Steps in installing X-CTU software:
1. Getting X-CTU :
X-CTU was developed by Digi and it is only available for Windows
2 . Installing X-CTU :
Once X-CTU has been downloaded
The next step is installing the program.
3 .Configuring X-CTU :
When X-CTU has been properly installed, the Wasp mote Gateway can be connected to the
computer.
It will be recognized as a ‘USB Serial Port’
7/28/2019 X CTU Installation
http://slidepdf.com/reader/full/x-ctu-installation 3/16
Finally, we launch X-CTU and the program will start.
A window like the one below will appear, showing the different functions and the
different COM detected.
7/28/2019 X CTU Installation
http://slidepdf.com/reader/full/x-ctu-installation 4/16
If Wasp mote Gateway COM does not appear automatically, we must add it
manually.
To add a COM port we have to stay in ‘PC Settings’ tab, and change to ‘User Com
Ports’ tab.
There is a little box to add Com Ports, so we will add the port as is shown below
7/28/2019 X CTU Installation
http://slidepdf.com/reader/full/x-ctu-installation 5/16
4 . Details for the X-CTU operation:
4.1 – Place the XBee you need to configure in the Gateway. Then connect the
Gateway to a USB port in your PC
4.2 – Open the X-CTU application, select the appropriate communication port and
configure it as shown in next slide
7/28/2019 X CTU Installation
http://slidepdf.com/reader/full/x-ctu-installation 6/16
7/28/2019 X CTU Installation
http://slidepdf.com/reader/full/x-ctu-installation 7/16
4.3 – Perform the test (there is a button for that) and check the application delivers a
message similar to this one
It is possible that X-CTU asks you to do a reset of the XBee in this step (or in the nextsteps). To do that, just press the button “RST” in your Gateway for 1 or 2 seconds
7/28/2019 X CTU Installation
http://slidepdf.com/reader/full/x-ctu-installation 8/16
4.4 – Then go to the Modem Configuration tab, and select the ‘Read’ option.
We must check each parameter first
7/28/2019 X CTU Installation
http://slidepdf.com/reader/full/x-ctu-installation 9/16
4.5 – Check the first parameter, CH
7/28/2019 X CTU Installation
http://slidepdf.com/reader/full/x-ctu-installation 10/16
4.6 – The PAN ID
7/28/2019 X CTU Installation
http://slidepdf.com/reader/full/x-ctu-installation 11/16
4.7 – The destination address (2 parts)
7/28/2019 X CTU Installation
http://slidepdf.com/reader/full/x-ctu-installation 12/16
4.8 – The KY parameter (if needed). It must be set as hexadecimal key
7/28/2019 X CTU Installation
http://slidepdf.com/reader/full/x-ctu-installation 13/16
4.9 – The serial interface baud rate
7/28/2019 X CTU Installation
http://slidepdf.com/reader/full/x-ctu-installation 14/16
4.10 – The API options
7/28/2019 X CTU Installation
http://slidepdf.com/reader/full/x-ctu-installation 15/16
5 – If you have networking problems, please check these tips:
All XBees are in the same network that the Gateway (or Meshlium). In Waspmote’s API, PAN
ID parameter is set with setPAN function. You can also set this parameter for each XBee
plugging it to the Gateway, and then connecting it to a PC: the Digi’s X-CTU application helps to
check and set the XBee’s configuration. In this case, you must use the ATID command.
All XBees are in the same channel. The CHANNEL parameter is set with set Channel function.
If you want to do it in the X-CTU way, you must use the ATCH command.
All Waspmotes are transmitting towards the MAC of the Gateway (or Meshlium).
All XBees are configured to 115200 bps (in Waspmote PRO). In X-CTU, you can control data
baud rates executing the ATBD command.
All XBees have the same encryption options. The ENCRYPTION MODE parameter is set withset Encryption Mode function. In X-CTU, the related command is ATEE. And the ENCRYPTION
KEY parameter is set with set Link Key function. In this case, the X-CTU command is ATKY.
All Waspmotes’ XBees are set in mode AP = 2 (API mode).
7/28/2019 X CTU Installation