5
Water meters Mechanical water meters Totalling Flow and Level GC-01-001 page 724 20080301 Index and product compare page 725 page 726 page 727 Cold water meter Wet dial register 0.0225 - 30 m³/hour Cold water meter Dry dial register 0.0225 - 20 m³/hour Cold water meter 1-1000 m³/hour A"-1 A" (BSP male thread) DN 50 (PN 16 DIN flanges) Brass construction Max. 16 bar Max. 40 °C Precision 2% Wet dial register KIWA approved Version with pulse transmitter A" -1A" BSP male thread Brass construction Max. 16 bar Max. 50 °C Precision 2% Dry dial register KIWA approved (DN 15/20) Horizontal or vertical installation Prepared for pulse transmitter DIN PN 16 flanges Cast iron, epoxy coated Max. 16 bar Max. 50 °C Dry dial register Precision ± 2% KIWA approved (optional) Horizontal and vertical installation Prepared for pulse transmitter (for retrofitting) page 728 Hot water meter 0.03 - 30 m³/hour A"-1 A" (BSP male thread) DN 50 (PN 16 DIN flanges) Brass construction Max. 16 bar Max. 120 °C Precision 2% Dry dial register Horizontal installation Fitted with pulse transmitter

Water meters Mechanical water meters Totalling - gca.pdf · Water meters Mechanical water meters ... • BSP male thread • Brass construction • Max. 16 bar ... 50 DN 50 166 78

  • Upload
    lamanh

  • View
    216

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Water meters Mechanical water meters Totalling - gca.pdf · Water meters Mechanical water meters ... • BSP male thread • Brass construction • Max. 16 bar ... 50 DN 50 166 78

Water metersMechanical water metersTotalling

Flow and Level GC-01-001 page 724

2008

0301

Index and

pro

duct co

mp

are

page 725 page 726 page 727

Cold water meterWet dial register0.0225 - 30 m³/hour

Cold water meterDry dial register0.0225 - 20 m³/hour

Cold water meter1-1000 m³/hour

• A"-1 A" (BSP male thread)• DN 50 (PN 16 DIN flanges)• Brass construction• Max. 16 bar• Max. 40 °C• Precision 2%• Wet dial register• KIWA approved• Version with pulse transmitter

• A" -1A"• BSP male thread• Brass construction• Max. 16 bar• Max. 50 °C• Precision 2%• Dry dial register• KIWA approved (DN 15/20)• Horizontal or vertical

installation• Prepared for pulse transmitter

• DIN PN 16 flanges• Cast iron, epoxy coated• Max. 16 bar• Max. 50 °C• Dry dial register• Precision ± 2%• KIWA approved (optional)• Horizontal and vertical

installation• Prepared for pulse transmitter

(for retrofitting)

page 728

Hot water meter0.03 - 30 m³/hour• A"-1 A" (BSP male thread)• DN 50 (PN 16 DIN flanges)• Brass construction• Max. 16 bar• Max. 120 °C• Precision 2%• Dry dial register• Horizontal installation• Fitted with pulse transmitter

Page 2: Water meters Mechanical water meters Totalling - gca.pdf · Water meters Mechanical water meters ... • BSP male thread • Brass construction • Max. 16 bar ... 50 DN 50 166 78

Water metersMechanical water metersTotalling

Flow and Level GC-01-002 page 725

2008

0301

Cold water meterWet dial register0.0225 - 30 m³/hour• fig. 8210• fig. 8211

• A"-1 A" (BSP male thread)• DN 50 (PN 16 DIN flanges)• Brass construction• Max. 16 bar• Max. 40 °C• Precision 2%• Wet dial register• KIWA approved• Version with pulse transmitter

Mechanical water meters for measuring clean water up to 50 °C maximum. The metershave a precision of 2% and are KIWA approved. Installation both horizontally andvertically for version without pulse transmitter. Many possibilities, including versionwith pulse transmitter mounted (limited to horizontal mounting straightup).

MaterialsBody: BrassRegister unit: Plastic with metal partsFigure 8210: Drum register without pulse transmitterFigure 8211: Drum register with reed contact pulse transmitter

(specify pulse value when ordering)

Ordering informationOrdering code Bore Continuous load Range Pulse value

Qn [m3/h][mm] [m3/h] [litre/pulse]

8210 15 1.5 0.0225- 3 None8210 20 2.5 0.0375- 5 None8210 25 3.5 0.0525- 7 None8210 32 6 0.090 -12 None8210 40 10 0.150 -20 None8210 50 15 0.3 -30 None8211 15 1.5 0.0225- 3 1, 10, 100 or 10008211 20 2.5 0.0375- 5 1, 10, 100 or 10008211 25 3.5 0.0525- 7 1, 10, 100 or 10008211 32 6 0.090 -12 1, 10, 100 or 10008211 40 10 0.150 - 20 1, 10, 100 or 10008211 50 15 0.3 - 30 1, 10, 100 or 1000Please note: Pulse transmitter/-value not possible to retrofit or change.Watermeters are standard supplied without pipe connectors.Pipe connectors (figure 8209) available on request.

Building-in possibilities

Not allowed

Version with pulse transmitter limited to horizontal mounting straightup.

DimensionsBore Connection B H1 H2 L1 Weight[mm] [mm] [kg]15 C" 100 31 115 165 1.520 1 " 100 31 115 190 1.625 1B" 100 31 115 260 2.232 1A" 100 43 130 260 2.540 2 " 100 46 153 300 3.750 DN 50 135 83 189 270 10

B

L1

H1D

H2

B

H2

H1

Flange connection

Threaded connection

L1

Page 3: Water meters Mechanical water meters Totalling - gca.pdf · Water meters Mechanical water meters ... • BSP male thread • Brass construction • Max. 16 bar ... 50 DN 50 166 78

Water metersMechanical water metersTotalling

Flow and Level GC-01-003 page 726

2008

0301

Cold water meterDry dial register0.0225 - 20 m³/hour• fig. 8214

• A" -1A"• BSP male thread• Brass construction• Max. 16 bar• Max. 50 °C• Precision 2%• Dry dial register• KIWA approved (DN 15/20)• Horizontal or vertical

installation• Prepared for pulse transmitter

Mechanical water meters for measuring potable water up to maximum 50 °C.These meters are so-called volumetric meters, so that a very reliable precision can beguaranteed.The meters are standard prepared for an impulse unit (reed contact), that can easily beretrofitted when required.

MaterialsBody: BrassInternal parts: Plastic with metal partsThe register is hermetically sealed and filled with a non-toxic lubricating fluid. Adiaphragm ensures that the pressure of this fluid is always equal to that of the water.

OptionsA" – C" 1" - 1A" Retrofit afterwards

Reed contact pulse transmitter 0.5 ltr/pulse 5 ltr/pulse Yes

Contact rating 35V at 3-35 mA, depending on the application

Ordering informationOrdering code Bore Continuous load Range Pulse transmitter

Qn [m3/h][mm] [m3/h]

8214 15 1.5 0.0225 - 3 Optional8214 20 2.5 0.0375 - 5 Optional8214 25 3.5 0.0525 - 7 Optional8214 32 6 0.090 - 12 Optional8214 40 10 0.150 - 20 OptionalWatermeters are standard supplied without pipe connectors.Pipe connectors (figure 8209) available on request.

The piston is equipped with grooves in order to achieve an optimum measurement result.

DimensionsBore Connection L1 L2 D1 D2 D3 Weight[mm] [mm] ["] [mm] [kg]15 C" 165 40 C" A 86 1.120 1 " 190 50 G1 C 86 1.325 1B" 260 60 G1 B 1 104 2.932 1A" 260 60 G1 A 1B 120 3.640 2 " 300 70 G2 1A 158 6

D1

D3

L2

D2

L1

Page 4: Water meters Mechanical water meters Totalling - gca.pdf · Water meters Mechanical water meters ... • BSP male thread • Brass construction • Max. 16 bar ... 50 DN 50 166 78

Water metersMechanical water metersTotalling

Flow and Level GC-01-004 page 727

2008

0301

Cold water meter1-1000 m³/hour• fig. 8215

• DIN PN 16 flanges• Cast iron, epoxy coated• Max. 16 bar• Max. 50 °C• Dry dial register• Precision ± 2%• KIWA approved (optional)• Horizontal and vertical

installation• Prepared for pulse transmitter

(for retrofitting)

Water meters suitable for measuring large quantities of potable water. Suitable forwater with a temperature of maximum 50 °C. These meters can be installed eitherhorizontally or vertically.

MaterialsMaterial of case: Cast iron, epoxy coatedMaterial of register unit: Plastic with metal parts

OptionsDN 50…DN125 DN 150…DN200 Retrofit

afterwardsReed contact pulse transmitter 100 or 1000 ltr/pulse 1000 or 10000 ltr/pulse YesSpecial 10 ltr/pulse NoOpto-electr. pulse transmitter 1 ltr/pulse 10 ltr/pulse NoInductive pulse transmitter 1 ltr/pulse 10 ltr/pulse No

Ordering informationOrdering code Bore Continuous load Range Pulse transmitter

Qn [m3/h][mm] [m3/h]

8215 DN 50 15 1 -90 Optional8215 DN 65 25 1.5 - 120 Optional8215 DN 80 40 2 - 200 Optional8215 DN 100 60 2 - 250 Optional8215 DN 125 100 2 - 250 Optional8215 DN 150 150 2 - 600 Optional8215 DN 200 250 6 - 1000 Optional

Not allowed

DimensionsBore Connection B H1 H2 H3 L Weight[mm] [mm] [kg]

50 DN 50 166 78 207 254 200 1565 DN 65 186 86 215 254 200 1780 DN 80 200 94 234 265 225 19

100 DN 100 228 106 246 265 250 23125 DN 125 250 118 258 265 250 30150 DN 150 286 135 335 470 300 40200 DN 200 341 165 387 470 350 50

B

L

H1 D

NH2

H3

Page 5: Water meters Mechanical water meters Totalling - gca.pdf · Water meters Mechanical water meters ... • BSP male thread • Brass construction • Max. 16 bar ... 50 DN 50 166 78

Water metersMechanical water metersTotalling

Flow and Level GC-01-005 page 728

2008

0301

Hot water meter0.03 - 30 m³/hour• fig. 8213

• A"-1 A" (BSP male thread)• DN 50 (PN 16 DIN flanges)• Brass construction• Max. 16 bar• Max. 120 °C• Precision 2%• Dry dial register• Horizontal installation• Fitted with pulse transmitter

Water meters suitable for measuring hot water up to maximum 120 °C. These metershave a precision of 2%. Only horizontal installation. These meters are fitted standardwith a pulse transmitter (reed contact) and metal cap to protect it from magneticinfluences.

Read-outRegister unit, visible through opening in metal hood

Output• Standard value: 1 pulse = 10 litre• Optional: 1 pulse = 1 litre

MaterialsBody: BrassRegister unit: Plastic with metal partsCable: Shielded pair

Ordering informationOrdering code Bore Continuous load Range Pulse value

Qn [m3/h][mm] [m3/h] [litre/pulse]

8213 15 1.5 0.030 - 3 1 or 108213 20 2.5 0.050 - 5 1 or 108213 25 3.5 0.065 - 7 1 or 108213 32 6 0.090 - 12 1 or 108213 40 10 0.160 - 20 1 or 108213 50 15 0.200 - 30 1 or 10Please note: Pulse value not possible change afterwards.Watermeters are standard supplied without pipe connectors.Pipe connectors (figure 8209) available on request.

DimensionsBore Connection B H1 H2 L1 Weight[mm] [mm] [kg]15 C" 96 40 175 165 220 1 " 96 40 175 190 225 1B" 102 45 185 260 2.832 1A" 102 45 185 260 2.840 2 " 136 50 102 300 550 DN 50 166 83 255 270 12.5

L1

H1

B

H2

L1

D1

B

H2

H1

Threaded connection

Flange connection