Upload
vokien
View
230
Download
2
Embed Size (px)
Citation preview
1
FINNED TUBE RADIATIONMODELSWF SERIES
ATXH0508
TM WF SeriesFinned Tube Radiation
HEAT TRANSFER DIVISION
TM
TM
FINNED TUBE RADIATIONMODELS
2
WF SERIES
ATXH0508
TOP
WF-2XTOPOUTLET - FS
FREESTANDING
WF-2A,
WF-3XFRONTOUTLET
WF-4X
ENCLOSURECOMPACT
FORFLATJOGGLE
WF-5A
TOPOUTLET
BARTOP
FLATFORGRILLE
WF-6X
JOGGLE
FOR
JOGGLEFLAT
EXPANDEDMETAL
WF-7A
- FS AND- C BOTTOM.
AVAILABLE ONWF-3, WF-6,
BAR GRILLE
TYPE A
BOTTOMOPEN SLOPED
BOTTOM
TYPE B BOTTOM
SLOPE
WF-1X
TYPE C
TO
WITHFLOOR
FRONTINLET
3A or
X DENOTES BOTTOM TYPE A, B or C
6A
OPENINVERTED
OUTLET GRILLE
GRILLE
INLET INLET
GRILLE
NOTE:
3
WF SERIES
ATXH0508
TM
ENCLOSURES
Airtex standard enclosures are produced in the following styles: Slope Top (WF-1), Flat Top (WF-2) and Front Outlet (WF-3). Enclosure inlets can be supplied with Open Bottom (Type A), Slope bottom (Type B) and Front Inlet Grille (Type C). Models are available in a variety of heights from 6” (152mm) to 36” (914mm) with lengths from 2’-0” (610mm) to 6’-0” (1829mm) increments.
In addition to standard enclosures, Airtex can provide, upon request, custom designed models in a size, metal type, gauge and paint fi nish to suit any desired application.
ACCESSORIES
For ease of installation and design continuity, Airtex manufactures brackets, element hangers, joggle strips, end caps, inside and outside corners, laps, access doors, pilaster kits and manual dampers, Manual dampers must be factory installed.
COPPER-ALUMINUM ELEMENT
The element is constructed of 1 1/4” (32mm) nominal (1 3/8” (35mm) O.D.) or 3/4” (19mm) nominal (7/8” (22mm) O.D.), seamless copper tubing. The aluminum fi ns are 4” (102mm) x 4” (102mm), for either tube diameter (optional 3 1/4” (83mm) x 2 1/2” (64mm) available with 3/4” (19mm) nominal tube, with a stamped pattern which provides strength and rigidity. Integral collars provide uniform spacing and maximum heat transfer. Permanent contact between fi n and tube is obtained by mechanical expansion of the tube. Tube ends are suitable for standard sweat fi ttings. These elements are manufactured with 50 fi ns/ft (164 fi ns/m), with nominal lengths from 2’-0” (610mm) to 7’-6” (2286mm) in 6” (152mm) increments.
COPPER-ALUMINUM ELEMENT
2" 2"(50) (50)
NOMINAL LENGTH
FINNED TUBE RADIATIONGENERAL INFORMATION
4ATXH0508
TM
6"(152)
OR
12"(305)
(67)2 5/8"
6"(152)
OR
12"(305)
2 5/8"(67)
2 5/8"(67)
(305)
(152)6"
OR
12"
ELEMENT ROWSSTEAM CAP. / FT
BTU/HR/FT
HOT WATER CAPACITY BTU/HR/FT AT 65°F AIRAVERAGE WATER TEMPERATURE °F
1 1/4"COPPER TUBE
4" X 4"ALUMINUM FIN
50 FINS/FT
1
3 (12" CENTERS)
2 (6" CENTERS)
4930
3880
3550
2910
1740 1830
5180
4070
3730
3060
1650
4680
2760
3690
3370
1500
4240
2500
3340
3050
1360
3850
2270
3030
2770
1200
3400
2010
2680
2450
1060
3010
1780
2370
2170
220 210 200 190 180 170
ELEMENT
32mmCOPPER TUBE
102mm X 102mm
ALUMINUM FIN164 FINS/M
STEAM CAP. / m6.89 kPa at 18°C
kW/m
3.73
4.74
ROWS
2.80
3.41
1.67
4.08
3.213.91
4.98
3.55
4.50 3.27
2.582.91
3.70
2.28
2.89
HOT WATER CAPACITY kW/m at 18°C AIRAVERAGE WATER TEMPERATURE °C
2.40
2.93
1.44
104
3.59
2.94
1.76
9399
2.65
3.24
1.59
82
1.93
2.36
1.15
88
2.18
2.66
1.31
77
1.71
2.09
1.02
AIR
3 (6" CENTERS)
3 (305mm CTRS)
3 (152mm CTRS)
1
2 (12" CENTERS)
2 (152mm CTRS)
2 (305mm CTRS)
1 PSI AT 65°F AIR
ME
TRIC
IMP
ER
IAL
CAPACITIES OF ELEMENTS WITHOUT ENCLOSURES
NOTES: Capacities are based on 3 fps (0.9 m/s) water velocity. 3/4” x 4” x 4” (19mm x 102mm x 102mm) Cu/AL element has the same capacity as 1 1/4” x 4” x 4” (32mm x 102mm x 102mm) Cu/AL element for the same fl ow rate (GPM (L/s)) For capacity correction see page 81. Refer to fl ow chart on page 86 for pressure drop data.
FINNED TUBE RADIATIONDIMENSIONS & CAPACITIESELEMENT
WITHOUT ENCLOSURE
5
WF-1AENCLOSURE
ATXH0508
TM
FINNED TUBE RADIATIONDIMENSIONS & CAPACITIES
NOTES: Capacities are based on 3 fps (0.9 m/s) water velocity. 3/4” x 4” x 4” (19mm x 102mm x 102mm) Cu/AL element has the same capacity as 1 1/4” x 4” x 4” (32mm x 102mm x 102mm) Cu/AL element for the same fl ow rate (GPM (L/s)). For capacity correction see page 81 and page 16 for type C bottom. Refer to fl ow chart on page 86 for pressure drop data.
3 3/8"
4 7/8"TO
12"
5"(127)
2 3/8"
7 5/8"
2"
(60)
(194)
(51)
(86)
(124)
(305)
6"
TO4 7/8"(124)
3 3/8"(86)
18"
(152)(457)
1" (25)
(127)5"
2"(51)
13 5/8"(346)
2 3/8"(60)
2 5/8"(67)
3 3/8"(86)TO
4 7/8"(124)
24"(610)
1" (25)
5"(127)
8"(203)
11 5/8"(295)
2 3/8"(60)
2"(51)
(67)2 5/8" 2 5/8"
(67)
1" (25)
6"(152)
OR
12"(305)
26502920 2350
24"
24"
24"
18"
18"
12"
610mm
610mm
457mm
610mm
457mm
305mm
ENCLOSUREHEIGHT
3.27 3.43 3.10 1.992.552.81 2.26
1 PSI AT 65°F AIR
CAPACITIES OF TYPE WF-1A ENCLOSURES
IMP
ER
IAL
ME
TRIC
ELEMENT
32mm
COPPER TUBE
102mm X 102mm
ALUMINUM FIN
164 FINS/M
STEAM CAP. / m6.89 kPa at 18°C
kW/m
2.68
2.87
ROWS
2.09
2.19
1.89
2.47
2.312.81
3.02
2.55
2.73 1.98
1.852.09
2.24
1.63
1.75
HOT WATER CAPACITY kW/m at 18°C AIRAVERAGE WATER TEMPERATURE °C
1.80
1.88
1.62
104
2.30
2.20
1.99
9399
1.99
2.08
1.80
82
1.44
1.51
1.31
88
1.63
1.71
1.48
77
1.28
1.34
1.15
AIR
2 (6" CENTERS)
2 (305mm CTRS)
2 (152mm CTRS)
2 (152mm CTRS)
1
1
1
ENCLOSUREHEIGHT
3400 32303570 2070
ELEMENT ROWSSTEAM CAP. / FT
BTU/HR/FT
HOT WATER CAPACITY BTU/HR/FT AT 65°F AIRAVERAGE WATER TEMPERATURE °F
1 1/4"
COPPER TUBE
4" X 4"
ALUMINUM FIN
50 FINS/FT
1
2 (12" CENTERS)
2 (6" CENTERS)
1
1
2990
2790
2280
2180
1970 2070
3140
2930
2390
2290
1870
2840
2070
2650
2170
1690
2570
1870
2400
1960
1540
2330
1700
2180
1780
1360
2060
1500
1930
1570
1200
1820
1330
1700
1390
220 210 200 190 180 170
6ATXH0508
TM
7"
14"
1" (25)
5"(127)
2 5/8"
2 3/8"
9 3/8"
2 1/4"
(60)
(238)
(57)
(67)
(178)
(356)
4 1/4"18"
(108)(457)
1" (25)
(127)5"
2 1/4"(57)
13 3/8"(340)
2 5/8"(67)
24"(610)
1" (25)
5"(127)
2 1/4"(57)
19 3/8"(492)
2 5/8"(67)
6 5/8"(168)TO
8 1/8"(206)
(267)10 1/2"
OR
(133)5 1/4"
(60)2 3/8"
6 5/8"
8 1/8"(206)
(168)TO
(60)2 3/8"
ELEMENT ROWSSTEAM CAP. / FT1 PSI AT 65°F AIR
BTU/HR/FT
HOT WATER CAPACITY BTU/HR/FT AT 65°F AIRAVERAGE WATER TEMPERATURE °F
1 1/4"COPPER TUBE
4" X 4"ALUMINUM FIN
50 FINS/FT
1
2 (10 1/2" CTRS)
2 (4 1/4" CTRS)
1
1
2510
2350
1910
1830
1710 1800
2640
2460
2010
1920
1627
2390
1740
2230
1820
1470
2160
1570
2020
1650
1343
1960
1430
1830
1490
1180
1730
1260
1620
1320
1047
1530
1120
1430
1170
220 210 200 190 180 170
CAPACITIES OF TYPE WF-1B ENCLOSURES
ELEMENT
32mmCOPPER TUBE
102mm X 102mmALUMINUM FIN
164 FINS/M
STEAM CAP. / m6.89 kPa at 18°C
kW/m
2.26
2.41
ROWS
1.76
1.84
1.64
2.08
1.942.37
2.54
2.14
2.30 1.66
1.561.76
1.88
1.38
1.47
HOT WATER CAPACITY kW/m at 18°C AIRAVERAGE WATER TEMPERATURE °C
1.51
1.59
1.41
104
1.93
1.85
1.73
9399
1.67
1.75
1.56
82
1.21
1.27
1.13
88
1.30
1.43
1.29
77
1.08
1.13
1.01
AIR
2 (5 1/4" CTRS)
2 (267mm CTRS)
2 (133mm CTRS)
2 (108mm CTRS)
1
1
1
ENCLOSUREHEIGHT
2850 27103000 174022302450 1970
24"
24"
24"
18"
18"
14"
610mm
610mm
457mm
610mm
457mm
356mm
ENCLOSUREHEIGHT
2.74 2.88 2.61 1.672.142.36 1.89
ME
TRIC
IMP
ER
IAL
NOTES: Capacities are based on 3 fps (0.9 m/s) water velocity. 3/4” x 4” x 4” (19mm x 102mm x 102mm) Cu/AL element has the same capacity as 1 1/4” x 4” x 4” (32mm x 102mm x 102mm) Cu/AL element for the same fl ow rate (GPM (L/s)). For capacity correction see page 81. Refer to fl ow chart on page 86 for pressure drop data.
WF-1BENCLOSURE
FINNED TUBE RADIATIONDIMENSIONS & CAPACITIES
7
WF SERIES
ATXH0508
TM
NYLONROLLER
BRACKETENCLOSURE
NTS
PILASTER KIT JOGGLE STRIPS
USE WITH:WF-1,2,3,5
1" (25mm) JOGGLE
FLAT JOGGLEUSE WITH:WF-4,6,7 & MS
ENCLOSUREBRACKET
USE WITH:WF-1,2,3,5,6
ELEMENTHANGER
USE WITH:WF-4,7
LAP OUTSIDE CORNER DAMPER
END CAPS
LEFTHAND
HANDRIGHT
INSIDE CORNER(FEMALE)
(MALE)
ACCESS DOORFIELD
RECESSEDKNOB OR
STYLES
THE FOLLOWING ACCESSORIES ARE AVAILABLE IN SEVERAL SIZES AND MOST STYLES OF ENCLOSURES
FINNED TUBE RADIATIONTYPICAL ACCESSORIES
TM
8
WF SERIES
ATXH0508
ENCLOSURE AND ACCESSORIES
Airtex enclosures are manufactured for quick and simple installation to minimize job-site labor. In order to provide the most rigid installation, support should be provided in the fi nished wall and should extend along the top edge of all enclosures to provide rigid support for the joggle strip.
INSTRUCTIONS FOR INSTALLATION
A chalk line should be drawn on the wall at the height of the enclosure (plus 4” (102mm) for Type A bottom).
1. Joggle Strip: fasten directly below the chalk line with screws or nails. 1” joggle strip is installed continuously with enclosure. Where laps or corners are to be installed, run joggle to within 1” (25mm) of the corner or adjacent wall. Joggle should be slightly loose to allow the lap or corner to fi t between joggle and wall. Where end caps are to be installed, joggle should be fl ush with the end of the enclosure.
2. Enclosure Bracket: butt the enclosure bracket up to the joggle strip and on 4’-0” (1219mm) centers (maximum). Fasten to the wall through the dimpled holes.
3. Element Hanger: mount element hanger on enclosure bracket at desired height.4. Element: set the element onto the hanger and connect the element to the system.5. Enclosure: hook the enclosure into the joggle strip. Press on face of the enclosure until the lower edge clips into
place.6. Butt Joints: after hooking the enclosure to the joggle strip, slide sideways to connect successive enclosure
lengths.7. Corners: hook top edge of inside and outside corners over joggle strip and bend tabs at bottom, securing the
corner to the enclosure.8. Laps: used where the enclosure is wall to wall. Hook the lap over the joggle strip and bend tabs at bottom
securing it to the enclosure.9. Field Mount Access Doors: cut 6 1/2” x 6 1/2” (165mm x 165mm) hole in cabinet front at required location (must
be 1 1/4” (32mm) from edge or break) and mount access door using sheet metal screws.10. End Caps: complete the enclosure installation by installing end caps where required.
5
9
10
5
55
7
7
95 8
1
6
1" (25mm) JOGGLE
BUTT JOINT
FINNED TUBE RADIATIONINSTALLATION INSTRUCTIONS
9
WF SERIES
ATXH0508
TM
FINNED TUBE RADIATIONINSTALLATION INSTRUCTIONS
2
1
3
1/4" (6mm)
WF-4 & WF-7 INSTALLATION OF BRACKETS AND JOGGLE
A chalk line should be drawn on the wall at the height of the enclosure (plus 4” (102mm) for Type A bottom).
1. Enclosure Bracket: fasten directly below the chalk line with screws or nails.2. Flat Joggle: fasten directly below the chalk line next to the enclosure bracket. Alternate joggle and
bracket insuring that there are at least two enclosure brackets per piece of enclosure and an enclosure bracket within 6” (152mm) of the end of a run of enclosure.
TYPE ‘C’ BOTTOM INSTALLATION
1. Fasten ‘C’ fl oor angle to fl oor. The fl oor angle is mounted at the enclosure depth from the wall (typically 5” (127mm) for standard enclosure). The fl oor angle is installed continuously with the enclosure. Where laps are to be installed, run the fl oor a e to within 1” (25mm) of the adjacent wall. Where corners are to be installed run the fl oor angle to within 1” (25mm) of the adjacent fl oor angle.
2. Hook the enclosure into the joggle strip at the top and attach the bottom of the enclosure to the fl oor angle as required.
3. Laps and corners are designed to be screwed to the fl oor angle at the bottom.
TM
10ATXH0508
3
1" (25mm) JOGGLE
5
5
64
3
1
2
3
1
2
9
10
8
7
6
BACK PANEL WITH INTEGRAL
ENCLOSURE AND ACCESSORIES
All enclosures are manufactured for quick and simple installations to minimize job-site labour.
FREE STANDING (WF-2A-FS) INSTALLATION INSTRUCTIONS
1. Pedestals: align the pedestals allowing 2 pedestals per piece of enclosure, and mount solidly to the fl oor. (keep 5” (127mm) clear of panel joints to avoid interference between vertical members of pedestal and male/female joiners).
2. Enclosure Bracket: adjust the height of the enclosure brackets so that they are level. The enclosure brackets are height adjustable on the pedestal to accommodate fl oor level variations.
3. Element Hanger: mount element hanger on vertical member of the enclosure bracket at desired height.4. Element: set the element onto the hanger and connect the element to the system.5. Back Panel: install the back panel. This panel has an integral 1” (25mm) joggle at the top, which fi ts over the
vertical member of the enclosure bracket. The bottom of the panel is retained by the spring clip. The back panel incorporates male/female joiners to align the butt joints. After placing the back panel on the enclosure bracket, slide sideways to connect successive back panel lengths.
6. Front Panel: hook the enclosure front panel into the joggle and press on face of the enclosure until the spring clip engages the bottom channel.
7. Butt Joints: after hooking the enclosure to the joggle strip, slide sideways to connect successive enclosure lengths.
8. Corners: corners are one piece and cover the back panel as well as the front panel. Gently spread the corner apart and place over the enclosure. Bend tabs at bottom in front and back securing it to the enclosure.
9. Laps: used where the enclosure is wall to wall. Laps are one piece and cover back panel as well as the front panel. Gently spread the lap apart and place over the enclosure. Bend tabs at bottom in front and in back securing it to the enclosure.
10. End Caps: complete the enclosure installation by installing end caps where required.
WF (FS) SERIES FINNED TUBE RADIATIONINSTALLATION INSTRUCTIONS
11
WF SERIES
ATXH0508
TM
EnclosureLength
Required
WF Series Enclosures
EnclosureBrackets
EnclosureLength
Required
WF Series Enclosures
EnclosureBrackets
EnclosureLength
Required
WF Series Enclosures
EnclosureBrackets
6' and under (1828mm) Varies 2 17' 6"
(5334mm)1 - 5' 6"
2 - 6' 6 29'(8839mm)
2 - 5' 6"3 - 6' 10
6' 6" (1981mm)
1 - 3'1 - 3' 6" 4 18'
(5486mm) 3 - 6' 6 29' 6" (8991mm)
1 - 5' 6" 4 - 6' 10
7'(2133mm) 2 - 3' 6" 4 18' 6"
(5638mm)3 - 4' 6"
1 - 5' 8 30'(9144mm) 5 - 6' 10
7' 6" (2286mm)
1 - 3' 6"1 - 4' 4 19'
(5791mm)2 - 4' 6" 2
- 5' 8 30' 6" (9296mm)
5 - 5' 5 -5' 6" 12
8'(2438mm) 2 - 4' 4 19' 6"
(5943mm)1 - 4' 6"
3 - 5' 8 31'(9448mm)
4 - 5'2 - 5' 6" 12
8' 6" (2590mm)
1 - 4' 1 - 4' 6" 4 20'
(6096mm) 4 - 5' 8 31' 6" (9601mm)
3 - 5'3 - 5' 6" 12
9'(2743mm) 2 - 4' 6" 4 20' 6"
(6248mm)3 - 5' 1
- 5' 6" 8 32'(9753mm)
2 - 5' 4 -5' 6" 12
9' 6" (2895mm)
1 - 4' 6"1 - 5' 4 21'
(6400mm)2 - 5' 2 -
5' 6" 8 32' 6" (9906mm)
1 - 5'5 - 5' 6" 12
10'(3048mm) 2 - 5' 4 21' 6"
(6553mm)1 - 5' 3
- 5' 6" 8 33'(10058mm) 6 - 5' 6" 12
10' 6" (3200mm)
1 - 5' 1 - 5' 6" 4 22'
(6705mm) 4 - 5' 6" 8 33' 6" (10210mm)
5 - 5' 6"1 - 6' 12
11'(3352mm) 2 - 5' 6" 4 22' 6"
(6858mm)3 - 5' 6"
1 - 6' 8 34'(10363mm)
4 - 5' 6"2 - 6' 12
11' 6" (3505mm)
1 - 5' 6"1 - 6' 4 23'
(7010mm)2 - 5' 6"
2 - 6' 8 34' 6" (10515mm)
3 - 5' 6"3 - 6' 12
12'(3657mm) 2 - 6' 4 23' 6"
(7162mm)1 - 5' 6"
3 - 6' 8 35'(10668mm)
2 - 5' 6"4 - 6' 12
12' 6" (3810mm)
2 - 4' 1 -4' 6" 6 24'
(7315mm) 4 - 6' 8 35' 6" (10820mm)
1 - 5' 6"5 - 6' 12
13'(3962mm)
1 - 4' 2 -4' 6" 6 24' 6"
(7467mm)1 - 4' 6"
4 - 5' 10 36'(10970mm) 6 - 6' 12
13' 6" (4114mm) 3 - 4' 6" 6 25'
(7620mm) 5 - 5' 10 36' 6" (11125mm)
4 - 5' 3 - 5' 6" 14
14'(4267mm)
2 - 4' 6"1 - 5' 6 25' 6"
(7772mm)4 - 5' 1 -
5' 6" 10 37'(11277mm)
3 - 5' 4 - 5' 6" 14
14' 6" (4419mm)
1 - 4' 6" 2 - 5' 6 26'
(7924mm)3 - 5'
2 - 5' 6" 10 37' 6" (11430mm)
2 - 5'5 - 5' 6" 14
15'(4572mm) 3 - 5' 6 26' 6"
(8077mm)2 - 5'
3 - 5' 6" 10 38'(11582mm)
1 - 5'6 - 5' 6" 14
15' 6" (4724mm)
2 - 5' 1 - 5' 6" 6 27'
(8229mm)1 - 5' 4 -
5' 6" 10 38' 6" (11734mm) 7 - 5' 6" 14
16'(4876mm)
1 - 5'2 - 5' 6" 6 27' 6"
(8382mm) 5 - 5' 6" 10 39'(11887mm)
6 - 5' 6"1 - 6' 14
16' 6" (5029mm) 3 - 5' 6" 6 28'
(8534mm)4 - 5' 6"
1 - 6' 10 39' 6" (12039mm)
5 - 5' 6"2 - 6' 14
17'(5181mm)
2 - 5' 6"1 - 6' 6 28' 6"
(8686mm)3 - 5' 6"
2 - 6' 10 40'(12192mm)
4 - 5' 6"3 - 6' 14
WF-2A-FS requires 2 pedestals per enclosure piece minimum. This guide is intended for standard applications only.
ENCLOSURE AND BRACKET SELECTION GUIDE
FINNED TUBE RADIATION
TM
12
WF SERIES
ATXH0508
TYPE BTU / HR / FTON PLAN (kW)
FINNED TUBE RADIATION SCHEDULE(BASED ON AIRTEX HYDRONIC SYSTEMS)
MODEL REMARKS
FINNED TUBE RADIATIONSPECIFICATION
FINNED TUBE RADIATION
1. Copper-aluminum element shall be _____ 1 1/4” (32mm) _____ 3/4” (19mm) nominal I.D. seamless copper with 4”x4” (102x102mm) aluminum fi n. Fins to be stamped for rigidity and have integral collars to provide even spacing of 50 fi ns/foot (164 fi ns/m) and maximum heat transfer. Tube ends suitable for sweat connecting. Heavy gauge element hangers shall be provided for mounting on the enclosure bracket and shall consist of rigid galvanized steel with peg board style mounting hook and nylon roller bearing to allow for free expansion. Element hanger shall swing from mounting hole for free expansion of element. Centre on minimum 4 ft. (1.2m).
2. Enclosure cabinets shall be constructed of 18 gauge (1.2mm) (16 gauge (1.5mm) for cabinets over 18” (457mm) high) _____16 gauge (1.5mm) _____ 14 gauge (1.9mm) satin coat steel with electrostatically applied powder coat prime fi nish. Unless otherwise indicated, cabinets will be supported at the top by a 1” (25mm) joggle strip mounted to the wall and at the bottom by support brackets on not more than 4 ft. (1.2m) centres. Enclosures to have factory gusset plates to maintain shape during shipment and installation. Enclosure cabinets shall have pencil proof louvres. Enclosure cabinets shall have self-aligning butt joint connections of a male end and a female end to insure a smooth joint between adjacent enclosure pieces.
3. Enclosure cabinet sizes and styles shall be Airtex Hydronic Systems as indicated on drawings and/or schedules.
13 ATXH0508
TM
3 3/8"
4 7/8"TO
12"
1" (25)
5"(127)
2 5/8"
2 3/8"
7 5/8"
2"
(60)
(194)
(51)
(67)
(86)
(124)
(305)
6"
TO4 7/8"(124)
3 3/8"(86)
18"
(152)
(457)
1" (25)
(127)5"
2"(51)
13 5/8"(346)
2 3/8"(60)
2 5/8"(67)
3 3/8"(86)TO
4 7/8"(124)
24"(610)
1" (25)
5"(127)
8"(203)
11 5/8"(295)
2 3/8"(60)
2"(51)
(67)2 5/8"
6"(152)
(305)12"
OR
ELEMENT ROWSSTEAM CAP. / FT
BTU/HR/FT
HOT WATER CAPACITY BTU/HR/FT AT 65°F AIRAVERAGE WATER TEMPERATURE °F
1 1/4"
COPPER TUBE
4" X 4"
ALUMINUM FIN
50 FINS/FT
1
2 (12" CENTERS)
2 (6" CENTERS)
1
1
3070
2810
2470
2300
2060 2160
3220
2950
2590
2420
1960
2920
2190
2670
2350
1770
2640
1980
2420
2120
1610
2390
1790
2190
1930
1420
2120
1590
1940
1700
1260
1870
1400
1710
1510
220 210 200 190 180 170
CAPACITIES OF TYPE WF-2A ENCLOSURES
ELEMENT
32mm
COPPER TUBE
102mm X 102mm
ALUMINUM FIN
164 FINS/M
STEAM CAP. / m6.89 kPa at 18°C
kW/m
2.70
2.95
ROWS
2.21
2.37
1.98
2.54
2.332.84
3.10
2.57
2.81 2.04
1.862.11
2.30
1.64
1.80
HOT WATER CAPACITY kW/m at 18°C AIRAVERAGE WATER TEMPERATURE °C
1.90
2.04
1.70
104
2.49
2.33
2.08
9399
2.11
2.26
1.88
82
1.53
1.63
1.37
88
1.72
1.86
1.55
77
1.35
1.45
1.21
AIR
2 (6" CENTERS)
2 (305mm CTRS)
2 (152mm CTRS)
2 (152mm CTRS)
1
1
1
ENCLOSUREHEIGHT
3510 33303690 214027403020 2420
24"
24"
24"
18"
18"
12"
610mm
610mm
457mm
610mm
457mm
305mm
ENCLOSUREHEIGHT
3.37 3.55 3.20 2.062.632.90 2.33
1 PSI AT 65°F AIR
IMP
ER
IAL
ME
TRIC
WF-2AENCLOSURE
FINNED TUBE RADIATIONDIMENSIONS & CAPACITIES
NOTES: Capacities are based on 3 fps (0.9 m/s) water velocity. 3/4” x 4” x 4” (19mm x 102mm x 102mm) Cu/AL element has the same capacity as 1 1/4” x 4” x 4” (32mm x 102mm x 102mm) Cu/AL element for the same fl ow rate (GPM (L/s)). For capacity correction see page 81 and page16 for type B or C bottom. Refer to fl ow chart on page 86 for pressure drop data.
14ATXH0508
TM
1" (25)
3 1/4"(83)
4 1/2"(114)
3 1/2"(89)TO
4 1/2"(114)
4" (102)
(114)
(114)
(89)
4 1/2"TO
4" (102)
3 1/2"
(83)3 1/4"
1" (25)4 1/2"
8"(203)
4 3/8"(111)
12"(305)
(89)
4 1/2"(114)
TO
4" (102)
2 3/8"3 1/2"
3 1/4"
1" (25)
(83)
4 1/2"(114)
12"(305)
4 3/8"(111)TO6"
(152)
16"(406)
(152)
(111)4 3/8"
6"TO
6"(152)
20"(508)
16"(406)
(60)Ø STAND
2 3/8"(60)
Ø STAND
2 3/8"(60)
Ø STAND
ELEMENT ROWSSTEAM CAP. / FT
BTU/HR/FT
HOT WATER CAPACITY BTU/HR/FT AT 65°F AIRAVERAGE WATER TEMPERATURE °F
1 1/4"COPPER TUBE
4" X 4"ALUMINUM FIN
50 FINS/FT
1
2 (6" CENTERS)
1
1
2725
2235
2060
1890 1985
2860
2345
2160
1795
1960
2590
2120
1625
1770
2345
1920
1475
1605
2125
1740
1305
1420
1880
1540
1150
1255
1660
1360
220 210 200 190 180 170
CAPACITIES OF TYPE WF-2A-FS ENCLOSURES
ELEMENT
32mmCOPPER TUBE
102mm X 102mmALUMINUM FIN
164 FINS/M
STEAM CAP. / m6.89 kPa at 18°C
kW/m
2.62
ROWS
1.98
2.15
1.82
2.252.75 2.49 1.812.04 1.60
HOT WATER CAPACITY kW/m at 18°C AIRAVERAGE WATER TEMPERATURE °C
1.70
1.85
1.56
104
2.25
2.08
1.91
9399
1.88
2.04
1.73
82
1.37
1.48
1.25
88
1.54
1.67
1.42
77
1.21
1.31
1.11
AIR
2 (152mm CTRS)
1
1
1
ENCLOSUREHEIGHT
16"
12"
16"
8"
305mm
406mm
406mm
203mm
ENCLOSUREHEIGHT
1 PSI AT 65°F AIR
ME
TRIC
IMP
ER
IAL
NOTES: Capacities are based on 3 fps (0.9 m/s) water velocity. 3/4” x 4” x 4” (19mm x 102mm x 102mm) Cu/AL element has the same capacity as 1 1/4” x 4” x 4” (32mm x 102mm x 102mm) Cu/AL element for the same fl ow rate (GPM (L/s)). For capacity correction see page 81. Refer to fl ow chart on page 86 for pressure drop data.
WF-2A-FSENCLOSURE
WITH ADJUSTABLE PEDESTAL
FINNED TUBE RADIATIONDIMENSIONS & CAPACITIES
15 ATXH0508
TM
NOTES: Capacities are based on 3 fps (0.9 m/s) water velocity. 3/4” x 4” x 4” (19mm x 102mm x 102mm) Cu/AL element has the same capacity as 1 1/4” x 4” x 4” (32mm x 102mm x 102mm) Cu/AL element for the same fl ow rate (GPM (L/s)). For capacity correction see page 81 and page16 for type B or C bottom. Refer to fl ow chart on page 86 for pressure drop data.
FINNED TUBE RADIATIONDIMENSIONS & CAPACITIESWF-3A
ENCLOSURE
3 3/8"
4 7/8"TO
12"
1" (25)
5"(127)
2 5/8"
2 3/8"
7 5/8"
2"
(60)
(194)
(51)
(67)
(86)
(124)
(305)
6"
TO4 7/8"(124)
3 3/8"(86)
18"
(152)(457)
1" (25)
(127)5"
2"(51)
13 5/8"(346)
2 3/8"(60)
2 5/8"(67)
3 3/8"(86)TO
4 7/8"(124)
24"(610)
1" (25)
5"(127)
8"(203)
11 5/8"(295)
2 3/8"(60)
2"(51)
(67)2 5/8"
(152)
OR6"
(305)12"
STEAM CAP. / m6.89 kPa at 18°C
kW/m
2.61
2.82
ROWS
2.05
2.18
1.85
2.42
2.252.75
2.96
2.48
2.67 1.94
1.812.04
2.20
1.60
1.72
HOT WATER CAPACITY kW/m at 18°C AIRAVERAGE WATER TEMPERATURE °C
1.76
1.87
1.59
104
2.29
2.15
1.94
9399
1.94
2.08
1.75
82
1.41
1.51
1.27
88
1.60
1.70
1.44
77
1.25
1.33
1.12
AIR
2 (6" CENTERS)
2 (305mm CTRS)
2 (152mm CTRS)
2 (152mm CTRS)
1
1
1
ENCLOSUREHEIGHT
3330 31603500 203026002860 2300
24"
24"
24"
18"
18"
12"
610mm
610mm
457mm
610mm
457mm
305mm
ENCLOSUREHEIGHT
3.20 3.36 3.04 1.952.502.75 2.21
1 PSI AT 65°F AIR
IMP
ER
IAL
ME
TRIC
ELEMENT
32mmCOPPER TUBE
102mm X 102mm
ALUMINUM FIN164 FINS/M
ELEMENT ROWSSTEAM CAP. / FT
BTU/HR/FT
HOT WATER CAPACITY BTU/HR/FT AT 65°F AIRAVERAGE WATER TEMPERATURE °F
1 1/4"COPPER TUBE
4" X 4"ALUMINUM FIN
50 FINS/FT
1
2 (12" CENTERS)
2 (6" CENTERS)
1
1
2930
2720
2270
2130
1920 2020
3080
2860
2380
2240
1820
2780
2020
2580
2160
1650
2520
1830
2340
1950
1500
2290
1660
2120
1770
1320
2020
1470
1880
1570
1170
1790
1300
1660
1380
220 210 200 190 180 170
CAPACITIES OF TYPE WF-3A ENCLOSURES
16ATXH0508
TM
6"(152)
(92)3 5/8"
5 1/4"(133)
3/4" (19)
1 7/8"(48)
1 1/8"(29)
3"(76)
(67)2 5/8"
REMOVALCLEARANCE
3 5/8"(92)
6"(152)
12"(305)
CLEARANCEREMOVAL
3/4" (19)
5 1/4"(133)
2 5/8"(67)
2 1/8"(54)
5 1/2"(140)
4 3/8"(111)3 5/8"
(92)
12"(305)
18"(457)
CLEARANCEREMOVAL
3/4" (19)
5 1/4"(133)
2 5/8"(67)
2 1/8"(54)
6"(152)
5 1/2"(140)
4 3/8"(111)
OR
(152)6"
ELEMENT
32mmCOPPER TUBE
102mm X 102mmALUMINUM FIN
164 FINS/M
STEAM CAP. / m6.89 kPa at 18°C
kW/m
2.98
3.79
ROWS
2.37
2.90
1.51
3.26
2.573.13
3.98
2.84
3.60 2.61
2.062.33
2.95
1.82
2.31
HOT WATER CAPACITY kW/m at 18°C AIRAVERAGE WATER TEMPERATURE °C
2.04
2.50
1.30
104
3.05
2.49
1.59
9399
2.26
2.76
1.43
82
1.63
2.00
1.04
88
1.86
2.27
1.17
77
1.45
1.77
0.92
AIR
3 (6" CENTERS)
3 (305mm CTRS)
3 (152mm CTRS)
1
ENCLOSUREHEIGHT
30"
18"
12"
18"
6"
762mm
305mm
457mm
457mm
152mm
ENCLOSUREHEIGHT
2 (12" CENTERS)
2 (152mm CTRS)
2 (305mm CTRS)
1 PSI AT 65°F AIR
ME
TRIC
IMP
ER
IAL
ELEMENT ROWSSTEAM CAP. / FT
BTU/HR/FT
HOT WATER CAPACITY BTU/HR/FT AT 65°F AIRAVERAGE WATER TEMPERATURE °F
1 1/4"COPPER TUBE
4" X 4"ALUMINUM FIN
50 FINS/FT
1
3 (12" CENTERS)
2 (6" CENTERS)
3940
3100
3020
2470
1570 1650
4140
3260
3170
2590
1490
3740
2350
2950
2870
1350
3390
2120
2670
2600
1220
3070
1930
2420
2360
1080
2720
1700
2140
2080
960
2400
1510
1890
1840
220 210 200 190 180 170
CAPACITIES OF TYPE WF-4A ENCLOSURES
NOTES: Capacities are based on 3 fps (0.9 m/s) water velocity. 3/4” x 4” x 4” (19mm x 102mm x 102mm) Cu/AL element has the same capacity as 1 1/4” x 4” x 4” (32mm x 102mm x 102mm) Cu/AL element for the same fl ow rate (GPM (L/s)). For capacity correction see page 81. Refer to fl ow chart on page 86 for pressure drop data. Flat joggle recommended between brackets.
WF-4AENCLOSURE
FINNED TUBE RADIATIONDIMENSIONS & CAPACITIES
17 ATXH0508
TM
6 3/4"
12"
5"(127)
2"
7 5/8"
2 7/16"
(51)
(194)
(62)
(171)
(305)
5" 18"(127) (457)
2 7/16"(62)
13 5/8"(346)
2"(51)
24"(610)
8"(203)
11 5/8"(295)
2"(51)
2 7/16"(62)
(67)2 5/8"
1" (25)
(67)2 5/8"
1" (25) 1" (25)
2 5/8"(67)
5"(127)
(127)5"
(254)
(127)
10"
5"OR
8 1/4"(210)TO
6 3/4"(171)
6 3/4"(171)
(210)8 1/4"
TO
ELEMENT ROWSSTEAM CAP. / FT
BTU/HR/FT
HOT WATER CAPACITY BTU/HR/FT AT 65°F AIRAVERAGE WATER TEMPERATURE °F
1 1/4"COPPER TUBE
4" X 4"ALUMINUM FIN
50 FINS/FT
1
2 (10" CENTERS)
2 (5" CENTERS)
1
1
2601
2427
1984
1897
1714 1801
2732
2549
2079
1992
1627
2471
1801
2306
1888
1470
2236
1627
2088
1705
1340
2027
1479
1897
1549
1183
1792
1305
1679
1366
1044
1583
1157
1479
1209
220 210 200 190 180 170
CAPACITIES OF TYPE WF-5A ENCLOSURES
ELEMENT
32mmCOPPER TUBE
102mm X 102mmALUMINUM FIN164 FINS/M
STEAM CAP. / m6.89 kPa at 18°C
kW/m
2.33
2.50
ROWS
1.82
1.91
1.65
2.15
2.012.45
2.63
2.22
2.38 1.72
1.611.82
1.95
1.42
1.52
HOT WATER CAPACITY kW/m at 18°C AIRAVERAGE WATER TEMPERATURE °C
1.56
1.64
1.41
104
2.00
1.91
1.73
9399
1.73
1.82
1.56
82
1.25
1.31
1.14
88
1.42
1.49
1.29
77
1.11
1.16
1.00
AIR
2 (5" CENTERS)
2 (254mm CTRS)
2 (127mm CTRS)
2 (127mm CTRS)
1
1
1
ENCLOSUREHEIGHT
2958 28103106 180123062540 2045
24"
24"
24"
18"
18"
12"
610mm
610mm
457mm
610mm
457mm
305mm
ENCLOSUREHEIGHT
2.84 2.99 2.70 1.732.222.44 1.97
1 PSI AT 65°F AIR
ME
TRIC
IMP
ER
IAL
NOTES: Capacities are based on 3 fps (0.9 m/s) water velocity. 3/4” x 4” x 4” (19mm x 102mm x 102mm) Cu/AL element has the same capacity as 1 1/4” x 4” x 4” (32mm x 102mm x 102mm) Cu/AL element for the same fl ow rate (GPM (L/s)). Capacity is derated for mounting higher than 36” above the fl oor. For capacity correction see page 81. Refer to fl ow chart on page 86 for pressure drop data.
WF-5A INVERTED ENCLOSURE
FINNED TUBE RADIATIONDIMENSIONS & CAPACITIES
18ATXH0508
TM
24"(610)
5"(127)
8"(203)
11 5/8"(295)
2 3/8"(60)
2"(51)
(67)2 5/8"
3/4" (19)
3/4"(19)
3/4" (19)
3/4"(19)
3/4" (19)
(19)3/4"
12"(305)OR
(152)6"
3 1/2"(89)
3 1/2"(89)
3 1/2"(89)
3 3/8"
4 7/8"TO
12"
5"(127)
2 5/8"
2 3/8"
7 5/8"
2"
(60)
(194)
(51)
(67)
(86)
(124)
(305)
6"
TO4 7/8"(124)
3 3/8"(86)
18"
(152)(457)
(127)5"
2"(51)
13 5/8"(346)
2 3/8"(60)
2 5/8"(67)
3 3/8"(86)TO
4 7/8"(124)
ELEMENT ROWSSTEAM CAP. / FT
BTU/HR/FT
HOT WATER CAPACITY BTU/HR/FT AT 65°F AIRAVERAGE WATER TEMPERATURE °F
1 1/4"
COPPER TUBE
4" X 4"
ALUMINUM FIN
50 FINS/FT
1
2 (12" CENTERS)
2 (6" CENTERS)
1
1
3070
2810
2470
2300
2060 2160
3220
2950
2590
2420
1960
2920
2190
2670
2350
1770
2640
1980
2420
2120
1610
2390
1790
2190
1930
1420
2120
1590
1940
1700
1260
1870
1400
1710
1510
220 210 200 190 180 170
CAPACITIES OF TYPE WF-6A ENCLOSURES
MET
RIC
IMP
ER
IAL
ELEMENT
32mm
COPPER TUBE
102mm X 102mm
ALUMINUM FIN
164 FINS/M
STEAM CAP. / m6.89 kPa at 18°C
kW/m
2.70
2.95
ROWS
2.21
2.37
1.98
2.54
2.332.84
3.10
2.57
2.81 2.04
1.862.11
2.30
1.64
1.80
HOT WATER CAPACITY kW/m at 18°C AIRAVERAGE WATER TEMPERATURE °C
1.90
2.04
1.70
104
2.49
2.33
2.08
9399
2.11
2.26
1.88
82
1.53
1.63
1.37
88
1.72
1.86
1.55
77
1.35
1.45
1.21
AIR
2 (6" CENTERS)
2 (305mm CTRS)
2 (152mm CTRS)
2 (152mm CTRS)
1
1
1
ENCLOSUREHEIGHT
3510 33303690 214027403020 2420
24"
24"
24"
18"
18"
12"
610mm
610mm
457mm
610mm
457mm
305mm
ENCLOSUREHEIGHT
3.37 3.55 3.20 2.062.632.90 2.33
1 PSI AT 65°F AIR
NOTES: Capacities are based on 3 fps (0.9 m/s) water velocity. 3/4” x 4” x 4” (19mm x 102mm x 102mm) Cu/AL element has the same capacity as 1 1/4” x 4” x 4” (32mm x 102mm x 102mm) Cu/AL element for the same fl ow rate (GPM (L/s)). For capacity correction see page 81. Refer to fl ow chart on page 86 for pressure drop data and page 16 for type B or C bottom. Continuous fl at joggle required. See page 90 for additional bar grille information.
WF-6AENCLOSURE WITH BAR GRILLE
FINNED TUBE RADIATIONDIMENSIONS & CAPACITIES
19 ATXH0508
TM
(54)
6"(152)
5 1/2"(140)
4 3/8"(111)
OR
(152)6"
6"(152)
(92)3 5/8"
5 1/4"(133)
3/4" (19)
1 7/8"(48)
1 1/8"(29)
3"(76)
(67)2 5/8"
REMOVALCLEARANCE
3 5/8"(92)
6"(152)
12"(305)
CLEARANCEREMOVAL
3/4" (19)
5 1/4"(133)
2 5/8"(67)
2 1/8"(54)
5 1/2"(140)
4 3/8"(111)3 5/8"
(92)
12"(305)
18"(457)
CLEARANCEREMOVAL
3/4" (19)
5 1/4"(133)
2 5/8"(67)
2 1/8"
ELEMENT ROWSSTEAM CAP. / FT
BTU/HR/FT
HOT WATER CAPACITY BTU/HR/FT AT 65°F AIRAVERAGE WATER TEMPERATURE °F
1 1/4"COPPER TUBE
4" X 4"ALUMINUM FIN
50 FINS/FT
1
2 (6" CENTERS)
3764
3443
2822
1688 1775
3948
3618
2968
1600
2677
3579
3269
1455
2425
3240
2959
1319
2202
2939
2687
1164
1950
2600
2377
1028
1727
2299
2105
220 210 200 190 180 170
CAPACITIES OF TYPE WF-7A ENCLOSURES
ELEMENT
32mmCOPPER TUBE
102mm X 102mmALUMINUM FIN
164 FINS/M
STEAM CAP. / m6.89 kPa at 18°C
kW/m
3.62
ROWS
2.71
3.31
1.62
3.123.80 3.44 2.502.83 2.21
HOT WATER CAPACITY kW/m at 18°C AIRAVERAGE WATER TEMPERATURE °C
2.33
2.85
1.40
104
3.48
2.85
1.71
9399
2.57
3.14
1.54
82
1.88
2.29
1.12
88
2.12
2.58
1.27
77
1.66
2.02
0.99
AIR
3 (6" CENTERS)
3 (152mm CTRS)
1
ENCLOSUREHEIGHT
18"
12"
18"
6"
305mm
457mm
457mm
152mm
ENCLOSUREHEIGHT
2 (12" CENTERS)
2 (152mm CTRS)
2 (305mm CTRS)
1 PSI AT 65°F AIR
ME
TRIC
IMP
ER
IAL
NOTES: Capacities are based on 3 fps (0.9 m/s) water velocity. 3/4” x 4” x 4” (19mm x 102mm x 102mm) Cu/AL element has the same capacity as 1 1/4” x 4” x 4” (32mm x 102mm x 102mm) Cu/AL element for the same fl ow rate (GPM (L/s)). For capacity correction see page 81. Refer to fl ow chart on page 86 for pressure drop data. Flat joggle recommended between brackets.
WF-7AEXPANDED METAL ENCLOSURE
FINNED TUBE RADIATIONDIMENSIONS & CAPACITIES
20ATXH0508
TM
5"
5"
5"
2 5/8" 2 5/8" 2 5/8"
12"
(152)
24"
3 3/8"
4 7/8" 4 7/8"
3 3/8"(86)TO
(124)
18"6"
12"
(124)
TO(86)3 3/8"
4 7/8"
(305)OR
6"
(127)
(127)
(127)
(305)
(457)
(152)
(610)
(124)
TO(86)
(67)(67)(67)
610mm
457mm
305mm
1
1
1
2 (12" CENTERS)
2 ( 6" CENTERS)
2 ( 6" CENTERS)
1
1
1
2 (152mm CTRS)
2 (305mm CTRS)
2 (152mm CTRS)
IMP
ER
IAL
ME
TRIC
CAPACITIES OF TYPE MS-2A ENCLOSURES
ELEMENT
ELEMENT
ROWS
ROWS
ENCLOSURE
ENCLOSURE
HEIGHT
HEIGHT
STEAM CAP. / FT HOT WATER CAPACITY BTU/HR/FT AT 65°F AIRAVERAGE WATER TEMPERATURE °F1 PSI AT 65°F AIR
BTU/HR/FT
kW/m
STEAM CAP. / m6.89 kPa AT 18°F
AIRHOT WATER CAPACITY kW/m AT 18°C AIR
AVERAGE WATER TEMPERATURE °C
32mmCOPPER TUBE
ALUMINUM FIN102mm X 102mm
164 FINS/M
50 FINS/FT
4" X 4"ALUMINUM FIN
COPPER TUBE1 1/4"
220 210 200 190 180 170
104 99 93 88 82 77
2160 1960 1770 1610 1420 12602060
2300 2420 2190 1980 1790 1590 1400
2470 2590 2350 2120 1930 1700 1510
3510
3070
2810
3690
3220
2950
3330
2920
2670
3020
2640
2420
2740
2390
2190
21402420
18702120
17101940
1.98 2.08 1.88 1.70 1.55 1.37 1.21
2.21 2.33 2.11 1.90 1.72 1.53 1.35
2.37
2.70 1.641.862.112.332.572.84
1.451.631.862.042.262.49
3.10 2.81 2.54 2.30 2.04 1.80
3.55 3.20 2.90 2.63 2.33 2.063.37
2.95
18"
24"
24"
24"
18"
12"
610mm
610mm
457mm
NOTES: Capacities are based on 3 fps (0.9 m/s) water velocity. 3/4” x 4” x 4” (19mm x 102mm x 102mm) Cu/AL element has the same capacity as 1 1/4” x 4” x 4” (32mm x 102mm x 102mm) Cu/AL element for the same fl ow rate (GPM (L/s)). For capacity correction see page 81. Refer to fl ow chart on page 86 for pressure drop data. Flat joggle required.
WF SERIES (MS-2A) MULLION ENCLOSURE
FINNED TUBE RADIATIONDIMENSIONS & CAPACITIES
21 ATXH0508
TM
(86)TO
(124)
(86)TO
(124)
(86)TO
(124)
(610)
(152)
(457)
(305)
(127)
(127)
(127)
(152)
OR(305)12” 24”
6”
3 3/8”
4 7/8”
18”
6”
4 7/8”
3 3/8”
12”
3 3/8”
4 7/8”
2 5/8"2 5/8"2 5/8"
5"
5"
5"
(67) (67) (67)
NOTES: Capacities are based on 3 fps (0.9 m/s) water velocity. 3/4” x 4” x 4” (19mm x 102mm x 102mm) Cu/AL element has the same capacity as 1 1/4” x 4” x 4” (32mm x 102mm x 102mm) Cu/AL element for the same fl ow rate (GPM (L/s)). For capacity correction see page 81. Refer to fl ow chart on page 86 for pressure drop data. Flat joggle required.
WF SERIES (MS-8A) MULLION ENCLOSURE
FINNED TUBE RADIATIONDIMENSIONS & CAPACITIES
CAPACITIES OF TYPE MS-2A ENCLOSURES
ME
TRIC
IMP
ER
IAL
2 (152mm CTRS)
2 (305mm CTRS)
2 (152mm CTRS)
1
1
1
2 ( 6" CENTERS)
2 ( 6" CENTERS)
2 (12" CENTERS)
1
1
1
305mm
457mm
610mm
457mm
610mm
610mm
12"
18"
24"
24"
24"
18"
2.95
3.37 2.062.332.632.903.203.55
1.802.042.302.542.813.10
2.49 2.26 2.04 1.86 1.63 1.45
2.84 2.57 2.33 2.11 1.86 1.642.70
2.37
1.351.531.721.902.112.332.21
1.211.371.551.701.882.081.98
1940 1710
2120 1870
2420 2140
2190
2390
2740
2420
2640
3020
2670
2920
3330
2950
3220
3690
2810
3070
3510
1510170019302120235025902470
1400159017901980219024202300
2060 126014201610177019602160
7782889399104
170180190200210220
1 1/4"
COPPER TUBE
ALUMINUM FIN
4" X 4"
50 FINS/FT
164 FINS/M
102mm X 102mm
ALUMINUM FIN
COPPER TUBE
32mm
AVERAGE WATER TEMPERATURE °CHOT WATER CAPACITY kW/m AT 18°C AIR
AIR6.89 kPa AT 18°FSTEAM CAP. / m
kW/m
BTU / HR / FT
1 PSI AT 65°F AIR AVERAGE WATER TEMPERATURE °FHOT WATER CAPACITY BTU/HR/FT AT 65°F AIRSTEAM CAP./FT
HEIGHT
HEIGHT
ENCLOSURE
ENCLOSURE
ROWS
ROWS
ELEMENT
ELEMENT
TM
22
WF SERIES
ATXH0508
TYPE A
STANDARD ENCLOSURE HAS AN OPEN BOTTOM ANDCAN BE INSTALLED DOWN TO WITHIN 4" (102mm)OF THE FLOOR.
TYPE B
16% LESS THAN WITH TYPE A ENCLOSURE BOTTOM.
ENCLOSURE IS USED AT INSTALLED HEIGHTSGREATER THAN 36" (914mm) ABOVE THE FLOOR.TYPE B BOTTOM MAY BE OBTAINED WITH SLOPETOP (WF-1B), FLAT TOP AND FRONT OUTLETGRILLE IN HEIGHTS OF 12" (305mm),
CAPACITY:m
28% LESS THAN WITH TYPE A ENCLOSURE BOTTOM.
ENCLOSURE IS USED WHEN ENCLOSURES MUSTSIT ON THE FLOOR. TYPE C BOTTOM INCLUDINGFLOOR ANGLE MAY BE OBTAINED WITH SLOPE TOP,FLAT TOP AND FRONT OUTLET GRILLE IN HEIGHTSOF 12" (305mm), 18" (457mm), AND 24" (610mm).
CAPACITY:
TYPE C
14" (356mm), 18" (457mm), AND 24" (610mm).
7 1/2"
9"TO
2 5/8"
2 1/4"(57)
(67)
(191)
(229)
3 3/8"
4 7/8"TO
2 5/8"
2"(51)
(67)
(86)
(124)
1/4"(6)
4 15/16"(125)
3 3/8"
4 7/8"TO
2"(51)
(86)
(124)
2 5/8"(67)
NOTE: Additional custom designed enclosures in a variety of styles and sizes may be obtained upon request.
FINNED TUBE RADIATIONENCLOSURE MODELS