Medium Voltage Electric Cable 3.3kv to 33kv
Medium Voltage Electric Cable 3.3kv to 33kv
(Integrated Management System (IMS) Certified Company)
A VIEW OF STATE OF ARTPLANT AND OUR MANUFACTURING PROCESS & FACILITIES
Contents Introduction ........................................................................................................................................................................1
Medium Voltage Cables Design and Construction to IEC 60502-2.................................................................................. 2-5 Electrical Parameters of the Cables to IEC 60502-2.............................................................................................. 6-7CURRENT RATINGS ......................................................................................................................................................... 8-13Single Core Cable - CU/XLPE/PVC, 3.6/6KV to IEC 60502-2............................................................................................ 14
Three Core Cable - CU/XLPE/PVC, 3.6/6KV ..................................................................................................................... 15
Three Core Cable - CU/XLPE/STA/PVC, 3.6/6KV............................................................................................................... 16
Three Core Cable - CU/XLPE/SWA/PVC, 3.6/6KV ............................................................................................................ 17
Single Core Cable - CU/XLPE/PVC, 6/10KV .................................................................................................................... 18
Three Core Cable - CU/XLPE/PVC, 6/10KV ...................................................................................................................... 19
Three Core Cable - CU/XLPE/STA/PVC, 6/10KV ............................................................................................................. 20
Three Core Cable - CU/XLPE/SWA/PVC, 6/10KV ............................................................................................................. 21
Single Core Cable - CU/XLPE/PVC, 8.7/15KV ...................................................................................................................22
Three Core Cable - CU/XLPE/PVC, 8.7/15KV ................................................................................................................... 23
Three Core Cable - CU/XLPE/STA/PVC, 8.7/15KV ............................................................................................................ 24
Three Core Cable - CU/XLPE/SWA/PVC, 8.7/15KV .......................................................................................................... 25
Single Core Cable - CU/XLPE/PVC, 12/20KV ................................................................................................................... 26
Three Core Cable - CU/XLPE/PVC, 12/20KV ................................................................................................................... 27
Three Core Cable - CU/XLPE/STA/PVC, 12/20KV ........................................................................................................... 28
Three Core Cable - CU/XLPE/SWA/PVC, 12/20KV ........................................................................................................... 29
Single Core Cable - CU/XLPE/PVC, 18/30KV ................................................................................................................... 30
Three Core Cable - CU/XLPE/PVC, 18/30KV ................................................................................................................... 31
Three Core Cable - CU/XLPE/STA/PVC, 18/30KV ........................................................................................................... 32
Three Core Cable - CU/XLPE/SWA/PVC, 18/30KV ........................................................................................................... 33
General Characteristics of Cables to SANS1339............................................................................................................. 34Manufacturing Range to SANS 1339 ............................................................................................................................... 35Type of Cables to SANS 1339.......................................................................................................................................... 36Construction of Cables to SANS 1339.............................................................................................................................. 37Properties and applications .............................................................................................................................................. 38Tirupati Type A - Three Core ............................................................................................................................................ 39-40
Tirupati Type A - Single Core........................................................................................................................................... 41-42
Tirupati Type B - Three Core ............................................................................................................................................ 43-44
Fault rating - kA for 1 sec (Copper) .................................................................................................................................. 45Fault rating - kA for 1 sec (Aluminium) .............................................................................................................................. 46Rating Factors ................................................................................................................................................................... 47-48TABLE 1 3.8 / 6.6 KV HT XLPE SINGLE CORE ALUMINIUM CONDUCTOR CABLES to IS : 7098 (Part-2)......................49TABLE 2 3.8 / 6.6 KV (E) HT XLPE SINGLE CORE COPPER CONDUCTOR CABLES...................................................... 49TABLE 3 6.35 / 11 KV 6.6/11 KV (UE) HT XLPE SINGLE CORE ALUMINIUM CONDUCTOR CABLES........................... 50TABLE 4 6.35 / 11 KV 6.6/6.6 KV (UE) HT XLPE SINGLE CORE COPPER CONDUCTOR CABLES................................. 50TABLE 11-11 / 11 KV (UE) HT XLPE SINGLE CORE ALUMINIUM CONDUCTOR CABLES............................................. 51TABLE 12 - 11 / 11 KV (UE) HT XLPE SINGLE CORE COPPER CONDUCTOR CABLES................................................. 51TABLE 13 - 12.7 / 22 KV HT XLPE SINGLE CORE ALUMINIUM CONDUCTOR CABLES................................................. 52TABLE 14 - 12.7 / 22 KV HT XLPE SINGLE CORE COPPER CONDUCTOR CABLES.......................................................52TABLE 15 - 19 / 33 KV HT XLPE SINGLE CORE ALUMINIUM CONDUCTOR CABLES................................................... 53TABLE 16 - 19 / 33 KV HT XLPE SINGLE CORE COPPER CONDUCTOR CABLES......................................................... 53TABLE 17 - 33 / 33 KV (UE) HT XLPE SINGLE CORE ALUMINIUM CONDUCTOR CABLES........................................... 54TABLE 18 - 33 / 33 KV (UE) HT XLPE SINGLE CORE COPPER CONDUCTOR CABLES................................................. 54TABLE 19 - 1.9 / 3.3 KV (E) & 3.3/3.3 KV (UE) HT XLPE THREE CORE ALUMINIUM CONDUCTOR CABLES ............... 55TABLE 20 - 1.9 / 3.3 KV (E) & 3.3/3.3 KV (UE) HT XLPE THREE CORE COPPER CONDUCTOR CABLES...................... 55TABLE 21 - 3.8 / 6.6 KV (E) HT XLPE THREE CORE ALUMINIUM CONDUCTOR CABLES ............................................ 56TABLE 22 - 3.8 / 6.6 KV (E) HT XLPE THREE CORE COPPER CONDUCTOR CABLES................................................... 56TABLE 23 - 6.35 / 11 KV (E) HT XLPE THREE CORE ALUMINIUM CONDUCTOR CABLES ........................................... 57TABLE 24 - 6.35 / 11 KV (E) HT XLPE THREE CORE COPPER CONDUCTOR CABLES................................................. 57TABLE 25 - 11 / 11 KV (UE) HT XLPE THREE CORE ALUMINIUM CONDUCTOR CABLES ........................................... 58TABLE 26 - 11 / 11 KV (UE) HT XLPE THREE CORE COPPER CONDUCTOR CABLES.................................................. 58TABLE 27 - 12.7 / 22 KV (E) HT XLPE THREE CORE ALUMINIUM CONDUCTOR CABLES ........................................... 59TABLE 28 - 12.7 / 22 KV (E) HT XLPE THREE CORE COPPER CONDUCTOR CABLES................................................. 59TABLE 29 - 19 / 33 KV (E) HT XLPE THREE CORE ALUMINIUM CONDUCTOR CABLES ........................................... 60TABLE 30 - 19 / 33 KV (E) HT XLPE THREE CORE COPPER CONDUCTOR CABLES..................................................... 60TABLE 31 - 33 / 33 KV (UE) HT XLPE THREE CORE ALUMINIUM CONDUCTOR CABLES ........................................... 61TABLE 32 - 33 / 33 KV (UE) HT XLPE THREE CORE COPPER CONDUCTOR CABLES.................................................. 61Handling Storage and Laying of HT Cables .....................................................................................................................62-64
Conversion Table .............................................................................................................................................................. 65
CERTIFICATES
Medium Voltage Cables 1
Introduction ABOUT
MISSION
VISION
Awards & Recognition
POLICY
Tirupati Plastomatics Pvt. Ltd. A flagship company of Gemini Group of industries Jaipur India. The founder of the
company Mr. R.S. Gemini who is managing director & a well known industrialist & a renowned social worker.
Tirupati Plastomatics enjoys Status of an ISO-9001:2008, ISO 14001:2004, OHSAS-18001, BIS, SMEC Australia,
Scott Wilson-UK & SABS certified Company having a group turnover of Rs. 250.00 crores US$ 53.76 Million. The
company is one of the leading manufacturer of all kind of Manufacturing and Supply of PVC/XLPE LT & HT (up to
33kV) Fire Retardant/Polyethylene Insulated, Aluminium/Aluminium Alloy/Copper Conductor Cables,
Unsheathed/Sheathed, Armoured/Unarmoured, Screened/Unscreened Type Including Power, Control,
Submersible, Telecom, Coaxial, Radio Frequency, Computer, HF, VHF, UHF, Railway Signalling (Indoor/Outdoor)
Aerial Bunched LT & HT (Up to 33kV), PIJF Cables for Telecommunication Including (4/6 Quad) and Dry (4 Quad)
Cable, ACSR, AAC & AAAC Conductor (up to 400 kV) with own technical know-how for last ] 11 years being
widely used by Indian railways, utility service providers & private turnkey project executors in electricity
distribution, transmission & generation. Tirupati has a dedicated & well experienced team of techno commercial
experts.
In addition to serving Indian railways & electricity boards, Tirupati has also entered into overseas markets and
have executed orders of aerial bunched cables, LV underground cables & AAA conductors, ACSR conductors
as per IEC/VDE/DIN/SABS/ASTM/NF/BS specification to EDM, Mozambique, Mazare-E-Sharif power projects in
Afghanistan and to South African customers.
Guided by the philosophy ‘create the best to be followed by the rest’, Tirupati Plastomatics aims at building a
zero-defect product, which will give value satistaction to its huge clientele. Tirupati Plastomatics strongly believes
that learning and improving is a continuous process for the total growth of the company.
Tirupati Plastomatics Pvt. Ltd., the name for dedication, devotion, discipline, discrimination and determination
has made a substantial growth plan with Rupees 1000 Crores turnover projection by 2015.
• Arch of Excellence Award 2002, All
India Organizational Confederation,
New Delhi.
• Award from Business Initiative
Development Board 2004, New Delhi.
• Indian Achiever Award of Industrial
Excellence for year 2008.
Grow with customer by providing full customer satisfaction through quality product, support, timely deliveries &
new development, operate safe, healthy & clean environment. Comply with statutory requirements, all applicable
environment, health & safety legislation, prevention of ill health and injury, interests of all stakeholders, prevention
of pollution, and continual improvement in the effectiveness and performance of Integrated Management System
by improving process work practices and risk minimization through objective driven targets. Integrate quality
safety, health & environmental matters in all existing activities and future planning. Create & enhance awareness
among employees, society and other stakeholders about environment protection, minimization of waste, wise
use of energy, water & other natural resources, improve skill & competence of our employees and contractors so
as to enable them to demonstrate their involvement, for sound IMS performance.
2
Outer sheath/ Jacket
Testing of medium Voltage Power Cables
Routine Tests
Sample Tests
Our cables sheaths are made of an extruded layer of PVC or PE material and are in compliance with the requirements of
IEC 60502-2 and BS 7655 Specification. We are also capable of providing cable sheaths with special requirements to be:
- Termite retardant
- Oil & Gasoline retardant
- Ozone/ acid/ alkali retardent
- Flame retardant and in compliance with requirements of IEC 60332-1 and IEC 61034-2
- Low smoke Halogen Free and in compliance with requirements of BS 7211 and BS 6724
We Tirupati Plastomatics Cable Company, are capable of performing all standard routine tests and sample tests that are
normally carried out in accordance to IEC 6 0502-2 standards. We have all necessary equipment for such tests such as
high voltage labs and special ovens.
We are also capable of performing tests in accordance with international or national requirements as agree upon with
customers.
- Measurements of the Electrical Resistance of Conductors
- Partial Discharge Test.
- High Voltage Test
- Conductor Examination
- Check of Dimensions
- Hot Set Test for XLPE Insulations
Medium Voltage Cables
Medium Voltage Cables to IEC 60502-2 (Design and Construction
Single-core or three core cables consist of the following components:
Conductors are made of copper or aluminum. Conductor design is usually circular stranded, and compacted. Our
conductor design is in compliance with the requirements of IEC 60228 and BS 6360 Specification.
Triple extrusion of inner semi-conductor (conductor screen), XLPE insulation, and outer semi-conductor (insulation
screen) is applied. XPLE insulation is Water cured. XLPE insulation material is as per the requirements of IEC 60502-2 or
as per customer's requirements.
The metallic screen is usually made of copper wires or copper tape. Radial water sealing such as AL-Pe laminate and
longitudinal water sealing may be applied upon customer's request.
All cable cores are laid-up together with usage of non-hygroscopic filler material. These fillers are temperature
compatible with all different cable layers such insulation, bedding and sheath.
Armuor material can be either Aluminum for single core cables or Steel for multi-core cables. Armuor can be either wires
or tapes. Our cable armouring is in compliance with the requirements of IEC 60502-2 and BS 6622.
)
Conductor
Insulation
Metallic screen
Assembly
Armouring
Medium Voltage Cables 3
Medium Voltage Cables
Conductor
Conductor Screen
Insulation
Insulation Screen
Metallic Screen
Galvanized Steel Tape Armour
Other Sheath
3 Cores XLPE Cable
1 Core XLPE Cable
Conductor
Conductor Screen
Insulation
Insulation Screen
Metallic Screen
Filler
PVC Bedding
Galvanized Steel wire Armour(for Galvanized Steel Tape)
Other sheath
Conductor
Conductor Screen
Insulation
Insulation Screen
Copper Tape Screen
Filler
Mylar Tape
PVC Bedding
Steel Wire Armour
PVC Sheath
Conductor
Conductor Screen
Insulation
Insulation Screen
Metallic Screen
Other Sheath
1
2
3
4
5
6
7
8
9
10
Medium Voltage Cables 4
General Information
Selecting A Power Cables
Voltage
Standards
Variation in Production and Delivery option
Jacket Marking
The following factor are important when selecting a suitable cable construction which required to transport electrical
energy from the power station to the consumer:
- Maximum operating voltage - Voltage drop
- Insulation level - Length of line
- Frequency - - Mode for installation underground
- Load to be carried (direct or in ducts) in air
- Magnitude and duration of - Chemical and physical properties of soil
possible overload - Max. and min. ambient air temperature -
- Magnitude and duration of and soil temperatures
short-circuit current - Specification and requirement to be met
The standard rated voltage of a cable is denoted by Uo/ U(Um),
where
Uo : is the rated power-frequency voltage between conductor and earth or metallic screen.
U : is the rated power-frequency voltage between conductors.
Um : is the maximum continuously permissible operating voltage of a cable at any time or in any part of the network.
Note :
Cable design for 6/10 and 18/30 kV is applicable for 6.35/11 and 19/33 kV respectively.
The cable described in this catalogue are all standard types, and their performance has been proved in operation,
Construction and test are in accordance with the recommendation of IEC publications where applicable.
Power cables in accordance to other standards (e.g. BS, VDE, NEMA) can be manufactured upon customer's
request.
The provide data is approximate and subject to manufacturing tolerance Delivery length
tolerance is ± 5%
Standards embossed outer jacket marking consisting of :
1 - Name of manufacturer
2 - Type designation, size of conductor, rated voltage and standard.
3 - Continuous length marking every meter.
4 - Year of manufacture.
U /U KVo 3.6/6 6/10 8.7/15 12/20 18/30
24 3617.5127.2Um KV
Medium Voltage Cables 5
Laying Information
XLPE insulated cables for 6.0 up to 30 kV
Maximum Tensile Forces During Laying
Minimum Bending Radius During Installation
During laying, the bending radius should not be smaller than values given below.
The radius depends on the outer diameter (Do) of the cable.
P = Pull in N2A = Total cross section area in mm of all conductors (but not sceen or concentric conductor)
d = Outside diameter of the cable in mm2s = Permissible tensile stress of conductor in N/mm
2k = Empirically derived factor on N/mm
Means of pulling Types of cable FactorFormula
With the pulling stocking
Un-armouredcables P = s.A
s(Copper conductor)
2 = 30Nmms
(Alum. conductor)
2
= 50N/mm
Armoured cables 2P=k.d 2K= 9/mm
With the pulling head attached to the conductors
All types of cable P = s.A2s = 50N/mm
(Copper conductor)2s = 30N/mm
(Alum. conductor)
Types of CableMinimum Radius
During Laying Adjacent to joints or terminations
Single-core - Unarmored - Amoured
20 D
20 Do
o 15 D
12 Do
o
Three-core - Unarmored - Amoured
15 Do
12 Do
12 Do
10 Do
Medium Voltage Cables 6
Electrical Parameters of the Cables
oThe Maximum DC resistance values of conductors at 20 C are as per "IEC 60228" standard.
DC resistance per unit length of the conductor at other conductor temperature are given by:o
oR=Ro [1+α (t-20 C)] 20 C
where :
R = DC resistance at temperature t °C (Ω/ km)oRo = DC resistance at temperature 20 C (Ω/ km) (given in the relative tables for each type of cable)
ot = Conductor temperature Co ooα= Temperature coefficient at 20 C (1/ C) 20 C
oFor copper conductor α = 0.00393 20 C
oFor aluminum conductor α = 0.00403 20 C
The AC Resistance per unit length of the conductor (effective resistance) at its maximum operating temperature is made
up to the DC resistance at this temperature and the extra resistance which takes into account additional losses caused
by the current displacement in the conductor (Skin effect and Proximity effect). The AC resistance is given in the given in
the relative tables for each type of cable.
The values of the inductance for both multicores and three single core cables have been calculated based on the
following presumption equation.
L = K+0.2 in (2S/d) (mH/km)
where:
K = a constant relating to the conductor formation (mH/km)
D = the conductor diameter (mm)
S = axial spacing between conductors for cables in trefoil formation (mm)
= 1.26 x axial spacing between conductors for cables in flat formation (mm)
The values for inductance of single core cables have been calculated based on one cable diameter between cables in
flat formation
The Values of operating capacitance for cables have been calculated based on the following presumption :
where :
ε = Relative permativity of insulation r
D = External diameter of insulation (mm)
d = Conductor diameter (mm)
o90 C for continuous normal operation
o105 C for emergency overload conditionso250 C for short circuit conditions
DC Resistance of Conductor
A.C. Resistance of Conductor
Inductance
Operation Capacitance
Operating temperature for XLPE insulated cables:
C= r
18 In (D)d
mf/ km
Medium Voltage Cables 7
Charging Current
Dielectric Losses
Voltage Drop
Cable Short Circuit Current Capacity
The charging current is the capacitive current which flows when AC voltage is applied to the cable as a result of the
capacitance between the conductors and metallic screen. The value can be derived from the equation.
-6Ic = Uo ω C 10
where:
Uo = Voltage between phase and earth (V)
w = 2 πf (rad/s)
f = Frequency (Hz)
C = Capacitance to neutral (µF/ Km)
The dielectric losses of an AC cable are proportional to the capacitance, the frequency, the phase voltage and dielectric
power factor. They are given by:2 -6D= (2πf C Uo tanδ) 10 (watt/m/phase)
where:
f = Frequency Hz
C = Capacitance to neutral (µF/ Km)
Uo= Voltage between phase and earth (V)
tanδ = Dielectric power factor
when current flows in a cable conductor, there is a voltage drop between the ends of the conductor which is the product of
the impedance. The following equations should be used to calculated the voltage drop:
1- Single phase system
Vd = 2 (R cosφ+Xsinφ) (Volt/ amp/ meter)
2- Three phase system
Vd = √3 (Rcosφ+Xsinφ) (Volt/ amp/ meter)
where:
Vd = Voltage drop (V/am/m)
R = AC resistance of conductor at a maximum conductor temperature (Ω/km)
X = Inductive reactance of cable (Ω/km)
Cosφ = power factor of load
The permissible short-circuit as presented in tables 11to13 are calculated in accordance with IEC 724, 1982. Which are
based on the following conditions:
1- Short circuit starts from the maximum operating temperature.
2- Maximum temperature during short circuitoXLPE = 250 CoPVC = 160 C
3- Maximum short circuit current duration is 5 seconds The short circuit current (I) shall be calculated from the formula.
where:
I = Short circuit current (A.)
T = Duration of short circuit (second)
K = Constant for the material of the conductor2S = Area of conductor (mm )
oθ= Final temperature ( C)1
oθ= Initial temperature ( C)2
β= Reciprocal of the temperature
coefficient of resistance (α) of the conductor
2 2 2I (K S /T) In=q+b1
q+b2
(A)
8
CURRENT RATINGS
1- RECOMMENDATIONS FOR CURRENT RATINGS
The current rating of power cables is defined by the maximum intensity of current (in amperes), which can flow
continuously through the cable, under permanent loading conditions, without any risk of damaging the insulation or
deterioration of its electrical properties.
- Current carrying capacities have been calculated in accordance with IEC 60287 (calculation of the continuous current
rating of cables).
- The values given in the tables are valid for one circuit in three phase system under conditions specified. For grouping
cables rating factors must be used.
- It is to be observed that the current carrying capacities presented in TPPL technical data sheets are intended as a guide
to assist operating engineers in selecting cables for safety and reliability.
- Basic assumptions and conditions of installation:o* Ambient ground temperature : 20 Co* Ambient air temperature : 30 C
* Depth of cable burial : 1.0 mo* Thermal resistivity of soil : 120 C.Cm/W
- Cables in air are assumed to be protected from direct solar radiation.
- Single core cables are installed as indicated in the technical information tables. Spacing between cables in flat formation
is assumed to be one cable diameter.
- For three and four-core cables, it is usual to assume the same current carrying capacity for four cores cables as for three-
core cables. Our calculated values are based actually on three core cables. These values are suitable with enough
accuracy also for four cores cables in most cases. Only for large four cores cables in air the values may be found to be too
conservative, due to the large cable surface and consequent high heat dissipation factor.
- The inner diameter of ducts has been assumed to be least 1.5 times the diameter of the cables.
- To obtain the maximum current carrying capacity of a cable operating at different conditions from the standards, you
have to multiply the values of the current given in the technical information for the corresponding cable by the rating factors
mentioned in the tables from 1 to 10, as follow:
la = K ls in amperes t
where:
l : Current rating at actual operating conditions (amperes)a
i : Current rating at standard operating conditions (amperes)s
K : Rating factor given the in the tables 1 to 10.t
It has to be noted that Kt is the total rating factor : Kt =K1....K2.... Kn
You may have a multiplication of so many partial rating factors, as many as the difference of laying and operating
conditions from standard conditions.
Medium Voltage Cables
Medium Voltage Cables 9
Table 1RATING FACTORS K FOR VARIATION IN GROUND TEMPERATURE
oPVC cables rated 70 C 0.54
0.67
0.70
0.84
0.88
0.87
0.95
0.96
0.96
1.00
1.00
1.00
0.71
0.78
0.790.92
0.92
0.90
0.83
0.84
0.78
0.73
0.75
0.63
oPVC cables rated 85 C
oXLPE cables rated 90 C
20 35 4525 30 40 50 55oGROUND TEMPERATURE C
Table 2RATING FACTORS K FOR VARIATION IN AIR TEMPERATURE
oPVC cables rated 70 C 1.07 1.00
1.00
1.00
0.87 0.70
0.74
0.91
0.90 0.80
0.96
0.95 0.85
1.04
1.04
0.820.87 0.76
0.93 0.79 0.61
oPVC cables rated 85 C
oXLPE cables rated 90 C
25 40 5030 35 45 55oAIR TEMPERATURE C
Table 3RATING FACTORS K FOR VARIATION IN GROUND DEPTH
k 1.05 1.03 1.02 1.01 0.991.00 0.98
0.6 0.9 1.10.7 0.8 1.0 1.2DEPTH OF LAYING (m)
Table 4RATING FACTORS K FOR VARIATION IN SOIL RESISTIVITY
k 1.17 1.12 1.00 0.911.07 0.91 0.80 0.73
80 110 15090 100 120 200SOIL RESISTIVITY (oC.cm/W) 250
10
Table 5TREFOIL OR FLAT FORMATION DERATING FACTORS FOR THREE
SINGLE CORE CABLES LAID DIRECT IN GROUND
NUMBER
OF
CIRCUIT
NR FLAT FLAT FLATTREFOIL TREFOIL TREFOIL
TOUCHING SPACING = 0.15 M SPACING = 0.30 M
TREFOIL FORMATION FLAT FORMATION
SPACING SPACING SPACING SPACING
2
3
4
5
6
0.77
0.66
0.60
0.56
0.53
0.80
0.69
0.63
0.59
0.57
0.82
0.73
0.68
0.64
0.61
0.85
0.76
0.71
0.67
0.64
0.85
0.76
0.71
0.67
0.64
0.91
0.83
0.77
0.75
0.73
0.88
0.80
0.74
0.72
0.70
Table 6TREFOIL OR FLAT FORMATION DERATING FACTORS FOR MULTI-CORE CABLES
LAID DIRECT IN GROUND
NUMBER
OF
CABLES
NR FLAT FLAT FLATTREFOIL TREFOIL TREFOIL
TOUCHING SPACING = 0.15 M SPACING = 0.30 M
TREFOIL FORMATION FLAT FORMATION
2
3
4
5
6
0.81
0.69
0.62
0.58
0.54
0.81
0.70
0.63
0.60
0.56
0.87
0.76
0.72
0.66
0.63
0.87
0.78
0.74
0.70
0.67
0.91
0.84
0.81
0.78
0.76
0.91
0.82
0.77
0.73
0.70
L
L
L
L
L L L
L L L
Medium Voltage Cables
Medium Voltage Cables 11
Table 7FLAT FORMATION DERATING FACTORS FOR THREE SINGLE CORE CABLES
LAID IN FREE AIR
Clearance = Cable diameter (d)
Clearance = from the wall 2 Cm
Laid on the Floor
1
0.92 0.880.89
32
0.92
0.87
0.84
0.82
0.89
0.84
0.82
0.80
0.88
0.83
0.81
0.79
Number of troughs1
2
3
6
Laid of cables
troughs
(circulation of air is
restricted)
Number of racks1
2
3
6
1.00
0.97
0.96
0.94
0.94
0.89
0.97
0.94
0.93
0.91
0.91
0.86
0.96
0.93
0.92
0.90
0.89
0.84
Laid
on cable racks
Arranged near the wall
Arranged on the wall
Table 8TREFOIL TOUCHING FORMATION DERATING FACTORS FOR THREE SINGLE
CORE CABLES LAID IN FREE AIR
Clearance = 2 (d)
Clearance from the wall 2 cm
Laid on the Floor
1
0.95 0.880.90
32
0.95
0.90
0.88
0.86
0.90
0.85
0.83
0.81
0.88
0.83
0.81
0.79
Number of troughs1
2
3
6
Laid of cables
troughs
(circulation of air is
restricted)
Number of racks1
2
3
6
1.00
1.00
1.00
1.00
0.98
0.95
0.94
0.93
0.96
0.93
0.92
0.90
Laid
on cable racks
Arrangements for
which reduction
of the current is not
necessary
Number of circuit
Number of circuit
³ 2 cm
d
d
³ 2 cm
d d
³ 3
0 c
m
d
³ 2 cm
d
³ 3
0 c
m
d d
³ 2 cm
d
d
³ 2 cm
2d2d
³ 2 cm
³ 3
0 c
m
2d2d
³ 3
0 c
m³ 3
0 c
m
4d2d
12
Table 9HORIZONTAL OR VERTICAL FORMATION DERATING FACTORS FOR
MULTI-CORE CABLES LAID IN FREE AIR
Clearance = Cable diameter (d)
Clearance from the wall 2 cm
Laid on the Floor
Number of troughs1
2
3
6
Laid of cables
troughs
(circulation of air is
restricted)
Number of racks1
2
3
6
0.95
0.95
0.90
0.88
0.86
0.90
0.85
0.83
0.81
0.88
0.83
0.81
0.79
0.85
0.81
0.79
0.77
0.84
0.80
0.78
0.76
1.00
1.00
1.00
1.00
1.00
Laid
on cable racks
Arranged near the wall
Arrangements
for which reduction
of the current
is not necessary
Number of Cables
1 2 3 4 5 6 9
0.90 0.88 0.85 0.84
0.98
0.95
0.94
0.93
0.93
0.96
0.93
0.92
0.90
0.90
0.93
0.90
0.89
0.87
0.87
0.92
0.89
0.88
0.86
0.86
Clearance
from the
wall
≥ 2cm
Clearance
between
cables
≥ 2 d
Table 10DERATING FACTORS FOR MULTI-CORE CABLES TOUCHING AND
IN CONTACT WITH THE WALL IN FREE AIR
Clearance touching troughs
and contact with wall
Laid on the Floor
Number of troughs1
2
3
6
Laid of cables
troughs
(circulation of air is
restricted)
0.90
0.95
0.95
0.95
0.95
0.84
0.80
0.78
0.76
0.80
0.76
0.74
0.72
0.75
0.71
0.70
0.68
0.73
0.69
0.68
0.66
Number of Cables
1 2 3 4 5 6 9
0.84 0.80 0.75 0.73
Number of racks1
2
3
6
0.95
0.95
0.95
0.95
0.95
Laid
on cable racks
Arranged on the wall
0.84
0.80
0.78
0.76
0.78
0.80
0.76
0.74
0.72
0.73
0.75
0.71
0.70
0.68
0.68
0.73
0.69
0.68
0.66
0.66
³ 2 cm d d
d
³ 3
0 c
m
³ 2 cm d
³ 3
0 c
m
d
³ 2 cm
³ 2 cm d
2d
d
2d³ 2 cm
³ 3
0 c
m³
30
cm
Medium Voltage Cables
Medium Voltage Cables 13
Table 13 o(90/250 C)
Table 11 o(90/250 C)
Area2(mm )
0.1 0.3 0.4 10.5 2 43 50.2
SHORT CIRCUIT CURRENT FOR COPPER CONDUCTORS - XLPE INSULATED (KA)
TIME (S)
2.29
3.58
5.01
7.15
10.02
13.59
17.17
21.46
26.47
34.34
42.93
1.62
2.53
3.54
5.06
7.08
9.61
12.14
15.18
18.72
24.28
30.35
1.32
2.07
2.89
4.13
5.78
7.85
9.91
12.39
15.28
19.83
24.78
3.62
5.66
7.92
11.31
15.84
21.49
27.15
33.94
41.85
54.30
67.87
3.24
5.06
7.08
10.11
14.16
19.22
24.28
30.35
37.43
48.56
60.71
4.18
6.53
9.14
13.06
18.29
24.82
31.34
39.19
48.33
62.70
78.37
7.24
11.31
15.84
22.62
31.67
42.98
54.30
67.87
83.71
108.59
135.74
16
25
35
50
70
95
120
150
185
240
300
1.14
1.79
2.50
3.58
5.01
6.80
8.59
10.73
13.24
17.17
21.46
5.12
8.00
11.20
16.00
22.40
30.39
38.39
47.99
59.19
76.79
95.98
1.02
1.60
2.24
3.20
4.48
6.08
7.68
9.60
11.94
15.36
19.20
Table 12 o(90/250 C)
Area2(mm )
0.1 0.3 0.4 10.5 2 43 50.2
SHORT CIRCUIT CURRENT FOR ALUMINUM CONDUCTORS - XLPE INSULATED (KA)
TIME (S)
1.51
2.36
3.31
4.72
6.61
8.98
11.34
14.17
17.48
22.68
28.35
1.07
1.67
2.34
3.34
4.68
6.35
8.02
10.02
12.36
16.03
20.04
0.87
1.36
1.91
2.73
3.82
5.18
6.55
8.18
10.09
13.09
16.37
2.39
3.73
5.23
7.47
10.46
14.19
17.93
22.41
27.64
35.85
44.82
2.14
3.34
4.68
6.68
9.35
12.69
16.03
20.04
24.72
32.07
40.09
2.76
4.31
6.04
8.63
12.08
16.39
20.70
25.88
31.91
41.40
51.75
4.78
7.47
10.46
14.94
20.91
28.38
35.85
44.82
55.28
71.71
89.64
16
25
35
50
70
95
120
150
185
240
300
0.76
1.18
1.65
2.36
3.31
4.49
5.67
7.09
8.74
11.34
14.17
3.38
5.28
7.40
10.56
14.79
20.07
25.35
31.69
39.09
50.71
63.38
0.68
1.06
1.48
2.11
2.96
4.01
5.07
6.34
7.82
10.14
12.68
Area2(mm )
SHORT CIRCUIT CURRENT FOR COPPER SCREEN (KA)
TIME (S)
0.1 0.3 0.4 10.5 2 43 50.2
1.62
2.53
3.54
1.32
2.07
2.89
3.62
5.66
7.92
2.29
3.58
5.01
4.18
6.53
9.14
7.24
11.31
15.84
16
25
35
1.14
1.79
2.50
5.12
8.00
11.20
1.02
1.60
2.24
3.24
5.06
7.08
14
Single Core CableFor installations outdoor in ground, in ducts and indoor on trays.
CU/XLPE/PVC, 3.6/6 KVIEC 60502-2Circular stranded Compacted copper (or Aluminum)Bonded semiconducting materialXLPE material Strippable semiconducting material (or Bonded)Annealed copper wires or (copper tape)PVC compound (or LSHF or PE)
Type :Standard :Conductor :Conductor Screen :Insulation :Insulation Screen :Metallic Screen :Jacketing :
2. Electrical Data
Cross section Area
Screen Area
oDC Resist at 20 CoAc Resist at 90 C
Inductance
Flat Formation
Trefoil Formation
Capacitance
Charging current
Dielectic losses
Current Ampacity
Cable in ground
Cable in free air
Short circuit current
Conductor S.C (1 Sec)
Screen S.C (1 Sec)
2525 35 50 70 95 150 240 400 500 630120 185 300
0.495
0.449
0.467
0.421
0.440
0.394
0.417
0.371
0.400
0.353
0.384
0.338
0.380
0.331
0.368
0.322
0.355
0.420
0.349
0.303
0.345
0.299
0.338
0.292
0.328
0.283
0.269
0.365
0.306
0.415
0.337
0.457
0.385
0.522
0.430
0.583
0.472
0.640
0.514
0.697
0.558
0.758
0.606
0.823
0.617
0.838
0.646
0.876
0.672
0.912
0.751
1.019
0.011 0.012 0.013 0.015 0.017 0.018 0.020 0.022 0.024 0.024 0.025 0.026 0.029
170
180
195
210
235
245
265
285
305
355
345
410
395
470
455
540
500
630
560
720
635
840
710
960
790
1100
2mm
2mm
W / km
W / km
mh/ km
mh/ km
mF/ km
A/ km
W/m
A
A
KA
KA
5.01
2.29
5.0
2.29
7.15
2.29
10.0
2.29
13.5
2.29
17.1
2.29
21.4
3.58
26.4
3.58
34.4
3.58
42.9
3.58
57.2
5.07
71.5
5.07
90.0
5.07
16
0.727
0.927
16
0.524
0.668
16
0.387
0.494
16
0.268
0.342
16
0.193
0.247
16
1.53
0.196
25
0.124
0.160
25
0.0991
0.1290
25
0.0754
0.099
25
0.0601
0.0812
35
0.0470
0.0657
35
0.366
0.0538
35
0.028
0.045
TECHNICAL INFORMATION1. Weight and Dimension Data
Nominal Cross
Section
2n x mm
Nominal Insulation Thickness
mm
Approx.Cable
Weight
kg/km
Approx.Overall
Diameter
mm
Nominal Sheath
Thickness
mm
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500
1x630
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.6
2.8
3.0
3.2
3.2
640
764
897
1126
1403
1657
2033
2387
2978
3610
4499
5497
7108
20.3
21.6
22.3
24.5
25.4
28.0
29.6
31.8
34.4
36.6
40.5
44.5
47.9
1.5
1.6
1.6
1.6
1.7
1.8
1.8
1.9
1.9
2.0
2.2
2.3
2.4
Medium Voltage Cables
Medium Voltage Cables 15
Three Core CableFor installations outdoor in ground, in ducts and indoor on trays.
CU/XLPE/PVC, 3.6/6 KVIEC 60502-2Circular stranded Compacted copper (or Aluminum)Bonded semiconducting materialXLPE material Strippable semiconducting material (or Bonded)Copper tape (or copper wires)PVC compound (or LSHF or PE)PVC compound (or LSHF or PE)
Type :Standard :Conductor :Conductor Screen :Insulation :Insulation Screen :Metallic Screen :Bedding :Jacketing :
2. Electrical Data
Cross section Area
Screen Area
oDC Resist at 20 CoAc Resist at 90 C
Inductance
Capacitance
Charging current
Dielectic losses
Current Ampacity
Cable in ground
Cable in free air
Short circuit current
Conductor S.C (1 Sec)
Screen S.C (1 Sec)
2mm
2mm
W / km
16 25 35 50 70 120 185 300 400 50095 150 240
W / km
mF/ km
A/ km
W/m
A
A
115
120
160
172
191
203
224
235
255
275
300
335
340
390
385
445
435
510
495
580
555
665
625
760
700
890
KA
KA
2.3
2.29
3.57
2.29
5.0
2.29
7.15
2.29
10.0
2.29
13.5
2.29
17.17
2.29
21.4
3.58
26.4
3.58
34.4
3.58
42.9
3.58
57.2
5.07
71.5
5.07
16
1.150
1.466
0.422
0.241
0.314
0.010
16
0.727
0.927
0.402
0.269
0.365
0.011
16
0.524
0.668
0.379
0.306
0.415
0.012
16
0.387
0.494
0.422
0.337
0.457
0.013
16
0.268
0.342
0.330
0.385
0.522
0.015
16
0.193
0.247
0.310
0.430
0.583
0.017
16
0.153
0.196
0.300
0.472
0.640
0.018
25
0.124
0.160
0.290
0.514
0.697
0.020
25
0.0991
0.1290
0.280
0.558
0.758
0.022
25
0.0754
0.099
0.270
0.606
0.823
0.024
25
0.0601
0.0812
0.266
0.617
0.838
0.024
35
0.04700
0.0657
0.261
0.646
0.876
0.025
35
0.0366
0.0538
0.256
0.672
0.912
0.026
mh/ km
TECHNICAL INFORMATION1. Weight and Dimension Data
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
3.0
3.2
3.5
3.7
Nominal Sheath
Thickness
mm
39.8
42.7
45.5
49.6
53.0
56.9
60.4
64.6
70.1
75.4
83.6
90.3
Approx.Overall
Diameter
mm
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.6
2.8
3.0
3.2
mm
Nominal Insulation Thickness
3 x 25
3 x 35
3 x 50
3 x 70
3 x 95
3 x 120
3 x 150
3 x 185
3 x 240
3 x 300
3 x 400
3 x 500
Nominal Cross
Section 2n x mm
1943
2360
2885
3649
4587
5484
6461
7635
9639
11806
14654
17897
Approx.Cable
Weight
kg/km
16
Three Core CableFor Installations outdoor in ground, in ducts and indoor on trays.
CU/XLPE/STA/PVC, 3.6/6 KVIEC 60502-2Circular stranded Compacted copper (or Aluminum)Bonded semiconducting materialXLPE material Strippable semiconducting material (or Bonded)Copper tape (or copper wires)PVC compound (or LSHF or PE)Galvanized steel tapePVC compound (or LSHF or PE)
Type :Standard :Conductor :Conductor Screen :Insulation :Insulation Screen :Metallic Screen :Bedding :Armoring :Jacketing :
2. Electrical Data
Cross section Area
Screen Area
oDC Resist at 20 CoAc Resist at 90 C
Inductance
Capacitance
Charging current
Dielectic losses
Current Ampacity
Cable in ground
Cable in free air
Short circuit current
Conductor S.C (1 Sec)
Screen S.C (1 Sec)
2mm
2mm
W / km
16
16
1.150
1.466
0.422
0.241
0.314
0.010
25
16
0.727
0.927
0.400
0.269
0.365
0.011
35
16
0.524
0.668
0.366
0.306
0.415
0.012
50
16
0.387
0.494
0.342
0.337
0.457
0.013
70
16
0.268
0.342
0.323
0.385
0.522
0.015
95
16
0.193
0.247
0.310
0.430
0.583
0.017
120
16
0.153
0.196
0.300
0.472
0.640
0.018
150
25
0.124
0.160
0.290
0.514
0.697
0.020
185
25
0.0991
0.1290
0.280
0.558
0.758
0.022
240
25
0.0754
0.099
0.270
0.606
0.823
0.024
300
25
0.0601
0.0812
0.266
0.617
0.838
0.024
400
35
0.0470
0.0657
0.261
0.646
0.876
0.025
500
35
0.0366
0.0538
0.256
0.672
0.912
0.026
W / km
mF/ km
A/ km
W/m
A
A
114
120
2.3
2.29
157
170
3.57
2.29
187
198
5.0
2.29
219
230
7.15
2.29
248
281
10.0
2.29
297
335
13.5
2.29
336
390
17.17
2.29
379
445
21.4
3.58
425
495
26.4
3.58
485
575
34.4
3.58
540
650
42.9
3.58
612
745
57.2
5.07
680
860
71.5
5.07
KA
KA
mh/ km
TECHNICAL INFORMATION1. Weight and Dimension Data
Nominal Cross
Section
2n x mm
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.6
2.8
3.0
3.2
39.6
41.4
44.0
47.3
51.2
54.7
58.7
62.3
66.1
71.0
77.1
87.6
95.2
2097
2580
3014
4456
5449
6415
7444
8683
9420
10794
13069
16566
19895
2.1
2.2
2.2
2.3
2.5
2.6
2.7
2.8
2.9
3.1
3.3
3.6
3.8
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.8
0.8
3x16
3x25
3x50
3x70
3x95
3x95
3x120
3x150
3x185
3x240
3x300
3x400
3x500
Nominal Insulation Thickness
mm
Approx.Overall
Diameter
mm
Approx.Cable
Weight
kg/ km
Nominal Sheath
Thickness
mm
SteelTape
Thickness
mm
Medium Voltage Cables
Medium Voltage Cables 17
Three Core CableFor Installations outdoor in ground, in ducts and indoor on trays.
CU/XLPE/SWA/PVC, 3.6/6 KVIEC 60502-2Circular stranded Compacted copper (or Aluminum)Bonded semiconducting materialXLPE material Strippable semiconducting material (or Bonded)Copper tape (or copper wires)Galvanized steel WirePVC compound (or LSHF or PE)PVC compound (or LSHF or PE)
Type :Standard :Conductor :Conductor Screen :Insulation :Insulation Screen :Metallic Screen :Armoring :Bedding :Jacketing :
2. Electrical Data
Cross section Area
Screen Area
oDC Resist at 20 CoAc Resist at 90 C
Inductance
Capacitance
Charging current
Dielectic losses
Current Ampacity
Cable in ground
Cable in free air
Short circuit current
Conductor S.C (1 Sec)
Screen S.C (1 Sec)
2mm
2mm
W / km
16
16
1.150
1.466
0.422
0.241
0.314
0.010
25
16
0.727
0.927
0.400
0.269
0.365
0.011
35
16
0.524
0.668
0.366
0.306
0.415
0.012
50
16
0.387
0.494
0.342
0.337
0.457
0.013
70
16
0.268
0.342
0.323
0.385
0.522
0.015
95
16
0.193
0.247
0.309
0.430
0.583
0.017
120
16
0.153
0.196
0.296
0.472
0.640
0.018
150
25
0.124
0.160
0.288
0.514
0.697
0.020
185
25
0.0991
0.1290
0.280
0.558
0.758
0.022
240
25
0.0754
0.099
0.270
0.606
0.823
0.024
300
25
0.0601
0.0812
0.266
0.617
0.838
0.024
400
35
0.0470
0.0657
0.261
0.646
0.876
0.025
500
35
0.0366
0.0538
0.256
0.672
0.912
0.026
W / km
mF/ km
A/ km
W/m
A
A
114
120
2.3
2.29
158
172
3.57
2.29
188
199
5.0
2.29
220
230
7.15
2.29
249
282
10.0
2.29
298
336
13.5
2.29
337
392
17.17
2.29
380
447
21.4
3.58
426
495
26.4
3.58
485
575
34.4
3.58
541
650
42.9
3.58
613
746
57.2
5.07
681
862
71.5
5.07
KA
KA
mh/ km
TECHNICAL INFORMATION1. Weight and Dimension Data
Nominal Cross
Section
Nominal Insulation Thickness
SteelWire
Diameter
Nominal Sheath
Thickness
Approx.Overall
Diameter
Approx.Cable
Weight2n x mm mm mm mm mm kg/ km
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.6
2.8
3.0
3.2
2.00
2.00
2.50
2.50
2.50
2.50
2.50
2.50
2.50
3.15
3.15
3.15
3.15
2.2
2.3
2.3
2.5
2.6
2.8
2.8
2.9
3.1
3.2
3.5
3.7
4.0
40.9
43.5
46.6
49.8
53.9
58.0
64.9
65.4
69.9
75.5
82.8
89.9
98.4
2952
3404
3928
5037
5972
7084
8165
9273
10357
12938
16493
19858
23192
3x16
3x25
3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x300
3x400
3x500
18
Single Core CableFor Installations outdoor in ground, in ducts and indoor on trays.
CU/XLPE/PVC, 6/10 KVIEC 60502-2Circular stranded Compacted copper (or Aluminum)Bonded semiconducting materialXLPE material Strippable semiconducting material (or Bonded)Annealed Copper Wire (or Copper Tape)PVC compound (or LSHF or PE)
Type :Standard :Conductor :Conductor Screen :Insulation :Insulation Screen :Metallic Screen :Jacketing :
TECHNICAL INFORMATION1. Weight and Dimension Data
mmmm2n x mm mm kg/km
Nominal Insulation Thickness
Nominal Sheath
Thickness
Nominal Cross
Section
Approx.Cable
Weight
Approx.Overall
Diameter
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500
1x630
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
722
835
990
1211
1505
1752
2144
2495
3091
3706
4632
5605
7149
1.6
1.6
1.7
1.7
1.8
1.8
1.9
1.9
2.0
2.1
2.2
2.3
2.4
22.4
23.8
25.0
26.6
27.4
29.9
31.4
33.9
35.5
38.7
41.9
45.0
49.8
2. Electrical Data
Cross section Area
Screen Area
oDC Resist at 20 CoAc Resist at 90 C
Inductance
Flat Formation
Trefoil Formation
Capacitance
Charging current
Dielectic losses
Current Ampacity
Cable in ground
Cable in free air
Short circuit current
Conductor S.C (1 Sec)
Screen S.C (1 Sec)
2mm
2mm
W / km
35
16
0.524
0.668
25
16
0.727
0.927
50 70 95 150 240 400 500 630120 185 300
W / km
mh/ km
mh/ km
0.483
0.437
0.512
0.466
0.474
0.410
0.433
0.385
mF/ km
A/ km
0.240
0.544
0.213
0.482
0.264
0.596
0.299
0.676
W/m 0.023 0.026 0.029 0.032
A
A
170
180
195
210
235
245
265
285
KA
KA
3.57
2.29
5.0
2.29
7.15
2.29
10.0
2.29
16
0.387
0.494
16
0.268
0.342
0.417
0.368
0.400
0.352
0.393
0.344
0.382
0.334
0.367
0.319
0.352
0.310
0.340
0.294
0.330
0.282
0.347
0.302
0.332
0.751
0.363
0.822
0.394
0.892
0.427
0.966
0.479
1.083
0.520
1.176
0.636
1.439
0.711
1.607
0.577
1.306
0.036 0.039 0.043 0.046 0.052 0.056 0.069 0.0770.063
305
355
345
410
395
470
455
540
500
630
560
720
710
960
790
1100
635
840
13.5
2.29
17.1
2.29
21.4
3.58
26.4
2.29
34.4
3.58
42.9
3.58
71.5
5.07
90.0
5.07
57.2
5.07
16
0.193
0.247
16
0.153
0.196
25
0.124
0.160
25
0.0991
0.1290
25
0.0754
0.099
25
0.0601
0.0812
35
0.0366
0.0538
35
0.0283
0.0452
35
0.0470
0.0657
Medium Voltage Cables
Medium Voltage Cables 19
Three Core CableFor Installations outdoor in ground, in ducts and indoor on trays.
CU/XLPE/PVC, 6/10 KVIEC 60502-2Circular stranded Compacted copper (or Aluminum)Bonded semiconducting materialXLPE material Strippable semiconducting material (or Bonded)Copper tape (or copper wires)PVC compound (or LSHF or PE)PVC compound (or LSHF or PE)
Type :Standard :Conductor :Conductor Screen :Insulation :Insulation Screen :Metallic Screen :Bedding :Jacketing :
2. Electrical Data
Cross section Area
Screen Area
oDC Resist at 20 CoAc Resist at 90 C
Inductance
Capacitance
Charging current
Dielectic losses
Current Ampacity
Cable in ground
Cable in free air
Short circuit current
Conductor S.C (1 Sec)
Screen S.C (1 Sec)
2mm
2mm
W / km
16
16
1.150
1.466
0.447
0.192
0.314
0.019
25
16
0.727
0.927
0.413
0.213
0.482
0.023
35
16
0.524
0.668
0.387
0.240
0.544
0.026
50
16
0.387
0.494
0.362
0.264
0.596
0.029
70
16
0.268
0.342
0.341
0.299
0.676
0.032
95
16
0.193
0.247
0.325
0.332
0.751
0.036
120
16
0.153
0.196
0.312
0.363
0.822
0.039
150
25
0.124
0.160
0.302
0.394
0.892
0.043
185
25
0.0991
0.1291
0.300
0.427
0.966
0.046
240
25
0.0754
0.099
0.280
0.479
1.083
0.052
300
25
0.0601
0.0814
0.274
0.520
1.176
0.056
400
35
0.0470
0.0659
0.265
0.577
1.306
0.063
500
35
0.0366
0.0543
0.259
0.636
1.439
0.069
W / km
mF/ km
A/ km
W/m
A
A
115
120
2.3
2.29
161
173
3.57
2.29
180
199
5.0
2.29
210
230
7.15
2.29
253
275
10.0
2.29
302
335
13.5
2.29
340
390
17.17
2.29
387
447
21.4
3.58
430
505
26.4
3.58
493
578
34.4
3.58
555
665
42.9
3.58
628
758
57.2
5.07
700
890
71.5
5.07
KA
KA
mh/ km
TECHNICAL INFORMATION1. Weight and Dimension Data
Nominal Cross
Section
Nominal Sheath
Thickness
Approx.Cable
Weight
Nominal Insulation Thickness
Approx.Overall
Diameter
3x16
3x25
3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x300
3x400
3x500
2.2
2.2
2.3
2.4
2.5
2.7
2.8
2.9
3.0
3.1
3.3
3.5
3.7
1807
2213
2686
3181
3973
5012
5877
6876
8073
10112
12121
14860
18013
3.4
3.3
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
41.1
43.2
46.5
49.2
53.0
57.2
60.5
64.1
66.9
73.0
78.5
85.1
91.6
2n x mm mmmm mm kg/km
20
Three Core CableFor Installations outdoor in ground, in ducts and indoor on trays.
CU/XLPE/ STA/ PVC, 6/10 KVIEC 60502-2Circular stranded Compacted copper (or Aluminum)Bonded semiconducting materialXLPE material Strippable semiconducting material (or Bonded)Copper tape (or copper wire)PVC compound (or LSHF or PE)Galvanized steel tapePVC compound (or LSHF or PE)
Type : Standard :Conductor :Conductor Screen :Insulation :Insulation Screen :Metallic Screen :Bedding :Armoring :Jacketing :
2. Electrical Data
Cross section Area
Screen Area
oDC Resist at 20 CoAc Resist at 90 C
Inductance
Capacitance
Charging current
Dielectic losses
Current Ampacity
Cable in ground
Cable in free air
Short circuit current
Conductor S.C (1 Sec)
Screen S.C (1 Sec)
2mm
2mm
W / km
16
16
1.150
1.466
0.447
0.192
0.569
0.019
25
16
0.727
0.927
0.413
0.213
0.482
0.023
35
16
0.524
0.668
0.387
0.240
0.544
0.026
50
16
0.387
0.494
0.362
0.264
0.596
0.029
70
16
0.268
0.342
0.341
0.299
0.676
0.032
95
16
0.193
0.247
0.326
0.332
0.751
0.036
120
16
0.153
0.196
0.312
0.363
0.822
0.039
150
25
0.124
0.160
0.302
0.394
0.892
0.043
185
25
0.0991
0.1291
0.300
0.427
0.966
0.046
240
25
0.0754
0.099
0.281
0.479
1.038
0.054
300
25
0.0601
0.0814
0.274
0.520
1.176
0.056
400
35
0.0470
0.0659
0.265
0.577
1.306
0.063
500
35
0.0366
0.0543
0.259
0.636
1.439
0.069
W / km
mF/ km
A/ km
W/m
A
A
115
125
2.3
2.29
159
172
3.57
2.29
175
195
5.0
2.29
205
232
7.15
2.29
250
232
10.0
2.29
295
340
13.5
2.29
335
390
17.11
2.29
380
446
21.4
3.58
420
495
26.4
3.58
482
570
34.3
3.58
540
650
42.9
3.58
612
745
57.2
5.07
682
863
71.5
5.07
KA
KA
mh/ km
TECHNICAL INFORMATION1. Weight and Dimension Data
Nominal Sheath
Thickness
mm
SteelTape
Thickness
mm
Nominal Insulation Thickness
mm
Nominal Cross
Section
2n x mm
Approx.Overall
Diameter
mm
Approx.Cable
Weight
kg/ km
2.3
2.4
2.4
2.5
2.6
2.7
2.8
2.9
3.1
3.2
3.4
3.6
3.8
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3x16
3x25
3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x300
3x400
3x500
43.1
45.4
48.0
51.3
55.2
59.4
62.7
66.0
69.0
76.2
79.9
88.4
95.0
2423
2910
3439
3992
4843
5921
6850
7902
9163
11341
13440
17082
20399
Medium Voltage Cables
Medium Voltage Cables 21
Three Core CableFor Installations outdoor in ground and ducts, and indoor on trays, in walls, and in ducts.
CU/XLPE/SWA/PVC, 6/10 KVIEC 60502-2Circular stranded Compacted copper (or Aluminum)Bonded semiconducting materialXLPE material Strippable semiconducting material (or Bonded)Copper tape (or copper wire)PVC compound (or LSHF or PE)Galvanized steel wiresPVC compound (or LSHF or PE)
Type :Standard :Conductor :Conductor Screen :Insulation :Insulation Screen :Metallic Screen :Bedding :Armoring :Jacketing :
2. Electrical Data
Cross section Area
Screen Area
oDC Resist at 20 CoAc Resist at 90 C
Inductance
Capacitance
Charging current
Dielectic losses
Current Ampacity
Cable in ground
Cable in free air
Short circuit current
Conductor S.C (1 Sec)
Screen S.C (1 Sec)
2mm
2mm
W / km
16
16
1.150
1.466
0.447
0.192
0.314
0.019
25
16
0.727
0.927
0.413
0.213
0.482
0.023
35
16
0.524
0.668
0.387
0.240
0.544
0.026
50
16
0.387
0.494
0.362
0.264
0.596
0.029
70
16
0.268
0.342
0.341
0.299
0.676
0.032
95
16
0.193
0.247
0.326
0.332
0.751
0.036
120
16
0.153
0.196
0.312
0.363
0.822
0.039
150
25
0.124
0.160
0.302
0.394
0.892
0.043
185
25
0.0991
0.1290
0.294
0.427
0.966
0.046
240
25
0.0754
0.0999
0.281
0.479
1.083
0.052
300
25
0.0601
0.0814
0.274
0.520
1.176
0.056
400
35
0.0470
0.0659
0.265
0.577
1.306
0.063
500
35
0.0366
0.0543
0.259
0.636
1.439
0.069
W / km
mF/ km
A/ km
W/m
A
A
115
125
2.3
2.29
160
172
3.57
2.29
175
199
5.0
2.29
205
230
7.15
2.29
245
285
10.0
2.29
295
336
13.5
2.29
330
392
17.11
2.29
375
446
21.4
3.58
418
487
26.4
3.58
470
568
34.3
3.58
525
635
42.9
3.58
590
735
57.2
5.07
640
820
71.5
5.07
KA
KA
mh/ km
TECHNICAL INFORMATION1. Weight and Dimension Data
Nominal Sheath
Thickness
SteelWire
Diameter
Nominal Insulation Thickness
Nominal Cross
Section
Approx.Overall
Diameter
Approx.Cable
Weight
mmmmmm2n x mm mm kg/ km
2.4
2.4
2.6
2.7
2.8
2.8
2.9
3.0
3.2
3.4
3.6
3.8
4.0
2.00
2.00
2.50
2.50
2.50
2.50
2.50
2.50
2.50
3.15
3.15
3.15
3.15
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3x16
3x25
3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x300
3x400
3x500
45.7
49.0
51.4
54.5
58.9
62.8
65.6
70.7
73.5
81.4
87.0
92.5
99.6
3415
4293
4904
5535
6492
7684
8728
9897
11308
14832
17097
20268
23783
22
Single Core CableFor Installations outdoor in ground, in ducts and indoor on trays.
CU/XLPE/PVC, 8.7/15 KVIEC 60502-2Circular stranded Compacted copper (or Aluminum)Bonded semiconducting materialXLPE material Strippable semiconducting material (or Bonded)Annealed Copper Wires (or LSHF or PE)PVC compound (or LSHF or PE)
Type :Standard :Conductor :Conductor Screen :Insulation :Insulation Screen :Metallic Screen :Jacketing :
2. Electrical Data
Cross section Area
Screen Area
oDC Resist at 20 CoAc Resist at 90 C
Inductance
Flat Formation
Trefoil Formation
Capacitance
Charging current
Dielectic losses
Current Ampacity
Cable in ground
Cable in free air
Short circuit current
Conductor S.C (1 Sec)
Screen S.C (1 Sec)
2mm
2mm
W / km
35
16
0.524
0.668
25
16
0.727
0.927
50 70 95 150 240 400 500 630120 185 300
W / km
mh/ km
mh/ km
0.504
0.457
0.534
0.486
0.475
0.427
0.451
0.402
mF/ km
A/ km
0.196
0.641
0.175
0.572
0.213
0.699
0.240
0.788
W/m 0.040 0.045 0.049 0.055
A
A
180
200
210
240
255
300
KA
KA
16
0.387
0.495
16
0.268
0.342
0.432
0.394
0.416
0.386
0.407
0.358
0.396
0.348
0.380
0.332
0.371
0.322
0.352
0.304
0.339
0.291
0.361
0.314
0.266
0.871
0.289
0.949
0.313
1.026
0.338
1.108
0.377
1.236
0.408
1.339
0.496
1.628
0.553
1.813
0.452
1.481
0.061 0.066 0.071 0.077 0.086 0.093 0.113 0.1260.103
305
360
345
415
390
475
430
540
500
635
560
730
710
960
790
1100
635
840
16
0.193
0.247
16
0.153
0.196
25
0.124
0.160
25
0.0991
0.1286
25
0.0754
0.0992
25
0.0601
0.0806
35
0.0366
0.0532
35
0.0283
0.0455
35
0.0470
0.0651
150
165
5.0
2.29
7.15
2.29
10.0
2.29
13.5
2.29
17.1
2.29
21.4
3.58
26.4
2.29
34.4
3.58
42.9
3.58
71.5
5.07
90.0
5.07
57.2
5.07
3.57
2.29
TECHNICAL INFORMATION1. Weight and Dimension Data
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500
1x630
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
1.7
1.7
1.7
1.8
1.8
1.9
2.0
2.0
2.1
2.2
2.3
2.4
2.5
797
915
1054
1293
1586
1857
2255
2537
3214
3848
4774
5766
7324
24.4
25.6
26.0
28.5
30.2
31.2
34.0
35.2
38.5
40.6
43.1
47.3
51.1
2n x mm mm kg/kmmm mm
Nominal Cross
Section
Nominal Sheath
Thickness
Approx.Cable
Weight
Nominal Insulation Thickness
Approx.Overall
Diameter
Medium Voltage Cables
Medium Voltage Cables 23
Three Core CableFor Installations outdoor in ground, in ducts and indoor on trays.
CU/XLPE/PVC, 8.7/15 KVIEC 60502-2Circular stranded Compacted copper (or Aluminum)Bonded semiconducting materialXLPE material Strippable semiconducting material (or Bonded)Copper Tape (or Copper Tape)PVC compound (or LSHF or PE)PVC compound (or LSHF or PE)
Type :Standard :Conductor :Conductor Screen :Insulation :Insulation Screen :Metallic Screen :Bedding :Jacketing :
2. Electrical Data
Cross section Area
Screen Area
oDC Resist at 20 CoAc Resist at 90 C
Inductance
Capacitance
Charging current
Dielectic losses
Current Ampacity
Cable in ground
Cable in free air
Short circuit current
Conductor S.C (1 Sec)
Screen S.C (1 Sec)
2mm
2mm
W / km
25
16
0.727
0.927
0.438
0.175
0.572
0.040
35
16
0.524
0.668
0.411
0.196
0.641
0.045
50
16
0.387
0.494
0.384
0.213
0.699
0.049
70
16
0.268
0.342
0.360
0.240
0.788
0.055
95
16
0.193
0.247
0.345
0.266
0.871
0.061
120
16
0.153
0.196
0.330
0.289
0.949
0.066
150
25
0.124
0.160
0.319
0.313
1.026
0.071
185
25
0.0991
0.1288
0.309
0.338
1.108
0.077
240
25
0.0754
0.0995
0.296
0.377
1.236
0.086
300
25
0.0601
0.0810
0.287
0.408
1.339
0.093
400
35
0.0470
0.0655
0.278
0.452
1.481
0.103
500
35
0.0366
0.0538
0.270
0.496
1.628
0.113
W / km
mF/ km
A/ km
W/m
A
A
148
160
3.57
2.29
175
195
5.0
2.29
205
230
7.15
2.29
250
280
10.0
2.29
300
340
13.5
2.29
340
390
17.1
2.29
380
440
21.4
3.58
425
505
26.4
3.58
493
585
34.3
3.58
555
665
42.9
3.58
630
765
57.2
5.07
695
885
71.5
5.07
KA
KA
mh/ km
TECHNICAL INFORMATION1. Weight and Dimension Data
kg/km2n x mm
Approx.Cable
Weight
Approx.Overall
Diameter
Nominal Sheath
Thickness
Nominal Insulation Thickness
Nominal Cross
Section
2633
3080
3604
4473
5462
6343
7361
8660
10701
12752
15547
18821
48.0
51.1
54.1
58.5
62.2
64.8
69.1
73.1
78.0
82.9
90.1
37.2
mm
2.4
2.5
2.6
2.7
2.8
2.9
3.0
3.1
3.3
3.5
3.7
3.9
mm
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
mm
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500
24
Three Core CableFor Installations outdoor in ground, in ducts and indoor on trays.
CU/XLPE/STA/PVC, 8.7/15 KVIEC 60502-2Circular stranded Compacted copper (or Aluminum)Bonded semiconducting materialXLPE material Strippable semiconducting material (or Bonded)Copper tapePVC compound (or LSHF or PE)Galvanized Steel TapePVC compound (or LSHF or PE)
Type :Standard :Conductor :Conductor Screen :Insulation :Insulation Screen :Metallic Screen :Bedding :Armoring :Jacketing :
2. Electrical Data
Cross section Area
Screen Area
oDC Resist at 20 CoAc Resist at 90
Inductance
Capacitance
Charging current
Dielectic losses
Current Ampacity
Cable in ground
Cable in free air
Short circuit current
Conductor S.C (1 Sec)
Screen S.C (1 Sec)
2mm
2mm
W / km
25
16
0.727
0.927
0.438
0.175
0.572
0.040
35
16
0.524
0.668
0.411
0.196
0.641
0.045
50
16
0.387
0.494
0.384
0.213
0.699
0.049
70
16
0.268
0.342
0.360
0.240
0.788
0.055
95
16
0.193
0.247
0.345
0.266
0.871
0.061
120
16
0.153
0.196
0.330
0.289
0.949
0.066
150
25
0.124
0.160
0.319
0.313
1.026
0.071
185
25
0.0991
0.1288
0.309
0.338
1.108
0.077
240
25
0.0754
0.0995
0.296
0.377
1.236
0.086
300
25
0.0601
0.0810
0.287
0.408
1.339
0.093
400
35
0.0470
0.0655
0.278
0.452
1.481
0.103
500
35
0.0366
0.0538
0.270
0.496
1.628
0.113
W / km
mF/ km
A/ km
W/m
A
A
146
160
3.57
2.29
175
195
5.0
2.29
205
232
7.15
2.29
245
285
10.0
2.29
295
345
13.5
2.29
330
395
17.1
2.29
370
450
21.4
3.58
415
500
26.4
3.58
482
590
34.3
3.58
540
660
42.9
3.58
610
750
57.2
5.07
675
860
71.5
5.07
KA
KA
mh/ km
TECHNICAL INFORMATION1. Weight and Dimension Data
kg/ km
SteelTape
Thickness
Approx.Overall
Diameter
Approx.Cable
Weight
Nominal Insulation Thickness
Nominal Sheath
Thickness
Nominal Cross
Section
mmmm mmmm2n x mm
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.8
0.8
0.8
50.2
53.3
56.6
60.1
64.5
67.2
71.3
75.4
81.1
87.3
93.5
99.9
3447
3946
4509
5460
6508
7449
8527
9901
12038
14953
17922
21393
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
3x25
3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x300
3x400
3x500
2.5
2.6
2.7
2.8
2.9
3.0
3.1
3.2
3.4
3.6
3.8
4.0
Medium Voltage Cables
Medium Voltage Cables 25
Three Core CableFor Installations outdoor in ground, in ducts and indoor on trays.
CU/XLPE/SWA/PVC, 8.7/15 KVIEC 60502-2Circular stranded Compacted copper (or Aluminum)Bonded semiconducting materialXLPE material Strippable semiconducting material (or Bonded)Copper tapePVC compound (or LSHF or PE)Galvanized Steel WiresPVC compound (or LSHF or PE)
Type :Standard :Conductor :Conductor Screen :Insulation :Insulation Screen :Metallic Screen :Bedding :Armoring :Jacketing :
TECHNICAL INFORMATION1. Weight and Dimension Data
2. Electrical Data
Cross section Area
Screen Area
oDC Resist at 20 CoAc Resist at 90 C
Inductance
Capacitance
Charging current
Dielectic losses
Current Ampacity
Cable in ground
Cable in free air
Short circuit current
Conductor S.C (1 Sec)
Screen S.C (1 Sec)
2mm
2mm
W / km
25
16
0.727
0.927
0.438
0.175
0.572
0.040
35
16
0.524
0.668
0.411
0.196
0.641
0.045
50
16
0.387
0.494
0.384
0.213
0.699
0.049
70
16
0.268
0.342
0.360
0.240
0.788
0.055
95
16
0.193
0.247
0.345
0.266
0.871
0.061
120
16
0.153
0.196
0.330
0.289
0.949
0.066
150
25
0.124
0.160
0.319
0.313
1.026
0.071
185
25
0.0991
0.1288
0.309
0.338
1.108
0.077
240
25
0.0754
0.0995
0.296
0.377
1.236
0.086
300
25
0.0601
0.0810
0.287
0.408
1.339
0.093
400
35
0.0470
0.0655
0.278
0.452
1.481
0.103
500
35
0.0366
0.0538
0.270
0.496
1.628
0.113
W / km
mF/ km
A/ km
W/m
A
A
160
172
5
2.29
175
199
5.0
2.29
205
235
7.15
2.29
245
285
10.0
2.29
295
345
13.5
2.29
333
395
17.1
2.29
370
445
21.4
3.58
415
505
26.47
3.58
470
570
34.4
3.58
525
635
42.9
3.58
640
735
57.2
5.07
690
820
71.5
5.07
KA
KA
mh/ km
2n x mm mm mmmm kg/ kmmm
Nominal Cross
Section
Nominal Insulation Thickness
SteelWire
Diameter
Approx.Overall
Diameter
Nominal Sheath
Thickness
Approx.Cable
Weight
3x25
3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x300
3x400
3x500
4942
5559
6169
7261
8425
9445
10638
13322
15731
18030
21248
24919
54.2
57.3
59.4
64.0
66.9
71.2
74.6
81.3
86.1
91.0
98.2
104.2
2.6
2.7
2.8
2.9
3.0
3.1
3.2
3.4
3.6
3.7
4.0
4.1
2.50
2.50
2.50
2.50
2.50
2.50
3.15
3.15
3.15
3.15
3.15
3.15
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
26
Single Core CableFor Installations outdoor in ground, in ducts and indoor on trays.
Type : CU/XLPE/PVC, 12/20 KVStandard : IEC 60502-2Conductor : Circular stranded Compacted copper (or Aluminum)Conductor Screen : Bonded semiconducting materialInsulation : XLPE material Insulation Screen : Strippable semiconducting material (or Bonded)Metallic Screen : Annealed Copper wires (or Copper Tape)Jacketing : PVC compound (or LSHF or PE)
TECHNICAL INFORMATION1. Weight and Dimension Data
2. Electrical Data
Cross section Area
Screen Area
oDC Resist at 20 CoAc Resist at 90 C
Inductance
Flat Formation
Trefoil Formation
Capacitance
Charging current
Dielectic losses
Current Ampacity
Cable in ground
Cable in free air
Short circuit current
Conductor S.C (1 Sec)
Screen S.C (1 Sec)
2mm
2mm
W / km
35
16
0.524
0.668
50 70 95 150 240 400 500 630120 185 300
W / km
mh/ km
mh/ km
0.521
0.472
0.491
0.443
0.466
0.417
mF/ km
A/ km
0.170
0.769
0.185
0.835
0.207
0.936
W/m 0.074 0.080 0.090
A
A
175
200
210
240
255
300
KA
KA
5.0
2.29
7.15
2.29
10.0
2.29
16
0.387
0.494
16
0.268
0.342
0.446
0.398
0.429
0.381
0.419
0.371
0.408
0.359
0.391
0.343
0.380
0.333
0.358
0.310
0.347
0.300
0.370
0.323
0.228
1.031
0.247
1.119
0.267
1.207
0.287
1.300
0.319
1.445
0.345
1.561
0.417
1.889
0.464
2.089
0.381
1.723
0.099 0.107 0.116 0.125 0.139 0.150 0.181 0.2010.165
305
360
345
415
385
475
430
540
500
640
560
730
710
960
795
1105
630
840
13.5
2.29
17.1
2.29
21.4
3.58
26.4
3.58
34.4
3.58
42.9
3.58
71.5
5.07
90.0
5.07
57.2
5.07
16
0.193
0.247
16
0.153
0.196
25
0.124
0.160
25
0.0991
0.1286
25
0.0754
0.0990
25
0.0601
0.0806
35
0.366
0.0530
35
0.0283
0.0440
35
0.0470
0.0641
2n x mm
Nominal Cross
Section
mm
Nominal Insulation Thickness
mm mm
Nominal Sheath
Thickness
Approx.Overall
Diameter
Approx.Cable
Weight
kg/km
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500
1x630
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
1.8
1.8
1.9
1.9
2.0
2.0
2.1
2.2
2.2
2.3
2.4
2.5
27.5
28.6
30.6
32.8
34.5
36.6
37.6
41.0
42.9
45.6
48.4
53.5
1024
1171
1424
1710
1984
2368
2721
3370
3981
4932
5911
7504
Medium Voltage Cables
Medium Voltage Cables 27
Three Core CableFor Installations outdoor in ground, in ducts and indoor on trays.
CU/XLPE/PVC, 12/20 KVIEC 60502-2Circular stranded Compacted copper (or Aluminum)Bonded semiconducting materialXLPE material Strippable semiconducting material (or Bonded)Copper tape (or Copper Wire)PVC compound (or LSHF or PE)
Type :Standard :Conductor :Conductor Screen :Insulation :Insulation Screen :Metallic Screen :Jacketing :
TECHNICAL INFORMATION
2. Electrical Data
Cross section Area
Screen Area
oDC Resist at 20 CoAc Resist at 90 C
Inductance
Capacitance
Charging current
Dielectic losses
Current Ampacity
Cable in ground
Cable in free air
Short circuit current
Conductor S.C (1 Sec)
Screen S.C (1 Sec)
2mm
2mm
W / km
35
16
0.524
0.668
0.429
0.170
0.769
0.074
50
16
0.387
0.402
0.410
0.185
0.835
0.080
70
16
0.268
0.342
0.378
0.207
0.936
0.090
95
16
0.193
0.247
0.361
0.228
1.031
0.099
120
16
0.153
0.196
0.344
0.247
1.119
0.107
150
25
0.124
0.160
0.333
0.267
1.207
0.116
185
25
0.0991
0.1286
0.323
0.287
1.300
0.125
240
25
0.0754
0.0993
0.308
0.319
1.445
0.139
300
25
0.0601
0.0806
0.299
0.345
1.561
0.150
400
35
0.0470
0.0652
0.289
0.381
1.723
0.165
W / km
mF/ km
A/ km
W/m
A
A
175
195
5.0
2.29
205
240
7.15
2.29
250
285
10.0
2.29
300
350
13.5
2.29
340
395
17.1
2.29
380
450
21.4
3.58
425
510
26.4
3.58
490
600
34.4
3.58
555
680
42.9
3.58
625
775
57.2
5.07
KA
KA
mh/ km
1. Weight and Dimension Data Nominal Sheath
Thickness
Approx.Cable
Weight
Approx.Overall
Diameter
Nominal Cross
Section
Nominal Insulation Thickness
n x mm2 mm kg/kmmm mm
3539
4075
4908
5954
6858
7986
9229
11303
13345
16276
2.6
2.7
2.8
3.0
3.1
3.2
3.3
3.5
3.6
3.9
56.6
59.5
63.1
66.5
70.3
74.4
76.9
82.9
88.1
95.0
3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x300
3x400
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
28
Three Core CableFor Installations outdoor in ground, in ducts and indoor on trays.
CU/XLPE/STA/PVC, 12/20 KVIEC 60502-2Circular stranded Compacted copper (or Aluminum)Bonded semiconducting materialXLPE material Strippable semiconducting material (or Bonded)Copper tapePVC compound (or LSHF or PE)Galvanized Steel TapePVC compound (or LSHF or PE)
Type :Standard :Conductor :Conductor Screen :Insulation :Insulation Screen :Metallic Screen :Bedding :Armoring :Jacketing :
TECHNICAL INFORMATION1. Weight and Dimension Data
Approx.Cable
Weight
kg/ km
Nominal Insulation Thickness
mm
Approx.Overall
Diameter
mm
Nominal Cross
Section 2n x mm
Nominal Sheath
Thickness
mm
SteelTape
Thickness
mm
4454
5032
5933
7011
7972
9204
10507
13463
15632
18797
58.0
61.5
65.4
68.0
72.4
76.5
80.0
87.1
91.5
98.6
2.7
2.8
2.9
3.0
3.1
3.3
3.4
3.6
3.7
4.0
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x300
3x400
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
2. Electrical Data
Cross section Area
Screen Area
oDC Resist at 20 CoAc Resist at 90 C
Inductance
Capacitance
Charging current
Dielectic losses
Current Ampacity
Cable in ground
Cable in free air
Short circuit current
Conductor S.C (1 Sec)
Screen S.C (1 Sec)
2mm
2mm
W / km
35
16
0.524
0.668
0.429
0.170
0.769
0.074
50
16
0.387
0.494
0.402
0.185
0.835
0.080
70
16
0.268
0.342
0.378
0.207
0.936
0.090
95
16
0.193
0.247
0.361
0.228
1.031
0.099
120
16
0.153
0.196
0.350
0.247
1.119
0.107
150
25
0.124
0.160
0.333
0.267
1.207
0.116
185
25
0.0991
0.1286
0.323
0.287
1.300
0.125
240
25
0.0754
0.0992
0.308
0.319
1.445
0.139
300
25
0.0601
0.0806
0.300
0.345
1.561
0.150
400
35
0.0470
0.0652
0.289
0.381
1.723
0.165
W / km
mF/ km
A/ km
W/m
A
A
175
195
5.0
2.29
205
240
7.15
2.29
245
285
10.0
2.29
295
350
13.5
2.29
330
395
17.1
2.29
370
450
21.4
3.58
415
500
26.4
3.58
485
590
34.4
3.58
540
685
42.9
3.58
610
750
57.2
5.07
KA
KA
mh/ km
Medium Voltage Cables
Medium Voltage Cables 29
Three Core CableFor Installations outdoor in ground, in ducts and indoor on trays.
CU/XLPE/SWA/PVC, 12/20 KVIEC 60502-2Circular stranded Compacted copper (or Aluminum)Bonded semiconducting materialXLPE material Strippable semiconducting material (or Bonded)Copper tape (or Copper Wires)PVC compound (or LSHF or PE)Galvanized Steel WiresPVC compound (or LSHF or PE)
Type :Standard :Conductor :Conductor Screen :Insulation :Insulation Screen :Metallic Screen :Bedding :Armoring :Jacketing :
TECHNICAL INFORMATION1. Weight and Dimension Data
Approx.Cable
Weight
kg/ km
Nominal Insulation Thickness
mm
Approx.Overall
Diameter
mm
Nominal Cross
Section
2n x mm
Nominal Sheath
Thickness
mm
SteelWire
Diameter
mm
6199
6862
7873
9069
10146
12635
14146
16545
18864
22248
62.2
64.7
68.6
72.3
75.0
81.2
85.0
91.6
96.1
102.1
2.8
3.0
3.0
3.1
3.3
3.4
3.6
3.7
3.8
4.1
2.50
2.50
2.50
2.50
2.50
3.15
3.15
3.15
3.15
3.15
3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x300
3x400
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
2. Electrical Data
Cross section Area
Screen Area
oDC Resist at 20 CoAc Resist at 90 C
Inductance
Capacitance
Charging current
Dielectic losses
Current Ampacity
Cable in ground
Cable in free air
Short circuit current
Conductor S.C (1 Sec)
Screen S.C (1 Sec)
2mm
2mm
W / km
35
16
0.524
0.668
0.430
0.170
0.769
0.074
50
16
0.387
0.494
0.402
0.185
0.835
0.080
70
16
0.268
0.342
0.378
0.207
0.936
0.090
95
16
0.193
0.247
0.361
0.228
1.031
0.099
120
16
0.153
0.196
0.350
0.247
1.119
0.107
150
25
0.124
0.159
0.333
0.267
1.207
0.116
185
25
0.0991
0.1286
0.323
0.287
1.300
0.125
240
25
0.0754
0.0992
0.308
0.319
1.445
0.139
300
25
0.0601
0.0806
0.300
0.345
1.561
0.150
400
35
0.0470
0.0652
0.289
0.381
1.723
0.165
W / km
mF/ km
A/ km
W/m
A
A
175
200
5.0
2.29
205
235
7.15
2.29
245
290
10.0
2.29
295
350
13.5
2.29
330
400
17.1
2.29
370
450
21.4
3.58
410
500
26.4
3.58
470
590
34.4
3.58
520
660
42.9
3.58
585
725
57.2
5.07
KA
KA
mh/ km
30
Single Core CableFor Installations outdoor in ground, in ducts and indoor on trays.
Type : CU/XLPE/PVC, 18/30 KVStandard : IEC 60502-2Conductor : Circular stranded Compacted copper (or Aluminum)Conductor Screen : Bonded semiconducting materialInsulation : XLPE material Insulation Screen : Strippable semiconducting material (or Bonded)Metallic Screen : Copper wires (or Copper Tape)Bedding : PVC compound (or LSHF or PE)Jacketing : PVC compound (or LSHF or PE)
TECHNICAL INFORMATION1. Weight and Dimension Data
mm
32.1
34.4
35.2
37.1
39.4
41.6
43.2
45.5
47.2
51.6
54.5
59.3
mm
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
Approx.Overall
Diameter
Nominal Insulation Thickness
mm2n x mm kg/km
Nominal Sheath
Thickness
Nominal Cross
Section
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500
1x630
Approx.Cable
Weight
1.9
2.0
2.0
2.1
2.1
2.2
2.2
2.3
2.4
2.5
2.6
2.7
1253
1431
1680
2000
2264
2683
3066
3707
4357
5324
6345
7963
2. Electrical Data
Cross section Area
Screen Area
oDC Resist at 20 CoAc Resist at 90 C
Inductance
Flat Formation
Trefoil Formation
Capacitance
Charging current
Dielectic losses
Current Ampacity
Cable in ground
Cable in free air
Short circuit current
Conductor S.C (1 Sec)
Screen S.C (1 Sec)
2mm
2mm
W / km
35
16
0.524
0.668
50 70 95 150 240 400 500 630120 185 300
W / km
mh/ km
mh/ km
0.555
0.509
0.525
0.477
0.497
0.450
mF/ km
A/ km
0.133
0.903
0.143
0.974
0.159
1.081
W/m 0.130 0.140 0.156
A
A
176
205
210
243
257
305
KA
KA
5.0
2.29
7.15
2.29
10.0
2.29
16
0.387
0.494
16
0.268
0.342
0.477
0.429
0.458
0.411
0.447
0.399
0.433
0.386
0.414
0.368
0.404
0.356
0.381
0.332
0.366
0.320
0.393
0.343
0.174
1.181
0.192
1.274
0.201
1.366
0.216
1.464
0.238
1.161
0.256
1.737
0.306
2.600
0.340
2.300
0.281
1.906
0.170 0.183 0.197 0.221 0.233 0.250 0.300 0.3300.270
305
368
346
419
387
479
432
545
500
645
563
732
712
965
795
1105
630
845
13.5
2.29
17.1
2.29
21.4
3.58
26.4
3.58
34.4
3.58
42.9
3.58
71.5
5.07
90.0
5.07
57.2
5.07
16
0.193
0.247
16
0.153
0.196
25
0.124
0.160
25
0.0991
0.1286
25
0.0754
0.0990
25
0.0601
0.0806
35
0.0366
0.0530
35
0.0283
0.0440
35
0.0470
0.0641
Medium Voltage Cables
Medium Voltage Cables 31
Three Core CableFor Installations outdoor in ground, in ducts and indoor on trays.
Type : CU/XLPE/PVC, 18/30 KVStandard : IEC 60502-2Conductor : Circular stranded Compacted copper (or Aluminum)Conductor Screen : Bonded semiconducting materialInsulation : XLPE material Insulation Screen : Strippable semiconducting material (or Bonded)Metallic Screen : Copper tape (or Copper Wire)Bedding : PVC compound (or LSHF or PE)Jacketing : PVC compound (or LSHF or PE)
TECHNICAL INFORMATION1. Weight and Dimension Data
3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x300
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
3.0
3.1
3.2
3.3
3.5
3.6
3.7
3.8
4.0
68.4
69.9
75.1
77.9
82.5
85.3
89.4
95.1
100.2
4620
5206
6175
7251
8252
9360
10663
12781
15046
Approx.Overall
Diameter
Nominal Insulation Thickness
Nominal Sheath
Thickness
Nominal Cross
Section
Approx.Cable
Weight
mmmm mm2n x mm kg/km
2. Electrical Data
177
200
5.0
2.29
KA
KA
Short circuit current
Conductor S.C (1 Sec)
Screen S.C (1 Sec)
Cross section Area
Screen Area
oDC Resist at 20 CoAc Resist at 90 C
Inductance
Capacitance
Charging current
Dielectic losses
Current Ampacity
Cable in ground
Cable in free air
2mm
2mm
W / km
35
16
0.524
0.668
0.470
0.133
0.903
0.130
50
16
0.387
0.494
0.441
0.143
0.974
0.140
70
16
0.268
0.342
0.423
0.159
1.081
0.156
95
16
0.193
0.247
0.404
0.174
1.181
0.170
120
16
0.153
0.196
0.389
0.188
1.274
0.183
150
25
0.124
0.159
0.376
0.201
1.366
0.197
185
25
0.0991
0.1286
0.364
0.216
1.464
0.211
240
25
0.0754
0.0993
0.348
0.238
1.616
0.233
300
25
0.0601
0.0806
0.338
0.256
1.737
0.250
W / km
mF/ km
A/ km
W/m
A
A
205
240
7.15
2.29
252
290
10.0
2.29
302
360
13.5
2.29
340
405
17.1
2.29
380
455
21.4
3.58
429
520
26.4
3.58
494
610
34.4
3.58
555
690
42.9
3.58
mh/ km
32
Three Core CableFor Installations outdoor in ground, in ducts and indoor on trays.
CU/XLPE/ STA/PVC, 18/30 KVIEC 60502-2Circular stranded Compacted copper (or Aluminum)Bonded semiconducting materialXLPE material Strippable semiconducting material (or Bonded)Copper tape (or Copper Wire)PVC compound (or LSHF or PE)Galvanized steel tapes PVC compound (or LSHF or PE)
Type :Standard :Conductor :Conductor Screen :Insulation :Insulation Screen :Metallic Screen :Bedding :Armoring :Jacketing :
Approx.Cable
Weight
kg/ km
Nominal Insulation Thickness
mm
Approx.Overall
Diameter
mm
Nominal Cross
Section
2n x mm
Nominal Sheath
Thickness
mm
SteelTape
Thickness
mm
5786
6403
7456
8595
10419
11625
13019
15343
17692
71.0
73.7
77.9
80.6
85.5
89.8
92.6
98.5
103.3
3.1
3.2
3.3
3.4
3.6
3.7
3.8
4.0
4.1
0.5
0.5
0.5
0.5
0.8
0.8
0.8
0.8
0.8
3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x300
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
TECHNICAL INFORMATION1. Weight and Dimension Data
2. Electrical Data
Cross section Area
Screen Area
oDC Resist at 20 CoAc Resist at 90 C
Inductance
Capacitance
Charging current
Dielectic losses
Current Ampacity
Cable in ground
Cable in free air
Short circuit current
Conductor S.C (1 Sec)
Screen S.C (1 Sec)
2mm
2mm
W / km
35
16
0.524
0.668
0.470
0.133
0.903
0.130
50
16
0.387
0.494
0.449
0.143
0.974
0.140
70
16
0.268
0.342
0.423
0.159
1.081
0.156
95
16
0.193
0.247
0.404
0.174
1.181
0.170
120
16
0.153
0.196
0.389
0.188
1.274
0.183
150
25
0.124
0.159
0.376
0.201
1.366
0.197
185
25
0.0991
0.1286
0.364
0.216
1.464
0.211
240
25
0.0754
0.0993
0.348
0.238
1.616
0.233
300
25
0.0601
0.0806
0.338
0.256
1.737
0.250
W / km
mF/ km
A/ km
W/m
A
A
174
199
5.0
2.29
204
235
7.15
2.29
245
287
10.0
2.29
295
350
13.5
2.29
335
400
17.1
2.29
370
450
21.4
3.58
420
505
26.4
3.58
483
590
34.4
3.58
540
655
42.9
3.58
KA
KA
mh/ km
Medium Voltage Cables
Medium Voltage Cables 33
Three Core CableFor Installations outdoor in ground, in ducts and indoor on trays.
CU/XLPE/SWA/PVC, 18/30 KVIEC 60502-2Circular stranded Compacted copper (or Aluminum)Bonded semiconducting materialXLPE material Strippable semiconducting material (or Bonded)Copper tape (or Copper Wire)PVC compound (or LSHF or PE)
: Galvanized Steel Wires PVC compound (or LSHF or PE)
Type :Standard :Conductor :Conductor Screen :Insulation :Insulation Screen :Metallic Screen :Bedding :ArmoringJacketing :
TECHNICAL INFORMATION1. Weight and Dimension Data
2. Electrical Data
Cross section Area
Screen Area
oDC Resist at 20 CoAc Resist at 90
Inductance
Capacitance
Charging current
Dielectic losses
Current Ampacity
Cable in ground
Cable in free air
Short circuit current
Conductor S.C (1 Sec)
Screen S.C (1 Sec)
2mm
2mm
W / km
35
16
0.524
0.668
0.470
0.133
0.903
0.130
50
16
0.387
0.494
0.449
0.143
0.974
0.140
70
16
0.268
0.342
0.423
0.159
1.081
0.156
95
16
0.193
0.247
0.404
0.174
1.181
0.170
120
16
0.153
0.196
0.389
0.188
1.274
0.183
150
25
0.124
0.159
0.376
0.201
1.366
0.197
185
25
0.0991
0.1286
0.364
0.216
1.464
0.211
240
25
0.0754
0.0993
0.348
0.238
1.616
0.233
300
25
0.0601
0.0806
0.338
0.256
1.737
0.250
W / km
mF/ km
A/ km
W/m
A
A
174
200
5.0
2.29
204
235
7.15
2.29
245
290
10.0
2.29
295
350
13.5
2.29
330
400
17.1
2.29
370
488
21.4
3.58
420
500
26.4
3.58
470
585
34.4
3.58
520
655
42.9
3.58
KA
KA
mh/ km
Approx.Cable
Weight
kg/ km
Nominal Insulation Thickness
mm
Approx.Overall
Diameter
mm
Nominal Cross
Section
2n x mm
Nominal Sheath
Thickness
mm
SteelWire
Diameter
mm
7862
9721
10909
12283
13390
14719
16238
18792
21303
73.5
78.2
82.4
85.9
90.2
93.3
97.2
102.0
107.1
3.2
3.4
3.5
3.6
3.7
3.8
3.9
4.1
4.2
2.50
3.15
3.15
3.15
3.15
3.15
3.15
3.15
3.15
3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x300
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
34
The performance of the cable at low temperatures is determined by the properties of the sheath material, the cold flexibility Oof which is adequate down to - 15 C. This does not apply to temperatures during installation of the cables.
Working temperatures••
• •
OConductor temperature for continuous operation 90 C. OConductor temperature during emergency loads of 130 C (up to 33kV).
Maximum duration of 8 hours continuously, with a maximum total of 125 hours/annum. OConductor temperature after short-circuit 250 C.
OScreen and armouring temperature after short-circuit 200 C (PVC sheath assumed).
General Characteristics Medium Voltage Electric Cable - 6,6kV to 33kV to SANS 1339
OTensile strength at 20 C2MPa (N/mm )
OElongation at break at 20 C (%)O OVolume resistivity at 20 C - 90 C Ohm/cm
ODielectric power factor at 20 C ODielectric power factor at 95 C
Mean 15
Mean 3501610
-410.10-420.10
12,5
2001410
-430.10-460.10
D = Overall cable diameter
(mm)
Mechanical and electrical properties of XLPE measured on the cable
Result Requirement
Bending radii Single-core 3-core
Recommended
Minium
At sealing ends
17 x D
15 x D
12 x D
15 x D
12 x D
10 x D
Current rating Explanation of the tables.
Remarks
Conditions, under which the values mentioned in the tables apply, are : One three-phase circuit, continuously fully loaded. Single-core cables in trefoil formation touching and in flat formation respectively with axial separation of 150 mm and regular transposition.
OConductor temperature 90° C Ground temperature 25 C.Depth of laying 800 mm Soil thermal resistivity 1.2 K.m/W.Ambient temperature 30°C in free air (Shaded) Solidly bonded at both ends.Absence of Other heat sources.
OIn certain types of soil, a conductor operating temperature of 90 C for cables laid direct or in pipes may result in drying of the soil where a critical temperature of 55 °C is exceeded. Various alternatives have been recommended, eg:a) Restricting the sheath temperatures to 55 °C (by reducing conductor temperature);b) Rating the cable for fully dried out soil (thermal resistivity 3 K.m./W) (both methods a & b causes substaintial reductions in current ratings);c) Using a back-fill of stable thermal resistivity not exceeding 1.5 K.m/W and rated accordingly for a conductor temperature of 90 °C.d) Using the CIGRE method (Electra No.104, January 1986, Pages 11-22) of calculating a revised current rating assuming a partially dried out soil model. Tirupati Plastomatics Power Cables Technical Division will be plased to advise on ratings and backfills necessary for your requirements. Tirupati Plastomatics Cables Technical Division will be pleased to advise on ratings on ratings and backfills necessary for your requirements.
Note : The nominal data supplied in this publication has been compiled with every attempt at accuracy with the sole purpose of providing for the reader a convenient and practical directive without commitment. All dimensions are in line with SANS 1339, unless otherwise stated.
••
• •• •• ••
Medium Voltage Cables
Medium Voltage Cables 35
Manufacturing RangeMedium Voltage Electric Cable - 6,6kV to 33kV to SANS 1339
Standard drum lengths :
300 metres - longer lengths can be manufactured if required.
* Note : The maximum and minimum conductor size above are our standard.
Please enquire if smaller or larger than the standard size is required.
Cables and dimensions are in accordance with SANS 1339, except for the 87/15kV cables.
No data is given in this brochure for cables above 33kV.
Type Specification No. of Cores
Voltage (kV) Conductor 2Sizes (mm )
‘Tirupati’Type A
‘Tirupati’Type A
‘Tirupati’Type B
‘Tirupati’Type B
‘Tirupati’special
type
XLPE insulated, individually copper tape screened, PVC bedded, steel wire
armoured, PVC sheathed
XLPE insulated, copper tape screened, PVC bedded,
aluminium wire armoured, PVC sheathed
XLPE insulated, individuallycopper tapes screened,
unarmoured, PVC sheathed
XLPE insulated, copper (single)taped screened,
unarmoured, PVC sheathed
XLPE insulated, individually copper tape screened,
equalising cu tape, with or without steel wire armour,
PVC sheathed
3
1
3
1
3
3,8/6,6 - 6,35/11
8,7/15 - 12,7/22
19/33
3,8/6,6 - 12,7/22
19/33
3,8/6,6 - 6,35/11
8,7/15 - 12,7/22
19/33
3,8/6,6 - 12,7/22
19/33
3,8/6,6 - 6,35/11
8,7/15 - 12,7/22
19/33
cu: 25-400alu: 50-400
cu: 25-240alu: 50-240
cu: 50-240alu: 50-240
cu: 25-630alu: 50-630
cu: 50-500alu: 50-500
cu: 25-400alu: 50-400
cu: 25-240alu: 50-240
cu: 25-240alu: 50-240
cu: 25-630alu: 50-630
cu: 50-500alu: 50-500
cu: 25-400alu: 50-400
cu: 25-240alu: 50-240
cu: 50-240
36
Type of Cables Medium Voltage Electric Cable - 6,6kV to 33kV
Tirupati Plastomatics TYPE A
Cables are designed to carry high earth fault currents comparable with system symmetrical fault currents.
3 Core Type A cables are supplied with galvanised steel wire armouring.
Single-core cables are normally supplied arm oured with a single layer of aluminium wires.
TIRUPATI TYPE A TIRUPATI TYPE A
TIRUPATI TYPE A CROSS SECTION
(Three Core)
TIRUPATICROSS SECTION
(Single Core)
TYPE A
TIRUPATI
Cables are designed to carry limited earth fault currents of 1000 A for one second.
Higher currents may be carried where the total earth fault clearance time is less than one second, provided that the product of the square of the current in amperes and the
5clearance time in seconds does not exceed 10 .
PLASTOMATICS TYPE B
TIRUPATI TYPE B TIRUPATI TYPE B
TIRUPATICROSS SECTION
(Three Core)
TYPE B TIRUPATICROSS SECTION
(Single Core)
TYPE B
Medium Voltage Cables
Medium Voltage Cables 37
Construction Medium voltage Electric Cable - 6,6kV to 33kV
Construction of the cables
1 Conductor - aluminium or copper
2 Conductor screen - extruded semi conductive layer integral with:
3 Insulation - XLPE
4 Core screen - extruded free strippable semi-conductive layer
5 Semi-conductive numbered tape * *
6 Metalic earth screen - copper tape (s)
7 Fillers - pre-formed plastic material *
8 Binder tape
9 Inner sheath (bedding)
10 Armouring (Steel wire or Aluminium wire)
11 Outer sheath
* Other materials may be used when required. ** Core identification : alternative printed numbers on each core - 1,2 and 3 or Colour Strips.
38
Due to the fact that Tirupati Plastomatics XLPE insulation is resistant to high temperatures, it is also obvious that higher temperatures are permissible in the cable.
OFor XLPE, continuous conductor temperatures up to 90 C are permissible, whilst for some hours a temperature of 130° C is permissible. In case of short-circuit the conductor can withstand considerably higher temperature
O(up to 250 C).
This important specific characteristic, n contrast with those generally applicable to plastics, give XLPE insulated cables the following advantages:
• suitable for a sustained conductor temperature of 90° C as a result of which a high current carrying capacity is obtained.
• suitable up to 125 hours/annum, (no event being longer than 8 hours continuously) at conductor temperature of 130 °C so that emergency loads can be tolerated
• no drainage problems
• clean handling
• relatively low cost per installed kVA
In addition to the normal application as underground cables, the following specific possibilities can be indicated:
• installation in buildings (vertical mounting)
• installation in outes with great difference in height
• installation in substations and power stations
This high current-carrying capacity can profitably be used in those cases where higher temperatures do not occur for to long or too often, viz. as a result of daily or yearly winter peaks. Normally improved thermal dissipation during the night or colder weather improves the thermal stability of the installation.
Notwithstanding these claims for higher sustained current ratings, where higher than normal ambient temperatures are obtained, (as in enclosed cable ducts or in ground which may dry out progressively under a sustained buried cable load) care should be taken when selecting the conductor material and area. Refer to remarks (a) and (b) under General Characteristics.
In the current rating tables, the values in brackets next to the continuous current values, indicates the outer Osheath temperature in C, expected when the cable is fully loaded under the stated conditions of installation.
Properties and applications Medium voltage Electric Cable - 6,6kV to 33kV
Medium Voltage Cables
Medium Voltage Cables 39
TIR
UP
AT
I Ty
pe
A -
Th
ree
Co
re
41
.5
44
.0
48
.0
51
.5
55
.5
59
.3
62
.5
68
.0
74
.5
82
.0
47
.0
49
.5
52
.0
55
.5
60
.0
64
.0
68
.5
72
.5
78
.5
85
.0
37
30
42
30
53
20
63
95
75
90
68
50
99
00
12
08
0
14
24
0
17
32
0
46
55
52
15
58
95
69
95
81
70
93
70
112
40
12
77
5
14
95
5
17
86
5
44
30
50
45
57
55
63
45
69
95
85
10
98
70
114
70
50
15
56
35
63
40
70
45
83
50
92
40
10
58
0
12
07
0
33
.3
35
.6
38
.2
41
.8
45
.7
49
.0
52
.1
56
.0
62
.2
69
.2
37
.4
39
.6
42
.3
45
.8
49
.8
53
.1
56
.2
60
.0
65
.9
72
.0
40 Medium Voltage Cables
25
35
50
70
95
12
0
15
0
18
5
24
0
5.9
7.0
8.2
9.8
11
.5
13
.0
14
.4
16
.1
18
.7
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
42
.2
44
.5
47
.1
50
.9
54
.9
57
.9
61
.2
64
.1
70
.9
2.5
0
2.5
0
2.5
0
2.5
0
3.1
5
3.1
5
3.1
5
3.1
5
3.5
5
52
.5
55
.3
57
.5
61
.5
67
.5
70
.0
74
.0
78
.0
87
.0
5 3
80
5 9
15
6 6
30
7 8
30
9 7
25
10
83
5
12
18
0
13
80
0
16
76
0
5 7
45
6 4
65
7 8
65
8 5
30
9 2
95
10
19
5
12
35
0
*Ra
ted
Vo
lta
ge
8.7
/15
kV
25
35
50
70
95
12
0
15
0
18
5
24
0
50
70
95
12
0
15
0
18
5
24
0
5.9
7.0
8.2
9.8
11
.5
13
.0
14
.4
16
.1
18
.7
8.2
9.8
11
.5
13
.0
14
.4
16
.1
18
.7
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
8.0
8.0
8.0
8.0
8.0
8.0
8.0
46
.7
49
.0
51
.5
55
.2
59
.2
62
.2
66
.5
69
.4
75
.2
62
.8
66
.4
70
.3
73
.6
76
.7
80
.6
86
.6
2.5
0
2.5
0
2.5
0
2.5
0
3.1
5
3.1
5
3.1
5
3.1
5
3.5
5
3.1
5
3.1
5
3.5
5
3.5
5
3.5
5
3.5
5
3.5
5
57
.5
59
.3
62
.0
67
.2
72
.0
75
.8
78
.3
83
.0
91
.5
76
.0
79
.0
86
.3
89
.8
92
.8
97
.1
10
3.3
6 0
60
6 6
00
7 2
50
9 1
55
10
44
5
11
65
0
13
00
5
14
64
5
17
54
5
9 9
80
11
28
0
13
28
0
14
65
5
15
94
5
17
62
0
20
06
0
6 3
90
7 8
15
8 6
25
9 3
40
10
11
5
11
06
0
13
15
0
0.7
27
0.5
24
0.3
87
0.2
68
0.1
93
0.1
53
0.1
24
0.0
99
0.0
75
0.6
41
0.4
43
0.3
20
0.2
53
0.2
06
0.1
64
0.1
25
0.9
27
0.6
68
0.4
94
0.3
42
0.2
47
0.1
96
0.1
59
0.1
28
0.0
98
0.8
22
0.5
68
0.4
10
0.3
25
0.2
65
0.2
11
0.1
61
0.1
33
0.1
26
0.1
13
0.1
08
0.1
07
0.1
03
0.1
00
0.0
97
0.0
93
16
4
17
9
19
5
21
9
24
4
26
4
28
4
30
8
34
5
14
0
17
0
20
0
24
0
29
0
32
5
36
0
41
0
47
0
15
5
19
0
22
5
25
5
28
5
32
0
37
0
11
5
13
5
16
0
19
5
23
0
26
0
29
0
32
5
37
0
12
5
15
0
18
0
20
5
23
0
25
5
29
5
15
5
19
0
22
5
28
0
33
5
38
5
44
0
49
0
58
0
17
5
22
0
26
0
30
0
34
0
39
0
46
0
0.7
27
0.5
24
0.3
87
0.2
68
0.1
93
0.1
53
0.1
24
0.0
99
0.0
75
0.3
87
0.2
68
0.1
93
0.1
53
0.1
24
0.0
99
0.0
75
0.6
41
0.4
43
0.3
20
0.2
53
0.2
06
0.1
64
0.1
25
0.6
41
0.4
43
0.3
20
0.2
53
0.2
06
0.1
64
0.1
25
0.9
27
0.6
68
0.4
94
0.3
42
0.2
47
0.1
96
0.1
59
0.1
28
0.0
98
0.4
94
0.3
42
0.2
47
0.1
96
0.1
59
0.1
28
0.0
98
0.8
22
0.5
68
0.4
10
0.3
25
0.2
65
0.2
11
0.1
61
0.8
22
0.5
68
0.4
10
0.3
25
0.2
65
0.2
11
0.1
61
0.1
40
0.1
32
0.1
26
0.1
19
0.1
12
0.1
08
0.1
04
0.1
01
0.0
97
0.1
39
0.1
31
0.1
23
0.1
19
0.1
15
0.1
11
0.1
06
14
3
15
6
17
0
18
9
21
0
22
7
24
3
26
3
29
3
13
3
14
7
16
2
17
3
18
5
19
9
22
0
14
5
17
0
20
0
24
5
29
0
32
5
36
0
41
0
47
0
20
0
24
5
29
0
32
5
36
0
41
0
46
0
15
5
19
0
22
5
25
5
28
5
32
0
37
0
15
5
19
0
22
5
25
5
28
5
32
0
37
0
11
5
13
5
16
0
19
5
23
0
26
0
29
0
32
5
37
0
16
0
19
5
23
0
26
0
29
0
32
5
37
0
16
0
19
0
23
0
28
0
34
0
38
5
43
5
50
0
58
0
18
0
22
0
26
5
30
5
34
0
39
5
46
0
18
0
22
0
27
0
31
0
35
0
40
0
47
0
*Ra
ted
Vo
lta
ge
12
.7/2
2 K
V
*Ra
ted
Vo
lta
ge
19
/33
kV
9 1
45
9 9
10
11
37
5
12
27
5
13
02
0
14
06
0
15
70
0
12
5
15
0
18
0
20
5
23
0
25
5
29
5
Medium Voltage Cables 41
TIR
UP
AT
I Ty
pe
A -
Sin
gle
Co
re
23
.5
24
.0
25
.5
27
.0
28
.5
30
.5
32
.0
33
.0
38
.0
41
.5
45
.0
49
.5
94
3
10
75
12
40
15
35
18
55
21
50
25
00
30
25
36
05
44
30
54
80
67
75
95
5
10
90
12
55
13
90
15
55
18
85
21
75
25
35
30
85
37
35
24
.5
26
.0
27
.0
29
.5
30
.5
32
.4
35
.5
37
.0
39
.5
42
.2
46
.0
50
.0
10
35
117
5
13
45
16
75
19
80
22
85
27
65
32
00
37
55
45
45
55
95
68
20
10
60
12
15
13
75
15
30
18
15
20
15
23
20
26
40
31
85
37
95
16
.5
17
.6
18
.7
20
.3
22
.1
23
.5
24
.9
26
.7
29
.5
32
.6
36
.5
39
.3
18
.1
19
.4
20
.5
22
.4
23
.9
25
.3
26
.7
28
.5
31
.1
33
.8
37
.3
39
.7
42 Medium Voltage Cables
27.7
28.8
29.9
31.6
34.6
36.2
37.4
39.3
42.1
45.1
50.1
51.1
1 1
90
1 3
35
1 5
05
1 8
10
2 2
55
2 5
80
2 9
35
3 3
70
3 9
65
4 7
65
6 0
05
7 0
05
1215
1360
1655
1825
1990
2200
2535
2805
3610
3980
20.8
21.9
23.0
24.6
26.4
27.8
29.0
30.7
33.3
36.3
40.0
40.8
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
1.6
1.6
1.6
2.0
2.0
2.0
2.0
2.0
2.0
2.5
2.5
2.5
22.8
23.9
25.0
26.6
28.4
29.8
31.2
33.0
35.3
38.5
42.0
43.0
29.9
31.0
32.1
34.9
36.8
38.0
39.9
41.6
44.1
48.5
52.1
53.3
1 3
40
1 4
80
1 6
70
2 0
85
2 4
30
2 7
65
3 1
20
3 5
50
4 1
35
5 1
75
6 1
95
7 2
45
2 1
85
2 5
15
2 8
95
3 2
15
3 8
05
4 2
55
4 8
90
5 7
75
6 8
45
7 9
95
0.7
27
0.5
24
0.3
87
0.2
68
0.1
93
0.1
53
0.1
24
0.0
99
0.0
75
0.0
60
0.0
47
0.0
37
0.3
87
0.2
68
0.1
93
0.1
53
0.1
24
0.0
99
0.0
75
0.0
60
0.0
47
0.0
37
0.6
41
0.4
43
0.3
20
0.2
53
0.2
06
0.1
64
0.1
25
0.1
00
0.0
78
0.0
61
0.4
94
0.3
42
0.2
47
0.1
96
0.1
59
0.1
28
0.9
8
0.7
9
0.0
63
0.0
51
0.8
22
0.5
68
0.4
10
0.3
25
0.2
65
0.2
11
0.1
61
0.1
30
0.1
02
0.0
80
0.1
49
0.1
41
0.1
33
0.1
28
0.1
24
0.1
20
0.1
15
0.1
11
0.1
07
0.1
04
0.2
70
0.2
59
0.2
49
0.2
42
0.2
36
0.2
30
0.2
22
0.2
14
0.2
07
0.2
02
133
147
162
173
185
199
220
243
266
283
0.9
27
0.6
68
0.4
94
0.3
42
0.2
47
0.1
96
0.1
59
0.1
28
0.0
98
0.0
79
0.0
63
0.0
51
0.1
53
0.1
45
0.1
38
0.1
30
0.1
22
0.1
19
0.1
15
0.1
11
0.1
06
0.1
02
0.0
99
0.0
97
0.2
87
0.2
78
0.2
68
0.2
58
0.2
47
0.2
40
0.2
34
0.2
28
0.2
20
0.2
12
0.2
05
0.2
01
143
156
17
189
210
227
243
263
293
325
358
383
145(7
0)
170(7
1)
200(7
2)
245(7
3)
290(7
4)
325(7
5)
365(7
6)
410(7
7)
460(7
7)
510(7
8)
550(7
8)
600(7
9)
200(7
1)
245(7
2)
290(7
3)
325(7
3)
365(7
4)
410(7
5)
460(7
6)
505(7
7)
5758(7
8)
650(7
9)
165(6
5)
195(6
7)
230(6
8)
270(7
0)
320(7
2)
355(7
2)
390(7
4)
425(7
5)
470(7
6)
510(7
7)
550(7
8)
600(7
9)
225(6
8)
270(6
8)
315(7
1)
350(7
2)
385(7
4)
420(7
5)
470(7
7)
495(7
8)
545(7
8)
590(7
9)
115(7
9)
140(8
0)
160(8
1)
195(8
1)
235(8
1)
260(8
2)
290(8
2)
325(8
3)
370(8
3)
410(8
4)
470(8
4)
520(8
4)
160(7
7)
195(7
9)
235(7
9)
260(8
0)
290(8
0)
325(8
1)
370(8
1)
410(8
1)
460(8
2)
520(8
3)
155(7
2)
190(7
4)
225(7
4)
255(7
4)
285(7
6)
320(7
6)
370(7
7)
410(8
4)
470(8
4)
520(8
4)
155(7
1)
190(7
2)
230(7
3)
255(7
3)
285(7
4)
320(7
5)
370(7
6)
410(7
7)
470(7
8)
540(7
9)
180(6
8)
215(7
0)
220(7
0)
285(7
1)
315(7
3)
350(7
4)
395(7
5)
430(7
6)
480(7
7)
525(7
8)
175(6
6)
215(6
8)
25(7
1)
290(7
2)
315(7
3)
345(7
4)
390(7
6)
430(7
7)
480(7
7)
520(7
8)
125(7
4)
150(7
5
180(7
5)
205(7
6)
230(7
7)
260(7
7)
295(7
7)
330(7
8)
380(8
1)
430(8
3)
125(7
8)
155(7
5)
185(7
8)
205(7
9)
230(8
0)
260(8
0)
295(8
0)
330(8
2)
380(8
2)
470(8
4)
0.6
41
0.4
43
0.3
20
0.2
53
0.2
06
0.1
64
0.1
25
1.1
00
1.0
78
0.0
61
0.8
22
0.5
68
0.4
10
0.3
25
0.2
65
0.2
11
0.1
61
0.1
30
0.1
02
0.0
80
1 3
65
1 6
40
1 8
30
1 9
85
2 1
75
2 3
70
2 7
15
3 2
40
3 8
95
4 2
40
1 9
00
2 0
70
2 2
90
2 4
55
2 8
25
3 0
80
3 4
10
3 8
60
4 4
50
4 9
70
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
2.0
2.0
2.0
2.0
2.5
2.5
2.5
2.5
2.5
2.5
30.0
31.6
33.4
34.8
36.4
38.2
40.8
43.7
47.2
49.6
38.6
40.3
42.2
43.6
46.4
48.3
50.9
54.1
57.7
60.3
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.0
2.0
2.0
2.5
2.5
0.7
27
0.5
24
0.3
87
0.2
68
0.1
93
0.1
53
0.1
24
0.0
99
0.0
75
0.0
60
0.0
47
0.0
37
0.6
41
0.4
43
0.3
20
0.2
53
0.2
06
0.1
64
0.1
25
0.1
00
0.0
78
0.0
61
0.9
27
0.6
68
0.4
94
0.3
42
0.2
47
0.1
96
0.1
59
0.1
28
0.0
98
0.0
79
0.0
63
0.0
51
0.8
22
0.5
68
0.4
10
0.3
25
0.2
65
0.2
11
0.1
61
0.1
30
0.1
02
0.0
80
0.1
47
0.1
40
0.1
33
0.1
25
0.1
18
0.1
14
0.1
11
0.1
07
0.1
02
0.0
99
0.0
96
0.0
94
0.2
87
0.2
77
0.2
68
0.2
57
0.2
46
0.2
40
0.2
34
0.2
27
0.2
19
0.2
11
0.2
05
0.2
00
164
179
195
219
244
264
284
308
345
383
423
454
140(7
1)
170(7
2)
200(7
2)
245(7
3)
290(7
4)
325(7
4)
360(7
5)
410(7
5)
460(7
8)
510(7
9)
580(8
0)
650(8
0)
155(7
3)
190(7
4)
225(7
4)
255(7
5)
285(7
5)
320(7
6)
370(7
7)
420(7
8)
480(7
9)
535(8
0)
165(6
6)
195(6
7)
230(6
9)
275(7
0)
320(7
2)
355(7
3)
390(7
4)
430(7
6)
470(7
7)
490(7
9)
555(8
0)
600(8
0)
170(6
8)
215(7
0)
255(7
2)
285(7
3)
315(7
4)
350(8
2)
395(7
5)
440(7
7)
480(7
8)
530(7
9)
115(7
6)
140(7
7)
160(7
7)
195(7
9)
230(8
0)
260(8
0)
290(8
0)
325(8
0)
370(8
1)
410(8
3)
470(8
3)
520(8
4)
125(7
8)
150(7
9)
180(8
0)
205(8
1)
230(8
0)
255(8
0)
295(8
1)
330(8
2)
380(8
2)
430(8
3)
130(7
4)
155(7
6)
180(7
6)
220(7
8)
260(7
9)
285(8
0)
315(8
0)
340(8
0)
380(8
2)
390(8
2)
445(8
2)
490(8
3)
130(7
8)
155(7
9)
180(8
0)
220(8
1)
255(8
1)
285(8
2)
310(8
2)
340(8
3)
375(8
3)
410(8
3)
440(8
4)
480(8
4)
180(7
6)
215(7
8)
255(8
0)
280(8
0)
310(8
1)
335(8
1)
370(8
1)
400(8
2)
440(8
3)
480(8
4)
135(7
7)
175(7
8)
205(7
9)
230(7
9)
255(8
0)
280(8
0)
315(8
1)
350(8
2)
385(8
3)
430(8
3)
125(7
4)
155(7
5)
180(7
5)
205(7
6)
230(7
7)
260(7
7)
295(7
7)
330(7
8)
380(8
1)
430(8
3)
140(7
8)
170(7
7)
205(7
9)
225(7
9)
245(8
0)
280(8
0)
310(8
1)
340(8
3)
380(8
4)
420(8
4)
235(6
7)
290(6
7)
350(6
8)
405(6
9)
460(6
9)
520(6
9)
590(7
0)
690(7
0)
800(7
0)
920(7
1)
235(6
5)
295(6
6)
355(6
7)
410(6
8)
460(6
9)
520(6
9)
610(6
9)
685(7
0)
800(7
0)
920(7
0)
240(6
2)
300(6
3)
360(6
4)
410(6
5)
470(6
5)
530(6
5)
610(6
7)
690(6
7)
800(6
8)
920(6
8)
265(6
2)
320(6
3)
385(6
4)
430(6
5)
475(6
6)
525(6
7)
590(6
8)
650(7
0)
750(7
0)
884(7
0)
260(6
0)
320(6
2)
385(6
3)
430(6
4)
480(6
6)
540(6
7)
610(6
8)
665(6
9)
750(6
9)
825(7
0)
260(5
8)
330(5
9)
380(6
0)
430(6
2)
480(6
3)
540(6
4)
610(6
6)
670(6
6)
750(6
7)
830(6
9)
160(6
5)
200(6
7)
185(6
0)
220(6
1)
185(5
0)
220(6
0)
165(6
2)
210(6
4)
185(6
7)
225(6
7)
275(6
7)
315(6
9)
360(6
9)
420(6
9)
480(7
0)
550(7
0)
640(7
0)
740(7
0)
185(6
5)
230(6
6)
280(6
7)
320(6
7)
360(6
7)
410(6
8)
490(6
8)
540(7
0)
640(7
0)
730(7
0)
190(6
2)
235(6
3)
280(6
3)
320(6
3)
365(6
4)
415(6
5)
490(6
6)
555(6
7)
650(6
7)
745(6
8)
205(6
2)
255(6
2)
305(6
3)
345(6
5)
385(6
5)
435(6
6)
500(6
7)
560(6
8)
640(6
8)
715(6
9)
205(6
2)
255(6
2)
305(6
3)
345(6
3)
385(6
4)
440(6
5)
510(6
5)
550(6
8)
630(6
8)
705(6
9)
205(5
8)
250(6
0)
300(6
0)
345(6
0)
385(6
1)
440(6
3)
500(6
3)
560(6
5)
640(6
6)
720(6
7)
Rate
d V
olt
age 8
.7/1
5kv
Rate
d V
olt
age 1
2.7
/22kv
Rate
d V
olt
age 1
9/3
3kv
Medium Voltage Cables 43
TIR
UP
AT
I Ty
pe
B -
Th
ree
Co
re
35
.0
37
.5
40
.5
44
.0
47
.5
51
.0
54
.0
58
.5
64
.5
71
.5
22
65
26
75
31
60
40
60
47
70
56
65
66
95
79
25
96
05
12
06
0
22
35
26
55
28
95
32
95
37
50
42
80
51
65
61
75
39
.5
41
.5
44
.5
48
.0
52
.0
55
.0
58
.5
62
.5
68
.0
74
.5
45
45
29
65
34
75
43
85
51
40
60
55
70
90
83
60
99
90
12
38
0
25
60
30
05
33
05
36
85
41
55
47
45
55
75
64
70
44 Medium Voltage Cables
44
.0
46
.5
49
.0
53
.0
57
.0
60
.5
63
.5
67
.5
73
.5
27
70
31
85
37
05
46
35
55
85
65
05
75
65
88
35
10
57
5
27
80
32
15
37
20
41
50
47
50
51
95
611
5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
0.1
33
0.1
26
0.1
20
0.1
13
0.1
07
0.1
03
0.1
00
0.0
97
0.0
93
16
4
17
9
19
5
21
9
24
4
26
4
28
4
30
8
34
5
49
.0
51
.5
54
.0
57
.5
62
.0
65
.0
68
.5
72
.5
78
.5
32
00
36
15
41
65
50
95
60
85
70
45
81
55
94
55
112
15
32
30
66
95
41
95
46
95
52
30
57
85
67
65
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
0.1
40
0.1
32
0.1
26
0.1
19
0.1
12
0.1
08
0.1
04
0.1
01
0.0
97
14
3
15
6
17
0
18
9
21
0
22
7
24
3
26
3
29
3
65
.5
65
.5
74
.0
77
.0
80
.0
84
.0
90
.5
53
10
63
05
73
45
83
80
95
10
10
88
5
12
71
0
43
60
48
75
64
60
60
05
65
55
72
35
82
50
8.0
8.0
8.0
8.0
8.0
8.0
8.0
0.1
39
0.1
31
0.1
23
0.1
19
0.1
15
0.1
11
0.1
06
13
3
14
7
16
2
17
3
18
5
19
9
22
0
Ra
ted
Vo
lta
ge
8.7
/15
kV
Ra
ted
Vo
lta
ge
12
.7/2
2 k
V
Ra
ted
Vo
lta
ge
19
/33
kV
18
0
22
0
26
5
31
0
35
0
40
0
47
0
23
0
29
0
35
0
40
0
45
5
52
0
61
0
18
0
22
5
27
0
31
0
35
5
40
5
48
0
Medium Voltage Cables 45
Fault rating - kA for 1 sec (Copper)Medium voltage Electric Cable - 6,6kV to 33kV
Earth Fault
* Applicable to PVC sheathed cable
Maximum permissible short-circuit current rating for Tirupati Plastomatics XLPE cables up to 33kV Copper conductors
Symmetrical Faults
46
Maximum permissible short-circuit current rating for Tirupati Plastomatics XLPE cables up to 33kV Aluminiumconductors
Fault rating - kA for 1 sec (Aluminium)Medium voltage Electric Cable - 6,6kV to 33kV
Earth Fault
Symmetrical Faults
25
35
50
70
95
120
150
185
240
300
7,4
11,1
12,0
12,9
17,3
18,3
19,4
20,8
25,5
27,2
10,4
12,2
13,1
17,6
18,7
19,7
20,8
25,0
26,8
28,6
16,5
17,2
19,7
20,8
25,0
25,9
27,2
28,6
30,3
32,1
21,3
28,1
29,4
30,3
31,6
33,0
34,7
TYPE A - 3-Core
92
Medium Voltage Cables
Medium Voltage Cables 47
Rating Factors Medium voltage Electric Cable - 6,6kV to 33kV
Tirupati cable in ground
Tirupati cable in ground
48
Number of cables
Rating factors
1 2 3
On metal tray
On metal ladder
On floor
On floor
Inceiling
touching
with spacing
touching
with spacing
touching
with spacing
touching
with spacing
touching
with spacing
12
12
12
12
0.970.97
0.970.97
1.001.00
1.001.00
0.94
0.94
0.94
0.94
0.89
0.89
0.850.83
0.960.94
0.860.82
1.001.00
0.80
0.90
0.80
0.90
0.76
0.81
0.740.71
0.930.90
0.740.71
1.001.00
0.86
0.87
0.86
0.87
0.57
0.77
Type of laying No. of
ladders or trays
Tirupati Plastomatics XLPE cable on trays, ladders or building structures
30 mm
30 mm
d max 30 mm
d max 30 mm
30 mm
30 mm
30 mm d max 30 mm
30 mm
30 mm d max 30 mm
30 mm
Rating Factors Medium voltage Electric Cable - 6,6kV to 33kV
Medium Voltage Cables
Medium Voltage Cables 49
TABLE 1 - 3.8/6.6 KV HT XLPE SINGLE CORE ALUMINIUM CONDUCTOR CABLES
“ " SINGLE CORE ALUMINIUM CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES CONFORMING TO IS: 7098 PART-2/1985:TIRUPATI PLASTOMATICS
UNARMOURED CABLE ALUMINIUM STRIP ARMOURED CABLE ALUMINIUM ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal Sizeof
Conductor
Nominal Thicknessof XLPE
Insulation
Nominal Thickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
MinimumThicknessof InnerSheath
Nominal Dimension
of Strip
MinimumThickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
Nominal Dimension
of Round Wire
MinimumThickness
of PVC Outer
Sheath
Approx.Overall
Diameterof
Cable
Approx.Weight of
Cable.
In Ground at
30° C.
In Duct at 30° C.
In Air at 40° C.
*Normal DeliveryLength.
Sq.mm.
35
50
70
95
120
150
185
240
300
400
500
630
800
1000
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
3.0
3.3
3.5
3.5
3.5
3.6
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.2
2.2
2.2
2.4
2.4
2.6
2.8
20.3
21.4
23.2
24.7
26.2
27.3
29.0
32.2
34.7
38.7
42.2
45.8
50.5
55.3
453
502
604
753
846
952
1103
1347
1548
1953
2405
2855
3453
4247
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.40
0.40
0.40
0.50
0.50
0.50
0.60
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
1.40
1.40
1.40
1.40
1.40
1.40
1.56
1.56
1.56
1.56
1.72
1.88
1.88
2.04
21.3
22.2
24.2
25.4
27.3
28.8
31.3
32.8
36.4
40.4
43.8
47.9
51.3
56.8
553
605
752
847
947
1105
1253
1503
1755
2204
2652
3204
3752
4604
1.6
1.6
1.6
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.0
2.0
2.5
2.5
1.40
1.40
1.40
1.40
1.40
1.56
1.56
1.56
1.56
1.72
1.88
1.88
2.04
2.20
22.8
23.1
25.9
26.8
29.3
30.8
32.9
35.9
38.4
42.9
46.8
49.8
55.3
60.8
624
705
803
954
1055
1203
1402
1704
2005
2455
2954
3453
4304
5155
120
140
175
205
235
260
295
340
385
440
495
560
620
680
105
125
155
180
205
230
260
300
335
380
430
480
530
580
145
170
215
260
305
345
395
470
540
630
730
840
960
1070
500
500
500
500
500
500
500
500
500
500
500
500
500
500
mm mm mm mm mm mm mm mm mm mm Amps. Amps. Amps. Mtrs.Kg/Km Kg/Km Kg/Km
TABLE 2 - 3.8/6.6 KV (E) HT XLPE SINGLE CORE COPPER CONDUCTOR CABLES
“ " SINGLE CORE COPPER CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES CONFORMING TO IS: 7098 PART-2/1985:TIRUPATI PLASTOMATICS
UNARMOURED CABLE ALUMINIUM STRIP ARMOURED CABLE ALUMINIUM ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal Sizeof
Conductor
Nominal Thicknessof XLPE
Insulation
Nominal Thickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
MinimumThicknessof InnerSheath
Nominal Dimension
of Strip
MinimumThickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
Nominal Dimension
of Round Wire
MinimumThickness
of PVC Outer
Sheath
Approx.Overall
Diameterof
Cable
Approx.Weight of
Cable.
In Ground at
30° C.
In Duct at 30° C.
In Air at 40° C.
*Normal DeliveryLength.
Sq.mm.
35
50
70
95
120
150
185
240
300
400
500
630
800
1000
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
3.0
3.3
3.5
3.5
3.5
3.6
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.2
2.2
2.2
2.4
2.4
2.6
2.8
20.5
21.3
23.4
24.2
25.8
27.4
29.4
32.3
34.8
38.8
42.3
45.8
50.2
54.8
675
853
1055
1304
1603
1905
2252
2853
3454
4455
5503
6754
8455
10452
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.40
0.40
0.40
0.50
0.50
0.50
0.60
1.40
1.40
1.40
1.40
1.40
1.40
1.56
1.56
1.56
1.56
1.72
1.88
1.88
2.04
21.3
22.4
24.5
25.8
27.3
28.8
31.4
32.8
35.8
40.4
43.3
47.8
51.4
56.8
755
904
1153
1452
1701
2055
2403
3005
3604
4653
5755
7102
8703
10805
1.6
1.6
1.6
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.0
2.0
2.5
2.5
1.40
1.40
1.40
1.40
1.40
1.56
1.56
1.56
1.56
1.72
1.88
1.88
2.04
2.20
22.8
23.7
25.6
27.2
29.3
30.8
32.8
35.6
37.3
42.8
46.7
50.3
55.4
60.8
854
1005
1254
1553
1805
2152
2553
3204
3853
4954
6055
7353
9252
11355
155
185
225
265
300
335
380
435
490
550
610
680
740
790
140
160
195
235
265
295
330
380
425
480
530
580
630
670
185
220
275
340
390
440
510
600
680
790
910
1030
1140
1250
500
500
500
500
500
500
500
500
500
500
500
500
500
500
mm mm mm mm mm mm mm mm mm mm Amps. Amps. Amps. Mtrs.Kg/Km Kg/Km Kg/Km
The above data is approximate and subject to manufacturing tolerance. * Delivery Length tolerance is ± 5% Length more than normal as per customer request.
High Voltage Cables to IS : 7098 (Part - 2)
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
50
TABLE 3 - 6.35/11 KV 6.6/6.6 KV (UE) HT XLPE SINGLE CORE ALUMINIUM CONDUCTOR CABLES
“ " SINGLE CORE ALUMINIUM CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES CONFORMING TO IS: 7098 PART-2/1985:TIRUPATI PLASTOMATICS
UNARMOURED CABLE ALUMINIUM STRIP ARMOURED CABLE ALUMINIUM ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal Sizeof
Conductor
Nominal Thicknessof XLPE
Insulation
Nominal Thickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
MinimumThicknessof InnerSheath
Nominal Dimension
of Strip
MinimumThickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
Nominal Dimension
of Round Wire
MinimumThickness
of PVC Outer
Sheath
Approx.Overall
Diameterof
Cable
Approx.Weight of
Cable.
In Ground at
30° C.
In Duct at 30° C.
In Air at 40° C.
*Normal DeliveryLength.
Sq.mm.
35
50
70
95
120
150
185
240
300
400
500
630
800
1000
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
2.0
2.0
2.0
2.0
2.0
2.0
2.2
2.2
2.2
2.2
2.4
2.4
2.6
2.8
21.7
22.8
24.8
25.8
27.7
29.4
31.8
35.4
36.3
39.2
42.7
46.3
50.2
55.3
554
603
705
802
953
1055
1254
1455
1654
2005
2455
2903
3504
4252
0.30
0.30
0.30
0.30
0.30
0.30
0.40
0.40
0.40
0.40
0.50
0.50
0.50
0.60
1.40
1.40
1.40
1.40
1.40
1.56
1.56
1.56
1.56
1.72
1.72
1.88
1.88
2.04
23.2
24.3
25.7
27.8
29.3
30.8
33.3
35.3
37.4
40.8
44.5
47.7
51.7
56.2
653
704
805
955
1055
1203
1404
1602
1854
2255
2653
3205
3805
4604
1.6
1.6
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.0
2.0
2.0
2.5
2.5
1.40
1.40
1.40
1.40
1.56
1.56
1.56
1.56
1.56
1.72
1.88
1.88
2.04
2.20
24.2
25.3
27.4
29.3
31.5
32.4
35.3
38.5
40.3
43.8
46.7
50.2
55.4
60.8
753
805
954
1053
1204
1352
1603
1855
2104
2555
3003
3454
4302
5155
120
140
175
205
235
260
295
340
385
440
495
560
620
680
105
125
155
180
205
230
260
300
335
380
430
480
530
580
145
170
215
260
305
345
395
470
540
630
730
840
960
1070
500
500
500
500
500
500
500
500
500
500
500
500
500
500
mm mm mm mm mm mm mm mm mm mm Amps. Amps. Amps. Mtrs.Kg/Km Kg/Km Kg/Km
“ " SINGLE CORE COPPER CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES CONFORMING TO IS: 7098 PART-2/1985:TIRUPATI PLASTOMATICS
UNARMOURED CABLE ALUMINIUM STRIP ARMOURED CABLE ALUMINIUM ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal Sizeof
Conductor
Nominal Thicknessof XLPE
Insulation
Nominal Thickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
MinimumThicknessof InnerSheath
Nominal Dimension
of Strip
MinimumThickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
Nominal Dimension
of Round Wire
MinimumThickness
of PVC Outer
Sheath
Approx.Overall
Diameterof
Cable
Approx.Weight of
Cable.
In Ground at
30° C.
In Duct at 30° C.
In Air at 40° C.
*Normal DeliveryLength.
Sq.mm.
35
50
70
95
120
150
185
240
300
400
500
630
800
1000
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
2.0
2.0
2.0
2.0
2.0
2.0
2.2
2.2
2.2
2.2
2.4
2.4
2.6
2.8
755
904
1152
1405
1654
1953
2405
2903
3502
4505
5503
6804
8452
10451
0.30
0.30
0.30
0.30
0.30
0.30
0.40
0.40
0.40
0.40
0.50
0.50
0.50
0.60
1.40
1.40
1.40
1.40
1.40
1.56
1.56
1.56
1.56
1.72
1.72
1.88
1.88
2.04
23.3
24.4
25.8
27.7
29.4
30.8
32.8
34.7
37.3
40.7
44.4
47.8
51.6
56.7
852
1005
1253
1555
1801
2152
2554
3103
3705
4752
5801
7104
8753
10805
1.6
1.6
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.0
2.0
2.0
2.5
2.5
1.40
1.40
1.40
1.40
1.56
1.56
1.56
1.56
1.56
1.72
1.88
1.88
2.04
2.20
24.4
25.0
27.2
29.8
31.5
32.7
33.5
38.8
40.7
44.2
46.4
50.3
55.5
60.8
952
1115
1354
1653
1955
2251
2752
3354
3955
5053
6102
7354
9255
11353
155
185
225
265
300
335
380
435
490
550
610
680
740
790
140
160
195
235
265
295
330
380
425
480
530
580
630
670
185
220
275
340
390
440
510
600
680
790
910
1030
1140
1250
500
500
500
500
500
500
500
500
500
500
500
500
500
500
mm mm mm mm mm mm mm mm mm mm Amps. Amps. Amps. Mtrs.Kg/Km Kg/Km Kg/Km
The above data is approximate and subject to manufacturing tolerance. * Delivery Length tolerance is ± 5% Length more than normal as per customer request.
TABLE 4 - 6.35/11 KV 6.6/6.6 KV (UE) HT XLPE SINGLE CORE COPPER CONDUCTOR CABLES
21.8
23.4
24.8
26.3
28.5
28.8
31.7
34.7
36.3
39.4
42.8
46.4
50.3
55.4
Medium Voltage Cables
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
Medium Voltage Cables 51
TABLE 5 - 11 / 11 KV (UE) HT XLPE SINGLE CORE ALUMINIUM CONDUCTOR CABLES
“ " SINGLE CORE ALUMINIUM CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES CONFORMING TO IS: 7098 PART-2/1985:TIRUPATI PLASTOMATICS
UNARMOURED CABLE ALUMINIUM STRIP ARMOURED CABLE ALUMINIUM ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal Sizeof
Conductor
Nominal Thicknessof XLPE
Insulation
Nominal Thickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
MinimumThicknessof InnerSheath
Nominal Dimension
of Strip
MinimumThickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
Nominal Dimension
of Round Wire
MinimumThickness
of PVC Outer
Sheath
Approx.Overall
Diameterof
Cable
Approx.Weight of
Cable.
In Ground at
30° C.
In Duct at 30° C.
In Air at 40° C.
*Normal DeliveryLength.
Sq.mm.
70
95
120
150
185
240
300
400
500
630
800
1000
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
2.0
2.0
2.2
2.2
2.2
2.2
2.2
2.4
2.4
2.6
2.8
2.8
28.7
30.2
32.3
33.8
35.7
37.7
39.8
42.9
45.6
50.3
54.4
59.2
855
983
1152
1264
1433
1655
1902
2305
2703
3204
3885
4604
0.30
0.30
0.40
0.40
0.40
0.40
0.40
0.50
0.50
0.50
0.60
0.60
1.56
1.56
1.56
1.56
1.56
1.56
1.72
1.72
1.88
1.88
2.04
2.2
30.3
32.5
33.8
35.4
36.8
38.5
41.7
45.3
48.4
51.8
56.4
61.3
1055
1204
1303
1455
1601
1852
2154
2603
3005
3504
4202
5003
1.6
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.5
2.5
2.5
2.5
1.56
1.56
1.56
1.56
1.56
1.72
1.72
1.88
2.04
2.04
2.2
2.36
31.4
34.2
36.4
37.3
39.5
41.8
44.3
47.4
52.3
55.4
60.5
65.2
1154
1355
1502
1655
1851
2153
2405
2904
3505
4052
4801
5653
175
205
235
260
295
340
385
440
495
560
620
680
155
180
205
230
260
300
335
380
430
480
530
580
215
260
305
345
395
470
540
630
730
840
960
1070
500
500
500
500
500
500
500
500
500
500
500
500
mm mm mm mm mm mm mm mm mm mm Amps. Amps. Amps. Mtrs.Kg/Km Kg/Km Kg/Km
“ " SINGLE CORE COPPER CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES CONFORMING TO IS: 7098 PART-2/1985:TIRUPATI PLASTOMATICS
UNARMOURED CABLE ALUMINIUM STRIP ARMOURED CABLE ALUMINIUM ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal Sizeof
Conductor
Nominal Thicknessof XLPE
Insulation
Nominal Thickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
MinimumThicknessof InnerSheath
Nominal Dimension
of Strip
MinimumThickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
Nominal Dimension
of Round Wire
MinimumThickness
of PVC Outer
Sheath
Approx.Overall
Diameterof
Cable
Approx.Weight of
Cable.
In Ground at
30° C.
In Duct at 30° C.
In Air at 40° C.
*Normal DeliveryLength.
Sq.mm.
1305
1553
1905
2202
2601
3154
3755
4803
5804
7103
8855
10804
0.30
0.30
0.40
0.40
0.40
0.40
0.40
0.50
0.50
0.50
0.60
0.60
1505
1803
2054
2402
2755
3351
4003
5105
6104
7403
9152
11205
1604
1955
2253
2602
3004
3653
4255
5405
6603
7952
9755
11854
225
265
300
335
380
435
490
550
610
680
740
790
195
235
265
295
330
380
425
480
530
580
630
670
275
340
390
440
510
600
680
790
910
1030
1140
1250
500
500
500
500
500
500
500
500
500
500
500
500
mm mm mm mm mm mm mm mm mm mm Amps. Amps. Amps. Mtrs.Kg/Km Kg/Km Kg/Km
The above data is approximate and subject to manufacturing tolerance. * Delivery Length tolerance is ± 5% Length more than normal as per customer request.
TABLE 6 - 11 / 11 KV (UE) HT XLPE SINGLE CORE COPPER CONDUCTOR CABLES
70
95
120
150
185
240
300
400
500
630
800
1000
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
2.0
2.0
2.2
2.2
2.2
2.2
2.2
2.4
2.4
2.6
2.8
2.8
28.2
30.3
31.8
33.2
35.8
37.3
39.4
43.5
46.2
50.3
54.4
59.3
1.56
1.56
1.56
1.56
1.56
1.56
1.72
1.72
1.88
1.88
2.04
2.2
29.7
32.4
33.3
35.1
37.3
39.4
41.8
45.4
48.3
51.7
56.2
61.4
1.6
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.5
2.5
2.5
2.5
1.56
1.56
1.56
1.56
1.56
1.72
1.72
1.88
2.04
2.04
2.2
2.36
31.7
34.2
36.3
37.4
39.5
42.2
44.3
47.4
52.5
55.3
60.4
65.2
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
52
TABLE 7 - 12.7 / 22 KV HT XLPE SINGLE CORE ALUMINIUM CONDUCTOR CABLES
“ " SINGLE CORE ALUMINIUM CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES CONFORMING TO IS: 7098 PART-2/1985:TIRUPATI PLASTOMATICS
UNARMOURED CABLE ALUMINIUM STRIP ARMOURED CABLE ALUMINIUM ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal Sizeof
Conductor
Nominal Thicknessof XLPE
Insulation
Nominal Thickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
MinimumThicknessof InnerSheath
Nominal Dimension
of Strip
MinimumThickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
Nominal Dimension
of Round Wire
MinimumThickness
of PVC Outer
Sheath
Approx.Overall
Diameterof
Cable
Approx.Weight of
Cable.
In Ground at
30° C.
In Duct at 30° C.
In Air at 40° C.
*Normal DeliveryLength.
Sq.mm.
95
120
150
185
240
300
400
500
630
800
1000
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
2.2
2.2
2.2
2.2
2.2
2.2
2.4
2.6
2.6
2.8
3.0
32.4
34.5
35.2
37.3
39.5
41.4
44.8
47.7
51.8
56.3
61.2
1105
1202
1353
1505
1751
2005
2404
2852
3303
4005
4804
0.40
0.40
0.40
0.40
0.40
0.40
0.50
0.50
0.50
0.60
0.60
1.56
1.56
1.56
1.56
1.56
1.72
1.88
1.88
2.04
2.04
2.2
33.2
35.4
36.3
38.5
40.8
43.4
47.3
50.2
54.5
58.3
62.1
1255
1402
1534
1703
1951
2255
2704
3102
3703
4352
5154
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.5
2.5
2.5
2.5
1.56
1.56
1.56
1.72
1.72
1.72
1.88
2.04
2.04
2.20
2.36
36.2
37.8
39.2
41.4
43.3
45.4
49.5
53.8
57.2
61.5
66.4
1454
1605
1753
2002
2253
2505
3001
3652
4155
5004
5803
205
230
260
290
335
380
430
485
550
610
660
180
200
225
255
290
325
370
420
470
520
560
270
310
350
400
470
540
630
730
840
950
1060
500
500
500
500
500
500
500
500
500
500
500
mm mm mm mm mm mm mm mm mm mm Amps. Amps. Amps. Mtrs.Kg/Km Kg/Km Kg/Km
“ " SINGLE CORE COPPER CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES CONFORMING TO IS: 7098 PART-2/1985:TIRUPATI PLASTOMATICS
The above data is approximate and subject to manufacturing tolerance. * Delivery Length tolerance is ± 5% Length more than normal as per customer request.
TABLE 8 - 12.7 / 22 KV HT XLPE SINGLE CORE COPPER CONDUCTOR CABLES
UNARMOURED CABLE ALUMINIUM STRIP ARMOURED CABLE ALUMINIUM ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal Sizeof
Conductor
Nominal Thicknessof XLPE
Insulation
Nominal Thickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
MinimumThicknessof InnerSheath
Nominal Dimension
of Strip
MinimumThickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
Nominal Dimension
of Round Wire
MinimumThickness
of PVC Outer
Sheath
Approx.Overall
Diameterof
Cable
Approx.Weight of
Cable.
In Ground at
30° C.
In Duct at 30° C.
In Air at 40° C.
*Normal DeliveryLength.
Sq.mm.
95
120
150
185
240
300
400
500
630
800
1000
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
2.2
2.2
2.2
2.2
2.2
2.2
2.4
2.6
2.6
2.8
3.0
32.2
34.4
35.3
36.6
38.3
40.8
44.8
47.7
51.8
56.3
61.2
1655
1953
2257
2653
3205
3854
4905
5952
7203
8955
11004
0.40
0.40
0.40
0.40
0.40
0.40
0.50
0.50
0.50
0.60
0.60
1.56
1.56
1.56
1.56
1.56
1.72
1.88
1.88
2.04
2.04
2.20
32.7
34.8
36.3
38.5
40.8
43.2
46.8
50.3
54.4
57.8
62.7
1853
2152
2455
2854
3455
4102
5203
6204
7605
9303
11355
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.5
2.5
2.5
2.5
1.56
1.56
1.56
1.72
1.72
1.72
1.88
2.04
2.04
2.20
2.36
36.2
37.7
39.4
41.5
43.3
45.4
49.5
53.8
57.3
61.4
66.5
2054
2355
2703
3155
3752
4354
5503
6755
8052
9904
12005
265
300
330
375
430
480
540
600
660
720
760
230
260
290
325
370
415
465
520
570
620
660
345
400
450
510
600
690
790
910
1020
1140
1240
500
500
500
500
500
500
500
500
500
500
500
mm mm mm mm mm mm mm mm mm mm Amps. Amps. Amps. Mtrs.Kg/Km Kg/Km Kg/Km
Medium Voltage Cables
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
Medium Voltage Cables 53
TABLE 9 - 19 / 33 KV HT XLPE SINGLE CORE ALUMINIUM CONDUCTOR CABLES
“ " SINGLE CORE ALUMINIUM CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES CONFORMING TO IS: 7098 PART-2/1985:TIRUPATI PLASTOMATICS
UNARMOURED CABLE ALUMINIUM STRIP ARMOURED CABLE ALUMINIUM ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal Sizeof
Conductor
Nominal Thicknessof XLPE
Insulation
Nominal Thickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
MinimumThicknessof InnerSheath
Nominal Dimension
of Strip
MinimumThickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
Nominal Dimension
of Round Wire
MinimumThickness
of PVC Outer
Sheath
Approx.Overall
Diameterof
Cable
Approx.Weight of
Cable.
In Ground at
30° C.
In Duct at 30° C.
In Air at 40° C.
*Normal DeliveryLength.
Sq.mm.
95
120
150
185
240
300
400
500
630
800
1000
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
2.2
2.2
2.2
2.4
2.4
2.6
2.6
2.8
2.8
3.0
3.2
37.8
39.4
40.3
43.4
45.1
48.5
51.3
54.2
57.4
62.3
67.5
1405
1553
1704
1905
2202
2504
2903
3405
3902
4605
5452
0.40
0.40
0.40
0.50
0.50
0.50
0.50
0.60
0.60
0.60
0.70
1.56
1.72
1.72
1.72
1.88
1.88
2.04
2.04
2.2
2.36
2.36
39.3
41.2
42.5
44.8
47.7
48.5
52.8
56.3
60.4
64.3
69.4
1602
1804
1955
2203
2505
2754
3255
3705
4303
5054
5903
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.5
2.5
2.5
2.5
1.72
1.72
1.72
1.88
1.88
2.04
2.04
2.2
2.36
2.36
2.52
41.8
43.2
44.7
47.3
49.8
52.2
55.3
60.4
63.5
67.3
72.8
1905
2054
2203
2501
2764
3103
3555
4254
4903
5605
6553
200
230
260
290
335
380
430
485
550
610
660
180
200
225
255
290
325
370
420
470
520
560
270
310
350
400
470
540
630
730
840
950
1060
500
500
500
500
500
500
500
500
500
500
500
mm mm mm mm mm mm mm mm mm mm Amps. Amps. Amps. Mtrs.Kg/Km Kg/Km Kg/Km
“ " SINGLE CORE COPPER CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES CONFORMING TO IS: 7098 PART-2/1985:TIRUPATI PLASTOMATICS
The above data is approximate and subject to manufacturing tolerance. * Delivery Length tolerance is ± 5% Length more than normal as per customer request.
TABLE 10 - 19 / 33 KV HT XLPE SINGLE CORE COPPER CONDUCTOR CABLES
UNARMOURED CABLE ALUMINIUM STRIP ARMOURED CABLE ALUMINIUM ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal Sizeof
Conductor
Nominal Thicknessof XLPE
Insulation
Nominal Thickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
MinimumThicknessof InnerSheath
Nominal Dimension
of Strip
MinimumThickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
Nominal Dimension
of Round Wire
MinimumThickness
of PVC Outer
Sheath
Approx.Overall
Diameterof
Cable
Approx.Weight of
Cable.
In Ground at
30° C.
In Duct at 30° C.
In Air at 40° C.
*Normal DeliveryLength.
Sq.mm.
95
120
150
185
240
300
400
500
630
800
1000
8.8
8.8
8.8
8.8
8.8
8.8
8.8
8.8
8.8
8.8
8.8
2.2
2.2
2.2
2.4
2.4
2.6
2.6
2.8
2.8
3.0
3.2
2005
2303
2602
3055
3654
4353
5355
6454
7003
9555
11604
2205
2553
2854
3305
4003
4605
5702
6803
8205
10003
12104
2555
2803
3102
3655
4254
4951
6052
7354
8805
10603
12752
265
300
330
375
430
480
540
600
660
720
760
230
260
290
325
370
415
465
520
570
620
660
345
400
450
510
600
690
790
910
1020
1140
1240
500
500
500
500
500
500
500
500
500
500
500
mm mm mm mm mm mm mm mm mm mm Amps. Amps. Amps. Mtrs.Kg/Km Kg/Km Kg/Km
37.7
39.3
40.5
43.4
45.2
48.5
51.4
54.3
57.8
62.7
67.4
0.40
0.40
0.40
0.50
0.50
0.50
0.50
0.60
0.60
0.60
0.70
1.56
1.72
1.72
1.72
1.88
1.88
2.04
2.04
2.20
2.36
2.36
39.2
41.3
42.5
44.8
47.4
49.3
52.2
56.4
60.5
64.3
69.4
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.5
2.5
2.5
2.5
1.72
1.72
1.72
1.88
1.88
2.04
2.04
2.20
2.36
2.36
2.52
41.8
43.3
44.8
47.5
49.8
52.4
55.3
60.2
63.4
67.3
72.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
54
TABLE 11 - 33 / 33 KV (UE) HT XLPE SINGLE CORE ALUMINIUM CONDUCTOR CABLES
“ " SINGLE CORE ALUMINIUM CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES CONFORMING TO IS: 7098 PART-2/1985:TIRUPATI PLASTOMATICS
UNARMOURED CABLE ALUMINIUM STRIP ARMOURED CABLE ALUMINIUM ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal Sizeof
Conductor
Nominal Thicknessof XLPE
Insulation
Nominal Thickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
MinimumThicknessof InnerSheath
Nominal Dimension
of Strip
MinimumThickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
Nominal Dimension
of Round Wire
MinimumThickness
of PVC Outer
Sheath
Approx.Overall
Diameterof
Cable
Approx.Weight of
Cable.
In Ground at
30° C.
In Duct at 30° C.
In Air at 40° C.
*Normal DeliveryLength.
Sq.mm.
120
150
185
240
300
400
500
630
800
1000
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
2.2
2.4
2.4
2.4
2.6
2.6
2.8
3.0
3.0
3.2
41.8
43.2
45.3
47.7
50.4
53.2
56.8
60.4
64.3
69.5
1705
1903
2104
2352
2653
3104
3603
4205
4853
5705
0.40
0.40
0.50
0.50
0.50
0.50
0.60
0.60
0.60
0.70
1.72
1.72
1.72
1.88
1.88
2.04
2.04
2.20
2.36
2.52
43.2
44.7
46.8
49.2
51.3
55.4
58.3
61.7
66.4
71.2
2005
2153
2404
2705
3002
3455
3953
4554
5305
6253
2.00
2.00
2.00
2.50
2.50
2.50
2.50
2.50
3.15
3.15
1.72
1.88
1.88
2.04
2.04
2.20
2.20
2.36
2.52
2.68
45.7
47.8
49.8
53.3
55.2
58.7
62.2
65.3
71.2
76.4
2253
2502
2704
3205
3502
4003
4552
5205
6204
7255
230
260
290
335
380
430
485
550
610
660
200
225
255
290
325
370
420
470
520
560
310
350
400
470
540
630
730
840
950
1060
500
500
500
500
500
500
500
500
500
500
mm mm mm mm mm mm mm mm mm mm Amps. Amps. Amps. Mtrs.Kg/Km Kg/Km Kg/Km
“ " SINGLE CORE COPPER CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES CONFORMING TO IS: 7098 PART-2/1985:TIRUPATI PLASTOMATICS
The above data is approximate and subject to manufacturing tolerance. * Delivery Length tolerance is ± 5% Length more than normal as per customer request.
TABLE 12 - 33 / 33 KV (UE) HT XLPE SINGLE CORE COPPER CONDUCTOR CABLES
UNARMOURED CABLE ALUMINIUM STRIP ARMOURED CABLE ALUMINIUM ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal Sizeof
Conductor
Nominal Thicknessof XLPE
Insulation
Nominal Thickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
MinimumThicknessof InnerSheath
Nominal Dimension
of Strip
MinimumThickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
Nominal Dimension
of Round Wire
MinimumThickness
of PVC Outer
Sheath
Approx.Overall
Diameterof
Cable
Approx.Weight of
Cable.
In Ground at
30° C.
In Duct at 30° C.
In Air at 40° C.
*Normal DeliveryLength.
Sq.mm.
120
150
185
240
300
400
500
630
800
1000
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
2.2
2.4
2.4
2.4
2.6
2.6
2.8
3.0
3.0
3.2
41.8
43.3
45.4
47.7
50.2
53.4
56.2
60.3
64.4
68.8
2453
2854
3255
3852
4555
5603
6704
8105
9803
11902
0.40
0.40
0.50
0.50
0.50
0.50
0.60
0.60
0.60
0.70
1.72
1.72
1.72
1.88
1.88
2.04
2.04
2.20
2.36
2.52
43.2
44.8
46.7
49.2
51.1
55.3
58.4
61.8
66.3
71.2
2752
3055
3503
4204
4851
5955
7054
8453
10254
12455
2.00
2.00
2.00
2.50
2.50
2.50
2.50
2.50
3.15
3.15
1.72
1.88
1.88
2.04
2.04
2.20
2.20
2.36
2.52
2.68
45.8
47.2
49.4
53.5
55.3
58.7
62.2
65.7
71.2
76.3
3005
3402
3851
4654
5353
6505
7652
9105
11203
13452
300
330
375
430
480
540
600
660
720
760
260
290
325
370
415
465
520
570
620
660
400
450
510
600
690
790
910
1020
1140
1240
500
500
500
500
500
250
250
250
250
200
mm mm mm mm mm mm mm mm mm mm Amps. Amps. Amps. Mtrs.Kg/Km Kg/Km Kg/Km
Medium Voltage Cables
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
Medium Voltage Cables 55
TABLE 13 - 1.9 / 3.3 KV (E) & 3.3/3.3 KV (UE) HT XLPE THREE CORE ALUMINIUM CONDUCTOR CABLES
“ " THREE CORE ALUMINIUM CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES CONFORMING TO IS: 7098 PART-2/1985:TIRUPATI PLASTOMATICS
UNARMOURED CABLE STEEL STRIP ARMOURED CABLE STEEL ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal Sizeof
Conductor
Nominal Thicknessof XLPE
Insulation
Nominal Thickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
MinimumThicknessof InnerSheath
Nominal Dimension
of Strip
MinimumThickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
Nominal Dimension
of Round Wire
MinimumThickness
of PVC Outer
Sheath
Approx.Overall
Diameterof
Cable
Approx.Weight of
Cable.
In Ground at
30° C.
In Duct at 30° C.
In Air at 40° C.
*Normal DeliveryLength.
Sq.mm.
35
50
70
95
120
150
185
240
300
400
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
0.4
0.4
0.5
0.5
0.5
0.6
0.6
0.7
0.7
0.7
2.2
2.2
2.4
2.6
2.6
2.8
3.0
3.0
3.2
3.6
38.5
40.2
44.7
48.3
52.2
55.7
60.3
65.5
70.7
78.3
1502
1703
2155
2604
3001
3503
4155
4904
5853
7302
1.56
1.72
1.72
1.80
2.04
2.04
2.20
2.36
2.52
2.68
37.2
39.7
44.5
47.8
51.3
54.7
59.2
64.7
70.5
76.7
1955
2204
2653
3152
3651
4105
4804
5752
6655
8102
2.0
2.0
2.0
2.5
2.5
2.5
2.5
2.5
3.15
3.15
1.72
1.72
1.88
2.04
2.04
2.20
2.36
2.36
2.68
2.84
40.4
42.2
47.2
51.3
55.7
58.8
63.4
68.2
75.3
82.4
2605
2903
3451
4404
5002
5555
6353
7354
9255
11002
115
130
160
190
220
245
275
315
355
400
97
115
140
165
190
210
240
275
310
350
125
150
190
230
260
295
335
395
450
520
500
500
500
500
500
500
500
500
500
500
mm mm mm mm mm mm mm mm mm mm Amps. Amps. Amps. Mtrs.Kg/Km Kg/Km Kg/Km
“ " THREE CORE COPPER CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES CONFORMING TO IS: 7098 PART-2/1985:TIRUPATI PLASTOMATICS
The above data is approximate and subject to manufacturing tolerance. * Delivery Length tolerance is ± 5% Length more than normal as per customer request.
TABLE 14 - 1.9 / 3.3 KV (E) & 3.3/3.3 KV (UE) HT XLPE THREE CORE COPPER CONDUCTOR CABLES
UNARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal Sizeof
Conductor
Nominal Thicknessof XLPE
Insulation
Nominal Thickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
MinimumThicknessof InnerSheath
Nominal Dimension
of Strip
MinimumThickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
Nominal Dimension
of Round Wire
MinimumThickness
of PVC Outer
Sheath
Approx.Overall
Diameterof
Cable
Approx.Weight of
Cable.
In Ground at
30° C.
In Duct at 30° C.
In Air at 40° C.
*Normal DeliveryLength.
Sq.mm.
35
50
70
95
120
150
185
240
300
400
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
0.4
0.4
0.5
0.5
0.5
0.6
0.6
0.7
0.7
0.7
2.2
2.2
2.4
2.6
2.6
2.8
3.0
3.0
3.2
3.6
38.2
40.4
44.8
48.7
52.2
55.3
60.5
65.4
70.2
78.4
2152
2653
3455
4354
5252
6303
7602
9354
11405
14753
1.56
1.72
1.72
1.80
2.04
2.04
2.2
2.36
2.52
2.68
37.2
39.7
44.2
47.3
51.2
54.6
59.2
64.7
70.3
76.2
2605
3153
3954
4951
5902
6905
8252
10253
12254
15555
2.00
2.00
2.00
2.50
2.50
2.50
2.50
2.50
3.15
3.15
1.72
1.72
1.88
2.04
2.04
2.20
2.36
2.36
2.68
2.84
40.2
42.1
47.2
51.4
55.7
58.6
63.2
68.3
75.4
82.5
3255
3803
4755
6152
72001
8355
9803
11804
14855
18452
145
170
210
250
280
310
350
400
445
500
125
150
180
215
240
270
305
350
390
440
165
195
240
295
335
380
430
500
510
650
500
500
500
500
500
500
500
500
500
250
mm mm mm mm mm mm mm mm mm Amps. Amps. Amps. Mtrs.Kg/Km Kg/Km Kg/Km
STEEL STRIP ARMOURED CABLE STEEL ROUND WIRE ARMOURED CABLE
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
mm
56
TABLE 15 - 3.8 / 6.6 KV (E) HT XLPE THREE CORE ALUMINIUM CONDUCTOR CABLES
“ " THREE CORE ALUMINIUM CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES CONFORMING TO IS: 7098 PART-2/1985:TIRUPATI PLASTOMATICS
UNARMOURED CABLE STEEL STRIP ARMOURED CABLE STEEL ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal Sizeof
Conductor
Nominal Thicknessof XLPE
Insulation
Nominal Thickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
MinimumThicknessof InnerSheath
Nominal Dimension
of Strip
MinimumThickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
Nominal Dimension
of Round Wire
MinimumThickness
of PVC Outer
Sheath
Approx.Overall
Diameterof
Cable
Approx.Weight of
Cable.
In Ground at
30° C.
In Duct at 30° C.
In Air at 40° C.
*Normal DeliveryLength.
Sq.mm.
35
50
70
95
120
150
185
240
300
400
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
3.0
3.3
0.4
0.5
0.5
0.5
0.5
0.6
0.6
0.7
0.7
0.7
2.2
2.4
2.6
2.6
2.8
2.8
3.0
3.2
3.4
3.8
40.2
43.4
47.5
51.2
55.3
58.4
63.1
68.3
74.5
83.2
1603
1954
2352
2805
3303
3801
4402
5304
6305
8003
1.72
1.72
1.88
1.88
2.04
2.20
2.20
2.36
2.52
2.84
40.2
42.7
47.3
50.8
55.2
58.4
62.3
67.8
73.8
82.2
2202
2504
3003
3402
4005
4502
5154
6103
7165
9002
2.00
2.00
2.00
2.50
2.50
2.50
2.50
3.15
3.15
4.00
1.72
1.88
1.88
2.04
2.20
2.20
2.36
2.52
2.68
3.00
43.2
45.7
49.8
54.2
58.1
61.4
66.3
73.5
78.3
89.2
2805
3203
3704
4705
5402
5905
6703
8604
9903
13205
115
130
160
190
220
245
275
315
355
400
97
115
140
165
190
210
240
275
310
350
125
150
190
230
260
295
335
395
450
520
500
500
500
500
500
500
500
500
500
500
mm mm mm mm mm mm mm mm mm Amps. Amps. Amps. Mtrs.Kg/Km Kg/Km Kg/Km
“ " THREE CORE COPPER CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES CONFORMING TO IS: 7098 PART-2/1985:TIRUPATI PLASTOMATICS
The above data is approximate and subject to manufacturing tolerance. * Delivery Length tolerance is ± 5% Length more than normal as per customer request.
TABLE 16 - 3.8 / 6.6 KV (E) HT XLPE THREE CORE COPPER CONDUCTOR CABLES
UNARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal Sizeof
Conductor
Nominal Thicknessof XLPE
Insulation
Nominal Thickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
MinimumThicknessof InnerSheath
Nominal Dimension
of Strip
MinimumThickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
Nominal Dimension
of Round Wire
MinimumThickness
of PVC Outer
Sheath
Approx.Overall
Diameterof
Cable
Approx.Weight of
Cable.
In Ground at
30° C.
In Duct at 30° C.
In Air at 40° C.
*Normal DeliveryLength.
Sq.mm.
35
50
70
95
120
150
185
240
300
400
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
3.0
3.3
0.4
0.5
0.5
0.5
0.5
0.6
0.6
0.7
0.7
0.7
2.2
2.4
2.6
2.6
2.8
2.8
3.0
3.2
3.4
3.8
2255
2852
3654
4553
5505
6552
7854
9801
11902
15405
40.0
42.5
47.5
50.5
55.0
58.0
65.0
67.0
73.5
82.5
2855
3400
4260
5210
6210
7260
8610
10560
12760
16410
2.00
2.00
2.00
2.50
2.50
2.50
2.50
3.15
3.15
3.15
1.72
1.88
1.88
2.04
2.20
2.20
2.36
2.52
2.68
3.00
43.0
45.5
49.5
54.0
58.5
61.0
66.0
73.5
79.0
89.5
3460
4150
5010
6500
7600
8700
10160
13060
15450
20660
145
170
210
250
280
310
350
400
445
500
125
150
180
215
240
270
305
350
390
440
165
195
240
295
335
380
430
500
510
650
500
500
500
500
500
500
500
500
500
250
mm mm mm mm mm mm mm mm mm Amps. Amps. Amps. Mtrs.Kg/Km Kg/Km Kg/Km
40.4
43.2
47.5
51.3
55.5
58.3
63.5
68.3
74.4
83.5
1.72
1.72
1.88
1.88
2.04
2.20
2.20
2.36
2.52
2.84
Medium Voltage Cables
STEEL STRIP ARMOURED CABLE STEEL ROUND WIRE ARMOURED CABLE
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
mm
mm
Medium Voltage Cables 57
TABLE 17 - 6.35 / 11 KV (E) HT XLPE THREE CORE ALUMINIUM CONDUCTOR CABLES
“ " THREE CORE ALUMINIUM CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES CONFORMING TO IS: 7098 PART-2/1985:TIRUPATI PLASTOMATICS
UNARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal Sizeof
Conductor
Nominal Thicknessof XLPE
Insulation
Nominal Thickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
MinimumThicknessof InnerSheath
Nominal Dimension
of Strip
MinimumThickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
Nominal Dimension
of Round Wire
MinimumThickness
of PVC Outer
Sheath
Approx.Overall
Diameterof
Cable
Approx.Weight of
Cable.
In Ground at
30° C.
In Duct at 30° C.
In Air at 40° C.
*Normal DeliveryLength.
Sq.mm.
35
50
70
95
120
150
185
240
300
400
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
0.5
0.5
0.5
0.6
0.6
0.6
0.7
0.7
0.7
0.7
2.4
2.6
2.6
2.8
2.8
3.0
3.2
3.4
3.6
3.8
43.7
46.2
50.3
54.7
58.3
61.2
66.4
71.8
76.7
83.2
1952
2254
2655
3153
3602
4105
4853
5702
6655
8104
1.72
1.72
1.88
1.88
2.04
2.20
2.20
2.36
2.52
2.84
44.2
46.7
50.6
54.8
58.2
61.3
66.5
71.7
76.6
83.2
2252
2853
3305
3854
4402
4901
5653
6604
7602
9105
2.00
2.50
2.50
2.50
2.50
2.50
3.15
3.15
3.15
4.00
1.88
2.04
2.04
2.20
2.20
2.36
2.52
2.68
2.84
3.00
45.7
49.8
53.2
58.3
61.8
64.2
71.4
76.3
81.5
90.3
3255
4003
4602
5254
5853
6453
8103
9255
10403
13454
115
130
160
190
220
245
275
315
355
400
97
115
140
165
190
210
240
275
310
350
125
150
190
230
260
295
335
395
450
520
500
500
500
500
500
500
500
500
250
250
mm mm mm mm mm mm mm mm mm Amps. Amps. Amps. Mtrs.Kg/Km Kg/Km Kg/Km
“ " THREE CORE COPPER CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES CONFORMING TO IS: 7098 PART-2/1985:TIRUPATI PLASTOMATICS
The above data is approximate and subject to manufacturing tolerance. * Delivery Length tolerance is ± 5% Length more than normal as per customer request.
TABLE 18 - 6.35 / 11 KV (E) HT XLPE THREE CORE COPPER CONDUCTOR CABLES
UNARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal Sizeof
Conductor
Nominal Thicknessof XLPE
Insulation
Nominal Thickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
MinimumThicknessof InnerSheath
Nominal Dimension
of Strip
MinimumThickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
Nominal Dimension
of Round Wire
MinimumThickness
of PVC Outer
Sheath
Approx.Overall
Diameterof
Cable
Approx.Weight of
Cable.
In Ground at
30° C.
In Duct at 30° C.
In Air at 40° C.
*Normal DeliveryLength.
Sq.mm.
35
50
70
95
120
150
185
240
300
400
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
0.5
0.5
0.5
0.6
0.6
0.6
0.7
0.7
0.7
0.7
2.4
2.6
2.6
2.8
2.8
3.0
3.2
3.4
3.6
3.8
2602
3155
3953
4951
5854
6905
8303
10202
12202
15554
44.2
46.7
50.3
54.1
58.8
61.2
66.3
71.1
76.4
83.7
3152
3755
4601
5603
6654
7655
9103
11052
13154
16555
2.00
2.50
2.50
2.50
2.50
2.50
3.15
3.15
3.15
4.00
1.88
2.04
2.04
2.20
2.20
2.36
2.52
2.68
2.84
3.00
45.2
49.3
53.6
58.2
61.7
64.8
71.2
76.3
81.4
90.2
3905
4953
5904
7002
8103
9255
11553
13704
15955
20903
145
170
210
250
280
310
350
400
445
500
125
150
180
215
240
270
305
350
390
440
165
195
240
295
335
380
430
500
510
650
500
500
500
500
500
500
500
250
250
250
mm mm mm mm mm mm mm mm mm Amps. Amps. Amps. Mtrs.Kg/Km Kg/Km Kg/Km
43.7
46.2
50.8
54.3
58.4
61.2
66.4
71.2
76.7
83.8
1.72
1.88
1.88
2.04
2.20
2.20
2.36
2.52
2.68
2.84
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
STEEL STRIP ARMOURED CABLE STEEL ROUND WIRE ARMOURED CABLE
STEEL STRIP ARMOURED CABLE STEEL ROUND WIRE ARMOURED CABLE
mm
mm
58
TABLE 19 - 11 / 11 KV (UE) HT XLPE THREE CORE ALUMINIUM CONDUCTOR CABLES
“ " THREE CORE ALUMINIUM CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES CONFORMING TO IS: 7098 PART-2/1985:TIRUPATI PLASTOMATICS
UNARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal Sizeof
Conductor
Nominal Thicknessof XLPE
Insulation
Nominal Thickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
MinimumThicknessof InnerSheath
Nominal Dimension
of Strip
MinimumThickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
Nominal Dimension
of Round Wire
MinimumThickness
of PVC Outer
Sheath
Approx.Overall
Diameterof
Cable
Approx.Weight of
Cable.
In Ground at
30° C.
In Duct at 30° C.
In Air at 40° C.
*Normal DeliveryLength.
Sq.mm.
70
95
120
150
185
240
300
400
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
3.0
3.2
3.2
3.4
3.4
3.6
3.8
4.0
59.8
63.2
67.3
70.7
74.8
80.1
85.2
92.4
3552
4104
4653
5205
5902
6853
7855
9404
2.20
2.36
2.36
2.52
2.68
2.84
3.00
3.00
59.7
63.2
67.4
70.2
74.1
80.2
85.3
92.5
4305
4903
5504
6105
6952
7903
8954
10505
2.50
3.15
3.15
3.15
3.15
3.15
4.00
4.00
2.36
2.52
2.52
2.68
2.84
3.00
3.00
3.00
63.2
68.7
72.2
75.4
80.3
85.5
91.2
98.4
5905
7253
8004
8653
9652
10851
13254
15202
160
190
220
245
275
315
355
400
140
165
190
210
240
275
310
350
190
230
260
295
335
395
450
520
500
500
500
500
250
250
250
500
mm mm mm mm mm mm mm mm mm Amps. Amps. Amps. Mtrs.Kg/Km Kg/Km Kg/Km
“ " THREE CORE COPPER CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES CONFORMING TO IS: 7098 PART-2/1985:TIRUPATI PLASTOMATICS
The above data is approximate and subject to manufacturing tolerance. * Delivery Length tolerance is ± 5% Length more than normal as per customer request.
TABLE 20 - 11 / 11 KV (UE) HT XLPE THREE CORE COPPER CONDUCTOR CABLES
UNARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal Sizeof
Conductor
Nominal Thicknessof XLPE
Insulation
Nominal Thickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
MinimumThicknessof InnerSheath
Nominal Dimension
of Strip
MinimumThickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
Nominal Dimension
of Round Wire
MinimumThickness
of PVC Outer
Sheath
Approx.Overall
Diameterof
Cable
Approx.Weight of
Cable.
In Ground at
30° C.
In Duct at 30° C.
In Air at 40° C.
*Normal DeliveryLength.
Sq.mm.
70
95
120
150
185
240
300
400
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
3.0
3.2
3.2
3.4
3.4
3.6
3.8
4.0
59.7
63.2
67.3
70.8
74.1
80.2
85.4
92.3
4905
5903
6904
8002
9301
11304
13405
16853
2.20
2.36
2.36
2.52
2.68
2.84
3.00
3.00
59.2
63.4
67.3
70.1
74.2
80.4
85.3
92.4
5605
6702
7754
8902
10303
12355
14504
17952
2.50
3.15
3.15
3.15
3.15
3.15
4.00
4.00
2.36
2.52
2.52
2.68
2.84
3.00
3.00
3.00
63.2
68.3
72.4
75.5
80.1
85.2
91.4
98.5
7155
9003
10254
11452
13105
15353
18852
22654
210
250
280
310
350
400
445
500
180
215
240
270
305
350
390
440
240
295
335
380
430
500
570
650
500
500
500
250
250
250
250
500
mm mm mm mm mm mm mm mm mm Amps. Amps. Amps. Mtrs.Kg/Km Kg/Km Kg/Km
Medium Voltage Cables
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
STEEL STRIP ARMOURED CABLE STEEL ROUND WIRE ARMOURED CABLE
STEEL STRIP ARMOURED CABLE STEEL ROUND WIRE ARMOURED CABLE
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
mm
mm
Medium Voltage Cables 59
TABLE 21 - 12.7 / 22 KV (E) HT XLPE THREE CORE ALUMINIUM CONDUCTOR CABLES
“ " THREE CORE ALUMINIUM CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES CONFORMING TO IS: 7098 PART-2/1985:TIRUPATI PLASTOMATICS
UNARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal Sizeof
Conductor
Nominal Thicknessof XLPE
Insulation
Nominal Thickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
MinimumThicknessof InnerSheath
Nominal Dimension
of Strip
MinimumThickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
Nominal Dimension
of Round Wire
MinimumThickness
of PVC Outer
Sheath
Approx.Overall
Diameterof
Cable
Approx.Weight of
Cable.
In Ground at
30° C.
In Duct at 30° C.
In Air at 40° C.
*Normal DeliveryLength.
Sq.mm.
95
120
150
185
240
300
400
6.0
6.0
6.0
6.0
6.0
6.0
6.0
0.7
0.7
0.7
0.7
0.7
0.7
0.7
3.2
3.4
3.4
3.6
3.8
4.0
4.0
66.2
70.1
72.4
77.2
82.3
87.2
94.8
4455
5052
5554
6301
7303
8305
9852
2.36
2.52
2.68
2.68
2.84
3.00
3.00
66.2
70.1
72.7
77.6
82.8
87.2
94.3
5305
5902
6503
7251
8304
9355
10952
3.15
3.15
3.15
3.15
4.00
4.00
4.00
2.52
2.68
2.68
2.84
3.00
3.00
3.00
71.2
75.3
77.4
82.2
89.1
93.4
100.5
7755
8502
9204
10151
12602
13854
15803
190
215
240
270
310
350
395
170
190
215
240
275
310
355
230
265
300
340
400
455
530
500
250
250
250
250
250
500
mm mm mm mm mm mm mm mm mm Amps. Amps. Amps. Mtrs.Kg/Km Kg/Km Kg/Km
“ " THREE CORE COPPER CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES CONFORMING TO IS: 7098 PART-2/1985:TIRUPATI PLASTOMATICS
The above data is approximate and subject to manufacturing tolerance. * Delivery Length tolerance is ± 5% Length more than normal as per customer request.
TABLE 22 - 12.7 / 22 KV (E) HT XLPE THREE CORE COPPER CONDUCTOR CABLES
UNARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal Sizeof
Conductor
Nominal Thicknessof XLPE
Insulation
Nominal Thickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
MinimumThicknessof InnerSheath
Nominal Dimension
of Strip
MinimumThickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
Nominal Dimension
of Round Wire
MinimumThickness
of PVC Outer
Sheath
Approx.Overall
Diameterof
Cable
Approx.Weight of
Cable.
In Ground at
30° C.
In Duct at 30° C.
In Air at 40° C.
*Normal DeliveryLength.
Sq.mm.
95
120
150
185
240
300
400
6.0
6.0
6.0
6.0
6.0
6.0
6.0
0.7
0.7
0.7
0.7
0.7
0.7
0.7
3.2
3.4
3.4
3.6
3.8
4.0
4.0
66.2
70.1
72.7
77.8
82.2
87.1
94.6
6205
7302
8303
9754
11752
13901
17255
2.36
2.52
2.68
2.68
2.84
3.00
3.00
66.2
70.1
72.3
77.2
82.8
87.7
94.2
7052
8155
9302
10704
12752
14951
18403
3.15
3.15
3.15
3.15
4.00
4.00
4.00
2.52
2.68
2.68
2.84
3.00
3.00
3.00
71.2
75.1
77.8
82.3
89.2
93.7
100.2
9505
10752
11954
13605
17053
19404
23252
245
275
305
345
395
440
495
215
245
275
305
350
390
440
300
340
385
435
510
580
660
500
250
250
250
250
200
500
mm mm mm mm mm mm mm mm mm Amps. Amps. Amps. Mtrs.Kg/Km Kg/Km Kg/Km
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
STEEL STRIP ARMOURED CABLE STEEL ROUND WIRE ARMOURED CABLE
STEEL STRIP ARMOURED CABLE STEEL ROUND WIRE ARMOURED CABLE
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
mm
mm
60
TABLE 23 - 19 / 33 KV (E) HT XLPE THREE CORE ALUMINIUM CONDUCTOR CABLES
“ " THREE CORE ALUMINIUM CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES CONFORMING TO IS: 7098 PART-2/1985:TIRUPATI PLASTOMATICS
UNARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal Sizeof
Conductor
Nominal Thicknessof XLPE
Insulation
Nominal Thickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
MinimumThicknessof InnerSheath
Nominal Dimension
of Strip
MinimumThickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
Nominal Dimension
of Round Wire
MinimumThickness
of PVC Outer
Sheath
Approx.Overall
Diameterof
Cable
Approx.Weight of
Cable.
In Ground at
30° C.
In Duct at 30° C.
In Air at 40° C.
*Normal DeliveryLength.
Sq.mm.
95
120
150
185
240
300
400
8.8
8.8
8.8
8.8
8.8
8.8
8.8
0.7
0.7
0.7
0.7
0.7
0.7
0.7
3.6
3.8
4.0
4.0
4.0
4.0
4.0
79.1
83.2
86.3
90.7
95.8
100.2
106.3
6055
6752
7403
8154
9155
10201
11802
2.84
2.84
3.00
3.00
3.00
3.00
3.00
79.2
83.4
86.8
90.2
95.1
100.2
106.3
7105
7752
8403
9252
10304
11355
13102
3.15
4.00
4.00
4.00
4.00
4.00
4.00
3.0
3.0
3.0
3.0
3.0
3.0
3.0
84.1
89.3
92.2
96.4
101.2
105.1
112.3
10055
12102
12803
13904
15152
16455
18552
190
215
240
270
310
350
395
170
190
215
240
275
310
355
230
265
300
340
400
455
530
500
250
250
250
250
250
500
mm mm mm mm mm mm mm mm mm Amps. Amps. Amps. Mtrs.Kg/Km Kg/Km Kg/Km
“ " THREE CORE COPPER CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES CONFORMING TO IS: 7098 PART-2/1985:TIRUPATI PLASTOMATICS
The above data is approximate and subject to manufacturing tolerance. * Delivery Length tolerance is ± 5% Length more than normal as per customer request.
TABLE 24 - 19 / 33 KV (E) HT XLPE THREE CORE COPPER CONDUCTOR CABLES
UNARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal Sizeof
Conductor
Nominal Thicknessof XLPE
Insulation
Nominal Thickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
MinimumThicknessof InnerSheath
Nominal Dimension
of Strip
MinimumThickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
Nominal Dimension
of Round Wire
MinimumThickness
of PVC Outer
Sheath
Approx.Overall
Diameterof
Cable
Approx.Weight of
Cable.
In Ground at
30° C.
In Duct at 30° C.
In Air at 40° C.
*Normal DeliveryLength.
Sq.mm.
95
120
150
185
240
300
400
8.8
8.8
8.8
8.8
8.8
8.8
8.8
0.7
0.7
0.7
0.7
0.7
0.7
0.7
3.6
3.8
4.0
4.0
4.0
4.0
4.0
79.5
83.3
86.8
90.7
95.6
100.4
106.8
7857
9008
10153
11604
13603
15755
19254
2.84
2.84
3.00
3.00
3.00
3.00
3.00
79.2
83.4
86.8
90.3
95.7
100.2
106.3
8904
1005
11202
12705
14753
16954
20555
3.15
4.00
4.00
4.00
4.00
4.00
4.00
3.0
3.0
3.0
3.0
3.0
3.0
3.0
84.4
89.8
92.2
96.7
101.3
105.7
112.8
11805
14302
15604
17301
19605
22003
26002
245
275
305
345
395
440
495
215
245
275
305
350
390
440
300
340
385
435
510
580
660
250
250
250
250
250
200
200
mm mm mm mm mm mm mm mm mm Amps. Amps. Amps. Mtrs.Kg/Km Kg/Km Kg/Km
Medium Voltage Cables
STEEL STRIP ARMOURED CABLE STEEL ROUND WIRE ARMOURED CABLE
STEEL STRIP ARMOURED CABLE STEEL ROUND WIRE ARMOURED CABLE
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
mm
mm
Medium Voltage Cables 61
TABLE 25 - 33 / 33 KV (UE) HT XLPE THREE CORE ALUMINIUM CONDUCTOR CABLES
“ " THREE CORE ALUMINIUM CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES CONFORMING TO IS: 7098 PART-2/1985:TIRUPATI PLASTOMATICS
UNARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal Sizeof
Conductor
Nominal Thicknessof XLPE
Insulation
Nominal Thickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
MinimumThicknessof InnerSheath
Nominal Dimension
of Strip
MinimumThickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
Nominal Dimension
of Round Wire
MinimumThickness
of PVC Outer
Sheath
Approx.Overall
Diameterof
Cable
Approx.Weight of
Cable.
In Ground at
30° C.
In Duct at 30° C.
In Air at 40° C.
*Normal DeliveryLength.
Sq.mm.
120
150
185
240
300
400
9.5
9.5
9.5
9.5
9.5
9.5
0.7
0.7
0.7
0.7
0.7
0.7
4.0
4.0
4.0
4.0
4.0
4.0
88.2
91.4
95.7
100.3
105.2
111.1
7605
8152
8954
1005
11053
12752
3.0
3.0
3.0
3.0
3.0
3.0
88.8
91.2
95.7
100.1
105.3
111.2
8655
9253
10104
11205
12303
14104
4.0
4.0
4.0
4.0
4.0
4.0
3.0
3.0
3.0
3.0
3.0
3.0
94.2
97.3
101.5
106.3
110.2
117.4
12705
13453
14552
15853
17304
19355
215
240
270
310
350
395
190
215
240
275
310
355
265
300
340
400
455
530
500
250
250
250
250
250
mm mm mm mm mm mm mm mm mm Amps. Amps. Amps. Mtrs.Kg/Km Kg/Km Kg/Km
“ " THREE CORE COPPER CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES CONFORMING TO IS: 7098 PART-2/1985:TIRUPATI PLASTOMATICS
The above data is approximate and subject to manufacturing tolerance. * Delivery Length tolerance is ± 5% Length more than normal as per customer request.
TABLE 26 - 33 / 33 KV (UE) HT XLPE THREE CORE COPPER CONDUCTOR CABLES
UNARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal Sizeof
Conductor
Nominal Thicknessof XLPE
Insulation
Nominal Thickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
MinimumThicknessof InnerSheath
Nominal Dimension
of Strip
MinimumThickness
of PVCOuter
Sheath
Approx. Overall
Diameterof
Cable
Approx. Weight
of Cable
Nominal Dimension
of Round Wire
MinimumThickness
of PVC Outer
Sheath
Approx.Overall
Diameterof
Cable
Approx.Weight of
Cable.
In Ground at
30° C.
In Duct at 30° C.
In Air at 40° C.
*Normal DeliveryLength.
Sq.mm.
120
150
185
240
300
400
9.5
9.5
9.5
9.5
9.5
9.5
0.7
0.7
0.7
0.7
0.7
0.7
4.0
4.0
4.0
4.0
4.0
4.0
88.8
91.2
95.6
100.7
105.3
111.1
9805
10952
12403
14454
16652
20153
3.0
3.0
3.0
3.0
3.0
3.0
88.1
91.2
95.7
100.3
105.2
111.8
10855
12003
13552
15654
17905
21553
4.0
4.0
4.0
4.0
4.0
4.0
3.0
3.0
3.0
3.0
3.0
3.0
94.2
97.4
101.5
106.2
110.8
117.2
14953
16254
18002
20305
22903
26752
275
305
345
395
440
495
245
275
305
350
390
440
340
385
435
510
580
660
500
250
250
250
200
200
mm mm mm mm mm mm mm mm mm Amps. Amps. Amps. Mtrs.Kg/Km Kg/Km Kg/Km
STEEL STRIP ARMOURED CABLE STEEL ROUND WIRE ARMOURED CABLE
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
STEEL STRIP ARMOURED CABLE STEEL ROUND WIRE ARMOURED CABLE
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
mm
mm
62
A. CABLE INSPECTION
Inspect every cable reet for damage before accepting the shipment. Be particularly alert for cable damage if :
1. A reel is lying flat on its side
2. Several reels are stacked
3. Other freight is stacked on a reel
4. Nails have been driven into reel flanges to secure shipping blocks
5. A reel flange is damaged
6. A cable covering is removed, stained or damaged
7. A cable end seal is removed or damaged. A reel has been dropped (hidden damage likely)
B. CABLE HANDLING & STORAGE
Damage to cables can occur due to the incorrect
handling to which the drums and cables may be subjected;
causing breakdown of the drum flanges and in exceptional
cases, movement of the drum barrel takes place. Once this
breakdown of the drum occurs, the cable damaged during
handling & storage can cause service failures when the
subject cable is put to use.
Thus the following is a list of Do's and Don'ts that should be
followed while handling and storing the cables before it is
put to use.
Do's Don'ts
When off loading reels from a truck, lower reel carefully using a hydraulic gate, hoist or forklift truck
If a fork lift is used, approach the reel from the flange side. Position the forks such that the reel is lifted by both reel flanges. Also Consideration should be given to, Traffic patterns during off-loading & damage during the time in storage
Cable reels should be stored on hard surfaces resting on the flanges edge (Flanges vertical). Align reels flange to flange and, if possible arrange so that first in is first out.
When using a hoist, install a mandrel through the reel arbor holes and attach a sling. Use spreader bar approximately 6 inches longer than the overall reel width placed between the sling ends just above the reel flanges.
Never drop reels. If reels must be rolled, roll in opposite direction of the cable wraps to keep cable from loosening on the reel.
Do not allow the lift forks to contact the cable. Care must be taken by the fork lift operator not to make sudden turns or stops.
Multiple reels stacked on top of each other ("Pancake" Storage is not recommended) for cble drums. The weight of the stack can total thousands of kgs. creating an enormous load on the bottom reel. Also, damage to the reel and/or cable will likely occur when the reel is flipped for transit. A concentration of stress on the reel flange may cause it to break and subsequently damage the cable.
This may lead to the bending of the reel flanges and mashing the cable
Handling, Storage and Laying of HT Cables.
Medium Voltage Cables
Medium Voltage Cables 63
C. PRE-INSTALLATION
D. INSTALLATION & LAYING
To ensure safety during cable Installation following shall be checked prior to installation.
1. The cable selected is proper for designed application.
2. The cable has not been damaged in transit or storage.
Review all applicable state and national codes to verify that the cable chosen is appropriate for the job. Also consult your local electricity authority. Next, you must identify any existing cable damage and prevent any further damaged from occurring. This is done through proper cable inspection, handling and storage.
Mechanical stresses during installation are generally more severe than those encountered while in service. Thus care should be taken as regards to the following while installation and laying of cables.
1. Tirupati Plastomatics recommend the laying and installation of cables as per IS : 1255/84.
2. Care shall be taken during laying to avoid sharp bending, and twisting.
3. Cable shall be un wound from the drum by lifting the drum on the center
4. Shaft supported both ends with sultable jacks/stands.
5. Under no circumstances the cable winding shall be lifted off a coil or drum lying flat at the flanges. This would cause serious twist and damages.
6. Suitable protection shall be provided to the cables against mechanical damages, it includes covers, pipes etc.
Single Core : 20 x D
Multicore : 15 x D
Where D= Diameter of cable in mm
2a) For Unarmoured Cable : P = 5D
Where P = Pulling Force
2b) For Armoured Cable : P = 9D
Where D = Diameter of cable in mm
2a) For Aluminium Conductors : 30 N / mm
2b) For Copper Conductor : 50 N / mm
E. RECOMMENDED MINIMUM BENDING RADIUS FOR HEAVY DUTY CABLES.
F. RECOMMENDED SAFE PULLING FORCE WITH STOCKINGS :
G. RECOMMENDED SAFE PULLING FORCE WHEN PULLED WITH PULLING EYE :
DO NOT ATTEMPT "COILING" OF CABLE ON THE GROUND
ON THE GROUND CABLE CAN BE FLAKED IN A FIGURE OF EIGHT FORMATION
64
EARTHED
In the initial years, the generators and transformers were having capacities of few MVA and hence fault current was also less. The star point or neutral point was solidly grounded and this is called earthed system.
In this system if an earth fault occurs on any of the phase, the voltages of other two healthy phases with respect to the earth remain the same.
UNEARTHED SYSTEM :
Today generators of 500 MVA capacity are in commercial use. More over several mega power stations are connected to grid. Due to this, the fault level has increased tremendously. In case of an earth fault, a heavy current flows in to the fault and this may damage the costly generators and power transformers.
To reduce the fault current, the star point is connected to the earth through a resistance or a reactance as under.
In this case if an earth fault occurs on R phase, the voltage of the faulty phase with respect to the earth (R) appears across across the current limiting resistance or reactance in the earth circuit of the star point and as a result the voltage of the star point which was at eath potential under normal conditions rises to VR. Due to this the voltages of other two healthy phases (B and Y) with respect to the earth rises by 1.7 times (Vector sum of VR and VB). If the insulation of these phases are not designed for these increased voltages they may develop earth fault. This is called Unearthed System.
N
VR
EARTH
R
Y
B
N
R
Y
B
Medium Voltage Cables
Medium Voltage Cables 65
Conversion Table
Multiply Multiplyby to obtain by to obtain
WEIGHT - Imperial
WEIGHTS - Metric
MISCELLANEOUS - Imperial
MISCELLANEOUS - Metric
TEMPERATURE
Ounce ________________ 28.3495 gramsPounds (Av) ___________ 453.59 gramsPounds (Av) ___________ 0.45359 kilogramsPounds (Av) ___________ 907.19 kilogramsTons (Long) ________ 1016.05 kilograms
Grams ________________ 0.03527 ouncesGrams ________________ 0.002205 poundsKilograms _____________ 35.274 ouncesKilograms _____________ 2.2046 poundsKilograms _____________ 0.001102 tons (short)Kilograms _____________ 0.0009842 tons (long)
Pounds per 1000 feet ___ 1.48816 kilograms per kilometer
Pounds per mile ______ 0.28185 kilograms per kilometers
Pounds per square inch_ 0.0007031 kilograms per
square millimeters
Pounds per square inch _ 0.07031 kilograms per
square centimeter
Feet per second ______ 18.288 meters per minute
Feet per second ______ 1.09728 kilometers per hour
Mils per hour _________1.60935 kilometers per hour
Ohms per mile__________ 0.62137 ohms per kilometerDecibels per 1000 feet ___ 3.28083 decibels per kilometerDecibels per mile ________ 0.62137 decibels per kilometerDecibels ________________ 0.1153 nepers
Kilograms per kilometer __ 0.67197 pounds per 1000 feetKilograms per kilometer __ 3.54795 pounds per milekilograms per square millimeter _______________ 1422.34 pounds per squar inchKilograms per square centimeter ______________ 14.2234 pounds per square inchGrams per cubic cm _____ 0.03613 pounds per cubic inchMeters per minute _______ 0.05468 feet per secondKilometer per hour ______ 0.91134 feet per secondKilometer per hour _______ 0.62137 miles per hour Ohms per kilometer______ 0.3048 ohms per 1000 f eetOhms per kilometer ______ 1.6093 ohms per mileDecibels per kilometer ____ 0.3048 decibels per 1000 feetDecibels per kilometer ____ 1.6093 decibels per mile
o o oFahrenheit ___________ 5/9 ( F)-32 Celsiuso o oCelsius ______________ 9/5 ( C)+32 Fahrenheit
LENGTH - Imperial
LENGTH - Imperial
AREA - Imperial
AREA - Metric
VOLUME - Imperial
VOLUME - U.S.
VOLUME - Metric
Mils __________________ 0.001 inchesMils __________________ 0.0254 millimetersInches ________________ 1000 milsInches ________________ 25.40 millimetersInches ________________ 2.54 centimetersFeet __________________ 30.48 centimetersFeet __________________ 0.3048 metersFeet (thousand of) _______ 0.3048 kilometersYards _________________ 0.9144 metersMils ___________________ 1.6093 kilometers
Millimeters ______________ 39.37 milsMillimeters ______________ 0.03937 inchesCentimeters _____________ 0.3937 inchesMeters _________________ 39.37 inchesCentimeters _____________ 0.032808 feetMeters _________________ 39.37 inchesMeters _________________ 3.2808 feetMeters _________________ 1.0936 yardsKilometers ______________ 3280.83 feetKilometers ______________ 0.62137 mils
Square mils ______________ 1.2732 circular milsSquare mils ______________ 0.000001 square inchesCircular mils _____________ 0.7854 square milsCircular mils _____________ 0.0000007854 square inchesCircular mils _____________ 0.00050657 square millimetersSquare inches____________ 1000000 square milsSquare inches ___________ 1273240 Circular milsSquare inches ___________ 645.16 square millimeters Square inches ___________ 6.4516 square centimeters Square inches ___________ 0.09290 square metersSquare inches ___________ 0.8361 square meters
Square millimeters ________ 1973.52 circular milsSquare millimeters ________ 0.00155 square inchesSquare centimeters _______ 0.155 square inchesSquare meters ___________ 10.7638 square feetSquare meters ___________ 1.19599 square yards
Cubic inches ____________ 16.38716 cubic metersCubic feet ______________ 0.028317 cubic meters
Quarts (liquid) ____________ 0.9463 cubic centimetersGallaons ________________ 3.7854 cubic meters
Cubic centimeters ________ 0.06102 cubic inchesCubic meters ____________ 35.3145 cubic feetLiters __________________ 1.05668 quarts (Liquid U.S.) Liters __________________ 0.26417 gallons (U.S.)
CERTIFICATES
CERTIFICATES
CERTIFICATES
CERTIFICATES
CLIENTSCLIENTSACCROSS GLOBE ACCROSS GLOBE
UAE
Botswana
Sri Lanka
Nepal
Butan
MyanmarMyanmar
Ghana
South Africa
Angola
Cango
Uganda
Ethopia
Mauritius
Afganistan
Moza
mbiq
ue
Moza
mbiq
ue
MalaviMalavi
KenyaKenya
India India
Tanzania Tanzania
ZambiaZambia
Printe
d b
y : H
are
shw
ar
Printe
rs #
9829066769
B-141 (A), Road No. 9-D, V.K.I. Area, Jaipur-302013,Rajasthan, INDIA
Phone :
Fax :
Email :
Web :
+91 141 2332902, 2331030, 2330305, 2330427
+91 141 2331808, 2260073
www.tirupatiplastomatics.com