50
Technical Training 2007 Technical Training 2007 TECHNICAL TRAINING TECHNICAL TRAINING 2007 2007

TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Embed Size (px)

Citation preview

Page 1: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

TECHNICAL TRAINING TECHNICAL TRAINING

20072007

Page 2: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

SMART COMMANDERSMART COMMANDER

Page 3: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

System Requirements

• CPU : 800MHz and aboveCPU : 800MHz and above

• Memory : 256MB RAM or HigherMemory : 256MB RAM or Higher

• Hard Drive : 4G or higher for hard disk spaceHard Drive : 4G or higher for hard disk space

• OS : Windows 2000/XPOS : Windows 2000/XP

• Resolution : 1024 x 768 Resolution : 1024 x 768

• Monitor : Larger than 15 inch, & 17 inch is Monitor : Larger than 15 inch, & 17 inch is recommendedrecommended

• Serial port & USB port availableSerial port & USB port available

Page 4: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

User Login• Install the driver of encrypt USB keyInstall the driver of encrypt USB key

• Driver file: SP1730RC9.zipDriver file: SP1730RC9.zip

• Default user name: adminDefault user name: admin

• Password: mcquaymds (can be amend)Password: mcquaymds (can be amend)

Page 5: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

Menu Introduction

File MenuFile Menu

• ““Exit” onlyExit” only

Function MenuFunction Menu

• Initiating: Hardware changesInitiating: Hardware changes

• Error History: to record the faults in the system Error History: to record the faults in the system

• User Manager: to manage the user name & User Manager: to manage the user name & passwordpassword

• Parameter Setting: to set parameter of the Parameter Setting: to set parameter of the systemsystem

• Prompts for the units runningPrompts for the units running

Page 6: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

ID Monitor

From the 1From the 1stst tab on the left, user can perform tab on the left, user can perform related operation to the ID connected to ODrelated operation to the ID connected to OD

1. Select OD follow by ID 1. Select OD follow by ID

2. Select ID operation2. Select ID operation

3. Adjust ID temperature 3. Adjust ID temperature

4. Turn ON / OFF4. Turn ON / OFF

5. Click “Confirm” to achieve operation 5. Click “Confirm” to achieve operation

6. Double click to see Real Time Fault 6. Double click to see Real Time Fault

Page 7: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

Grouping & Timer

1. Click 1. Click

2. Select Default group number 2. Select Default group number

3. Select ID number3. Select ID number

4. Click to select the customized group 4. Click to select the customized group number (Max member in a customized is number (Max member in a customized is 4848))

5. Add the selected ID to the customized group5. Add the selected ID to the customized group

6. Edit the customized group name & ID name6. Edit the customized group name & ID name

7. Click “Edit” button to enter Timer setting7. Click “Edit” button to enter Timer setting

8. Timer Mode Setting8. Timer Mode Setting

Page 8: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

System Monitor

From the 2From the 2ndnd tab on the left, user can control the ID tab on the left, user can control the ID & OD & OD

1. Double click the ID icon. A window will pop up 1. Double click the ID icon. A window will pop up

2. Right click the ID icon, user can lock the ID2. Right click the ID icon, user can lock the ID

3. Indication of model icon 3. Indication of model icon

Page 9: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

Circuit & Server Monitor

Please connect Please connect ENCRPT USB KEYENCRPT USB KEY of PC, then of PC, then connect to Smart Commander software for connect to Smart Commander software for debugging.debugging.

Using service Using service ENCRPT USB KEYENCRPT USB KEY will not display will not display Circuit Monitor & Server Monitor. Please use Circuit Monitor & Server Monitor. Please use customer software after debugging. customer software after debugging.

Customer software will only display ID control & Customer software will only display ID control & system monitor interface.system monitor interface.

Page 10: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

Circuit Monitor

Used to monitor ALL parameter of ID & ODUsed to monitor ALL parameter of ID & OD

• Observe ALL parameter of OD through collect Observe ALL parameter of OD through collect address codeaddress code

Page 11: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

Circuit Monitor

• OD parameterOD parameter Single, Master, Slave

Cooling, Heating, Defrost, StopDisplay OD program

OD output capacity (Include Slave)OD output capacity (Include Slave)

TTsh_outsh_out: OD superheat: OD superheatDigital compressor output %Digital compressor output %

OD Fan: Stop, Low, HighOD Fan: Stop, Low, HighHS: High Pressure (bar)HS: High Pressure (bar) LS: Low Pressure (bar)LS: Low Pressure (bar)

Heating electronic expansion valve

Subcool electronic expansion valve

Bypass way valeHigh pressure / Low pressure switch

Page 12: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

Circuit Monitor

• OD parameterOD parameter

TH1: Discharge air temp

TH2: The 1st condenser entering temp

TH3: The 1st condenser middle temp

TH4: The 2nd condenser entering temp

TH5: The 2nd condenser middle temp

TH6: Entering water temp

TH7: Heating water temp

TH8: Outdoor temp

TH9: Temp before subcool

TH10: Temp after subcool

TH11: Subcool loop exit temp

TH12: Suction temp

Sensor is Sensor is unavailableunavailable

Page 13: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

OD System Theory Diagram

OD address numberOD address number RedRed Line: Heating Line: HeatingGreenGreen Line: Cooling / Dehumidify Line: Cooling / DehumidifyBlack LineBlack Line: Stop: Stop

Sensor position is hint positionSensor position is hint position

Page 14: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

ID System Diagram Parameters

Click “Up” or “Down”, Click “Up” or “Down”, ID address number will ID address number will move up or downmove up or down

Click “Back Page” Click “Back Page” or “Next or “Next Page”, the page will Page”, the page will turn up or downturn up or down

Address number of IDAddress number of ID

Page 15: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

ID System Diagram Parameters

Click “Ctrl” to set IDClick “Ctrl” to set ID• Choose optional parameters to control single unit Choose optional parameters to control single unit • Optional mode: Stop, Cooling, Heating, Dry, FanOptional mode: Stop, Cooling, Heating, Dry, Fan• Fan Speed: Low, Medium, High & AutoFan Speed: Low, Medium, High & Auto• Assistant function: Aux heater, Swing & LockAssistant function: Aux heater, Swing & Lock

Page 16: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

Circuit Monitor

1.1. Modify OD parameters settingModify OD parameters setting

• Defrost curve A, B point. Default setting A is Defrost curve A, B point. Default setting A is -6 -6 °C, B is -24 °C°C, B is -24 °C

• Defrost Finish Temp: defrost stop when TH9 Defrost Finish Temp: defrost stop when TH9 achieve this tempachieve this temp

• Defrost Interval Time: defrost stop when Defrost Interval Time: defrost stop when compressor runs for this interval time compressor runs for this interval time

• TscA1, TscA2, TscT1, TscT2, TscT3TscA1, TscA2, TscT1, TscT2, TscT3When TH9 ≤ TscA1, subcool is TscT1When TH9 ≤ TscA1, subcool is TscT1

When TscA1 < TH9 ≤ TscA2, subcool is TscT2When TscA1 < TH9 ≤ TscA2, subcool is TscT2

When TH9 > TscA2, subcool is TscT3When TH9 > TscA2, subcool is TscT3

Page 17: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

Server Monitor• Used to obtain graph for parametersUsed to obtain graph for parameters

• Observe operationObserve operation

• Input or Output data from parameters file Input or Output data from parameters file

• Max. 5 parameters will be displayedMax. 5 parameters will be displayed

• 5 colours on top left indicate the parameters5 colours on top left indicate the parameters

Page 18: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

Server Monitor

Coordinate code name

Idiographic machine address code• 1 digit – OD• 2 digit – ID

Detail parameter name

Y- axis scale

Page 19: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

Server MonitorFunction Button:Function Button:

Page of display section

No. of pages

Go back to 1st page

Go back to previous page

Go to next page

Go to the last page

Go to parameter setting

Output data

Page 20: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

Wiring Connection

Page 21: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

Thank YouThank You

Page 22: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

Error History Record

Page 23: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

User Manager

To add user:• Key in user name• Key in password

1. Click “Add”

To modify:• Key in user name• Key in new password

1. Click “modify”

To delete user:• Select the user in the list

1. Click “Delete”

Page 24: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

Parameters Setting

System shut down 3 minutes when switching from “cool” to “heat” or vice versa

Min. running time before switching to another mode

Lock screen interval time - Unit in seconds- Unlock password: mcquaymds

Click this will shown as follow

Page 25: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

Parameters Setting

Page 26: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

Stage History

Page 27: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

ID Monitor

Page 28: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

ID Monitor

1. Choose number of the OD

2. Choose number of the ID

Page 29: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

ID Monitor

Multiple Control :

Single Control: Select a indoor unit only

Select many indoor units

Group Control : All the indoor units in the system

Page 30: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

ID Monitor

Select fan speed:(must select)

Select mode (must select)

Select assistant functions:

Page 31: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

ID Monitor

Click “ ” or “ ”, can adjust the set temperature

Select “ ” or “ ”, can turn on or close the units

Click “ ”, can send the order to the units

Page 32: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

ID MonitorThe error list window pops upThe error list window pops up::

Page 33: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

Group Set & Timer

Page 34: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

Group Set & Timer

Select OD

Click on the cell to select ID

Page 35: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

Customized Group Setting

Page 36: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

Customized Group Setting

After select the ID, click this button To delete

the selected ID, click this button

Page 37: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

Customized Group Setting

To edit customized group name:

1. Key in group name

2. Click “Refresh”

To edit ID name:

1. Key in ID name

2. Click “Refresh”

Page 38: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

Timer Setting

To add/delete the timer mode:

1. Key in name

2. Click “Add” or “Delete”

Select Timer Mode

To Add, Delete or Modify a task

Page 39: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

Timer SettingFirst mode: Select ON/OFF task First mode: Select ON/OFF task

Page 40: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

Timer SettingSecond mode: Select only “Second mode: Select only “ONON” or only “” or only “OFFOFF” ”

Page 41: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

Timer Mode Setting

1. Select ID

3. Click “Set”2. Select Mode

Page 42: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

System Monitor

Page 43: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

System Monitor

Page 44: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

System Monitor

Left click to select the locked function

Page 45: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

System Monitor

Page 46: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

Circuit Monitor

Page 47: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

Circuit Monitor

Defined defrost area

Defrost stop

2nd defrost start after 1st defrost

TH9 ≤ TscA1, subcool is TscT1TH9 ≤ TscA1, subcool is TscT1TscA1 < TH9 ≤ TscA2, subcool is TscT2TscA1 < TH9 ≤ TscA2, subcool is TscT2TH9 > TscA2, subcool is TscT3TH9 > TscA2, subcool is TscT3

Page 48: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

Server Monitor

Value of the parameters

Move the pointer to the desired point

Page 49: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

Server Monitor

Y1~Y5: parameter setting:

Tick to select ID parameter to be displayed

Max. value of Y-axis

Min. value of Y-axis

Major unit

Display the data of selected date

Display the data of real time

Click to display the graph

Input file

Page 50: TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB

Technical Training 2007Technical Training 2007

Server Monitor

Output Data: