of the ridge profile sheet into the clips. Then swivel the profileshee t down onto the substructure. Each profile sheet will subsequently be securedwith an anchor point to prevent it from sliding down. To bent the bottom chordupwards at the ridge and to bent it downwards at the eaves a bending tool isused. This can be done either in the factory or on-site.

    For pitches

  • 8/11/2019 zambelli planificare instalare

    25/88

    Place the next row of clipsThe position of the next row of clips depends on the overall width of the profilesheets. This does away with the need for pre-assembly and alignment of theclips with a plumb line. Insert the sliding clips with a single hand movement intothe large rib. Then swivel, click into place in the rib and fasten to the substructure.

    Insert next profile sheetPush the next profile sheet with its small rib under the clip and the large rib ofthe first profile sheet. Then swivel downwards and click into the clip. Timeconsuming beading of the profile sheets is not required. Speed 500 is reinforcedin the eaves area by joining the bottom flanges to an eaves angle. (Chapter 5.5)

    RIB-ROOF SPEED INSTALLATION W

    SLIDING CLI

    Zambelli Practical Guide RIB-ROOF Page 23

    3.

    4.

    anchor point at the side (as analternative it is possible to makethe anchor point on top togetherwith the fixing of the closure)

    For the curved profile sheets of RIB-ROOF Speed 500with radii under 100 m turned clips have to be used(direction of installing: right to left).Measurements of the fastening screws(no flat head screws)screw head- max.: 10.50 mm

    screw head-height: 5.50 mm

  • 8/11/2019 zambelli planificare instalare

    26/88

    Installation on full-surface support with clip border

    RIB-ROOF Speed 500 may alternatively be installed on full-surface supports. Avariation in addition to the roof boarding is the high compressive strength mineralwool with high density top layer which improves the resistance to site work(application type DAA-dm according to DIN V 4108-10: thermal insulation).

    Installation of the profile sheet may either be done on distance profiles whichcorrespond to the thickness of the thermal insulation or on the clip border structureprofiled or flat, which is fastened directly onto the support structure.It is vital to avoid gaps when laying the insulating boards. This finish is alsotransferable to RIB-ROOF 465 if so-called pressure distribution profiles are used.

    RIB-ROOF SPEED 500INSTALLATION WITH

    CLIP BORDER

    2.3

    Page 24 Zambelli Practical Guide RIB-ROOF

    Installation with clip border onhigh compressive mineral wool

    The thermal insulationmust be milled out ifprofiled clip bordersare used.

  • 8/11/2019 zambelli planificare instalare

    27/88

    Areas of application of the clip border finish flat or profiled RIB-ROOF Speed 500:

    You always use the flat clip border on full surface supports, e.g. shuttering ornon-slip thermal insulation when the fastening screws can be placed in theerected clip and then in the subsequent webbed area of the profiled sheet andthe screw heads thus disappear into the hollow space of the web.

    You use the profiled clip border on full surface supports such as non-slip thermalinsulation when the clip border must (also) be fastened between the clips andthe screw heads must disappear into the lateral cavity of the clip border. Foroptimal laying, the safe thermal insulation is milled out at the building site to

    the exact fit of the geometry of the profiled clip border with a mobile millingdevice. Should you place an order, the milling device which resembles a lawmower will be supplied by us. If the profiled clip borders are needed on a lengthof more than 30 m, the clip borders have to be installed not one behind theother but moved a little bit or interrupted by a turned clip so that the expansionis guaranteed.

    Possible subsequent opening of the RIB-ROOF Speed 500 profile sheets(e.g. for subsequent installation of roof penetrations) is done with the wedge madeof toughened plastic.

    RIB-ROOF SPEED INSTALLATION W

    CLIP BORDE

    Zambelli Practical Guide RIB-ROOF Page 25

    Clip border, profiledConstruction length 3m

    (borehole on clip 7mm,otherwise 6mm)

    Wedge for opening profile sheeRIB-ROOF Speed 50

    clip border, flatconstruction length 3m

    (borehole 7mm)

  • 8/11/2019 zambelli planificare instalare

    28/88

    Conical, curved andconical curved profile sheetsConical profile sheets

    RIB-ROOF Speed 500 is also available in conical, curved and conical curved profilesheets. Conical profiled sheets may be finished with a minimum overall width of230mm and a maximum standard-overall width of 500mm. In addition to thestandard overall width of 500mm, other overall widths, e.g. 333mm, 400mm ormaximum 600mm will be produced on request.

    RIB-ROOF SPEED 500CONICAL, CURVED

    PROFILE SHEETS

    2.4

    2.4.1

    Page 26 Zambelli Practical Guide RIB-ROOF

  • 8/11/2019 zambelli planificare instalare

    29/88

    Curved and conical curved profile sheets

    The following minimum bending radii must be taken into consideration for me-chanical cambering; they depend on the type of material and thickness [t]:

    RIB-ROOF SPEED CONICAL, CURV

    PROFILE SHEE

    Zambelli Practical Guide RIB-ROOF Page 27

    2.4.2

    For smaller radii, conical curved and concave profile sheets please ask Zambelli.

    For radii > 100 m the profile sheets are curved without a machine and fixed witha sliding clip. For radii under 100 m the turned clip has to be used (direction ofinstalling: right to left). As during the forced curving on-site the profile sheets haveto be pushed onto the radius, dents can sometimes not be avoided. The curvingby machine is the optical better solution.

    Table of minimum bending radiifor different metals

    Minimum bending radiiconvexe Profile sheets RIB-ROOF Speed 500

    Material Material thickness [t] radius[mm] [m]

    Steel 0.63 4.00Aluminium 1.00 2.00Aluminium 0.80 oder 0.90 3.00Aluminium 0.70 4.00Titanium zinc 1.00 on demandCopper 0.60 on demand

    For radii under 100m theturned clip has to be used(direction of installing:right to left).Measurements of thefastening screws(no flat head screws)screw head- max.: 10.50 mmscrew head-height: 5.50 mm

  • 8/11/2019 zambelli planificare instalare

    30/88

    Spans clip distancesfor enclosed hall-type buildings

    Height of building h < 8.00m

    RIB-ROOF SPEED 500SPANS

    CLIP DISTANCES

    Sheet steel 0.63 4.63 (3.67) 1.54 (1.22) 0.87 (0.69) 1.70 (1.70)0.75 5.77 (4.57) 1.92 (1.52) 1.08 (0.86) 2.50 (2.50)0.88 5.77 (4.57) 1.92 (1.52) 1.08 (0.86) 3.00 (3.00)

    Aluminium 0.70 3.43 (2.70) 1.14 (0.90) 0.64 (0.51) 1.20 (1.20)0.80 4.47 (3.53) 1.49 (1.18) 0.84 (0.66) 1.50 (1.50)0.90 5.07 (4.00) 1.69 (1.33) 0.95 (0.75) 1.70 (1.70)1.00 5.67 (4.50) 1.89 (1.50) 1.06 (0.84) 1.90 (1.90)

    Sheet steel 0.63 2.86 (2.29) 0.97 (0.76) 0.54 (0.43) 1.70 (1.70)

    0.75 3.60 (2.85) 1.20 (0.95) 0.68 (0.54) 2.50 (2.50)0.88 3.60 (2.85) 1.20 (0.95) 0.68 (0.54) 3.00 (3.00)

    Aluminium 0.70 2.15 (1.69) 0.72 (0.56) 0.40 (0.32) 1.20 (1.20)0.80 2.79 (2.21) 0.93 (0.74) 0.52 (0.41) 1.50 (1.50)0.90 3.17 (2.50) 1.06 (0.83) 0.59 (0.47) 1.70 (1.70)1.00 3.54 (2.81) 1.18 (0.94) 0.66 (0.53) 1.90 (1.90)

    Page 28 Zambelli Practical Guide RIB-ROOF

    2.5

    for RIB-ROOF profile sheets Speed 500, clip from sheet steel with aluminium zinc(clip from stainless steel)

    for RIB-ROOF profile sheets Speed 500, clip from sheet steel with aluminium zinc(clip from stainless steel)

    Material Material thickness Clip distance Clip distance Clip distance max. span ofaccessibility deter-

    (mm) Normal area (m) Edge area (m) Corner area (m) mined by installation

    wind loads according to DIN 1055 part 4: w=0.48kN m2 w=1.44kN m2 w=2.56kN m2

    Material Material thickness Clip distance Clip distance Clip distance max. span ofaccessibility deter-

    (mm) Normal area (m) Edge area (m) Corner area (m) mined by installation

    wind loads according to DIN 1055 part 4: w=0.30kN m2 w=0.90kN m2 w=1.60kN m2

    Height of building h > 8.00m < 20.00m

  • 8/11/2019 zambelli planificare instalare

    31/88

    We would be pleased to assist you in calculating the clip distances (or spans) foran individual building. The summary values of the fastening agents you choosefor the respective substructure must be checked. Please contact us.

    The maximum accessibility span for titanium zinc is 0.60m for multiple-span andsingle-span girders. A full surface support or corresponding substructures arerequired. The maximum accessibility span for copper is 1.20m.

    The width of the edge and corner area is the respective width of the buildinga 8 in accordance with DIN 1055 Part 4.

    The edge and corner are consequently at least 1m and may be limited to 2m widthfor residential and office buildings and enclosed hall-type buildings with a 30 m.

    The wind loads were taken into consideration according to DIN 1055 part 4.

    If the turned clip is used the values of the clip distances has to be reduced for steelby 15% and for aluminium by 10%.

    Table showing spansor clip distances

    Height of building h > 20.00m < 100.00m

    RIB-ROOF SPEED SPANS

    CLIP DISTANC

    Sheet steel 0.63 2.11 (1.67) 0.70 (0.56) 0.40 (0.31) 1.70 (1.70)0.75 2.62 (2.08) 0.87 (0.69) 0.49 (0.39) 2.50 (2.50)0.88 2.62 (2.08) 0.87 (0.69) 0.49 (0.39) 3.00 (3.00)

    Aluminium 0.70 1.56 (1.22) 0.52 (0.41) 0.29 (0.23) 1.20 (1.20)0.80 2.03 (1.61) 0.68 (0.54) 0.38 (0.30) 1.50 (1.50)0.90 2.30 (1.82) 0.77 (0.61) 0.43 (0.34) 1.70 (1.70)1.00 2.58 (2.05) 0.86 (0.68) 0.48 (0.38) 1.90 (1.90)

    Zambelli Practical Guide RIB-ROOF Page 29

    for RIB-ROOF profile sheets Speed 500, clip from sheet steel with aluminium zinc(clip from stainless steel)

    Material Material thickness Clip distance Clip distance Clip distance max. span ofaccessibility deter-

    (mm) Normal area (m) Edge area (m) Corner area (m) mined by installation

    wind loads according to DIN 1055 part 4: w=0.66kN m2 w=1.98kN m2 w=3.52kN m2

    The table is valid for bothstandard clips and clip

    borders.

  • 8/11/2019 zambelli planificare instalare

    32/88

    RIB-ROOF 4653

    Page 30 Zambelli Practical Guide RIB-ROOF

    465

    48

    RIB-ROOF 465

    Standard clip andRIB-ROOF-profile 465

    on wood lathing

    Standard clip system 465:

    Aluzinc t=1.30mmStainless steel t=1.20mmCopper t=1.30mm

    Start clip 465

  • 8/11/2019 zambelli planificare instalare

    33/88

    RIB-ROOF 465 Benefit from a system

    Building inspection licenceNo. Z-14.1345 (steel), No. Z-14.1346 (aluminium)

    may be used from 1.5 pitch upwards

    Installation without penetration on sliding clips

    self-supporting and accessible thus suitable for all normal areas of applicationon purlins or full-surface supports from a single-shelled, rear ventilated cold roofto a thermally insulated, unventilated roof structure

    ultimate in easy, quick installation also during low outdoor temperatures since no pre-assembly of the sliding clips and no mechanical beading of the profilesheets is required

    no transverse joint since virtually no limit to length Profile sheets up to33m length by lorry, longer lengths profiled at the building site

    Conical profile sheets (on request)

    Curved profile sheets from 6m radius upwards (small radii on request),alternative rounding by bending

    full range of accessories, extensive range of material and colours

    Profile sheets with ridge side beding of the bottom chord or eaves sidebeading available from the works

    RIB-ROOF 46

    Zambelli Practical Guide RIB-ROOF Page 31

  • 8/11/2019 zambelli planificare instalare

    34/88

    RIB-ROOF 465

    RIB-ROOF 465, is the proven metal roof system for over 30 years with large clipdistances, self-supporting and accessible profile sheets, quick, easy installation.

    The customised lock seam profiles are produced in the desired sheet lengths sothat all sizes of roof areas from 1.5 pitch upwards may be laid without a transverse

    joint.

    RIB-ROOF 465 is installed without penetrations with its own system sliding clips.For all standard types of roof construction it may either be laid on purlins or fullsurface supports with safe thermal installation or shuttering.

    RIB-ROOF 465 saves valuable installation time the clips are simply swivelled intothe profile sheets without any pre-assembly. Moreover, no time consuming beadingof the profile sheets at the building site is necessary.

    Wide variety of shapes

    RIB-ROOF 465 is available in straight or curved profile sheets (seeChapter 3.3): Profile sheet lengths over 33m are profiled on mobile roll-formingequipment directly on the building site.

    If the inside micrometer for narrow radii and long profiled sheets is so large thattransport of extra longer widths becomes impossible, the profile sheets must becambered at the building site.

    As a complete metal roof system, RIB-ROOF 465 offers a suitable solution for everyrequirement. The full range of accessories with useful articles that make the work

    easier and save valuable time is shown on the next page.

    Page 32 Zambelli Practical Guide RIB-ROOF

  • 8/11/2019 zambelli planificare instalare

    35/88

    RIB-ROOF 46RANGE OF ACCESSO

    Range of accessories3.1

    Zambelli Practical Guide RIB-ROOF Page 33

    Profile sheet Standard clipCurved profile sheet Start clip

    End clip Closure

    Lock plate

    Anchor point clip Diagonal clip

    Pipe connectorClamping plate

    Eaves angle

    Snow fence pipe

    Verge flashinginsert profile Verge flashing cover

    Profile filler upper side

    Ridge cap

    Gutter inlet sheet

    Ventilation ridge cap

    Ventilation closureEaves blind Profile filler for underside

    Coil Special edge parts Curb

    Ice stopper

    Fastening angle Tread holder

    Tools Harness security system

    Mounted bracket forsolar module

    lightning conductor

  • 8/11/2019 zambelli planificare instalare

    36/88

    Installation

    Place the first row of clips

    Align the clips (start or standard clips) along the side of the verge flashing andfasten them with the approved connecting elements (Chapter 1.3.2). Additionalpre-assembly of the sliding clips is not required. The distances between the slidingclips depend on building-specific data (spans, clip distances for enclosed hall-typebuildings see Chapter 3.4). Allowance must generally be made for increased wind

    loads in the edge and corner areas.

    Insert first profile sheet

    The first profile sheet with its large rib is swivelled into the overlapping start clipand is clamped into the medium-sized rib on the clip. Alternatively, using thestandard clip press the large rib with the overlapping area together and clamp theprofile sheet with the large and medium-sized rib onto the clip from above (clicksaudibly into place). Secure the profile sheet with clamps, which overlap the external

    rib, on the substructure (not necessary is the start clip is used).

    Place the next row of clips

    The position of the next row of clips depends on the overall width of the elements.To ensure that the profile sheets are laid parallel to and flush with the building,we recommend using a plumb line on the eaves and making regular checks of theconstruction width.

    RIB-ROOF 465INSTALLATION

    3.2

    Page 34 Zambelli Practical Guide RIB-ROOF

    Start clip 1.

    2.

    3.

  • 8/11/2019 zambelli planificare instalare

    37/88

    Use an anchor point for each profile sheet to prevent it from slipping down. Forpitches 15, higher snow loads and profile sheetsover 33m please contact Zambelli.Now fasten the next row of clips from an angle of > 90 to the fastening level tothe rear edging of the bare small rib of the profile sheet from above and swivelthe profile sheet down onto the substructure. Click the clips into place in thelongitudinal bead of the rib and fasten them onto the substructure.

    Insert next profile sheet

    Click the large and medium-sized rib of the second profile sheet onto the firstprofile sheet and the exposed part of the clip. Using the zipper method, proceedfrom the eaves point to the ridge. Clicking into place is normally done by well-aimed accessibility (aid: wood border with milled groove).The moulded longitudinal beads ensure that the longitudinal joints are rainproofonce they have been clicked into place. Mechanical joining or manual processingis not required.

    RIB-ROOF 46INSTALLATIO

    Zambelli Practical Guide RIB-ROOF Page 35

    4.

    Anchor point onto the little rib

    (as an alternative: Anchor point ontothe big rib, together with the fixationof the closure.)

  • 8/11/2019 zambelli planificare instalare

    38/88

    RIB-ROOF 465CURVED PROFILE SHEE

    Page 36 Zambelli Practical Guide RIB-ROOF

    Curved profile sheets RIB-ROOF 4653.3

    It is possible to construct the roof with

    Radii from > 6m on (RIB-ROOF Speed 500from r >2m on) without counter lathingwhen a wooden lateral lathing or ametallic Z-profile or a domed profile isused. Smaller radii on demand.

    Roof constructionPossible for radii > 8.0 m for a

    wooden counter and lateral lathing

    RIB-ROOF curvedThermal insulation with interveninglateral and counter lathingVapour barrierTrapezoidal sheet metalTruss

  • 8/11/2019 zambelli planificare instalare

    39/88

    RIB-ROOF 46CURVED PROFILE SH

    Zambelli Practical Guide RIB-ROOF Page 37

    The following minimum bending radii must be taken into consideration formechanical cambering; they depend on the type of material and thickness [t]:

    For smaller radii, conical curved and concave profile sheets please ask Zambelli.

    For radii over 60m the profile sheets can be curved without a machine and fixedwith a sliding clip. As during the forced curving on-site the profile sheets have tobe pushed onto the radius, dents can sometimes not be avoided. The curving bymachine is the optical better solution.

    Table of minimum bendingradii of different metals

    Minimum bending radiiconvexe Profile sheets RIB-ROOF 465

    Material Material thickness [t] Radius[mm] [m]

    Steel 0.63 6.00Aluminium 1.00 6.00Aluminium 0.80 or 0.90 10.00Aluminium 0.70 15.00Titanium zinc 1.00 on demandCopper 0.60 on demand

  • 8/11/2019 zambelli planificare instalare

    40/88

    Spans clip distancesfor enclosed hall-type buildings

    Sheet steel 0.63 7.40 2.46 1.38 1.70

    0.75 8.40 2.80 1.57 2.500.88 8.40 2.80 1.57 3.00

    Aluminium 0.70 3.00 1.00 0.65 1.200.80 3.93 1.31 0.73 1.500.90 4.40 1.47 0.82 1.701.00 4.90 1.63 0.91 1.90

    Sheet steel 0.63 4.62 1.54 0.86 1.700.75 5.25 1.75 0.98 2.500.88 5.25 1.75 0.98 3.00

    Aluminium 0.70 1.87 0.62 0.35 1.200.80 2.45 0.82 0.46 1.500.90 2.75 0.91 0.51 1.701.00 3.06 1.02 0.57 1.90

    Height of building h > 8.00m < 20.00m

    RIB-ROOF 465SPANS

    CLIP DISTANCES

    Height of building h < 8.00m

    Page 38 Zambelli Practical Guide RIB-ROOF

    3.4

    Material Material thickness Clip distance Clip distance Clip distance max. span ofaccessibility deter-

    (mm) Normal area (m) Edge area (m) Corner area (m) mined by installation

    wind loads according to DIN 1055 part 4: w=0.48kN m2 w=1.44kN m2 w=2.56kN m2

    Material Material thickness Clip distance Clip distance Clip distance max. span ofaccessibility deter-

    (mm) Normal area (m) Edge area (m) Corner area (m) mined by installation

    wind loads according to DIN 1055 part 4: w=0.30kN m2 w=0.90kN m2 w=1.60kN m2

  • 8/11/2019 zambelli planificare instalare

    41/88

    Table showing spansor clip distances

    RIB-ROOF 46SPANS

    CLIP DISTANC

    Height of building h > 20.00m < 100.00m

    Sheet steel 0.63 3.36 1.12 0.63 1.70

    0.75 3.81 1.27 0.71 2.500.88 3.81 1.27 0.71 3.00

    Aluminium 0.70 1.36 0.45 0.25 1.200.80 1.78 0.60 0.33 1.500.90 2.00 0.66 0.37 1.701.00 2.22 0.74 0.41 1.90

    Zambelli Practical Guide RIB-ROOF Page 39

    We would be pleased to assist you in calculating the clip distances (or spans) fora specific building. The summary values of the fastening agents you choose for

    the respective substructure must be inspected. Please contact us.

    The maximum accessibility span for titanium zinc is 0.60m for multiple-span andsingle-span girders. Full surface support or corresponding substructures are required.The maximum accessibility span for copper is 1.20 m.

    The width of the edge and corner area is the respective width of the buildin a 8in accordance with DIN 1055 Part 4.

    The edge and corner are consequently at least 1m and may be limited to 2m width

    for residential and office buildings and enclosed hall-type buildings with a 30 m.

    The wind loads were taken into consideration according to DIN 1055 part 4.

    Material Material thickness Clip distance Clip distance Clip distance max. span ofaccessibility deter-

    (mm) Normal area (m) Edge area (m) Corner area (m) mined by installation

    wind loads according to DIN 1055 part 4: w=0.66kN m2 w=1.98kN m2 w=3.52kN m2

  • 8/11/2019 zambelli planificare instalare

    42/88Page 40 Zambelli Practical Guide RIB-ROOF

    Installation technique Roof covering in generalPro contra open diffusion protective sheetor compressed thermal insulation

    ZVSHK leaflet Ventilated and unventilated metal roofs manufactured from industrialpre-fabricated lock seam profiles

    With the metal roof system RIB-ROOF you generally have the possibility of constructingboth the variation with the open diffusion protective sheet and the variation withcompressed thermal insulation. As you will gather from the ZVSHK leaflet Ventilatedand unventilated metal roofs manufactured from industrial pre-fabricated connectingend profiles, the ZVSHK (Central Association for Sanitation, Heating, Air Conditioningrecommends both types of construction. In individual cases, you can weigh thepros and contras of the two types and discuss them with the developers andarchitects. For economic reasons, the design with compressed thermal insulationhas also proved its worth during recent years in addition to the open diffusionprotective sheet which has been tried and tested for over two decades.

    Pro contra open diffusion protective sheetRun off of water produced on thawing to the eaves on the protective sheet, alsoduring back pressure due to extreme ice snow conditions in the eaves

    makes heavy demands on the layer to prevent potential water pocket formationCosts

    Pro contra compressed thermal insulationless air space so formation of condensation minimised

    Improved noise protection

    Back pressure in the eaves possible during extreme ice snow conditions withpotential humidification of the thermal insulation (solution is a protective sheetwith a width of approx. 3m parallel to the eaves, or installation of additional rowsof snow fences in accordance with Practical Guide Chapter 5.9.)

    44.1

    Pro

    Contra

    Pro

    Contra

    INSTALL. TECHNIQUOPEN DIFFUSION

    PROTECTIVE SHEE

  • 8/11/2019 zambelli planificare instalare

    43/88Zambelli Practical Guide RIB-ROOF Page 41

    Your RIB-ROOF regional sales manager will be pleased to answer individual queriesto assist you in choosing the protective sheet with open diffusion or the compressedthermal insulation.

    Brief summary of the additional benefits of the RIB-ROOF metal roof systemrelating to the above topics:

    RIB-ROOF metal roof system now gives you the practical choice of installing theopen diffusion protective sheet on the mineral wool since with RIB-ROOF the clipsare fastened from above through the protective sheet into the substructure andthe protective sheet does not have to be penetrated below the clips already installedby tearing the foil.

    For non-insulated roofs (with vapour barrier Sd value >100m) you will obtainthe best U values with a distance structure (which is convenient forinstallation purposes), from lateral and counter lathing at a distance of1.19m in the normal area and intervening mineral wool insulation. The very

    good U values attainable with in contrast to metallic distance structures havebeen documented in the scientific research conducted by the FIW Forschungs-institut fr Wrmeschutz e.V. Mnchen, (enclosed in your architect file).

    Metallic distance structures with Z profiles or with system sliding clips requirecorresponding reinforcement of the thermal insulation (costs) in order to attain thesame U value.

    Saving of energy costs with a wooden lathingAccording to the examination report of the FIW of 11 April 2005 you can save

    about 1,300 per year and 1,000m 2 roof surface if you use a wooden distanceconstruction and not a metallic Z-profile. You can save energy costs of about

    540 per year for the same surface against the metallic brackets which aregoing through the termal insulation.

    1.

    2.

    INSTALL. TECHNOPEN DIFFUSIO

    PROTECTIVE SH

  • 8/11/2019 zambelli planificare instalare

    44/88Page 42 Zambelli Practical Guide RIB-ROOF

    4.2

    1.

    2.

    3.

    4.

    INSTALLATION TECHNIQOPEN DIFFUSION PROTECTIVE S

    LAYING TECHNIQU

    3. The RIB-ROOF lock seam profile is more diffusion open than mechanically beadedsystems or conventional angled or double standing seam covers. The followingmedian values are given as Sd values in the corresponding study Determinationof Water Vapour Permeability by the FIW Research Institute, registered societyin Munich for RIB-ROOF Speed 500, median Sd value of 12.8m, for aluminium0.70mm; for RIB-ROOF 465 median Sd value of 25.7m, for aluminium 0.90mm(as a comparison: mechanically beaded system median Sd value of 30.6m, for

    aluminium 0.90mm). Moreover, with RIB-ROOF the seam cavities and the opendiffusion roof edge son the ridge, eaves and verge flashing facilitate an additionalexchange of air and an additional diffusion effect as a result.

    Laying technique

    Important basic rules for installation

    Installation must be halted during extreme weather conditions and individual profilesheets must be fastened or secured immediately. Since RIB-ROOF does not requirebeading, it may also be installed during low outdoor temperatures.

    Please see the tables in Chapter 2.5 and 3.4 for accessibility of profile sheets duringinstallation (maximum span of accessibility determined by installation).

    Inform other workmen before they access the roof that load distributing elementsmust be laid in the accessible areas in order to prevent deformations or damage

    to the sheets. Joining the profile sheets to rising components necessitates bevelling the bottomflange prior to installation (available from the works), see Chapter ridge area 5.1.

  • 8/11/2019 zambelli planificare instalare

    45/88Seite 1

    Terraced gradients are used as adecorative element in architecture

    The eaves side profilesheets must also be fixedwith anchor points.

    Zambelli Practical Guide RIB-ROOF Page 43

    INSTALL. TECHNITERRACED GRAD

    Terraced gradient

    Terraced gradients are used in architecture as a decorative element or for extremeprofile sheet lengths. The detailed construction of the single pitch roof ridge tothe rising wall basically applies here. The terraced gradient must be protectedfrom penetration by driving rain through installation of an eaves row.

    4.3

  • 8/11/2019 zambelli planificare instalare

    46/88Page 44 Zambelli Practical Guide RIB-ROOF

    Transverse joint

    Profile sheet transverse joints are not required as a rule since longitudinalexpansion of the material is taken up by the fastening elements (clip). Forextra long lengths that are not to be transported by lorry (>33m), the sheetsmay be profiled at the building site (see Chapter 1.4.1 Transport).

    If transverse joints are still required, welded finishes with aluminium profile sheetsare chosen as far as possible. In exceptional cases and only for pitches >7,transverse joints with tight rivets and sealing material are finished (in accordancewith the following illustrations); their use requires great precision.

    Cutting out joint overlap andinstallation sequence: The numbersof the profile sheets reflect the layingsequence.

    = Anchor point

    4.4

    INSTALL. TECHNIQUTRANSVERSE JOINT

  • 8/11/2019 zambelli planificare instalare

    47/88Zambelli Practical Guide RIB-ROOF Page 45

    INSTALL. TECHNTRANSVERSE JO

    Normally we deliver continuous (from the ridge to the eaves)profile sheets without any limit in the length.

    Alternatively, you can also make a transverse joint foraluminium profile sheets

    Exceptionally and only when the pitch is >7, transverse jointscan be done with tight rivets and sealing material.

    Cut (notching)

    Required cut (notching)on the joint overlap

    Finish with tight rivets anda sealing strip or siliconsealing material insert

  • 8/11/2019 zambelli planificare instalare

    48/88

    INSTALL. TECHNIQUSEALING THE LONGITUDINAL J

    DETAIL STRUCTUR

    Page 46 Zambelli Practical Guide RIB-ROOF

    Sealing the longitudinal joint

    For pitches

  • 8/11/2019 zambelli planificare instalare

    49/88Seite 1

    DETAIL STRUCTU

    Zambelli Practical Guide RIB-ROOF Page 47

  • 8/11/2019 zambelli planificare instalare

    50/88

    Ridge area

    Important: Before attaching the ridge cap or ridge side connection sheet to therising components, the anchor points for the profile sheets must be inspected.

    5.1

    DETAIL STRUCTURRIDGE AREA

    Page 48 Zambelli Practical Guide RIB-ROOF

  • 8/11/2019 zambelli planificare instalare

    51/88

    The large rib on the profile sheets is cut off for RIB-ROOF 465at its exposed seam end at a 45 angle.

    After installing the elements, the water carrying bottom chord must be bendedwith the bevelling tool or pliers (illustration above), to prevent penetration ofrainwater and snowdrift. This step must be carried out when rising components(e.g. walls, row of windows) are connected and before laying in any event.

    Alternatively, the bending upwards of the bottom chord at the ridge can also becarried out in the factory.

    The opposite expansion of the profile sheet and ridge cap require immediatefastening using indented sheets. These are aligned on both sides (saddleback ridge)or on one side (single pitch roof, wall or connection to the row of windows) witha line or distance gauge and fastened onto the structural ribs with blind rivets orself-drilling screws.

    The large rib on the profile sheetis cut off at its open seam end at

    an angle of 45 (for RIB-ROOF 46

    Bending the bottom chord at thebuilding site with bending tool

    Zambelli Practical Guide RIB-ROOF Page 49

    Ridge side bended of thebottom chord, eaves sideedging of the profilesheets also possible at theworks. Direction of layingfrom left to right.

  • 8/11/2019 zambelli planificare instalare

    52/88

    Saddleback ridge

    The saddleback ridge without ventilation (for single-shelled roof structure, warmroof) is inserted with its double face back edging (bend with approx .10mm radius)in the indented sheets and pressed together with the seam. The cross connectionis manually seamed or attached to the expansion devices with blind rivets.

    Profile fillers are installed as required. The structure and distance of expansiondevices must be taken into consideration in any event.

    Ridge cap saddleback roof

    5.1.1

    DETAIL STRUCTURRIDGE AREA

    Page 50 Zambelli Practical Guide RIB-ROOF

    Underlay sheet (optional)ClosureAnchor pointsReinforcing sheetfor anchor pointsRetaining clipRidge sheetRIB-ROOF

    Thermal division

  • 8/11/2019 zambelli planificare instalare

    53/88

    Saddleback ridgewith air vent

    The saddleback ridge with air vent (fordouble-shelled roof structure, single pitchroof) is a standard product from our rangeof accessories and available in all materialsaccording to the roof covering as a kit withtwo integrated ventilation indented borders andprofile fillers.

    Ridge sheetIntegrated ventilation closureand profile fillerRetaining clip with anchor pointRIB-ROOF

    DETAIL STRUCTURIDGE ARE

    Zambelli Practical Guide RIB-ROOF Page 51

  • 8/11/2019 zambelli planificare instalare

    54/88

    Single pitch roof ridge

    The single pitch roof ridge (with without air vent) is very similar to the vergeflashing described in Chapter 5.3 and together form a unified whole for the purposesof design and technical installation. To avoid deformations to the ridge trim, agalvanised steel profile at least 1.0mm thick must be laid under the trim.

    5.1.2

    DETAIL STRUCTURRIDGE AREA

    Single pitch roof coveringClosureAnchor pointRetaining clipRetaining sheetShutteringDividing layer

    Ridge cap single pitch roof

    RIB-ROOF

    High open diffusionUnderlay sheet (optional)

    Page 52 Zambelli Practical Guide RIB-ROOF

  • 8/11/2019 zambelli planificare instalare

    55/88

    Sing pitch roof ridge on rising wall ( wall connection ridge side; with withoutvent). The height of bending with a water seam depends on the pitch, but isgenerally at least 15cm above the level of the bottom flange of the profile sheet.

    Single pitch roofridge with vent

    Single pitch roof covering, in two parts

    Supporting angleInsertion sheet

    Indented border for ventilationRetaining clip

    RIB-ROOF

    Single pitch roof covering,in two parts

    Retaining angle

    DETAIL STRUCTURIDGE ARE

    Zambelli Practical Guide RIB-ROOF Page 53

    Air

  • 8/11/2019 zambelli planificare instalare

    56/88

    When joining to the brick masonry or plaster facade, an overhang strip must be( plaster border) in accordance with illustration in Chapter 5.4 must cut into thewall, backed with a sealing strip or permanently elastic filling agent and pressedon with a screw connection. The overhang strip must be attached before theplastering work is carried out.

    Facade profileRetaining clip

    ClosureWall connection

    Edge angleRIB-ROOF

    High open diffusionUnderlay sheet (optional)

    Anchor pointDomed profile

    DETAIL STRUCTURRIDGE AREA

    Single pitch roof ridge on risingwall with full thermal insulation

    (Wall connection ridge side)

    Page 54 Zambelli Practical Guide RIB-ROOF

  • 8/11/2019 zambelli planificare instalare

    57/88

    Arris area

    Arises are finished in a similar manner to the saddleback ridge. The factory doesnot provide the indented plates with the notches for the profile sheet ribs ( raisedbeads). These notches are marked at the site and cut out with metal plate shearsin order to obtain an optimal fit.

    The construction details for the ridge cap are basically applicable here.

    5.2

    DETAIL STRUCTU ARRIS ARE

    Zambelli Practical Guide RIB-ROOF Page 55

  • 8/11/2019 zambelli planificare instalare

    58/88

  • 8/11/2019 zambelli planificare instalare

    59/88

    Installation of a verge flashing plank as a support and a stop plate on the facadeis recommended for all constructions in order to avoid material tensions whichwould manifest in the formation of undulations and other unsightly deformationsof the verge flashing trim.

    The cross connection for the verge flashing trim is franked manually or is done withsplice plates.

    Verge flashing projection

    Verge flashing insert profileVerge flashing covering

    Underlay sheet withhigh open diffusion (optional)Retaining clipRIB-ROOF

    Support

    DETAIL STRUCTUVERGE FLASHING A

    Edge profileStop plate

    Zambelli Practical Guide RIB-ROOF Page 57

    Trapezoidal sheet metal-profilefiller to avoid a thermal bridge

  • 8/11/2019 zambelli planificare instalare

    60/88

    Lateral wall connection

    In metal, brickwork and other facade structures, the lateral wall connection isinstalled in a parallel or conical design onto the profile sheets.

    The detail structuring of the verge flashing also basically applies here. For joiningto visible concrete, brick masonry or plastered walls, the overhang strip (plasterborder) must be applied as described in Section 5.1 (single pitch roof on risingwall). For pitches below 25, the connecting height should not be below 15cm.

    The lateral connection to a fascia requires a two-part connection. Fastening to theprofile sheets must be done as described above. The flashing must be splicedmanually in the re-edging of the lateral connection with a conically cut plate.

    Lateral wall connectionto brick masonryor plaster facade

    5.4

    RIB-ROOFRetaining clipOpen diffusionunderlay sheet (optional)

    Sealing jointOverhang strip (plaster border)Wall connectionInsert profile

    DETAIL STRUCTURLATERAL WALL CONNECT

    Page 58 Zambelli Practical Guide RIB-ROOF

  • 8/11/2019 zambelli planificare instalare

    61/88

    Eaves area

    There are a wide variety of gutter solutions that are used in different countries andregions. It is not intended to present a detailed description of them here.

    The gutter which is inserted externally is the simplest eaves construction. The classicgutter in semi-circular or box form is fastened to the eaves plank with the gutterhooks. The requirements for the installation technique in accordance with DIN 18339 plumbing have been outlined. For ventilated roof structures, construction of anair inlet opening (at least 4cm clear opening) below the eaves is recommended.Installation of profile fillers in the eaves area is only required in exceptional cases.

    The eaves plate ( gutter inlet sheet) is the connection of the roof to the gutterand should be measured on a scale of 333mm.

    Model constructionroof overhang

    5.5

    half-round gutterEaves angle forRIB-ROOF Speed 500

    Gutter inlet sheetRetaining clipHigh open diffusionprotective sheetEaves rafterRafter lining

    DETAIL STRUCTUEAVES ARE

    The roof overhang can alsobe effected alternativelywith an overhanging clip barwhen RIB-ROOF Speed 500is used.

    Zambelli Practical Guide RIB-ROOF Page 59

  • 8/11/2019 zambelli planificare instalare

    62/88

    The protective sheet with high open vapour diffusion or other dividing layers coverthe eaves plate in order to divert secondary water produced by thawing which mayoccur in the gutter. The gutter distance of the profile sheets is shown in theillustrations on pages 59 and 60 (at least 30mm). After installation of the sheets,the water carrying lower flange must be aligned with the gutter using the bevellingtool (illustration page 59).Detail box gutter with snow

    fence and ice stop device

    DETAIL STRUCTUREAVES AREA

    Page 60 Zambelli Practical Guide RIB-ROOF

    Ice retainerSnow fence pipe 32mmCollarHigh open diffusionunderlay sheet (optional)

    RIB-ROOFPlankingAir rafterRetaining clip

    GutterGutter pitch plate

    Eaves angle for RIB-ROOF Speed 500

    The eaves angle is nottechnically required forRIB-ROOF 465.

    Eaves security against the wind load

    The eaves security against the higher wind loads at the eaves is done when theknuckles are overlapped according to the illustration.

    Read also in chapter Terraced gradient.

    wind suction safetyat the overlapping bead

    riveted

  • 8/11/2019 zambelli planificare instalare

    63/88

  • 8/11/2019 zambelli planificare instalare

    64/88

    Gutter supports welded in two partswith conical inlet

    Non-slip thermal insulation

    Box type gutter

    Water carrying gutterSafety gutter

    Gutter pitch plateAdhesives for

    sliding fastenersShuttering

    Trapezoidal sheet metalVapour barrierThermal insulationLateral and counter lathingHigh open diffusionunderlay sheet (optional)Retaining clipRIB-ROOF

    DETAIL STRUCTURBOX TYPE GUTTER

    Page 62 Zambelli Practical Guide RIB-ROOF

  • 8/11/2019 zambelli planificare instalare

    65/88

    Wood plank

    Adhesive for sliding fasteningSupporting safety gutter

    Fascia with wall connectionand fascia gutter

    Stop plateFascia wood plankDividing layerFasciaFascia connecting plateGutter heatingNon-slip thermal insulation

    Water carrying gutter

    Thermal insulationCounter lathing

    Trapezoidal sheet metalVapour barrier

    high open diffusion under-lay sheet with (optional)

    Cross lathingRetaining clip

    RIB-ROOF

    DETAIL STRUCTUBOX TYPE GUT

    Zambelli Practical Guide RIB-ROOF Page 63

  • 8/11/2019 zambelli planificare instalare

    66/88

    Flutes

    Flutes structure is dependent on the length and gradient. The latter is generallysmaller than the adjacent pitch.

    Flutes should be constructed with a greater depth for roof structures with a pitch 7.

    Sunk flute with double-sidedinsert plate

    5.7

    clamps forgliding fasteningFlute insert plateFlute gutter

    RIB-ROOFRetaining clipHigh open diffusionunderlay sheet (optional)

    DETAIL STRUCTURFLUTES

    Page 64 Zambelli Practical Guide RIB-ROOF

  • 8/11/2019 zambelli planificare instalare

    67/88

    5.8

    The load-bearing capacityof the support structure,if necessary withappropriate structuralreplacements, must bechecked in individualcases and is not describedin more detail here.

    DETAIL STRUCTUROOF PENETRATIO

    Zambelli Practical Guide RIB-ROOF Page 65

    Roof penetrations

    Roof penetrations and their curbs are constructed manually according to the materialor welded soldered watertight. They require great care and expertise in plumbingtechnique.

    As the leaflet Bonding in plumbing technique by the ZVSHK (ZentralverbandSanitr Heizung Klima) in 53757 St. Augustin states, bonding of metal materialsis also a potential alternative in plumbing technique. Single-component polyurethanebonding agents are normally used in plumbing technique.

    Water drainage and longitudinal expansions of the profile sheets in the penetrationarea must be ensured by taking the appropriate steps. The height of the curbsdepends on the pitch, but is generally not less than 15cm.

  • 8/11/2019 zambelli planificare instalare

    68/88

    Round roof penetrations

    Round roof structures are sealed with pre-fabricated conical connection pieces (tightrivets and silicon sealing, Soft or hard soldering, welding, bonding).

    Top sealing is done with a collar which projects over the connection pieces.

    The substructure must be temporarily protected with suitable materials (protectivesheets) when a connection is hard soldered or welded due to the fire hazard (wood)and damage.

    5.8.1

    DETAIL STRUCTURROOF PENETRATIONS

    Page 66 Zambelli Practical Guide RIB-ROOF

  • 8/11/2019 zambelli planificare instalare

    69/88

    Roof domewith plug-in connection

    Pipe coverInsulation

    Retaining clip

    Pipe

    RIB-ROOFHigh open diffusionunderlay sheet (optional)Welding seam continuousThermal insulation(double-layered)

    Vapour barrierTrapezoidalsheet metal

    Pipe

    Lateral and counter lathing

    Roof dome with plug-in connectionRetaining clipLateral andcounter lathing

    RIB-ROOFHigh open diffusion

    Thermal insulation(double-layered)Welding seamcontinuous

    underlay sheet (optional)

    DETAIL STRUCTUROOF PENETRATIO

    Room ventilation pipe welded

    Construction with roof dom

    Room ventilation pipe weldedFinish with roof dome

    Zambelli Practical Guide RIB-ROOF Page 67

    Trapezoidalsheet metalVapour barrier

  • 8/11/2019 zambelli planificare instalare

    70/88

    Sanitary ventilation pipeConstruction sealed

    The maximum external diameter without structuring the back for water drainageis 300mm for RIB-ROOF Speed 500, 160mm for RIB-ROOF 465.

    The seam of two-part pipe covers must lie in the vertical axis of the gap.

    RIB-ROOFHigh open diffusionunderlay sheet (optional)Thermal insulation

    Pipe coverInsulationPipe connection plate

    Tight rivets, sealing strip andsilicon sealing continuous

    (alternatively bonding),

    Pipe

    RIB-ROOFHigh open diffusion

    underlay sheet (optional)Thermal insulation

    Retaining clip

    DETAIL STRUCTURROOF PENETRATIONS

    Page 68 Zambelli Practical Guide RIB-ROOF

    Sanitary ventilation pipeConstruction sealed

    Lateral andcounter lathing

    Tight rivets, sealing strip andsilicon sealant continuous

    (alternatively bonding)

    Lateral andCounter lathing

  • 8/11/2019 zambelli planificare instalare

    71/88Zambelli Practical Guide RIB-ROOF Page 69

    Domelight curb

    Domelight curbDomelight coverInsert profileWood support

    RIB-ROOFHigh open diffusionunderlay sheet (optional)Thermal insulation (double layered)Retaining clip

    Wood plank edgeTrapezoidal profile cover

    Steel support

    5.8.2

    Vapour barrierTrapezoidal profile

    Curb for domelightSmoke funnel and heat ventilation equipment

    Welding the curb:The profile sheet ribs are separated in the dead centre in the area of the ridgeand eaves in a length of approx. 30cm at the culminating point, the two planksoverlap and the resultant seam and rib openings are welded or soldered,depending on the material.

    The requirements for loaddissipation in Section 5.8basically apply here. Thecurb can only be fastenedto the substructure if theanchor points of theprofile sheets are alsoarranged in this area.

    Structuralreplacement

    DETAIL STRUCTUROOF PENETRATIO

    Lateral and

    counter lathing

  • 8/11/2019 zambelli planificare instalare

    72/88

    Domelight cover with backdraught safeguard for pitches

    from 3 to 15

    The following steps must be followed for larger dimensions and if watertightwelding soldering or curbs for sealing are dispensed with:

    Raising the flow of water behind the penetration above the level of the profilesheet ribs by installing a double standing seam cover on the correspondingsubstructure (e.g. wood shuttering with dividing layer).

    Raising the flow of water above the level of the profile sheet ribs by installingincreased distance structure (e.g. lateral wood lathing) in the back area of thepenetration and insertion of the raised RIB-ROOF sheets under the ridge cap.

    The resultant lateral openings must be covered manually with plates cut in a conicalshape (illustration page 71).

    Retaining clip

    Domelight curbDomelight coverWood plank edgeIndented groove

    Domelight curbDomelight gutter plate

    Insert plateEaves angle

    Dividing layerShuttering

    Steel support

    High open diffusionunderlay sheet (optional)

    DETAIL STRUCTURROOF PENETRATIONS

    Page 70 Zambelli Practical Guide RIB-ROOF

    Structuralreplacement frame

    Trapezoidal profile- andWood plank edge-curb

  • 8/11/2019 zambelli planificare instalare

    73/88

    RIB-ROOFHigh open diffusion

    underlay sheet (optional)Thermal insulation

    Lateral and counter lathingVapour barrier

    Trapezoidal profile Zambelli Practical Guide RIB-ROOF Page 71

    DETAIL STRUCTUROOF PENETRATIO

  • 8/11/2019 zambelli planificare instalare

    74/88

    5.8.3 Rectangular roof penetrations

    Rectangular roof penetrations (chimney-roof area windows-domelight) are coveredmanually with a rear endplate ( flute- neck plate formation dead centrewith edge placed higher to the water pipes on both sides) left and right lateralplate and a lower covering plate ( breast plate) are covered manually andintegrated into the roof areas. The height of the curbs must be continuously at least15cm above the profile sheet surface.

    Page 72 Zambelli Practical Guide RIB-ROOF

    DETAIL STRUCTURROOF PENETRATIONS

  • 8/11/2019 zambelli planificare instalare

    75/88

    For pitches >15, simple covering of the back plate by the profile sheets suffices.

    For pitches

  • 8/11/2019 zambelli planificare instalare

    76/88

    Chimney mantel(eaves and ridge side)

    Sealing compoundProjection strip

    Indented grooveBorder plateeaves side

    Back draught safeguardfor pitch >15

    Thermal insulations(single layered)Z profile (cross)thermal division

    Sealing stripRetaining clipAdhesive stripEdge cubInsert plate on the backProfile filler

    Vapour barrierTrapezoidal sheetmetal

    RIB-ROOFHigh open diffusion

    underlay sheet (optional)

    DETAIL STRUCTURROOF PENETRATIONS

    Page 74 Zambelli Practical Guide RIB-ROOF

    Steel purlinEdge border

  • 8/11/2019 zambelli planificare instalare

    77/88

    Roof area windows

    For pitches >15, construction with sealed frame is sufficient. The curb isintegrated in its overlapping RIB-ROOF elements in the roof area.

    The back profile sheet cover must be finished in accordance with Section4.4 Transverse joint.

    5.8.4

    Zambelli Practical Guide RIB-ROOF Page 75

    DETAIL STRUCTUROOF PENETRATIO

  • 8/11/2019 zambelli planificare instalare

    78/88

    The sheets that are adapted to the gutter must be bevelled in the lower flangeand fixed with anchor points to prevent them. This area is covered by the pre-fabricated breast plate of the curb. The profile sheet transverse joints are sealedas described above.

    High open diffusionunderlay sheet (optional)

    overlapping wood plank edgeRoof window casingRIB-ROOFRetainingclip

    Interior liningWindow frame

    Page 76 Zambelli Practical Guide RIB-ROOF

    DETAIL STRUCTURROOF PENETRATIONS

  • 8/11/2019 zambelli planificare instalare

    79/88

    Anchor point

    overlapping plank edgeIndented grooveRoof window casing

    RIB-ROOF

    Retaining clip

    In the pitch area >1.5, welding or soldering of the curbs is required, dependingon the materials. When covering the roof, the profile sheets are laid on the flangeof the curbs and the overlapping joints are either tightly welded or soldered. Theprofile ribs facing the eaves on the back are sealed with the same technique.

    High open diffusion underlay sheet (optional)Roof window casing

    Zambelli Practical Guide RIB-ROOF Page 77

    DETAIL STRUCTUROOF PENETRATIO

  • 8/11/2019 zambelli planificare instalare

    80/88

  • 8/11/2019 zambelli planificare instalare

    81/88

    Snow fence, ice shield devices, mounted bracketfor solar module and harness security system

    Snow fence devices are fastened onto the ribs of the profile sheets with system-specific collars without perforating the profile sheets. They stop the thrust of thesnow lying on the roof and prevent it falling off.

    5.9

    DETAILKONSTRUKSNOW ICE SOL

    HARNESS SECURITY S

    Zambelli Practical Guide RIB-ROOF Page 79

    The solar module support,aluminium model,uncoated, may also beused as a lightningconductor terminal inaccordance with DIN EN50164-1, Testing Class N.

    Solar module support

  • 8/11/2019 zambelli planificare instalare

    82/88

    You can calculate the per-mitted wind load F Z=0.5kNper one solar module sup-port. To ensure the longitu-dinal expansion, the solarmodule supports should notbe installed directly in thearea of the sliding clips. Theprescribed starting torquefor the screws is 15Nm.

    DETAILKONSTRUKTIOSNOW ICE SOLAR

    HARNESS SECURITY SYST

    The photovoltaic system onsolar module supports RIB-ROOF

    Page 80 Zambelli Practical Guide RIB-ROOF

    photo: BP Solar

  • 8/11/2019 zambelli planificare instalare

    83/88

    The sheets of ice that frequently occur when and after the snow thaws are preventedfrom slipping below the snow fence pipes (external diameter 32mm) by theinstallation of ice shields (photo p. 79 or illustration on pages 82 and 83). Werecommend the aluminium finish (for TECU profile sheets copper snow fence andice shields are available) since the use of corrosion resistant materials can lead tounsightly rust formation on the cut edges of the pipes.

    The screws (at least M8x40mm) should be made of rust-resistant material. Theprescribed starting torque for the screws is 15 Nm.

    The quantity and distances of the snow fence pipes (see following table) dependon the pitch and local weight of snow.

    The thrust produced by the snow lying on the roof may be distributed amongseveral rows of snow fences. Double snow fence pipes are no longer used.

    Table with distances betweenthe rows of snow fences

    Distances between the rows of snow fences

    Weight of snow S i 5 10 15 20 25 30 35

    0.75 kN m2 22.12 11.06 7.42 5.60 4.