18
At-a-Glance SUSPENSION & FRAMING SYSTEMS TechLine SM 877 ARMSTRONG armstrong.com/suspensionsystems 189 Dimensional Tee Systems INTERLUDE ® , SONATA™ pgs. 195, 202 pg. 196 Slotted Tee Systems SILHOUETTE ® , TRIMLOK ® Exposed Tee Systems PRELUDE XL, PRELUDE ML, SUPRAFINE™ XL & SUPRAFINE ML Concealed Grid System PRELUDE ® pgs. 200-201, 204 Icons are used throughout the catalog to help you quickly identify key product attributes. Fire Resistance Available in fire-resistive options (Fire Guard); tested in specific UL floor/ceiling or roof/ceiling construction design assemblies. Humidity/Corrosion Resistance Identify ceiling performance in different humidity and moisture-related conditions. HumiGuard ® Plus Recommended for areas subject to high humidity, up to standing water. HumiGuard Max Maximum humidity resistance. Chemical Corrosion Seismic Category D, E & F Color Availability Available in color. PeakForm Peaked roof top bulb increases strength for improved performance. Environmental Tee Systems AL PRELUDE PLUS XL, SS PRELUDE PLUS XL, PRELUDE PLUS XL FIRE GUARD PRELUDE XL FOR EXTERIOR Clean Room™ Grid Systems Icon Key pgs. 197, 199, 203 pgs. 193, 198 pg. 194 360° Painted Grid System pgs. 191-192 †† Capping only ††† Peel-off protective film on exposed surfaces to protect from scuffing or marking during installation NOTE: Grid colors to coordinate with Filaments Fabric Panels, MetalWorks Tin, Tincraft Faux Finishes and custom-painted panels are “S” Service items and available upon request. Color Selection Due to printing limitations, shade may vary from actual product. White (WH) Cream (CR) Haze (HA) Camel (CM) Adobe (AD) Oyster (YS) Platinum (PL) Brass (AR) ††† Mirror (AM) ††† Tech Black (BL) Silver Grey (SG) Gun Metal Grey (MY) White Aluminum (WA)†† Copper (CP) Bronze (BZ) Pewter (PW) Silver (SL) Natural Aluminum (WA)†† Silver Satin (SA) Hot Dipped Clear (HDC)

SUSPENSION FRAMING SYSTEMSliterature.puertoricosupplier.com/038/BM37402.pdf · ral 1000 ral 1001* ral 1002 ral 1003 ral 1004 ral 1005 ral 1006 ral 1007* ral 1011 ral 1012 ral 1013*

  • Upload
    others

  • View
    74

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SUSPENSION FRAMING SYSTEMSliterature.puertoricosupplier.com/038/BM37402.pdf · ral 1000 ral 1001* ral 1002 ral 1003 ral 1004 ral 1005 ral 1006 ral 1007* ral 1011 ral 1012 ral 1013*

At-a-Glance

SUSPENSION & FRAMING SYSTEMS

TechLineSM 877 ARMSTRONG armstrong.com/suspensionsystems189

Dimensional Tee SystemsINTERLUDE®, SONATA™

pgs. 195, 202pg. 196

Slotted Tee SystemsSILHOUETTE®, TRIMLOK®

Exposed Tee SystemsPRELUDE XL, PRELUDE ML,SUPRAFINE™ XL & SUPRAFINE ML

Concealed Grid SystemPRELUDE®

pgs. 200-201, 204

Icons are used throughout the catalogto help you quickly identify keyproduct attributes.

Fire ResistanceAvailable in fire-resistive options(Fire Guard); tested in specificUL floor/ceiling or roof/ceilingconstruction design assemblies.

Humidity/Corrosion ResistanceIdentify ceiling performance in differenthumidity and moisture-related conditions.

HumiGuard® PlusRecommended for areassubject to high humidity,up to standing water.

HumiGuard MaxMaximum humidity resistance.

Chemical Corrosion

SeismicCategory D, E & F

Color AvailabilityAvailable in color.

PeakFormPeaked roof top bulb increasesstrength for improved performance.

Environmental Tee SystemsAL PRELUDE PLUS XL,SS PRELUDE PLUS XL,PRELUDE PLUS XL FIRE GUARD™

PRELUDE XL FOR EXTERIOR

Clean Room™ Grid Systems

I c o n K e y

pgs. 197, 199, 203

pgs. 193, 198

pg. 194

360° Painted Grid System

pgs. 191-192

†† Capping only††† Peel-off protective film on exposed surfaces to protect from scuffing or marking during installation

NOTE: Grid colors to coordinate with Filaments Fabric Panels, MetalWorks Tin, Tincraft Faux Finishes and custom-painted panels are “S” Service itemsand available upon request.

Color Selection Due to printing limitations, shade may vary from actual product.

White(WH)

Cream(CR)

Haze(HA)

Camel(CM)

Adobe(AD)

Oyster(YS)

Platinum(PL)

Brass(AR) †††

Mirror(AM) †††

Tech Black(BL)

Silver Grey(SG)

Gun Metal Grey(MY)

WhiteAluminum

(WA)††

Copper(CP)

Bronze(BZ)

Pewter(PW)

Silver(SL)

NaturalAluminum

(WA)††

Silver Satin(SA)

Hot DippedClear (HDC)

Page 2: SUSPENSION FRAMING SYSTEMSliterature.puertoricosupplier.com/038/BM37402.pdf · ral 1000 ral 1001* ral 1002 ral 1003 ral 1004 ral 1005 ral 1006 ral 1007* ral 1011 ral 1012 ral 1013*

SEISMIC PERFORMANCE

TechLineSM 877 ARMSTRONG 190

A l t e r n a t i v e I n s t a l l a t i o n U s i n g B E R C C a t e g o r y C

Suspension Systems

Armstrong Seismic Rx® SuspensionSystem Saves Time and MoneyArmstrong offers an ICC-ES evaluated approach toinstallations (ESR-1308). The Armstrong Seismic RxSuspension System offers a labor and cost-savingmethod of meeting seismic code without risk of delaying your construction schedule.IBC Category C:• Easier to square the system by

attaching to adjoining walls• Tighter, more secure installation• Eliminate stabilizer bars IBC Category D, E, F:• Reduce material costs by using 7/8" molding• Eliminate stabilizer bars• Eliminate installation hassles from 2" wall molding

ICC-ES Recognizes the ArmstrongSeismic Rx Suspension System as a Code Compliant Solution The independent and expert evaluation and confirmationby ICC-ES provides the code official with proven evidencesupporting the Armstrong Seismic Rx Suspension Systemas a code-compliant alternative design to current IBCrequirements.The performance of the Armstrong Seismic RxSuspension System is based on a specific combination of components and method of installation. Othermanufacturer’s components and installation methodswere not tested and are not covered in this evaluation.Substitution of other components puts the system atrisk and is not allowed by this ESR report.

This Icon identifiesArmstrong Seismic Rx Suspension Systems

Category Installation Requirements

A, B Ceiling installation should conform to basic minimums established in ASTM C 636.

C To be installed to CISCA recommendations for areas subject to light to moderate seismic activity.

D, E, F Category D, E and F are to be installed to CISCA andIBC recommendations for areas subject to severeseismic activity.

See armstrong.com/seismic for more on seismic performance.

Armstrong BERC Solution

• Minimum 7/8" wall molding• Grid may be cut tight on two adjoining walls• Minimum 3/8" clearance on two unattached walls• BERC2 on all runners

• Perimeter wires are not needed• Intermediate-duty grid

Solution Benefits

• Meets code requirements• Easy to square up the system• Faster, tighter grid installation• Better overall visual• Eliminates stabilizer bars • Lower cost solution • Better access to the plenum

• Meets code requirements

IBC Requirements

• Minimum 7/8" wall molding• Grid must not be attached to the wall molding• Minimum 3/8" clearance on all sides• Minimum 3/8" overlap of grid on the wall molding• Ends of main beams and cross tees must be tied

together to prevent spreading

• Perimeter wires are not needed• Intermediate-duty grid

BERC Clip

NOTE: Requirements for essential use facilities may be different. Contact TechLine for details.

A l t e r n a t i v e I n s t a l l a t i o n U s i n g B E R C 2 C a t e g o r y D , E , F

Armstrong BERC2 Solution

• Minimum 7/8" wall molding

• Grid must be attached on two adjacent walls –opposite walls require BERC2 with 3/4" clearance(Eliminates the need for pop rivets through the visiblepart of the wall molding)1

• BERC2 clip with 3/4" clearance on unattached ends

• BERC2 maintains main beam and cross tee spacing; no other components required 1

• Heavy-duty systems as identified in ICC-ESR-1308 (refer to Suspension Systems)

Solution Benefits

• Narrow, sleek aesthetic with standard 7/8" wall molding

• Eliminates installation and aesthetic problems associated with 2" wall molding

• BERC2 eliminates visible pop rivets through the wall angle

• Eliminates stabilizer bars • Lower cost solution • Better access to the plenum

• Meets code requirement

IBC Requirements

• Minimum 2" wall molding

• Grid must be attached to two adjacent walls (Pop rivets acceptable)

• Opposite walls must have a 3/4" clearance

• Stabilizer bars to prevent the spread of main beams and cross tees

• Perimeter support wires

• Heavy-duty grid

BERC2 Clip

1 Pop rivets optional on attached walls

Page 3: SUSPENSION FRAMING SYSTEMSliterature.puertoricosupplier.com/038/BM37402.pdf · ral 1000 ral 1001* ral 1002 ral 1003 ral 1004 ral 1005 ral 1006 ral 1007* ral 1011 ral 1012 ral 1013*

360º PAINTEDGrid System

360˚ Painted Grid with 4" AXIOM®-Classic Curved Trim RAL 2002

NOTE: Powder-coated items also available in 9/16 " Suprafine Fire Guard SeismicHanger Hanger Category

Grid Item Spacing* Fire Fire Guard Spacing* Lin. Ft./Face No. Description Dimensions Lbs./Lin. Ft. Guard Item # Lbs./Lin. Ft. Ctn.

360º Painted – Powder Coated Paint 4 Ft. 5 Ft. 4 Ft. 5 Ft.

9/16" 7501 12' HD Main Beam 144 x 9/16 x 1-11/16" 16.86 10.62 – – – – ● 240

15/16" 56418 12' HD Main Beam 144 x 15/16 x 1-11/16" 16.50 8.73 – – – – ● 240

9/16" XL7540✧ 4' Cross Tee 48 x 9/16 x 1-11/16" 10.34 – – – – – – 240

15/16" 56421 4' Cross Tee 48 x 15/16 x 1-11/16" 12.25 – – – – – – 240

9/16" XL7520✧ 2' Cross Tee 24 x 9/16 x 1-11/16" 51.83 – – – – – – 120

15/16" 56419 2' Cross Tee 24 x 15/16 x 1-11/16" 61.33 – – – – – – 120

Molding

7/8" 7800 12' Hemmed Angle Molding 144 x 7/8 x 7/8" – – – – – – – 360

360º Painted – Baked Polyester Paint

15/16" 730136** 12' HD Main Beam 144 x 15/16 x 1-11/16" 16.50 8.73 – – – – ● 240

15/16" XL734036** 4' Cross Tee 48 x 15/16 x 1-11/16" 12.25 – – – – – – 240

15/16" XL732036** 2' Cross Tee 24 x 15/16 x 1-11/16" 61.33 – – – – – – 120

Molding

7/8" 780036** 12' Hemmed Angle Molding 144 x 7/8 x 7/8" – – – – – – – 360

* Simple Span** Items 730136, XL734036, XL732036 and 780036 are available in black and white only with baked polyester paint finish.

Baked polyester paint finish system clips are not painted on main beam or cross tee. Touch-up paint available upon request.✧ Metric items available

ASTM ClassHD - Heavy-dutyID - Intermediate-dutyLD - Light-duty

For more information, see submittal CS-3634.

191 TechLineSM 877 ARMSTRONG armstrong.com/suspensionsystems

V i s u a l S e l e c t i o n P e r f o r m a n c e S e l e c t i o n

MaterialHot dipped galvanized steel

Surface Finish2.0 mil powder-coated painted surfaceor baked polyester paint

Cross Tee/Main Beam InterfaceOverride

End DetailMain Beam: Staked-on clipXL Cross Tee: Staked-on clip

Seismic Performance

Note: Items 56418, 56421 and 56419 are thesame as items 7301, XL7340 and XL8320respectively for seismic performance.

ICC ReportsFor areas under ICC jurisdiction, see ICCevaluation report number ESR-1308 for allowablevalues and/or conditions of use concerning thesuspension system components listed on thispage. The report is subject to reexamination,revisions and possible cancellation.

WarrantySee warranty details in the back of this catalog

P h y s i c a l D a t a

Minimum LBS. to pull outMain Beams compression/tension56418/730136/7501 330.0

Minimum LBS. to pull outCross Tees compression/tensionAll XL cross tees exceed 300 lbs. in compression/tension

Page 4: SUSPENSION FRAMING SYSTEMSliterature.puertoricosupplier.com/038/BM37402.pdf · ral 1000 ral 1001* ral 1002 ral 1003 ral 1004 ral 1005 ral 1006 ral 1007* ral 1011 ral 1012 ral 1013*

360º PAINTEDRecycledContent: 30%

Grid System

RAL 1000 RAL 1001* RAL 1002 RAL 1003 RAL 1004 RAL 1005 RAL 1006 RAL 1007* RAL 1011 RAL 1012 RAL 1013* RAL 1014 RAL 1015*

RAL 1016 RAL 1017 RAL 1018 RAL 1019* RAL 1020 RAL 1021* RAL 1024 RAL 1027 RAL 1028 RAL 1032 RAL 1033 RAL 1034 RAL 2000*

RAL 2001 RAL 2002* RAL 2003 RAL 2004* RAL 2008 RAL 2010 RAL 2011 RAL 2012 RAL 3000* RAL 3001 RAL 3002* RAL 3003 RAL 3004

RAL 3005 RAL 3007 RAL 3009 RAL 3011 RAL 3012 RAL 3013 RAL 3014 RAL 3015 RAL 3016 RAL 3017 RAL 3018 RAL 3022 RAL 3027

RAL 3031 RAL 4001 RAL 4002 RAL 4003 RAL 4004 RAL 4005 RAL 4007 RAL 4008 RAL 4009 RAL 5000 RAL 5001 RAL 5002 RAL 5003*

RAL 5004 RAL 5005 RAL 5007 RAL 5008 RAL 5009* RAL 5010* RAL 5011 RAL 5012* RAL 5013 RAL 5014 RAL 5015* RAL 5018 RAL 5019

RAL 5020 RAL 5021 RAL 5022 RAL 5024 RAL 6000 RAL 6001 RAL 6002 RAL 6003 RAL 6004 RAL 6005 RAL 6006 RAL 6007 RAL 6008

RAL 6009 RAL 6010 RAL 6011* RAL 6012 RAL 6013 RAL 6014 RAL 6015 RAL 6016 RAL 6017 RAL 6018 RAL 6019 RAL 6020 RAL 6021

RAL 6022 RAL 6025 RAL 6026 RAL 6027 RAL 6028 RAL 6029 RAL 6032 RAL 7000 RAL 7001* RAL 7002 RAL 7003 RAL 7004 RAL 7005

RAL 7006 RAL 7008 RAL 7009 RAL 7010 RAL 7011 RAL 7012* RAL 7013 RAL 7015 RAL 7016* RAL 7021* RAL 7022 RAL 7023 RAL 7024

RAL 7026 RAL 7030* RAL 7031* RAL 7032* RAL 7033 RAL 7034 RAL 7035* RAL 7036 RAL 7037 RAL 7038* RAL 7039 RAL 7040* RAL 7044*

RAL 8000 RAL 8001 RAL 8002 RAL 8003 RAL 8004 RAL 8007 RAL 8008 RAL 8011 RAL 8012 RAL 8014* RAL 8015 RAL 8016 RAL 8017

RAL 8019* RAL 8022 RAL 8023 RAL 8024 RAL 8025 RAL 8028 RAL 9001* RAL 9002* RAL 9003* RAL 9004 RAL 9005* RAL 9010* RAL 9011*

RAL 9018* RAL 1023 RAL 2009 RAL 3020 RAL 4006 RAL 5017 RAL 6024 RAL 7042 RAL 7043 RAL 9016* RAL 9017

* These items are also available in matte finish as a special order. ** U.S. and Foreign Patents 6,138,416; 6,523,313; 6,763,642

For actual color selection, request sample of specific colors. Due to printing limitations, shade may vary from actual product.

• Helps to define space in an open/exposedplenum concept

• Provides a structure to hang signage orlights, and create transitions for speakersand HVAC

• 10-year limited warranty• XL** staked-on end detail provides secure

locked connection; easy to remove, re-useand relocate

Ty p i c a l A p p l i c a t i o n s• Retail• Hospitality• Theatres

• PeakForm** patented profileincreases strength and stabilityfor improved performance duringinstallation

• SuperLock** main beam clip is engineeredfor a strong, secure connection and fastaccurate alignment confirmed with anaudible click; easy to remove/relocate

• Hot dipped galvanized coating inhibits redrusting better than electrogalvanized orpainted systems

• 2.0 mil thick powder coating on allcomponents

• Choice of more than 180 colors; matteand gloss finishes

K e y S e l e c t i o n A t t r i b u t e s

360˚ Painted grid

360˚ Painted15/16"

Cross Tee andMain Beam

360˚ Painted9/16"

Cross Tee andMain Beam

15/16"(24mm)

SuspensionSystem

s

192TechLineSM 877 ARMSTRONG

D e t a i l s

Page 5: SUSPENSION FRAMING SYSTEMSliterature.puertoricosupplier.com/038/BM37402.pdf · ral 1000 ral 1001* ral 1002 ral 1003 ral 1004 ral 1005 ral 1006 ral 1007* ral 1011 ral 1012 ral 1013*

D e t a i l s For more information, see submittal CS-3155 (AL PRELUDE PLUS XL) or CS-3154 (SS PRELUDE PLUS XL).

Susp

ensi

on S

yste

ms

V i s u a l S e l e c t i o n P e r f o r m a n c e S e l e c t i o n

Environmental Tee Systems

AL PRELUDE® PLUS XL & SS PRELUDE PLUS XL

193

White Natural StainlessAluminum Aluminum Steel

(WA) (NA) (SS)

AL7200 AL7200 SS7200XLAL7240 XLAL7240 XLSS7240XLAL7220 XLAL7220 XLSS7220

AL7801 AL7801 SS7801

Ty p i c a l A p p l i c a t i o n sAL PRELUDE PLUS XL• Indoor swimming pools with proper

ventilation and hanger wire• Nonmagnetic areas such as

MRI suites• Shower rooms

SS PRELUDE PLUS XL• Food preparation, storage,

manufacturing and packaging areas• Laboratories• Chemical processing• MRI applications

• Seismic Rx® Suspension System savestime and money; Armstrong offers an ICC-ES approach to installations (ESR-1308)

• All systems conform to ASTM C 635 forSevere Environmental Performance

• 10-year warranty; 30-year warranty withHumiGuard® Max products

• Rotary-stitched during manufacture by a patented method** for additional torsional strength and extra stability during installation

• XL** staked-on end detail provides securelocked connection; easy to remove, reuseand relocate

AL PRELUDE PLUS XL• All aluminum for maximum moisture

resistance

SS PRELUDE PLUS XL• Type 304, nonmagnetic, stainless steel;

withstands a wide variety of corrosiveagents

• Peel off protective film on exposed surfaces to prevent scuffing and markingduring installation

K e y S e l e c t i o n A t t r i b u t e s

Fire GuardHanger Hanger

Grid Item Spacing* Fire Fire Guard Spacing* Seismic Lin. Ft./Face No. Description Dimensions Lbs./Lin. Ft. Guard Item # Lbs./Lin. Ft. Category Ctn.

AL Prelude Plus XL 2 Ft. 3 Ft. 4 Ft. 4 Ft. 5 Ft.

15/16" AL7200 12' LD† Main Beam 144 x 15/16 x 1-1/2" – 13.47 6.24 – – – – – 240

15/16" XLAL7240 4' Cross Tee 48 x 15/16 x 1-1/2" – – 6.33 – – – – – 240

15/16" XLAL7220 2' Cross Tee 24 x 15/16 x 1-1/2" 44.45 – – – – – – – 120

Molding

7/8" AL7801 10' Hemmed 120 x 7/8 x 7/8" – – – – – – – – 300Angle Molding

SS Prelude Plus XL

15/16" SS7200 12' ID Main Beam 144 x 15/16 x 1-1/2" – – 12.23 – – – – – 240

15/16" XLSS7240 4' Cross Tee 48 x 15/16 x 1-1/2" – – 10.4 – – – – – 240

15/16" XLSS7220 2' Cross Tee 24 x 15/16 x 1-1/2" 61.66 – – – – – – – 120

Molding

7/8" SS7801 10' Hemmed 120 x 7/8 x 7/8" – – – – – – – – 300Angle Molding

* Simple Span** U.S. and Foreign Patents 5,979,055; 6,763,642† Hanger wire spacing reduced to 36" will provide load capacity of 13.47 lbs./LF

ASTM ClassHD - Heavy-dutyID - Intermediate-dutyLD - Light-duty

AL PRELUDEPLUS XLCross Tee

SS PRELUDEPLUS XLCross Tee

SS PRELUDEPLUS XL

Main Beam

ALPRELUDEPLUS XL

Main Beam

7/8"Hemmed

AngleMolding

C o l o r S e l e c t i o n Due to printing limitations, shade may vary from actual product.

RecycledContent:

TechLineSM 877 ARMSTRONG armstrong.com/suspensionsystems

30% Steel (SS)

25% Aluminum (AL)

Page 6: SUSPENSION FRAMING SYSTEMSliterature.puertoricosupplier.com/038/BM37402.pdf · ral 1000 ral 1001* ral 1002 ral 1003 ral 1004 ral 1005 ral 1006 ral 1007* ral 1011 ral 1012 ral 1013*

D e t a i l s For more information, see submittal CS-3070.

SuspensionSystem

s

V i s u a l S e l e c t i o n P e r f o r m a n c e S e l e c t i o n

Grid System

CLEAN ROOM™

194

White (WH) Unpainted

All Items CHDCXTAC

Fire GuardHanger Hanger

Grid Item Spacing* Fire Fire Guard Spacing* Seismic Lin. Ft./Face No. Description Dimensions Lbs./Lin. Ft. Guard Item # Lbs./Lin. Ft. Category Ctn.

Clean Room Co-Extruded Aluminum (Gasketed)** 2 Ft. 4 Ft. 5 Ft. 4 Ft. 5 Ft.

1-1/2" EA7903 12' ID Main Beam 144 x 1-1/2 x 2" – 14.0 8.4 – – – – – 144

15/16" EA7900 12' ID Main Beam 144 x 15/16 x 1-11/16" – 14.0 – – – – – – 240

1-1/2" EA7947 4' Cross Tee 48 x 1-1/2 x 2" – 18.3 – – – – – – 144

1-1/2" EA7927 2' Cross Tee 24 x 1-1/2 x 2" 48.0 – – – – – – – 72

15/16" EA7940 4' Cross Tee 48 x 15/16 x 1-11/16" – 12.25 – – – – – – 240

15/16" EA7920 2' Cross Tee 24 x 15/16 x 1-11/16" 40.3 – – – – – – – 120

Molding – Gasketed

15/16" EA7801 12' Angle Molding 144 x 15/16 x 15/16" – – – – – – – – 360

Accessories

– CHDC Hold Down Clip – – – – – – – – – 50 pcs

– XTAC Cross Tee Adapter Clip – – – – – – – – – 100 pcs

* Simple Span** U.S. and Foreign Patents 6,701,686

NOTE: Specify light fixtures designed to install with 1-1/2 " face and 2" web height suspension systemswhen using 1-1/2 " face products to allow for fixture maintenance.Compatible Light Fixtures: MANUFACTURER ITEM #

Lithonia CLRM-150 SRT-2x4_F MP4270Guth KLEENSEAL KRT 200Clean Air Solutions CR*-xxx-ESBMorlite CRGHEPA24 Series

Ty p i c a l A p p l i c a t i o n s• Automotive & aerospace• Computer rooms• Hospitals• Food processing facilities• High tech manufacturing• Non-magnetic areas

• System suitable for use in applications upto Class 5 performance per ISO Standard14644-1 (Federal Standard 209E) withoutthe use of hold down clips

• Aluminum construction for maximumcorrosion resistance and non-magneticenvironments

• Lightly textured PVC face, to better matchClean Room VL panels

• Unique, factory applied gaskets for betterseal between panel and grid

• PVC hold down clip to ensure a good sealavailable (not required for clean roomperformance)

• Staked on main beam splice and integralhook cross tee for easy connections andmodule control

• 10-year warranty; 30-year warranty withHumiGuard® Plus products

• For areas under ICC jurisdiction, see ICCevaluation report number ESR-1192

K e y S e l e c t i o n A t t r i b u t e s

ASTM ClassHD - Heavy-dutyID - Intermediate-dutyLD - Light-duty

CLEAN ROOMMain Beam

CLEAN ROOMCross Tee

1-1/2"GasketedAluminumMain Beam

andCross Tee

1-11/16"(43mm)

5/16"(8mm)

15/16"(24mm)

1/4"(6mm)15/16"

GasketedAluminumMain Beam

andCross Tee

Gasketed AluminumAngle Molding

C o l o r S e l e c t i o n Due to printing limitations, shade may vary from actual product.

TechLineSM 877 ARMSTRONG

RecycledContent: 50% Aluminum

Page 7: SUSPENSION FRAMING SYSTEMSliterature.puertoricosupplier.com/038/BM37402.pdf · ral 1000 ral 1001* ral 1002 ral 1003 ral 1004 ral 1005 ral 1006 ral 1007* ral 1011 ral 1012 ral 1013*

D e t a i l s For more information, see submittal CS-3073.

C o l o r S e l e c t i o n Due to printing limitations, shade may vary from actual product.

Note: Additional Interlude XL items for TechZone Integrated Ceiling System are listed in theTechZone Technical Guide (CS-3725). Available online at armstrong.com/techzone

10-YEARAvailability

V i s u a l S e l e c t i o n P e r f o r m a n c e S e l e c t i o n

9/16" Dimensional Tee System

INTERLUDE® XL

195

Fire GuardHanger Hanger

Grid Item Spacing* Fire Fire Guard Spacing* Seismic Lin. Ft./Face No. Description Dimensions Lbs./Lin. Ft. Guard Item # Lbs./Lin. Ft. Category Ctn.

Interlude XL 1 Ft. 2 Ft. 4 Ft. 5 Ft. 4 Ft. 5 Ft.

9/16" 6100 12' ID Main Beam 144 x 9/16 x 1-3/4" – – 12.6 – – – – – – 240

9/16" XL6180 8' Cross Tee 96 x 9/16 x 1-3/4" – – 12.6 – – – – – – 160

9/16" XL6190 6' Cross Tee 72 x 9/16 x 1-3/4" – – 12.6 – – – – – – 120

9/16" XL6140 4' Cross Tee 48 x 9/16 x 1-3/4" – – 12.6 – – – – – – 240

9/16" XL6120 2' Cross Tee 24 x 9/16 x 1-3/4" 66.89 – – – – – – – 120

9/16" XL6110 1' Cross Tee 12 x 9/16 x 1-3/4" 66.89 – – – – – – – – 120

Cross Tees

XL6153 5' Cross Tee 60 x 9/16 x 1-3/4" – – 12.6 – – – – – – 100

XL6152 5' Cross Tee 60 x 9/16 x 1-3/4" – – 12.6 – – – – – – 100

XL6170 30" Cross Tee 30 x 9/16 x 1-3/4" – – – – – – – – – 150

Molding

9/16" 7804 12' Hemmed 144 x 9/16 x 7/8" – – – – – – – – – 360Angle Molding

9/16" 780410 10' Hemmed 120 x 9/16 x 7/8" – – – – – – – – – 300Angle Molding

9/16" 7873 10' Shadow 120 x 9/16 x 15/16 x 3/8" – – – – – – – – – 300Molding

7/8" 7800 12' Hemmed 144 x 7/8 x 7/8" – – – – – – – – – 360Angle Molding

* Simple Span

** U.S. and Foreign Patents 5,979,055; 6,763,642

Ty p i c a l A p p l i c a t i o n s• Offices• Lobbies and corridors• Conference rooms• Retail• Hospitality

• Seismic Rx® Suspension System savestime and money; Armstrong offers an ICC-ES approach to installations (ESR-1308)

• Hot dipped galvanized coating inhibits red rust better than electrogalvanized orpainted systems

• XL** staked-on end detail providessecure locked connection

• Rotary-stitched during manufacture by a patented method** for additional torsional strength and extra stability during installation

• Unmitered intersections for flexibility of cross tee placement

• Accommodates virtually any fixture,especially 1′ x 4′ light fixtures

• 10-year limited warranty; 30-year limited warranty withHumiGuard® Plus products

K e y S e l e c t i o n A t t r i b u t e s

ASTM ClassHD - Heavy-dutyID - Intermediate-dutyLD - Light-duty

White (WH)

INTERLUDE XLMain Beam

INTERLUDE XLCross Tee

9/16"(14mm)

3/16"(5mm)

1-3/4"(44mm)

5/16"(8mm)

13/32"(10mm)

1/4"(6mm)

AngleMolding

INTERLUDE XLMain Beam

ShadowMolding7/8"

(22mm)

9/16"(14mm)

RecycledContent: 30%

TechLineSM 877 ARMSTRONG armstrong.com/suspensionsystems

Susp

ensi

on S

yste

ms

Page 8: SUSPENSION FRAMING SYSTEMSliterature.puertoricosupplier.com/038/BM37402.pdf · ral 1000 ral 1001* ral 1002 ral 1003 ral 1004 ral 1005 ral 1006 ral 1007* ral 1011 ral 1012 ral 1013*

D e t a i l s For more information, see submittal CS-3347.C o l o r S e l e c t i o n Due to printing limitations, shade may vary from actual product.

V i s u a l S e l e c t i o n P e r f o r m a n c e S e l e c t i o n

Tee System

PRELUDE® Concealed

196

• 10-year limited warranty; 30-year withHumiGuard® Plus products

• Rotary-stitched during manufacture by a patented method** for additional torsional strength and extra stability during installation

• Upward access angles for limitedplenum access; use DAC for downwardaccess

Ty p i c a l A p p l i c a t i o n s• Older buildings with minimal

overhead clearance• Seismic Rx® Suspension System saves

time and money; Armstrong offers an ICC-ES approach to installations (ESR-1308)

• PeakForm®** patented profile increases strength and stability for improved performance during installation

• SuperLock™** main beam clip is engineered for a strong, secure connection and fast accurate alignmentconfirmed with an audible click; easy toremove/relocate

• Hot dipped galvanized coating inhibitsred rusting better than electro -galvanized or painted systems

K e y S e l e c t i o n A t t r i b u t e s

Fire Guard SeismicHanger Hanger Category

Grid Item Spacing* Fire Fire Guard Spacing* Lin. Ft./Face No. Description Dimensions Lbs./Lin. Ft. Guard Item # Lbs./Lin. Ft. Ctn.

Prelude Concealed 4 Ft. 5 Ft. 4 Ft. 5 Ft.

15/16" 7301 12' HD Main Beam 144 x 15/16 x 1-11/16" 16.50 8.73 – – – – ● 240

15/16" 7300 12' ID Main Beam 144 x 15/16 x 1-11/16" 12.80 6.35 – – – – – 240

15/16" ML7343 4' Cross Tee 48 x 15/16 x 1-1/2" 9.00 – – – – – – 240

15/16" XL7342 4' Cross Tee 48 x 15/16 x 1-1/2" 9.00 – – – – – – 240

15/16" ML7323 2' Cross Tee 24 x 15/16 x 1-1/2" 38.63 – – – – – – 120

15/16" XL7328 2' Cross Tee 24 x 15/16 x 1-3/8" 38.63 – – – – – – 120

7/16" 7449LE 4' Single Leaf Tee - Left 48 x 7/16 x 1-1/4" – – – – – – – 300

7/16" 7449RI 4' Single Leaf Tee - Right 48 x 7/16 x 1-1/4" – – – – – – – 300

3/4" 7446 4' Tee Spline 48 x 3/4 x 7/8" – – – – – – – 500

3/4" 7436 3' Tee Spline 36 x 3/4 x 7/8" – – – – – – – 375

7/8" 7426 2' Tee Spline 24 x 3/4 x 7/8" – – – – – – – 250

7/16" 7447 4' Concealed Angle 48 x 7/16 x 1-1/4" – – – – – – – 300

7/16" 7437 3' Concealed Angle 36 x 7/16 x 1-1/4" – – – – – – – 300

7/16" 7427 2' Concealed Angle 24 x 7/16 x 1-1/4" – – – – – – – 300

Molding

7/8" 7835 10' Channel Molding 120 x 7/8 x 1-3/4 x 9/16" – – – – – – – 200

15/16" 7830 10' Channel Molding 120 x 15/16 x 1-15/16 x 15/16" – – – – – – – 160

Accessories

– 7445 4' Stabilizer Bar 48" – – – – – – – 400

– 7425 2' Stabilizer Bar 24" – – – – – – – 200

– 7486 Breather Spline 11" – – – – – – – 500 pcs

7/16" 7428 2' Access Hook 24 x 7/16 x 1-1/4" – – – – – – – 300

7/16" 7418 1' Access Hook 12 x 7/16 x 1-1/4" – – – – – – – 300

– 7870 Spring Border Clip – – – – – – – – 1,000 pcs

– DAC Downward Access Clip – – – – – – – – 80 pcs

* Simple Span

** U.S. and Foreign Patents 6,138,416; 6,523,313; 5,979,055; 6,763,642ASTM ClassHD - Heavy-dutyID - Intermediate-dutyLD - Light-duty

PRELUDEConcealed

SystemWhite (WH) Unpainted

7301 7449LE 74457300 7449RI 7425

ML7343 7446 7870XL7342 7436 7428ML7323 7426 7418XL7328 7447 74867835 74377830 7427DAC

TechLineSM 877 ARMSTRONG

RecycledContent: 30%

Suspension Systems

Page 9: SUSPENSION FRAMING SYSTEMSliterature.puertoricosupplier.com/038/BM37402.pdf · ral 1000 ral 1001* ral 1002 ral 1003 ral 1004 ral 1005 ral 1006 ral 1007* ral 1011 ral 1012 ral 1013*

D e t a i l s For more information, see submittal CS-3346.

C o l o r S e l e c t i o n All items are available in white. Due to printing limitations, shade may vary from actual product.

V i s u a l S e l e c t i o n P e r f o r m a n c e S e l e c t i o n

15/16" Exposed Tee System

PRELUDE® ML

197

Fire GuardHanger Hanger

Grid Item Spacing* Fire Fire Guard Spacing* Seismic Lin. Ft./Face No. Description Dimensions Lbs./Lin. Ft. Guard Item # Lbs./Lin. Ft. Category Ctn.

Prelude ML 4 Ft. 5 Ft. 4 Ft. 5 Ft.

15/16" 7301 12' HD Main Beam 144 x 15/16 x 1-11/16" 16.50 8.73 – – – – – 240

15/16" 7300 12' ID Main Beam 144 x 15/16 x 1-11/16" 12.80 6.35 – – – – – 240

15/16" 7302 10' ID Main Beam 120 x 15/16 x 1-11/16" 12.80 6.35 – – – – – 200

15/16" ML7357 5' Cross Tee 60 x 15/16 x 1-1/2" – 7.61 – – – – – 300

15/16" ML7343 4' Cross Tee 48 x 15/16 x 1-1/2" 9.00 – – – – – – 240

15/16" ML7323 2' Cross Tee 24 x 15/16 x 1-1/2" 38.63 – – – – – – 120

15/16" ML7313 1' Cross Tee 12 x 15/16 x 1-1/2" 40.45 – – – – – – 120

Molding

7/8" 7800 12' Hemmed Angle Molding 144 x 7/8 x 7/8" – – – – – – – 360

15/16" 7809 12' Hemmed Angle Molding 144 x 15/16 x 15/16" – – – – – – – 360

7/8" 7835 10' Hemmed Channel Molding 120 x 7/8 x 1-3/4 x 9/16" – – – – – – – 200

* Simple Span

** U.S. and Foreign Patents 6,138,416; 6,523,313; 5,979,055

Ty p i c a l A p p l i c a t i o n s• Retail• Schools• Offices• Hotels and shorefront resorts

• PeakForm®** patented profileincreases strength and stabilityfor improved performanceduring installation

• SuperLock™** main beam clip isengineered for a strong, secureconnection and fast accurate alignmentconfirmed with an audible click;easy to remove/relocate

• Hot dipped galvanized coating inhibits redrusting better than electrogalvanized orpainted systems

• Rotary-stitched during manufacture by apatented method** for additional torsionalstrength and extra stability duringinstallation

• Hook staked-on end detail provides securelocked connection; easy to remove, reuseand relocate

• 10-year limited warranty;30-year with HumiGuard® Plus products

K e y S e l e c t i o n A t t r i b u t e s

ASTM ClassHD - Heavy-dutyID - Intermediate-dutyLD - Light-duty

PRELUDE MLMain Beam

PRELUDE MLCross Tee

PRELUDE MLCross Tee

PRELUDE MLMain Beam

15/16"Hemmed

AngleMolding

White NaturalTech Black Brass Mirror Aluminum Aluminum

Cream (CR) Haze (HA) Camel (CM) Platinum (PL) (BL) (AR)*** (AM)*** (WA) † (NA) †

7301 7301 7301 7301 7301 7301 7301 7301 7301ML7343 ML7343 ML7343 ML7343 ML7343 ML7343 ML7343 ML7343 ML7343ML7323 ML7323 ML7323 ML7323 ML7323 ML7323 ML7323 ML7323 ML7323

7800 7800 7800 7800 7800 7800 7800 7800 7800HD7801 HD7801(Pg. 205) (Pg. 205)

† Capping only

*** Peel-off protective film on exposed surfaces to protect scuffing or marking during installation

RecycledContent: 30%

TechLineSM 877 ARMSTRONG armstrong.com/suspensionsystems

Susp

ensi

onSy

stem

s

Page 10: SUSPENSION FRAMING SYSTEMSliterature.puertoricosupplier.com/038/BM37402.pdf · ral 1000 ral 1001* ral 1002 ral 1003 ral 1004 ral 1005 ral 1006 ral 1007* ral 1011 ral 1012 ral 1013*

PRELUDE® PLUS XL Fire Guard & PRELUDE XL for Exterior Applications

D e t a i l s For more information on PRELUDE PLUS XL Fire Guard, see submittal CS-3156. For more information on PRELUDE XL for Exterior Applications, see submittal CS-3384.

C o l o r S e l e c t i o n Due to printing limitations, shade may vary from actual product.

V i s u a l S e l e c t i o n P e r f o r m a n c e S e l e c t i o n

15/16" Exposed Tee Systems

198

White NaturalAluminum (WA)† Aluminum (NA) †

HD8201 HD8201XL8240 XL8240XL8223 XL8223

7301G90XL7321G90

HD7801 HD7801HD7801G90

PRELUDE XL For Exterior Applications• Main beams, cross tees and

wall molding are minimum G90 hot dipped galvanized steel with pre finished white aluminum capping

• Suitable for wind up-lift applications

Ty p i c a l A p p l i c a t i o n sPRELUDE PLUS XLFire Guard• Locker rooms• Commercial kitchens and food

preparation areas

PRELUDE XL For Exterior Applications• Exterior soffits • Parking garages

• Seismic Rx® Suspension System savestime and money; Armstrong offers an ICC-ES approach to installations (ESR-1308)

• All systems conform to ASTM C 635 forSevere Environmental Performance

• Rotary-stitched during manufacture by a patented method** for additional torsional strength and extra stability during installation

• 10-year limited warranty; 30-year with HumiGuard® Plus or Max products

• XL** staked-on end detail provides securelocked connection; easy to remove, reuseand relocate

PRELUDE PLUS XL Fire Guard™

• PeakForm®** patented profile increases strength and stability for improved performance during installation

• SuperLock™ ** main beam clip is engineered for a strong, secure connection and fast accurate alignmentconfirmed with an audible click; easy toremove/relocate

• Main beams, cross tees and wall moldingare minimum G60 hot dipped galvanizedsteel with prefinished aluminum cappingfor enhanced corrosion resistance

• UL design fire-rated performance

K e y S e l e c t i o n A t t r i b u t e s

Fire Fire Guard SeismicHanger Guard Hanger Category

Grid Item Spacing* Fire Guard Spacing* Lin. Ft./Face No. Description Dimensions Lbs./Lin. Ft. Item # Lbs./Lin. Ft. Ctn.

Prelude Plus XL Fire Guard 4 Ft. 5 Ft. 4 Ft. 5 Ft.

15/16" – 12' HD Main Beam 144 x 15/16 x 1-11/16" – – ● HD8201 16.50 8.73 ● 240

15/16" – 4' Cross Tee 48 x 15/16 x 1-1/2" – – ● XL8240 12.75 – – 240

15/16" – 2' Cross Tee 24 x 15/16 x 1-1/2" – – ● XL8223 38.63 – – 120

Molding

7/8" HD7801 10' Hemmed Angle Molding 120 x 7/8 x 7/8" – – – – – – – 300

Prelude XL for Exterior Applications

15/16" 7301G90 12' HD Main Beam 144 x 15/16 x 1-1/2" 16.50 6.92 – – – – ● 240

15/16" XL7321G90 2' Cross Tee 24 x 15/16 x 1-1/2" 74.38 – – – – – – 120

Molding

7/8" HD7801G90 10' Hemmed 120 x 7/8 x 7/8" – – – – – – – 300Angle Molding

Accessories

BACG90 Bracing Attachment Clip – – – – – – – – 250 pcs

* Simple Span

** U.S. and Foreign Patents 6,138,416; 6,523,313; 5,979,055; 6,763,642ASTM ClassHD - Heavy-dutyID - Intermediate-dutyLD - Light-duty

PRELUDEPLUS XL Main Beam

PRELUDEPLUS XL Cross Tee

PRELUDE PLUS XLFire Guard

Main Beam

PRELUDE XL for ExteriorApplications

Main Beam

7/8" Hemmed Angle Molding

† Capping only

TechLineSM 877 ARMSTRONG

RecycledContent: 30%

Suspension Systems

10-YEARAvailability

Page 11: SUSPENSION FRAMING SYSTEMSliterature.puertoricosupplier.com/038/BM37402.pdf · ral 1000 ral 1001* ral 1002 ral 1003 ral 1004 ral 1005 ral 1006 ral 1007* ral 1011 ral 1012 ral 1013*

RecycledContent: 30%

TechLineSM 877 ARMSTRONG armstrong.com/suspensionsystems

D e t a i l s For more information, see submittal CS-3344.

C o l o r S e l e c t i o n All items are available in white. Due to printing limitations, shade may vary from actual product.

White NaturalBrass Mirror Tech Black Silver Grey Gun Metal Aluminum Aluminum Silver Hot Dipped

Cream (CR) Haze (HA) Camel (CM) Adobe (AD) Oyster (YS) Platinum (PL) (AR)††† (AM)††† (BL) (SG) Grey (MY) (WA) †† (NA) †† Satin (SA) Clear (HDC)

7301 7301 7301 7301 7301 7301 7301 7301 7301 7301 7301 7301 7301 7301 7301XL7342 XL7342 XL7342 XL7342 XL7342 XL7342 XL7342 XL7342 XL7342 XL7342 XL7342 XL7342 XL7342 XL7342 XL7342XL7328 XL7328 XL7328 XL7328 XL7328 XL7328 XL7328 XL7328 XL7328 XL7328 XL7328 XL7328 XL7328 XL7328 XL7328

8300XL8340XL8323

7800 7800 7800 7800 7800 7800 7800 7800 7800 7807, 7808 7807, 7808 7800 7800 HD7801 HD78017807 7835 7835 HD7801 HD7801 (Pg. 205) (Pg. 205)7808 HD7801 HD7801 (Pg. 205) (Pg. 205)

(Pg. 205) (Pg. 205)

Fire Fire Guard SeismicHanger Guard Hanger Category

Grid Item Spacing* Fire Guard Spacing* Lin. Ft./Face No. Description Dimensions Lbs./Lin. Ft. Item # Lbs./Lin. Ft. Ctn.

Prelude XL 4 Ft. 5 Ft. 4 Ft. 5 Ft.

15/16” 7301 12’ HD Main Beam 144 x 15/16 x 1-11/16” 16.50 8.73 ● 8301 16.50 8.73 ● 240

15/16” 7300✧ 12’ ID Main Beam 144 x 15/16 x 1-11/16” 12.80 6.35 ● 8300 12.80 6.35 – 240

15/16” 7305✧ 140” ID Main Beam routs 10” OC 140 x 15/16 x 1-11/16” 12.80 6.35 – – – – – 233

15/16” 7302 10’ ID Main Beam 120 x 15/16 x 1-11/16” 12.80 6.35 – – – – – 200

15/16” XL7380 8’ Cross Tee 96 x 15/16 x 1-11/16” 12.12** – – – – – – 160

15/16” XL7390 6’ Cross Tee 72 x 15/16 x 1-11/16” 12.23*** – – – – – – 120

15/16” XL7357 5’ Cross Tee routs 6" OC 60 x 15/16 x 1-11/16” – 7.61 – – – – – 300

15/16” XL7358✧ 5’ Cross Tee routs 20" OC 60 x 15/16 x 1-11/16” – 7.61 – – – – – 300

15/16” XL7341 4’ Cross Tee 48 x 15/16 x 1-11/16” 16.59 – ● XL8341 16.59 – – 240

15/16” XL7340 4’ Cross Tee 48 x 15/16 x 1-11/16” 12.25 – ● XL8340 12.25 – – 240

15/16” XL7342 4’ Cross Tee 48 x 15/16 x 1-1/2” 9.00 – – – – – 240

15/16” XL7348✧ 4’ Cross Tee 48 x 15/16 x 1-3/8” 8.31 – – – – – – 240

15/16” XL7148 4’ Cross Tee 48 x 15/16 x 1-3/16” 6.00 – – – – – – 240

15/16” XL7330 3’ Cross Tee 36 x 15/16 x 1-11/16” 23.11 – – – – – – 180

15/16” XL7378 30” Cross Tee 30 x 15/16 x 1-3/8” 16.54 – – – – – – 150

15/16” XL7328✧ 2’ Cross Tee 24 x 15/16 x 1-3/8” 40.45 – ● XL8323 40.45 – – 120

15/16” XL7128 2’ Cross Tee 24 x 15/16 x 1-3/16” 33.00 – – – – – – 120

15/16” 2’ Cross Tee 24 x 15/16 x 1-11/16” – – ● XL8320 61.33 – – 120

15/16” XL7368✧ 20” Cross Tee 20 x 15/16 x 1-3/8” 40.45 – – – – – – 100

15/16” XL7318✧ 1’ Cross Tee 12 x 15/16 x 1-3/8” 40.45 – – – – – – 120

Molding7/8” 7800 12’ Hemmed Angle Molding 144 x 7/8 x 7/8” – – – – – – – 360

2” 7808 10 ’ Hemmed Angle Molding 120 x 2 x 2” – – – – – – – 100

2” 780812 12’ Hemmed Angle Molding 144 x 2 x 2" – – – – – – – 120

2” 7807 10 ’ Hemmed Angle Molding 120 x 2 x 1” – – – – – – – 100

* Simple Span ** Hanger Wire Support Mid-Span *** 3' and 6 ' Hanger Spacing information available upon request ✧ Metric items available† U.S. and Foreign Patents

6,138,416; 6,523,313; 5,979,055; 6,763,642

• Rotary-stitched during manufacture by apatented method† for additional torsionalstrength and extra stability during installation

• XL† staked-on end detail provides securelocked connection; easy to remove, reuseand relocate

• Fire Guard™ options offer UL design fire-rated performance

Typica l Appl ica t ions• Retail • Offices• Schools • Hospitality

Note: Additional Prelude XL itemsfor TechZone Integrated CeilingSystem are listed in the TechZoneTechnical Guide (CS-3725). Availableonline at armstrong.com/techzone

• Seismic Rx® Suspension System savestime and money; Armstrong offers an ICC-ES approach to installations (ESR-1308)

• PeakForm® patented profile†

increases strength and stability for improved performance during installation

• SuperLock™ † main beam clip is engineeredfor a strong, secure connection and fastaccurate alignment confirmed with an audible click; easy to remove/relocate

• Hot dipped galvanized coating inhibits redrusting better than electro galvanized orpainted systems

• 10-year limited warranty; 30-year withHumiGuard® Plus products

PRELUDE XLMain Beam

PRELUDE XLCross Tee

PRELUDE XLCross Tee

PRELUDE XLMain Beam

7/8"Hemmed

AngleMolding

1/4" (6mm)

15/16"(24mm)

(43mm)1-11/16"

9/16"(14mm)

ASTM ClassHD - Heavy-dutyID - Intermediate-dutyLD - Light-duty

†† Capping only††† Peel-off protective film on exposed surfaces to protect scuffing or marking during installation

NOTE: Grid colors to coordinate with Filaments Fabric Panels, MetalWorks Tin, Tincraft Faux Finishes and custom painted panels are“S” Service items and available upon request.

Key Se lec t ion A t t r ibu tes

10-YEARAvailability

V i s u a l S e l e c t i o n P e r f o r m a n c e S e l e c t i o n

15/16" Exposed Tee System

PRELUDE® XL

199

Susp

ensi

on S

yste

ms

Page 12: SUSPENSION FRAMING SYSTEMSliterature.puertoricosupplier.com/038/BM37402.pdf · ral 1000 ral 1001* ral 1002 ral 1003 ral 1004 ral 1005 ral 1006 ral 1007* ral 1011 ral 1012 ral 1013*

TechLineSM 877 ARMSTRONG 199A

Detai ls and G r id In te rsec t ion

K e y S e l e c t i o n A t t r i b u t e s

Ty p i c a lA p p l i c a t i o n s

PRELUDE® XL® High Recycled Content (HRC)

PRELUDE XLCross Tee

PRELUDE XLMain Beam

7/8" HemmedAngle Molding

1/4" (6mm)

15/16"(24mm)

(43mm)1-11/16"

9/16"(14mm)

• Rotary-stitched during manufacture by a patented method for additional torsional strength and extra stability during installation

• XL2 staked-on end detail provides secure locked connection; easy to remove, reuse and relocate

• Seismic Rx® Suspension Systems is an ICC-ES approach to seismic installations (ESR-1308)

• PeakForm® patented profileincreases strength and stability for improved performance during installation

• SuperLock™2 main beam clip is engineeredfor a strong, secure connection and fast accurate alignment confirmed with an audible click; easy to remove/relocate

• Hot dipped galvanized coating inhibits redrusting better than electro galvanized orpainted systems

• 10-year limited warranty; 30-year with HumiGuard® Plus products

• Offices• Education• Hospitality• Retail• Healthcare

15/16" Exposed Tee System

C o l o rS e l e c t i o nWhite (WH)

P h y s i c a l D a t a

C r e a t i n g S u s t a i n a b l e C e i l i n g S y s t e m s

MaterialHot dipped galvanized steel made fromUSA produced recycled steel.

Surface FinishBaked polyester paint or anodized

Face Dimension15/16"

ProfileExposed tee

Cross Tee/Main Beam InterfaceOverride

End DetailMain Beam: Staked-on ClipXL Cross Tee: Staked-on Clip

Duty ClassificationHeavy-duty

ASTM C635Heavy-duty main beam classification, commercial quality cold-rolled hot dipped galvanized steel. Exposed surface chemicallycleansed, galvanized capping prefinished in baked polyester or anodized finish.

Seismic PerformanceMain beams – 7301HRCMinimum Lbs. to pull out compression/tension – 335.0

Cross Tee – XL7341HRC, XL8320HRCMinimum Lbs. to pull out compression/tension – all XL cross teesexceed 300 lbs. in both compression and tension.

ICC ReportsFor areas under ICC jurisdiction, see ICC evaluation report number1308 for allowable values and/or conditions of use concerning thesuspension system components listed on this page. The report issubject to re-examination, revisions and possible cancellation.

V i s u a l S e l e c t i o n P e r f o r m a n c e S e l e c t i o n Dots represent highest level of performance.

Hanger Seismic Total TotalGrid Item Spacing* Category Recycled Post-consumer Lin. Ft./Face No. Description Dimensions Lbs./Lin. Ft. Content Content Ctn.

Prelude Main Beam 4 Ft. 5 Ft.

15/16" 7301HRC 12' HD Main Beam 144 x 15/16 x 1-11/16" 16.50 8.73 • 66% 56% 240

Cross Tees15/16" XL7341HRC 4' Cross Tee 48 x 15/16 x 1-11/16" 16.59 - - 66% 56% 240

15/16" XL8320HRC 2' Cross Tee 24 x 15/16 x 1-11/16" 61.33 - - 66% 56% 120

Molding7/8" 7800HRC 12' Hemmed Angle Molding 144 x 7/8 x 7/8" - - - 57% 50% 360

* Simple Span, derive maximum lbs/SF, divide the on-center spacing of the component into the lbs/LF given in the load test data column.

ProductMaterials and Resources Credit 4

100% Recyclable 3 Total Recycled Content 1 LEED RC Value 2

Prelude XL HRC Yes 66% 61

7800HRC Yes 57% 53

1 Recycled content percentage is based on 2008 production. For specific post-consumer and pre-consumer recycled content % breakdown for a project, go to armstrong.com/greengenie.Armstrong adheres to the FTC guidelines for recycled content.

2 LEED® Value (Based on MRc4 calculation). For specific information, go to armstrong.com/greengenie.3 Armstrong Suspension Systems are 100% recyclable where steel products are recycled. Include as part of your construction waste management plan.4 Regional materials calculation available at armstrong.com/greengenie.

L E E D C r e d i t S u m m a r y / S u s t a i n a b i l i t y

Maximize your sustainable ceiling system by combining Prelude XL HRC with the following sustainable ceiling panels:

ULTIMA® HRC Dimensions CIRRUS® HRC Dimensions

1911HRC 2' x 2' x 3/4" 574HRC 2' x 2' x 3/4"1914HRC 2' x 4' x 3/4" 533HRC 2' x 4' x 3/4"

584HRC 2' x 2' x 3/4"535HRC 2' x 4' x 3/4"

LEED® CreditsWaste Recycled Local

Management Content Materials

✔ ✔ ✔Location Dependent

RecycledContent: 57-66%

armstrong.com/greengenie

Suspension Systems

Page 13: SUSPENSION FRAMING SYSTEMSliterature.puertoricosupplier.com/038/BM37402.pdf · ral 1000 ral 1001* ral 1002 ral 1003 ral 1004 ral 1005 ral 1006 ral 1007* ral 1011 ral 1012 ral 1013*

TechLineSM 877 ARMSTRONG

RecycledContent: 30%

D e t a i l s For more information, see submittal CS-3157.

C o l o r S e l e c t i o n Due to printing limitations, shade may vary from actual product.

Typica l Appl ica t ions• Offices• Schools• Retail• Hospitality

• Seismic Rx® Suspension System savestime and money; Armstrong offers an ICC-ES approach to installations (ESR-1308)

• PeakForm® patented profile** increases strength and stability for improved performance during installation

• Hot dipped galvanized coating inhibits redrusting better than electro galvanized or painted systems

• Rotary-stitched during manufacture by apatented method** for additional torsionalstrength and extra stability during installation; maintains size and shape ofreveal when cutting perimeter tees

• XL** staked-on end detail providessecure locked connection

• Available with black reveal • 10-year limited warranty;

30-year when used withHumiGuard® Plus products

Key Se lec t ion A t t r ibu tes

Fire Guard SeismicHanger Hanger Category

Grid Item Spacing* Spacing* Lin. Ft./Face No. Description Notching Dimensions Lbs./Lin. Ft. Lbs./Lin. Ft. Ctn.

Silhouette XL – 1/4" Reveal 4 Ft. 5 Ft. 4 Ft. 5 Ft.

9/16” 7601 12’ HD Main Beam – 144 x 9/16 x 1-3/4” 16.35 7.80 – – ● 240Notched 24" OC

9/16” 7612 12’ HD Main Beam – 144 x 9/16 x 1-3/4” 16.35 7.80 – – ● 240Unnotched

9/16” 7600✧ 12’ ID Main Beam – 144 x 9/16 x 1-3/4” 13.10 6.61 – – – 240Notched 24” OC

9/16” 7602 10’ ID Main Beam – 120 x 9/16 x 1-3/4” 13.10 6.61 – – – 200Notched 24” OC

9/16” 7603 12’ ID Main Beam – 144 x 9/16 x 1-3/4” 13.10 6.61 – – – 240Notched 48” OC

9/16” 7606 10’ ID Main Beam – 120 x 9/16 x 1-3/4” 13.10 6.61 – – – 200Notched 30” OC

9/16” XL7680 8’ Cross Tee – Unnotched 96 x 9/16 x 1-3/4” 12.59 – – – – 160

9/16” XL7690 6’ Cross Tee – Unnotched 72 x 9/16 x 1-3/4” 12.59 – – – – 120

9/16” XL7650 5’ Cross Tee – Unnotched 60 x 9/16 x 1-3/4” – 9.00 – – – 150

9/16” XL7655 5’ Cross Tee – 60 x 9/16 x 1-3/4” – 7.00 – – – 150Center Notched, both sides

9/16” XL7640 4’ Cross Tee - Unnotched 48 x 9/16 x 1-3/4” 13.53 – – – – 240

9/16” XL7645✧ 4’ Cross Tee – 48 x 9/16 x 1-3/4” 12.00 – – – – 240Center Notched, both sides

9/16” XL7646 4’ Cross Tee – 48 x 9/16 x 1-3/4” 13.01 – – – – 240Center Notch, one side

9/16” XL7670 30” Cross Tee - Unnotched 30 x 9/16 x 1-3/4” 39.86 – – – – 150

9/16” XL7620✧ 2’ Cross Tee - Unnotched 24 x 9/16 x 1-3/4” 69.69 – – – – 120

9/16” XL7610 1’ Cross Tee - Unnotched 12 x 9/16 x 1-3/4” 69.69 – – – – 120

Molding9/16” 7804 12’ Hemmed Angle Molding 144 x 9/16 x 7/8” – – – – – 360

9/16” 780410 10’ Hemmed Angle Molding 120 x 9/16 x 7/8” – – – – – 300

9/16” 7873 Shadow Molding 120 x 9/16 x 15/16 x 3/8” – – – – – 300

Accessories– MCC4 1/4” Miter Closure Clip – – – – – – 200 pcs

* Simple Span

** U.S. and Foreign Patents 6,138,416; 5,979,055; 6,763,642✧ Metric items available

ASTM ClassHD - Heavy-dutyID - Intermediate-dutyLD - Light-duty

NOTE: Items 7600, XL7640, XL7645, XL7620 are available with black reveal.

White (WH)

SILHOUETTE XL Main Beam

SILHOUETTE XLCross Tee

AngleMolding

SILHOUETTE XLMain Beam with

1/4" Reveal

ShadowMolding

7/8"(22mm)

9/16"(14mm)

V i s u a l S e l e c t i o n P e r f o r m a n c e S e l e c t i o n

9/16" Bolt-Slot System

SILHOUETTE® XL 1/4" Reveal

200

Suspension Systems

10-YEARAvailability

Page 14: SUSPENSION FRAMING SYSTEMSliterature.puertoricosupplier.com/038/BM37402.pdf · ral 1000 ral 1001* ral 1002 ral 1003 ral 1004 ral 1005 ral 1006 ral 1007* ral 1011 ral 1012 ral 1013*

D e t a i l s For more information, see submittal CS-3078.

10-YEARAvailability

V i s u a l S e l e c t i o n P e r f o r m a n c e S e l e c t i o n

9/16" Bolt-Slot System

SILHOUETTE® XL 1/8" Reveal

201

Fire Guard SeismicHanger Hanger Category

Grid Item Spacing* Spacing* Lin. Ft./Face No. Description Notching Dimensions Lbs./Lin. Ft. Lbs./Lin. Ft. Ctn.

Silhouette XL – 1/8" Reveal 4 Ft. 5 Ft. 4 Ft. 5 Ft.

9/16" 76018 12' HD Main Beam – 144 x 9/16 x 1-3/4" 16.35 7.80 – – ● 240Notched 24" OC

9/16" 76128 12' HD Main Beam – 144 x 9/16 x 1-3/4" 16.35 7.80 – – ● 240Unnotched

9/16" 76008✧ 12' ID Main Beam – 144 x 9/16 x 1-3/4" 13.10 6.61 – – – 240Notched 24" OC

9/16" 76028 10' ID Main Beam – 120 x 9/16 x 1-3/4" 13.10 6.61 – – – 200Notched 24" OC

9/16" 76038 12' ID Main Beam – 144 x 9/16 x 1-3/4" 13.10 6.61 – – – 240Notched 48" OC

9/16" 76068 10' ID Main Beam – 120 x 9/16 x 1-3/4" 13.10 6.61 – – – 200Notched 30" OC

9/16" XL76808 8' Cross Tee – Unnotched 96 x 9/16 x 1-3/4" 12.59 – – – – 160

9/16" XL76908 6' Cross Tee – Unnotched 72 x 9/16 x 1-3/4" 12.59 – – – – 120

9/16" XL76508 5' Cross Tee – Unnotched 60 x 9/16 x 1-3/4" – 9.00 – – – 150

9/16" XL76558 5' Cross Tee – 60 x 9/16 x 1-3/4" – 7.00 – – – 150Center Notched, both sides

9/16" XL76408 4' Cross Tee - Unnotched 48 x 9/16 x 1-3/4" 14.11 – – – – 240

9/16" XL76458✧ 4' Cross Tee – 48 x 9/16 x 1-3/4" 12.00 – – – – 240Center Notched

9/16" XL76468 4' Cross Tee – 48 x 9/16 x 1-3/4" 13.01 – – – – 240Center Notch, one side

9/16" XL76708 30" Cross Tee - Unnotched 30 x 9/16 x 1-3/4" 47.76 – – – – 150

9/16" XL76208✧ 2' Cross Tee - Unnotched 24 x 9/16 x 1-3/4" 69.69 – – – – 120

9/16" XL76108 1' Cross Tee - Unnotched 12 x 9/16 x 1-3/4" 69.69 – – – – 120

Molding9/16" 7804 12' Hemmed Angle Molding 144 x 9/16 x 7/8" – – – – – 360

9/16" 780410 10' Hemmed Angle Molding 120 x 9/16 x 7/8" – – – – – 300

9/16" 7873 Shadow Molding 120 x 9/16 x 15/16 x 3/8" – – – – – 300

Accessories– MCC8 1/8" Miter Closure Clip – – – – – – 200 pcs

* Simple Span

** U.S. and Foreign Patents 6,138,416; 6,523,313; 6,763,642✧ Metric items available

• XL** staked-on end detail provides secure locked connection

• 10-year limited warranty; 30-year when used with HumiGuard® Plus products

Typica l Appl ica t ions• Offices• Schools• Retail• Hospitality

• Seismic Rx® Suspension System savestime and money; Armstrong offers an ICC-ES approach to installations (ESR-1308)

• PeakForm® patented profile** increases strength and stability for improved performance during installation

• Hot dipped galvanized coating inhibits redrusting better than electro galvanized or painted systems

• Rotary-stitched during manufacture by a patented method** for additional torsional strength and extra stability duringinstallation; maintains size and shape ofreveal when cutting perimeter tees

White (WH)

SILHOUETTE XLMain Beam

SILHOUETTE XLCross Tee

ASTM ClassHD - Heavy-dutyID - Intermediate-dutyLD - Light-duty

AngleMolding

SILHOUETTE XLMain Beam with

1/8" Reveal

ShadowMolding

7/8"(22mm)

9/16"(14mm)

Key Se lec t ion A t t r ibu tes

C o l o r S e l e c t i o n Due to printing limitations, shade may vary from actual product.

RecycledContent: 30%

TechLineSM 877 ARMSTRONG armstrong.com/suspensionsystems

Susp

ensi

on S

yste

ms

Page 15: SUSPENSION FRAMING SYSTEMSliterature.puertoricosupplier.com/038/BM37402.pdf · ral 1000 ral 1001* ral 1002 ral 1003 ral 1004 ral 1005 ral 1006 ral 1007* ral 1011 ral 1012 ral 1013*

D e t a i l s For more information, see submittal CS-3209.

C o l o r S e l e c t i o n Due to printing limitations, shade may vary from actual product.

V i s u a l S e l e c t i o n P e r f o r m a n c e S e l e c t i o n

9/16" Dimensional Tee System

SONATA™ XL

2029/16"

(14mm)

3/8"(9mm)

3/16"(5mm)

15/16"(24mm)

Typ ica l Appl ica t ions• Offices• Lobbies and corridors• Conference rooms• Retail• Hospitality

• Seismic Rx® Suspension System savestime and money; Armstrong offers an ICC-ES approach to installations (ESR-1308)

• Co-extruded steel provides crisp edge andprofile detailing and excellent corrosionresistance

• XL** staked-on end detail providessecure locked connection; easy toremove, re-use and relocate

• Accommodates virtually any fixture, especially 1′ x 4′ light fixtures

• 10-year limited warranty; 30-year with HumiGuard® Plus products

• For areas under ICC jurisdiction, see ICC evaluation report numberESR-1192

HangerGrid Item Spacing* Fire Seismic Lin. Ft./Face No. Description Dimensions Lbs./Lin. Ft. Guard Category Ctn.

Sonata 2 Ft. 30" 4 Ft. 5 Ft.

9/16" 6500A✧ 12' ID Main Beam 144 x 9/16 x 1-13/16" – – 12.85 – – – 144

9/16" 6506A 10' ID Main Beam routs 15" OC 120 x 9/16 x 1-13/16" – – 12.85 – – – 120

9/16" XL6560A 5' Cross Tee 60 x 9/16 x 1-13/16" – – – 6.43 – – 180

9/16" XL6540A✧ 4' Cross Tee 48 x 9/16 x 1-13/16" – – 13.75 – – – 144

9/16" XL6530A 30" Cross Tee 30 x 9/16 x 1-13/16" – 30.9 – – – – 90

9/16" XL6520A✧ 2' Cross Tee 24 x 9/16 x 1-13/16" 40.3 – – – – – 72

Molding

9/16" 7821A 12' Shadow Molding 144 x 9/16 x 15/16 x 3/16 x 3/8" – – – – – – 360

* Simple Span

** U.S. and Foreign Patents 6,763,642✧ Metric items available

ASTM ClassHD - Heavy-dutyID - Intermediate-dutyLD - Light-duty

White (WH)All Items

Silver Grey(SG)

All Items

Gun Metal Grey(MY)

All Items

SONATAMain Beam

SONATACross Tee

1/4"(6mm)

13/32"(10mm)

1-13/16"(46mm)

5/16"(8mm)

9/16"(14mm)

SONATAMain Beam

andCross Tee

SONATAShadowMolding

Key Se lec t ion A t t r ibu tes

TechLineSM 877 ARMSTRONG

RecycledContent: 30%

Suspension Systems

Page 16: SUSPENSION FRAMING SYSTEMSliterature.puertoricosupplier.com/038/BM37402.pdf · ral 1000 ral 1001* ral 1002 ral 1003 ral 1004 ral 1005 ral 1006 ral 1007* ral 1011 ral 1012 ral 1013*

D e t a i l s For more information, see submittal CS-3077.

C o l o r S e l e c t i o n All items are available in white. Due to printing limitations, shade may vary from actual product.

Note: Additional Suprafine XL itemsfor TechZone Integrated CeilingSystem are listed in the TechZoneTechnical Guide (CS-3725). Availableonline at armstrong.com/techzone

10-YEARAvailability

V i s u a l S e l e c t i o n P e r f o r m a n c e S e l e c t i o n

9/16" Exposed Tee System

SUPRAFINE® XL and ML

203

Fire Fire Guard SeismicHanger Guard Hanger Category

Grid Item Spacing* Fire Guard Spacing* Lin. Ft./Face No. Description Dimensions Lbs./Lin. Ft. Item # Lbs./Lin. Ft. Ctn.

Suprafine Main Beams 4 Ft. 5 Ft. 4 Ft. 5 Ft.

9/16" 7501 12' HD Main Beam 144 x 9/16 x 1-11/16" 16.86 10.62 – – – – ● 240

9/16" 7500✧ 12' ID Main Beam 144 x 9/16 x 1-11/16" 12.75 5.74 ● 8500 12.75 5.74 – 240

9/16" 7502 10' ID Main Beam 120 x 9/16 x 1-11/16" 12.75 5.74 – – – – – 200

Suprafine XL9/16" XL7580 8' Cross Tee 96 x 9/16 x 1-11/16" 12.73** – – – – – – 160

9/16" XL7590 6' Cross Tee 72 x 9/16 x 1-11/16" 12.73 – – – – – – 120

9/16" XL7558 5' Cross Tee 60 x 9/16 x 1-11/16" – 5.80 – – – – – 300

9/16" XL7540✧ 4' Cross Tee 48 x 9/16 x 1-11/16" 10.34 – ● XL8540 12.74 – – 240

9/16" XL7541 4' Cross Tee 48 x 9/16 x 1-11/16" 12.73 – – – – – – 240

9/16" XL7570 30" Cross Tee 30 x 9/16 x 1-11/16" 28.67 – – – – – – 150

9/16" XL7520✧ 2' Cross Tee 24 x 9/16 x 1-11/16" 51.83 – ● XL8520 58.50 – – 120

9/16" XL7510 1' Cross Tee 12 x 9/16 x 1-11/16" 51.80 – – – – – – 120

Suprafine ML9/16" ML7540 4' Cross Tee 48 x 9/16 x 1-1/2" 10.56 – – – – – – 240

9/16" ML7520 2' Cross Tee 24 x 9/16 x 1-1/2" 34.00 – – – – – – 120

Molding2" 7808 10' Hemmed Angle Molding 120 x 2 x 2" – – – – – – – 100

2" 780812 12' Hemmed Angle Molding 144 x 2 x 2" – – – – – – – 120

9/16" 7804 12' Hemmed Angle Molding 144 x 9/16 x 7/8" – – – – – – – 360

9/16" 780410 10' Hemmed Angle Molding 120 x 9/16 x 7/8" – – – – – – – 300

9/16" 7835 10' Channel Molding 120 x 7/8 x 1-3/4 x 9/16" – – – – – – – 200

9/16" 7873 10' Shadow Molding 120 x 9/16 x 15/16 x 3/8" – – – – – – – 300

9/16" 7874 10' Shadow Molding 120 x 9/16 x 15/16 x 1/4" – – – – – – – 300

* Simple Span ** Hanger Wire Support Mid-Span ✧ Metric items available† U.S. and Foreign Patents

6,138,416; 6,523,313; 5,979,055; 6,763,642

• Cross tees available in XL† (staked-on enddetail) and ML (integral hook end detail);provides secure locked connection; easy toremove, reuse and relocate

• Minimum 1-1/2″ web height keeps components vertical and stable at light fixture interface

• 10-year limited warranty; 30-year withHumiGuard® Plus products

• Fire Guard™ options offer UL design fire-rated performance

Typica l Appl ica t ions• Offices• Schools• Hospitality• Retail• Healthcare

• Seismic Rx® Suspension System savestime and money; Armstrong offers an ICC-ES approach to installations (ESR-1308)

• PeakForm® patented profile†

increases strength and stability for improved performance during installation

• SuperLock™ † main beam clip is engineeredfor a strong, secure connection and fastaccurate alignment confirmed with an audibleclick; easy to remove/relocate

• Hot dipped galvanized coating inhibits redrusting better than electro galvanized orpainted systems

• Rotary-stitched during manufacture by apatented method† for additional torsionalstrength and extra stability during installation

SUPRAFINE XLCross Tee

SUPRAFINE MLCross Tee

SUPRAFINE XLCross Tee

SUPRAFINEMain Beam

Item 787310'

ShadowMolding

1/4"(6mm)

9/16"(14mm)

1-11/16"(43mm)

9/16"(14mm)

ASTM ClassHD - Heavy-dutyID - Intermediate-dutyLD - Light-duty

Brass Mirror Tech Black Silver Grey Gun Metal Silver Hot DippedCream (CR) Haze (HA) Camel (CM) Platinum (PL) (AR)*** (AM)*** (BL) (SG) Grey (MY) Satin (SA) Clear (HDC)

7501 7501 7501 7501 7501 7501 7501 7501 7501 7501 7501XL7540 XL7540 XL7540 XL7540 XL7540 XL7540 XL7540 XL7540 XL7540 XL7540 XL7540XL7520 XL7520 XL7520 XL7520 XL7520 XL7520 XL7520 XL7520 XL7520 XL7520 XL7520

7800 7800 7800 7800 7800 7800 7800 7804 7804 HD7801 HD78017804 7804 7804 7804 7804 7807 7807 (Pg. 205) (Pg. 205)

7808 7808 78087835 7835

HD7801 HD7801(Pg. 205) (Pg. 205)

Key Se lec t ion A t t r ibu tes

*** Peel-off protective film on exposed surfaces to protect scuffing or marking during installation

RecycledContent: 30%

TechLineSM 877 ARMSTRONG armstrong.com/suspensionsystems

Susp

ensi

on S

yste

ms

Page 17: SUSPENSION FRAMING SYSTEMSliterature.puertoricosupplier.com/038/BM37402.pdf · ral 1000 ral 1001* ral 1002 ral 1003 ral 1004 ral 1005 ral 1006 ral 1007* ral 1011 ral 1012 ral 1013*

203ATechLineSM 877 ARMSTRONG

9/16" Exposed Tee System

SUPRAFINE® XL® High Recycled Content (HRC)

K e y S e l e c t i o n A t t r i b u t e s

Ty p i c a lA p p l i c a t i o n s

• XL2 staked-on end detail provides secure locked connection; easy to remove, reuse and relocate

• Minimum 1-11/16" web height keeps components vertical and stable at light fixture interface

• 10-year limited warranty; 30-year with HumiGuard® Plus products

• Seismic Rx® Suspension Systems is an ICC-ES approach to seismic installations (ESR-1308)

• PeakForm® patented profileincreases strength and stability for improved performance during installation

• SuperLock™2 main beam clip is engineeredfor a strong, secure connection and fast accurate alignment confirmed with an audible click; easy to remove/relocate

• Hot dipped galvanized coating inhibits redrusting better than electro galvanized orpainted systems

• Rotary-stitched during manufacture by apatented method for additional torsionalstrength and extra stability during installation

• Offices• Education• Hospitality• Retail• Healthcare

C o l o rS e l e c t i o nWhite (WH)

P h y s i c a l D a t a

V i s u a l S e l e c t i o n P e r f o r m a n c e S e l e c t i o n Dots represent highest level of performance.

MaterialHot dipped galvanized steel made from USA produced recycled steel.

Surface FinishBaked polyester paint or anodized

Face Dimension9/16"

ProfileExposed tee

Cross Tee/Main Beam InterfaceXL – Override

End DetailMain Beam: Staked-on ClipXL Cross Tee: Staked-on Clip

Duty ClassificationHeavy-duty

ASTM C635Heavy-duty main beam classification, commercial quality cold-rolled hot dipped galvanized steel. Exposed surface chemicallycleansed, galvanized capping prefinished in baked polyester oranodized finish.

Seismic PerformanceMain beams – 7501HRCMinimum Lbs. to pull out compression/tension – 335.0

Cross Tee – XL7541HRC, XL7520HRCMinimum Lbs. to pull out compression/tension – 352.0

ICC ReportsFor areas under ICC jurisdiction, see ICC evaluation reportnumber 1308 for allowable values and/or conditions of useconcerning the suspension system components listed on thispage. The report is subject to re-examination, revisions andpossible cancellation.

V i s u a l S e l e c t i o n P e r f o r m a n c e S e l e c t i o nHanger Seismic Total Total

Grid Item Spacing* Category Recycled Post-consumer Lin. Ft./Face No. Description Dimensions Lbs./Lin. Ft. Content Content Ctn.

Suprafine Main Beam 4 Ft. 5 Ft.

9/16" 7501HRC 12' HD Main Beam 144 x 9/16 x 1-11/16" 16.86 10.62 ● 66% 56% 240

Cross Tees9/16" XL7541HRC 4' Cross Tee 48 x 9/16 x 1-11/16" 12.73 – – 66% 56% 240

9/16" XL7520HRC 2' Cross Tee 24 x 9/16 x 1-11/16" 51.83 – – 66% 56% 120

Molding9/16" 7804HRC 12' Hemmed Angle Molding 144 x 9/16 x 7/8" - - - 57% 50% 360

* Simple Span, derive maximum lbs/SF, divide the on-center spacing of the component into the lbs/LF given in the load test data column.

L E E D C r e d i t S u m m a r y / S u s t a i n a b i l i t y

C r e a t i n g S u s t a i n a b l e C e i l i n g S y s t e m s

Maximize your sustainable ceiling system by combining Suprafine XL HRC with the following sustainable ceiling panels:

ULTIMA® HRC Dimensions CIRRUS® HRC Dimensions

1912HRC 2' x 2' x 3/4" 589HRC 2' x 2' x 3/4"1915HRC 2' x 4' x 3/4" 539HRC 2' x 4' x 3/4"

ProductMaterials and Resources Credit 4

100% Recyclable 3 Total Recycled Content 1 LEED RC Value 2

Suprafine XL HRC Yes 66% 61

7804HRC Yes 57% 53

1 Recycled content percentage is based on 2008 production. For specific post-consumer and pre-consumer recycled content % breakdown for a project, go to armstrong.com/greengenie.Armstrong adheres to the FTC guidelines for recycled content.

2 LEED® Value (Based on MRc4 calculation). For specific information, go to armstrong.com/greengenie.3 Armstrong Suspension Systems are 100% recyclable where steel products are recycled. Include as part of your construction waste management plan.4 Regional materials calculation available at armstrong.com/greengenie.

Detai ls and G r id In te rsec t ion

SUPRAFINE XLCross Tee

9/16"Hemmed

Angle Molding

SUPRAFINE XLMain Beam

1/4"(6mm)

9/16"(14mm)

1-11/16"(43mm)

9/16"(14mm)

15/16"(24mm)

9/16"(14mm)

LEED® CreditsWaste Recycled Local

Management Content Materials

✔ ✔ ✔Location Dependent

RecycledContent: 57-66%

armstrong.com/greengenie

Suspension Systems

Page 18: SUSPENSION FRAMING SYSTEMSliterature.puertoricosupplier.com/038/BM37402.pdf · ral 1000 ral 1001* ral 1002 ral 1003 ral 1004 ral 1005 ral 1006 ral 1007* ral 1011 ral 1012 ral 1013*

D e t a i l s

C o l o r S e l e c t i o n Due to printing limitations, shade may vary from actual product.

V i s u a l S e l e c t i o n P e r f o r m a n c e S e l e c t i o n

9/16" Screw-Slot System

TRIMLOK®

204

1"(25mm)

1"(25mm)

1/2"(13mm)

1/2"(13mm)

Typ ica l Appl ica t ions• Offices• Lobbies• Corridors• Conference rooms• MRI Applications

• Threaded screw-slot reveal for easypartition attachment using a 5/16″ –18 N.C. thread screw

• Painted extruded aluminum constructionfor excellent corrosion resistance

• Integral hook-type end detail forsecure locked connection andeasy removability

• 10-year limited warranty; 30-year withHumiGuard® Plus products

Key Select ion At t r ibutes

Fire GuardHanger Hanger

Grid Item Spacing* Fire Fire Guard Spacing* Lin. Ft./Face No. Description Dimensions Lbs./Lin. Ft. Guard Item # Lbs./Lin. Ft. Ctn.

Trimlok Main Beams 4 Ft. 5 Ft. 4 Ft. 5 Ft.

9/16" 2155 12' ID Main Beam 144 x 9/16 x 1-7/8" 12.84 – – – – – 288Notched 24" OC

9/16" 2161 5' Cross Tee 60 x 9/16 x 1-7/8" – – – – – – 240No Notch

9/16" 2156 4' Cross Tee 48 x 9/16 x 1-7/8" 11.01 – – – – – 192Notched Both Sides

9/16" 2157 4' Cross Tee 48 x 9/16 x 1-7/8" 11.01 – – – – – 192No Notch

9/16" 2158 2' Cross Tee 24 x 9/16 x 1-7/8" 73.51 – – – – – 96No Notch

9/16" 2162 20" Bridging Tee 20 x 9/16 x 1-7/8" – – – – – – 80No Notch

9/16" 2163 1' Bridging Tee 12 x 9/16 x 1-7/8" – – – – – – 96

Molding

3/4" 2128 12' Angle Molding 144 x 3/4 x 3/4" – – – – – – 480

1/2" 2129 12' Shadow Molding 144 x 1 x 1 x 1/2" – – – – – – 480

* Simple Span ASTM ClassHD - Heavy-dutyID - Intermediate-dutyLD - Light-duty

White (WH)All Items

TRIMLOKMain Beam

TRIMLOKAngle

Molding

TRIMLOKMain Beam &

Cross Tee

TRIMLOKShadowMolding

3/4"(19mm)

3/4"(19mm)

TechLineSM 877 ARMSTRONG

RecycledContent: 50% Aluminum

SuspensionSystem

s