Trinzic Reporting 1400 Guia de Instalacao

Embed Size (px)

Citation preview

  • 8/17/2019 Trinzic Reporting 1400 Guia de Instalacao

    1/28

    For the Trinzic 1400 Appliances 1

    Infoblox Installation Guide

    Trinzic Reporting 1400 Appliance

  • 8/17/2019 Trinzic Reporting 1400 Guia de Instalacao

    2/28

    Copyright Statements© 2013, Infoblox Inc.— All rights reserved.

     

    The contents of this document may not be copied or duplicated in any form, in whole or in part, without

    the prior written permission of Infoblox, Inc.

    The information in this document is subject to change without notice. Infoblox, Inc. shall not be liable

    for any damages resulting from technical errors or omissions which may be present in this document, or

    from use of this document.

    This document is an unpublished work protected by the United States copyright laws and is proprietary

    to Infoblox, Inc. Disclosure, copying, reproduction, merger, translation, modification, enhancement, or

    use of this document by anyone other than authorized employees, authorized users, or licensees ofInfoblox, Inc. without the prior written consent of Infoblox, Inc. is prohibited.

    For Open Source Copyright information, refer to the Infoblox NIOS Administrator Guide .

    Trademark StatementsInfoblox, the Infoblox logo, Grid, NIOS, bloxTools, NetMRI, Trinzic and PortIQ are trademarks or

    registered trademarks of Infoblox Inc.

    All other trademarked names used herein are the properties of their respective owners and are used foridentification purposes only.

    Company Informationhttp://www.infoblox.com/contact/

    Product Information

      ardware Models

    Trinzic product line: 100, 810, 820, 1410, 1420, 2210, 2220, and Infoblox-4010

    Trinzic Reporting: 1400, 2000, 2200, and 4000

    Infoblox-4030 DNS Caching Accelerator Appliance

    Infoblox-250-A, -550-A, -1050-A, -1550-A, -1552-A, -1852-A, and -2000-A

    Network Automation: NetMRI-1102-A, NT-1400, NT-2200, and NT-4000

    Document Number: 400-0445-000 Rev. C

    Document Updated: August 7, 2013

    Warranty Information Your purchase includes a 90-day software warranty and a one year limited warranty on the Infoblox

    appliance, plus an Infoblox Warranty Support Plan and Technical Support. For more information about

    Infoblox Warranty information, refer to Infoblox Web site, or contact Infoblox Technical Support.

    http://www.infoblox.com/contacthttp://www.infoblox.com/contact

  • 8/17/2019 Trinzic Reporting 1400 Guia de Instalacao

    3/28

      3

    Contents

    Introduction  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

    Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

    Hardware Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .610 Gigabit Ethernet Support  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10System, Environmental, and Power Specifications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

    Installing an Appliance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

    Rack Mounting  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Powering the Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Cabling the Appliance to a Network  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

     Accessing the Appliance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

    Connecting to the Appliance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

    Specifying Appliance Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

    Infoblox GUI  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Infoblox CLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

    System Device Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23

    Managing the Disk Subsystem  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Hard Disk Drive Replacement  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Changing AC Power Supplies. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

    Replaceable Units and SFPs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

    Infoblox Installation GuideFor the Trinzic Reporting 1400 Appliance

    http://-/?-http://-/?-

  • 8/17/2019 Trinzic Reporting 1400 Guia de Instalacao

    4/28

    Contents

    4 Infoblox Installation Guide

  • 8/17/2019 Trinzic Reporting 1400 Guia de Instalacao

    5/28

    For the Trinzic Reporting 1400 Appliance 5

    Introduction

    This guide provides an overview of the Trinzic Reporting 1400 network appliance, and explains how to install andconfigure the system. You can add the Trinzic Reporting 1400 appliance as a member to the Infoblox Grid andconfigure it as a dedicated logging and reporting appliance. Note that you cannot configure the reporting applianceas an HA pair.

    The Infoblox reporting solution automates the collection, analysis, and presentation of core network service datathat assists you in planning and mitigating network outage risks, so you can manage your networks more efficiently.

    For more information about the Infoblox reporting solution, refer to the Infoblox NIOS Administrator Guide.

    Product Overview

    The Trinzic Reporting 1400 is a high performance network appliance that collects data from Infoblox Grid members,stores the data in the reporting database, and generates reports that provide statistical data about IPAM, DNS,DHCP, and system activities and performance. It can receive up to 5 GB of data each day. You configure and manage

    the Trinzic Reporting 1400 and view reports through an easy-to-use Infoblox GUI that works seamlessly in Windows,Linux, and Mac environments using standard web browsers. For more information about the Infoblox GUI, refer tothe Infoblox NIOS Administrator Guide.

    Key features of the Trinzic Reporting 1400 include the following:

    • Support for Grid Management and all administrative features for Infoblox IPAM, DNS, DDNS, DHCP, andIF-MAP

    • High Availability support

    • Lights Out Management support• Replaceable hard disk drives

    • Hot-swappable AC power supplies

    • Additional AC power supply for a redundant 1+1 configuration

    • Alternative system configurations for the support of copper or fiber SFP/SFP+ 1GbE/10GbE interfaces

    The Trinzic Reporting 1400 appliance comprises hot-swappable power supplies, replaceable hard disk drives, andoptional network interfaces. It is a Class A digital appliance per FCC regulations, and RoHS and WEEE compliant.

  • 8/17/2019 Trinzic Reporting 1400 Guia de Instalacao

    6/28

    Introduction

    6 Infoblox Installation Guide

    Hardware Components

    The Trinzic Reporting 1400 is a 1-U platform that you can mount in a standard equipment rack using the mountingbrackets and bolts that ship with the appliance. For information about rack mounting, see Rack Mounting on page13. 

    Front Panel

    The front panel components include the LCD (liquid crystal display) panel and navigation buttons, communicationports, and LEDs, as shown in Figure 1. For explanations of the Ethernet port LEDs, and console and Ethernet portconnector pin assignments, see Ethernet Port LEDs and Connector Pin Assignments on page 8.

    Figure 1 Trinzic Reporting 1400, Front View 

    The front panel components are described in Table 1.

    Table 1 Front Panel Components

    Component Description

    LCD Panel An LCD screen that displays network settings, software version number, hardware serialnumber, and software licenses. You can view and configure the IP address, netmask, andgateway for the LAN1 port.

    NavigationButtons

    Buttons that allow you to enter the IP address, subnet mask, and gateway of the LAN1port through the LCD. Use the Up and Down arrow buttons to specify numbers and theLeft and Right buttons to navigate across digits. You must specify whether to save input(Accept) or discard it (Cancel). Selecting Cancel at any time returns you to the previous

    entry. Entering Accept on the third screen returns you to the system status screen.

    USB Port

    LCD Panel

    Navigation

    Button

    Console

    Port

    MGMTPort

    LAN1

    Port

    HA Port (disabled)

    LAN2

    Port

    PowerLED

    On/OffSwitch

    UID Button

    StatusLED

     AlarmLED

    IPMIPort

    http://../Trinzic_1400/install.pdfhttp://../Trinzic_1400/install.pdfhttp://../Trinzic_1400/install.pdfhttp://../Trinzic_1400/install.pdfhttp://../Trinzic_1400/install.pdf

  • 8/17/2019 Trinzic Reporting 1400 Guia de Instalacao

    7/28

    Hardware Components

    For the Trinzic Reporting 1400 Appliance 7

    On/Off Switch A power switch to turn the power supply of the appliance on and off. Use a small bluntobject, such as a paper clip, to perform the task.

    IPMI Port Dedicated Ethernet port used for LOM (Lights Out Management) with specific releases ofNIOS. Ensure that the IPMI port is properly connected to the network before you configureLOM through the Infoblox GUI for remote management.

    USB Port Reserved for future use.

    Console Port A male DB-9 serial port for a console connection to change basic configuration settingsand view basic system functions through the CLI (command line interface). Use theserial cable and connection adapters that ship with the appliance to make a consoleconnection to this port.

    Only a properly grounded USB-to-Serial dongle is allowed to connect to the serialconsole port. If the dongle is connected to a laptop, this laptop must be groundedproperly as well. Failure to do so may result in damage to the serial console port of theInfoblox appliance. Infoblox is not responsible for such damage.

    MGMT Port A 10/100/1000-Mbps gigabit Ethernet port that you can use for appliance managementor DNS service. You can enable the MGMT port and define its use through the GUI afterthe initial setup.

    HA Port High Availability system failover port. The HA port is disabled. The Trinzic Reporting1400 does not operate in high availability (HA) mode.

    LAN1 Port A 10/100/1000-Mbps gigabit Ethernet port that connects the appliance to the network.

     You must use the LAN1 port to set up the appliance initially. It handles all traffic if you donot enable the MGMT and LAN2 ports. The passive node in an HA pair uses this port tosynchronize the database with the active node.

    LAN2 Port A 10/100/1000-Mbps gigabit Ethernet port that connects the appliance to the network.The LAN2 port is not enabled by default. You can enable the LAN2 port and define its usethrough the GUI after the initial setup.

    UID Button The unit identification button. When you press the UID button, the LCD panel on the front

    panel blinks and the UID LED on the rear panel glows blue. In a rack environment, the UIDfeature enables easier location of a server when moving between the front and rear of therack. You can also identify the appliance through the Infoblox GUI and CLI command.

    Status LED Reserved for future use.

    Power LED An LED that glows blue when there is power to the appliance. When it is dark, theappliance is not receiving power.

    Alarm LED Reserved for future use.

    Component Description

  • 8/17/2019 Trinzic Reporting 1400 Guia de Instalacao

    8/28

    Introduction

    8 Infoblox Installation Guide

    Ethernet Port LEDs

    To see the link activity and connection speed of an Ethernet port, you can look at its Activity and Link LEDs. Figure 2 shows the status the LEDs convey through their color and illumination (steady glow or blinking).

    Figure 2 LEDs

    Connector Pin Assignments

    An Infoblox appliance has three types of ports on its front panel:

    • USB port (reserved for future use)

    • Male DB-9 console port• Three (3) RJ-45 10Base-T/100Base-T/1000Base-T auto-sensing gigabit Ethernet ports (HA interface disabled)

    — Available 10-gigabit Ethernet SFP+ configuration or 1-gigabit Ethernet SFP configuration (see 10 GigabitEthernet Support  section)

    The DB-9 and RJ-45 connector pin assignments are described in Figure 3. The DB-9 pin assignments follow theEIA232 standard. To make a serial connection from your management system to the console port, use the RJ-45rollover cable and two female RJ-45-to-female DB-9 adapters that ship with the appliance. RJ-45 pin assignmentsfollow IEEE 802.3 specifications. All Infoblox Ethernet ports are auto-sensing and automatically adjust to standardstraight-through and cross-over ethernet cables.

    Link    ActivityLabel Color Port Status

     Activity Blinking Green Link is Up and Active (SFP+ only)

    Steady Yellow Link is up but inactive

    Blinking Yellow Link is up and active

    Dark Link is down

    Link Steady Blue 10000 Mbps (SFP+ only)

    Steady Amber 1000 Mbps

    Steady Green 100 Mbps

    Dark 10 Mbps

  • 8/17/2019 Trinzic Reporting 1400 Guia de Instalacao

    9/28

    Hardware Components

    For the Trinzic Reporting 1400 Appliance 9

    Figure 3 Connector Pin Assignments

    10Base-T Ethernet and 100Base-T fast Ethernet use the same two pairs of wires. The twisted pair of wiresconnecting to pins 1 and 2 transmit data, and the twisted pair connecting to pins 3 and 6 receive data. For1000Base-T connections, all four twisted-pair wires are used for bidirectional traffic.

    21 3 4 5

    6 7 8 9

    Link    Activity

    78 6 5 34 2 1

    DB-9 Connector Pin Assignments

    Pin 10Base-T100Base-T  Signal

    1000Base-TSignal

    T568A  Straight-ThroughWire Color 

    T568B Straight-ThroughWire Color 

    1 Transmit + BI_DA+ White/Green White/Orange

    2 Transmit - BI_DA- Green Orange

    3 Receive + BI_DB+ White/Orange White/Green

    4 (not used) BI_DC+ Blue Blue

    5 (not used) BI_DC- White/Blue White/Blue

    6 Receive - BI_DB- Orange Green

    7 (not used) BI_DD+ White/Brown White/Brown

    8 (not used) BI_DD- Brown Brown

    Male DB-9 Console Port

    RJ-45 Ethernet Ports

    Pin Signal Direction

    1 (not used)

    2 Receive Input

    3 Transmit Output

    4 DTE Ready Output

    5 Ground —

    6 DCE Ready Input

    7 RTS (Request to Send) Output

    8 CTS (Clear to Send) Output

    9 (not used)

    (Looking into the consoleport on an Infoblox

    appliance)

    RJ-45 Connector Pin Assignments

    (Looking into RJ-45ethernet ports on anInfoblox appliance)

    Legend: BI_D = bidirectional; A, B, C, D = wire pairings

  • 8/17/2019 Trinzic Reporting 1400 Guia de Instalacao

    10/28

    Introduction

    10 Infoblox Installation Guide

    10 Gigabit Ethernet Support

    To ensure connectivity to 10 Gigabit networking infrastructure, Infoblox offers versions of the TR-1400 (TrinzicReporting appliance) providing three active 10-Gigabit Ethernet (10GbE) interfaces accepting SFP+ transceivermodules for 10GbE RJ-45 copper or for 10GbE optical connectivity. An example with fiber transceivers is shown inFigure 4.

    Figure 4 Trinzic Reporting 1400, Front View with Four SFP/SFP+ Interfaces (three active)

    Infoblox also offers versions of the TR-1400 appliance providing three active 1-Gigabit Ethernet (1GbE) interfacesthat accept SFP transceiver modules for 1GbE optical connectivity.

    In select configurations for the Trinzic Reporting 1400, the Infoblox 1GbE SFP or 10GbE SFP+ ports replace thefunctionality in the original system MGMT, LAN1, and LAN2 ports, thereby disabling the built-in MGMT, LAN1, andLAN2 ports. 10GbE support accepts Infoblox-provided SFP+ 10GbE Short Range and Long Range transceivers, CiscoSFP+ Direct Attach 10GSFP+Cu, or HP HPJ9283B SFP+ Direct Attach 10GSFP+Cu transceivers.

     You may mix media types in the set of ports (e.g., copper interfaces and fiber interfaces).

    SFP and SFP+ transceivers may be used in a mixed configuration in the 10GbE system. One possible use case

    involves installing 10GbE SR SFP+ transceivers in the LAN1 and LAN2 ports for the Trinzic Reporting 1400 appliance,and installing a 1GbE SFP copper transceiver in the MGMT interface.

    See the section Replaceable Units and SFPs, for specific information on part numbers, availability, and devicecompatibility.

    Rear Panel

    The rear panel components include the power connectors, hard disk drives, fans, air vent, and the UID LED, as

    shown in Figure 5.

    USB Port

    LCD Panel

    NavigationButton

    ConsolePort

    MGMT, LAN1,and LAN2 Ports

    (disabled with alternate port configuration)

    PowerLED

    On/OffSwitch

    1GbE or 10GbE interfaces: 

    MGMT-LAN1-(HA)-LAN2  in order from left to right (HAdisabled)

    UID ButtonStatusLED

     AlarmLED

    IPMI Port for Lights Out Management (LOM)

    http://../Trinzic_1400/replacing_field_units.pdfhttp://../Trinzic_1400/replacing_field_units.pdf

  • 8/17/2019 Trinzic Reporting 1400 Guia de Instalacao

    11/28

    System, Environmental, and Power Specifications

    For the Trinzic Reporting 1400 Appliance 11

    Figure 5 Trinzic Reporting 1400, Rear View 

    Table 2 Rear Panel Components

    System, Environmental, and Power Specifications

    System specifications describe the physical characteristics of each appliance. Environmental specificationsdescribe the temperature and moisture limits it can withstand. Power specifications describe the electrical rangewithin which the appliance circuitry can operate.

    Component Description

    Hard Disk Drives Two (2) Infoblox data storage devices in a RAID array.

    Drive Indicators LEDs that flash green to indicate the hard drive is processing data.

    Fans A fan system (5 fans total) to help maintain optimum operating temperature. Do notobstruct.

    UID LED Blue = UID is activated through pressing the UID button on the appliance Blinking Blue = UID is activated through the Infoblox GUI or CLI command Dark = UID is deactivated

    Note: When UID is activated, the LCD on the front panel blinks at the same time.

    Power Supply Each power supply has a power outlet for connecting the appliance to a standard ACpower source.

    Power LED The power indicator is green if the power supply has power and is dark if it does nothave power.

    Air Vent An air vent that allows warm air to flow out of the appliance. Do not obstruct.

     Air Vent

    Hard Disk

    Drives Fan

    PowerSupply

    OptionalPower

    Supply

    Redundant Power Outlets

    Fan Fan UID LED

    Drive

    Indicators

    PowerLED

  • 8/17/2019 Trinzic Reporting 1400 Guia de Instalacao

    12/28

    Introduction

    12 Infoblox Installation Guide

    System Specifications• Form Factor: 1-U rack-mountable appliance

    • Dimensions: 1.73” H x 17.36” W x 17.2” D (4.4 cm H x 44.1 cm W x 43.7 cm D)

    • Weight: Approximately 24 to 28 pounds (10.9 to 12.7 kg)

    • Ethernet Ports: MGMT, LAN1, LAN2 – auto-sensing 10Base-T/100Base-T/1000Base-T 

    • Serial Port: DB-9 (9600/8n1, Xon/Xoff)

    • USB Port: USB2.0/1.1 compliant

    • LCD Panel: LCD (liquid crystal display) with input buttons

    Environmental Specifications

    • Operating Temperature: 41 to 104 degrees F (5 to 40 degrees C)• Storage Temperature: -13 to 158 degrees F (-25 to 70 degrees C)

    • Operating relative Humidity: 10% to 90% (non-condensing)

    Electrical Power Specifications• AC Power Supply: Dual input, 450 Watts

    — Input Voltage.: 90 – 264VAC

    — Input Frequency: 47 – 63 HZ— Input Current: 4A max at 230V

    — Inrush Current: 20A max at 230V

    — Power Factor: > 0.94/230V 50 Hz

  • 8/17/2019 Trinzic Reporting 1400 Guia de Instalacao

    13/28

    For the Trinzic Reporting 1400 Appliance 13

    Installing an Appliance

    Follow these instructions to rack mount the Trinzic Reporting 1400 appliance, connect it to a power source, andcable it to a network. Before proceeding, review the Infoblox Safety Guide and follow the necessary precautions.

    Rack Mounting

    The Trinzic Reporting 1400 appliance mounts into a standard 19” (48 cm) equipment rack. The appliance ships with

    accessory kits that contain the following: a pair of rack slide brackets and chassis slide rails, a pair of rack ears,eight (8) 10-32 screws, and eight (8) 8-32 screws. To mount the appliance to an equipment rack, you also need a#2 screwdriver with a cross-headed tip. There are two ways to rack mount the Trinzic Reporting 1400:

    • Two-post rack mount

    • Four-post rack mount

    Two-Post Rack Mount

    To mount the appliance to an equipment rack and secure it at the rear rack posts:1. Align the mounting holes on the rack ears with the rear-most mounting holes on each side of the chassis.

    2. Attach each rack ear on each side of the chassis with two (2) 8-32 screws, as shown in Figure 6.

    Figure 6 Rack Ears in Two-Post Rack Mount 

    3. With one person on each side, lift the appliance and position it in the equipment rack.

    4. Attach each rack ear to the equipment rack with two (2) 10-32 screws on each side.

    Rack Ear 

    I t lli A li

  • 8/17/2019 Trinzic Reporting 1400 Guia de Instalacao

    14/28

    Installing an Appliance

    14 Infoblox Installation Guide

    Four-Post Rack Mount

    To mount the appliance to an equipment rack and secure it at the front and rear rack posts:

    1. Align the mounting holes on the rack ears with the front-most mounting holes on each side of the chassis.

    2. Attach the rack ears to each side of the chassis with two (2) 8-32 screws, as shown in Figure 8 .

    3. Slide the inner chassis slide rails out of the rack slide brackets, as shown in Figure 7 .

    Figure 7 Chassis Slide Rail and Rack Slide Bracket 

    4. Align the mounting holes on the chassis slide rails with the rear-most mounting holes on each side of thechassis. Ensure that you place the chassis slide rails in the correct orientation. Otherwise, the mounting holesdo not align properly.

    5. Attach the chassis slide rails to each side of the chassis with two (2) 8-32 screws, as shown in Figure 8 .

    Figure 8 Rack Ears and Chassis Slide Rails in Four-Post Rack Mount 

    6. Select a desired location and secure the rack slide brackets to the rear posts of the equipment rack with two(2) 10-32 screws on each side of the rack, as shown in Figure 9

    Figure 9 Rack Slide Bracket Attached to the Rear Post of the Rack 

    Chassis Slide RailRack Slide Bracket 

    Rack Ear 

    Chassis Slide Rail

    Powering the Appliance

  • 8/17/2019 Trinzic Reporting 1400 Guia de Instalacao

    15/28

    Powering the Appliance

    For the Trinzic Reporting 1400 Appliance 15

    7. With one person on each side, lift the appliance and position it in front of the equipment rack.

    8. Align the chassis slide rails on the appliance with the rack slide brackets on the posts of the equipment rack.

    9. Slide the appliance into the rack slide brackets.

    10. Secure the rack ears to the rack with two (2) 10-32 screws on each side of the rack.

    Powering the Appliance

    The Trinzic Reporting 1400 appliance ships with one (1) hot-swappable AC power supply module. You can order an

    additional power supply to set up a redundant 1+1 configuration. In the 1+1 configuration, Infoblox recommends

    using the power cables shipped with the appliance to connect each power supply to separate power circuits. In

    the event of a power failure on one circuit, the appliance can then operate on the other.

    Note: If your appliance comes with one power supply and an empty module, ensure that the power supply is in thePSU #1 slot and the empty module in the #2 slot. You cannot switch them.

    To power the appliance:

    • Connect a power cable between the power connector on the back of the appliance and a properly groundedand rated power circuit that meets the provisions of the current edition of the National Electrical Code, orother wiring rules that apply to your location. Make sure that the outlet is near the appliance and is easilyaccessible.

    Cabling the Appliance to a Network

    Use one or more Category 5/6 Ethernet cables to connect the Trinzic Reporting 1400 appliance to the network.

    1. Connect an Ethernet cable from the LAN1 port on the appliance to your network switch or router.

    Figure 10 Cabling the Trinzic Reporting 1400 appliance to a Network 

    Switch orRouter 

    When cabling the reporting appliance to the network, connectan Ethernet cable from the LAN1 port on the appliance to aswitch or router.

    Infoblox Appliance

    ManagementSystem

    Cabling the Appliance to a Network

  • 8/17/2019 Trinzic Reporting 1400 Guia de Instalacao

    16/28

    Cabling the Appliance to a Network

    For the Trinzic Reporting 1400 Appliance 16

    Note: By default, an Infoblox appliance automatically negotiates the optimal connection speed andtransmission type (full or half duplex) on the physical links between its communication ports and the Ethernet

    ports on a connecting switch. If the appliance fails to auto-negotiate the optimal settings, see the InfobloxNIOS Administrator Guide  for steps you can take to resolve the problem.

    2. Use the Infoblox GUI to access the Infoblox reporting appliance from a management system. Through the GUI,you can set up and administer the appliance. For management system requirements and access instructions,see Accessing the Appliance on page 17.

  • 8/17/2019 Trinzic Reporting 1400 Guia de Instalacao

    17/28

    For the Trinzic Reporting 1400 Appliance 17

     Accessing the Appliance

    The management system is the computer from which you configure and monitor the Infoblox appliance. You canaccess the appliance from the management system remotely across an Ethernet network or directly through a serialcable.

    After completing the steps in Cabling the Appliance to a Network  on page 15, you can make an HTTPS connection tothe appliance and access the Infoblox GUI using one of the supported browsers.

    Alternatively, you can make an SSHv2 connection and access the CLI through an SSHv2 client. You can also access

    the CLI by connecting a serial cable directly from the console port of a management system to the console port onthe appliance, and then using a terminal emulation program.

    The management system must meet the following requirements to operate an Infoblox appliance.

    Table 3 Software and Hardware Requirements for the Management System

    Management System Software RequirementsManagement System HardwareRequirements

    Infoblox GUI Access

    • Microsoft Windows 8®: Microsoft Internet Explorer® 10.x*;Mozilla Firefox 21.x, 16.x, and 10.x; Google Chrome 27.x, 22.x,and 16.x

    • Microsoft Windows 7®: Microsoft® Internet Explorer® 8.x and9.x, Mozilla Firefox 7.x, 8.x and 16.x or Google Chrome 10.x,16.x and 22.x

    • Microsoft Windows XP® (SP2+): Microsoft Internet Explorer® 7.x and 8.x, Mozilla Firefox 3.6.x, 7.x, 10.x and 16.x, or GoogleChrome 10.x, 16.x and 22.x

    • Red Hat® Enterprise Linux® 6.x: Mozilla Firefox 7.x, 10.x and16.x or Google Chrome 10.x, 16.x and 22.x

    • Red Hat® Enterprise Linux® 5.x: Mozilla Firefox 7.x, 10.x and

    16.x or Google Chrome 10.x, 16.x and 22.x• Apple Mac OS® X 10.7.x: Safari 5.x, Mozilla Firefox 7.x, 10.x and

    16.x or Google Chrome 10.x, 16.x and 22.x

    • Apple Mac OS® X 10.6.x: Safari 5.x, Mozilla Firefox 7.x, 10.x and16.x or Google Chrome 10.x, 16.x and 22.x

    CLI Access

    • Secure Socket Shell (SSH) client that supports SSHv2

    • Terminal emulation program.

    • Minimum System: 500 MHz CPU with 256 MB RAMavailable to the Infoblox GUI, and256 Kbps connectivity to an Infobloxappliance

    • Recommended System: 

    1 GHz (or higher) CPU with 512 MBRAM available for the Infoblox GUI, andnetwork connectivity to an Infobloxappliance

    • Monitor Resolution:Minimum: 1024 x 768

    Recommended: 1280 x 800 or better

    Accessing the Appliance

  • 8/17/2019 Trinzic Reporting 1400 Guia de Instalacao

    18/28

    g pp

    18 Infoblox Installation Guide

    Connecting to the Appliance

    Before you can configure the Trinzic Reporting appliance through the Infoblox GUI, you must be able to make anetwork connection to it. You must use the LAN1 port to connect to the appliance. The default network settings ofthe LAN1 port are 192.168.1.2/24 with a gateway at 192.168.1.1 (the MGMT and LAN2 ports do not have defaultnetwork settings). To change these settings to suit your network, use either the LCD or the console port.

    LCD

    The Infoblox appliance has an LCD and navigation buttons on its front panel. At startup, the Infoblox logo appearsin the LCD on the front panel of the appliance. Then the LCD scrolls repeatedly through a series of display screens.

    1. To change the network settings from the default, press one of the navigation buttons.The LCD immediately goes into input mode.

    2. Use the navigation buttons to enter the IP address, netmask, and gateway for the LAN1 port.

     You can disable LCD input functionality. To disable the LCD, refer to the Infoblox NIOS Administrator Guide.

    Console Port 

    The Infoblox appliance has a male DB-9 console port on the front panel. You can log in to the appliance through thisport and specify initial network settings using the Infoblox CLI.

    Note: Only a properly grounded USB-to-Serial dongle is allowed to connect to the serial console port. If the dongleis connected to a laptop, this laptop must be grounded properly as well. Failure to do so may result in damage tothe serial console port of the Infoblox appliance. Infoblox is not responsible for such damage.

    1. Connect a console cable from the console port of the management system to the console port of the Infoblox

    appliance.2. Using a serial terminal emulation program such as Hilgraeve Hyperterminal® (provided with Windows® 

    operating systems), launch a session. The connection settings are:— Bits per second: 9600 — Stop bits: 1— Data bits: 8 — Flow control: Xon/Xoff  — Parity: None

    3. Log in using the default user name and password admin and infoblox . User names and passwords arecase-sensitive.

    4. To change the network settings from the default, enter the set network command. Then enter informationas prompted to change the IP address, netmask, and gateway for the LAN1 port.

    Infoblox > set network

    NOTICE: All HA configuration is performed from the GUI. This interface is used only toconfigure a standalone node or to join a grid.

    Enter IP address: LAN1 port  IP address

    Enter netmask: [Default: 255.255.255.0]: netmask

    Enter gateway address [Default: n.n.n.1]: gateway IP addressBecome grid member? (y or n): n

    After you confirm your network settings, the appliance automatically restarts.

    Specifying Appliance Settings

  • 8/17/2019 Trinzic Reporting 1400 Guia de Instalacao

    19/28

    For the Trinzic Reporting 1400 Appliance 19

    Specifying Appliance Settings

    When you make the initial HTTPS connection to the Infoblox appliance, you see the Setup Wizard, whichguides you through the basic deployment of the appliance on your network.

    A Grid is a group of two or more Infoblox appliances that share sections of a common, distributed, built-indatabase and which you configure and monitor through a single, secure point of access—the Grid Master. Toset up a Grid, you must configure a single or HA Grid Master and at least one Grid member, which can also bea single appliance or an HA pair.

    Note: Even though you configure the reporting appliance as a Grid member, you cannot configure it as an HA

    pair in the Grid.

    The following instructions guide you through the wizard and include worksheets where you can note yourappliance and network settings. After you complete the wizard for the reporting appliance, you can configurethe Grid members to transmit data to the reporting appliance. The Trinzic Reporting 1400 appliance comeswith the Reporting license installed. You are not required to install the reporting license on the TrinzicReporting 1400 appliance. However, reporting service on the Grid is disabled by default. You must enablereporting service on the Grid (for all members) or on individual Grid members so that data is transmitted tothe Trinzic reporting appliance. For information about how to configure Grid reporting properties and enablereporting service, refer to the Infoblox NIOS Administrator Guide.

    1. Open an Internet browser window and enter https: IP address or hostname of your reporting appliance>.

    2. Accept the certificate when prompted.

    A certificate warning appears during the login process. This is normal because the NIOS appliance generatesa self-signed certificate when it first starts, and your browser does not have a trusted CA certificate or acached NIOS appliance server certificate (saved from an earlier connection) to authenticate the NIOS

    appliance certificate. Also, the hostname in the default certificate is www.infoblox.com, which is unlikely tomatch the hostname of your NIOS appliance. Consequently, messages appear warning that the certificate isnot from a trusted certifying authority and that the hostname on the certificate is either invalid or does notmatch the name of the site that sent the certificate. Either accept the certificate just for this session or save itto the certificate store of your browser.

    To eliminate the certificate warning, generate a new self-signed certificate or import a third-party certificatewith a common name that matches the FQDN (fully-qualified domain name) of the appliance. This is a verysimple process. For information about certificates, refer to the Infoblox NIOS Administrator Guide.

    3. Log in using the default user name and password admin and infoblox .

    Note: User names and passwords are case-sensitive.

    4. Read the Infoblox End-User License Agreement and click I Accept to proceed.

    5. The Setup Wizard opens, and you can enter basic network and deployment settings.

    Determine how you want to deploy the appliance, and then use the following worksheets to note the networksettings that you want to enter on the wizard screens.

    Accessing the Appliance

  • 8/17/2019 Trinzic Reporting 1400 Guia de Instalacao

    20/28

    20 Infoblox Installation Guide

    Use the following worksheet when configuring the reporting appliance:

    On the last screen of the wizard, click Finish. The Infoblox GUI application restarts.

    Settings Enter your information here

    Grid NameShared Secret Host Name

    Grid Master’s IP Address

    LAN1 Port IP Address and Netmask

    Gateway IP Address

    Port Settings

    NTP Server IP Address

    Infoblox GUI

  • 8/17/2019 Trinzic Reporting 1400 Guia de Instalacao

    21/28

    For the Trinzic Reporting 1400 Appliance 21

    Infoblox GUI

     You can view reporting data and configuration settings and make configuration changes through the Reporting tabof the Infoblox GUI.

    Figure 11 Infoblox GUI Overview 

    Finder Panel Workspace Toolbar 

    Global SearchReporting Tab

    Help Panel

    Accessing the Appliance

  • 8/17/2019 Trinzic Reporting 1400 Guia de Instalacao

    22/28

    22 Infoblox Installation Guide

    Infoblox CLI

    The Infoblox CLI allows you to configure and monitor the appliance using a small set of Infoblox commands. Thereare some tasks, such as resetting the appliance, that you can only do through the CLI. You can access the InfobloxCLI through a direct console connection from your management system to the Infoblox appliance. (For moreinformation, see Console Port  on page 18.) You can also enable remote console access—that is, SSHv2 (Secure Shellversion 2) access—through the Infoblox GUI or CLI, and then access the CLI from a remote location using an SSHv2client. (For more information, refer to the Infoblox NIOS Administrator Guide .)

    Using CLI Help

     You can display a list of available CLI commands by typing  help at the command prompt. For example:Infoblox > help

    ? Display help

      delete Delete files

      dig Perform a DNS lookup and print the results

      exit Exit command interpreter

      help Display help

      ping Send ICMP ECHO

      quit Exit command interpreter

      reboot Reboot device

      reset Reset system settings

      set Set current system settings

      show Show current system settings

      shutdown Shutdown device

      traceroute Route path diagnostic

      ddns_add Send DDNS update to add a record

      ddns_delete Send DDNS update to delete a record

      rotate Rotate files

    To view an in-depth explanation of a CLI command and its syntax, type help command  after the commandprompt. For example:

    Infoblox > help rotateSynopsis:

    rotate log [ syslog | debug | audit | ifmapserver ]

      rotate file groupname filename [ filename2, filename3, ...]

    Description:

    Rotates the specified log file, up to 10 previous.

      logfiles will be preserved

    The two main groups of Infoblox CLI commands are set and show. To see the complete list of the set commands,enter help set after the command prompt. Likewise, to see a complete list of the show commands, enter helpshow. For information about the CLI commands, refer to the Infoblox CLI Guide.

  • 8/17/2019 Trinzic Reporting 1400 Guia de Instalacao

    23/28

    For the Trinzic Reporting 1400 Appliance 23

    System Device Replacement

    The Trinzic Reporting 1400 provides several replaceable units in the system:

    • Hard disk drives

    • AC power supplies

    All replaceable units must be replaced with parts of the same specifications as described below. For parts andreplacements, contact your Infoblox field representative or Infoblox technical support.

    Managing the Disk Subsystem

    The Trinzic Reporting 1400 uses a RAID (Redundant Array of Independent Disks) 1 array to provide redundant datastorage with recovery features in the event of disk failures. The disk array is completely self managed. There are nomaintenance or special procedures required to service the disk subsystem.

    RAID 1 uses two disk drives for mirroring so that each disk in the logical volume is fully redundant.

    Figure 12 RAID 1 Array Configuration

    Evaluating the Status of the Disk Subsystem

     You can monitor the disk subsystem through the Infoblox GUI, the scrolling front panel LCD display, and the LEDs

    next to the disk drives. In addition, you can monitor the disk status by using the CLI commandshowhardware_status.

    To see a detailed status report, log in to the Infoblox GUI and from the Grid tab, select the Grid Manager  tab ->Members tab -> reporting member , and then click the Detailed Status icon. (For more information about the DetailedStatus panel, refer to the Infoblox NIOS Administrator Guide.)

    The color of the RAID icon indicates the status of the RAID array on the Trinzic Reporting 1400.

    Color Meaning  

    Green The RAID array is in an optimal state.

    Disk 1Primary

    Disk 1Backup

    RAID 1

    System Device Replacement

  • 8/17/2019 Trinzic Reporting 1400 Guia de Instalacao

    24/28

    24 Infoblox Installation Guide

    In the event of a disk failure, you must replace the failed disk with one that is qualified and shipped from Infobloxand has the same disk type as the other disk in the array. The appliance displays information about mismatcheddisks in the Detailed Status panel. The disk type must be an IB-Type 5.

    Hard Disk Drive Replacement

    Use the following procedure to remove a spinning disk:

    1. Power down the appliance before replacing the hard disk drive.

    2. Press the release button to unlatch the disk.

    3. Use the catch-release lever to pull the disk about two cm (one inch) to disengage contact, as indicated in

    Figure 13.

    Figure 13 Pull the catch-release lever to remove hard drive

    4. Remove the disk, extract it from its carrier and handle it with care. Do not drop the disk or ship it looselyin a carton.

    5. Securely mount the replacement disk in the drive carrier and replace the carrier in the system.

     Yellow A new disk was inserted and the RAID array is rebuilding.

    Red The RAID array is degraded. At least one disk is not functioning properly. The GUI lists the disksthat are online. Replace only the disk that is offline.

    Color Meaning  

    Catch-release lever 

    Release button(Red)

    Changing AC Power Supplies

  • 8/17/2019 Trinzic Reporting 1400 Guia de Instalacao

    25/28

    For the Trinzic Reporting 1400 Appliance 25

    Note: IP settings and basic network configurations, such as the gateway address, netmask, Grid secret andGrid name, are saved and restored when you replace a failed disk drive.

    Changing AC Power Supplies

    Note: Before changing the power supply, make sure it is securely cabled. An apparently failed power supply maysimply be improperly connected to its power source.

    The Trinzic Reporting 1400 ships with one AC power supply. When the power supply fails for any reason, theInfoblox GUI displays a power supply alarm. The Grid Status widget on the Dashboard of the GUI also displays anerror. The appliance sends an email notification and reports an SNMP trap. Figure 14 illustrates the process ofreplacing an AC power supply.

    Each power supply weighs about one pound (0.454 kg). The faceplate of the power supply contains a power LED anda power switch. Each AC power supply provides a dedicated power outlet.

    Note: If your appliance comes with one power supply and an empty module, ensure that the power supply is in thePSU #1 slot and the empty module in the #2 slot. You cannot switch them.

    Figure 14 Removing a Trinzic Reporting 1400 AC Power Supply 

    Handle

    Catch-release lever 

    (black)

    Changing AC Power Supplies

  • 8/17/2019 Trinzic Reporting 1400 Guia de Instalacao

    26/28

    For the Trinzic Reporting 1400 Appliance 26

    To replace the Trinzic Reporting 1400 AC power supply, do the following:

    1. Turn off the power supply.

    2. Disconnect the AC power cable from the power outlet.

    3. Gently press the black catch-release lever toward the handle, grip the power supply handle, and pull thepower supply unit out of the chassis as illustrated in Figure 14.

    4. Place the replacement power supply into the bay and push it forward until it is fully seated in the chassis.The catch-release lever will gently click into place.

    5. Reconnect the power cable.

    6. Turn on the power supply. If it is fully seated, powered on, and operating properly, the LED glows steadygreen.

     You can order an additional power supply to set up a redundant 1+1 configuration, as shown in Figure 15. Thepower supplies are “hot-swappable,” so you can remove or replace one power supply without interruptingappliance operation and network services.

    When the appliance contains two functioning power supplies, they share the power load. If one power supply fails,the other assumes the full load automatically and the appliance sends a system alarm. This configurationminimizes the chance of system failure due to failure of an individual power supply.

    Figure 15 Trinzic Reporting 1400 with Dual AC Power Supplies

    Replaceable Units and SFPs

  • 8/17/2019 Trinzic Reporting 1400 Guia de Instalacao

    27/28

    For the Trinzic Reporting 1400 Appliance 27

    Replaceable Units and SFPs

    Table 4 lists field replaceable units and orderable parts for the Trinzic Reporting 1400 appliance. It specifiescompatibility of the units and their part numbers. Contact your Infoblox field representative or Infoblox TechnicalSupport for more information.

    Table 4 Field-Replaceable Units and Orderable Parts

    1 Infoblox no longer ships the T-1400-DISK-HDD300 and T-1400-DISK-HDD600 disk drives in currently shippingsystems. You may continue to purchase replacement and spare FRU T-1400-DISK-HDD300 andT-1400-DISK-HDD600 disk drives from Infoblox.

    2 Consult Knowledge Base articles 17748 and 21807 from Infoblox Support ( http://support.infoblox.com ) forupdated information regarding Rev 1 and Rev 2 platforms for all Trinzic appliances.

    Infoblox supports SFP/SFP+ transceivers of various types for 1GbE and 10GbE networking applications. Table 5 liststhe Ethernet SFP transceivers that are compatible with Infoblox Ethernet SFP/SFP+ interfaces and basic guidelinesfor compatibility.

    Table 5 Transceivers for 1GbE SFP and 10GbE SFP+ Support 

    Option orField-Replaceable Unit

    Part Number Type TR-1400

    Trinzic 1400 Series AC PSU T-1400-PSU-AC FRU and orderable option Y  

    Trinzic 1400 Series single

    hard disk, 600 GB

    T-1400-DISK-HDD600 FRU only1 2   Y 

    Trinzic 1400 Series single

    hard disk, 1.0 TB

    T-1400-R2-DISK-HDD1000 FRU only2  Y 

    Field-Replaceable Unit Part Number Type TR-1400

    Infoblox SFP+ Long Range

    10GbE LR fiber Transceiver

    IB-SFPPLUS-LR FRU only Y  

    Infoblox SFP+ Short Range

    10GbE SR fiber Transceiver

    IB-SFPPLUS-SR FRU only Y 

    Infoblox SFP 1GbE SX Fiber IB-SFP-SX FRU only Y  

    Infoblox SFP 1GbE Copper

    Interface Transceiver

    IB-SFP-CO FRU only Y  

    Finisar SFP 1GbE LR Fiber

    Single-Mode Transceiver

    Finisar FTLF1318P3BTL Not sold by Infoblox 

    Contact your distributorfor availability

     Y 

    Replaceable Units and SFPs

  • 8/17/2019 Trinzic Reporting 1400 Guia de Instalacao

    28/28

    For the Trinzic Reporting 1400 Appliance 28

    Cisco SFP+ 10GbE Copper

    Direct Attach (10GSFP+Cu)

    Cable

    Cisco SFP-H10GB-CU5M Not sold by Infoblox 

    Contact your distributor

    for availability

     Y 

    HP SFP+ 10GbE Copper

    Direct Attach (10GSFP+Cu)

    Cable

    HPJ9283B Not sold by Infoblox 

    Contact your distributor

    for availability

     Y 

    Field-Replaceable Unit Part Number Type TR-1400