Click here to load reader
View
9
Download
0
Embed Size (px)
thermoscientific
Vanquish
Variable Wavelength Detectors VC-D40, VF-D40
Operating Manual 4820.7701-EN Revision 2.0 • December 2019
Copyright © 2019 Thermo Fisher Scientific Inc. All rights reserved.
Original Operating Manual
The hardware descriptions in this manual revision refer to devices VC-D40-A, VF-D40-A.
Trademarks
Acrobat, Adobe, and Adobe Reader are trademarks of Adobe Systems Incorporated. Microsoft and Windows are trademarks of Microsoft Corporation. MP35N is a trademark of SPS Technologies. Torx is a trademark of Acument Intellectual Properties, LLC. All other trademarks are property of Thermo Fisher Scientific and its subsidiaries.
Disclaimer
Thermo Fisher Scientific Inc. provides this document to its customers with a product purchase to use in the product operation. The document is copyright protected; any reproduction of the whole or any part of this document is strictly prohibited, except with the written authorization of Thermo Fisher Scientific Inc.
This manual is provided "as is." The contents of this manual are subject to being changed, without notice, in future revisions.
Thermo Fisher Scientific Inc. makes no representations that this document is complete, accurate, or error-free. Thermo Fisher Scientific Inc. assumes no responsibility and will not be liable for any errors, omissions, damage, or loss that might result from any use of this document, even if the information in the document is followed properly.
This document is not part of any sales contract between Thermo Fisher Scientific Inc. and a purchaser. This document shall in no way govern or modify any Terms and Conditions of Sale. The Terms and Conditions of Sale shall govern all conflicting information between the two documents.
Printed manual version only
Printed in Germany on 100% chlorine-free bleached, high-white paper that is produced in an environmentally friendly process, leading to a paper profile of zero CO2 emissions.
Manufacturer's address
Dionex Softron GmbH, Part of Thermo Fisher Scientific, Dornierstrasse 4, D-82110 Germering
Contacting Us There are several ways to contact us:
Ordering Information
For ordering information or sales support for HPLC products, contact your local Thermo Fisher Scientific sales organization. For contact information, go to Contact Us on http://www.thermofisher.com.
Technical Assistance
For technical support for HPLC products, contact your local Thermo Fisher Scientific support organization. For contact information, go to Contact Us on http://www.thermofisher.com.
Contacting Us
Variable Wavelength Detectors (VC-D40, VF-D40) Operating Manual
Page 3
http://www.thermofisher.com http://www.thermofisher.com
Contacting Us
Page 4 Variable Wavelength Detectors (VC-D40, VF-D40) Operating Manual
Contents
Variable Wavelength Detectors (VC-D40, VF-D40) Operating Manual
Page 5
Contents 1 Using this Manual ...................................................................... 11
1.1 About this Manual ................................................................................................ 12
1.2 Conventions.......................................................................................................... 13 1.2.1 Safety Messages....................................................................................... 13 1.2.2 Special Notices and Informational Notes ................................................. 13 1.2.3 Typographical Conventions ...................................................................... 14
1.3 Reference Documentation ................................................................................... 15
2 Safety......................................................................................... 17 2.1 Safety Symbols and Signal Words......................................................................... 18
2.1.1 Safety Symbols and Signal Words in This Manual .................................... 18 2.1.2 Observing this Manual ............................................................................. 18 2.1.3 Safety Symbols on the Device .................................................................. 19 2.1.4 Rating Plate .............................................................................................. 19
2.2 Intended Use ........................................................................................................ 20
2.3 Safety Precautions................................................................................................ 21 2.3.1 General Safety Information...................................................................... 21 2.3.2 Qualification of the Personnel ................................................................. 21 2.3.3 Personal Protective Equipment................................................................ 22 2.3.4 Electrical Safety Precautions .................................................................... 23 2.3.5 General Residual Hazards......................................................................... 23 2.3.6 In Case of Emergency ............................................................................... 26
2.4 Solvent and Additive Information ........................................................................ 27 2.4.1 General Compatibility .............................................................................. 27 2.4.2 Allowed pH Ranges................................................................................... 28 2.4.3 Allowed Concentrations ........................................................................... 28 2.4.4 Further Information ................................................................................. 29
2.5 Compliance Information....................................................................................... 30
3 Device Overview ........................................................................ 31 3.1 Detector Features................................................................................................. 32
3.2 Operating Principle............................................................................................... 33
3.3 Interior Components ............................................................................................ 35
3.4 Flow Cell ............................................................................................................... 36
3.5 Lamps ................................................................................................................... 38
Contents
Page 6 Variable Wavelength Detectors (VC-D40, VF-D40) Operating Manual
3.6 Leak Detection...................................................................................................... 39
3.7 Operation ............................................................................................................. 40
4 Unpacking .................................................................................. 41 4.1 Unpacking............................................................................................................. 42
4.2 Scope of Delivery.................................................................................................. 44
5 Installation................................................................................. 45 5.1 Safety Guidelines for Installation ......................................................................... 46
5.2 Installing the Device ............................................................................................. 47
5.3 Site Requirements ................................................................................................ 49 5.3.1 Power Considerations .............................................................................. 49 5.3.2 Power Cord............................................................................................... 49 5.3.3 Condensation ........................................................................................... 50
5.4 Accessing the Interior Components ..................................................................... 51
5.5 Setting Up the Hardware...................................................................................... 52 5.5.1 System Arrangement................................................................................ 52 5.5.2 Connecting the Device ............................................................................. 53 5.5.3 Connecting the Power Cord ..................................................................... 55
5.6 Installing a VIS Lamp (Tungsten Lamp) (Optional)................................................ 56
5.7 Installing a Flow Cell ............................................................................................. 59 5.7.1 Removing the Diagnostic Cell................................................................... 59 5.7.2 Installing a Flow Cell without Connection Unit ........................................ 60 5.7.3 Installing a Flow Cell with Connection Unit.............................................. 60
5.8 Setting Up the Flow Connections ......................................................................... 62 5.8.1 General Information and Guidelines........................................................ 62 5.8.2 Guiding Capillaries an