10
User Manual LED Dental Scaler, Drill and Polishing unit Eicksonic Plus 176880

User Manual LED Dental Scaler, Drill and Polishing unit ... · Operate handpiece only with the supplied foot pedal defects drill cause imbalance and lead to premature wear of the

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: User Manual LED Dental Scaler, Drill and Polishing unit ... · Operate handpiece only with the supplied foot pedal defects drill cause imbalance and lead to premature wear of the

User Manual

LED Dental Scaler, Drill and Polishing unit

Eicksonic Plus176880

Page 2: User Manual LED Dental Scaler, Drill and Polishing unit ... · Operate handpiece only with the supplied foot pedal defects drill cause imbalance and lead to premature wear of the

Table of Contents

Page

1. Scope.................................................................................................................. 3

2. Device overview and connections ....................................................................... 3 3. Operating the unit.............................................................................................. 5 3.1 Start up scaler........................................................................................... 5 3.2 Start up drill/polisher.................................................................................. 5 4. Safety Information.............................................................................................. 6 5. Conditions of use ….......................................................................................... 6 6. Maintenance........................................................................................................ 7

7. Cleaning and care.............................................................................................. 7 8. Troubleshooting................................................................................................... 8

9. Recommended Accessories.............................................................................. 9

Important Note:

Please read the operating instructions carefully before starting.The operation must be performed by trained and qualified personnel.Intervention in the appliance must be carried out only by authorized specialist companies.The appliance must not come into contact with liquids and may be operated only with the specified rated voltage (220-230 V).

2/10

Page 3: User Manual LED Dental Scaler, Drill and Polishing unit ... · Operate handpiece only with the supplied foot pedal defects drill cause imbalance and lead to premature wear of the

1. Scope of delivery:

1 Eick Sonic Plus basic unit (electric component) with a permanently fitted Scaler1 tartar removal Lace Set (2 x flat, wide, 2 x flat, pointed, 1 x point-like)1 key to attach the tips on Scaler1 Micro motor with connection cable and 3-pin DIN connector1 external power supply 230 V / 24 V AC (alternating current) 1.3 A with connection cable1 Water connection hose with connector for 3/8 "water line and T-distribution1 Foot Switch

2. Views of the device and connections:

Front:

1. Scaler adjuster (intensity level) for Ultrasonic Scaler2. Function switch for scaler (ultrasound) or Micro motor operation (drill unit) with foot / hand control3. Controls for the left / right directions and speed for the drill unit

Back:

4. Socket for Micro motor (drill unit)5. Connection socket for footswitch6. Socket for power supply 24V AC (alternating current) 1.3 A7. Amounts of water adjuster for the scaler8. Connection for water supply. Caution: 0.01 to 0.5 MPa (0.1 to 5.0 bar) Use only clean, filtered or distilled water.

3/10

Page 4: User Manual LED Dental Scaler, Drill and Polishing unit ... · Operate handpiece only with the supplied foot pedal defects drill cause imbalance and lead to premature wear of the

Left:

9. Holder for the Scaler (Ultrasonic dental scalerhandpiece)

Right:

10. Holder for the micro motor without drill attachment

11. footswitch

4/10

Page 5: User Manual LED Dental Scaler, Drill and Polishing unit ... · Operate handpiece only with the supplied foot pedal defects drill cause imbalance and lead to premature wear of the

3. Unit into operation :

3.1 Commissioning Scaler with LED lighting

1. Turn the water control knob (7 ) counterclockwise to maximum and the scaler knob (1 ) counterclockwise to the position ( min. ) .2. Connect the foot switch ( 11) with the socket (5) control unit.3. Connect the water supply hose to the water input ( 8) and the other end using the supplied connector to a water source ( Line , angle valve or water pressure tank) to .4. Turn a scaler tip in the scaler handpiece and pull the top with the supplied key firmly.5. Connect the device-side power cable to the unit to the jack ( 6) and the Power adapter to the power grid.6. Set the desired intensity level using the adjuster ( 1) and start or stop the function with the foot switch.7. Correct the desired amount of water with the adjusters (7 ) on the back .

3.2 Commissioning Drill/Polisher

1. Check if the power is off (the adjuster (2) and (3) to "0").2. Connect the Micro motor with the socket (4) of the control unit.3. Unscrew the dust cap from the micro engine and plug the Handpiece (not included) on. Product No.: 174 026 angle or straight handpiece 1740274. Insert the drill bit (not included in scope of supply) in the appropriate handpiece. To lockthe drills please refer to the operating instructions of the handpieces. Check the correct position by turning the hand piece or gently pulling on the drill.5. Turn the mode selector switch (2) to micromotor foot operation or manual operation6. Use the adjuster (3) the desired direction of rotation and adjust the desired rotational speed "min -. maximum." one.7. With the foot switch (11) to start the engine or turn it off.

5/10

Regularly check your scaler tips using the supplied Picture for wear. In case of heavy wear urgently replace the tips.

Page 6: User Manual LED Dental Scaler, Drill and Polishing unit ... · Operate handpiece only with the supplied foot pedal defects drill cause imbalance and lead to premature wear of the

IMPORTANT: Before you replace the drill, turn off the power. Prefs (2) to "0" and the speed control "Micromotor" (3) to "0" provide.

4. Safety:

1. Keep the unit away from children.2. The device may only be used in accordance with its intended purpose.3. In case of a defective cable, the device must not be operated.4. Please follow the care instructions in the user manual the handpieces.5. If you want to change the drill bit, turn the power off.6. The scaler tip has to vibrate / the drill has to rotate before it can be placed on a tooth.7. Wear eye protection during work and provide for an adequate suction.8. Do not Clean or oil the handpiece during operation.9. Leave after operation a drill or the supplied dummy pin in Handpiece clamped.

5. Operating conditions:

Temperature: +10 ° C ~ +40 ° CHumidity: 30% ~ 75%Air pressure: 700 ~ 1060 hPa (0.7 to 1.06 bar)

Operate handpiece only with the supplied foot pedal defects drill cause imbalance and lead to premature wear of the bearings

6. Maintenance:

The drill/poliosher is maintenance-free. Only the carbon brushes in the motor Micro should be replaced annually. Please send your Micro motor to us for maintenance.

7. Cleaning and care:Micro motor and handpiecesIt is imperative the handpieces be thoroughly cleaned and oiled after each.(Suggested Spray: Article 174010 and adapter 17.40115 million).

6/10

Hold the straight handpiece down during operation so that no water anddirt runs in the micro motor.The micro motor is not internally waterproof.

Page 7: User Manual LED Dental Scaler, Drill and Polishing unit ... · Operate handpiece only with the supplied foot pedal defects drill cause imbalance and lead to premature wear of the

Oil the Micro Motors Micro motor after the oil with the head hanging down in the holder (10)

Oil the straight handpiece Demo days before and after the installation Oiling the angle handpiece inside

Oiling the angle handpiece outside Oiling the angle handpiece inside

Store the Handpieces separately after oiling Do not Fit.

7/10

Page 8: User Manual LED Dental Scaler, Drill and Polishing unit ... · Operate handpiece only with the supplied foot pedal defects drill cause imbalance and lead to premature wear of the

Scaler with LED lighting

Remove the scaler tip with the including key ring.

Remove the screw and clean the shaft with alcohol.Remove the trim ring on the handle of the Scalerhandstücks and clean with alcohol.

Disconnect the main handpiece from the scaler and autoclave under high temperature and pressure disinfection (135 ° C, 12:22 Mpa)

8. Troubleshooting:

1. Check the fit of the power plug2. Check the power cable of the handpiece3. Check the fuse4. Check whether the device is switched on5. Check the carbon brushes are worn and if they need to be replaced (see Maintenance)

8/10

Page 9: User Manual LED Dental Scaler, Drill and Polishing unit ... · Operate handpiece only with the supplied foot pedal defects drill cause imbalance and lead to premature wear of the

9. Recommended Accessories:

Angle handpiece Straight handpiece Plastic polishing attachments Tooth polish with rubber polishing cup 174026 174027 174064 176781

Replacement Tips for Spray for rotating Plug adapters for useTartar device Instrument with spray174010 174010 17401150

9/10

Page 10: User Manual LED Dental Scaler, Drill and Polishing unit ... · Operate handpiece only with the supplied foot pedal defects drill cause imbalance and lead to premature wear of the

GERMANY

EICKEMEYER KGEltastraße 878532 TuttlingenT +49 7461 96 580 0 F +49 7461 96 580 90E [email protected]

CANADA

EICKEMEYER Inc.250 Briarhill Dr.Stratford, Ont. CanadaN5A 7S2T +1 519 273 5558F +1 519 271 7114E [email protected] www.eickemeyerveterinary.com

DENMARK EICKEMEYER ApSLysbjergvej 6, Hammelev6500 Vojens T +45 7020 5019F +45 7353 5019E [email protected]

ITALY

EICKEMEYER S.R.L.Via G. Verdi, 8 65015 Montesilvano (PE)T +39 085 935 4078 F +39 085 935 9471E [email protected]

NETHERLANDS

EICKEMEYER B.V.Bedrijventerrein Pavijen-West Bellweg 444104 BJ CulemborgT +31 345 58 9400F +31 345 58 9401E [email protected]

POLAND

EICKEMEYER Sp. z o.o. Al. Jana Pawła II 27 00-867 Warszawa T +48 22 185 55 76 F +48 22 185 59 40 E [email protected]

SWITZERLAND

EICKEMEYER AGSandgrube 299050 Appenzell T +41 71 788 23 13 F +41 71 788 23 14E [email protected]

UNITED KINGDOM

EICKEMEYER Ltd.3 Windmill Business Village Brooklands CloseSunbury-on-Thames Surrey, TW16 7DYT +44 20 8891 2007F +44 20 8891 2686E [email protected]