NEW INSTRUCTIONAL BUILDING #2 ADDENDUM NO. 2
COMPTON COMMUNITY COLLEGE DISTRICT Page 1 of 3
Date: September 04, 2019
ADDENDUM NO. 2 To Project Bidding Documents for:
RFQ CCC-055
A#03-119458 Instructional Building #2 Compton Community College District
tBP Project. No. 20998.00
tBP/ARCHITECTURE 4611 Teller Avenue Newport Beach, CA 92660 949/673-0300
TO: PROSPECTIVE BIDDERS
This Addendum forms a part of the Contract Documents and modifies the original approved Bidding Drawings. Acknowledge receipt of this Addendum in space provided on the Bid Form. Failure to acknowledge may subject Bidder to disqualification.
CHANGES TO THE SPECIFICATIONS.
1. TABLE OF CONTENTS – Add SECTION 32 31 13 CHAIN-LINK FENCES ANDGATES to Division 32.
2. SECTION 32 31 13 CHAIN-LINK FENCES AND GATES – Add Division 32specification section.
CHANGES TO DRAWINGS
1. SHEET T-2 SHEET INDEX AND GENERAL INFORMAITON -a. Add to Electrical Drawings SHEET EQ-1.1 BUILDING “Q”
PARTIAL ELECTRICAL PLAN AND DETAILS.b. Add to Landscape Drawings SHEET L1.53 LANDSCAPE
CONSTRUCTION DETAILS.c. Remove from Architectural Drawings duplicated sheet 3.21
COLUMN DETAILS.
2. SHEET C1.2 GRADING PLAN - Incorporated Electrical Equipment Yard north ofexisting Building C.
3. SHEET L1.00 LANDSCAPE CONSTRUCTION SCHEDULE - Added M-01 for 8’HChain-link Fence and M-02 for 10’W x 8’H Chain-link double swing gate forSchedule.
4. SHEET L1.11 LANDSCAPE CONSTRUCTION PLAN - Incorporated location ofElectrical Equipment Yard north of existing Building C.
NEW INSTRUCTIONAL BUILDING #2 ADDENDUM NO. 2
COMPTON COMMUNITY COLLEGE DISTRICT Page 2 of 3
5. SHEET L1.31 LANDSCAPE CONSTRUCTION ENLARGED PLAN - Incorporated location of Electrical Equipment Yard north of the existing Building. Added paving finish P-01 for electrical equipment pad. Added chain-link gate and fence around electrical equipment.
6. SHEET L1.51 LANDSCAPE CONSTRUCTION DETAILS - Added Detail 11 for
8’H Chain-Link Fence at Electrical Yard and Detail 12 for 8’H x 10’W Double Swing Chain-Link Gate at Electrical Yard.
7. SHEET AS-2 ENLARGED SITE PLAN - Incorporated Electrical Equipment Yard
north of existing Building C.
8. SHEET E0-0.2 SINGLE LINE DIAGRAM - Revise Single Line Diagram.
9. SHEET E0-0.2A SINGLE LINE DIAGRAM - Revised Single Line Diagram
10. SHEET E0-0.6 ELECTRICAL ANCHORAGE DETAIL - Revise Detail 6 and add Detail 7.
11. SHEET ES-1.0 SITE ELECTRICAL DEMOLITION PLAN - Added Key Notes and
revised Overall Site Plan.
12. SHEET ES-1.1 OVERALL SITE ELECTRICAL PLAN - Added Key Notes and revised Overall Site Plan.
13. SHEET EQ-1.1 BUILING “Q” PARTIAL ELECTRICAL PLAN AND DETAILS -
Added Sheet. ---End of Addendum---
ATTACHMENTS
1. Full Size Documents 30” x 42” Drawings: (Total 12)
C1.2 GRADING PLAN L1.00 LANDSCAPE CONSTRUCIOTN SCHEDULE
L1.11 LANDSCAPE CONSTRUCTION PLAN L1.31 LANDSCAPE CONSTRUCTION ENLARGED PLAN L1.51 LANDSCAPE CONSTRUCTION DETAILS AS-2 ENLARGED SITE PLAN E0.2 SINGLE LINE DIAGRAM E0-0.2A SINGLE LINE DIAGRAM E0-0.6 ELECTRICAL ANCHORAGE DETAIL
ES-1.0 SITE ELECTRICAL DEMOLITION PLAN ES-1.1 OVERALL SITE ELECTRICAL PLAN
EQ-1.1 BUILING “Q” PARTIAL ELECTRICAL PLAN AND DETAILS -Added Sheet.
NEW INSTRUCTIONAL BUILDING #2 ADDENDUM NO. 2
COMPTON COMMUNITY COLLEGE DISTRICT Page 3 of 3
2. Specifications 323113 CHAIN-LINK FENCES AND GATES
Gary Moon tBP/Architecture CIVIL ENIGNEER FPL and Associates, Inc. 30 Corporate Park, Suite 401 Irvine, CA 92606 T (949) 252-1688 LANDSCAPE ARCHITECT AHBE Landscape Architects 617 West Seventh Street, Suite 304 Los Angeles, CA 90017 T (213) 694-3800 ELECTRICAL ENGINEER FBA Engineering 150 Paularino Avenue, Suite A120 Costa Mesa, CA 92626 T (949) 852-9992
Gary Moon tBP/Architecture CIVIL ENIGNEER FPL and Associates, Inc. 30 Corporate Park, Suite 401 Irvine, CA 92606 T (949) 252-1688 LANDSCAPE ARCHITECT AHBE Landscape Architects 617 West Seventh Street, Suite 304 Los Angeles, CA 90017 T (213) 694-3800 ELECTRICAL ENGINEER FBA Engineering 150 Paularino Avenue, Suite A120 Costa Mesa, CA 92626 T (949) 852-9992
HL1
HL2
DHM1 DPM1 DPP1
PP1A PP1B PP1C
DPP2 PP2A PP2B PP2C PSCI
INV.
EMH
EP1
EP2
PMR2
PAV1 PHL1 PMR1 PHL2
GF
F125
L1-1 L1-2 PMS1-2 PMS1-3
8
3
1
6
5
2
2
7
SPD
F90N F100 F100
F60
F225N F175N
F70N
F175
F60
F600F100
F100
F150
F175N F100
F100
F100
F400
F100
F1000
F100
F175N
F100
F100F100
F100
F150
F125
F125
F125
F400 F400
MMMMMM M
4
E0.0.5
4
E0.0.6
2
E0.0.6
3
E0.0.6
4
5
E0.0.6
3
E0.0.5
2
E0.0.6
PMH-5
PMS-1
PMH-6
PMH-7
PMH-8
600A3P
600A3P
100A3P
100A3P
100A3P
100A3P
1 2 3 4
SPARE
FUTURE STUDENTSERVICE BLDG.
INSTRUCTIONALBLDG. #1
TO CAMPUS MAIN SWITCHGEAR
CIRCUIT BREAKER CB-1
PM
S1-1
TO CIRCUIT BREAKER CB-2
OF CAMPUS MAIN SWITCHGEAR
THROUGH PMS-2 AND PMS-3
ELEVATOR
GROUND BUS
LEVEL 01
LEVEL 02
ROOF
CBP2
TM1
1 2 4 5 6 7
MAIN BUS 1000 AMPERE
UPS OUTPUT VOLTAGE:
UPS FULL RATED LOAD CONTINOUS
UNINTERRUPTIBLE POWER SUPPLY "UPS"
UPS INPUT VOLTAGE:
1000A3P
MAINCB
100%RATED
8 9 10 11
T1
TP2
175A3P
9A
90A3P
225A3P
100A3P
225A3P
175A3P
60A3P
112.5kVAXR BATTERY ENCLOSURES
UPS40kW
150kVA45kVA
1#3/0GRD.-1 1/4"C.1#4GRD.-1 1/4"C.
1#2/0GRD.-1 1/4"C.
208/120V, 3 PHASE, 4 WIRE
208V, 3 PHASE,43 WIRE
30KW @ 1.0 POWER FACTOR
27KW @ 0.9 POWER FACTOR
RUNNING TIME ON BATTERY CAPACITYNOT LESS THAN 30 MINUTES CONTINUOUS
MAIN DISTRIBUTION SWITCHBOARD "MDBH"
1000 AMPERE - 277/480V, 3PH, 4W
600AS
4.16KV480/277V. 3PH, 4W750KVA TRANSFORMER "T-IB2"FORCED VENTILATIONOUTDOOR, WEATHERPROOF
FEEDER SCHEDULE
F1600/DN 5 5" 5 500MCM 4/0F1200/DN 4 4" 5 350MCM 3/0F800/DN 3 5" 5 350MCM 1/0F600/DN 2 4" 5 350MCM 1F400/DN 2 3" 5 3/0 2F300/DN 1 4" 5 350MCM 2F225/DN 1 3" 5 4/0 4F150/DN 1 2 1/2" 5 1/0 4F125/DN 1 2 1/2" 5 1/0 6F100/DN 1 2" 3/1 1/2/0 8F60/DN 1 1 1/2" 3/1 4/1 10
F800/NU 3 4" 3 350MCM 2/0F700/NU 2 4" 3 500MCM 1/0F600/NU 2 4" 3 500MCM 1/0F500/NU 2 4" 3 350MCM 1/0F400/NU 2 3" 3 4/0 2F350/NU - - - - -
F4000/U 15 4" 4 500MCM 500MCMF3000/U 11 4" 4 500MCM 500MCMF2500/U 9 4" 4 500MCM 500MCMF2000/U 8 4" 4 500MCM 350MCMF1600/U 6 4" 4 500MCM 250MCMF1200/U 4 4" 4 500MCM 250MCMF1000/U 3 4" 4 500MCM 4/0F900/U 3 4" 4 500MCM 4/0F800/U 3 4" 4 350MCM 2/0F700/U 2 4" 4 500MCM 2/0F600/U 2 4" 4 500MCM 2/0F500/U 2 4" 4 350MCM 1/0F400/U 2 3" 4 4/0 2F350/U - - - - -
F800/N 3 3" 3 350MCM 1/0F700/N 2 4" 3 500MCM 1/0F600/N 2 3" 3 350MCM 1F500/N 2 2 1/2" 3 250MCM 2F400/N 2 2" 3 3/0 2F350/N 1 4" 3 500MCM 2F300/N 1 3" 3 350MCM 4F275/N 1 3" 3 350MCM 4F250/N 1 2 1/2" 3 250MCM 4F225/N 1 2 1/2" 3 4/0 4F200/N 1 2" 3 3/0 6F175/N 1 2" 3 2/0 6F150/N 1 2" 3 1/0 6F125/N 1 2" 3 1/0 6F110/N 1 1 1/2" 3 1 6F100/N 1 1 1/2" 3 1 8F90/N 1 1 1/4" 3 2 8F80/N 1 1 1/4" 3 2 8F70/N 1 1 1/4" 3 4 8F60/N 1 1 1/4" 3 4 10F50/N 1 1" 3 6 10F40/N 1 1" 3 8 10F30/N 1 3/4" 3 10 10F20/N 1 3/4" 3 12 12
F4000 11 4" 4 500MCM 500MCMF3000 8 4" 4 500MCM 500MCMF2500 7 4" 4 500MCM 350MCMF2000 6 4" 4 500MCM 250MCMF1600 5 4" 4 500MCM 4/0F1200 4 4" 4 350MCM 3/0F1000 3 4" 4 500MCM 2/0F900 3 4" 4 350MCM 2/0F800 3 4" 4 350MCM 1/0F700 2 4" 4 500MCM 1/0F600 2 4" 4 350MCM 1F500 2 3" 4 250MCM 2F400 22 2 1/2" 4 3/0F350 1 4" 4 500MCM 2F300 1 4" 4 350MCM 4F275 1 4" 4 350MCM 4F250 1 3" 4 250MCM 4F225 1 3" 4 4/0 4F200 1 2 1/2" 4 3/0 6F175 1 2" 4 2/0 6F150 1 2" 4 1/0 6F125 1 2" 4 1/0 6F110 1 2" 4 1 6F100 1 2" 4 1 8F90 1 2" 4 2 8F80 1 2" 4 2 8F70 1 1 1/2" 4 4 8F60 1 1 1/2" 4 4 10F50 1 1 1/4" 4 6 10F40 1 1" 4 8 10F30 1 3/4" 4 10 10F20 1 3/4" 4 12 12
COPPER CONDUCTORSTHW 600V (AWG)
QUAN. SIZE QUAN. SIZE
CONDUCTORS IN EACH CIRCUIT
PHASE/NEUTRALFEEDER
TYPE
CONDUITSIZE ANDQUANTITY
EQUIPMENTGROUND
WIRE SIZE
+1#4 ISO.GRD.
FULLY BUSSED
SF-IB2
CHEMICAL TYPE GROUND ROD
1#4/0GRD.-2"C
PM
S1-1
TYP.
TYP.
3
AHU-1
PROVISIONS FOR(4) 400A 3P CB'S
& METERING175A3P
3-20HP SF3-10HP RF
9A
25A
30HP40A
55A
105A
82A 50A 31A
14A 60A 60A 80A
377A163A
45A 43A 40A 61A
61A
295A
108A
DETAIL "A' -BLDG "IB2" SINGLE LINE DIAGRAM
DETAIL "B' -SWITCH "PMS1" PARTIAL SINGLE LINE DIAGRAM
105A
CONNECTED: 45A AT 208/120V-3PHASE-4W
110A3P
125A3P
UPS BAYPASS PANEL "UPBP"
208V, 3 PHASE, 4, WIRE 100A
+1#4 ISO.GRD.
EATON "9355" SERIES
110A3P
COMPTON COLLEGE BLDG IB2
MAIN SWITCHBORAD “MDBH” LOAD CALCULATION
LOAD DESCRIPTION REMARKS
PANEL HA1 20775 25AHU-2 102213 123
ELEVATOR 33240 40
PANEL DHM1 45705 55
0
PANEL DPP1 135720 163.32
PANEL DPP2 106200 127.8
TOTAL CONNECTED LOADS 443853 534
CONNECTED(KVA)
CONNECTEDCURRENT(A)
400A3P
12
SEE SHEETE0-0.2A FOR
CONTINUATION
MDBH-8
400A3P
MDBH-9
13
PLAN NOTES:
PROVIDE SHUNT TRIP MECHANISM ON MAIN CIRCUIT BREAKER SERVING THE ELEVATOR. THE HEAT DETECTORS IN THE ELEVATOR MACHINE ROOM AND ON TOP OF ELEVATOR SHAFT, UPON DETECTION OF HEAT, SHALL SHUTDOWN POWER TO THE ELEVATOR. INSTALL IN ACCORDANCE WITH ASME 17.1, NFPA AND ELEVATOR MANUFACTURER'S REQUIREMENTS.
PROVIDE (3) 1/0, 8KV, 115 MIL/133%, EPR, MV-105 UL CLASS & TEMP RATING, T5 SHIELDING, COPPER, (1) #6 GRD. - (N) 4"C.
225 AMPERE - 120/208V.3PH.4W ELECTRONIC GRADE PANELBOARD WITH MAIN CIRCUIT BREAKER, INTERNAL SURGE PROTECTOR DEVICE (SPD), EQUIPMENT GROUND AND ISOLATED GROUND BUS.
PROVIDE COMPLETE NETWORKED METERING SYSTEM PER SPECIFICATION STATION 26 0910.
SEE DETAIL "A" ON THIS SHEET FOR CONTINUATION.
SEE DETAIL "B" ON THIS SHEET FOR CONTINUATION.
PROVIDE 3/4"C. - 2#10, 1#10 GRD.
100 AMPERE - 120/208V.3PH.4W ELECTRONIC GRADE PANELBOARD WITH MAIN CIRCUIT BREAKER, INTERNAL SURGE PROTECTOR DEVICE (SPD), EQUIPMENT GROUND AND ISOLATED GROUND BUS.
1
2
3
4
5
6
7
8
SINGLE LINE DIAGRAM GENERAL NOTES:
1. THE INTERRUPTING CAPACITY OF THE CIRCUIT BREAKERS IN 120/208 VOLT PANELBOARDS SHALL BE 10,000 A.I.C. TYPICAL, UNLESS NOTED OTHERWISE OR REQUIRED BY THE SHORT CIRCUIT STUDY.
2. CIRCUIT BREAKERS IN 120/208 VOLT DISTRIBUTION BOARDS SHALL BE SERIES RATED WITH DOWNSTREAM PANELBOARDS CIRCUIT BREAKERS FOR 22,000 A.I.C. UNLESS NOTED OTHERWISE OR REQUIRED BY THE SHORT CIRCUIT STUDY.
3. THE INTERRUPTING CAPACITY OF THE CIRCUIT BREAKERS IN 480/277 VOLT PANELBOARD SHALL BE 18,000 A.I.C. TYPICAL, UNLESS NOTED OTHERWISE OR REQUIRED BY THE SHORT CIRCUIT STUDY.
4. CIRCUIT PROTECTIVE DEVICES IDENTIFIED AS "SERIES RATED" OR "CURRENT LIMITING" (I.E., SR-SERIES RATED CIRCUIT BREAKER, CLCB-CURRENT LIMITING CIRCUIT BREAKER; CLF-CURRENT LIMITING FUSE, ETC.) SHALL BE SERIES RATED AND TESTED (UL 489 & CSA5) BY THE MANUFACTURER WITH ALL EQUIPMENT AND CIRCUIT PROTECTIVE DEVICES INSTALLED DOWN STREAM OF THE IDENTIFIED SERIES RATED OR CURRENT LIMITING DEVICE FOR 65,000 A.I.C. PROVIDE NAME PLATES ON ALL EQUIPMENT LOCATED DOWN STREAM, INCLUDING THE SR, CLCB AND CLF DEVICES, TO COMPLY WITH C.E.C. PARAGRAPHS 110-22 AND 240-86 "CAUTION SERIES RATED COMBINATION SYSTEM RATED NEW DEVICE INSTALLATIONS AND REPLACEMENTS SHALL BE OF THE SAME MANUFACTURER AND MODEL".
5. CIRCUIT BREAKERS RATED 1,200 AMPS AND GREATER SHALL COMPLY WITH ARC ENERGY REDUCTION PER C.E.C. 240.87 AND PER SPECIFICATIONS 262413.
6. PROVIDE SHORT CIRCUIT PROTECTIVE DEVICE COORDINATION AND ARC-FLASH STUDY INCLUDING THE ENGINEERED SETTINGS FOR EACH FUSE AND ADJUSTABLE CIRCUIT BREAKER SHOWING THE CORRECT TIME AND CURRENT SETTINGS TO PROVIDE COORDINATION WITHIN THE LIMITS OF THE SPECIFIED EQUIPMENT. REFER TO SPECIFICATIONS 262413 FOR ADDITIONAL REQUIREMENTS.
7. MAIN ELECTRICAL SERVICE SHALL NOT BE ENERGIZED UNTIL BUILDING INSPECTORS RECEIPT AND APPROVAL OF A THIRD PARTY NRTL TESTING LABORATORY PERFORMANCE TEST CERTIFICATION FOR THE SERVICE GROUND FAULT PROTECTION PER C.E.C. 230.95.
8. THE DIMENSIONS USED FOR SWITCHBOARDS ARE BASED UPON SQD MANUFACTURED PRODUCTS. IF ANOTHER MANUFACTURES PRODUCT IS FURNISHED, CONTRACTOR SHALL INSURE THAT THE PRODUCT WILL FIT WITHIN THE SPACE PROVIDED.
Co
nsu
ltin
g E
lectr
ical E
ng
ineers
15
0 P
au
larin
o A
ven
ue S
uite
A1
20
Co
sta M
esa
, C
A 9
26
26
94
9.8
52.9
995
•9
49
.852
.165
7 (
fax)
fbaen
gr.
com
FBA
FB
A J
ob
Nu
mber:
En
gin
ee
rin
g
consultant
architect
INST
RU
CTI
ON
AL B
UIL
DIN
G N
o.2
CO
MP
TO
N C
OLL
EG
E
CO
MP
TO
N C
OM
MU
NIT
Y C
OL
LE
GE
DIS
TR
ICT
11
11
E.
AR
TE
SIA
BL
VD
. C
OM
PT
ON
, C
A.
arc
hite
cture
pla
nnin
gin
terio
rstB
P/A
rchi
tect
ure
4611
Te
ller
Ave
nue
Ne
wpo
rt B
each
, C
A 9
2660
ph:
949
.673
.030
0 f
x: 9
49.7
32.3
895
ph: (213) 897-3995 fx:(213) 897-3159
Los Angeles, CA 90012355 South Grand Avenue, Suite 2100
DIVISION OF THE STATE ARCHITECT
tBP project number:
file name:
drawn by: checked by:
date:
drawing title:
drawing no.:
owner
description:date:rev:
THIS DRAWING AND THE DESIGNS, DEPICTIONS, IDEAS AND OTHER INFORMATION CONTAINED HEREIN CONSTITUTE UNPUBLISHED WORK OF tBP/ARCHITECTURE AND SHALL REMAIN PROPERTY OF tBP/ARCHITECTURE IN PERPETUITY. NO PART THEREOF SHALL BE
REPRODUCED, DISCLOSED, DISTRIBUTED, SOLD, PUBLISHED OR OTHERWISE USED IN ANY WAY WITHOUT THE ADVANCED EXPRESS WRITTEN CONSENT OF tBP/ARCHITECTURE.
drawing of
04 / 08 / 2019
20998.00
agency
21
2.2
27
Addendum 108/02/191
Addendum 209/04/192
9/3
/201
9 1
0:0
6:0
0 A
M SINGLE LINE DIAGRAM
E0-0.2
2
S
SS
F200F100F100F100 F400F200 F600
F400/N
F600/NF200/NF400/N
PW1
PDADMINC29 COMP
PD E1 ADMIN C29 COMP
MODUAR E1
PB PA
PQ1PQ2PQ3
MD
BH
-8
2
2
ED
SB
-F
(E) SWITCHGEAR"PMS-2"-5KV
1111
1010
10 10
1414
1414
14
10
4
4
10 10
5
7
4
4
10
8
4
13
6
6
6
F800
F800
F800
PMS-2
600A3P
600A3P
100A3P
100A3P
100A3P
100A3P
SPARE SPARE
1 2 3 4
"TPW1"75KVA4.160KV/120-208V3PH, 4W
(E)PM1
WEATHERPROOF
(E)5KV FEEDER
(E)5KV FEEDER TO PMS-3
WEATHERPROOF
(TYP.) 1
208-120V, 3 , 4W-800ADISTRIBUTION SWITCHBOARD "NDSB"
4W ,225 KVA208/208-120VXFMR "TC"
400AS400AF
CSW-F13NDSB-G
TC-1
CSW-GTC-G
MIN. A.I.C.: 65000A
WEATHERPROOF
X 9 (TYP.)EDSB-1
800A BUS
XEDSB-2
C29 AC UNITS
ND
SB
-2
3P200A
EDSB-3
ND
SB
-3
3P100A
EDSB-4
ND
SB
-4
3P100A
EDSB-5
WEATHERPROOF
ED
SB
-1
GROUND BUS
3P400A
3P
1200AS
208-120V, 3PH, 4W1200A(E)DISTRIBUTION SWITCHBOARD "EDSB"
4W 500 KVA/208-120V, 3PH4.16 KV(E)XFMR "ETD"
"E" HIGH VOLTAGE SWITCH EHD
5KV-3PH-100A
100AS100AF
WEATHERPROOF
WEATHERPROOF
X9(TYP.)NDSB-1
ND
SB
-1
1000A BUS
ED
SB
-3
3P200A
XNDSB-2
C29 AC UNITS
ND
SB
-2
ED
SB
-4
3P200A
NDSB-3
ND
SB
-3
ED
SB
-5
NDSB-4
ND
SB
-4
ED
SB
-5
3P100A
NDSB-5
ND
SB
-5
ND
SB
-5
XXX
3P100A
X
MODULAR BLDG
(E) BUILDING "D-WEST" LOADS
HV
FD
-13
3
1200AT
ND
SB
-1
3P400A
ND
SB
-6
11 (TYP.)
11
BLDG.D EAST
BLDG.D EAST
(E) CONNECTION
FUSED SWITCH"CSW"
480V-3P-600AWEATHERPROOF
3P200A
2400V/240-120V-1PH
(E)XFMR "ETD1"
"E" HIGH VOLTAGE SWITCH EHVD
5KV-2P-100A
WEATHERPROOF240-120V, 1PH, 3W600A(E)DISTRIBUTION PANELBOARD "PDB"
X9(TYP.)NDSB-9
PD
B1
PD
B2
BLDG C BLDG C
XNDSB-8
11
50KVA
GROUND BUS
3P800A
FUTURE STUDENT SERVICE BLDG.
X
DP
Q-1
DP
Q-2
2P200A
2400V/240-120V-1PH(E)XFMR "TQ1"
200KVA
X
2400V/240-120V-1PH(E)XFMR "TQ2"
50KVA
TO EXISTING 2400V-1PH SOURCE
DP
Q-3
X
SEE SHEET E0-0.2A FOR CONTINUATION
PM
S2-F
1&
F2
(E)2400V-1PH SWITCH(E)2400V-1P SWITCH
2P400A
WEATHERPROOF2400 V/240-120V-1PH-400A
(E)HV SWITCH/TRANSFORMER"HSTQ"
TO EXISTING 2400V-1PH SOURCE
PM
S2-F
1
PMS2-F2
FROM PMS-1
2P600A
3P800A
208/120V-3PH-800ADISTRIBUTION PANELBOARD "DPQ"
800AS800AF
QSW-F
FUSED SWITCH"QSW"
240V-3P-800A
WEATHERPROOF
18
11
19
20
18 19
480V/208-120V-3PH-4W"QT"
600V-3PH-500AMCBQ
225KVA
3P400A
MDBH-9
SEE SHEET E0.02 FOR CONTINUATION
QT-F
DPQ-G1"C.- 1#1/O GRD.
1
17
11
9 (TYP.)
MCBQ-F
(TYP.)
QT-G
1"C.- 1#1/O GRD.
MCBQ-G
1"C.- 1#1/O GRD.
3
3P100A
FEEDER SCHEDULE
F800/N 3 3" 3 350MCM 1/0F700/N 2 4" 3 500MCM 1/0F600/N 2 3" 3 350MCM 1F500/N 2 2 1/2" 3 250MCM 2F400/N 2 2" 3 3/0 2F350/N 1 4" 3 500MCM 2F300/N 1 3" 3 350MCM 4F275/N 1 3" 3 350MCM 4F250/N 1 2 1/2" 3 250MCM 4F225/N 1 2 1/2" 3 4/0 4F200/N 1 2" 3 3/0 6F175/N 1 2" 3 2/0 6F150/N 1 2" 3 1/0 6F125/N 1 2" 3 1/0 6F110/N 1 1 1/2" 3 1 6F100/N 1 1 1/2" 3 1 8F90/N 1 1 1/4" 3 2 8F80/N 1 1 1/4" 3 2 8F70/N 1 1 1/4" 3 4 8F60/N 1 1 1/4" 3 4 10F50/N 1 1" 3 6 10F40/N 1 1" 3 8 10F30/N 1 3/4" 3 10 10F20/N 1 3/4" 3 12 12
F4000 11 4" 4 500MCM 500MCMF3000 8 4" 4 500MCM 500MCMF2500 7 4" 4 500MCM 350MCMF2000 6 4" 4 500MCM 250MCMF1600 5 4" 4 500MCM 4/0F1200 4 4" 4 350MCM 3/0F1000 3 4" 4 500MCM 2/0F900 3 4" 4 350MCM 2/0F800 3 4" 4 350MCM 1/0F700 2 4" 4 500MCM 1/0F600 2 4" 4 350MCM 1F500 2 3" 4 250MCM 2F400 22 2 1/2" 4 3/0F350 1 4" 4 500MCM 2F300 1 4" 4 350MCM 4F275 1 4" 4 350MCM 4F250 1 3" 4 250MCM 4F225 1 3" 4 4/0 4F200 1 2 1/2" 4 3/0 6F175 1 2" 4 2/0 6F150 1 2" 4 1/0 6F125 1 2" 4 1/0 6F110 1 2" 4 1 6F100 1 2" 4 1 8F90 1 2" 4 2 8F80 1 2" 4 2 8F70 1 1 1/2" 4 4 8F60 1 1 1/2" 4 4 10F50 1 1 1/4" 4 6 10F40 1 1" 4 8 10F30 1 3/4" 4 10 10F20 1 3/4" 4 12 12
COPPER CONDUCTORSTHW 600V (AWG)
QUAN. SIZE QUAN. SIZE
CONDUCTORS IN EACH CIRCUIT
PHASE/NEUTRALFEEDER
TYPE
CONDUITSIZE ANDQUANTITY
EQUIPMENTGROUND
WIRE SIZE
600AS
SINGLE LINE DIAGRAM KEY NOTES:
PROVIDE 12" X 12" X 12"D. BOTTOMLESS CONCRETE PULLBOX WITH PEA GRAVEL BASE AND CHEMICAL ASSEMBLY GROUND ROD. MOUNT PULLBOX FLUSH ON GRADE AND ENGRAVE COVER "GROUND"; QUANTITY AS REQUIRED TO ACHIEVE 25 OHMS TO GROUND MAXIMUM.
PROVIDE (3) 1/0, 8KV, 115 MIL/133%, EPR, MV-105 UL CLASS & TEMP RATING,T5 SHIELDING, COPPER, (1) #6 GRD. - (N) 5"C.
PROVIDE 1 1/2"C. 1#3/O GRD.
EXISTING ELECTRICAL EQUIPMENT SERVING BUILDINGS "D", "C", "ADMIN" AND LIBRARY SHALL REMAIN DURING THE CONSTRUCTION OF "IB2" AND DEMOLITION OF WEST PORTION OF BUILDING "D". THESE EQUIPMENT SHALL BE DISCONNECTED AND REMOVED WHEN POWER EQUIPMENT DESCRIBED UNDER NOTE "6" WILL BE INSTALLED AND ENERGIZED.
EXISTING HIGH VOLTAGE FEEDER SHALL BE DISCONNECTED AND REMOVED. SEE SHEET ES-1.0 FOR ADDITIONAL INFORMATION.
NEW POWER EQUIPMENT FOR BACK FEED OF BUILDING "C", BUILDING "D-EAST", LIBRARY AC UNITS, ADMIN AND PORTABLE BUILDING.
EXISTING BUILDING "D-WEST" FEEDERS TO BUILDING "D" PANELS SHALL BE DISCONNECTED AND REMOVED BEFORE DEMOLITION OF BUILDING "D-WEST".
EXISTING BUILDING "D" DISTRIBUTION SWITCHBOARD SHALL REMAIN OPERATIONAL DURING IB2 CONSTRUCTION AND BE REMOVED AS PART OF DEMOLITION OF BUILDING "D-WEST".
INTERCEPT AT EXISTING FEEDER OF EXISTING LOAD AND RE-ROUTE TO NEW DISTRIBUTION SWITCHBOARD.
EXISTING HIGH VOLTAGE FEEDER SHALL BE REMOVED.
EXISTING FEEDER SHALL BE REMOVED.
DISCONNECT AND REMOVE EXISTING EQUIPMENT AFTER NEW POWER SYSTEM WILL BE INSTALLED IN BUILDING "Q".
STUB-OUT 1-4" CONDUITS. SEE SHEET ES-1.1 FOR ADDITIONAL INFORMATION.
DISCONNECT AND REMOVE EXISTING HIGH VOLTAGE EQUIPMENT OF BUILDING "Q" AFTER NEW POWER SYSTEM WILL BE INSTALLED AND ENERGIZED.
NOT USED.
CONNECT TO EXISTING BUILDING GROUND. TEST EXISTING BUILDING GROUND AND IF THE RESISTANCE IS MORE THAN 25 OHM, ADD ADDITIONAL GROUND ROD AS INDICATED.
PROVIDE 1"C.- 1#1/O GRD.
PROVIDE TWO (2) SETS OF 4#500 MCM, 1#1/O GRD. IN EACH ONE 3" CONDUIT.
THIS FEEDER FEEDS BUILDING "Q" POWER SYSTEM DURING THE CONSTRUCTION OF "IB2" PROJECT AND DEMOLITION OF WEST PART OF BUILDING "D". AFTER EXTENSION NEW FEEDER FROM "IB2" AND INSTALLATION OF NEW EQUIPMENT IN BUILDING "Q" IT SHALL BE DISCONNECTED AND REMOVED.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
Co
nsu
ltin
g E
lectr
ical E
ng
ineers
15
0 P
au
larin
o A
ven
ue S
uite
A1
20
Co
sta M
esa
, C
A 9
26
26
94
9.8
52.9
995
•9
49
.852
.165
7 (
fax)
fbaen
gr.
com
FBA
FB
A J
ob
Nu
mber:
En
gin
ee
rin
g
consultant
architect
INST
RU
CTI
ON
AL B
UIL
DIN
G N
o.2
CO
MP
TO
N C
OLL
EG
E
CO
MP
TO
N C
OM
MU
NIT
Y C
OL
LE
GE
DIS
TR
ICT
11
11
E.
AR
TE
SIA
BL
VD
. C
OM
PT
ON
, C
A.
arc
hite
cture
pla
nnin
gin
terio
rstB
P/A
rchi
tect
ure
4611
Te
ller
Ave
nue
Ne
wpo
rt B
each
, C
A 9
2660
ph:
949
.673
.030
0 f
x: 9
49.7
32.3
895
ph: (213) 897-3995 fx:(213) 897-3159
Los Angeles, CA 90012355 South Grand Avenue, Suite 2100
DIVISION OF THE STATE ARCHITECT
tBP project number:
file name:
drawn by: checked by:
date:
drawing title:
drawing no.:
owner
description:date:rev:
THIS DRAWING AND THE DESIGNS, DEPICTIONS, IDEAS AND OTHER INFORMATION CONTAINED HEREIN CONSTITUTE UNPUBLISHED WORK OF tBP/ARCHITECTURE AND SHALL REMAIN PROPERTY OF tBP/ARCHITECTURE IN PERPETUITY. NO PART THEREOF SHALL BE
REPRODUCED, DISCLOSED, DISTRIBUTED, SOLD, PUBLISHED OR OTHERWISE USED IN ANY WAY WITHOUT THE ADVANCED EXPRESS WRITTEN CONSENT OF tBP/ARCHITECTURE.
drawing of
04 / 08 / 2019
20998.00
agency
21
2.2
27
Addendum 108/02/191
Addendum 209/04/192
9/3
/201
9 1
0:0
6:0
6 A
M SINGLE LINE DIAGRAM
E0-0.2ASINGLE LINE DIAGRAM - BUILDING D AND MODULAR BUILDING
SINGLE LINE DIAGRAM - BUILDING C, ADMIN., BUILDING "D-EAST" AND LIBRARY AC UNIT POWER DISTRIBUTION SYSTEM
2
4" MIN. RAISED CONCRETEHOUSEKEEPING PAD , SEESTRUCTURAL FOR ADDITIONALINFO & DETAILS
1/2" DIAMETER HILTI KB-TZ (ICC-ESR 1917)EXPANSION ANCHOR 4 REQUIRED.
TRANSFORMER
2 1/2" MIN.EMBED DEPTH
MAX. WEIGHT:2374 LBS
30"
TO CENTEROF MASS
46" MAX.
8
S0-1.1
LYNCOLE XIT GROUNDING SYSTEM
WEEP HOLES
PROTECTIVE COVER BOX
BREATHER HOLE
EXOTHERMIC WELD CONNECTION
#2 SOLID to 1000 MCM
FINISHED GRADE
BACKFILL
SLOTTED BOLT DOWN COVER
UL NAME PLATE
SOIL
STRAIGHT SHAFT MODEL: INFORMATION & SPECIFICATIONS
A. Manufacturer: Lyncole XIT Grounding, 3547 Voyager St., Ste. 204
Torrance, CA 90503, Phone 800-962-2610.
www.Lyncole.com
B. Shaft configuration: Straight.
Standard lengths: 10', 12', 20' & 40', or custom.
C. UL and CSA Listing: 467.
D. Lynconite II and Grounding Gravel backfill meet ANSI/NSF Enviromental Standard 60.
E. Material: Type K Copper 0.083" nominal wall thickness.
F. Construction: Hollow tube, 2.125" O.D., filled with non-
hazardous salts (Calsolyte).
G. Weight: 3.5 lbs per lineal foot.
H. Ground Wire Termination: Exothermic connection to conductors
from #2 solid AWG to 1000 MCM. U-bolt with pressure
plate provided as test point.
I. Warranty: 30 years. Minimum Life Expectancy: 50 years.
J. Straight Shaft Model No: K2-10CS, K2-12CS, K2-20CS, K2-2-40CS (coupled 20 ft. sections)
K. GSA Contract pricing Available.
LYNCONITE II/GROUNDING GRAVEL
UPS1380 #
BATTCAB.
2166 #
3/8" HILTI KB-TZEXPANSION ANCHOR AT8 LOCATIONS (4 PER UNIT)
PLAN VIEW
FRONT VIEW
BATTERY CABINET
UPS
35.5"
23.5" 23.5"
35.5"
SIGNAL
PULLBOX GROUP TYPE "A"
30"
17"
TYPICAL LAYOUT
FIREALARM
ELECTRIC
FIRE ALARM
PULLBOX GROUP TYPE "B"
SIGNAL
24"
36"
17"
30"
48"
30"
36"
24"
4"
FINISH GRADE
6" DRAIN COVERFLUSH WITH FLOOR
6" CRUSHED STONE
TOP OF FINISHED GRADESET PULL BOX 1" ABOVE
A.C. TO JOIN PULLBOX.RAMP 10% LOCALLY WITH
DEPTH AS REQUIRED
OR GRAVEL
CAST IRON LOCKABLETRAFFIC COVER
NEW CEMENT CONCRETE
NEW CEMENT CONCRETE
6"
4"
20"x20"TYP. KNOCKOUT
CABLE RACK TYP.
8"x16"TYP. KNOCKOUT
3/4" PULL IRON TYP.FOR ALL PULL BOXES
DETAIL NOTES:
1. IN THE PRECAST CONCRETE PULL BOXES FURNISH AND INSTALLCABLE RACKS ON WALLS INDICATED. EACH RACK SHALL BEEQUIPPED WITH THREE PORCELAIN CABLE HOLDERS ON AVERTICAL STEEL MOUNTING BAR. BOLT HOLES SHALL BE PRE-CASTPULL BOXES JENSEN PRECAST OR EQUAL WITH STAINLESS STEELFLAT HEAD SCREWS AND SELF CLEANING HOLES. LOOP ALL CABLESAROUND THE LONGEST LENGTH IN THE PULL BOX.
2. PROVIDE NON SLIP COATING ON COVERS.
3. ALL METAL PARTS SHALL BE HOT-DIPPED GALVANIZED AFTERFABRICATION.
4. "BROOKS" YARD BOX OR EQUAL WITH 9 1/2" X 16" I.D. CONCRETEBOX (NO. 3 BODY) WITH 3-TL CAST IRON COVER, UTILITY NAME(ELECTRICAL, SIGNAL, FIRE ALARM, ETC.) EMBOSSED 1/16"ABOVESURFACE, 1" HIGH UPPERCASE.
10"
4"
48"91.5"
TRANSFORMER TC
DISTRIBUTION
24'X36"X6"D
6"
6"
48"
SWITCHBOARD "NDSB"
6"
24"
50"
36"
24"
48"
6"
24"
800A
6"
HILTI KB-TZ ANCHORS 3/4"DIA., EMBEDDED 2" INTOCONC. SLAB (ICC ER-1917)TYP. 4 FOR EACH UNIT
WALLMOUNTED
FUSED SWITCH
24"
6"
FUSED SWITCH
TRANSFORMER
WEIGHT:200 LBS MAX
WEIGHT:2100 LBS MAX
CONCRETE PAD
SEE STRUCTURAL
ELECTRICAL EQUIPMENT ELEVATIONS
TOP ELEVATION
FRONT ELEVATIONSCALE:NONE
SCALE:NONE
8
S0-1.1
3" TYP.
5 OR 4
3
10
6
2
2" TYP.
2" TYP. 2" TYP. 3" TYP.
3" TYP.
1
7
SEE SINGLE LINE DIAGRAM FOR NUMBER AND SIZE OF CONDUITS
7" MAIN EDGE DISTANCE
PLAN VIEW
FRONT VIEW
TYPICAL SECTION
91.5"
4" PAD
HILTI KB-TZ ANCHORS 1/2" DIA., W/ 3-1/4" EFF. EMBED (ICC ESR-1917)
4" MIN CONCRETE HOUSEKEEPING PAD
INDICATES ANCHOR BOLT LOCATIONS
30"
30" 36"
MAIN DIST.
4" PAD
91.5"
30" 36"
THE DIMENSIONS INDICATED ARE MAXIMUM ALLOWABLE SIZES.
DIST.
36"
36"
8
S0-1.1
Co
nsu
ltin
g E
lectr
ical E
ng
ineers
15
0 P
au
larin
o A
ven
ue S
uite
A1
20
Co
sta M
esa
, C
A 9
26
26
94
9.8
52.9
995
•9
49
.852
.165
7 (
fax)
fbaen
gr.
com
FBA
FB
A J
ob
Nu
mber:
En
gin
ee
rin
g
consultant
architect
INST
RU
CTI
ON
AL B
UIL
DIN
G N
o.2
CO
MP
TO
N C
OLL
EG
E
CO
MP
TO
N C
OM
MU
NIT
Y C
OL
LE
GE
DIS
TR
ICT
11
11
E.
AR
TE
SIA
BL
VD
. C
OM
PT
ON
, C
A.
arc
hite
cture
pla
nnin
gin
terio
rstB
P/A
rchi
tect
ure
4611
Te
ller
Ave
nue
Ne
wpo
rt B
each
, C
A 9
2660
ph:
949
.673
.030
0 f
x: 9
49.7
32.3
895
ph: (213) 897-3995 fx:(213) 897-3159
Los Angeles, CA 90012355 South Grand Avenue, Suite 2100
DIVISION OF THE STATE ARCHITECT
tBP project number:
file name:
drawn by: checked by:
date:
drawing title:
drawing no.:
owner
description:date:rev:
THIS DRAWING AND THE DESIGNS, DEPICTIONS, IDEAS AND OTHER INFORMATION CONTAINED HEREIN CONSTITUTE UNPUBLISHED WORK OF tBP/ARCHITECTURE AND SHALL REMAIN PROPERTY OF tBP/ARCHITECTURE IN PERPETUITY. NO PART THEREOF SHALL BE
REPRODUCED, DISCLOSED, DISTRIBUTED, SOLD, PUBLISHED OR OTHERWISE USED IN ANY WAY WITHOUT THE ADVANCED EXPRESS WRITTEN CONSENT OF tBP/ARCHITECTURE.
drawing of
04 / 08 / 2019
20998.00
agency
21
2.2
27
Addendum 108/02/191
Addendum 209/04/192
9/3
/201
9 1
0:0
6:0
9 A
M ELECT. ANCHORAGEDETAILS
E0-0.6
UNDERGROUND CONDUIT DUCT BANK DETAIL 1SCALE
N.T.S.
DRAWING SHEET PLAN NOTES
1. CAST-IN PLACE RED MIX CONCRETE CONTINUOUS ENTIRE LENGTH.CONCRETE COVERAGE NOT LESS THAN 3-INCH ALL SIDES OF CONDUIT DUCT BANK.
2. NATIVE SOIL BACKFILL.
3. CONTINUOUS 1#4/0 BARE COPPER DUCT BANK BONDING/GROUND CONDUCTOR.
4. CONTINUOUS 5 INCH CONDUIT AND 4160 VOLT CIRCUIT POWER CONDUCTORS.
5. 3" WIDE WARNING TAPE LOCATED 12" BELOW GRADE. TAPE SHALL INDICATE:"CAUTION BURIED ELECTRICAL CONDUIT".
6. DAMP SAND BACKFILL TO WITHIN 12" OF FINISH GRADE.
7. INTRA-CONDUIT SPACING 2 INCH.
8. HOMERUN AND CONNECT EQUIPMENT BOND CONDUCTOR TO BUILDING EQUIPMENT GROUND BUS - GB.
9. 1"C. - 1#8, CONNECT TO CABLE TRENCH EXPOSED METAL COVER/FRAME FOR CONTINUOUS BOND/GROUND OF EACH ISOLATED METAL COMPONENTS.
10. 36" IN TRAFFIC AREAS, 24" IN NON-TRAFFIC AREAS.
DISTRIBUTION SWITCHBOARD ANCHORAGE DETAIL 3
SCALE
N.T.S. 4CHEMICAL GROUND ROD DETAIL
UPS ANCHORAGE DETAIL
TYPICAL PRECAST CONCRETE PULLBOX DETAILS 6
SCALE
N.T.S.
SCALE
N.T.S.TYPICAL TRANSFORMER ANCHORAGE DETAIL 2
SCALE
N.T.S. 5
SCALE
N.T.S.
SCALE
N.T.S.NEW POWER SERVICE EQUIPMENT ANCHORAGE DETAILS 7
2
ALLIED HEALTH PROJECT SITE
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
C
C
C
C
C
C
C
C
E
E
C
E
E
E
E
E
2
2
2
2
2
2
2
1
1
1
1
2
2
1
AREA OF DEMOLITION WORK
5
3
5
PMS1
---
6
(E) PMH-6
(E) PMH-7
(E) PMH-8
E
E
FOOTPRINT OF IB2
7
8
FOOTPRINT OF (E)IB1
11
11
3
11
EHD
E0-0.2A
11
ETD
E0-0.2A
11
EDSB
E0-0.2A
PD
-
PA
-
(E)
PB
-
(E)
21
21
20EDSB-1
EDSB-2
EDSB-5
20
EDSB-4
13
NDSB-5
NDSB-2
4
19
14
17
NDSB-3
E
E
E
E
E
TO EXISTING PANEL IN
ADMIN BLDG
NDSB-4
23
22
4
EHVD
E0.-0.0.2A
ETD1
E0.-0.2.A
PDB
E0-0.2.A
11
(E)HVFD-1
11
(E)
10
EDSB-416
E1
-
(E)
PMS-2
E-0.02A
(E)
PMS2-F1
NDSB-3
X
X
NDSB-4
12
23
(TYP.)
3
3
3
24
12
12NDSB-2
NDSB-3
12
NDSB-6
QSW
E0-0.2A
3
EQ-1.1
2
EQ-1.1
QSW-F
12
25
E
18
26
(E)SEWER LINE FOR
BUILDING C&D
30
QSW-F
PMS2-F2
29
PME-27
(E)
4
9
PMS2-F1
27
PMS2-F2
28
PMS2-F1
27
PMS2-F2 28
(E)
(E)
4
PMH-10
11
EDSB-F
32
3133
IN
ST
RU
CT
IO
NA
L B
UIL
DIN
G N
o. 2
CO
MP
TO
N C
OM
MU
NIT
Y C
OL
LE
GE
D
IS
TR
IC
T
11
11
E
. A
RT
ES
IA
B
LV
D. C
OM
PT
ON
, C
A.
file name:
drawn by: checked by:
drawing no.:
drawing of
arch
ite
ctu
re
pla
nn
in
g
in
te
rio
rs
tB
P/A
rch
ite
ctu
re
46
11
T
elle
r A
ve
nu
e
Ne
wp
ort B
ea
ch
, C
A 9
26
60
ph
: 9
49
.6
73
.0
30
0 fx: 9
49
.7
32
.3
89
5
ph: (213) 897-3995
Los Angeles, California. 90012
DIVISION OF STATE ARCHITECT
consultant
agency
owner
date: 04/08/2019
drawing title:
description:date:Rev:
tBP project number :
architect
THIS DRAWING AND THE DESIGNS, DEPICTIONS, IDEAS AND OTHER
INFORMATION CONTAINED HEREIN CONSTITUTE UNPUBLISHED WORK
OF tBP/ARCHITECTURE AND SHALL REMAIN THE PROPERTY OF
tBP/ARCHITECTURE IN PERPETUITY. NO PART THEREOF SHALL BE
REPRODUCED, DISCLOSED, DISTRIBUTED, SOLD, PUBLISHED OR
OTHERWISE USED IN ANY WAY WITHOUT THE ADVANCED EXPRESS
WRITTEN CONSENT OF tBP/ARCHITECTURE.
20998.00
CO
MP
TO
N C
OL
LE
GE
355 South Grand Avenue, Suite 2100
Fax: (213) 897-3159
L
A
C
I
RT
C
E
L
Z
A
J
I
C
E
K
E
S
T
E
P
H
E
N
R.
No. E 10372
E
F
O
R
P
D
E
R
E
T
S
I
G
E
R
A
R
E
E
N
I
G
N
E
L
A
N
O
I
S
S
L
I
F
O
R
N
I
A
S
T
A
T
E
O
F
C
Exp.09-30-20
15
0 P
au
la
rin
o A
ve
nu
e S
uite
A
12
0
Co
sta
M
esa
, C
A 9
26
26
94
9.8
52
.9
99
5 9
49
.8
52
.1
65
7 (fa
x)
FBA
En
gin
ee
rin
g
Consulting E
lectrical E
ngineers
fb
ae
ng
r.co
m
FB
A Job N
um
ber:
212.227
Addendum 108/02/191
Addendum 209/04/192
NORTH
SITE ELECTRICAL DEMOLITION PLAN
SCALE: 1"= 30'
KEY NOTES
AFTER COMPLETION OF IB2 PROJECT, DISCONNECT AND REMOVE
ALL EXISTING ELECTRICAL AND TELECOMMUNICATIONS SYSTEMS
FROM BUILDING TO BE DEMOLISHED. ALL ELECTRICAL
EQUIPMENT, ETC. DEEMED SALVAGEABLE BY THE DISTRICT
SHALL BE RETURNED TO THE DISTRICT AND DEPOSITED AT A
LOCATION AS DIRECTED BY THE DISTRICT. COORDINATE ALL
WORK WITH DISTRICT.
ELECTRICAL ITEMS TO BE DISCONNECTED AND REMOVED SHALL
INCLUDE, BUT NOT LIMITED, TO THE FOLLOWING:
SWITCHBOARDS, PANELBOARDS AND ASSOCIATED FEEDERS,
CONDUIT AND WIRING.
RECEPTACLES, OUTLETS, POWER CONNECTIONS, SAFETY
SWITCHES, MOTOR STARTERS, ETC. AND ALL ASSOCIATED
CONDUIT AND WIRING.
INTERIOR AND EXTERIOR LIGHTING FIXTURES, SWITCHES,
OCCUPANCY SENSORS, CONTROLS AND ALL ASSOCIATED
CONDUIT AND WIRING.
FIRE ALARM CONTROL PANELS, POWER SUPPLIES, SMOKE AND
HEAT DETECTORS, PULL STATIONS AND ALL ASSOCIATED
CONDUIT AND WIRING.
TELECOMMUNICATIONS SYSTEMS INCLUDING IDF EQUIPMENT,
TERMINATION DEVICES, SPEAKERS, CLOCKS, ETC. AND ALL
ASSOCIATED CONDUIT AND WIRING.
EXISTING BUILDING TO REMAIN. PROTECT ALL EXISTING
ELECTRICAL, TELECOMMUNICATIONS AND FIRE ALARM
SYSTEMS IN PLACE.
DISCONNECT AND REMOVE EXISTING UNDERGROUND FEEDER.
REMOVE CONDUITS TO MAKE WAY FOR THE NEW
CONSTRUCTION..
EXISTING MANHOLE TO REMAIN. PROTECT IN PLACE.
EXISTING UNDERGROUND PULLBOX SHALL BE ABANDONED.
1
2
3
4
5
LEGEND:
EXISTING UNDERGROUND ELECTRICAL CONDUIT AND CABLING
EXISTING UNDERGROUND COMMUNICATIONS CONDUIT AND CABLING
E
C
ALL EXISTING ELECTRICAL WITHIN THE DEMOLITION AREAS OF THE SITE SHALL
REMAIN UNLESS SPECIFICALLY INDICATED OTHERWISE ON THE ELECTRICAL
DRAWINGS. REFER TO ARCHITECTURAL DEMOLITION DRAWINGS INCLUDED IN
THIS SET FOR DEMOLITION AREAS. THE SCOPE OF THE DEMOLITION WORK
SHALL INCLUDE ALL LABOR, MATERIALS, SERVICES AND EQUIPMENT REQUIRED
FOR THE REMOVAL OF ALL EXISTING ELECTRICAL NOT INDICATED AS BEING
REUSED. THIS WORK INCLUDES, BUT IS NOT LIMITED TO, THE FOLLOWING:
a. ALL EXISTING WIRE SHALL BE REMOVED FROM CONDUIT.
b. ALL EXISTING CONDUIT, THAT INTERFERES WITH ANY NEW CONSTRUCTION
SHALL BE CUT BACK AS REQUIRED TO CLEAR NEW CONSTRUCTION.
c. REMOVE ALL EXISTING EXPOSED CONDUIT, SURFACE RACEWAYS AND
CONDUIT CONCEALED IN EXISTING CONSTRUCTION THAT IS TO BE REMOVED.
RECONNECT OUTLETS AND LIGHTING FIXTURES WHICH ARE NOW FED THROUGH
THE OUTLETS TO BE REMOVED.
d. REMOVE ALL EXPOSED CONDUIT, WIRE, OUTLETS, DISCONNECT SWITCHES
AND ELECTRICAL MOUNTING HARDWARE FOR MECHANICAL EQUIPMENT BEING
REMOVED. PROVIDE WEATHERPROOF CAPS ON ALL CONDUIT PENETRATING
ROOF AND ABANDON CONDUIT. REPAIR ROOFING DAMAGED BY REMOVAL OF
EXISTING ELECTRICAL.
e. EXCEPT WHERE EXPOSED CONDUITS ARE SHOWN ON PLANS, INSTALL ALL
NEW CONDUITS CONCEALED IN WALLS, FURRED CEILING, OR UNDER FLOOR
SPACE.
f. LIGHT FIXTURES AND ELECTRICAL DEVICES INDICATED TO BE REMOVED AND
REINSTALLED SHALL BE REMOVED AND PROPERLY STORED TO PROTECT FROM
DAMAGE UNTIL SUCH TIME THAT IT IS REINSTALLED. ALL FIXTURES TO BE
REINSTALLED SHALL BE FULLY OPERABLE AND SHALL FIRST BE CLEANED,
RELAMPED, DEFECTIVE BALLASTS REPLACED AND CRACKED OR BROKEN
DIFFUSERS/LENSES REPLACED.
g. ALL REMOVED MATERIALS AND EQUIPMENT WHICH IN THE OPINION OF THE
OWNER ARE SALVAGEABLE, SHALL REMAIN THE PROPERTY OF THE OWNER.
DELIVER SUCH SALVAGED MATERIALS AND EQUIPMENT ON PREMISES AS
DIRECTED, AND NEATLY PILE OR STORE THEM AND PROTECT FROM DAMAGE.
h. DO NOT REUSE SALVAGED MATERIALS AND EQUIPMENT, UNLESS
SPECIFICALLY INDICATED ON PLANS OR SPECIFIED. REMOVE FROM PREMISES
AND DISPOSE OF ALL MATERIALS CONSIDERED BY THE OWNER TO BE SCRAP.
DEMOLITION PERFORMANCE NOTES
ES-1.0
SITE ELECTRICAL
DEMOLITION PLAN
EXISTING HIGH VOLTAGE SWITCH TO REMAIN. PROTECT IN PLACE.6
DISCONNECT AND REMOVE EXISTING LIGHT POLE INCLUDING
LIGHT FIXTURE, CONCRETE BASE, CONDUIT AND CONDUCTORS
UP TO SOURCE OF CONNECT.
7
DISCONNECT AND REMOVE EXISTING SECURITY CAMERA.
RELOCATE TO NEW LIGHT POLE. SEE SHEET ES-1.3 FOR
CONTINUATION.
8
INTERCEPT AT EXISTING TWO (2) 5" CONDUIT SPARE AND
RE-ROUTE AS INDICATED.
9
DISCONNECT AND REMOVE EXISTING 5KV FEEDER. REMOVE
CONDUCTORS AND ABANDON UNDERGROUND CONDUITS IN
PLACE.
10
EXISTING BUILDING "D" POWER EQUIPMENT TO REMAIN DURING
CONSTRUCTION OF "IB2" AND DEMOLITION OF BUILDING "D-WEST".
AS SOON AS NEW POWER EQUIPMENT WHICH WILL BE LOCATED
BY BUILDING "C" WILL BE INSTALLED AND BACK FEED THE
EXISTING PANELS THEY SHALL BE DISCONNECTED AND REMOVED
. SEE SHEET ES-1.1 AND E0.0.2.A FOR ADDITIONAL INFORMATION.
11
12
DISCONNECT AND REMOVE EXISTING FEEDER ON THE CANOPY
INCLUDING CONDUCTORS.
13
INTERCEPT AT EXISTING FEEDER ON THE CANOPY AND REROUTE
TO NEW WALL MOUNTED PULL BOX AS INDICATED.
14
SEE SHEET ES-1.1 FOR CONTINUATION.15
DISCONNECT AND REMOVE EXISTING WALL MOUNTED FEEDER
INCLUDING CONDUCTORS.
16
INTERCEPT AT EXISTING FEEDER ON THE WALL AND TERMINATE
IT TO A 2' x 2 x 4"D PULLBOX. SEE SHEET ES-1.1 FOR
CONTINUATION.
17
INTERCEPT AT EXISTING RELOCATABLE BUILDING'S POWER AND
CONNECT TO NEW FEEDER.
18
INTERCEPT AT TWO FEEDER OF BUILDING "C" EAST IN EXISTING
WALL MOUNTED PULLBOX. AND RE-ROUTE TO NEW. SEE SHEET
ES-1.1 FOR CONTINUATION.
19
DISCONNECT AND REMOVE EXISTING UNDERGROUND FEEDER.20
DISCONNECT AND REMOVE EXISTING INCOMING FEEDER TO
EXISTING PANEL. SEE SHEET ES-1.1 FOR CONNECTION TO NEW
SOURCE.
21
PROVIDE WALL MOUNTED 12" x 12" x 4"D WEATHERPROOF
PULLBOX.
22
INTERCEPT AT EXISTING UNDERGROUND FEEDER AND REROUTE
TO NEW POWER DISTRIBUTION PANEL.
23
SEE SHEET ES-1.1 FOR CONTINUATION.
SEE SHEET ES-1.1 FOR CONNECTION TO NEW SOURCE.
EXISTING HIGH VOLTAGE FEEDER TO BUILDING "Q" SHALL BE
REMOVED. SEE SHEET ES-1.1 FOR MORE INFORMATION.
24
EXISTING TERMINAL CABINET WITH ALL TERMINATED
CONDUCTORS SHALL BE DISCONNECTED AND REMOVED.
REMOVE ALL EXPOSED CONDUITS AND ABANDON CONCEALED
CONDUITS.
25
26 DISCONNECT AND REMOVE EXISTING FEEDER TO EXISTING RELO.
27UTILIZE EXISTING (1)5" CONDUIT FOR EXTENDING HIGH VOLTAGE
FEEDER.
UTILIZE EXISTING 5" SPARE CONDUIT FOR FUTURE STUDENT
SERVICE BUILDING.
STUB-OUT (1)5" CONDUIT FOR FUTURE STUDENT SERVICE
BUILDING. VERIFY STUB-OUT LOCATION.
28
29
PROVIDE 2' X 3' X 3'D. UNDERGROUND CONCRETE PULL BOX WITH
BOLT-DOWN TRAFFIC COVER. ENGRAVE: "POWER".
30
INTERCEPT AT INCOMING CONDUCTORS FROM TRANSFORMER
"EDT" TO SWITCHBOARD "EDSB". EXTEND TO WALL AND
TERMINATE TO "QSW".
INSTALL FEEDER ON THE WALL.
31
32
CONDUIT SHALL RISE FROM BELOW GRADE TO THE WALL AND
TERMINATED TO THE SWITCH.
33
TRAILERPARK
TRACT NO.21218
TRACT NO.21218 ALLIED HEALTH PROJECT SITE
PARKING
NO
PARKINGNO
AREA OF WORK
(N)ELECTRICAL EQUIPMENT
ROOM
(N)BDF-IB2
(N) INSTRUCTIONAL
BUILDING #2
(E)INSTRUCTIONAL
BUILDING #1
(A# 117612)
1
3
4
5
6
7
9
11
8
10
12 (TYP)
PMH-1
PMH-2
PMH-3 PMH-5
PMH-9
PMH-27
PMH-10
PMH-6
PMH-7
PMH-8
(E)
(E)
(E) (E)
(E)
(E)
(E)
(E)
(E)
(E)
3
EQ-1.1
2
EQ-1.1
2
-
1
E0-0.4
15
MDBH-8
NDSB-1
NDSB-8
NDSB-9
NDSB-10
NDSB-11
NDSB-12
PA
-
PD
-
PB
-
(E)(E)
(E)
12 (TYP.)
2
MDB3H-922
MDBH-9
MDBH-8
17
18
18
NDSB-6
NDSB-3
NDSB-4
NDSB-2
NDSB-7
NDSB-2
NDSB-5
NDSB-4
18
21
15
MDBH-9
CSW
E0.0.2A
TC
E0.0.2A
NDSB
E0.0.2A
CONCRETE PAD
13
14
16
16
16
BUILDING "C"
19(TYP.)
20
TC-G
IN
ST
RU
CT
IO
NA
L B
UIL
DIN
G N
o. 2
CO
MP
TO
N C
OM
MU
NIT
Y C
OL
LE
GE
D
IS
TR
IC
T
11
11
E
. A
RT
ES
IA
B
LV
D. C
OM
PT
ON
, C
A.
file name:
drawn by: checked by:
drawing no.:
drawing of
arch
ite
ctu
re
pla
nn
in
g
in
te
rio
rs
tB
P/A
rch
ite
ctu
re
46
11
T
elle
r A
ve
nu
e
Ne
wp
ort B
ea
ch
, C
A 9
26
60
ph
: 9
49
.6
73
.0
30
0 fx: 9
49
.7
32
.3
89
5
ph: (213) 897-3995
Los Angeles, California. 90012
DIVISION OF STATE ARCHITECT
consultant
agency
owner
date: 04/08/2019
drawing title:
description:date:Rev:
tBP project number :
architect
THIS DRAWING AND THE DESIGNS, DEPICTIONS, IDEAS AND OTHER
INFORMATION CONTAINED HEREIN CONSTITUTE UNPUBLISHED WORK
OF tBP/ARCHITECTURE AND SHALL REMAIN THE PROPERTY OF
tBP/ARCHITECTURE IN PERPETUITY. NO PART THEREOF SHALL BE
REPRODUCED, DISCLOSED, DISTRIBUTED, SOLD, PUBLISHED OR
OTHERWISE USED IN ANY WAY WITHOUT THE ADVANCED EXPRESS
WRITTEN CONSENT OF tBP/ARCHITECTURE.
20998.00
CO
MP
TO
N C
OL
LE
GE
355 South Grand Avenue, Suite 2100
Fax: (213) 897-3159
L
A
C
I
RT
C
E
L
Z
A
J
I
C
E
K
E
S
T
E
P
H
E
N
R.
No. E 10372
E
F
O
R
P
D
E
R
E
T
S
I
G
E
R
A
R
E
E
N
I
G
N
E
L
A
N
O
I
S
S
L
I
F
O
R
N
I
A
S
T
A
T
E
O
F
C
Exp.09-30-20
15
0 P
au
la
rin
o A
ve
nu
e S
uite
A
12
0
Co
sta
M
esa
, C
A 9
26
26
94
9.8
52
.9
99
5 9
49
.8
52
.1
65
7 (fa
x)
FBA
En
gin
ee
rin
g
Consulting E
lectrical E
ngineers
fb
ae
ng
r.co
m
FB
A Job N
um
ber:
212.227
Addendum 108/02/191
Addendum 209/04/192
NORTH
OVERALL SITE ELECTRICAL PLAN
SCALE: 1"= 60'
KEY NOTES
EXISTING MV POWER DUCTBANK 3-5"C.
EXISTING MV POWER DUCTBANK 4-5"C.
EXISTING MV POWER DUCTBANK 4-5"C.
EXISTING MV POWER DUCTBANK 4-5"C.
EXISTING MV POWER DUCTBANK 3-5"C.
EXISTING MV POWER DUCTBANK 1-5"C.
EXISTING MV POWER DUCTBANK 3-5"C.
EXISTING 2-5" STUB OUTS.
EXISTING MV POWER DUCTBANK 4-5"C.
EXISTING 2-5" STUB OUTS.
EXISTING MV POWER DUCTBANK 2-5"C.
EXISTING POWER MANHOLE.
NEW DISTRIBUTION SWITCHBOARD.
SEE DETAIL "7" ON SHEET E0.06 FOR EQUIPMENT ANCHORAGE INFORMATION.
DURING THE CONSTRUCTION OF "IB2" STUB-OUT CONDUIT FOR THIS FEEDER.
AFTER DEMOLITION OF BUILDING "D" EXTEND STUB-OUT CONDUIT TO NEW
SWITCHBOARD "NDSB" INSTALL CONDUCTORS AND CONNECT AS REQUIRED.
ES-1.1
OVERALL SITE
ELECTRICAL PLAN
1
#
1
2
3
4
5
6
7
8
9
10
15
14
13
12
11
N
O
R
T
H
BUILDING "C" NEW ELECTRICAL EQUIPMENT PLAN
SCALE: 1/4"= 1'-0"
2
REFER TO DETAIL "5" ON SHEET EQ-1.1 FOR ADDITIONAL INFORMATION.16
PROVIDE 2' X 3' X 4'D. UNDERGROUND PULL BOX WITH BOLT-DOWN TRAFFIC17
SEE SHEET ES-1.0 FOR CONTINUATION.18
GROUND ROD. SEE SHEET E0-0.2A FOR ADDITIONAL INFORMATION.19
20
RATED COVER. ENGRAVE: "POWER".
GROUND WIRE. SEE SHEET E0-0.2A FOR ADDITIONAL INFORMATION.
PULL BOX. SEE SHEET ES-1.0 FOR ADDITIONAL INFORMATION.21
22 UTILIZE 2-3" CONDUITS PER SHEET ES-1.0 FOR EXTENSION OF NEW 480V-3PHASE
FEEDER TO BUILDING "Q".
(E) OFFICE
(E) TRANS.
(E) MECH ROOM
(E) JANT.
ROOM
(E) BUILDING "Q"
2
-
3
-
PQ3
E0-0.2A
(E)
3
6
EE
HSTQ
E0-0.2A
1
NDSB-12
(E) TRANS.
NT.
ROOM
PQ1
E0-0.2A
1
TQ1
E0-0.2A
1
TQ2
E0-0.2A
1
HVQ2
E0-0.2A
1
HVQ1
E0-0.2A
E
(E) FEEDER TO "PQ2"
8
(E) TRANS.
NT.
ROOM
E
PQ1
E0-0.2A
2
5
3
(E) FEEDER TO "PQ2"
QSW-F1
4
-
MCBQ
E0-0.2A
2
QT
E0-0.2A
7
10
MDBH-9
9
DPQ
E0-0.2A
DPQ-2DPQ-3
DPQ-111
QSW-F1
11
T
MDBH-9
9
10" X 4" OPENING
(2) 3" CONDUITS
6"
A
-
48"
91.5"
TRANSFORMER "TC"
DISTRIBUTION
24'X36"X6"D
6"
6"
SWITCHBOARD "NDSB"
24"
50"
24"
800A
WALL
MOUNTED
FUSED SWITCH
36"
24" 48"6"
6"
HOUSEKEEPING PAD
(2) 3" CONDUITS
12"
10" X 4" OPENING
SEE STRUCTURAL 8/S0-1.1
(E) FOOTING
SEE DETAIL "7" ON SHEET S0-1.4
(2) SACK SLURRY PER DETAIL
"7" ON SHEET S0-1.4
(E) EXTERIOR WALL
(E) CONC. SLAB & FOOTING
(E) CONC. SLAB & FOOTING
IN
ST
RU
CT
IO
NA
L B
UIL
DIN
G N
o. 2
CO
MP
TO
N C
OM
MU
NIT
Y C
OL
LE
GE
D
IS
TR
IC
T
11
11
E
. A
RT
ES
IA
B
LV
D. C
OM
PT
ON
, C
A.
file name:
drawn by: checked by:
drawing no.:
drawing of
arch
ite
ctu
re
pla
nn
in
g
in
te
rio
rs
tB
P/A
rch
ite
ctu
re
46
11
T
elle
r A
ve
nu
e
Ne
wp
ort B
ea
ch
, C
A 9
26
60
ph
: 9
49
.6
73
.0
30
0 fx: 9
49
.7
32
.3
89
5
ph: (213) 897-3995
Los Angeles, California. 90012
DIVISION OF STATE ARCHITECT
consultant
agency
owner
date: 04/08/2019
drawing title:
description:date:Rev:
tBP project number :
architect
THIS DRAWING AND THE DESIGNS, DEPICTIONS, IDEAS AND OTHER
INFORMATION CONTAINED HEREIN CONSTITUTE UNPUBLISHED WORK
OF tBP/ARCHITECTURE AND SHALL REMAIN THE PROPERTY OF
tBP/ARCHITECTURE IN PERPETUITY. NO PART THEREOF SHALL BE
REPRODUCED, DISCLOSED, DISTRIBUTED, SOLD, PUBLISHED OR
OTHERWISE USED IN ANY WAY WITHOUT THE ADVANCED EXPRESS
WRITTEN CONSENT OF tBP/ARCHITECTURE.
20998.00
CO
MP
TO
N C
OL
LE
GE
355 South Grand Avenue, Suite 2100
Fax: (213) 897-3159
L
A
C
I
RT
C
E
L
Z
A
J
I
C
E
K
E
S
T
E
P
H
E
N
R.
No. E 10372
E
F
O
R
P
D
E
R
E
T
S
I
G
E
R
A
R
E
E
N
I
G
N
E
L
A
N
O
I
S
S
L
I
F
O
R
N
I
A
S
T
A
T
E
O
F
C
Exp.09-30-20
15
0 P
au
la
rin
o A
ve
nu
e S
uite
A
12
0
Co
sta
M
esa
, C
A 9
26
26
94
9.8
52
.9
99
5 9
49
.8
52
.1
65
7 (fa
x)
FBA
En
gin
ee
rin
g
Consulting E
lectrical E
ngineers
fb
ae
ng
r.co
m
FB
A Job N
um
ber:
212.227
Addendum 108/02/191
Addendum 209/04/192
KEY NOTES
EQ-1.1
BUILDING "Q" PARTIAL
ELECTRICAL PLAN AND
DETAILS
NORTH
BUILDING "Q" PARTIAL ELECTRICAL PLAN
SCALE: 1/4"= 1'-0"
NORTH
ENLARGED TRANS. ROOM DEMO ELECTRICAL PLAN
SCALE: 1/2"= 1'-0"
NORTH
ENLARGED TRANS. ROOM NEW ELECTRICAL PLAN
SCALE: 1/2"= 1'-0"
(E)TRANS. ROOM EAST WALL ELEVATION DETAIL
SCALE: 1/2"= 1'-0"
DISCONNECT AND REMOVE EXISTING ELECTRICAL EQUIPMENT.
PROVIDE 12" X 12" X 4"D. WALL MOUNTED PULL BOX FOR ROUTING
FEEDER.
1
2
INTERCEPT AT EXISTING PANEL AND CONNECT TO NEW FEEDER.
INTERCEPT AT EXISTING FEEDER TO EXISTING PANEL AND CONNECT
TO NEW INCOMING FEEDER.
3
4
SEE DETAIL "1" THIS SHEET FOR CONTINUATION.
DISCONNECT EXISTING CONDUCTOR IN EXISTING UNDERGROUND
CONDUIT.
5
6
1
2
3
4
POWER SERVICE EQUIPMENT ANCHORAGE DETAIL
SCALE: 1"= 1'-0"
5
------------7
EXISTING EQUIPMENT TO REMAIN.8
NEW FEEDER FROM "IB2" ELECTRICAL ROOM.9
INTERCEPT AT EXISTING 2-3" CONDUITS AND EXTEND NEW CONDUCTORS10
SURFACE MOUNTED CONDUIT SECURE TO THE CEILING.11
INTO ELECTRICAL ROOM.
DETAIL - A DETAIL - B
GENERAL NOTES
PENETRATION SHALL FIT IN-BETWEEN THE STUDS
(DO NOT DAMAGE EXISTING STUDS) AND PROVIDE
3 X BLOCKING WITH A/34 TOP AND BOTTOM
(STAGGERED) AROUND THE OPENING.
tBP PROJECT NO: 20998.00 COMPTON COLLEGE ADDENDUM 2 INSTRUCTIONAL BUILDING #2 AUGUST 15, 2019 COMPTON COMMUNITY COLLEGE DISTRICT
CHAIN-LINK FENCE AND GATES 32 31 13 – 1
SECTION 32 31 13 – CHAIN-LINK FENCES AND GATES
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes: Chain-link fences and gates.
B. Related Sections: 1. Section 32 13 13: Cast-in-Place Concrete Paving
1.2 SUBMITTALS
A. Shop Drawings: 1. Submit plans and details indicating extent of fences, locations of gates, and details of attachment
and footings. Indicate means and methods for surface preparation and finishing.
1.3 QUALITY ASSURANCE
A. Comply with Standard Specifications for Public Works Construction, current edition.
1.4 REQUIREMENTS
A. Gates in path of travel must comply with exit door requirements (CBC Section 1003.3.2)
PART 2 - PRODUCTS
2.1 CONCRETE
A. Class 500-C-2500 concrete furnished as prescribed in Section 201-1 "Concrete, Mortar and Related Materials" of the Standard Specifications for Public Works Construction or may be provided in the following volumetric proportions: 1. Portland cement: 1 part 2. Fine aggregate: 2 parts 3. Coarse aggregate (1/4 inch to 1-1/2 inches): 4 parts 4. Water: 7-1/2 gallons, maximum per sack of cement
2.2 CHAIN-LINK FENCE FABRIC
A. Conforming to ASTM A 392, Class C2 zinc coating, 2.00 ounces minimum per square foot of uncoated wire surface, hot-dipped galvanized after weaving, and top and bottom edges knuckled. 1. Fabric for interior fencing shall be 9 gauge woven wire with 2 inch mesh, unless otherwise
specified. Fences 12 feet high or less shall be furnished with single width fabric. 2. Fabric for perimeter fencing shall be 9 gauge woven wire with 1 inch mesh, unless otherwise
specified. Fences 12 feet high or less shall be furnished with single width fabric. 3. Installed fence fabric shall be free from barbs, icicles, or other projections and installed fence
fabric with such defects will be deemed defective Work.
tBP PROJECT NO: 20998.00 COMPTON COLLEGE ADDENDUM 2 INSTRUCTIONAL BUILDING #2 AUGUST 15, 2019 COMPTON COMMUNITY COLLEGE DISTRICT
CHAIN-LINK FENCE AND GATES 32 31 13 – 2
2.3 POSTS, TOP RAILS, BOTTOM RAILS, BRACE RAILS AND GATE FRAMES
A. Posts: Standard weight, galvanized, welded or seamless steel pipe conforming to ASTM A 53, with a minimum yield strength of 35,000 psi.
1. Embed posts into footing 6 inches less than the depth of the footing. Deviations from footing
schedule will require soil test and Architect review.
B. Post Caps: Galvanized iron, ASTM A 47, Grade 32510, designed to fit snugly over posts with a minimum projection of 1-1/2 inches below top of posts. Post caps shall be manufactured with a curved top.
C. Eye Tops: Galvanized iron, ASTM A 47, Grade 32510, designed to fit over line posts, and for through passage of top rail.
D. Expansion Sleeve Couplings for Top Rails: Galvanized, 6 inches long, designed to fit tightly on inside of rail, fitted with raised center.
E. Rail Ends for Top Rails and Brace Rails: Galvanized iron, ASTM A 47, Grade 32510, with holes to receive 3/8 inch bolts for securing to rail end bands.
F. Tension Bands and Bands for Securing Rail Ends: Mild steel flats, at least 1/8 inch x one inch, except tension bands in gates shall be 1/8 inch x 3/4 inch. Bolts for use with tension bands and rail end bands shall be 3/8 inch x 1-1/2 inches.
G. Tension Bars: Mild steel flats at least 3/16 inch x 3/4 inch.
H. Tie Wire: Galvanized ties 6 gauge for fastening fabric to posts, top rails and brace rails. At bottom tension wire 9 gauge galvanized hog rings shall be installed.
I. Finish of Metal Parts: Post caps, couplings, rail ends, tension bands, tension bars, turnbuckles, rivets, bolts, and other metal parts and fittings shall be hot-dipped galvanized after fabrication, except bolts, which may be galvanized or cadmium-plated. Galvanizing shall conform to ASTM A 569, 0.15 percent maximum, and ASTM A 47.
2.4 CHAINLINK FENCE SLATS
A. Chain Link Fence Slats – 8’H Lock-Top Style with horizontal locking strip, PVC, Color to be selected by District.
B. Manufacturer: Hoover Fence Company, 330-358-2335
PART 3 - EXECUTION
3.1 INSTALLATION
A. Install fences to heights indicated on Drawings.
B. Space fence posts at equal intervals between terminal, angle, corner, and gate posts, and not more than 10 feet apart measured from center to center of posts. In curved fence sections having a radius of 50 feet or less, space posts not more than 5 feet - 6 inches apart. Install posts so that top of eye of post caps are level with top of fabric.
tBP PROJECT NO: 20998.00 COMPTON COLLEGE ADDENDUM 2 INSTRUCTIONAL BUILDING #2 AUGUST 15, 2019 COMPTON COMMUNITY COLLEGE DISTRICT
CHAIN-LINK FENCE AND GATES 32 31 13 – 3
C. Install angle or corner posts at each change in direction of 15 degrees or more, at change of 5 percent or more in grade of fencing, and at the beginning and end of curved fence sections.
D. Install terminal posts at ends of runs of fencing. Install gateposts on both sides of driveway and pedestrian gates. For double-leaf gates, net opening between gate posts shall be gate size as indicated on Drawings, plus 3-1/2 inches; for single leaf gates, net opening shall be gate size plus 2-1/2 inches.
E. Where a fence is to be installed on a curb, construct footings with top of footing level with the lower finish grade. Align posts, set plumb and true before placing footings. Remove splattered concrete from exposed pipe surfaces while concrete is still soft. In bituminous surfaced areas, install seal coat on top of concrete footings.
F. Install fences with top and bottom rails. Top and bottom rails shall pass through eye tops and be secured at ends with rail-end fittings and bands.
G. Install fences over 10 feet in height, in addition to top and bottom rails, with a horizontal mid-rail set at mid-height of fence.
H. In fences higher than 10 feet, install brace rails at angles, corners, and terminals at 1/4 and 3/4 of fence height. Provide one horizontal brace rail in panels adjacent to terminal, angle, corner, and gateposts, install at mid-height of fence and rigidly secured to posts with rail end fittings and bands. Provide horizontal brace rails, as specified, in panels of curved sections having a radius of 50 feet or less. Brace rails are not required in fencing 4 feet or less in height.
I. Provide a transom rail and fabric at top of pedestrian gate openings. Install transom rail 6 feet - 8 inches above high point of grade at gate opening. Ends of transom rails shall be pinned or riveted to rail end fittings with 1/4 inch mild steel rivets. Pin or rivet must go through rail and peen. Welding on rail ends is not permitted.
J. Install fence fabric on outward facing side of posts, except for tennis courts. Install fence fabric with top edge projecting above top rail of fence.
K. Install bottom of fence fabric to clear finish grades, except on bituminous surface install 3/4 inch above such surface. Locally shape and trench ground surfaces where necessary to provide uniform top and bottom alignment of fence.
L. Tightly stretch fabric and at terminal, pull corner, angle, and gateposts, secure with tension bars extending full height of fence. Secure tension bars to posts with bolted tension bands spaced not more than 14 inches apart.
M. Bands and Ties: Install bands and ties in accordance with following schedule: 1. 15 bands on 16 feet fence - 6 ties on 16 feet fence 2. 11 bands on 12 feet fence - 2 ties on 12 feet fence 3. 7 bands on 8 feet fence - 7 ties on 8 feet fence 4. 6 bands on 6 feet fence - 6 ties on 6 feet fence 5. 4 bands on 4 feet fence - 4 ties on 4 feet fence
N. Fasten fabric to line posts with wire ties spaced not more than 16 inches apart. Where 6 gauge aluminum ties are furnished, hook the tie at both ends. Installation of hooked ties with links is not permitted.
O. Fasten fabric to top rails, mid-rails, bottom rails, brace rails, with wire ties spaced not more than 18 inches apart. Bend back ends of tie wires so as not to be a hazard. Where 2 fabrics are furnished, lap the
tBP PROJECT NO: 20998.00 COMPTON COLLEGE ADDENDUM 2 INSTRUCTIONAL BUILDING #2 AUGUST 15, 2019 COMPTON COMMUNITY COLLEGE DISTRICT
CHAIN-LINK FENCE AND GATES 32 31 13 – 4
fabrics one mesh at mid-rail and tie both fabrics with 9 gauge wire or 6 gauge aluminum ties to midrails.
P. Field welds shall be cleaned of flux and spatter, damaged galvanizing removed, burrs and projections ground off, properly prepared, then heavily coated with “Galviz” or "Galvabar,” or equal. Install coating in accordance with written recommendations of manufacturer.
Q. Fabrication of Gates: 1. Frames: Fabricate gate frames from steel pipe of size specified, with joints at corners miter cut
and continuously welded to sides. 2. Fabric: Install fence fabric to side members with tension bars and tension bands as specified,
spaced not more than 14 inches apart. Tension bars shall extend full height of gate. Install fence fabric to top and bottom members and to brace rail with wire ties as specified for top rails, spaced not more than 12 inches apart.
3. Latches: Gate latches, and strikes will be furnished by the Contractor. Weld gate latches and strikes to gate posts and frames. Welding shall be performed before gate frames are galvanized, or welds shall be finished as specified for field welds.
4. Hinges: Install and adjust hinges; burr or center punch threads of gate hinge bolts to prevent removal of nuts. Install 3 hinges on each post for swing gates more than 16 feet wide. Grind welds flush and smooth. Hot-dip galvanize fabricated parts after welding, or finish weld as specified for field welds.
5. Gates in path of travel must comply with exit door requirements (CBC Section 1003.3.2) and are to be furnished with panic hardware and kick plates. a. Panic hardware: install per Drawings. b. Kick plates: install per Drawings, at a 3” maximum from paving, on both sides of gate. c. Sign (2.06, this Section) shall be mounted on or adjacent to gate at a height of 60” above
grade.
3.2 FENCING ADJUSTMENTS
A. Where the finish grade is raised 6 inches or less, cut and re-knuckle the existing fence fabric. Adjust tension wire and tie to fabric. Bottom of fence fabric shall be installed ¾” above finish grade.
B. Where the finish pavement is lowered 6 inches or less, demolish the fence footing flush with the finish grade and adjust the fabric and its attachments. Bottom of fence fabric shall be installed ¾” above finish grade.
C. Post footings and fabrics that require readjustment after installation shall be entirely replaced.
3.3 INSTALLATION OF GATES
A. Provide gates of the sizes indicated on Drawings. Allow clearance on gates of 1-1/2 inches at bottom and one inch at top. Construct gates installed in sloping areas to conform to the grade. Provide an opening in each gate for access to locking device or padlock. Knuckle ends of fabric cut for opening to eliminate hazards.
3.4 COMPLETION
A. Completed fencing shall form continuous units between points indicated with required parts, accessories, and fittings provided and installed. Clean exposed metal surfaces of cement, grout and other foreign substances.
tBP PROJECT NO: 20998.00 COMPTON COLLEGE ADDENDUM 2 INSTRUCTIONAL BUILDING #2 AUGUST 15, 2019 COMPTON COMMUNITY COLLEGE DISTRICT
CHAIN-LINK FENCE AND GATES 32 31 13 – 5
B. Fill in holes left by removal of existing fence footings, except in areas where grading Work is indicated or specified, to existing grade with clean earth thoroughly compacted to at least same density as adjoining soil.
3.5 PROTECTION
A. Protect the Work of this section until Substantial Completion.
3.6 CLEANUP
A. Remove rubbish, debris and waste materials and legally dispose of off the Project site.
END OF SECTION 32 31 13