18
4 5 Ultrasonic scaling at a precise and steady vibration prevents damage of the natural tooth structure. Ten versions of NSK Varios Scaling tips allow the removal of supragingival calculus, interdental calculus, and calculus at the tooth neck. SCALING

Ultrasonic scaling at a precise and steady SCALINGpromosadental.tripod.com/sitebuildercontent/sitebuilderfiles/pun... · 4 5 Ultrasonic scaling at a precise and steady vibration prevents

Embed Size (px)

Citation preview

Page 1: Ultrasonic scaling at a precise and steady SCALINGpromosadental.tripod.com/sitebuildercontent/sitebuilderfiles/pun... · 4 5 Ultrasonic scaling at a precise and steady vibration prevents

4 5

Ultrasonic scaling at a precise and steady

vibration prevents damage of the natural

tooth structure. Ten versions of NSK Varios

Scaling tips allow the removal of supragingival

calculus, interdental calculus, and calculus at

the tooth neck.

SCAL ING

Page 2: Ultrasonic scaling at a precise and steady SCALINGpromosadental.tripod.com/sitebuildercontent/sitebuilderfiles/pun... · 4 5 Ultrasonic scaling at a precise and steady vibration prevents

6 7Refer to the power setting chart on pages 44-45.Satelec® is registered trademarks of Acteon SA, France. EMS® is registered trademarks of Electro Medical Systems SA, Switzerland.

S C A L I N G

G1To remove calculus on anterior teeth, the neck of molars, and supragingival calculus, the side of the Varios tip should beplaced on the tooth and moved sideways.

G2To remove heavy calculus place the top of the G2 flat tip against the tooth plane and activitate the ultrasonic scaler.

G3To remove heavy nicotine stains, place the top and the side of the tip on the tooth plane and gently move the tip up anddown.

20.0

11.1

MODEL ORDER CODE

Z217-101

Z291-101

G1

G1-E

Z217-102

Z291-102

G2

G2-E

Z217-103

Z291-103

G3

G3-E

G4Removal of subgingival and interdental calculus from anterior and molar teeth. To remove calculus from anterior teeth,place the top of the tip on the neck of the tooth and move it along the tooth plane.

G5To remove interdental calculus and calculus in pockets, insert the tip between the teeth while touching the tip on the tooth.

G6Insert the tip between teeth and remove calculus while keeping the top of the tip on the tooth plane to remove tartar.

MODEL ORDER CODE

Z217-104

Z291-104

G4

G4-E

Z217-106

Z291-106

G6

G6-E

NSK

Satelec® Z217-105G5

7.2

23.3

23.4

7.0

8.1

23.0

20.1

11.2

23.2

11.4

NSK

Satelec®

EMS®

NSK

Satelec®

EMS®

NSK

Satelec®

EMS®

NSK

Satelec®

EMS®

NSK

Satelec®

EMS®

Page 3: Ultrasonic scaling at a precise and steady SCALINGpromosadental.tripod.com/sitebuildercontent/sitebuilderfiles/pun... · 4 5 Ultrasonic scaling at a precise and steady vibration prevents

8 Satelec® is registered trademarks of Acteon SA, France. 9Refer to the power setting chart on pages 44-45.

S C A L I N G

G7Removal of interdental heavy calculus.

G11Universal type. Removal of calculus from a wide plane such as anterior teeth.

G12Perio type. The tip with the sharp angle removes calculus of the molar.

NSK

Satelec® Z217-411G11

MODEL ORDER CODE

NSK

Satelec® Z217-107G7

NSK

Satelec® Z217-412G12

G13Sickle type. It is suitable for removing calculus of the neck and interdental calculus.

MODEL ORDER CODE

NSK

Satelec® Z217-413G1323.3

8.8

23.1

6.9

22.9

7.4

6.7

22.2

Page 4: Ultrasonic scaling at a precise and steady SCALINGpromosadental.tripod.com/sitebuildercontent/sitebuilderfiles/pun... · 4 5 Ultrasonic scaling at a precise and steady vibration prevents

10 11

Varios tips, angled from right and left,

plus straight, are available to provide

the best approach to furcation and

curved root faces.

P E R I O

Page 5: Ultrasonic scaling at a precise and steady SCALINGpromosadental.tripod.com/sitebuildercontent/sitebuilderfiles/pun... · 4 5 Ultrasonic scaling at a precise and steady vibration prevents

12 Satelec® is registered trademarks of Acteon SA, France. 13Refer to the power setting chart on pages 44-45.

27.0

7.4

P E R I O ( R O O T P L A N I N G )

P1

• Diamond coated

P1DP1D is diamond coated tip and its shape is the same as P1 tip. Designed for the removal of fine calculus and for the finishing of root planing.

P10To remove subgingival stains, the tip may be used as per manual curettes.

P2D

P2D Right curved tip

P3D Left curved tip

Diamond coated tip effectively removes persistent subgingival calculus.Right curved tip.

P3DLeft curved tip.

• Sharp edge

Ultra thin tips provide easy access to anterior teeth, narrow pockets and complex crowded teeth.

P2D / P3D (From above)

MODEL ORDER CODE

NSK

Satelec® Z217-404P1

NSK

Satelec® Z217-405P1D

NSK

Satelec® Z217-410P10

MODEL ORDER CODE

NSK

Satelec® Z217-402P2D

NSK

Satelec® Z217-403P3D

27.0

6.9

27.0

6.9

31.6

6.8

27.0

7.4

• Diamond coated

• Diamond coated

Per io Ki t A

NSK

Satelec® Y900-144Perio Kit A

• P1D, P2D, P3D, P10 : 1 pc. each

• Tip holder : 1 pc.

Page 6: Ultrasonic scaling at a precise and steady SCALINGpromosadental.tripod.com/sitebuildercontent/sitebuilderfiles/pun... · 4 5 Ultrasonic scaling at a precise and steady vibration prevents

14 15Refer to the power setting chart on pages 44-45.Satelec® is registered trademarks of Acteon SA, France. EMS® is registered trademarks of Electro Medical Systems SA, Switzerland.

P21RRight curved tip.

P E R I O ( R O O T P L A N I N G )

P21LLeft curved tip.

P20Straight tip.

P25RFor root planning of molar furcation and complicated curve.Right curved tip.

P25LLeft curved tip.

MODEL ORDER CODE

Z217-420

Z291-420

P20

P20-E

Z217-422

Z291-422

P21R

P21R-E

MODEL ORDER CODE

Z217-424

Z291-424

P25R

P25R-E

Z217-425

Z291-425

P25L

P25L-E

Z217-421

Z291-421

P21L

P21L-E

P21R Right curved tip

P20 Straight tip

P21L Left curved tip

P25R Right curved tip

P25L Left curved tip

P21R / P20 / P21L / P25R / P25L (From above)

28.5

12.3

27.7

11.4

27.7

11.4

27.2

7.6

27.2

7.6

NSK

Satelec®

EMS®

NSK

Satelec®

EMS®

NSK

Satelec®

EMS®

NSK

Satelec®

EMS®

NSK

Satelec®

EMS®

Per io Ki t B

NSK

Satelec® Y900-145Perio Kit B

• P20, P25R, P25L : 1 pc. each

• Tip holder : 1 pc.

Page 7: Ultrasonic scaling at a precise and steady SCALINGpromosadental.tripod.com/sitebuildercontent/sitebuilderfiles/pun... · 4 5 Ultrasonic scaling at a precise and steady vibration prevents

16 Satelec® is registered trademarks of Acteon SA, France. 17Refer to the power setting chart on pages 44-45.

14.8

7.9

P41

P E R I O ( I r r igat ing and C lean ing ) MAINTENANCE (V-T ip)

P40

MODEL ORDER CODE

NSK

Satelec® Z217-550P40

NSK

Satelec® Z217-555P41

Y900-184V-P10

V-P10• Pack of 3

V10

*Plastic Tip is not included

MODEL ORDER CODE

NSK

Satelec® Z217-041V10

17.8

28.9

3

6

14.7

ø 0.6

28.9

14.4

ø 0.8

3

6

Dual irrigation points

• Irrigation from dual points on lateral areas of the apex.

• Effective cleaning regardless of the insertion angle.

• Safe to use regardless of the pocket condition due to the marking

guideline of 3 mm from the position of 6 mm.

• The rounded apex shape for safety in periodontium.

For effective cleaning following debridement or scaling. For the maintenance of prostheses and implants.

Produced from special material to allow safe debridement

without causing damage to metals and implants.

• Tip diameter ø 0.6 mm

• Tip diameter ø 0.8 mm

Page 8: Ultrasonic scaling at a precise and steady SCALINGpromosadental.tripod.com/sitebuildercontent/sitebuilderfiles/pun... · 4 5 Ultrasonic scaling at a precise and steady vibration prevents

NSK offers endodontic tips to achieve quick

and effective treatments for root canal

enlarging, irrigation, and filling. File and

diamond tips for root canal enlarging, tips

for root canal irrigation, tips for gutta-percha

filling, tips for removal of materials and

foreign bodies in root canal.

18 19

ENDODONTICS

Page 9: Ultrasonic scaling at a precise and steady SCALINGpromosadental.tripod.com/sitebuildercontent/sitebuilderfiles/pun... · 4 5 Ultrasonic scaling at a precise and steady vibration prevents

20 Satelec® is registered trademarks of Acteon SA, France. 21Refer to the power setting chart on pages 44-45.

ENDODONTICS

E4Application for root canal cleaning and removal of foreign particles.

E7Removal of filling and foreign material.

E8

28.4

26.0

8

29.6

• Water not required

• Water not required

E4D

E7DEnlargement of root canal wall.

E8D

• Diamond coated

• Diamond coated

• Diamond coated

MODEL ORDER CODE

NSK

Satelec® Z217-428E4

MODEL ORDER CODE

NSK

Satelec® Z217-528E4D

NSK

Satelec® Z217-317E7D

NSK

Satelec® Z217-318E8D

NSK

Satelec® Z217-307E7

NSK

Satelec® Z217-308E8

24.1

16.0

20.6

Enlargement of root canal wall.

24.1

16.0

13.0

20.6

with diamond

28.4

26.0

23.0

29.6

with diamond

23.2

15.8

14.6

23.2

15.8

14.6

10.0 with diamond

Removal of filling and foreign material.

Application for root canal cleaning and root canal enlargement.

In order to reduce the

incidence of ledge formation,

no diamond coating is

attached from the end up to

1mm of the tip.

*

1.0

Page 10: Ultrasonic scaling at a precise and steady SCALINGpromosadental.tripod.com/sitebuildercontent/sitebuilderfiles/pun... · 4 5 Ultrasonic scaling at a precise and steady vibration prevents

22 Satelec® is registered trademarks of Acteon SA, France. 23Refer to the power setting chart on pages 44-45.

E5Lateral condensation.

E6

Endo Ki t E11

Lateral condensation.

• Water not required

• Water not required

U f i lesLength : 33 mmShank dia. : 0.8 mm

• For U files (Shank dia : 0.8 mm) • For root canal cleaning • For anterior teeth• Includes E Tip replacement wrench

*File is optional

• For U files (Shank dia : 0.8 mm) • For root canal cleaning • For posterior teeth• Includes E Tip replacement wrench

*File is optional

• ISO15 • Pack of 6

• ISO20 • Pack of 6

• ISO25 • Pack of 6

• ISO30 • Pack of 6

• ISO35 • Pack of 6

MODEL ORDER CODE

NSK

Satelec® Z217-305E5

MODEL ORDER CODE

NSK

Satelec® Z217-031E11

NSK

Satelec® Z217-032E12

NSK

Satelec® Z217-306E6

NSK

Satelec® Y900-146Endo Kit E11

Y900-062

Y900-063

Y900-064

Y900-065

Y900-066

U files 33 mm / #15

U files 33 mm / #20

U files 33 mm / #25

U files 33 mm / #30

U files 33 mm / #35

• E11 : 1 pc.

• E Tip replacement wrench : 1 pc.

• U files 33 mm #15, #20, #25, #30, #35 :

Pack of 6 each size

NSK

Satelec® Y900-147Endo Kit E12

• E12 : 1 pc.

• E Tip replacement wrench : 1 pc.

• U files 33 mm #15, #20, #25, #30, #35 :

Pack of 6 each size

21.5

17.0 21.5

24.3

20.0

21.3

15.2

12.8

12.6

95 16.2

E11120˚ Angle Holder for U files

E1295˚ Angle Holder for U files

for anterior teeth

Endo Ki t E12for posterior teeth

ENDODONTICS

Page 11: Ultrasonic scaling at a precise and steady SCALINGpromosadental.tripod.com/sitebuildercontent/sitebuilderfiles/pun... · 4 5 Ultrasonic scaling at a precise and steady vibration prevents

25Refer to the power setting chart on pages 44-45.24 Satelec® is registered trademarks of Acteon SA, France.

ENDODONTICS (V-Tip)

V-S50

ø1.5

12.6

ø1.5

18.2

ø1.5

21.2

ø1.5

27.2

• For root canal cleaning 17 mm• Pack of 3

V-S51• For root canal cleaning 23 mm• Pack of 3

V-S52• For root canal cleaning 26 mm• Pack of 3

V-S53• For root canal cleaning

32 mm• Pack of 3

Y900-169V-S50

Y900-170V-S51

Y900-171V-S52

Y900-172V-S53

Y900-173V-S50D

Y900-174V-S51D

Y900-175V-S52D

Y900-176V-S53D

ø1.5

12.6

9.1 with diamond

ø1.5ø1.5

16.0 with diamond

18.2

ø1.5

19.0 with diamond

21.2

ø1.5

25.0 with diamond

27.2

V30

In order to reduce the incidence of

ledge formation, no diamond coating

is attached from the end up to 1mm

of the tip.

• Includes E Tip replacement wrench

*Tip is optional• Includes E Tip replacement wrench

*Tip is optional

MODEL ORDER CODE

NSK

Satelec® Z217-030V30

29.5

8.3

MODEL ORDER CODE

NSK

Satelec® Z217-030V30

29.5

8.3

V-S50D• Diamond coated• For root canal enlargement 17 mm• Pack of 3

V-S51D• Diamond coated• For root canal enlargement 23 mm• Pack of 3

V-S52D• Diamond coated• For root canal enlargement 26 mm• Pack of 3

V-S53D• Diamond coated• For root canal enlargement

32 mm• Pack of 3

For Root Canal Cleaning For Root Canal Enlargement

V30

1.0 *

Page 12: Ultrasonic scaling at a precise and steady SCALINGpromosadental.tripod.com/sitebuildercontent/sitebuilderfiles/pun... · 4 5 Ultrasonic scaling at a precise and steady vibration prevents

27Refer to the power setting chart on pages 44-45.26 Satelec® is registered trademarks of Acteon SA, France.

The microscopic diamond coated tip allows effective removal of dentin at the apex.

2 types of angled tips (90°, 70°) are available for anterior teeth and another 2 types

of curved tips (right and left) are available for molar.

RETROGRADE ENDO

E32D

• Diamond coated• For anterior and posterior teeth (70˚)

• Diamond coated• For anterior teeth (90˚)

Diamond coated tip allows efficient cavity preparation.

E31DDiamond coated tip allows efficient cavity preparation.

NSK

Satelec® Z217-211E32D

MODEL ORDER CODE

NSK

Satelec® Z217-210E31D

18.9

13.4

17.8

12.5

E30RD

E30LD

Diamond coated tip allows efficient cavity preparation.

20.2

12.2 MODEL ORDER CODE

NSK

Satelec® Z217-212E30RD

NSK

Satelec® Z217-213E30LD20.2

12.2

• Diamond coated• For posterior teeth (right angled)

• Diamond coated• For posterior teeth (left angled)

NSK

Satelec® Y900-149Retro Kit

• E30RD, E30LD, E31D, E32D : 1 pc. each

• Tip holder : 1 pc.

Retro Ki t

Diamond coated tip allows efficient cavity preparation.

Page 13: Ultrasonic scaling at a precise and steady SCALINGpromosadental.tripod.com/sitebuildercontent/sitebuilderfiles/pun... · 4 5 Ultrasonic scaling at a precise and steady vibration prevents

28 29

Ultrasonic vibration is applied to the tooth

surface. The compact handpiece is ideal for

small mouths and at sites where a rotary

handpiece is difficult to access. A variety of

tips are available for caries removal and

tooth surface characterization.

RESTORATIVE

Page 14: Ultrasonic scaling at a precise and steady SCALINGpromosadental.tripod.com/sitebuildercontent/sitebuilderfiles/pun... · 4 5 Ultrasonic scaling at a precise and steady vibration prevents

31Refer to the power setting chart on pages 44-45.30 Satelec® is registered trademarks of Acteon SA, France.

0.9

1.5

0.6

1.0

F o r M i n i m a l I n t e r v e n t i o n

R E S T O R AT I V E ( V- T i p )

Y900-118V-G70

Y900-119V-G71

Y900-121V-G75

Y900-122V-G76

Y900-120V-G72

ø1.5

12.3

ø1.5

12.0V-G70

• Diamond coated• Pack of 3

V-G71• Diamond coated• Pack of 3

V-G72• Diamond coated• Pack of 3

• Includes E Tip replacement wrench

*Tip is optional

MODEL ORDER CODE

NSK

Satelec® Z217-030V30

29.5

8.3

• Includes E Tip replacement wrench

*Tip is optional

MODEL ORDER CODE

NSK

Satelec® Z217-030V30

29.5

8.3

ø 1.2

ø 0.8

ø 1.6 ø1.5

12.8

ø1.5

12.5

ø1.5

12.5

V-G75

• Diamond coated• Pack of 3

V-G76• Diamond coated• Pack of 3

V30 V30

• V-G70, V-G71, V-G72, V-G75,

V-G76 : 1 pc. each

Assorted Tip Ki t

NSK

Satelec® Y900-150MI Starter Kit

• V30 V-tip holder : 1 pc

• E Tip replacement wrench : 1 pc

• V-G70, V-G71, V-G72, V-S1, V-S3, V-S33

V-G77, V-G78, V-G79 : 1 pc. each

MI Starter Ki t

The NSK Varios V-Tip System has been developed to meet “Minimal Intervention”

dental procedures. As a variation to rotary cutting, the Varios V-Tip offers precise

and effective ultrasonic technology cutting. The advantage of ultrasonic cutting

decay removal is that tip movement is minute allowing only decayed dentine to be

removed, while sound dentine is preserved.

Y900-158AssortedTip Kit

Page 15: Ultrasonic scaling at a precise and steady SCALINGpromosadental.tripod.com/sitebuildercontent/sitebuilderfiles/pun... · 4 5 Ultrasonic scaling at a precise and steady vibration prevents

32 Satelec® is registered trademarks of Acteon SA, France. 33Refer to the power setting chart on pages 44-45.

ø1.5

12.5

ø1.5

12.5

ø1.5

12.5

For F in ish ing / Tr imming / Pol ish ing

R E S T O R AT I V E ( V- T i p )F o r C a r i e s o f D e n t i n

R E S T O R AT I V E ( V- T i p )

V-S1• Stainless tip• Pack of 3

V-S3• Stainless tip• Pack of 3

V-S33• Stainless tip• Pack of 3

Y900-165V-G77

Y900-166V-G78

Y900-167V-G79

Y900-168AssortedTip Kit

Y900-161V-S1

Y900-162V-S3

Y900-163V-S33

ø1.5

12.5

ø 0.8

0.9

ø 1.1

1.2

ø1.5

12.5

ø1.5

12.5

ø 0.8

2.6

V-S1, V-S3 and V-S33 are very effective in minimal intervention cavity preparation.

3 types of tips are available in response to cavity preparation requirements.

V-G77Normal grade

Three grades of diamond particles are available – Normal, Fine and Super

Fine – for tooth surface characterization to polishing.

ø 1.2

ø 1.2

ø 1.2

4.5

4.5

4.5

• Diamond coated• Pack of 3

V-G78Fine grade

• Diamond coated• Pack of 3

V-G79Super fine grade

• Diamond coated• Pack of 3

V30 V30

• Includes E Tip replacement wrench

*Tip is optional

MODEL ORDER CODE

NSK

Satelec® Z217-030V30

29.5

8.3

• Includes E Tip replacement wrench

*Tip is optional

MODEL ORDER CODE

NSK

Satelec® Z217-030V30

29.5

8.3

Assorted Tip Ki t

• V-G77, V-G78, V-G79 : 1 pc. each

Y900-164AssortedTip Kit

• V-S1, V-S3, V-S33 : 1 pc. each

Assorted Tip Ki t

Page 16: Ultrasonic scaling at a precise and steady SCALINGpromosadental.tripod.com/sitebuildercontent/sitebuilderfiles/pun... · 4 5 Ultrasonic scaling at a precise and steady vibration prevents

34 Satelec® is registered trademarks of Acteon SA, France. 35Refer to the power setting chart on pages 44-45.

F o r M i n i m a l I n t e r v e n t i o n

R E S T O R AT I V E

G61DUse the tip with the spherical diamond at the top. Bleeding scarcely occurs. (G61D / G62D)

G62D

MODEL ORDER CODE

NSK

Satelec® Z217-601G61D

NSK

Satelec® Z217-602G62D

28.0

7.8

28.0

7.9

G65DFor molar, interdental proximal caries. The hemispherical top of the tip does not allow cutting of sound tooth.(G65D / G67D / G66D / G68D)

NSK

Satelec® Z217-605G65D27.9

7.6

• Diamond coated

• Diamond coated

• Diamond coated

G66DFor anterior proximal caries. Only decayed dentin can be removed as per for molars.(G65D / G67D / G66D / G68D)

G68D

NSK

Satelec® Z217-606G66D

NSK

Satelec® Z217-608G68D

27.6

7.7

27.8

8.0

G67D

MODEL ORDER CODE

NSK

Satelec® Z217-607G67D28.2

7.8

• Diamond coated

• Diamond coated

• Diamond coated

0.9

1.0

1.23

1.4

1.33

0.75

1.63

1.0

1.330.75

1.631.0

Page 17: Ultrasonic scaling at a precise and steady SCALINGpromosadental.tripod.com/sitebuildercontent/sitebuilderfiles/pun... · 4 5 Ultrasonic scaling at a precise and steady vibration prevents

36 37

Tips for the removal of prostheses, for amalgam

filling condensation are provided as well as for

scaling, perio and endodontic.PROSTHETICS

Page 18: Ultrasonic scaling at a precise and steady SCALINGpromosadental.tripod.com/sitebuildercontent/sitebuilderfiles/pun... · 4 5 Ultrasonic scaling at a precise and steady vibration prevents

38 Satelec® is registered trademarks of Acteon SA, France. 39Refer to the power setting chart on pages 44-45.

G26Post removal.

G28Amalgam condensation.

• Water not required

G25Crown removal.

• Water not required

MODEL ORDER CODE

NSK

Satelec®Z217-205G25

MODEL ORDER CODE

NSK

Satelec® Z217-010G21

NSK

Satelec® Z217-020G22NSK

Satelec® Z217-206G26

NSK

Satelec® Z217-208G28

Condensation / Loosening / Plugging

P R O S T H E T I C S

Ultrasonic vibration removes bubbles in the cement for precise cementation.

• For anterior teeth • Water not required• 3 caps supplied

• For posterior teeth• Water not required• 3 caps supplied

G21

G22

Tip Cap

Ultrasonic vibration removes bubbles in the cement for precise cementation.

9.1

25.7

23.6

10.8

23.2

9.0

ø1.65

23.9

7.6

ø1.3

22.9

9.0

• For G21 / G22• Pack of 10

• Autoclavable

Y140-751Tip Cap