47
Ron Six, Instructor Senior Utility Consultant AEGIS Insurance Services, Inc. 201/417-2487 [email protected] WRGC Pinpointing Underground Gas Leaks

WRGC Pinpointing Underground Gas Leaks

  • Upload
    ely

  • View
    34

  • Download
    0

Embed Size (px)

DESCRIPTION

WRGC Pinpointing Underground Gas Leaks. Ron Six, Instructor Senior Utility Consultant AEGIS Insurance Services, Inc. 201/417-2487 [email protected]. A E G I S. A ssociated E lectric G as I nsurance S ervices. AEGIS Background Information. - PowerPoint PPT Presentation

Citation preview

Page 1: WRGC Pinpointing Underground              Gas Leaks

Ron Six, Instructor Senior Utility Consultant AEGIS Insurance Services, Inc.

201/417-2487

[email protected]

WRGC Pinpointing Underground Gas Leaks

Page 2: WRGC Pinpointing Underground              Gas Leaks

A E G I SA E G I SAAssociated EElectric GGas IInsurance SServices

Page 3: WRGC Pinpointing Underground              Gas Leaks

• Utility Mutual Insurance Company(member owned)

• Formed in 1975 by 22 gas utilities

• Electric Utilities began joining in 1977

• 375 members – 95% utilities and related energy

AEGISAEGISBackground InformationBackground Information

Page 4: WRGC Pinpointing Underground              Gas Leaks

Our main job is not finding & fixing leaks

Our main job ispublic safety

Page 5: WRGC Pinpointing Underground              Gas Leaks

Is not an exact science.It is a developed skill which is learned and perfected through your mistakes and your successes.

Pinpointing

Page 6: WRGC Pinpointing Underground              Gas Leaks

Major Causes of Leaks

• Corrosion

• Mechanical failure

• Improper installation

• Improper design

• Faulty materials

• 3rd Party Damage - “Dig-Ins”

Page 7: WRGC Pinpointing Underground              Gas Leaks

#682 #686

Dead Cast Iron Gas Main

Water Main

4” Plastic Main 45 PSI4” Plastic Main 45 PSI

ASH STASH ST

Page 8: WRGC Pinpointing Underground              Gas Leaks

The “Find and Fix Syndrome”

The cure for this is to ask yourself a question “Where is the gas”? If you can answer the question that the gas is not affecting people and it is not affecting property you are cured. You must ask yourself this question on every leak before you get into the “repair” mode.

Page 9: WRGC Pinpointing Underground              Gas Leaks

Our main job is not finding & fixing leaks

Our main job ispublic safety

Page 10: WRGC Pinpointing Underground              Gas Leaks

Detect

Pinpoint

Repair

Page 11: WRGC Pinpointing Underground              Gas Leaks

w

h

e

r

e

is the

gas?

Evaluating The Leak

Where is the gas?

Page 12: WRGC Pinpointing Underground              Gas Leaks

Evaluating The Leak

here is the gas?• W• H• E• R• E

ow much is there?xtent of hazard (migration)elation to other structuresvaluate/evacuate

Page 13: WRGC Pinpointing Underground              Gas Leaks

Factors Affecting Gas Migration

• Soil type

• Soil moisture

• Surface cover

• Line pressure

• Depth of burial

• Leak size and age

• Change in elevation=slope

• Path of least resistance

Page 14: WRGC Pinpointing Underground              Gas Leaks

• Centering = Where is the gas?

• Pinpointing = Where is the leak?

• The leak must be centered before it is pinpointed

Page 15: WRGC Pinpointing Underground              Gas Leaks

Be Careful – “Don’t make a leak, looking for a leak.”

Centering The Leak

• Probe holes must be of sufficient depth

• Test all available openings

• “Zero out” N-S-E-W

• You must have sufficient information to make a good judgement

Page 16: WRGC Pinpointing Underground              Gas Leaks

Recent Natural Gas Incidents Springfield, MA

Page 17: WRGC Pinpointing Underground              Gas Leaks

Methods Of Locating The Line

• Maps

• Records

• System experience

• Electronic locators1. Basic principles of operation2. Inductive vs. Conductive3. Overcoming problems

Page 18: WRGC Pinpointing Underground              Gas Leaks

Consistency = Success

• Exact location of main, services etc.

• Size of test hole (aeration is the key)

• Depth of test hole (must be consistent)

• Location of test holes (same side of main)

• Instrument use (consistency in testing)

Page 19: WRGC Pinpointing Underground              Gas Leaks

PLACEMENT OF DRILL HOLES

• Where and how many?

• What size test holes?

• How deep?

• How far apart?

19

Page 20: WRGC Pinpointing Underground              Gas Leaks

Size of the Test Hole

½” Test Hole 1” Test Hole

Page 21: WRGC Pinpointing Underground              Gas Leaks

Size of the Test Hole

½” Test Hole 1” Test Hole

4x’s the Aeration4x’s the AerationFrom the 1” Test Hole vs. From the 1” Test Hole vs.

the ½” Test Holethe ½” Test Hole

Page 22: WRGC Pinpointing Underground              Gas Leaks

The Size of the test hole is critical

Pinpointing with a ½” test hole Pinpointing using a 1” test hole

22

Page 23: WRGC Pinpointing Underground              Gas Leaks

Minnich Hornet Drill

Page 24: WRGC Pinpointing Underground              Gas Leaks

SAVE

ANOTHER

MISSED

EXCAVATION

Page 25: WRGC Pinpointing Underground              Gas Leaks

30% Gas @ Foundation Wall

90% Gas @ Curb

Concrete Sidewalk

4” Bare Steel 4” Bare Steel 45 PSI45 PSI

OLD MAIN STREETOLD MAIN STREET

#400#402#404

Page 26: WRGC Pinpointing Underground              Gas Leaks

Use Of Soil Purger (cont’d)

• The soil purger is your best friend or worst enemy, depending on where and how it is used

Page 27: WRGC Pinpointing Underground              Gas Leaks

Types of Soil Purgers

Page 28: WRGC Pinpointing Underground              Gas Leaks
Page 29: WRGC Pinpointing Underground              Gas Leaks

30% Gas @ Foundation Wall

90% Gas @ Curb

Concrete Sidewalk

8” CI UP8” CI UP

OLD MAIN STREETOLD MAIN STREET

#400#402#404 Never purge Never purge near foundationnear foundation

Never purge Never purge near foundationnear foundation

Purge Away From Purge Away From FoundationFoundationThis will draw the gas away from This will draw the gas away from the building and block the gas from the building and block the gas from migrating to the foundation wallmigrating to the foundation wall

Purge Away From Purge Away From FoundationFoundationThis will draw the gas away from This will draw the gas away from the building and block the gas from the building and block the gas from migrating to the foundation wallmigrating to the foundation wall

Page 30: WRGC Pinpointing Underground              Gas Leaks

Grade 1 Leak Repairs (Did you find “a” leak or did you find “the” leak?)

• You must not leave a Grade 1 Leak indication as long as the conditions that got you there are still present. If the readings went from 30% gas to 3% gas at the foundation it is still a technical Grade 1 leak. Purge the soil, get the readings to 0%, wait and make sure that the readings do not return.

Page 31: WRGC Pinpointing Underground              Gas Leaks

60% Gas

15% Gas

8” Steel UP CWP

Maple Street

Curb

Page 32: WRGC Pinpointing Underground              Gas Leaks

8” Steel UP CWP

Curb

Service Line

70%

50%

75%

8-10’ 8-10’

Maple Street

60% Gas

15% Gas

Page 33: WRGC Pinpointing Underground              Gas Leaks

8” Steel UP CWP

Service Line

40%

35%

45%

0%15%

50%50%50%45%10%0%

Maple Street

60% Gas

15% Gas

Curb

Slope

Page 34: WRGC Pinpointing Underground              Gas Leaks

Using The Soil Purger In The Pinpointing Process

• Purge from a hole where you know that the leak is not

• Plug holes near purge point

• Dense soil or moisture – time the purge/purge each hole

• Use it only when all other methods have failed

Page 35: WRGC Pinpointing Underground              Gas Leaks

Test Methods

• Combustible gas indicator1. Top & bottom of hole2. Time the readings

• Natural ventilation1. Wait…let holes vent

• Blow pipe – vapors/soap top of hole

• Odor

Page 36: WRGC Pinpointing Underground              Gas Leaks

Use Of Soil Purger

• Should not be used on every leak

• Operation:1. In the pinpoint process2. As a safety tool –

Never use near foundation of building3. Residual gas

• Choosing a purge point is the key

• Techniques

Page 37: WRGC Pinpointing Underground              Gas Leaks

10% Gas In Sewer Manhole

6” Steel UP6” Steel UP

ASH STREETASH STREET

CURB LINE

Page 38: WRGC Pinpointing Underground              Gas Leaks

Manhole

CGI Test

CGI Test

Gas Readings In Manhole

• Is gas in the sewer or just using the manhole as a venting point?

• Test top and bottom

• Percent gas readings will generally not be sewer gas

Page 39: WRGC Pinpointing Underground              Gas Leaks

Using Test ResultsUsing Test Results Using System DesignUsing System Design

Using Your ExperienceUsing Your Experience

“Make Your Mark”

Remember:Remember: It is much cheaper to drill than to dig.It is much cheaper to drill than to dig.

Do you have Do you have enoughenough holes to give holes to give you you enough information about the enough information about the leak?leak?

Page 40: WRGC Pinpointing Underground              Gas Leaks

The Dry Hole

• Probe along the pipe

• Expose all of the pipe, not just the top

• Learn from your mistakes

• Use the hole to your advantage…no one “hits” them all

• Is it our gas?

Page 41: WRGC Pinpointing Underground              Gas Leaks

High SchoolHigh School

6565 6969 7171

K-StreetK-Street

6” Low Pressure Cast Iron6” Low Pressure Cast Iron

4” High Pressure Steel4” High Pressure Steel

6767

25% gas in sewer manhole25% gas in sewer manhole

15% gas @ curb15% gas @ curb

Page 42: WRGC Pinpointing Underground              Gas Leaks

Checking After The Repair

• Did we find “the” leak?

• Residual gas – when will it go away?

• Cleanup/plugging the test holes

• Importance of proper documentation

Page 43: WRGC Pinpointing Underground              Gas Leaks

Stray Gas

• Is it lighter or heavier than air?

• Is there ethane in the sample?

• Is it a hazard?

• What is sewer gas/decomposition gas?

• Natural gas vs. stray gas

• Use of charcoal filter

• Use of collection bottles/bags

• Responsibilities regarding stray gas

• “Reasonable person concept”

Page 44: WRGC Pinpointing Underground              Gas Leaks

Ethane

No Ethane

Natural GasNatural GasNatural GasNatural Gas

Sewer GasSewer GasSewer GasSewer Gas

MethaneNitrogen

CO2

Chromatographic AnalysisComparison

Page 45: WRGC Pinpointing Underground              Gas Leaks

Remember:The Job Is Not Completed

• Until all paperwork/documentation is completed:

– Neatly– Thoroughly– Accurately

• You may do everything right, but you may be judged by what is or is not documented

Page 46: WRGC Pinpointing Underground              Gas Leaks

Be Alert

Be Prepared

Be Safe

Page 47: WRGC Pinpointing Underground              Gas Leaks

AEGIS Insurance Services, Inc.AEGIS Insurance Services, Inc.Thank You

Please visit our website @www.aegislink.com