velux.co.uk/modularskylightsVersion 3.1
VELUX Modular SkylightsTechnical Handbook
2 3VELUX
Introduction
VELUX modular skylights are sash-frame constructed single skylights with a high-insulating glazing unit. The modules are available as fixed and venting skylights. All individual skylights are delivered as prefabricated modules with dedicated factory finished flashings to ensure superior watertightness in every available solution.
VELUX modular skylights are CE-marked in accordance with the harmonized standard EN 14351-1:2006+A1:2010 Windows and doors.
In addition the skylight modules have been tested and approved in accordance to EN 12101-2:2003 - Smoke and heat control systems Part 2: Specification for natural smoke and heat exhaust ventila-tors. This means that VELUX modular skylights with ventilation capabilities may also be used as Natural Smoke and Heat Exhaust Ventilators (NSHEV).
This technical handbook for VELUX modular skylights describes the product characteristics and performance of the skylight module together with sunscreening and control system. For real life case studies and inspiration, please refer to velux.co.uk/modularskylights
VELUX Modular Skylights
4 5VELUX
81
Shaped Solution with Adaption of Lining 82Shaped Solution with Adaption of Skylight Modules 82Shaped Solutions with Oval Lining Do and Donts 8 3Asymmetric Ridgelight 84Longlight Step Solution 84Atrium Combined Solutions 85Infill Panel 85Ridgelights with Glass Gables 86Skylight Modules with Photovoltaic Glasing Units 86Light Fittings on Modules 87
Tips and tricks
Index
89
Product Label 90Modular Skylights 90Modular Flashings 91Roller Blinds 91
Product codes
7Modular System
Skylight Module 8Functions & Sizes 8Solutions 10Module Main Components 12Module Electrical Components 13Frame & Sash 14Cladding & Flashing 17Glazing Unit 18Brackets & Hinges 20Module - Assembled 22Vapour Barrier Connection Strip 24 Chain Actuator 25Control System 26 Roller Blind 27Beam for Ridgelight at 5 28Type Sign 29
31Solutions
Quick Overview of Skylight Solutions vs. Roof Constructions 32Longlight 5 - 25 34Wall-mounted Longlight 5 - 40 36Northlight 40 - 90 38Ridgelight 25 - 40 40Ridgelight at 5 with Beam 42Atrium Longlight 44 Atrium Ridgelight and Atrium Ridgelight at 5 with Beam 46
NSHEV ( Natural Heat and Smoke Exhaust Ventilators) - EN 12101-2:2003
Geometric area EN 12101-2:2003 Av [m2] 0,48 -1,89 depending on size
Aerodynamic area EN 12101-2:2003 Annex B Aa Roof [m2] 0,05-0,89 depending on size
Aerodynamic value EN 12101-2:2003 Annex B Cv0 0,08 - 0,52 depending on size
Snow load (SL) EN 12101-2:2003 Annex E SL [N/m2] 750 N/m2
Wind load (WL) EN 12101-2:2003 Annex F WL [N/m2] 3000 N/m2
Low ambient temperature (T) EN 12101-2:2003 Annex E T [C] T (-15)
Reliability (RE) ( Dual purpose) EN 12101-2:2003 Annex C RE [Nr of opening] 1000 + 10000
Resistance to heat (B) EN 12101-2:2003 Annex G B [C] B300
Reaction to fire for NSHEV EN 13501-1 Class B-s1,d2 for IGU 55.2B-s1,d0 for IGU 33.2
49Product Data
Skylight Module 50Glazing Area 57Frame & Sash 57Cladding & Flashing 57Glazing Unit 58Vapour Barrier Connection Strip 60Chain Actuator 60Control System 62Roller Blind 63 Beam for Ridgelight at 5 67Resistance to Wind Load 68Reaction to Fire 70Resistance to Fire 72External Fire Performance 74Watertightness 76Air Permeability 78
6 7VELUX
Modular System
8 9VELUX
HFC Fixed skylight module
VELUX modular skylights are available as fixed and venting mod-ules. Due to a hidden chain actuator, the fixed and venting skylight modules appear to be visually identical in closed position.
Venting modules are top-hung and can be used for comfort ventilation, and in addition, a number of sizes are also approved for smoke ventilation according to NSHEV EN 12101-2:2003.
Functions & Sizes
HVC Motorized comfort venting skylight moduleOpening up to 410 mm
HVC Motorized smoke venting skylight moduleOpening up to 700 mm in less than 60 seconds
CE marked VELUX modular skylights can be used in any building where the national, local and individual building requirements allow the use of skylight modules. Given the aesthetics and advanced per-formance of the products, VELUX modular skylights are commonly used in heated buildings and primarily in projects that support light
commercial interests, e.g. hospitals, schools, shopping centres, of-fices, museums etc. However all buildings that have a suitable struc-ture, and which are large enough to host an installation, will support VELUX modular skylights.
Skylight Module Size grid
Modular System
How to measure the modules
Width and height of the modules are determined by the exterior W and H dimensions of the frame not the measurements of the cladding, flashing or brackets.
H
W
H: Height
W: Width
Fixed modules Comfort ventilation Smoke ventilation
mm 675 750 800 900 1000
80
010
00
120
014
00
160
018
00
200
022
00
240
026
00
280
030
00
mm 675 750 800 900 1000
80
010
00
120
014
00
160
018
00
200
022
00
240
0
Please refer to our Technical Handbook for size specific load capabilities.
If roller blinds are requested for smoke venting modules, please refer to local fire authorities for permission.
mm 675 750 800 900 1000
80
010
00
120
014
00
160
018
00
200
022
00
240
0
No roller blinds available.
Modules for longlight and northlight, with extra strong glazing unit.*
****
****
*
*
*****
Standard size. Special sizes, functional limitations may apply.
10 11VELUX
Longlight 5 - 25 Page: 34
Page: 38
Page: 40
Page: 46Page: 44
Page: 42
Page: 46
Page: 36
Northlight 40 - 90 Atrium Ridgelight 25 - 40Atrium Longlight 5 - 25
Ridgelight 25 - 40Wall-mounted Longlight 5 - 40
Atrium Ridgelight at 5 with Beam
Ridgelight at 5 with Beam
Solutions
Modular System
VELUX modular skylights can be combined in a number of configu-rations creating perfect solutions for a wide variety of building types, from narrow corridors and internal courts to studios and
large circulation spaces. Each solution is delivered with a special designed, prefabricated flashing ensuring perfect system fit and 100% water tightness.
12 13VELUX
Module Main Components
Mounting bracket
Cladding
Flashing
Flashing
Chain actuatorFrame and sash
Glazing unit
Roller blind
Remote control
Module Electrical Components
Modular System
Power supply and control unit
Read more about electrical products in Electrical Hand-book at: velux.co.uk/modularskylights
!
velux.co.uk/modularskylightsVersion 2.0
VELUX Modular SkylightsElectrical Handbook
Remote control Power supply and control unit
Rain and wind sensor unit
Wall switch Interface for external wall switch
Interface for external control devices
KLR 200 KLR 200 KLA S105 KLI 110 KLF 050 KLF 100
14 15VELUX
The main structural profiles of VELUX modular skylights consist of pultruded composite, containing approximately 80% continuous fi-breglass treads and 20% two-component polyurethane resin.
The composite guarantees high heat insulating performance (graph 1) and thermal stability (graph 2) as well as excellent profile shifti-ness (graph 3) and strength (graph 4). In combination, the charac-teristics of the VELUX composite gives the slim profiles self-suppor- ting strength and an ability to support installations of considerable
size. In addition the material is maintenance-free, non-corrosive and electrical non-conductive.
In combination with low-energy glazing units the VELUX modular skylights are able to achieve one of the lowest overall U-values for frame and glazing assembly within the skylight market. The inner surface is treated with white paint as standard. Other colours are available to special order.
Frame & Sash Frame & Sash
Modular System
Thermal conductivity (W/mk) A low score means high insulation performance
A low score means high thermal stability
Profiles used for VELUX modular skylights consist of an extremely low-conductive pultruded fibreglass and polyurethane composite resulting in high insulation performance.
1
Linear expansion coefficient (10-6 m/m K)
Whereas traditional skylight materials are bound to fluctuations in form due to thermal changes, the compos-ite of VELUX modular skylights will maintain its dimen-sional properties, ensuring tightness of joints and pro-longing the expected lifetime of the application.
2
Source: 1) Accredited external tests 2) According to EN ISO 10077-2 3) Value identical to fibreglass 4) www.engineeringtoolbox.com 5) Internal VELUX testFrame and sash for venting skylight moduleFrame for fixed skylight module
Frame and sash assembled
HFC HVC
40
45
50
5
10
15
20
25
30
35
VELUX composite
Aluminium Pine wood PVC
5.0 4)
22.2 4)
6.0 3)
50.4 4)
0.3 1)
0.12-0.18 2)
1.7 2)
140
150
160
1
0,5
90
100
110
120
130