17
V200 POSITIONER www.vacaccessories.com 92076r14 1

V200 POSITIONER - Valve Accessories & Controls, INCvacaccessories.com/wp-content/uploads/2017/08/92076r14-V200... · V200 POSITIONER ... cess water will eventually reach the control

Embed Size (px)

Citation preview

Page 1: V200 POSITIONER - Valve Accessories & Controls, INCvacaccessories.com/wp-content/uploads/2017/08/92076r14-V200... · V200 POSITIONER ... cess water will eventually reach the control

V200 POSITIONERwww.vacaccessories.com

92076r14 1

Page 2: V200 POSITIONER - Valve Accessories & Controls, INCvacaccessories.com/wp-content/uploads/2017/08/92076r14-V200... · V200 POSITIONER ... cess water will eventually reach the control
Page 3: V200 POSITIONER - Valve Accessories & Controls, INCvacaccessories.com/wp-content/uploads/2017/08/92076r14-V200... · V200 POSITIONER ... cess water will eventually reach the control

V200 POSITIONERwww.vacaccessories.com

92076r14 3

1 INTRODUCTION .................................................................................. 4 1.1 Air quality recommendations ................................................... 4 1.2 Safety Instructions ................................................................... 42 INSTALLATION .................................................................................... 5 2.1 Installing external IP converter on V200P ........................... 5 2.2 Installing external IP converter on V200E ............................... 6 2.3 MainsupplyfilterforIPconverter ............................................ 73 SPARE PARTS ................................................................................... 8 3.1 Exploded drawing external options ......................................... 8 3.2 Spare parts list external options .............................................. 94 SPECIFICATIONS............................................................................... 10 4.1 Specificationsexternaloptions ................................................ 105 DIMENSIONS ...................................................................................... 11 5.1 V200 E 0-10V .......................................................................... 11 5.2 V200 EX ................................................................................. 12 5.3 V200 EX-GA ............................................................................ 13 5.4 V200 FF .................................................................................. 14

CONTENTS

Page 4: V200 POSITIONER - Valve Accessories & Controls, INCvacaccessories.com/wp-content/uploads/2017/08/92076r14-V200... · V200 POSITIONER ... cess water will eventually reach the control

V200 POSITIONERwww.vac.se

92076r144

1.1 Air quality recommendations

Poor air quality is one of the main causes of premature functional problems with pneumatic and electropneumatic equipment. The pilot valve and IP converter are precision instru-ments, and are therefore the most sensitive parts of the positioner.

a) Water in the supply air is a natural occur-rence. This happens when air is compressed. The compression heats the air and the natural degree of water in the air can remain as mois-ture. When the air cools in pipes etc. the moisture condenses and becomes liquid water. Large quantities can build and some-timesfloodsmallwaterseparators.Thisex-cess water will eventually reach the control valve and positioner. This can cause corrosion damage to the IP converter, causing the unit to malfunction.

We strongly recommend the use of water separators with adequate capacity. Coales-ingfiltersfromareputablemanufacturerisaninexpensive way to help prevent unit malfunc-tions or failures, and add life to the product. Thesefiltersremoveparticlesandmoisturefrom air lines.

b) Oil in the supply air usually is from the main compressor. Oil can clog the small nozzles anddisturbtheflapperintheIPconverter.Itcan also cause the spool to “drag” within the pilot valve. The result is poor control or in the worst case, failure.

c) Particles in the air usually occur because of corrosion. Dirt and particles can block the small nozzles of the IP converter. They can also cause the pilot valve to mal-function. The unit may completely fail.

To ensure normal operational safety with VAC positioner products, we recommend that a wa-terseparatoranda<80micrometerfilteraremounted as close to the product as possible.If large amounts of oil are present an oil sepa-rator should be installed as well.

To further increase operational safety, we rec-ommend that the working air is clean, dry and free of moisture, water, oil, particles and other contaminants, in accordance with the Standard ANSI/ISA– 7.0.01– 1996

CAUTION: Beware of moving parts when positioner is operated!

CAUTION: Beware of parts with live voltage! A voltage, which is normally not dangerous, is supplied to the positioner. Avoid touching live parts and bare wires as well as short circuiting live parts and the housing.

CAUTION: Do not dismantle a pressurized positioner! Dismantling a pressurized positioner will result in uncontrolled pressure release. Always isolate the relevant part of the pipeline. Release the pres- sure from the positioner and the pip- ing. Failure to do this may result in damage or personal injury.

CAUTION: Do not exceed the positioner performance limitations! Exceeding the limitations marked on the positioner may cause damage to the positioner, actuator and valve. Damage or personal injury may result.

1.2 Safety Instructions

1 INTRODUCTION

Page 5: V200 POSITIONER - Valve Accessories & Controls, INCvacaccessories.com/wp-content/uploads/2017/08/92076r14-V200... · V200 POSITIONER ... cess water will eventually reach the control

V200 POSITIONERwww.vacaccessories.com

92076r14 5

Positioner.eps

Exte

rnal

IP in

stal

latio

n.ep

s

2 INSTALLATION

1

3

2

45

12

6

2.1 Installing external IP converter on V200P

NOTE! This instruction is for use when converting from V200P to V200EX, V200FF or other external IP converter. When converting from V200E please follow the instruction in section 2.2.

1. Loosen the screw (1) and remove the plate(2).

2. Make sure there are three O-rings(3) in the positioner housing.

3. Install the IP converter(4) and tighten the screws(5).

4. Install the 1/4” plug(6) in the port marked I.

1 - External IPs are pre-calibrated to supply the V200 positioner with the proper pneumaticinput signal, relative to electronic input.NO CALIBRATION of the external IP is needed

2 - All External IPs are supplied air from the V200 supply port. This internal porting pro-vides the proper air supply to the external IP.NO ADDITIONAL AIR PORTING OF THE IP IS NEEDED

5

Page 6: V200 POSITIONER - Valve Accessories & Controls, INCvacaccessories.com/wp-content/uploads/2017/08/92076r14-V200... · V200 POSITIONER ... cess water will eventually reach the control

V200 POSITIONERwww.vac.se

92076r146

IP s

crew

s.ep

s

4

2

1

5

3

2.2 Installing external IP converter on V200E (which has the internal IP inside the unit).

1. Loosen the two screws(1) that secure the internal IP converter(2) and remove the internal IP.

2. Make sure the two O-rings(3) are still in the positioner housing.

3. Install the pneumatic sealing plate(4) and tighten the screws.

4. Check that the 1/4”plug(5) is installed in the port marked I.

5. Continue with the instruction 2.1 (page 5)

Page 7: V200 POSITIONER - Valve Accessories & Controls, INCvacaccessories.com/wp-content/uploads/2017/08/92076r14-V200... · V200 POSITIONER ... cess water will eventually reach the control

V200 POSITIONERwww.vacaccessories.com

92076r14 7

1

2

3 4

2

2.3 Main supply filter for IP converter

Changing the filter

1. Turnoffordisconnectthemainairsupply. Should air supply not be disconnected or turnedoff,thepressuremaycausethe filtercovertoejectfromtheunit.

2. Loosenthescrew(1)andremovefilter cover(2)

3. Cautiouslyremovethefilter(3)witha sharp pointed object e.g. a pocket knife.

4. Pressthenewfilter(3)intothehousing.

5. Check the O-ring(4) and replace if needed.

5. Installthefiltercover(2)andtightenthe screw(1)

If the filter(3) shows traces of oil or water, check the water/oil separator in the supply line. Oil and water can cause functional problems in the IP converter.

Page 8: V200 POSITIONER - Valve Accessories & Controls, INCvacaccessories.com/wp-content/uploads/2017/08/92076r14-V200... · V200 POSITIONER ... cess water will eventually reach the control

V200 POSITIONERwww.vac.se

92076r148

3.1 Exploded drawing external options

3 SPARE PARTS

Page 9: V200 POSITIONER - Valve Accessories & Controls, INCvacaccessories.com/wp-content/uploads/2017/08/92076r14-V200... · V200 POSITIONER ... cess water will eventually reach the control

V200 POSITIONERwww.vacaccessories.com

92076r14 9

3.2 Spare parts list external options

Item Description Material Part no Qty1 .......External IP module 0-10V .............................................93064 .............. 1 1 ...... IP 0-10V ........................................................................Contact VAC ... 1 2 ......Mounting Kit external IP FA TA78+TA61 ......................91024 .............. 1 ....... - Screw ISO 7048 M5x20/12 ..Stainless Steel ..............7048052012 .... 1 ....... - Screw ISO 7048 M5x16/10 ..Stainless Steel ..............7048051610 .... 1 ....... - Screw #8-32 UNC 13 x 13 ...Stainless Steel ..............476208321313 3 ....... - Rubber Gasket IP TA78+TA61Nitrile Rubber ..............90142 .............. 1 ....... - Mounting Plate FA TA78 +TA61Aluminum, painted ....90085 .............. 1

2 .......External IP Module EX ..................................................93017 .............. 1 1 ...... IP EX .............................................................................Contact VAC ... 1 2 ......Mounting Kit external IP EX .........................................91004 .............. 1 ....... - Screw ISO 7048 M5x20/12 ..Stainless Steel ..............7048052012 .... 1 ....... - Screw ISO 7048 M5x16/10 ..Stainless Steel ..............7048051610 .... 1 ....... - O-ring Ø3x2 NBR 70 ............Nitrile Rubber ................OR3x2NBR ..... 2 ....... - Screw ISO 4017 M6x40/10z Stainless Steel ..............4017064010z .. 2 ....... - Washer ISO 7089 M6 ..........Stainless Steel ..............708906 ............ 2 ....... - Mounting Plate IP ABB EX ...Aluminum, painted ........90046 .............. 1

3 .......External IP Module Gas Approved ................................93063 .............. 1 1 ...... IP Gas Approved ..........................................................Contact VAC ... 1 2 ......Mounting Kit external IP Gas Approved .......................91012 .............. 1 ....... - Screw ISO 7048 M5x20/12 ..Stainless Steel ..............7048052012 .... 1 ....... - Screw ISO 7048 M5x16/10 ..Stainless Steel ..............7048051610 .... 1 ....... - Screw NPT 1_4 ....................Stainless Steel ..............90089 .............. 2 ....... - O-ring Ø14x2 NBR70 ...........Nitrile Rubber ................OR14x2NBR ... 4 ....... - Mounting Plate FC X78 ........Aluminum, painted ........90079 .............. 1 4 .......External IP Module Fail Freeze .....................................93065 .............. 1 1 ..... IP Fail Freeze ................................................................Contact VAC ... 1 2 ......Mounting Kit external IP FA TA78+TA61 ......................91024 .............. 1 ....... - Screw ISO 7048 M5x20/12 ..Stainless Steel ..............7048052012 .... 1 ....... - Screw ISO 7048 M5x16/10 ..Stainless Steel ..............7048051610 .... 1 ....... - Screw #8-32 UNC 13 x 13 ...Stainless Steel ..............476208321313 3 ....... - Rubber Gasket IP TA78+TA61Nitrile Rubber ..............90142 .............. 1 ....... - Mounting Plate FA TA78 +TA61Aluminum, painted ....90085 .............. 1

Page 10: V200 POSITIONER - Valve Accessories & Controls, INCvacaccessories.com/wp-content/uploads/2017/08/92076r14-V200... · V200 POSITIONER ... cess water will eventually reach the control

V200 POSITIONERwww.vac.se

92076r1410

4.1 Specifications external options 0-10V EX Gas approved Fail Freeze V200 0-10V V200EX V200EX-GA V200FF Input Signal: 0-10VDC (Ri 10K Ohm) 4-20mA (Ri 260 Ohm) 4-20mA (Ri 10K Ohm) 4-20mA (Ri 197 Ohm)

Supply Pressure: 20-120 PSI 20-145 PSI 20-120 PSI 20-120 PSI (0.14 - 0.83 MPa) (0.14-1MPa) (0.14 - 0.83 MPa) (0.14 - 0.83 MPa)

Linearity error: <0.8% f.s <0.8% f.s <0.8% f.s <1.2% f.sHysteresis: <0.5% f.s <0.5% f.s <0.5% f.s <0.8% f.sRepeatability: <0.4% f.s <0.4% f.s <0.4% f.s <0.5% f.s

Temperature range: -40° to +160 F* -40° to +158 F* -40° to +160 F* -20° to +150 F -40° to +71C* -40° to +70°C* -40° to +71C* -30° to +65°C *Temperature range depending on certification Pressure gain:@87 PSI (600kPa) 300:1 300:1 300:1 300:1

Bleed Rate: SCFM (SLPM) SCFM (SLPM) SCFM (SLPM) SCFM (SLPM)@87PSI (600kPa) 0,51 (14.5) 0.43 (12.2) 0.51 (14.5) 0.43 (12.4)

Air Delivery SCFM (SLPM) SCFM (SLPM) SCFM (SLPM) SCFM (SLPM)

@87 PSI (600kPa) 28.3 (800) 28.3 (800) 28.3 (800) 28.3 (800)

Air connections: 1/4” NPT (optional G threads) Gauges: 1/8” NPT (optional G threads) Cable entry: 1/2” NPT (optional M20x1.5)

Ingress & corrosion protection: NEMA 4X and IP65

Standard coating: Polyester

Weight: 4.41 lbs (2.01kg) 4.70 lbs (2.13g) 5.75 lbs (2.61kg) 5.73 lbs (2.60kg) Weight with gauges: 4.63 lbs (2.10kg) 4.89 lbs (2.22kg) 5.95 lbs (2.7kg) 5.93 lbs (2.69kg)

Valve types. (SG/LB valve is installed as standard) SG/LB SHG (3) SHGSHF (4) Pressure Gain: @ 29 PSI (0.2MPa) Poutput / Pinput 80 367 370 @ 87 PSI (0.6MPa) Poutput / Pinput 240 1100 1100 @ 145 PSI (1.0MPa) Poutput / Pinput 400 1833 1830

Pressure Gain: Any %Poutput / %Pinput 16 79 72Acc. to ISA S75.13

Air Delivery: @ 29 PSI (0.2MPa) SCFM/(SLPM) 9.4 / (270) 10.5 / (297) 16.6 / (470) @ 87 PSI (0.6MPa) SCFM/(SLPM) 28.3 / (800) 31.5/ (890) 50.0 / (1400) @ 145 PSI (1.0MPa) SCFM/(SLPM) 47.1 / (1330) 52.5 / (1486) 83.4 / (2330)

Bleed Rate: @ 29 PSI (0.2MPa) SCFM/(SLPM) 0.07 / (3.4) 0.28 / (7.9) 0.4 / (12.3) @ 87 PSI (0.6MPa) SCFM/(SLPM) 0.2 / (5.6) 0.83 / (23.5) 1.3 / (36.8) @ 145 PSI (1.0MPa) SCFM/(SLPM) 0.35 / (10.0) 1.38 / (39.1) 2.2 / (61.3)

Options: Feedback Spring for 6-30 PSI (40-200kPa) input signal. Gauges. Stability kit, feedback modules.

4 SPECIFICATIONS

Page 11: V200 POSITIONER - Valve Accessories & Controls, INCvacaccessories.com/wp-content/uploads/2017/08/92076r14-V200... · V200 POSITIONER ... cess water will eventually reach the control

V200 POSITIONERwww.vacaccessories.com

92076r14 11

13/3

2"10Hex

siz

e

6 13/16"173,4

4 3/4"121

1 25/32"45

1 25/32"45

1 5/8"41

4 31/32"126,6

3/16"5

2 13/32"61

2 11

/16"

68

11 1

5/32

"29

1,1

10 2

1/32

"27

0,7

Gau

ges

1/8"

NP

T(4x

)(op

tiona

l)

1/2"

12,5

1 13

/32"

35,5

1 1/32"26,6

Con

duit

Ent

ry1/

2" N

PT

1 19

/32"

40,5

7/8"

22,5

1 9/

16"

39,5

2 1/16"52,5

1 3/16"30

3/16"5

1 3/8"35

Air

conn

ectio

ns1/

4" N

PT

(5x)

5/8"15,5

2 15/32"62,5

5/8"15,5

2 3/16"55,5

3 27/32"97,5

1 7/8"47,5

2 1/

4"57

31/3

2"25

2 7/

32"

56 2 31

/32"

75

5 1/

4"13

3

5"127

Dom

e In

dica

tor(

optio

nal)

Con

duit

Ent

ry1/

2" N

PT

(4x)

1 13

/32"

35,4

ISO

F05

Sqr

2 31

/32"

75,6

Sqr

2 15

/16"

754

1/4"

108

1 31/32"50

2 1/

4"57

,2

Wes

tlock

Sqr

.

Wes

tlock

(4x

)N

ot ta

pped

.

ISO

F05

(4x

)M

6 -

1/2"

[12m

m]

Dim

ensi

onal

Dra

win

gV

AC

Pos

ition

er V

200

0/10

V

5.1 V200E 0/10V

5 DIMENSIONS

Page 12: V200 POSITIONER - Valve Accessories & Controls, INCvacaccessories.com/wp-content/uploads/2017/08/92076r14-V200... · V200 POSITIONER ... cess water will eventually reach the control

V200 POSITIONERwww.vac.se

92076r1412

13/3

2"10Hex

siz

e

6 13/16"173,4

3/16"5

4 3/4"121

1 25/32"45

1 25/32"45

1 5/8"41

5 7/16"137,9

2 15

/16"

74,9

2 13/32"61

2 11

/16"

Ø68

3 31/32"100,4

11 9

/16"

294

8 3/

16"

207,

7

9 7/

8"25

1

Gau

ges

1/8"

NP

T(4

x)(o

ptio

nal)

1/2"

12,5

1 25

/32"

45,5

1 9/16"39,4

Con

duit

Ent

ry1/

2" N

PT

1 19

/32"

40,5

7/8"

22,5

1 9/

16"

39,5

2 1/16"52,5

1 3/16"30

3/16"5

1 3/8"35

Air

conn

ectio

ns1/

4" N

PT

(5x

)

3 27/32"97,5

5/8"15,5

2 15/32"62,5

4 27/32"123

7/16"10,8

1 7/8"47,5

2 1/

4"57

31/3

2"25

2 7/

32"

56 2 31

/32"

75

5 1/

4"13

3

6 11

/32"

161,

3

5"127

Dom

e In

dica

tor(

optio

nal)

Con

duit

Ent

ry1/

2" N

PT

1 13

/32"

35,4

ISO

F05

Sqr

2 31

/32"

75,6

Sqr

1 31/32"50

2 15

/16"

754

1/4"

108

2 1/

4"57

,2

Wes

tlock

Sqr

.

Wes

tlock

(4x

)N

ot ta

pped

.

ISO

F05

(4x

)M

6 -

1/2"

[12m

m]

Dim

ensi

onal

Dra

win

gV

AC

Pos

ition

er V

200

EX

5.2 V200EX

Page 13: V200 POSITIONER - Valve Accessories & Controls, INCvacaccessories.com/wp-content/uploads/2017/08/92076r14-V200... · V200 POSITIONER ... cess water will eventually reach the control

V200 POSITIONERwww.vacaccessories.com

92076r14 13

13/3

2"10Hex

siz

e

6 13/16"173,4

4 3/4"121

1 25/32"45

1 25/32"45

1 5/8"41

5 1/4"133,1

1 1/2"37,9

3 1/2"

89,2

2 11

/16"

68

3/16"5

2 13/32"61

12 7

/32"

310,

2

10 1

5/32

"26

5,6

3 15/32"87,9

Gau

ges

1/8"

NP

T(4x

)(op

tiona

l)

1/2"

12,5

1 19

/32"

40,5

7/8"

22,5

1 9/

16"

39,5

2 1/16"52,5

1 3/16"30

3/16"5

1 3/8"35

Air

conn

ectio

ns1/

4" N

PT

(5x)

3 27/32"97,5

5/8"15,5

2 15/32"62,8

2 7/8"73

5 5/16"135

5/8"15,5

1 7/8"47,5

2 1/

4"57

31/3

2"25

2 7/

32"

56 2 31

/32"

75

5 1/

4"13

3

6 1/

32"

153

4 1/

2"11

4

5"127

Dom

e In

dica

tor(

optio

nal)

Con

duit

Ent

ry1/

2" N

PT

1 13

/32"

35,4

ISO

F05

Sqr

2 31

/32"

75,6

Sqr

2 15

/16"

75

1 31/32"50

4 1/

4"10

8

2 1/

4"57

,2

Wes

tlock

Sqr

.

Wes

tlock

(4x

)N

ot ta

pped

.

ISO

F05

(4x

)M

6 -

1/2"

[12m

m]

Dim

ensi

onal

Dra

win

gV

AC

Pos

ition

er V

200

EX

-GA

5.3 V200EX-GA

Page 14: V200 POSITIONER - Valve Accessories & Controls, INCvacaccessories.com/wp-content/uploads/2017/08/92076r14-V200... · V200 POSITIONER ... cess water will eventually reach the control

V200 POSITIONERwww.vac.se

92076r1414

13/3

2"10Hex

siz

e

6 13/16"173,4

4 3/4"121

1 25/32"45

1 25/32"45

1 5/8"41

3/16"5

2 13/32"61

2 11

/16"

68

4 31/32"126,6 1 29/32"

48,311

7/1

6"29

0,7

10 2

9/32

"27

7

Gau

ges

1/8"

NP

T(4x

)(op

tiona

l)

1/2"

12,5

1 13

/32"

35,5

3 3/4"95,1

Con

duit

Ent

ry1/

2" N

PT

1 19

/32"

40,5

7/8"

22,5

1 9/

16"

39,5

2 1/16"52,5

1 3/16"30

3/16"5

1 3/8"35

Air

conn

ectio

ns1/

4" N

PT

(5x)

5/8"15,5

2 15/32"62,5

3 27/32"97,5

1 7/8"47,5

5/32"3,8

5/8"15,8

2 3/16"55,5

2 21/32"67,3

2 1/

4"57

31/3

2"25

2 7/

32"

56 2 31

/32"

75

5 1/

4"13

3

5"127

Dom

e In

dica

tor(

optio

nal)

Con

duit

Ent

ry1/

2" N

PT

(4x)

1 13

/32"

35,4

ISO

F05

Sqr

2 31

/32"

75,6

Sqr

2 15

/16"

754

1/4"

108

1 31/32"50

2 1/

4"57

,2

Wes

tlock

Sqr

ISO

F05

(4x)

M6

- 1/2

"[12

mm

]

Wes

tlock

(4x)

Not

tapp

ed.

Dim

ensi

onal

Dra

win

gV

AC

Pos

ition

er V

200F

F

5.4 V200FF

Page 15: V200 POSITIONER - Valve Accessories & Controls, INCvacaccessories.com/wp-content/uploads/2017/08/92076r14-V200... · V200 POSITIONER ... cess water will eventually reach the control

V200 POSITIONERwww.vacaccessories.com

92076r14 15

Intentionally blank

Page 16: V200 POSITIONER - Valve Accessories & Controls, INCvacaccessories.com/wp-content/uploads/2017/08/92076r14-V200... · V200 POSITIONER ... cess water will eventually reach the control
Page 17: V200 POSITIONER - Valve Accessories & Controls, INCvacaccessories.com/wp-content/uploads/2017/08/92076r14-V200... · V200 POSITIONER ... cess water will eventually reach the control