Steps in installing X-CTU software:

1. Getting X-CTU :

X-CTU was developed by Digi and it is only available for Windows

2 . Installing X-CTU :

Once X-CTU has been downloaded

The next step is installing the program.

3 .Configuring X-CTU :

When X-CTU has been properly installed, the Wasp mote Gateway can be connected to the

computer.

It will be recognized as a ‘USB Serial Port’ 

Page 3: X CTU Installation

7/28/2019 X CTU Installation

http://slidepdf.com/reader/full/x-ctu-installation 3/16

Finally, we launch X-CTU and the program will start.

A window like the one below will appear, showing the different functions and the

different COM detected.

Page 4: X CTU Installation

7/28/2019 X CTU Installation

http://slidepdf.com/reader/full/x-ctu-installation 4/16

If Wasp mote Gateway COM does not appear automatically, we must add it

manually.

To add a COM port we have to stay in ‘PC Settings’ tab, and change to ‘User Com

Ports’ tab.

There is a little box to add Com Ports, so we will add the port as is shown below

Page 5: X CTU Installation

7/28/2019 X CTU Installation

http://slidepdf.com/reader/full/x-ctu-installation 5/16

4 . Details for the X-CTU operation:

4.1 – Place the XBee you need to configure in the Gateway. Then connect the

Gateway to a USB port in your PC

4.2 – Open the X-CTU application, select the appropriate communication port and

configure it as shown in next slide

Page 6: X CTU Installation

7/28/2019 X CTU Installation

http://slidepdf.com/reader/full/x-ctu-installation 6/16

Page 7: X CTU Installation

7/28/2019 X CTU Installation

http://slidepdf.com/reader/full/x-ctu-installation 7/16

4.3 – Perform the test (there is a button for that) and check the application delivers a

message similar to this one

It is possible that X-CTU asks you to do a reset of the XBee in this step (or in the nextsteps). To do that, just press the button “RST” in your Gateway for 1 or 2 seconds  

Page 8: X CTU Installation

7/28/2019 X CTU Installation

http://slidepdf.com/reader/full/x-ctu-installation 8/16

4.4 – Then go to the Modem Configuration tab, and select the ‘Read’ option.

We must check each parameter first

Page 9: X CTU Installation

7/28/2019 X CTU Installation

http://slidepdf.com/reader/full/x-ctu-installation 9/16

4.5 – Check the first parameter, CH

Page 10: X CTU Installation

7/28/2019 X CTU Installation

http://slidepdf.com/reader/full/x-ctu-installation 10/16

4.6 – The PAN ID

Page 11: X CTU Installation

7/28/2019 X CTU Installation

http://slidepdf.com/reader/full/x-ctu-installation 11/16

4.7 – The destination address (2 parts)

Page 12: X CTU Installation

7/28/2019 X CTU Installation

http://slidepdf.com/reader/full/x-ctu-installation 12/16

4.8  – The KY parameter (if needed). It must be set as hexadecimal key

Page 13: X CTU Installation

7/28/2019 X CTU Installation

http://slidepdf.com/reader/full/x-ctu-installation 13/16

4.9 – The serial interface baud rate

Page 14: X CTU Installation

7/28/2019 X CTU Installation

http://slidepdf.com/reader/full/x-ctu-installation 14/16

4.10 – The API options

Page 15: X CTU Installation

7/28/2019 X CTU Installation

http://slidepdf.com/reader/full/x-ctu-installation 15/16

5 – If you have networking problems, please check these tips:

All XBees are in the same network that the Gateway (or Meshlium). In Waspmote’s API, PAN

ID parameter is set with setPAN function. You can also set this parameter for each XBee

plugging it to the Gateway, and then connecting it to a PC: the Digi’s X-CTU application helps to

check and set the XBee’s configuration. In this case, you must use the ATID command.  

All XBees are in the same channel. The CHANNEL parameter is set with set Channel function.

If you want to do it in the X-CTU way, you must use the ATCH command.

All Waspmotes are transmitting towards the MAC of the Gateway (or Meshlium).

All XBees are configured to 115200 bps (in Waspmote PRO). In X-CTU, you can control data

baud rates executing the ATBD command.

All XBees have the same encryption options. The ENCRYPTION MODE parameter is set withset Encryption Mode function. In X-CTU, the related command is ATEE. And the ENCRYPTION

KEY parameter is set with set Link Key function. In this case, the X-CTU command is ATKY.

 All Waspmotes’ XBees are set in mode AP = 2 (API mode). 