96
LIGHTING THE WORLD FOR OVER 25 YEARS WHOLESALER CATALOGUE THE EMERGENCY LIGHTING SPECIALISTS

Ventilux Buyers Guide

Embed Size (px)

Citation preview

Page 1: Ventilux Buyers Guide

LIGHTING THE WORLD FOR OVER 25 YEARS

WH

OLE

SA

LER

CA

TALO

GU

E

T H E E M E R G E N C Y L I G H T I N G S P E C I A L I S T S

Page 2: Ventilux Buyers Guide

Ventilux designs, manufactures and offers an extensive range of safety system products and services, including Emergency Lighting, Central Battery Systems, Luminaire Conversion Equipment, Nurse Call, Emergency Lighting Commissioning, Service and Maintenance.

Ventilux was founded in 1985, and has since grown steadily to become one of the largest Independent EmergencyLighting Manufacturers in Europe & the Middle East.

The Head Office at Dun Laoghaire, South Dublin, Ireland, is the centre of the Ventilux operation, with over 15,000 sq.ft. of state-of-the-art production facilities, research and development laboratories, in house training centre and global distribution warehouse.

Liverpool is the UK base for distribution, sales order processing and in-house conversions.

Ventilux operate, and are certified to, ISO:9001:2008.

EMERGENCY LIGHTING CENTRAL BATTERY SYSTEMS

LUMINAIRE CONVERS ION EQUIPMENT

NURSE CALL

EMERGENCY LIGHTING COMMISSIONING

SERVICE AND MAINTENANCE

T H E E M E R G E N C Y L I G H T I N G S P E C I A L I S T S

BESPOKE PRODUCT

Page 3: Ventilux Buyers Guide

V E N T I L U X - Quality Service

3

SYSTEM DESIGN SERVICEA team of qualified system engineers are permanently on hand at our design centres in Dublin and Liverpool, ready to help inevery aspect of system design. Using the latest computer aided techniques, qualified staff are able to prepare schemes and providequotations quickly and efficiently.

QUALITYAll Products bearing the Ventilux logo are CE marked, EMC compliant and manufactured and tested to the highest standards. Soconfident are we of our quality systems and testing procedures, we offer a 3 year warranty as standard on the majority of Ventiluxmanufactured products.

MANUFACTURE & DESIGNNew product development coupled with continuous refinement of existing product design have been essential elements of thecompany’s success. Modern manufacturing technology combined with stringent quality control ensures that Ventilux productsprovide the customer with top quality and excellent value for money. All products are manufactured to the appropriate EuropeanStandards and each unit is fully tested and inspected prior to dispatch.

CONVERSIONSVentilux offer a complete conversion service at our sites in Dublin & Liverpool, where the converted luminaires are CE markedand undergo full thermal and EMC testing.

DISTRIBUTIONVentilux products are readily available both in Ireland and the UK through a nationwide network of electrical wholesale distributors.To support our distributors, Ventilux keeps exceptionally high levels of finished stock at both Dublin and Liverpool, ready for immediate dispatch. Our Export department at Dublin provides worldwide support to a network of Distributors and Agents in all5 continents and are able to provide advice on domestic and international requirements.

Page 4: Ventilux Buyers Guide

Contents

4

Esca

pe R

oute

Lig

htin

gEx

it Si

gnag

e

OPTIC LED pg16OPTIC SURFACE pg17MOUNTED HALO LED pg18 EYECON LED pg19

SIRIUS LED pg20 SOLAS pg21 GALAXY RANGE pg22-23 NOVA SQUARE pg24

NOVA CIRCULAR pg25 WEATHERPROOF pg26 WEATHERLUX pg27 VISION pg28

TRIMLITE pg29 VERSE pg30 VANTAGE pg31 ECLIPSE RANGE pg32-33

EXLUX pg38 EXLUX PLUS pg39 VASARI pg40 GLADE pg41

STYLUX pg42 STYLUX RECESSED pg43 FOCAL pg44 ECLIPSE DUAL pg45

Econ

omy

Rang

e

ECONOMY BOX pg12 EXIT HORIZON pg12 VISOR pg13 EVOLUX pg13

SOLARIS pg14 ECONOMY TWINSPOT pg14 SOLARIS pg14 ECONOMY TWINSPOT pg14

Page 5: Ventilux Buyers Guide

Contents

5

SCOUT pg54 CORONA pg55 TWINLUX pg56-57 COMPACT TWIN LAMP pg58

Exit

Sign

age

Cont

inue

d.Tw

insp

ot &

Tun

gste

n Ha

loge

n Li

ghtin

g

VANGUARD pg46-47 VISTA SINGLE-SIDED pg48 VISTA DOUBLE-SIDED pg49 VISAGE pg50

EXLUX IP67 pg51

Emer

genc

y Co

nver

sion

Pow

er P

acks

INDEPENDENT LED pg60CONVERSION MODULE

MAINS LED pg61CONVERSION MODULE

CONVERTALUX pg62KPHFM SERIES

CONVERTALUX pg63KPT5 SERIES

CONVERTALUX pg65STARPACK

CONVERTALUX pg66TH PACK

CONVERTALUX QUICK pg67PACK & CEM SERIES

EMERGENCY LIGHTING SYSTEMS PG69-72� NETCOM 5XP PG70-71� STATIC INVERTER/CBS PG72� CENTRAL TEST UNITS PG72

DESIGNERS’ INFORMATION PG73-82SERVICE & MAINTENANCE PG83-85GLOSSARY PG86-87FIRE PROTECTION EQUIPMENT PG 95

LED MR16 pg64CONVERSION PACK

Page 6: Ventilux Buyers Guide

Some of our clients:DUBLIN AIRPORT (IRELAND)Not only is Dublin Airport Ireland’s busiest airport it is also amongst the ten busiest airports in Europe. Dublin Airport manages an average of 60,000 passengers per day, rising to 80,000 during the peak season.

Due to the size of the buildings Ventilux were asked to install our Netcom5XP addressable testing system.

Netcom 5XP (Page 70) can monitor over 25,000 luminaires from one central location (PC or Laptop). This installation resulted in considerable savings for Dublin Airport as it substantially reduced the labour costs associated with Emergency Lighting Testing.

AVIVA STADIUM (IRELAND)The Aviva Stadium is a sports stadium located in Dublin, Ireland, with a capacity for over 50,000 spectators. It is commonly known asLansdowne Road.

The original multi discipline ground was in existence at the Lansdowne Road site since 1872. In its old incarnation, prior to closure inDecember 2006, it was the oldest rugby union ground worldwide & the oldest sports stadium in Europe.

Due to the size of the site and also the numbers of spectators the venue would welcome on match day or for a concert, Ventilux StaticInverters were installed to reduce the power consumption costs associated with self contained fittings.

LIVERPOOL ONE DEVELOPMENT (ENGLAND)Liverpool One was a major new development in the heart of Liverpool city centre. It comprised of 30 major new buildings including 2department stores, banks, hotels, restaurants and luxury residential accommodation in 42 acres between Liverpool City Centre andthe Albert Dock.

The site required over 4,500 Ventilux Emergency Conversions Packs (Page 59)

In what is believed to be the largest emergency lighting installation in Europe with centralised monitoring and testing facilities, Ventiluxsupplied emergency luminaires, central battery systems and a central test and monitoring system.

COCA-COLA ENTERPRISES (ENGLAND)In Kent, England Coca-Cola Enterprises produce small plastic bottles, recyclable glass and cans across a variety of products includingSchweppes Cordial, Roses, 5 Alive, Ki-Ora and the Coke Contour bottle. Built in 1961, the plant now produces over 800 million drinksevery year.

As part of a major cost saving project, Ventilux managed the installation of a Static Inverter System to power over 500 LED luminaires including signage and open area luminaires.

Coca Cola chose over 500 ‘Halo LED’ luminaires to dramatically reduce the power consumption on site. The ‘HALO LED’ also gave ourclient 10 times the lamp life of their previous installation, resulting in huge immediate and long term cost savings.

INTERCONTINENTAL HOTEL DOHA (QATAR)The Intercontinental Hotel in Doha Qatar is a beautifully designed building incorporating nine floors, five of which house the 400 rooms.One of the floors has a choice of 3 restaurants and a buffet restaurant. The basement hosts a 150sqm Gymnasium, sauna, jacuzzi, andsteam room. Outside there is a swimming pool and a pool bar.

Ventilux Limited supplied our GLADE and FOCAL products on this project as the Hotel wanted a discrete yet stylish Emergency Lightinginstallation.

ABU DHABI NATIONAL OIL COMPANY (ABU DHABI)A.D.N.O.C. is the Abu Dhabi National Oil Company. The project consisted of supplying between 25 and 75 Petrol Stations throughoutAbu Dhabi over 3 years. All fittings were supplied the same throughout the installations to maintain a corporate image. Ventilux decided with the customer that the Weatherlux and the Stylux fittings were the most suitable. The Stylux Range was chosen forits durability and aesthetic appearance, whilst the Weatherlux was chosen for its vandal resistance and IP rating.

6

Page 7: Ventilux Buyers Guide

Made for you...

TAILOR-MADE PRODUCTS

VENTILUX have more than 25 years experience tailoring our products to the needs of our customers. From design tweaks andlogo additions, to the ground-up construction of a new product to meet a niche need, we can provide lighting solutions that suitsyour requirements perfectly.

We can modify our extensive range of existing products to better suit your needs, or work with you to custom-make lights to meetyour requirements. We’ve manufactured lights from standard finishes like brass and chrome to blue, green, red and even pink!for customers who require that personalised touch. Ventilux also offer a vast range of voltages for varying countries throughoutthe world.

So if you have a project that requires a unique product, or a certain colour talk to us!

DESIGN TEAM

VENTILUX prides itself on its flexible Engineering Design Department. This department consists of technical expert engineers allhighly trained graduates dedicated to developing cost effective Emergency Lighting designs.

Our design experts plan, budget and design for client specific requirements. Our design team utilise various state-of-the-art designsoftware packages to ensure quality and compliance in our Emergency Lighting designs.

Ventilux also has the ability to Project Manage small, medium and large projects from design phase, to commissioning and handover.We have specialist engineers to provide technical assistance at all times to ensure complete peace of mind.

7

Page 8: Ventilux Buyers Guide

Cost Saving FeaturesLED- LIGHT EMITTING DIODE

8

The operational life of the Ventilux LED'sused in our products is 50,000 hours.This equates to approximately five anda half years continuous operation. Thisis in stark contrast to the expected life ofa conventional 8 watt fluorescent lamp,which is approximately 5,000 hours.

With fluorescent lamps, the true cost ofthe lamp is the cost of replacement lampplus the labour expense and timeneeded to replace them - which can beconsiderable.

These costs are significant factors withever increasing operational costs, espe-cially where there are a large number ofinstalled luminaires.

Another key strength of the Ventilux LED range is the reduced power consumption of the LED emergency module. The LED modulecharges the Ni-Mh battery typically at 15- 25% power consumption compared to a conventional Ni-Cd charger.

300 SERIESA conventional 8 watt escape route luminaire will give approximately 80-90 lumens (light output) in Emergencycondition.

With Cree LED's, Ventilux can offer up to an impressive 300 lumens in Emergency! Therefore in certain appli-cations instead of installing 4 bulkheads for example, you would only need 1 of our 300 Series luminaires!

This provides our customers with fantastic initial and long term cost savings. As you can imagine, installing less fittings, replacingless batteries and extending lamp life will lead to significant savings.Just look for the 300 Series logo in our product guide for this cost saving feature.

KEEP IT GREENIn addition to the cost savings the Ventilux LED product range offers, the product range also offers the client anenvironmentally friendly emergency lighting solution.

Nickel-metal hydride (Ni-Mh) batteries are commonly considered to have lower environmental impact than con-ventional nickel cadmium (Ni-Cd) batteries, due to the absence of toxic cadmium, LED's have a further environ-mental advantage in that they contain no environmentally hazardous mercury, unlike fluorescent lamps.

300 SERIES

Page 9: Ventilux Buyers Guide

Cost Saving Features

9

VENTILUX AUTO-TEST MODULEThe Ventilux Auto-Test feature is a stand-alone integral testing solution for small tomedium size installations.

The Auto-Test module is able to perform a test sequence and report the health of thebattery, lamp or charger via a Tri-Colour LED.

Pre-programmed to the testing requirements of EN50172 the Auto-Test module offers acost competitive solution and peace of mind where automated testing is concerned.

*For a Ventilux Auto Test function please specify /AT

WHAT ARE THE FEATURES?• Maintained and non-maintained functionality selectable on the module.• Optional audible alarm if required.• Capable of tracking and storing day count.• Built-in pre-start sequence to ensure not all emergency luminaire test at the same time

ensuring that the emergency lighting installation will always have emergency light coverage.• Countdown feature via Tri-Colour LED to indicate when full duration test will occur.

• Optional Push Test function to perform functional test. *Please specify /PT

VENTILUX MICROWAVE SENSORThe Ventilux Microwave Sensor is ideally suited to commercial applications such as shops and offices, in areas where lighting can be left on. It is alsosuitable for store room, toilet applications or any other room where lighting may accidentally be left turned on.

The Ventilux Microwave Sensor uses ultra-high frequency radio waves known as microwaves, and the principle of the Doppler Effect to detect motion. The MicrowaveSensor will stay on as long as it detects movement within its range of sensitivity.

HOW DOES IT WORK?The Microwave Sensor sends out radio waves that bounce off nearbysurfaces and return to the sensor. Motion in the area changes the speedof the waves returning to the sensor. The sensor detects the change andinterprets it as occupancy. This causes the sensor to turn ON the lumi-naire.

High frequency radio waves can penetrate certain materials, therefore the microwave sensor can be installed behind a luminaire diffuser and therefore offer a big advantage over conventional PIR switcheswhich require a line of sight to function correctly.

WILL I SAVE MONEY?The energy savings will be extremely high with a very short payback with this small compact and easyto install module. With a range of up to 10 meters, multi units can be used in offices and corridors to reduce long term operational costs. Just imagine the high costs of leaving luminaires on 365 days a year, 24 hours a day. Why not integrate a Ventilux Movement Sensor and start saving money today!

*For a Ventilux Movement Sensor please specify /MWS

Page 10: Ventilux Buyers Guide

New ProductsEscape Route Lighting

10

OPTIC LED SURFACE MOUNTEDThe Optic Surface Mounted LED is specifically designed to complement the Optic LED range and offers a cohesiveescape route and open plan emergency lighting solution for applications where recessing into the ceiling is not anoption. Customers have found stair cores, in particular, an area where recessing is just not possible.

The OPTIC LED SURFACE MOUNTED version is a cost effective and environmentally friendly solution to this problem.(Page 17)

SCOUT LEDPurpose designed for interior use, the Scout LED luminaire houses a unique’ swivel and rotate system, which allowsindependent positioning of the projectors, giving the installer more flexibility on installation.

The 6 WATT CREE LED'S once again offer reduced power consumption compared to the standard 20 or 55wattTungsten Halogen lamp. (Page 54)

EYECON LEDThe Eyecon LED is a discrete and unobtrusive LED Escape Route and Open Plan Emergency Lighting solution. TheEyecon LED offers an even lower power consumption than a 3 Watt, consuming just 1 Watt.

Please refer to page 19 to see the savings this luminaire offers compared to a conventional 8 watt luminaire.

SIRIUS LEDBy functioning as both a mains and emergency LED driver, the Sirius LED luminaire provides an environmentally friendly, long life and economically viable alternative to a traditional fluorescent 16, 28 and 38watt luminaire.

In certain applications Ventilux can half our clients energy consumption by offering this easily to maintain LED luminaire. (Page 20)

For our EMERGENCY AND MAINS LED CONVERSION PACK for retro-fit refurbishment please refer to Page 67

INDEPENDENT LED CONVERSION MODULEThe exceptionally low profile 'Stand Alone' KPLED conversion kit can be fitted inside the latest generation slimlineluminaires and offers a cost effective solution to conventional linear fluorescent lamp conversions.

For more information on this and more innovative EMERGENCY CONVERSION TECHNOLOGY please refer toPage 59

Page 11: Ventilux Buyers Guide

11 Econ

omy

Rang

e

Page 12: Ventilux Buyers Guide

12

ECONOMY BOX EXITThe ECONOMY BOX EXIT sign luminaire is a cost effective,versatile and unobtrusive directional sign product. Designed tosatisfy statutory requirements for Exit Signs using panels selectedfrom our comprehensive range, which will correctly indicate thedirection of the escape route.

The housing provides down light through a carefully designedpanel in the lower surface of the luminaire to assist in the illu-mination of the emergency escape route.

• Dimensions: 420x200x65 (mm)• White finish as standard • 36 metre viewing distance • White powder coated galvanised steel housing Polycarbonate legend

Product Code Operation Lamp Battery Lumen IP Rating Weight

EBM3/F8 M T5-8 Watt 2.4V/4.5A/h 78 20 1.5kgEBM3/LED M LED 3.6V / 1.8A/h 70 20 1.5kg

HORIZON

• Dimensions: 400x250x30 (mm)• Chrome, Brass and White as standard• 36 metre viewing distance • Extruded aluminium body• Polycarbonate legend• 50,000hrs lamp life

Product Code Operation Lamp Battery Lumen IP Rating Weight

HZM3/LED M LED 3.6V/1.8A/h 70 20 2.5kg

Designed for indoor installation in a range of public locationsthe HHORIZON is an ideal cost effective solution where the em-phasis is on clear signage and aesthetic appearance.

Incorporating the latest LED technology, the HORIZON offers theclient long cost savings with respect to operational and mainte-nance costs.

Engineered with ease of installation and cost effectiveness as afocus, the HORIZON achives its goals while offering an excitingaesthetic to rival any edgelit sign luminaire on the market.

Please specify / Br (Brass) / CH (Chrome) / WH (White)

Page 13: Ventilux Buyers Guide

13

VISORDesigned for indoor and outdoor installation in a range ofcommercial and industrial locations, the compact VVisorLuminaire offers a high level of specification, ease of installationand excellent value for money.

Ease of installation, provided by a hinged mounted geartray anda choice of cable entries, as well as a lens design which maximiseslight distribution are key factors which make the Visor one of the mostexciting and popular luminaires available from Ventilux.

• Dimensions: 345x75x120 (mm)• White finish as standard• 22 metre viewing distance• Flame retardant ABS body• Polycarbonate diffuser• Exit Signage stickers also available• *Double-Sided Exit Signage available/DS

Product Code Operation Lamp Battery Lumen IP Rating Weight

VIM3/F8 M T5-8 Watt 2.4V/4.5A/h 78 65 1.5kgVINM3/F8 N-M T5-8 Watt 2.4V / 4.5A/h 87 65 1.2kgVIM3/LED M LED 3.6V / 1.8A/h 70 65 1.2kgVINM3/LED N-M LED 3.6V / 1.8A/h 70 65 0.9kg

EVOLUX

• Dimensions:• Lamp Head: 45mmx4mm• Charger Body: 165mmx31mm• Battery Body: 137mmx31mm• Chrome finish as standard• Other colours on request• 35mm Cut-out• 50,000hrs lamp life

Product Code Operation Lamp Battery Lumen IP Rating Weight

EVONM3/LED N-M LED 3.6V/2.1A/h 75 20 0.6 kg

Specifically designed with the most conventional architects andconsultants desires in mind, while maintaining the contractorsneeds as a priority during installation in prestigious areas.

Purpose designed for interior use, the EVOLUX luminaire is de-signed to fit into a hole of 35mm, and comes in two parts, givingthe installer more flexiibility and ease of installation.

Please see below*

IP65

O

Page 14: Ventilux Buyers Guide

14

SOLARISSSolaris-the elegantly slim range of emergency and match-ing mains luminaires from Ventilux is ideal for all prestigiouslocations, incorporating high efficiency 2D compact fluo-rescent lamps.

Identical housings are used for both emergency lighting andmains lighting versions allowing the same profile to be usedthroughout an installation.

• Dimensions: 330 dia x 115 (mm)• White finish as standard• Flame retardant ABS body• Opal Polycarbonate diffuser

Product Code Operation Lamp Battery Lumen IP Rating Weight

SRM3/F282D M 28 Watt 4.8V / 4.5A/h 191 65 3.1kgSRNM3/F282D N-M 28 Watt 4.8V / 4.5A/h 224 65 3.1kgSR/F282D/240 Mains 28 Watt N/A 2250 65 2.5kg

ECONOMY TWINSPOT

• Dimensions: 305x306x70 (mm)• White finish as standard• White powder coated steel housing (IP20 Version)• 50,000hrs- LED version• WETLED/NM3 300x290x68

Product Code Operation Lamp Battery Lumen IP Rating Weight

ETS20/NM3 N-M 2x20 Watt 2 x 12V/7.0A/h 600 20 8.3kgETSLED/NM3 N-M 2x4.8 Watt 2 x 6V/7.0A/h 240 20 4.3kg*WETLED/NM3 N-M 2x4.8 Watt 2 x 6V/7.0A/h 240 65 2.3kg

The Economy Twinspot range of luminaires have beenspecifically designed to provide a cost effective emergencylighting solution in high bay industrial areas, factories orlarge warehouses where there is a requirement to projecthigh intensity beams between the racks and equipment toilluminate walkways and assist safe evacuation in case ofemergency.

*WETLED/NM3

IP65

OIP65

O

Page 15: Ventilux Buyers Guide

Esca

pe R

oute

Lig

htin

g

15

Page 16: Ventilux Buyers Guide

Recessed

Optic LEDEscape Route

16

The Optic LED is specifically designed to offer a cohesive escape route and open plan emergency lighting solution within a specific project, maximisingemergency light distribution and offering long term costsavings to the client.

Available in a dedicated escape route and open planconfiguration the Optic LED is designed around themarket-leading American manufactured CREE LED.Configured in a 3 x 1 watt configuration, the Optic /Cree combination offers an impressive 300 lumens during emergency operation.

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify / 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time periode.g. / NM3 becomes / NM1 for 1 hours duration

• Lamp head dimensions: 140 x 32 D (mm)• Remote housing dimensions: 65mm x 700mm long• 50,000 hours lamp life• ABS Body complete with IP20 protection• White finish as standard. Other colours available on request• Also available with NETCOM 5XP or DALI (Page 70)• Available with Auto-Test function (Page 9)

Product Code Operation Lamp Battery Lumen VA Weight

OPM3/LED/ES M LED 4.8V / 4.5A/h 300 7 1.5kgOPM3/LED/OP M LED 4.8V / 4.5A/h 300 7 1.5kgOPNM3/LED/ES N-M LED 4.8V / 4.5A/h 300 3.5 1.5kgOPNM3/LED/OP N-M LED 4.8V / 4.5A/h 300 3.5 1.5kg

300 SERIES

Escape route/corridor application

Open plan application

Please specify / BL for Black

Page 17: Ventilux Buyers Guide

Optic LEDEscape Route

Surface Mounted

The Optic Surface Mounted LED is specifically designed to complement the Optic LED range and offera cohesive escape route and open plan emergencylighting solution.

The operational life of the high power CREE LED is50,000 hours. The long operational life of an LED lampis in stark contrast to the expected life of a conventional8 watt fluorescent lamp which is approximately 5000hours.

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify / 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: 200 L x 200 D x 70 H (mm)• 50,000 hours lamp life• Powder coated sheet steel housing • ABS lamp head complete with IP20 protection• White finish as standard. Other colours available on request• Also available with NETCOM 5XP or DALI (Page 70)• Available with Auto-Test function (Page 9)

Product Code Operation Lamp Battery Lumen VA Weight

OPM3/LED/ES/SM M LED 4.8V / 4.5A/h 300 8 1.7kgOPM3/LED/OP/SM M LED 4.8V / 4.5A/h 300 8 1.7kgOPNM3/LED/ES/SM N-M LED 4.8V / 4.5A/h 300 3.5 1.6kgOPNM3/LED/OP/SM N-M LED 4.8V / 4.5A/h 300 3.5 1.6kg

17

300 SERIES

Open plan application

Please specify / BL for Black

Escape route/corridor application

Page 18: Ventilux Buyers Guide

Halo LEDEscape Route

Purpose designed for interior use, the Halo 3 Wattluminaire is designed to fit into a hole of 38mm, andcomes in two parts, giving the installer more flexibilityand ease of installation.

Designed for indoor installation in a range of public locations the Halo 3 Watt is an ideal, cost effective solution, where the emphasis is on discrete and aesthetic appearance.

Product Code Operation Lamp Battery Lumen VA Weight

HANM3/LED/3W N-M LED 4.8V / 2.5A/h 180 2.1 1.0kgHAM3/LED/PLUS M LED 4.8V / 2.5A/h 180 5.0 1.5kg

18

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify / 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time periode.g. / NM3 becomes / NM1 for 1 hour duration

• Lamp head dimensions: 45 x 3 depth (mm)• Designed to fit into a 38mm diameter hole• Designed to fit into a 165mm ceiling void• White finish as standard • Other colours available on request• Also available with NETCOM 5XP (Page 70)• Available with Auto-Test (Page 9)

Recessed

/ PLUS for maintained operation

Page 19: Ventilux Buyers Guide

Eyecon LEDEscape Route

The Eyecon LED is specifically designed to offer a cohesive surface mounted escape route and open planemergency lighting solution within a specific project.

The Eyecon LED is designed around the market-leadingAmerican manufactured Cree LED. Configured in a single 1watt configuration, the Eyecon/Creecombination offers an impressive 120 lumens duringemergency operation.

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: 140 DIA x 48 H (mm)• 50,000 hours lamp life• ABS lamp head complete with IP20 protection • White finish as standard. Other colours available on request

Product Code Operation Lamp Battery Lumen VA Weight

EYNM3/LED N-M LED 4.8V / 1.3A/h 120 2.3 1.1kg

19

Surface Mounted

Emergency luminaire Power consumption Cost per unit of electricity Running cost per fitting (annually)NM 8 watt luminaire 5.5 watts €0.18 KWh €8.67 / £ 7.53 / $ 11.26 (US)EYECON 2.3 watts €0.18 KWh €3.62 / £ 3.14 / $ 4.70 (US)

Please specify /BL for Black

Page 20: Ventilux Buyers Guide

Sirius LEDEscape Route

20

By functioning as both a mains LED driver and emergency LED driver, the Sirius LED luminaire provides an environmentally friendly, long life and economically viable alternative to a traditional fluorescent luminaire.

Offering light output comparable to a conventional 28watt 2D fluorescent product, the Sirius LED offers theclient an easy opportunity to significantly reduce theircarbon footprints for a relatively low initial investmentand very quick payback time. The Sirius LED comescomplete with a 5 year warranty.

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify / 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time periode.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: 330mm DIA x 118 H (mm)• Flame retardant polycarbonate diffuser and base (IP 65)• Opal diffuser as standard. Prismatic diffuser available on request• White finish as standard, Please specify /CH (Chrome) /PB (Polished Brass) • Other colours available on request• Recessing Kit available on request• Also available with NETCOM 5XP (Page 70)• Available with Ventilux Movement Sensor (Page 9)• Available with Auto-Test/Push-Test function (Page 9)

Product Code Operation Lamp Battery Lumen VA Weight

SIM3/LED M LED 4.8V / 4.5A/h 300 16 1500gmsSINM3/LED N-M LED 4.8V / 4.5A/h 300 3 1500gms

*Please specify /240v after the above code for mains operation*Please specify /NL after the above code for integrated Nightlight

300 SERIES

IP65

OPlease specify /CH for Chrome

Page 21: Ventilux Buyers Guide

SolasEscape Route

Solas, the elegantly slim range of emergency andmatching mains luminaires from Ventilux is ideal for allprestigious locations, incorporating high efficiency 2Dcompact fluorescent lamps.

Comprising an opalescent polycarbonate diffuser,snapped to a polycarbonate base, Solas is an exceptionally low profile emergency lighting luminaire.This is made possible by using a combined high frequency mains ballast and emergency ballast whichwas pioneered by Ventilux.

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify 24 / 50 / 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: 360 DIA x 115 H (mm)• Flame retardant polycarbonate diffuser and base (IP 54)• Opal diffuser as standard• White finish as standard, Please specify /CH (Chrome) /PB (Polished Brass)• Other colours available on request• Recessing Kit available on request• Also available with NETCOM 5XP or DALI Addressable (Page 70)• Available with Ventilux Movement Sensor (Page 9)• Available with Auto-Test/Push-Test function (Page 9)* Denotes 1 year warranty

Product Code Operation Lamp Battery Lumen VA Weight

SOM3/F162D M 16W 2D 4.8V / 4.5A/h 114 33.5 1.65kgSONM3/F162D N-M 16W 2D 4.8V / 4.5A/h 134 7.6 1.6kgSOM3/F282D M 28W 2D 4.8V / 4.5A/h 191 39.7 1.65kgSONM3/F282D N-M 28W 2D 4.8V / 4.5A/h 224 7.6 1.6kgSOM3/F382D* M 38W 2D 6.0V / 4.0A/h 210 40.9 1.8kgSONM3/F382D N-M 38W 2D 6.0V / 4.0A/h 248 7.6 1.75kg

•Please specify /240V after the above code for mains operation•Please specify /LED after the above code for LED operation•Please specify /NL after the above code for integrated Nightlight

21

Page 22: Ventilux Buyers Guide

Galaxy SquareEscape Route

22

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify 24 / 50 / 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time periode.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: 300 x 300 x 83 (mm)• Flame retardant polycarbonate diffuser and base (IP 65)• White finish as standard. Other colours on request• Also available with NETCOM 5XP or DALI Addressable (Page 70) • Available with Auto-Test/Push-Test function (Page 9)• Denotes 1 year warranty

300

83

Square

The Galaxy range is a discreet, robust and stylish polycarbonate emergency and mains luminaire withsnap fit diffusers.

Complemented with a matching range of square units.Ideal for all projects where a high quality, low budgetluminaire is required. Ideal for office, hotel and outdoorenvironments.

Product Code Operation Lamp Battery Lumen VA Weight

GSM3/F162D M 16W 2D 4.8V / 4.5A/h 114 33.5 2.3kgGSNM3/F162D N-M 16W 2D 4.8V / 4.5A/h 134 8 2.0kgGSM3/F282D M 28W 2D 4.8V / 4.5A/h 191 39.7 2.4kgGSNM3/F282D N-M 28W 2D 4.8V / 4.5A/h 224 8 2.1kg*GSM3/F382D M 38W 2D 6.0V / 4.0A/h 210 40.9 2.4kgGSNM3/F382D N-M 38W 2D 6.0V / 4.0A/h 248 7.6 2.1kg

*Please specify /240V after the above code for mains operation*Please specify /LED after the above code for LED operation

IP65

O

mm

Page 23: Ventilux Buyers Guide

Galaxy CircularEscape Route

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify 24 / 50 / 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: 360 x 83 (mm)• Flame retardant polycarbonate diffuser and base (IP 65)• White finish as standard. Other colours on request • Also available with NETCOM 5XP or DALI Addressable (Page 70)• Available with Auto-Test/Push-Test function (Page 9)• Denotes 1 year warranty

23

IP 65

Product Code Operation Lamp Battery Lumen VA Weight

GCM3/F162D M 16W 2D 4.8V / 4.5A/h 114 33.5 2.3kgGCNM3/F162D N-M 16W 2D 4.8V / 4.5A/h 134 8 2.0kgGCM3/F282D M 28W 2D 4.8V / 4.5A/h 191 39.7 2.4kgGCNM3/F282D N-M 28W 2D 4.8V / 4.5A/h 224 8 2.1kg*GCM3/F382D M 38W 2D 6.0V / 4.0A/h 210 40.9 2.4kgGCNM3/F382D N-M 38W 2D 6.0V / 4.0A/h 248 7.6 2.1kg

*Please specify /240v after the above code for mains operation**Please specify /LED after the above code for LED operation

360

83

Circular

mm

mm

O

Page 24: Ventilux Buyers Guide

Nova SquareEscape Route

24

The Nova Square luminaire is a robust, versatile andunobtrusive circular cast aluminium exterior IP65 emergency luminaire bulkhead.

The Nova Square offers an impressive range of coloursand styles suitable for wall and ceiling mounted applications.

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify 24 / 50 / 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time periode.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: 350 x 350 x 158 (mm)• Flame retardant polycarbonate diffuser (IP 65)• Grey/Black finish as standard with opal diffuser• Other colours available on request• Also available in PLL/PLC lamp• Also available with NETCOM 5XP or DALI Addressable (Page 70)• Available with Ventilux Movement Sensor (Page 9)• Available with Auto Test/Push Test function (Page 9)

IP65

OProduct Code Operation Lamp Battery Lumen VA Weight

NSM3/F162D M 16W 2D 4.8V / 4.5A/h 114 33.5 3.9kgNSNM3/F162D N-M 16W 2D 4.8V / 4.5A/h 134 8 3.6kgNSM3/F282D M 28W 2D 4.8V / 4.5A/h 191 39.7 4.0kgNSNM3/F282D N-M 28W 2D 4.8V / 4.5A/h 224 8 3.7kgNSM3/F382D M 38W 2D 4.8V / 4.5A/h 210 43 4.2kgNSNM3/F382D N-M 38W 2D 4.8V / 4.5A/h 248 5.8 3.9kg

*Please specify /240V after the above code for mains operation*Please specify /LED after the above code for LED operation

VANDALPROOF

300 SERIES

Add /GU

Add /EY2

Add /EY1

Please specify /BL for black

Page 25: Ventilux Buyers Guide

Nova CircularEscape Route

The Nova Circular can be supplied with optional decorative guards or eyelids to create a versatile rangeof vandal resistant luminaires which are available innon-maintained and maintained emergency lightingversions for 16 watt, 28 Watt or 38 watt 2D lamps.

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify 24 / 50 / 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: 360 x 178 (mm) Depth• Flame retardant polycarbonate diffuser (IP 65)• Grey/Black finish as standard with opal diffuser• Other colours available on request• Also available with NETCOM 5XP or DALI Addressable (Page 70)• Available with Ventilux Movement Sensor (Page 9)• Available with Auto-Test/Push-Test function (Page 9)

25

VANDALPROOF

IP65

OProduct Code Operation Lamp Battery Lumen VA Weight

NCM3/F162D M 16W 2D 4.8V / 4.5A/h 114 33.5 3.9kgNCNM3/F162D N-M 16W 2D 4.8V / 4.5A/h 134 8 3.6kgNCM3/F282D M 28W 2D 4.8V / 4.5A/h 191 39.7 4.0kgNCNM3/F282D N-M 28W 2D 4.8V / 4.5A/h 224 8 3.7kgNCM3/F382D M 38W 2D 4.8V / 4.5A/h 210 43 4.2kgNCNM3/F382D N-M 38W 2D 4.8V / 4.5A/h 248 5.8 3.9kg

*Please specify /240v after the above code for mains operation*Please specify /LED after the above code for LED operation

300 SERIES

Add /GU

/BL for Black

Add /EY1

Page 26: Ventilux Buyers Guide

Product Code Operation Lamp Battery Lumen VA Weight

Escape RouteWPM3/F8 M T5-8 Watt 2.4V / 4.5A/h 78 20 1.6kgWPNM3/F8 N-M T5-8 Watt 2.4V / 4.5A/h 87 8 1.5kgWPS3/F8 Sustained T5-8 Watt 2.4V / 4.5A/h 87 20 1.6kgWPM3/LED/3W M LED-3 Watt 4.8V / 4.5A/h 270 12 1.6kgWPNM3/LED/3W N-M LED-3 Watt 4.8V / 4.5A/h 300 4 1.5kg

Exit SignageWPM3/F8/EXIT M T5-8 Watt 2.4V / 4.5A/h N/A 20 1.6kgWPNM3/F8/EXIT N-M T5-8 Watt 2.4V / 4.5A/h N/A 8 1.5kgWPM3/LED/EXIT M LED-1 Watt 4.8V / 1.3A/h N/A 4 1.6kgWPNM3/LED/EXIT N-M LED-1 Watt 4.8V / 1.3A/h N/A 2 1.5kg

*Please specify /240v after the above code for mains operation*Please specify /3C after the above code for 3 Cell High Output Battery

WeatherproofEscape Route

26

The robust and durable design of the (IP65) WP Bulkhead Luminaire makes it ideal for a range of exterior and selected interior locations. Operators ofleisure centres, car parks, sports facilities, factories andunderground walkways will benefit from its tough, tamper resistant construction and ease of installation.

The WP range includes a flame retardant ABS body andincludes an Opal diffuser as standard.

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify 24 / 50 / 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: 368 x 150 x 102 (mm)• White finish as standard. Other colours available on request• Prismatic or Screen Print diffuser also available• Recessing Kit available on request• Also available as Cold Room fitting please contact Ventilux• Sticker legends (Page 74)• Also available with NETCOM 5XP or DALI Addressable (Page 70)• Available with Auto-Test/Push-Test function (Page 9)

View From 22M

300 SERIES

IP65

O

Page 27: Ventilux Buyers Guide

WeatherluxEscape Route

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify 24 / 50 / 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: 390 x 112 x 92 (mm)• Die cast aluminium body (IP65) with Opal diffuser as standard.• White finish as standard. Other colours available on request• Recessing Kit available on request• Sticker legends (Page 74)• Also available with NETCOM 5XP (Page 70)• Available with Auto-Test/Push-Test function (Page 9)

27

VANDALPROOF

Product Code Operation Lamp Battery Lumen VA Weight

Escape RouteWLM3/F8 M T5-8 Watt 2.4V / 4.5A/h 78 20 2.0kgWLNM3/F8 N-M T5-8 Watt 2.4V / 4.5A/h 87 8 1.6kgWLS3/F8 Sustained T5-8 Watt 2.4V / 4.5A/h 87 20 2.1kgWLM3/LED/1W M LED-1 Watt 4.8V / 1.3A/h 120 5 2.0kgWLNM3/LED/1W N-M LED-1 Watt 4.8V / 1.3A/h 120 2.3 1.6kg

Exit SignageWLM3/F8/EXIT M T5-8 Watt 2.4V / 4.5A/h N/A 20 2.0kgWLNM3/F8/EXIT N-M T5-8 Watt 2.4V / 4.5A/h N/A 8 1.6kgWLM3/LED/EXIT M LED-1 Watt 4.8V / 1.3A/h N/A 4 2.0kgWLNM3/LED/EXIT N-M LED-1 Watt 4.8V / 1.3A/h N/A 2 1.6kg

*Please specify /240v after the above code for mains operation*Please specify /3C after the above code for 3 Cell High Output Battery

A wide range of design and performance features makethe Weatherlux Luminaire ideal for exterior and selected interior locations.

Its robust construction of a cast aluminium base andpolycarbonate diffuser make it ideal for use in schools,leisure and community centres and all industrial andpublic access areas either as an emergency or mainsluminaire.

IP65

OView From 22M

Page 28: Ventilux Buyers Guide

VisionEscape Route

28

Available to meet a range of emergency luminaire requirements or as a mains unit, the stylish Visionmeets the requirements of all relevant EU Directives andcan be supplied in a choice of colours or finishes withall European emergency signage.

Ease of installation, as well as a lens design which maximises light distribution are key factors which makethe Vision one of the most popular luminaires available from Ventilux.

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify 24 / 50 / 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time periode.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: 330 x 95 x 80 (mm)• White finish as standard. Other colours available on request• Prismatic diffuser as standard. Screen Print/Opal diffuser on request• Recessing Kit available on request• Sticker legends (Page 74)• Also available with NETCOM 5XP (Page 70)• Available with Auto-Test/Push-Test function (Page 9)

IP65

O

View From 14M

Product Code Operation Lamp Battery Lumen VA Weight

Escape RouteVSM3/F8 M T5-8 Watt 2.4V / 4.5A/h 78 20 1.5kgVSNM3/F8 N-M T5-8 Watt 2.4V / 4.5A/h 87 8 1.2kgVSM3/LED/1W M LED-1 Watt 4.8V / 1.3A/h 120 5 1.5kgVSNM3/LED/1W N-M LED-1 Watt 4.8V / 1.3A/h 120 2.3 1.2kg

Exit SignageVSM3/F8/EXIT M T5-8 Watt 2.4V / 4.5A/h N/A 20 1.5kgVSNM3/F8/EXIT N-M T5-8 Watt 2.4V / 4.5A/h N/A 8 1.2kgVSM3/LED/EXIT M LED-1 Watt 4.8V / 1.3A/h N/A 4 1.5kgVSNM3/LED/EXIT N-M LED-1 Watt 4.8V / 1.3A/h N/A 2 1.2kg

*Please specify /240v after the above code for mains operation*Please specify /3C after the above code for 3 Cell High Output Battery

Page 29: Ventilux Buyers Guide

TrimliteEscape Route

For the ultimate in unobtrusive emergency lighting, theflush mounted Trimlite is the epitome of discretion, offering both the specifier and installer a high quality,easy-to-install recessed luminaire.

The Trimlite (IP42) is ideal for a wide range of commercial and institutional locations including, for example; offices, hotels, entertainment centres andpublic buildings. Where appearance is of major importance the Trimlite can also be supplied with brassor chrome finish to reflect the style of prestigious locations.

Product Code Operation Lamp Battery Lumen VA Weight

Escape RouteRM3/F8 M T5-8 Watt 2.4V / 4.5A/h 78 20 2.2kgRNM3/F8 N-M T5-8 Watt 2.4V / 4.5A/h 87 8 1.9kgRS3/F8 Sustained T5-8 Watt 2.4V / 4.5A/h 87 20 2.2kgRM3/LED/3W M LED-3 Watt 4.8V / 4.5A/h 270 12 2.0kgRNM3/LED/3W N-M LED-3 Watt 4.8V / 4.5A/h 300 4 2.0kg

Exit SignageRM3/F8/EXIT M T5-8 Watt 2.4V / 4.5A/h N/A 20 2.2kgRNM3/F8/EXIT N-M T5-8 Watt 2.4V / 4.5A/h N/A 8 1.9kgRM3/LED/EXIT M LED-1 Watt 4.8V / 1.3A/h N/A 4 1.6kgRNM3/LED/EXIT N-M LED-1 Watt 4.8V / 1.3A/h N/A 2 1.6kg

*Please specify /240v after the above code for mains operation*Please specify /3C after the above code for 3 Cell High Output Battery

29

View From 30M

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify 24 / 50 / 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: 385 x 170 x 7 (mm)• White powder-coated galvanised steel trim finish as standard• Opal diffuser as standard/Wall or ceiling mounted• Please specify /CH (Chrome) /PB (Polished Brass) Other colours on request• Screen Print/Prismatic diffuser on request/Sticker legends (Page 74)• Also available with NETCOM 5XP (Page 70)• Available with Auto-Test (Page 9)

300 SERIES

Page 30: Ventilux Buyers Guide

VerseEscape Route

30

Specifically designed to please the most discerning ofarchitects and consultants, while retaining the contractor’s needs as a priority, the Verse is a compactand stylish solution to all Emergency Lighting specifiersneeds.

Purpose-designed for interior use (IP42), the Verseoffers a versatility in application second to none. Theluminaire includes a flame retardant ABS body and allows the geartray and reflector assembly to bepositioned on the base to allow downlight.

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify 24 / 50 / 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time periode.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: 360 x 180 x 60 (mm)• White finish as standard/Wall or ceiling mounted• Clear Polycarbonate diffuser• Please specify /CH (Chrome) /PB (Polished Brass) Other colours on request• Prismatic diffuser on request/Sticker legends (Page 74) • Also available with NETCOM 5XP (Page 70)• Available with Auto-Test/Push-Test function (Page 9)

Product Code Operation Lamp Battery Lumen VA Weight

Escape RouteVRM3/F8 M T5-8 Watt 2.4V / 4.5A/h 78 20 1.5kgVRNM3/F8 N-M T5-8 Watt 2.4V / 4.5A/h 87 8 1.2kgVRM3/LED/1W M LED-1 Watt 4.8V / 1.3A/h 120 5 1.5kgVRNM3/LED/1W N-M LED-1 Watt 4.8V / 1.3A/h 120 2.3 1.2kg

Exit SignageVRM3/F8/EXIT M T5-8 Watt 2.4V / 4.5A/h N/A 20 1.5kgVRNM3/F8/EXIT N-M T5-8 Watt 2.4V / 4.5A/h N/A 8 1.2kgVRM3/LED/EXIT M LED-1 Watt 4.8V / 1.3A/h N/A 4 1.0kgVRNM3/LED/EXIT N-M LED-1 Watt 4.8V / 1.3A/h N/A 2 1.0kg

*Please specify /240v after the above code for mains operation*Please specify /3C after the above code for 3 Cell High Output Battery

View From 22M

Page 31: Ventilux Buyers Guide

VantageEscape Route

Subtlety, flexibility and ease of installation are the keyfeatures of this recessed fitting. Designed for indoor installation in a wide range of public and commerciallocations, the sleek aesthetics of the flush mountedVantage make it the ideal solution wherever discreetemergency lighting is required.

The standard recessed luminaire can be transformedinto an edge lit product, by means of a slotted diffuserand hanging panel option, with all signage complyingwith European Directives.

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify 24 / 50 / 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: 426 x 161 x 86 (mm)• White ABS body with Clear Polycarbonate diffuser as standard (IP20)• Recessed Ceiling Mounted• Please specify /CH (Chrome) /PB (Polished Brass) Other colours on request• Opal diffuser on request• Directional panels (Page 74)• Also available with NETCOM 5XP (Page 70)• Available with Auto-Test/Push- Test function (Page 9)

Product Code Operation Lamp Battery Lumen VA Weight

Escape RouteVAM3/F8 M T5-8 Watt 2.4V / 4.5A/h 78 20 1.9kgVANM3/F8 N-M T5-8 Watt 2.4V / 4.5A/h 87 8 1.6kgVAM3/LED/1W M LED-1 Watt 4.8V / 1.3A/h 120 5 1.9kgVANM3/LED/1W N-M LED-1 Watt 4.8V / 1.3A/h 120 2.3 1.6kg

Exit SignageVAM3/F8/EXIT M T5-8 Watt 2.4V / 4.5A/h N/A 20 2.0kgVANM3/F8/EXIT N-M T5-8 Watt 2.4V / 4.5A/h N/A 8 1.7kgVAM3/LED/EXIT M LED-1 Watt 4.8V / 1.3A/h N/A 4 1.4kgVANM3/LED/EXIT N-M LED-1 Watt 4.8V / 1.3A/h N/A 2 1.4kg

*Please specify /240v after the above code for mains operation*Please specify /3C after the above code for 3 Cell High Output Battery

31

View From 30M

Page 32: Ventilux Buyers Guide

Eclipse MiniEscape Route

32

A complete range of ultra low profile luminaires suitablefor wall and ceiling mounting. Unique styling withmoulded caps and coated extruded aluminium side railshas made the range popular with consultants, architectsand users alike.

Both Eclipse Maxi and Mini can be used as bulkheadsto illuminate escape routes, or as directional exit signswith European Directive Format self-adhesive legendsor custom screen-print solutions.

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify 24 / 50 / 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time periode.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: 460 x 180 x 65 (mm)• Surface or ceiling mounted• White ABS body with Opal Polycarbonate diffuser as standard (IP42)• Screen Print diffuser on request/Sticker legends (Page 74)• Please specify /CH (Chrome) /PB (Polished Brass) Other colours on request• Also available with NETCOM 5XP (Page 70)• Available with Auto-Test/Push-Test function (Page 9)

Product Code Operation Lamp Battery Lumen VA Weight

Escape RouteBKM3/F8 M T5-8 Watt 2.4V / 4.5A/h 78 20 1.9kgBKNM3/F8 N-M T5-8 Watt 2.4V / 4.5A/h 87 8 1.6kg

Exit SignageBKM3/F8/EXIT M T5-8 Watt 2.4V / 4.5A/h N/A 20 2.0kgBKNM3/F8/EXIT N-M T5-8 Watt 2.4V / 4.5A/h N/A 8 1.7kgBKM3/LED/EXIT M LED-1 Watt 4.8V / 1.3A/h N/A 4 1.4kgBKNM3/LED/EXIT N-M LED-1 Watt 4.8V / 1.3A/h N/A 2 1.4kg

*Please specify /240v after the above code for mains operation*Please specify /3C after the above code for 3 Cell High Output Battery

View From 30M

Page 33: Ventilux Buyers Guide

Eclipse MaxiEscape Route

The Eclipse Maxi and Mini are available as self-contained or centrally supplied emergency luminairesand are perfectly suited for use in conjunction with either of Ventilux’s two testing systems, Netcom5 orAutotest.

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify 24 / 50 / 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: 515 x 235 x 65 (mm)• Surface or ceiling mounted• White ABS body with Opal Polycarbonate diffuser as standard (IP42)• Screen Print diffuser on request/Sticker legends (Page 74)• Please specify /CH (Chrome) /PB (Polished Brass) Other colours on request• Also available with NETCOM 5XP (Page 70)• Available with Auto-Test/Push-Test function (Page 9)

Product Code Operation Lamp Battery Lumen VA Weight

Escape RouteEKM3/F8 M T5-8 Watt 2.4V / 4.5A/h 78 20 2.2kgEKNM3/F8 N-M T5-8 Watt 2.4V / 4.5A/h 87 8 1.9kg

Exit SignageEKM3/F8/EXIT M T5-8 Watt 2.4V / 4.5A/h N/A 20 2.3kgEKNM3/F8/EXIT N-M T5-8 Watt 2.4V / 4.5A/h N/A 8 2.0kgEKM3/LED/EXIT M LED-1 Watt 4.8V / 1.3A/h N/A 4 1.7kgEKNM3/LED/EXIT N-M LED-1 Watt 4.8V / 1.3A/h N/A 2 1.7kg

*Please specify /240v after the above code for mains operation*Please specify /3C after the above code for 3 Cell High Output Battery

33

View From 30M

515 mm

235

mm

300 SERIES

Page 34: Ventilux Buyers Guide

34

Stylux Recessed& Halo LED

Page 35: Ventilux Buyers Guide

35 Vista LED

Page 36: Ventilux Buyers Guide

36

Page 37: Ventilux Buyers Guide

Exit

Sign

age

37

Page 38: Ventilux Buyers Guide

ExluxExit Signage

The Exlux Sign Luminaire is versatile, unobtrusive andeconomic. Designed to satisfy statutory requirementsfor Exit Signs using panels selected from the comprehensive range of types available, which will correctly indicate the direction of the escape route.

Available in white powder coated sheet steel, the housing provides downlight through carefully designedpanels in the lower surface to assist in the illuminationof the emergency escape route.

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify 24 / 50 / 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time periode.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: 430 x 200 x 60 (mm)• White finish as standard (IP42)• Available in chrome/CH, Polished Brass/BR and other colours on request• Black theatre/cinema version available• High temperature Ni-Cd or Ni-Mh battery• Side and top 20mm conduit entries and rear BESA box entry• Directional panels (page 74)• Also available with NETCOM 5XP or Dali addressable• Available with Auto-Test/Push-Test function (Page 9)

Product Code Operation Lamp Battery Lumen VA Weight

Escape RouteEXM3/F8 M T5-8 watt 4.8V / 1.3A/h 20 43 2.1kgEXNM3/F8 N-M T5-8 watt 4.8V / 1.3A/h 87 5 1.2kgEXS3/F8 Sustained T5-8 watt 2.4V / 4.5A/h 87 43 2.6kgEXM3/LED M LED 4.8V / 1.3A/h 20 10 2.1kgEXNM3/LED N-M LED 4.8V / 1.3A/h 20 4 2.1kg

* Please specify /DS for Double Sided

View From 36M

* Please specify /TL for Tiller Lamp

38

Page 39: Ventilux Buyers Guide

Exlux PlusExit Signage

The Exlux Plus sign luminaire is a versatile, solution toapplications requiring a larger than normal viewing distance.

With a 58 metre viewing distance this larger than normal exit sign has numerous applications for indoorand outdoor installation in a range of commercial andindustrial locations.

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify 24 / 50 / 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: 730 x 300 x 160 (mm)• White finish as standard (IP42)• Available in chrome/CH, Polished Brass/BR and other colours on request• High temperature Ni-Cd or Ni-Mh battery• Side and top 20mm conduit entries and rear BESA box entry• Directional panels (page 74)• Also available with NETCOM 5XP or Dali addressable• Available with Auto-Test/Push-Test function (Page 9)

39

Product Code Operation Lamp Battery Lumen VA Weight

Escape RouteEX+M3/F18 M T5-18 Watt 3.6V / 4.5A/h 151 38 6.4kgEX+NM3/F18 N-M T5-18 Watt 3.6V / 4.5A/h 173 12 6.4kgEX+M3/LED M LED 4.8 V /1.3A/h 32 27 6.1kgEX+NM3/LED N-M LED 4.8 V /1.3A/h 32 4 6.1kg

* Please specify /DS for Double Sided

View From 58M

IP65

O

Page 40: Ventilux Buyers Guide

VasariExit Signage

View From 36M

Product Code Operation Lamp Battery Lumen VA Weight

VAIM3/F8 M T5-8 Watt 2.4V / 4.5A/h 78 20 2.8kgVAINM3/F8 N-M T5-8 Watt 2.4V / 4.5A/h 87 8 2.5kgVAIM3/LED M LED 4.8V / 1.3A/h 10 10 2.3kgVAINM3/LED N-M LED 4.8V / 1.3A/h 10 4 2.3kg

40

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify 24 / 50 / 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: 442.5 x 363 x 92 (mm)• Polycarbonate diffuser as standard• High temperature Ni-Cd or Ni-Mh battery• Two 20mm conduit entries at the rear of body• White finish as standard (IP42)• Available in chrome/CH, Polished Brass/BR and other colours on request• Directional panels (page 77)• Also available with NETCOM 5XP or DALI addressable• Available with Auto-Test / Push-Test function (Page 9)

* Please specify / TL (Tiller Lamp)

The Vasari LED luminaire is a versatile and stylishemergency luminaire.

Offering 10 high intensity white LEDs as the alternativelamp source compared to a conventional 8 watt tube,the Vasari LED offers the client a long term maintenanceand operational cost saving, compared to conventional8 watt luminaires.

Available in white-powder coated sheet steel, or with apolished brass finish, the housing provides a versatileceiling or wall mounted option.

Page 41: Ventilux Buyers Guide

GladeExit Signage

Engineered with ease of installation and cost effectiveness as a focus, the Glade achieves its’ goalswhile offering an exciting aesthetic to rival any edgelitsign luminaire on the market.

The Glade geartray is fixed to the wall or ceiling as afirst fix, and the rest of the assembly simply clips together.

The unique panel assembly ensures the perfect blendof clean, aesthetic and highly illuminated signage.

Product Code Operation Lamp Battery Lumen VA Weight

GDM3/F8 M T5 - 8 watt 2.4V / 4.5A/h 78 20 3.1kgGDNM3/F8 N-M T5 - 8 watt 2.4V / 4.5A/h 87 8 2.8kgGDM3/LED M LED 4.8V / 1.3 A/h 10 10 2.6kgGDNM3/LED N-M LED 4.8V / 1.3A/h 10 4 2.6kg

41

View From 36M

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify 24 / 50 / 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: 460 x 505 x 102 (mm)• Chrome finish as standard (IP42)• Available in Polished Brass/BR and other colours on request• Directional panels (page 74)• Also available with NETCOM 5XP or DALI addressable• Available with Auto-Test / Push-Test function

Page 42: Ventilux Buyers Guide

StyluxExit Signage

42

Designed to satisfy the statutory requirements for indoor exit signs the Stylux luminaire is ideal for thoseinstallations where there is an emphasis on clear andaesthetic signage.

Allowing versatility for each application, the Stylux canbe wall or ceiling mounted. In addition it can be fitted with a cantilever wall bracket to allow further installation flexibility to the client.

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify 24 / 50 / 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time periode.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: 345 x 285 x 60 (mm)• Polycarbonate diffuser as standard (IP42)• High temperature Ni-Cd or Ni-Mh battery• White / WH, chrome/CH, Polished Brass/BR finish as standard • Other colours available on request• Directional panels (page 74)• Also available with NETCOM 5XP• Available with Auto-Test/Push-Test function (Page 9)

Product Code Operation Lamp Battery Lumen VA Weight

STM3/F8 M T5-8 Watt 2.4V / 4.5A/h 78 20 2.0kgSTNM3/F8 N-M T5-8 Watt 2.4V / 4.5A/h 87 8 1.9kgSTM3/LED M LED 4.8V / 1.3A/h 10 5 2.0kgSTNM3/LED N-M LED 4.8V / 1.3A/h 10 3 1.9kg

View From 28M*Please specify /TL (Tiller Lamp)

*/PB for Polished Brass

Page 43: Ventilux Buyers Guide

Exit SignageAs an alternative to the standard Stylux blade exit signluminaires, the Ventilux Stylux Recessed provides thesame combination of style and design in a high qualityluminaire in which all of the control equipment is fullyrecessed into the ceiling.

All versions of the Stylux luminaires are designed andmanufactured to meet current and future product standards and the appropriate requirements of all EUdirectives.

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify 24 / 50 / 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: 508 x 112 x 288 (mm)• Polycarbonate diffuser as standard• High temperature Ni-Cd or Ni-Mh battery• Two 20mm conduit entries at side and rear surface of recessed body• White, chrome or Polished Brass finish as standard (IP42)• Other colours available on request• Directional panels (page 74)• Also available with NETCOM 5XP or DALI addressable• Available with Auto Test / Push Test function (Page 9)

Product Code Operation Lamp Battery Lumen VA Weight

RSTM3/F8 M T5-8 Watt 2.4V / 4.5A/h 78 20 2.8kgRSTNM3/F8 N-M T5-8 Watt 2.4V / 4.5A/h 87 8 2.5kgRSTM3/LED M LED 4.8V / 1.3A/h 10 10 2.3kgRSTNM3/LED N-M LED 4.8V / 1.3A/h 10 4 2.3kg

Stylux Recessed

View From 36M

43

*Please specify /TL (Tiller Lamp)

Page 44: Ventilux Buyers Guide

FocalExit Signage

44

Another industry first from Ventilux. A unique combination of engineering and design makes Focal anideal choice for all installations where emergency lighting is to be an integral part of the overall design.The main body is manufactured from an aluminiumcasting that houses the concave reflector and legendpanels.

Specifically designed to compliment the latest trends ininterior design and architectural practice, Focal is asleek departure from the norm in Emergency Lighting signage. Focal is ideal for those installations wherethere is an emphasis on clear signage and aesthetic appearance.

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify 24 / 50 / 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time periode.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: 648 x 225 x 60 (mm)• High temperature Ni-Cd or Ni-Mh battery.• Two 20mm conduit entries at rear• Stainless steel finish as standard (IP42)• Available in chrome/CH and other colours on request• Directional panels (page 74)• Also available with NETCOM 5XP or DALI addressable• Available with Auto-Test/Push-Test function (Page 9)

Product Code Operation Lamp Battery Lumen VA Weight

FLM3/F8 M T5-8 Watt 2.4V / 4.5A/h 78 20 3.2kgFLNM3/F8 N-M T5-8 Watt 2.4V / 4.5A/h 87 8 2.9kgFLM3/LED M LED 4.8V / 1.3A/h 8 10 2.7kgFLNM3/LED N-M LED 4.8V / 1.3A/h 8 4 2.7kg

View From 36M

Page 45: Ventilux Buyers Guide

Eclipse DualExit Signage

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify 24 / 50 / 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: 440 x 260 x 65 (mm)• Flame Retardant ABS body• High temperature Ni-Cd or Ni-Mh battery.• BESA box mounting as standard• White finish as standard (IP42)• Available in chrome/CH, Polished Brass/BR and other colours on request• Directional panels (page 74)• Also available with NETCOM 5XP or Dali addressable• Available with Auto-Test/Push-Test function (Page 9)

Product Code Operation Lamp Battery Lumen VA Weight

DKM3/F8 M T5-8 Watt 2.4V / 4.5A/h 78 20 1.8kgDKNM3/F8 N-M T5-8 Watt 2.4V / 4.5A/h 20 8 1.3kgDKM3/LED M LED 4.8V / 1.3A/h 20 10 1.3kgDKNM3/LED N-M LED 4.8V / 1.3A/h 20 4 1.3kg

45

View From 22M

Designed in conjunction with the Eclipse Maxi and Mini,this double sided sign follows their ultra slim styling,making the Eclipse range a leading concept in emergency lighting design.

The Eclipse Dual’s design ensures an ease of installation coupled with sleek lines, which combine tomake it the natural choice of both specifying consultantsand contractors alike.

Available as a self-contained or centrally supplied emergency luminaire, the Eclipse is built and tested to current European standards and is designed to complywith all relevant EU directives.

Page 46: Ventilux Buyers Guide

VanguardExit Signage

46

The development of the Vanguard range marks yet another unique progression in emergency lighting.

Designed to seamlessly integrate into the interior aesthetics of prestigious modern developments, and produced from the highest quality materials, the Vanguard range will appeal to architects, consultantsand contractors who require a flexible and innovativeapproach to emergency lighting.

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify 24 / 50 / 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time periode.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: Surface Mounted Version- 298 x 100 x 75 (mm)• Stainless Steel housing with 4mm or 10mm Screen Print Legend (IP20)• Other colours on request• Multiple mounting option (Other dimensions on request) • High temperature Ni-Mh battery• Directional panels (page 74)• Also available with NETCOM 5XP (Page 70)• Available with Auto-Test/Push-Test function (Page 9)

Product Code Operation Lamp Battery Lumen VA Weight

VGM3/LED M LED 4.8V / 1.3A/h 8 4 2.9kgVGNM3/LED N-M LED 4.8V / 1.3A/h 8 2 2.9kgView From 34M

/ WM for wall mounted/CM for ceiling mounted

Page 47: Ventilux Buyers Guide

VanguardExit Signage

The family of products is specifically designed to enablea cohesive directional emergency lighting solution,adaptable to all mounting scenarios within a specifiedproject.

47

Wall mounted bracket option VGD/WBK

Wall mounted option /VGD/WKB

A

B

A

Page 48: Ventilux Buyers Guide

VistaExit Signage

Single-Sided

48

Designed to seamlessly integrate into the interior aesthetic of prestigious modern developments andproduced from the highest quality materials, the VistaRange will appeal to architects and consultants who require flexible and innovative approach to emergencylighting.

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify 24 / 50 / 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time periode.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: Surface Mounted Version- 464x200x96 (mm)• Stainless Steel housing with opal polycarbonate legend (IP20)• Other colours on request• Multiple mounting option • High temperature Ni-Cd or Ni-Mh battery• Directional panels (page 74)• Also available with NETCOM 5XP or DALI (Page 70)• Available with Auto-Test/Push-Test function (Page 9)

Product Code Operation Lamp Battery Lumen VA Weight

VTM3/LED M LED 4.8V / 1.3A/h 8 8 2.6kgVTNM3/LED N-M LED 4.8V / 1.3A/h 8 4 2.6kgVTM3/F8 M T5-8 watt 2.4V / 4.5A/h 78 20 3.2kgVTNM3/F8 N-M T5-8 watt 2.4V / 4.5A/h 87 8 2.9kg

View From 34M

Page 49: Ventilux Buyers Guide

VistaExit Signage

Double-Sided

This family of products is specifically designed to enablea cohesive directional emergency lighting solution,adaptable to all mounting scenarios within a specificproject.

Product Code Operation Lamp Battery Lumen VA Weight

VTM3/LED/2 M LED 4.8V / 1.3A/h 8 8 2.6kgVTNM3/LED/2 N-M LED 4.8V / 1.3A/h 8 4 2.6kgVTM3/F8/2 M T5-8 Watt 2.4V / 4.5A/h 78 20 3.2kgVTNM3/F8/2 N-M T5-8 Watt 2.4V / 4.5A/h 87 8 2.9kg

49

View From 34M

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify 24 / 50 / 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time periode.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: Surface Mounted Version- 464x200x96 (mm)• Stainless Steel housing with opal polycarbonate legend (IP20)• Other colours on request• Multiple mounting option • High temperature Ni-Cd or Ni-Mh battery• Directional panels (Page 74)• Also available with NETCOM 5XP (Page 70)• Available with Auto-Test/Push-Test function (Page 9)

Mounting kits available• Order VT/BCK for bracket ceiling kit• Order VT/BWK for bracket wall kit• Order VT/FCK for flush ceiling kit• Order VT/FWK for flush wall kit

Please note these mounting kits are not supplied asstandard and need to be ordered separately with standard product.

Page 50: Ventilux Buyers Guide

VisageExit Signage

50

Designed for indoor and outdoor installation in a rangeof commercial and industrial locations, the compact Visage Luminaire offers a high level of specification,ease of installation and excellent value for money.

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify 24 / 50 / 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time periode.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: 368 x 304 x 150 (mm)• Opal polycarbonate diffuser• Flame retardant ABS body• High temperature Ni-Cd or Ni-Mh batteryª Side and end 20mm conduit entries and rear BESA box mounting as standard• White finish as standard • Other colours available on request• Sticker legends (page 74)• Also available with NETCOM 5XP or DALI (Page 70)• Available with Auto-Test/Push-Test function (Page 9)

Product Code Operation Lamp Battery Lumen VA Weight

VGM3/F8 M T5-8 Watt 2.4V / 4.5A/h 78 20 2.2kgVGNM3/F8 N-M T5-8 Watt 2.4V / 4.5A/h 87 8 1.9kgVGM3/LED M LED 4.8V /1.3A/h 8 10 1.7kgVGNM3/LED N-M LED 4.8V / 1.3A/h 8 4 1.7kg

IP65

OView From 22M

Page 51: Ventilux Buyers Guide

Exlux IP67Exit Signage

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify 24 / 50 / 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: 379 x 189 x 130 (mm)• Flame retardant ABS housing with polycarbonate diffuser• Other colours on request• High temperature Ni-Cd or Ni-Mh battery• Directional panels (Page 74)• Also available with NETCOM 5XP or DALI (Page 70)• Available with Auto-Test/Push-Test function (Page 9)

Product Code Operation Lamp Battery Lumen VA Weight

EXM3/F8/IP65 M T5-8 Watt 3.6V/4.5A/h 78 20 3.4kgEXNM3/F8/IP65 N-M T5-8 Watt 3.6V/4.5A/h 87 8 3.1kgEXM3/LED/IP65 M LED 4.8V/1.3A/h 20 4 2.9kgEXNM3/LED/IP65 N-M LED 4.8V/1.3A/h 20 2 2.9kg

51

IP67

OView From 30M

The robust and durable design of the Exlux IP67Luminaire makes it ideal for a range of exterior and selected interior locations. Operators of leisure centre,car parks, sports facilities, factories and undergroundwalkways will benefit from its tough, resistant construction and ease of installation.

Page 52: Ventilux Buyers Guide

52 Focal LED...

Page 53: Ventilux Buyers Guide

Twin

spot

s & T

ungs

ten

Halo

gen

Ligh

ting

53

Page 54: Ventilux Buyers Guide

ScoutTwinspots & Tugsten Halogen Lighting

54

Purpose designed for interior use, the Scout luminairehouses a unique swivel and rotate system, which allowsindependent positioning of the projectors, giving the installer more flexibility on installation.

Unlike other twin projector luminaires, the Scout notonly includes a unique rotate reflector system, but alsoan aesthetically pleasing compact enclosure which willblend into almost any decor, where open area lightingmust be provided to direct persons escaping along thedefined escape route.

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time periode.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: 384 x 214 x 132 (mm)• Stainless Steel housing (IP20)• Maintenance free sealed lead acid battery• Available in /WH (White) /BR (Polished Brass) Other colours on request• Surface or Semi-Recessed housing• Also available with Remote Lamps complete with Bracket• Also available with NETCOM 5XP (Page 70)• Available with Auto-Test/Push-Test function (Page 9)

Product Code Operation Lamp Battery Lumen VA Weight

SC10/NM3 N-M TH-2 x 10 Watt 12V / 7.0A/h 280 40 5.4kgSC20/NM3 N-M TH-2 x 20 Watt 12V / 14.0A/h 600 40 7.8kgSC6LED/NM3 N-M LED-2 x 3Watt 4.8V / 4.5A/h 360 8.9 7.8kg

Black Finish

/PB for Polished Brass */WH for white

Page 55: Ventilux Buyers Guide

CoronaTwinspots & Tugsten Halogen Lighting

Purpose designed for interior use, the Corona luminaire is designed to fit into a hole size of 135mm,and comes in two parts, giving the installer more flexibility and ease on installation.

Semi-recessed, to yield a depth of only 13mm, the Corona is the discreet option of stylish Emergency Lighting installations.

55

Silver FinishBrass Finish Black Finish

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: 168 * 36.50 (mm)• Discrete pressed-steel hosuing with aluminium spun reflector (IP20)• Available in /WH (White) /BR (Polished Brass) /CH (Chrome) Other colours on request• Maintenance free sealed lead acid battery• Also available with NETCOM 5XP (Page 70)• Available with Auto-Test/Push-Test function (Page 9)

Product Code Operation Lamp Battery Lumen Weight

CANM3/5TH N-M TH-5 Watt 12V/7.0A/h 60 4.6kgCANM3/10TH N-M TH-10 Watt 12V/7.0A/h 140 4.6kgCANM3/20TH N-M TH-20 Watt 12V/7.0A/h 300 4.6kg

Page 56: Ventilux Buyers Guide

TwinluxTwinspots & Tugsten Halogen Lighting

56

For industrial areas, factories or warehouses with aislesand specific hazards causing obstruction, open arealighting must be provided to direct persons escapingonto the defined escape route.

The provision of Emergency Lighting in these areas isbest achieved through the use of Ventilux Twinlux TwinProjector Luminaires.

Designed to project the light output from the high efficiency halogen lamps exactly where needed, theseluminaires can be provided in versions suitable for normal interior applications or with either IP55 or IP67degree of protection from dust and water ingress.

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time periode.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: 360 x 180 x 60 (mm)• White/Grey powder coated galvanised sheet steel• Other colours on request• Maintenance free sealed lead acid battery• Deep battery discharge protection circuitry• Polycarbonate lenses upon request for food preperation areas• Wide rotational lamp head (360°)• Also available with Remote Lamps complete with bracket• Delay timer optional• Also available with NETCOM 5XP (Page 70)• Available with Auto-Test/Push-Test function (Page 9)

Product Code Operation Lamp Battery Lumen VA Weight

TL20/NM3 N-M TH-2 x 20 Watt 12V/14.0A/h 600 24 9.4kgTL55/NM3 N-M TH-2 x 55 Watt 12V/42.0A/h 1900 24 22kg

IP67WTL20/NM3 N-M TH-2 x 20 Watt 12V/14.0A/h 600 24 9.0kgWTL55/NM3 N-M TH-2 x 55 Watt 12V/42.0A/h 1900 24 21kg

*please note WLT20/NM3 supplied withlamps underneath housing as standard.WTL55/TL20/TL55 supplied with lampson top of housing.

TL20 Product

Page 57: Ventilux Buyers Guide

TwinluxTwinspots & Tugsten Halogen Lighting

57

Page 58: Ventilux Buyers Guide

CTL - Compact Twin Lamp

Twinspots & Tugsten Halogen Lighting

58

The Compact Twinspot (CTL) range of luminaires havebeen specifically designed to provide emergency lighting in high bay industrial areas, factories or largewarehouses where there is a requirement to projecthigh intensity beams between the racks and equipmentto illuminate walkways and assist safe evacuation incase of emergency.

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time periode.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: 330 x 210 x 69 (mm)• White/Grey powder coated galvanised sheet steel (IP20)• Other colours on request• Maintenance free sealed lead acid battery• Deep battery discharge protection circuitry• Polycarbonate lenses upon request for food preperation areas• Wide rotational lamp head• Also available with Remote Lamps complete with bracket• Delay timer optional• Also available with NETCOM 5XP (Page 70)• Available with Auto-Test/Push-Test function (Page 9)

*/BL for Black

LED indication of correct charger function and lamp filaments continuity.

Product Code Operation Lamp Battery Lumen VA Weight

CTL20/NM3 N-M TH-2 x 20 Watt 12V/ 14.0A/h 600 24 9.4kg

Page 59: Ventilux Buyers Guide

59 Emer

genc

y Co

nver

sion

Pow

er P

acks

Page 60: Ventilux Buyers Guide

60

Independent LED Conversion Module

Emergency Conversion Power PacksThe exceptionally low profile 'Indepentent' KPLEDconversion kit can be fitted inside the latest generationslimline luminaires and offers a cost effective solutionto conventional linear fluorescent lamp conversions.

Purpose designed to provide emergency lighting con-version of all mains lighting luminaires, the convertaluxKPLED series has been designed specifically to operatefully independent of the existing high frequency ballast,allowing a much easier and lower-risk conversion.

• Assembly complete with charge indicating LED, Battery Pack and Clips.• Suitable for integral and remote mounting options.• Lamp head suitable for mounting on plastic surfaces due to integral heat sink.• LEDs manufactured by CREE.• 1 watt option provides 100 lumens in emergency operation.• 3 watt option provides 180 lumens in emergency operation.• 3x1 watt option provides 300 lumens in emergency operation.• Module dimensions 148 x 25 x 27 mm.

Product Code Description Range of LED Lamps Lumens

KPNMC-4-1 1 watt LED inverter module 1 watt @ 350mA 100KPNMC-4-3 3 watt LED inverter module 3 watt @ 650mA 180KPNMC-4-3 3x1 watt LED inverter module 3 x 1 watt @ 350mA 300

* Add RP instead of KP for remote hosuing assembly for example RPNMC-4-1* Please add /DL for Downlighter Conversions

Page 61: Ventilux Buyers Guide

Mains LED Conversion Module

Emergency Conversion Power PacksThe Mains LED conversion kit can be fitted inside thelatest LED linear and LED down lighter luminaires. This module offers a cost effective solution to linear anddown lighter fluorescent lamp conversions.

The low profile module incorporates a constant currentbattery charger suitable to recharge and maintain thecharge of the connected nickel cadmium battery.

The key benefit of this unit is just the output is configurable to seven separate output voltage/currentconfigurations, to cover a wide range of LED types andmains wattages.

• Low profile slimline module suitable for the conversion of LED mains applications.• Compatible with all high frequency mains ballasts via on-board switched live contacts.• High efficiency LED driver for excellent emergency lumen output.• LED conversion pack electrically isolated from mains control gear.• Module dimensions 170 x 35 x 38 mm.• Enclosure fixing centre 160 mm.• Assembly complete with charge indicating LED, Battery Pack and Clips.• Suitable for integral and remote mounting options.• Suitable for use with Ni-Mh or Ni-Cd batteries.

Product Code Description Range of LED Lamps

KPM-4-5W/12V 5 Watt LED Inverter Module 390 mA @ 12vKPM-4-5W/18V 5 Watt LED Inverter Module 260 mA @ 18v KPM-4-5W/27V 5 Watt LED Inverter Module 175 mA @ 27v KPM-4-5W/36V 5 Watt LED Inverter Module 130 mA @ 36vKPM-5-5W/40V 5 Watt LED Inverter Module 125 mA @ 40vKPM-5-5W/50V 5 Watt LED Inverter Module 100 mA @ 50vKPM-5-5W/65V 5 Watt LED Inverter Module 77 mA @ 65v

* please note to establish whether a mains LED luminaire can be converted is basedon secondary output voltage and not wattage.

61

Page 62: Ventilux Buyers Guide

Convertalux KPHFM Series

Emergency Conversion Power Packs

62

The Convertalux KPHFM Seriess is a low profile conversion kit for mains luminaires with 7 to 85 wattfluorescent lamps with or without remote mounting.Suitable for both switch start and high frequency controlgear. Assembly complete with charge indicating LED,Battery Pack and Clips.

• Remote Pack Dimensions: 145 x 55 x 395 (mm)• All conversion module supplied with high temperature

Ni-Cd batteries• Ni-Mh batteries available on request• 20mm conduit entries in end and rear surfaces of

remote mounting box• IP65 remote pack available on request

Product Code Description Range of Lamps BLF

KPHFM-3-18 18 watt T8 inverter module, 18 watt PLL 0.15complete with battery and charge LED 7 watt PLS 0.29

9 watt PLS 0.2110 watt PLC 0.384 watt T5 0.396 watt T5 0.338 watt T5 0.3118 watt T8 0.16

KPHFM-4-58 58 watt T8 inverter module, complete with 11 watt PLS 0.17battery and charge LED 18 watt PLL 0.14

36 watt PLL 0.1213 watt PLC 0.2618 watt PLC 0.1926 watt PLC 0.1918 watt TCT 0.1740 watt T12 0.0965 watt T12 0.0736 watt T8 0.0958 watt T8 0.08

KPHFM-4-28 28 watt 2D inverter module, complete with 16 watt 2D 0.21battery and charge LED 28 watt 2D 0.14

KPHFM-5-38 38 watt 2D inverter module, complete with 38 watt 2D 0.12battery and charge LED

KPHFM-5-70 70 watt T8 inverter module, complete 70 watt T8 0.07with battery and charge LED 85 watt T12 0.09

Page 63: Ventilux Buyers Guide

ConvertaluxKPT5 Series

Emergency Conversion Power PacksThe Convertalux KPT5 Series is an emergency conversion module designed to fit into the latest generation T5, TCT and PLL slimline luminaires. Suitablefor both switch start and high frequency control gear.Assembly complete with charge indicating LED BatteryPack and Clips.

• Assembly complete with charge indicating LED, Battery Pack and Clips.• Remote Pack Dimensions: 145 x 55 x 395 (mm)• All conversion modules supplied with high temperature Ni-Cd batteries• Ni-Mh batteries available on request• 20mm conduit entries in end and rear surfaces of remote mounting box• IP65 remote pack available on request

Product Code Description Range of Lamps BLF

KPHFM-4-14/HE 14 watt T5 inverter module 14 watt T5 HE 0.23KPHFM-6-21/HE 21 watt T5 inverter module 21 watt T5 HE 0.19KPHFM-6-24/HO 24 watt T5 inverter module 24 watt T5 HO 0.12KPHFM-6-28/HE 28 watt T5 inverter module 28 watt T5 HE 0.13KPHFM-6-35/HE 35 watt T5 inverter module 35 watt T5 HE 0.12KPHFM-6-39/HE 39 watt T5 inverter module 39 watt T5 HO 0.12KPHFM-6-49/HE 49 watt T5 inverter module 49 watt T5 HO 0.09KPHFM-6-54/HE 54 watt T5 inverter module 54 watt T5 HO 0.08KPHFM-6-80/HE 80 watt T5 inverter module 80 watt T5 HO 0.06KPHFM-6-18/TCT 18 watt TCT invertermodule 18 watt TCT 0.18KPHFM-6-24/TCT 24 watt TCT inverter module 24 watt TCT 0.14KPHFM-6-26/TCT 26 watt TCT inverter module 26 watt TCT 0.14KPHFM-6-32/TCT 32 watt TCT inverter module 32 watt TCT 0.13KPFM-6-42/TCT 42 watt TCT inverter module 42 watt TCT 0.07KPHFM-6-40/PLL 40 watt PLL inverter module 40 watt PLL 0.10KPHFM-6-55/PLL 55 watt PLL inverter module 55 watt PLl 0.06KPHFM-6-40/CIR 40 watt CIR inverter module 40 watt Circular 0.10

* Please specify RP instead of KP in above code for remote housing assembly.

63

Page 64: Ventilux Buyers Guide

LED MR16Conversion Pack

Emergency Conversion Power Packs

64

The Ventilux LED 5 watt and 10 watt MR16 conversion kits are designed to convert the latest 10watt low voltage MR16 LED down lighters to emergencylighting operation.

Housed in a flexible silicone coated fiberglass enclosurethe product is designed to pass through a 65mm diameter hole in the ceiling. The silicone coated enclosure provides excellent electrical isolation, hightemperature resistance and corrosion resistance.

• Can be used for Non-Maintained or Maintained operation.• Lamp supplied as standard by Ventilux.• Assembly complete with charge indicating LED.• 5 watt comparable to 12 V / 20W Tungsten Halogen.• 10 watt comparable to 12 V / 50W Tungsten Halogen.• Suitable for through hole mounting and connection via a 65mm cut-out.• Suitable for a ceiling void of 110mm.

Product Code Operation Lamp Cut-out Ceiling Void Battery Weight

VLEDSP5/NM3 N-M LED / 5 W 65mm 110mm 4.8V / 4.5A/h 1.1kgVLEDSP5/M3 M LED / 5 W 65mm 110mm 4.8V / 4.5A/h 1.1kgVLEDSP10/NM3 N-M LED / 10 W 65mm 110mm 12V / 4.5A/h 1.45kgVLEDSP10/M3 M LED / 10 W 65mm 110mm 12V / 4.5A/h 1.45kg

800 mm

60 mm

Page 65: Ventilux Buyers Guide

Emergency Conversion Power Packs

Product Code Operation Lamp Cut-out Ceiling Void BLF Battery Weight

THSP20/NM3 N-M 12V / 20W TH 80mm 110mm 8% 6V / 5.0A/h 1.85kgTHSP20/M3 M 12V / 20W TH 80mm 110mm 8% 6V / 5.0A/h 1.85kgTHSP50/NM3 N-M 12V / 50W TH 80mm 110mm 8% 6V / 14.0A/h 4.6kgTHSP50/M3 M 12V / 50W TH 80mm 110mm 8% 6V / 14.0A/h 4.6kgTHSP20/NM3/NIMH N-M 12V / 20W TH 65mm 220mm 10% 6V / 7.0A/h 1.75kgTHSP20/M3/NIMH M 12V / 20W TH 65mm 220mm 10% 6V / 7.0A/h 1.75kgTHSP50/NM3/NIMH N-M 12V / 50W TH 65mm 220mm 10% 6V / 13.0A/h 1.95kgTHSP50/M3/NIMH M 12V / 50W TH 65mm 220mm 10% 6V / 13.0A/h 1.95kg

* For a maintained product specify when ordering whether a maintained transformer is required

65

THSP50/NM3/NIMH

ConvertaluxStarpack

Convertalux Starpack is an emergency lighting conversion kit for the conversion of 12V 20W and 50Wtungsten halogen luminaires. Assemblies utilise plug-inbattery and lamp connectors.

THSP50/NM3

• Suitable for throughhole mounting of either 65mm or 80mm• Available in two options, suitable for ceiling voids of 110mm or 220mm.• 100% rated lumen output from emergency lamps upon request. • Available with either maintenance-free sealed lead acid or Ni-Mh batteries• Ni-Mh batteries assemblies housed in a silicone coated fire retardant bag for

ease of installation.

Page 66: Ventilux Buyers Guide

Emergency Conversion Power Packs

66

The Convertalux TH Pack is a compact power pack forthe conversion of low voltage Tungsten Halogen lightingto emergency lighting operation. There is an optional100% rated lumen output from Tungsten Halogenlamps in emergency operation.

• Maintenance-free sealed lead acid batteries• Ni-Cd or Ni-Mh batteries available upon request• Compact white powder-coated galvanised steel enclosure providing an IP rating of IP22• Polycarbonate IP65 enclosure available upon request.• 75 watt and 100 watt versions available upon request.• Side and end 20mm conduit entries

Product Code Operation H W D Lamp Type BLF Battery Weight

TH20/NM3 N-M 227 325 85 12V / 20W TH 100% 12V / 14.0A/h 5.1kgTH20/M3 M 227 325 85 12V / 20W TH 100% 12V / 14.0A/h 6.0kgTH50/NM3 N-M 280 465 68 12V / 50W TH 100% 12V / 21.0A/h 10.2kgTH50/M3 M 280 465 68 12V / 50W TH 100% 12V / 21.0A/h 12.5kgTH50/NM3/C N-M 227 325 85 12V / 50W TH 10% 6V / 12.0A/h 5.1kgTH50/M3/C M 227 325 85 12V / 50W TH 10% 6V / 12.0A/h 6.0kg

Maximum cable length in metres form TH pack to luminaire

TH20/NM3 TH20/M3 TH50/NM3 TH50/M3 TH50/NM3/RO TH50/M3/RO

1.5mm2 14 14 6 6 14 142.5mm2 25 25 10 10 25 254.0mm2 36 36 16 16 36 36

* Please note if cable distance exceeds 1 metre PH120 cable has to be used as the product is deemed a central battery fitting(remote pack to lamp head)

Convertalux TH Pack

and

Page 67: Ventilux Buyers Guide

Convertalux QuickPack LED Series

Convertalux CEM Series

Emergency Conversion Power PacksBy functioning as both a mains LED driver and emergency LED driver, the QPCM4-LED conversionkit provides an environmentally friendly, long life andeconomically viable alternative to a traditional fluorescent conversion pack.

Offering light output comparable to a conventional 28watt 2D fluorescent lamp, the QPCM4-LED offers theclient an easy opportunity to significantly reduce theircarbon footprints for a relatively low initial investmentand very quick payback time.

The Convertalux CEM Series features an exceptionallylow profile conversion module designed to fit into thelatest generation of slimline luminaires. It has a combined electronic maintained version kit for 2D 28watt (4 pin) compact fluorescent lamps, providing anexcellent solution to limited space emergency light applications.

• Module size 122 x 78 x 31 mm• Ni-Mh batteries available upon request• Inverter module enclosed in white, fire retardant polycarbonate housing.• Separate switched live and permanent live supplies.• Supplied with charge indicating LED, Battery Pack and Clips.

• Conversion pack housing made from powder-coated galvanised, sheet steel • Incorporating the latest high flux CREE LED's • 50,000 hours lamp life• Emergency illuminance of 300 lumens. • Mains illuminance of 900 lumens. • Slimline conversion pack 170 mm L x 165 mm W x 50 mm H.

67

Product Code Description Range of Lamps Lamp Life

QPCM4/LED Emergency Conversion pack LED 50,000QP/LED/MAINS Mains Conversion pack LED 50,000QPCEM4/28 Emergency Conversion pack 28 Watt 2D 5,000QP/4/28/MAINS Mains Conversion pack 28 Watt 2D 5,000

Product Code Description Range of Lamps BLF

KPCEM-4-28 Inverter module, battery and charge LED 28 watt 2D 0.12CEM-4-28 Inverter module and charge LED 28 watt 2D 0.12

Page 68: Ventilux Buyers Guide

Wire Guards

68

Ventilux offer a comprehensive range of wire guards for alltheir emergency lighting products.

Wire guards provide an excellent way to protect emergencyluminaires against vandalism and accidental damage.

They offer a cost effective way of protecting the capital investment of an emergency lighting system. They are idealfor use in gymnasiums, sport halls, outdoor installations,loading areas, warehouses, schools and apartment com-plexes.

Suitable for both ceiling and wall mounted applications thewire guards are constructed from 5 mm2 galvanised steelwire with a 25 mm square opening, and offer a high levelof corrosive resistance for the most harsh environments.

Wire guards can also be custom made to individual requirements and to any specific RAL colour - please contact the Ventilux Sales department for further details.

Page 69: Ventilux Buyers Guide

69 Emer

genc

y Li

ghtin

g Sy

stem

s

Page 70: Ventilux Buyers Guide

Netcom5 XPEmergency Lighting Systems

70

WHAT IS NETCOM5 XP?Netcom5 XP is a new approach to automatic testing of emergency lightinginstallations. Compatible with both self-contained and central battery systems, it has become one of the market leaders in the field of automatedtesting of emergency lighting installations.

The testing system functions on an ethernet backbone and can be easily integrated into an existing Local Area Network (LAN).

HOW DOES NETCOM5 XP WORK?Each intelligent luminaire has at its core a stand-alone intelligent testing module (referred to as the “node”), whichtests the functionality of the luminaire before reporting back to a central control panel via a localised control module.

The node communicates with the control module via a proprietary CAN (Controller Area Network) protocol and thecontrol module communicates to the control panel via industry standard ETHERNET.

WHAT IS A NODE?The node is a stand-alone module which can be integrated into any emergency luminaire. Each intelligent luminaire has a network LED (yellow) to indicate network status and a charging LED (green) toindicate mains present and that the battery is chargingcorrectly.

The testing system functions independently and is electrically isolated from the emergency lighting installation, so there is no need for the control panelto be on-line continuously or supported by a UPS.

HOW MANY NODES CAN I HAVE ON A SYSTEM?The modular structure of the N5XP system allows thesystem to be scaled to suit any installation from 100 upto 25,300 luminaires. The modular structure also allows for simplistic later expansion of the system.

The use of the ETHERNET backbone allows fittings to be over 2000 metres away from the control panel using fibreoptic cabling and also allows for remote monitoring.

CAN I GROUP MY TESTING?The system allows for 30 independent test groups to be allocated irrespective of the physical location or the electrical circuit allocation, offering flexibility to the end user.

Page 71: Ventilux Buyers Guide

Netcom5 XPEmergency Lighting Systems

WHAT ELSE CAN NETCOM5 XP DO?With the latest interactive graphics program, the user caninterface with an AUTO-CAD floor plan to establish thehealth of their emergency lighting installation.

Site configurations are easily uploaded and downloaded, allowing ease of site set up/commissioning and troubleshooting.

WHEN WILL IT TEST THE LUMINAIRES?The default N5XP system tests the emergency installationdaily, monthly, 6 monthly and annually in accordance withcurrent legislation. A custom test regime is also available foruser settings. With the options for EMAIL and SMS texting reporting, single or multi users, AUTO-CAD graphics package - the N5XP testing systems offers a cutting edgeproduct with the added benefit of peace of mind to the client.

71

• System can monitor up to 25,300 luminaires.• Designed to function with both self contained

and central battery luminaires• Integrates into an ethernet LAN• Compliant to EN62034• Up to 253 channels available• Each channel able to run 1000 metres• User friendly software

• AUTO-CAD floor plan integration• EMAIL reporting• SMS reporting• Multi-user access over the LAN• Dial in functionality• BMS interfacing (specific to BMS protocol)• 3 year warranty as standard

KEY FEATURES:

Page 72: Ventilux Buyers Guide

ELT Central Test Unit

AC STATIC INVERTERSEmergency Lighting Systems

72

The ELT offers cost-competitive central testing, facilitating the interruption and automatic restoration of multiple circuits

• On/Off key switch to prevent unauthorised use.

• ‘Power On’ indication.

• Accurate crystal controlled timer.

• Test durations of 40 mins and 3 hours as standard.

• Alternative test durations available upon request.

• Digital display of elapsed time.

• ‘Test in Progress’ indication.

• ‘Test Completed’ indication.

• Audible warning via buzzer on commencement of final 10 minutes of test.

• Automatic restoration of supply on completion of test.

• 6, 12 and 18 way circuit Interface Units (IFU) available.

• Suitable for self-contained and central battery installations.

• Powder-coated galvanised steel enclosure as standard.

The Ventilux Emergency Lighting (VEL) series of Static Inverters are designedand manufactured in accordance with the latest European standard EN50171.

Designed to provide a Static Inverter with all the flexibility and adaptabilityyou need, these modern, compact Static Inverters have the enviable reputa-tion for consistent reliability, ease of installation and maintenance, making itideal for all emergency lighting installations.

In today’s environment, Static Inverter systems must satisfy the most challenging applications, and the versatile VEL series of Static Inverters hasall the answers with a wide choice of power ratings.

For more information about our Static Inverter Systems please contact us.

Page 73: Ventilux Buyers Guide

Desig

ners

’ Inf

orm

atio

n

73

Page 74: Ventilux Buyers Guide

74

Page 75: Ventilux Buyers Guide

Placement of LuminairesDesigners’ Information

PLACEMENT OF LUMINAIRESIS3217 and BS5266 provide detailed guidance on where luminaires shall be installed and what minimum levels of illuminanceshall be achieved on the escape routes and in open plan areas. It also specifies what the minimum period of emergency durationshall be after failure of the normal mains lighting.

DETERMINE THE POSITIONING OF EMERGENCY LIGHTING LUMINAIRESThe first priority is to determine luminaires to illuminate the “Points of Emphasis”

75

FIRE SAFETY SIGNSFire Safety Signs should comply with the requirements of the Signs Directive, unless beingused to extend an existing installation when they may be the same format as those previously installed if complying to BS5499 Pt1(UK). The viewing distance of any exit signshould be 200 times the height of the panel if internally illuminated or 100 times the heightof the panel is externally illuminated. The sign should also be positioned between 2.5 to3.0 metres from the floor to optimise viewing.

AREAS OF PARTICULAR RISKAlthough they cannot form part of the defined escape route, the following areas are also deemed necessary to have emergencylighting because of the particular risk they present.

Page 76: Ventilux Buyers Guide

Levels of IlluminanceDesigners’ Information

76

DETERMINING LEVELS OF ILLUMINANCEa) Emergency Escape Routes. For escape routes up to 2m in width, the horizontal illuminance on the floor along the centre lineof an escape route shall not be less than 1 lux and the central band consisting of not less than half the width of the route shall beilluminated to a minimum of 50% of that value.b) Open (Anti-Panic) Areas, For open areas having a floor area greater 60m2 (known as Open Plan or Anti-Panic areas) whereno fixed escape route is defined, the requirement is for a minimum of 0.5 lux anywhere on the floor, excluding 0.5m borderaround the room.c) High Risk Task Areas, High Risk Task Areas require at least 10% of the normal mains lighting level or a minimum of 15 lux, tobe provided within 0.5 seconds of failure of the supply.

LUMINAIRE SPACING DATAVerified performance data, including the maximum spacing of luminaires at particular ceiling heights is provided for all Ventiluxluminaires. The data is presented in the form of spacing tables similar to the example shown below. In addition this data is availablein DIALUX format - please contact the sales office for further details.

Luminaires on escape routes should be sited so as not to exceed the maximum spacing distances determined from the table forthe particular ceiling height. Light output from signs shall not be considered unless verified photometric data is available. Duringrisk assessment of luminaire positioning, it should be noted that luminaire performance will be adversely affected by the buildup of dirt and inadequate maintenance. Existing luminaries should be checked to ensure lamps and lighting controllers are clean,undamaged and that the lamp is not blackened.

SYSTEM CHOICEA simple comparison of the relative advantage of each type of system is shown in the following table:

Page 77: Ventilux Buyers Guide

Levels of IlluminanceDesigners’ Information

INTRODUCTION TO RISK ASSESSMENTAn Emergency Lighting Risk assessment is deemed necessary in premises where people are employed to satisfy the requirementsof the Fire Precautions Regulations. The basic risk to be assessed is that in the event of a fire there is adequate means of escape.During a fire condition, the mains lighting is likely to fail, so emergency lighting should be provided to facilitate escape.

Emergency Lighting is one of the life safety systems required to be provided, where necessary, in all places of work. The requirementfor emergency lighting, its type and location are defined through the risk assessment.

THE NEED FOR EMERGENCY LIGHTING RISK ASSESSMENTFor premises in which 6 or more persons are employed. there is a legal requirement to document and retain significant findings ofthe risk assessment and measures proposed to deal with them. If less than 5 persons are employed, there is still a requirement tocarry out a risk assessment, although it may not need to be formally recorded.

EMERGENCY LIGHTING RISK ASSESSMENTIn order to determine whether an emergency lighting installation meets the requirements of all current legislation an assessment ismade of the compliance of the installation with current standards and codes of practice. Installations of emergency lighting and signsare deemed to comply with the requirements of the Fire Precautions Regulations if installed in accordance with the governing or national standards controlling emergency lighting, for example IS3217 in Ireland and BS5266 in the UK.

REDUCING THE RISK USING ENGINEERING SOLUTIONSMany situations in premises increase the risk of fire and threaten the escape route for people in these situations. There may besimple ways to reduce that risk, for example:

77

A If the incoming mains electrical supply is not in an area of low risk, then staff may be exposed to risk from lighting failure and emergency lighting should be provided to reduce that risk.

B If the lighting final circuits do not correspond with the fire compartmentation, then the non-maintained emergency lighting may not operate when required, and maintained emergency lighting should be used to reduce that risk.

C If elderly, disabled or partially sighted people are likely to be in the building, they may obstruct the escape routes and higher emergency illuminance of at least 1 Lux* should be provided so that they can see more easily and so that others can help them escape.

D If there are potential obstructions on the escape route, then BS5266 and IS3217 advise that they should be lit in colour against a contrasting background. This contrast may not be appropriate, therefore higher emergency illuminance of at least 1 Lux* can be installed to reduce the risk due to obstructions.

E If there is likely to be a presence of high physical risk, then a further increase in emergency illuminance and a rapid response time will reduce that risk.

F If there is the possibility of arson, then intruder and fire detection and alarm systems in addition to appropriate emergency lighting will reduce that risk.

G If the length of the escape route is excessive, then the emergency lighting and signage should be assessed. Higherilluminance or repeat signage may reduce the escape time.

H If people such as the public or temporary workers unfamiliar with the layout of the building are likely to be present then high illuminance or more signs may be required.

I If the escape route passes through open areas, emergency lighting and signage should be installed.

J If an area is larger than 60m, emergency lighting and signage should be installed.

K If 5 or more people are employed in the premises, emergency lighting should be provided by an installation of fixed luminaires which are automatically switched on upon failure of normal lighting.

Page 78: Ventilux Buyers Guide

78

Page 79: Ventilux Buyers Guide

79

Page 80: Ventilux Buyers Guide

80

Page 81: Ventilux Buyers Guide

81

Page 82: Ventilux Buyers Guide

82

Page 83: Ventilux Buyers Guide

83 Serv

ice &

Mai

nten

ance

Page 84: Ventilux Buyers Guide

Service and Maintenance

84

SERVICE AND MAINTENANCEOnce you have decided to specify a Ventilux product, we want tomake sure that it gives you trouble free operation. We would bedelighted to advise you on the project design, and are available toanswer any questions throughout the commissioning period. Onceinstalled, please contact us to discuss a programme of routinemaintenance. The information below sets out procedures and responsibilities. Please call our technical helpline if you requireclarification or more details.

COMMISSIONINGVentilux offers the most comprehensive commissioning servicewithin the industry.

Ventilux ensure the system is in full working order and also in compliance with the appropriate regional or national standards.

In addition to all this we demonstrate to the end user all the functions of the system.

Ventilux have an experienced and knowledgeable team of engineers who are audited by government bodies who commis-sion all the products and systems.

MAINTENANCEVentilux Preventive Maintenance Plans offer inspection of your equipment to identify and correct potential problems before a crisisoccurs.

Government requirements place obligations on building occupiers/end user to conduct regular and routine tests and inspectionsof emergency lighting systems.

Ventilux ensure your system is in full working order and also in compliance with regional and national standards

Page 85: Ventilux Buyers Guide

Service and MaintenanceVENTILUX PROVIDE:

• Wide range of manufacturers systems supported

• Dedicated service & maintenance administration team

• Tailored invoicing to suit clients procedures

• 365 days a year service engineer response

• Experienced engineering team

• Computerised service management system

• Fully stocked vehicles

• One point of contact for all your service and testing

requirements

• Full Maintenance Report issued as required for governing

standards

Our comprehensive low-cost maintenance service plans provide coverage for any emergency or failure, with the peace of mindthat an authorised factory-trained technician will be on site to address your problem within a matter of hours.

Our multi-skilled technicians carry out a detailed analysis of system requirements and prepare programmes of regular checksthat help reduce service costs, ensure the value of the product and most importantly ensuring you have emergency lighting coverage in your building when most required.

85

PLEASE CONTACT VENTILUX DIRECTLY FOR FURTHER DETAILS.

VENTILUX LIMITEDUnit 2, Ashgrove Industrial EstateKill Avenue, Dun LaoghaireCo. Dublin, Ireland.Tel: (Int) +353 (0) 1 214 8800Fax: (Int) +353 (0) 1 280 5729Email: [email protected]

VENTILUX UK LIMITEDUnit 20 Britonwood trading Estate,Faraday Road, Knowsley Business Park, Kirkby,Merseyside L33 7UT, UKTel: (Int) +44 (0) 151 546 4155Fax: (Int) +44 (0) 151 546 3987Email: [email protected]

T H E E M E R G E N C Y L I G H T I N G S P E C I A L I S T S

www.ventilux.com

Page 86: Ventilux Buyers Guide

Glossary

86

A/h: Amp per hour

Anti-Panic (Open) Area Lighting: The part of Emergency Escape Lighting provided to avoid panic and provide illumination allowingpeople to reach a place where an escape route can be identified.

Ballast: The component that controls the operation of a lamp from a specified low or high voltage AC or DC source.

Ballast Lumen Factor: The ratio of the light output of the lamp in emergency operation compared with the light output of thesame lamp operated by a reference ballast at its rated voltage andfrequency.

CE Marked: With the CE marking on a product, the manufacturer declares that the product conforms with the essential requirementsof the applicable EC directives

Central Battery System: A system in which the batteries for a number of emergency luminaires are housed in one location.Usually for all the emergency luminaires on one lighting sub-circuit, butsometimes for all emergency luminaires in a complete building.

CREE LED: Cree is a market-leading innovator of lighting-class LEDs, LED lighting, and semiconductor solutions for wireless andpower applications.

DALI: Digital Addressable Lighting Interface

Duration: The period of time, in hours, that the luminaire can maintain continuously the minium level of illuminance required.

EMC compliant: Electric Magnetic Compatibility

Emergency Exit: The way out of a building, which is intended to be used at any time whilst the premises is occupied.

Escape Route Lighting: Lighting provided to ensure that the means of escape to the final EXIT point can be effectively identifiedand safely used.

Emergency Lighting: The lighting provided for use when the supply to the normal mains lighting installation fails.

Exit Luminaire: An emergency luminaire designed to serve as an Exit sign.

‘F’ Mark: Mark indicating that a luminaire is suitable for mounting onto normally combustible surfaces.

Glow Wire Test: The glow-wire test (850°c) is one of the most important fire-related tests for plastics used in the electrical industryand simulates overheating of wires or components such as resistors or capacitors.

ICEL: Industry Committee Emergency Lighting

Ingress Protection (IP) Number: Classification of the degree of protection a luminaire provides against the entry of solid foreignbodies and moisture

ISO:9001:2008: The ISO 9000 family of standards is related to quality management systems and designed to help organisationsensure that they meet the needs of customers and other stakeholders while meeting statutory and regulatory requirements relatedto the product.

Page 87: Ventilux Buyers Guide

GlossaryLED: Light Emitting Diode

LIF: Lighting Industry Foundation

Lumens: The lumen is the unit of luminous flux, a measure of the total "amount" of visible light emitted by a source.

Luminaire: Apparatus which distribute the light given by a lamp or lamps, including all of the items necessary for fixing and protecting the lamps and for connecting them to the electrical supply.

Ni-Cd: Nickel Cadmium Battery

Ni-Mh: Nickel Metal Hydride

Non-Maintained Emergency Luminaire: A luminaire containing one or more lamps, which operate from the emergency supplyonly upon failure of the normal mains supply.

Maintained Emergency Luminaire: A luminaire containing one or more lamps, all of which operate from the normal supply orfrom the emergency supply at all material times.

Mounting Height: The vertical distance between the underside of the luminaire or base of a sign and the working plane. Note: Foremergency lighting the floor is always taken to be the working plane.

NSAI: National Standard Authority of Ireland

Photometric Data: Photometric Data is often used to simulate lighting designs for projects before they are built or renovated. Thisenables architects, lighting designers, and engineers to determine whether a proposed lighting setup will deliver the amount oflight intended. They will also be able to determine the contrast ratio between light and dark areas.

Self Contained Emergency Luminaire: A luminaire or sign providing Maintained or Non-Maintained emergency lighting, in whichall the elements such as battery, the lamp and the control unit are contained within the housing or within 1 metre of the housing.

Slave Luminaire: An emergency luminaire without its own batteries, which is designed to work inconjunction with a central battery system.

Combined/Sustained Emergency Luminaire: A luminaire containing two or more lamps, at least one of which is energised fromthe emergency supply and the remainder from the normal supply

VA: Volt-ampere (VA) is a measurement of power in a direct current ( DC ) electrical circuit.

87

DISCLAIMERWhile every care has been taken to ensure accuracy in the production of this ‘Buyer’s Guide’ we take no responsibility for any errors or omissions. E & OE.

© VENTILUX LIMITED

Page 88: Ventilux Buyers Guide

88

DOWNLIGHTS/ PL TYPE FITTINGS VENTILUX IN-HOUSE CONVERSION VENTILUX CONVERSION KITS5/7/9WPLS DOWNLIGHT OR BULKHEAD FPHFM3/18/R KPHFM3/18/R11WPLS FPHFM4/58/R KPHFM4/58/R18WPLL FPHFM3/18 KPHFM3/1824WPLL FPHFM4/58/R KPHFM4/58/R36WPLL FPHFM4/58 KPHFM4/5840WPLL FPHFM4/28 KPHFM4/2855WPLL ZFPHFM655 KPHFM65580WPLL FPMAC6/80 (SLIMLINE BOARD) KPMAC6/80 (SLIMLINE BOARD)10W PL-C/PL-T/TC-D/TC-T FPHFM3/18/R KPHFM3/18/R13W PL-C/PL-T/TC-D/TC-T FPHFM4/58/R KPHFM4/58/R18W PL-C/PL-T/TC-D/TC-T FPHFM4/58/R KPHFM4/58/R26W PL-C/TC-D FPHFM4/58/R KPHFM4/58/R26W PL-T/TC-T FPHFM6/42/R KPHFM6/42/R32W PL-T/TC-T FPHFM6/42/R KPHFM6/42/R42W PL-T/TC-T FPHFM6/42/R KPHFM6/42/R57W PL-T/TC-T FPHFM6/42/R KPHFM6/42/RT5 MODULARS/CORROSSION PROOFS/BATTENS VENTILUX IN-HOUSE CONVERSION VENTILUX CONVERSION KITS14WT5/T16 FPHFM4/14/T5 KPHFM4/14/T521WT5/T16 FPHFM4/14/T5 KPHFM4/14/T524WT5/T16 FPHFM4/24/T5 KPHFM4/24/T528WT5/T16 FPHFM6/28/T5 KPHFM6/28/T535WT5/T16 FPHFM6/35/T5 KPHFM6/35/T539WT5/T16 FPHFM6/39/T5 KPHFM6/39/T549WT5/T16 FPHFM6/49/T5 KPHFM6/49/T554WT5/T16 FPHFM6/54/T5 KPHFM6/54/T555WT5 (CIRCULAR) FPHFM6/60/R KPHFM6/60/R80WT5/T16 FPHFM6/80/T5 KPHFM6/80/T5MODULARS/CORROSSION PROOFS/BATTENS VENTILUX IN-HOUSE CONVERSION VENTILUX CONVERSION KITS18W T8/T26 FPHFM3/18 KPHFM3/1830W T8/T26 FPHFM4/58 KPHFM4/5836W T8/T26 FPHFM4/58 KPHFM4/5858W T8/T26 FPHFM4/58 KPHFM4/5870W T8/T26 FPHFM5/70 KPHFM5/702D CIRCULARS/SQUARES VENTILUX IN-HOUSE CONVERSION VENTILUX CONVERSION KITS16W2D FPH-4-16 KPH-4-1621W2D FPHFM4/28/R KPHFM4/28/R28W2D FPNCEM4/28 KPNCEM4/2838W2D FPHFM5/38/R KPHFM5/38/R55W2D FPH6/42/R (SLIMLINE GEAR) KPH6/42/R (SLIMLINE GEAR)LOW VOLTAGE VENTILUX IN-HOUSE CONVERSION VENTILUX CONVERSION KITS12V 20W HALOGEN FPTH20/NM3 KPTH20/NM312V 35W HALOGEN FPTH50/M3 KPTH50/M312V 50W HALOGEN FPTH50/M3 KPTH50/M312V 75W HALOGEN FPTH100/NM or M3 KPTH100/NM or M312V 100W HALOGEN FPTH100/NM or M3 KPTH100/NM or M3

Ventilux Conversion Codes

Page 89: Ventilux Buyers Guide

BATTERIES VENTILUX PART CODE Ni-CAD STICKS

2 CELL Ni-CAD STICK 702233 CELL Ni-CAD STICK 701704 CELL Ni-CAD STICK 701235 CELL Ni-CAD STICK 701256 CELL Ni-CAD STICK 70128

Ni-CAD PACKS2 CELL Ni-CAD PACK 702303 CELL Ni-CAD PACK 701224 CELL Ni-CAD PACK 701845 CELL Ni-CAD PACK 701016 CELL Ni-CAD PACK Z17468 CELL Ni-CAD PACK 7013410 CELL Ni-CAD PACK 70129

Ni-MH STICKS2 CELL Ni-MH STICK 702313 CELL Ni-MH STICK 702324 CELL Ni-MH STICK 702335 CELL Ni-MH STICK 702346 CELL Ni-MH STICK 70235

NI-MH PACKS2 CELL Ni-MH PACK PLEASE ASK SALES3 CELL Ni-MH PACK PLEASE ASK SALES4 CELL Ni-MH PACK PLEASE ASK SALES5 CELL Ni-MH PACK 702376 CELL Ni-MH PACK 70236

SEALED LEAD ACID (SLA)6V 12AH 7013312V 2.1AH 7021612V 2.8AH 7022012V 7AH 701626V 2.8AH 70114

ACCESSORIES VENTILUX PART CODE28W 2D BALLAST 90110GREEN CHARGER LED (1METRE) 10520CEM BALLAST/MODULE 28W2D (Combined Electronic) 7011628W 2D LAMP 202358 WATT LAMP 2012412V 21 WATT LAMP Z1815

EMERGENCY MODULES VENTILUX PART CODEHFM3/18 13016HFM3/36 13015HFM4/14 13017HFM4/28 13017HFM4/58 13014HFM5/38 00102HFM5/70 00105MOHFM6/28 13043HFM6/35 13043HFM6/42 13028HFM6/49 13044HFM6/54 13044HFM6/80 13044HFM6/55 13042

89

Ventilux PartsVentilux Parts

Page 90: Ventilux Buyers Guide

90

NotesNotes

Page 91: Ventilux Buyers Guide

91

NotesNotes

Page 92: Ventilux Buyers Guide

92

NotesNotes

Page 93: Ventilux Buyers Guide

93

NotesNotes

Page 94: Ventilux Buyers Guide

94

NotesNotes

Page 95: Ventilux Buyers Guide

WP BulkheadEscape Route

The robust and durable design of the (IP65) WP Bulkhead Luminaire makes it ideal for a range of exterior and selected interior locations. Operators ofleisure centres, car parks, sports facilities, factories andunderground walkways will benefit from its tough, vandal resistant construction and ease of installation.

The WP range includes a flame retardant ABS body andincludes an Opal diffuser as standard.

The luminaires in the WP range are available either foremergency lighting or mains illumination and conformfully with European Standards.

Specify /MFR for internal mains failure hold off relayM denotes Maintained, N-M denotes Non-MaintainedSpecify 24 / 50 / 110 / 230 Volts AC/DC System VoltageFor other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration

• Dimensions: 368 x 150 x 102 (mm)• Opal diffuser as standard, Prismatic diffuser also available• White finish as standard • Available in chrome/CH, brass/BR and other colours on request• Sticker legends (page ?)• Also available with NETCOM 5XP or DALI addressable• Available with auto test / push test function

Product Code Mode of Lamp Battery Lumen VA Weightoperation

Escape RouteWPM3/F8 M T5-8 Watt 2.4V/4.5A/h 78 TBC 1.9kgWPNM3/F8 N-M T5-8 Watt 2.4V/4.5A/h 87 1.6kgWPS3/F8 Sustained T5-8 Watt 2.4V/4.5A/h 87 1.8kgWPM3/LED/1W M 1 Watt LED 4.8V/1.3A/h TBC TBCWPNM3/LED/1W N-M 1 Watt LED 4.8V/1.3A/h TBC TBCWPM3/LED/3W M 3 Watt LED 4.8V/1.3A/h TBC TBCWPNM3/LED/3W N-M 3 Watt LED 4.8V/1.3A/h TBC TBC

Exit SignageWPM3/F8/EXIT M T5-8 Watt 2.4V/4.5A/h N/A TBCWPNM3/F8/EXIT N-M T5-8 Watt 2.4V/4.5A/h N/A TBCWPM3/LED/EXIT M 1 Watt LED 4.8V/1.3A/h N/A TBCWPNM3/LED/EXIT N-M 1 Watt LED 4.8V/1.3A/h N/A TBC

View From 22M

Fire Protection Equipment

Ventilux is a full-service Fire Protection supplier that has built a solid reputationbased on our commitment to provide only the highest quality products and outstanding service.

We provide an extensive line of fire protection equipment which include:

· Fire Panels· Break Glass Units· Smoke Detectors· Heat Detectors· Bells· Sounders· Door Retainers

Ventilux has a full extensive range that is certified to national standards.

Ventilux can also fully service and commission fire safety panels and systems to give complete customer peace of mind.

Our staff are committed to exceptional customer service and rapid delivery to exceed your expectations.

If you have a need for fire protection equipment call us today!

95

Page 96: Ventilux Buyers Guide

TH E E M E RG E NC Y L IG HTI NG S P EC IAL I STS

W W W.VE NTI LUX .COM

DI STR I B UTE D BY :