, HALTON DISTRICT SCHOOL BOARD SURVEY OF ASBESTOS- CONTAINING MATERIALS BROOKDALE PUBLIC SCHOOL 1195 BRIDGE ROAD, OAKVILLE, ONTARIO January 27, 2020 30001072

SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

,

HALTON DISTRICT SCHOOL BOARD

SURVEY OF ASBESTOS-CONTAINING MATERIALS

BROOKDALE PUBLIC SCHOOL

1195 BRIDGE ROAD, OAKVILLE, ONTARIO

January 27, 2020

30001072

Page 2: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

SURVEY OF ASBESTOS-CONTAINING MATERIALS

BROOKDALE PUBLIC SCHOOL

arcadis.com i

SURVEY OF ASBESTOS-CONTAINING MATERIALS

BROOKDALE PUBLIC SCHOOL

1195 Bridge Road, Oakville, Ontario

Prepared for:

Halton District School Board

J.W. Singleton Education Centre

2050 Guelph Line, P.O. Box 5005

Burlington, Ontario

L7P 5A8

Attention: Rudy Hlacar

Prepared by:

Arcadis Canada Inc.

121 Granton Drive, Suite 12

Richmond Hill, Ontario L4B 3N4

Tel 905 764 9380

Our Ref.:

30001072

Date:

January 27, 2020

This document is intended only for the use of

the individual or entity for which it was

prepared and may contain information that is

privileged, confidential and exempt from

disclosure under applicable law. Any

dissemination, distribution or copying of this

document is strictly prohibited.

Shubham Shringi, B.Eng., E.I.T.

Environmental Specialist

Ada Nguyen, B.Sc., CIH

Project Manager, Industrial Hygienist

Page 3: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

SURVEY OF ASBESTOS-CONTAINING MATERIALS

BROOKDALE PUBLIC SCHOOL

arcadis.com ii

CONTENTS

1 INTRODUCTION ................................................................................................................................ 1-1

2 METHODOLOGY ............................................................................................................................... 2-1

2.1 Survey ........................................................................................................................................ 2-1

2.2 Assessment ................................................................................................................................ 2-1

3 SURVEY RESULTS ........................................................................................................................... 3-1

4 DISCUSSION ..................................................................................................................................... 4-1

5 USE AND LIMITATIONS OF THIS REPORT .................................................................................... 5-1

TABLES

Table 1.1 Bulk Material Samples (from O.Reg. 278/05) .................................................................. 1-1

Table 3.1 Summary of Laboratory Analyses of Bulk Samples ......................................................... 3-2

Table 3.2 Summary of Asbestos-Containing Materials ................................................................... 3-9

APPENDICES

Appendix A Floor Plans

Appendix B Laboratory Reports

Appendix C Sample List of Suspect Asbestos-Containing Building Materials from A Guide to

the Regulation Respecting Asbestos on Construction Projects and in Buildings

and Repair Operations

Page 4: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

SURVEY OF ASBESTOS-CONTAINING MATERIALS

BROOKDALE PUBLIC SCHOOL

arcadis.com 1-1

1 INTRODUCTION

Arcadis Canada Inc. (Arcadis) was retained by Halton District School Board to provide an updated survey

of the locations of asbestos-containing materials at Brookdale Public School located at 1195 Bridge Road,

Oakville, Ontario, following the asbestos remediation associated with the renovation project in July and

August 2019.

Asbestos has been widely used in buildings, both in friable applications (materials which can be easily

crumbled such as pipe and tank insulation, sprayed-on fireproofing and acoustic and texture coat

applications) and in non-friable materials such as floor tile, fire-rated ceiling tile, gaskets, cement board,

cement pipe, drywall joint compound and so on. Plaster applications (walls, ceilings, bulkheads, etc.) may

also contain asbestos. The use of asbestos in friable applications was curtailed in Ontario around the

mid-1970s. Most buildings constructed prior to about the mid-1970s contain some form of friable

asbestos-containing material. The use of asbestos in certain non-friable products continued beyond the

1970s. A sample list of suspect asbestos containing building materials is provided in Appendix C.

Control of exposure to asbestos is governed in Ontario by Regulation 278/05 - Designated Substance -

Asbestos on Construction Projects and in Buildings and Repair Operations. Disposal of asbestos waste

(friable and non-friable materials) is governed by Ontario Regulation 278/05 and by Ontario Regulation 347,

Waste Management - General.

The major requirements of O.Reg. 278/05 with respect to asbestos surveys and assessments are as

follows:

follows:

Survey Records:

• non-friable asbestos-containing materials (e.g., vinyl floor tiles, ceiling tiles, drywall joint

compound, plaster, etc.) are to be included in asbestos survey records effective

1 November 2007;

• asbestos survey records are to be updated:

(a) at least once in every 12-month period;

(b) whenever the owner becomes aware of new information; and

• asbestos-containing materials are to be inspected at reasonable intervals in order to

determine their condition.

Bulk Samples:

• the minimum number of bulk samples to be collected from an area of homogeneous

material is set out in Table 1 of the Regulation (Table 1 is reproduced below).

• if analysis establishes that a bulk material sample contains 0.5 per cent or more asbestos

by dry weight:

(a) it is not necessary to analyze other bulk material samples taken from the same

area of homogeneous material; and

(b) the entire area of homogeneous material from which the bulk materials sample

was taken is deemed to be asbestos-containing material.

Page 5: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

SURVEY OF ASBESTOS-CONTAINING MATERIALS

BROOKDALE PUBLIC SCHOOL

arcadis.com 1-2

Table 1.1: Bulk Material Samples (from O.Reg. 278/05)

Item Type of Material Size of Area of Homogeneous

Material

Minimum Number of Bulk Material Samples to be

Collected

1.

Surfacing material, including without limitation material that is applied to surfaces by spraying, by trowelling or otherwise, such as acoustical plaster on ceilings and fireproofing materials on structural members

Less than 90 square metres 3

90 or more square metres, but less than 450 square metres

5

450 or more square metres 7

2. Thermal insulation, except as described in Item 3

Any size 3

3. Thermal insulation patch Less than 2 linear metres or

0.5 square metres 1

4. Other material Any size 3

In practice, application of the Table 1 requirements means that the specified minimum number of negative

(i.e., less than 0.5% asbestos) bulk sample analysis results will be required in order to classify a material

as non asbestos.

Section 10 of O.Reg. 278/05 – Owner’s Responsibility before requesting tender or arranging work – requires

that an owner shall have an investigation carried out in order to determine if materials, that are likely to be

handled, dealt with, disturbed or removed during the alteration of a building, are asbestos-containing and,

if so, whether the asbestos-containing material is friable or non-friable and to identify the type of asbestos

in the material. Section 10 also requires that the owner shall have a report prepared detailing the

investigation findings which is to be provided to any prospective constructor.

Corrective Actions

If asbestos containing fireproofing or acoustical or thermal insulation has fallen and is being disturbed so

that exposure to the material is likely to occur, O.Reg. 278/05 requires that the owner shall cause the fallen

material to be cleaned up and, if it is readily apparent that material will continue to fall because of the

deterioration, the owner shall repair, seal, remove or permanently enclose the material.

O.Reg. 278/05 classifies the asbestos work operations into three types (Type 1, 2 and 3) and specifies

procedures to be followed in conducting asbestos abatement work.

Page 6: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

SURVEY OF ASBESTOS-CONTAINING MATERIALS

BROOKDALE PUBLIC SCHOOL

arcadis.com 2-1

2 METHODOLOGY

2.1 Survey

Site inspections were carried out by Arcadis staff in March 2000 to determine the locations of building

construction materials suspected of containing asbestos. All readily accessible areas, including spaces

above accessible suspended ceilings, were inspected throughout the facility. Site inspections were also

performed in select areas of the building in May 2016, May 2017 and April 2018.

Additional site inspections were performed in select areas of the building in March 2019. This report has

been updated to include information from additional investigations and remediation that took place in 2019.

Representative bulk samples of material were collected by Arcadis staff during the course of the site

inspection and were forwarded to EMSL Analytical Inc. and EMSL Canada Inc. (EMSL) for analysis of

asbestos content. Determination of the locations of asbestos-containing materials were made based on

results of bulk sample analysis, and on visual observations and physical characteristics of the applications

at each inspection location.

2.2 Assessment

During the survey, the condition of all friable materials is assessed. Assessment involves the evaluation of

a number of factors, including:

• asbestos content;

• physical damage;

• water damage;

• accessibility;

• adjacent activity, vibrations;

• air distribution system (air plenum); and

• friability.

Recommendations for appropriate corrective measures are based on findings of the assessment and

consist primarily of either repair or removal (and replacement) of the asbestos containing materials. No

recommended corrective actions were required at the time that this report was prepared.

Page 7: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

SURVEY OF ASBESTOS-CONTAINING MATERIALS

BROOKDALE PUBLIC SCHOOL

arcadis.com 3-1

3 SURVEY RESULTS

Arcadis reviewed reports prepared by Arcadis for the Halton District School Board entitled Revised Pre-

Renovation Designated Substances and Hazardous Materials Survey, Brookdale Public School, 1195

Bridge Road, Oakville, Ontario dated March 4, 2019 and Survey of Asbestos-Containing Materials,

Brookdale Public School, 1195 Bridge Road, Oakville, Ontario dated December 12, 2018.

On the basis of the survey work carried out, we report that friable asbestos containing materials are present

in Brookdale Public School in the following accessible applications:

• thermal insulation applied to pipe fittings and pipe straights above and below ceiling in various

areas throughout the facility.

Asbestos-containing thermal insulation applied to pipe fittings is a grey-coloured cementitious material.

Asbestos-containing thermal insulation applied to pipe straights is “Air-Cell” insulation. “Aircell” is a trade

name for a grey-coloured corrugated paper-like type of pipe insulation, usually found on heating and

domestic hot water piping.

Thermal insulation applied to pipe straights on domestic cold-water lines, sanitary and rainwater piping

observed throughout the facility is comprised of “Anti-sweat” thermal insulation. “Anti-sweat” insulation is

a layered paper-like material, typically brown in colour that may contain intermittent layers of black tar-like

paper and/or intermittent layers of a white paper-like material. The “Anti-sweat” insulation does not contain

asbestos.

Glass fibre insulation is readily visually distinguishable (typically yellow in colour) from asbestos containing

insulation materials and was, therefore, not tested for asbestos content.

All thermal insulation, with the exception of glass fibre material, should be assumed to contain asbestos

unless a bulk sample analysis indicates otherwise.

Visual inspections and laboratory analyses of representative bulk samples of materials confirm that

non-friable asbestos-containing materials are present in the following accessible applications:

• vinyl floor tiles (12” x 12” and 9” x 9”) and associated mastics throughout the facility;

• assumed asbestos-containing cement piping in Rooms 10, 65 and 67;

• concrete block paint application on walls throughout the building constructed in 1983; and

• mortar associated with 6” x 6” ceramic tile baseboard in Room 65.

A room-by-room summary of the locations and conditions of asbestos-containing materials identified is

presented in Table 3.2. The locations of accessible asbestos containing materials are identified on the floor

plans provided in Appendix A.

A summary of the results of laboratory analysis of bulk samples is presented in Table 3.1. The laboratory

reports are provided in Appendix B.

Page 8: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

SURVEY OF ASBESTOS-CONTAINING MATERIALS

BROOKDALE PUBLIC SCHOOL

arcadis.com 3-2

Table 3.1: Summary of Laboratory Analyses of Bulk Samples

Brookdale Public School

Sample No Location Description Asbestos Content

1A Room 21 Black mastic below 9” vinyl floor tiles 3% Chrysotile (1)

2A Room 21 Brown adhesive on 12”x12” ceiling tiles (smooth surface

& uniform holes) None detected (1)

2B Room 48 Brown adhesive on 12”x12” ceiling tiles (smooth surface

& uniform holes) None detected (1)

2C Room 53 Brown adhesive on 12”x12” ceiling tiles (smooth surface

& uniform holes) None detected (1)

3A Room 21 Black vinyl baseboard None detected (PLM) (1) None detected (TEM) (1)

3B Room 71 Black vinyl baseboard None detected (1)

3C Room 72 Black vinyl baseboard None detected (1)

4A Room 21 Brown mastic on black vinyl baseboard None detected (1)

4B Room 72 Brown mastic on black vinyl baseboard None detected (1)

4C Room 71 Brown mastic on black vinyl baseboard None detected (1)

5A Room 22 Brown adhesive on 12”x12” ceiling tiles (small & large

holes) None detected (1)

5B Room 24 Brown adhesive on 12”x12” ceiling tiles (small & large

holes) None detected (1)

5C Room 32 Brown adhesive on 12”x12” ceiling tiles (small & large

holes) None detected (1)

1A Exterior

wall Brick Mortar (1983) None detected (2)

1B Exterior

wall Brick Mortar (1983) None detected (2)

1C Exterior

wall Brick Mortar (1983) None detected (2)

2A Room 65 Mortar (grey) – 6x6” ceramic wall tiles (brown) 1% Chrysotile (2)

3A Room 65 Grout (red) - 6x6” ceramic wall tiles (brown) None detected (2)

3B Room 65 Grout (red) - 6x6” ceramic wall tiles (brown) None detected (2)

3C Room 65 Grout (red) - 6x6” ceramic wall tiles (brown) None detected (2)

Page 9: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

SURVEY OF ASBESTOS-CONTAINING MATERIALS

BROOKDALE PUBLIC SCHOOL

arcadis.com 3-3

Sample No Location Description Asbestos Content

4A Room 78 Mortar- ceramic block wall None detected (2)

4B-Caulking Room 78 Mortar- ceramic block wall None detected (2)

4B-Layer 1 Room 78 Mortar- ceramic block wall None detected (2)

4B-Layer 2 Room 78 Mortar- ceramic block wall None detected (2)

4C Room 78 Mortar- ceramic block wall None detected (2)

5A Exterior

wall Exterior window caulking (brown) None detected (TEM) (2)

5B Exterior

wall Exterior window caulking (brown) None detected (2)

5C Exterior

wall Exterior window caulking (brown) None detected (2)

6A Room 65 Interior window caulking (White) None detected (TEM) (2)

6B Room 65 Interior window caulking (White) None detected (2)

6C Room 65 Interior window caulking (White) None detected (2)

7A Room 65 Mortar – Concrete block wall (1983) None detected (2)

7B Room 65 Mortar – Concrete block wall (1983) None detected (2)

7C Room 65 Mortar – Concrete block wall (1983) None detected (2)

8A-1 Room 78 Paint- Concrete block wall (1958) None detected (2)

8A-2 Room 78 Paint- Concrete block wall (1958) None detected (2)

8A-3 Room 78 Paint- Concrete block wall (1958) None detected (2)

8B Room 65 Paint- Concrete block wall (1983) 1% Chrysotile (2)

1A Room 1 Concrete block filler paint None detected (2)

1B Room 1 Concrete block filler paint None detected (2)

1C Room 1 Concrete block filler paint None detected (2)

1-A Rm.74 Brown adhesive – 12”x12” CT uniform holes None detected (PLM) (2)

None detected (TEM) (2)

1-B Rm.72 Brown adhesive – 12”x12” CT uniform holes None detected (2)

1-C Rm.69 Brown adhesive – 12”x12” CT uniform holes None detected (2)

Page 10: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

SURVEY OF ASBESTOS-CONTAINING MATERIALS

BROOKDALE PUBLIC SCHOOL

arcadis.com 3-4

Sample No Location Description Asbestos Content

2-A Rm.68 Concrete block mortar None detected (PLM) (2)

None detected (TEM) (2)

2-B Rm.77 Concrete block mortar None detected (2)

2-C Rm.69 Concrete block mortar None detected (2)

3-A Rm.27 Brick Mortar (1958) None detected (PLM) (2)

None detected (TEM) (2)

3-B Rm.27 Brick Mortar (1958) None detected (2)

3-C Rm.27 Brick Mortar (1958) None detected (2)

5A Roof Roof membrane None detected (PLM) (2)

None detected (TEM) (2)

5B Roof Roof membrane None detected (2)

5B Roof Roof membrane None detected (2)

6A Roof Kraft paper vapour barrier None detected (PLM) (2)

None detected (TEM) (2)

6B Roof Kraft paper vapour barrier None detected (2)

6C Roof Kraft paper vapour barrier None detected (2)

1-A Room: 49 12” x 12” vinyl floor tile, beige with orange brown

directional streaks.

None detected (PLM) (2)

None detected (TEM) (2)

1-B Room: 47 12” x 12” vinyl floor tile, beige with orange brown

directional streaks. 2% Chrysotile (2)

2-A Room: 49 Mastic, Black on vinyl floor tile. 1.2% Chrysotile (2)

3-A Room: 49 Vinyl baseboard, brown. None detected (PLM) (2)

None detected (TEM) (2)

3-B Room: 51 Vinyl baseboard, brown. None detected (2)

3-C Room: 53 Vinyl baseboard, black. None detected (2)

4-A Room: 49 Mastic, mix of dark and light brown off brown vinyl base

board.

None detected (PLM) (2)

None detected (TEM) (2)

4-B Room: 51 Mastic, mix of dark and light brown off brown vinyl base

board. None detected (2)

4-C Room: 53 Mastic, mix of dark and light brown off black vinyl base

board. None detected (2)

Page 11: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

SURVEY OF ASBESTOS-CONTAINING MATERIALS

BROOKDALE PUBLIC SCHOOL

arcadis.com 3-5

Sample No Location Description Asbestos Content

5-A Room: 53 Cementitious floor tile, terracotta colour. None detected (PLM) (2)

None detected (TEM) (2)

5-B Room: 52 Cementitious floor tile, terracotta colour. None detected (2)

5-C Room: 53 Cementitious floor tile, terracotta colour. None detected (2)

6-A Room: 53 Cement base from Cementitious floor tile None detected (PLM) (2)

None detected (TEM) (2)

6-B Room: 53 Cement base from Cementitious floor tile None detected (2)

6-C Room: 53 Cement base from Cementitious floor tile None detected (2)

7-A Room: 48 12” x 12” vinyl floor tile, light and dark brown with light

and dark flecks

None detected (PLM) (2)

None detected (TEM) (2)

7-B Room: 29 12” x 12” vinyl floor tile, light and dark brown with light

and dark flecks None detected (2)

7-C Room: 25 12” x 12” vinyl floor tile, light and dark brown with light

and dark flecks None detected (2)

8-A Room: 32 12” x 12” vinyl floor tile, white with blue flecks None detected (PLM) (2)

None detected (TEM) (2)

8-B Room: 35 12” x 12” vinyl floor tile, white with blue flecks None detected (2)

8-C Room: 34 12” x 12” vinyl floor tile, white with blue flecks None detected (2)

9-A Room: 36 9” x 9” vinyl floor tile, red with black streaks 2.8% Chrysotile (2)

10-A Room: 29 9” x 9” vinyl floor tile, green/brown/white with cream or

black streaks 1.7% Chrysotile (2)

11-A Room: 21 9” x 9” vinyl floor tile, grey/white with cream or black

streaks 2.1% Chrysotile (2)

12-A Room: 49 Anti-sweat black paper on 4” cold water line. <0.25% Chrysotile

(TEM)(2,3)

12-B Room: 51 Anti-sweat black paper on 4” cold water line. None detected (2)

12-C Room: 55 Anti-sweat black paper on 4” cold water line. <0.25% Chrysotile (2,3)

13-A Room: 49 Horse hair on cold water pipe fitting. 2% Chrysotile (2)

13-B Room: 51 Horse hair on cold water pipe straight 1% Chrysotile (2)

13-C Room: 23 Horse hair on cold water pipe straight None detected (2)

Page 12: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

SURVEY OF ASBESTOS-CONTAINING MATERIALS

BROOKDALE PUBLIC SCHOOL

arcadis.com 3-6

Sample No Location Description Asbestos Content

14-A Room: 49 Caulking, grey, interior window frames. None detected (PLM) (2)

None detected (TEM) (2)

14-B Room: 49 Caulking, grey, interior window frames. None detected (2)

14-C Room:53 Caulking, grey, interior window frames. None detected (2)

15-A Room: 52 Caulking, grey, interior door frame. None detected (PLM) (2)

None detected (TEM) (2)

15-B Room: 52 Caulking, grey, interior door frame. None detected (2)

15-C Room: 55 Caulking, grey, interior door frame. None detected (2)

16-A Room: 50 Ceiling tile mastic, dark brown. None detected (PLM) (2)

None detected (TEM) (2)

16-B Room: 53 Ceiling tile mastic, dark brown. None detected (2)

16-C Room: 53 Ceiling tile mastic, dark brown. None detected (2)

17-A Exterior:

49 Caulking, grey, exterior window frame.

None detected (PLM) (2)

None detected (TEM) (2)

17-B Exterior:

53 Caulking, grey, exterior window frame. None detected (2)

17-C Exterior:

56 Caulking, grey, exterior window frame. None detected (2)

18-A Exterior Caulking on exterior duct on saw dust collector. None detected (PLM) (2)

None detected (TEM) (2)

18-B Exterior Caulking on exterior duct on saw dust collector. None detected (2)

18-C Exterior Caulking on exterior duct on saw dust collector. None detected (2)

19-A Room: 45 Drywall joint compound from wall (1958). None detected (2)

19-B Room: 44 Drywall joint compound from pipe chase (1958) None detected (2)

19-C Room: 40 Drywall joint compound from wall (1958). None detected (2)

19-D Room: 80 Drywall joint compound from wall (1958). None detected (2)

19-E Room: 79 Drywall joint compound from wall (1958). None detected (2)

20-A Room: 9 Drywall joint compound from ceiling patch (1983). None detected (2)

20-B Room: 9 Drywall joint compound from ceiling patch (1983). None detected (2)

20-C Room: 2 Drywall joint compound from wall (1983). None detected (2)

Page 13: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

SURVEY OF ASBESTOS-CONTAINING MATERIALS

BROOKDALE PUBLIC SCHOOL

arcadis.com 3-7

Sample No Location Description Asbestos Content

21-A Room: 23 Plaster, white top coat from ceiling. None detected (2)

21-B Room: 23 Plaster, white top coat from ceiling. None detected (2)

21-C Room: 77 Plaster, white top coat from ceiling. None detected (2)

22-A Room: 23 Plaster, grey bottom coat from ceiling (1958). None detected (2)

22-B Room: 23 Plaster, grey bottom coat from ceiling (1958). None detected (2)

22-C Room: 77 Plaster, grey bottom coat from ceiling (1958). None detected (2)

23-A Room: 7 Plaster, grey coat from ceiling (1983). None detected (2)

23-B Room: 6 Plaster, grey coat from ceiling (1983). None detected (2)

23-C Room: 8 Plaster, grey coat from ceiling (1983). None detected (2)

24-A Room: 49 2’ x 4’ ceiling tile, fissures on 2’ with pinholes. None detected (2)

24-B Room: 58 2’ x 4’ ceiling tile, fissures on 2’ with pinholes. None detected (2)

24-C Room: 59 2’ x 4’ ceiling tile, fissures on 2’ with pinholes. None detected (2)

25-A Room: 50 12” x 12” ceiling tile, large and small holes with wavy

surface. None detected (2)

25-B Room: 54 12” x 12” ceiling tile, large and small holes with wavy

surface. None detected (2)

25-C Room:35 12” x 12” ceiling tile, large and small holes with wavy

surface. None detected (2)

26-A Room: 57 12” x 12” ceiling tile, smooth face. None detected (2)

26-B Room: 53 12” x 12” ceiling tile, smooth face. None detected (2)

26-C Room: 56 12” x 12” ceiling tile, smooth face. None detected (2)

27-A Room: 56 12” x 12” ceiling tile, uniformed holes in straight lines. None detected (2)

27-B Room: 53 12” x 12” ceiling tile, uniformed holes in straight lines. None detected (2)

27-C Room: 71 12” x 12” ceiling tile, uniformed holes in straight lines. None detected (2)

28-A Room: 56 12” x 12” ceiling tile, large and small holes with smooth

surface. None detected (2)

28-B Room: 56 12” x 12” ceiling tile, large and small holes with smooth

surface. None detected (2)

28-C Room: 56 12” x 12” ceiling tile, large and small holes with smooth

surface. None detected (2)

Page 14: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

SURVEY OF ASBESTOS-CONTAINING MATERIALS

BROOKDALE PUBLIC SCHOOL

arcadis.com 3-8

Sample No Location Description Asbestos Content

29-A Room: 60 2’ x 4’ ceiling tile, “L” fissure. None detected (2)

29-B Room: 62 2’ x 4’ ceiling tile, “L” fissure. None detected (2)

29-C Room: 64 2’ x 4’ ceiling tile, “L” fissure. None detected (2)

30-A Room: 42 2’ x 4’ ceiling tile, medium and small pinholes. None detected (2)

30-B Room: 37 2’ x 4’ ceiling tile, medium and small pinholes. None detected (2)

30-C Room: 31 2’ x 4’ ceiling tile, medium and small pinholes. None detected (2)

31-A Room: 25 12” x 12” ceiling tile, medium and small pinholes. None detected (2)

31-B Room: 25 12” x 12” ceiling tile, medium and small pinholes. None detected (2)

31-C Room: 15 12” x 12” ceiling tile, medium and small pinholes. None detected (2)

32 Room: 16 2’ x 4’ ceiling tile, dented fissure with pinholes.

Date code: 09/10/08 None detected (2)

5 Room 23 Rain drain pipe fitting insulation 17% Chrysotile (2)

6 Room 26 Hot water heating pipe straight insulation 22% Chrysotile (2)

7 Room 27 Hot water heating pipe straight insulation 44% Chrysotile (2)

8 Room 27 Hot water heating pipe fitting insulation 44% Chrysotile (2)

9 Room 27 Domestic cold water valve insulation 50% Chrysotile (2)

NOTES:

(1) Sample results derived from a report prepared by Arcadis for the Halton District School Board entitled Revised Pre-Renovation Designated Substances and Hazardous Materials Survey, Brookdale Public School, 1195 Bridge Road, Oakville, Ontario dated March 4, 2019.

(2) Sample results derived from a report prepared by Arcadis for the Halton District School Board entitled Updated Survey of Asbestos-Containing Materials, Brookdale Public School, 1195 Bridge Road, Oakville, Ontario dated December 12, 2018.

(3) “Asbestos-containing material” is defined as material that contains 0.5% or more asbestos by dry weight.

Bulk samples were analyzed by Polarized Light Microscopy (PLM) analysis, except where “TEM” is noted, in which case Transmission Electron Microscopy analysis was also performed.

< = less than.

Chrysotile = Chrysotile asbestos.

Page 15: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

SURVEY OF ASBESTOS-CONTAINING MATERIALS

BROOKDLAE PUBLIC SCHOOL

arcadis.com

3-9

Table 3.2: Summary of Asbestos-Containing Materials

BROOKDALE PUBLIC SCHOOL

Level Room Material Asbestos

Content

Location

Within Space

Estimated

Quantity

Friable or

Non-Friable Condition Comments

1 1 Pipe straight insulation Assumed asbestos Below ceiling 15-30 m Friable G Thermal

insulation too high to access

Pipe fitting insulation Assumed asbestos Below ceiling 5-10 fittings Friable G

Concrete block paint 1 % chrysotile Assumed to be present on walls

10-50 sq. m Non-friable G

1 2 Pipe fitting insulation Assumed asbestos Below ceiling <5 fittings Friable G Thermal

insulation too high to access

12” vinyl floor tiles 2.0% chrysotile Floor 10-50 sq. m Non-friable G

Concrete block paint 1 % chrysotile Assumed to be present on walls

10-50 sq. m Non-friable G

1 3 Concrete block paint 1 % chrysotile Assumed to be present on walls

10-50 sq. m Non-friable G

1 4 Concrete block paint 1 % chrysotile Assumed to be present on walls

10-50 sq. m Non-friable G No access at the

time of the inspections

1 5 12” vinyl floor tiles 2.0% chrysotile Floor 10-50 sq. m Non-friable G

Concrete block paint 1 % chrysotile Assumed to be present on walls

10-50 sq. m Non-friable G

Page 16: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

SURVEY OF ASBESTOS-CONTAINING MATERIALS

BROOKDLAE PUBLIC SCHOOL

arcadis.com

3-10

Level Room Material Asbestos

Content

Location

Within Space

Estimated

Quantity

Friable or

Non-Friable Condition Comments

1 6 Concrete block paint 1 % chrysotile Assumed to be present on walls

10-50 sq. m Non-friable G

1 7 Concrete block paint 1 % chrysotile Assumed to be present on walls

10-50 sq. m Non-friable G

1 8 Concrete block paint 1 % chrysotile Assumed to be present on walls

10-50 sq. m Non-friable G

1 9 Concrete block paint 1 % chrysotile Assumed to be present on walls

10-50 sq. m Non-friable G

1 10 Cement pipe Assumed asbestos Below ceiling 3-15 m Non-friable G

Concrete block paint 1 % chrysotile Assumed to be present on walls

10-50 sq. m Non-friable G

1 12 NACMO

1 13 NACMO

1 14 12” vinyl floor tiles 2.0% chrysotile Floor 50-100 sq. m Non-friable G

Floor tile mastic 1.2% chrysotile Below floor tile 50-100 sq. m Non-friable G

1 15 NAMCO

1 16 NACMO

1 17 NACMO

1 18 NACMO

Page 17: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

SURVEY OF ASBESTOS-CONTAINING MATERIALS

BROOKDLAE PUBLIC SCHOOL

arcadis.com

3-11

Level Room Material Asbestos

Content

Location

Within Space

Estimated

Quantity

Friable or

Non-Friable Condition Comments

1 19 12” vinyl floor tiles 2.0% chrysotile Floor 10-50 sq. m Non-friable G

Floor tile mastic 1.2% chrysotile Below floor tile 10-50 sq. m Non-friable G

1 20 NACMO

1 21 NAMCO

1 22 NACMO

1 23 Pipe fitting insulation 17%-50% Chrysotile Below ceiling <5 fittings Friable G

1 24 NACMO

1 25 12” vinyl floor tiles 2.0% Chrysotile Floor 10-50 sq. m Non-friable G

Floor tile mastic 1.2% chrysotile Below floor tile 10-50 sq. m Non-friable G

1 26 NAMCO

1 27 Pipe fitting insulation 17%-50% Chrysotile Below ceiling 10-20 fittings Friable G

Pipe straight insulation 22%-44% Chrysotile Below ceiling 3-15 m Friable G

1 28 NACMO

1 29 9” vinyl floor tiles 1.7% Chrysotile 70% Floor 10-50 sq. m Non-friable G 12” vinyl floor tiles

do not contain asbestos

Floor tile mastic 3% Chrysotile Below floor tile 10-50 sq. m Non-friable G

1 30 NACMO

Page 18: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

SURVEY OF ASBESTOS-CONTAINING MATERIALS

BROOKDLAE PUBLIC SCHOOL

arcadis.com

3-12

Level Room Material Asbestos

Content

Location

Within Space

Estimated

Quantity

Friable or

Non-Friable Condition Comments

1 31 NACMO

1 32 NACMO

1 33 Pipe fitting insulation 17%-50% Chrysotile Above ceiling <5 fittings Friable G

Pipe straight insulation 22%-44% Chrysotile Above ceiling 3-15 m Friable G

1 34 Pipe fitting insulation 17%-50% Chrysotile Above ceiling <5 fittings Friable G

Pipe straight insulation 22%-44% Chrysotile Above ceiling 3-15 m Friable G

1 35 NACMO

1 36 Pipe straight insulation 22%-44% Chrysotile Below ceiling 3-15 m Friable G

9” vinyl floor tiles 2.8% Chrysotile Floor 10-50 sq. m Non-friable G

1 37 NACMO

1 38 12” vinyl floor tiles 2.0% Chrysotile Floor <10 sq. m Non-friable G

1 39 12” vinyl floor tiles 2.0% Chrysotile Floor 10-50 sq. m Non-friable G

1 40 NACMO

1 41 NACMO

1 42 Pipe fitting insulation 17%-50% Chrysotile Above ceiling <5 fittings Friable G

Pipe straight insulation 22%-44% Chrysotile Above ceiling 3-15 m Friable G

1 43 NACMO

1 44 NACMO

Page 19: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

SURVEY OF ASBESTOS-CONTAINING MATERIALS

BROOKDLAE PUBLIC SCHOOL

arcadis.com

3-13

Level Room Material Asbestos

Content

Location

Within Space

Estimated

Quantity

Friable or

Non-Friable Condition Comments

1 45 NACMO

1 46 Pipe fitting insulation 17%-50% Chrysotile Below ceiling 10-20 fittings Friable G

Pipe straight insulation 22%-44% Chrysotile Below ceiling 3-15 m Friable G

1 46A NACMO

1 47 12” vinyl floor tiles 2.0% Chrysotile Floor 50-100 sq. m Non-friable G

1 47A 12” vinyl floor tiles 2.0% Chrysotile Floor <10 sq. m Non-friable G

1 48 NACMO

1 53 NAMCO

1 54 NACMO

1 55 Pipe fitting insulation 17%-50% Chrysotile Below ceiling 10-20 fittings Friable G

Pipe straight insulation 22%-44% Chrysotile Below ceiling 15-30 m Friable G

1 56 Pipe fitting insulation 17%-50% Chrysotile Above ceiling <5 fittings Friable G

Pipe straight insulation 22%-44% Chrysotile Above and below

ceiling 15-30 m Friable G

1 57 NACMO

1 58 Pipe fitting insulation 17%-50% Chrysotile Above ceiling 5-10 fittings Friable G

Pipe straight insulation 22%-44% Chrysotile Above ceiling 15-30 m Friable G

1 58V NACMO

Page 20: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

SURVEY OF ASBESTOS-CONTAINING MATERIALS

BROOKDLAE PUBLIC SCHOOL

arcadis.com

3-14

Level Room Material Asbestos

Content

Location

Within Space

Estimated

Quantity

Friable or

Non-Friable Condition Comments

1 59 Pipe fitting insulation 17%-50% Chrysotile Above ceiling >20 fittings Friable G

Pipe straight insulation 22%-44% Chrysotile Above ceiling >30 m Friable G

1 60 NACMO

1 61 Pipe fitting insulation 17%-50% Chrysotile Above ceiling >20 fittings Friable G

Pipe straight insulation 22%-44% Chrysotile Above ceiling >30 m Friable G

1 62 NACMO

1 63 NACMO

1 64 Pipe fitting insulation 17%-50% Chrysotile Above ceiling >20 fittings Friable G

Pipe straight insulation 22%-44% Chrysotile Above ceiling >30 m Friable G

1 65 Cement pipe Assumed asbestos Above ceiling 15-30 m Non-friable G

Concrete block paint 1% Chrysotile Block wall 100 sq. m Non-friable G

Ceramic tile mortar 1% Chrysotile Wall tiles (brown) 50 sq. m Non-friable G

1 66 Concrete block paint 1% Chrysotile Assumed to be present on walls

10-50 sq. m Non-friable G

1 67 Cement pipe Assumed asbestos Above ceiling 3-15 m Non-friable G

Concrete block paint 1% Chrysotile Assumed to be present on walls

10-50 sq. m Non-friable G

1 101 NACMO. All

interior finishes renovated in 2013

Page 21: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

SURVEY OF ASBESTOS-CONTAINING MATERIALS

BROOKDLAE PUBLIC SCHOOL

arcadis.com

3-15

Level Room Material Asbestos

Content

Location

Within Space

Estimated

Quantity

Friable or

Non-Friable Condition Comments

1 102 NACMO. All

interior finishes renovated in 2013

1 103 NACMO. All

interior finishes renovated in 2013

1 104 NACMO. All

interior finishes renovated in 2013

1 105 NACMO. All

interior finishes renovated in 2013

2 11 Concrete block paint 1% Chrysotile Assumed to be present on walls

10-50 sq. m Non-friable G

2 68 NAMCO

2 69 NAMCO

2 70 NAMCO

2 71 NAMCO

2 72 NAMCO

2 73 NAMCO

2 74 NAMCO

2 75 NACMO

2 76 NACMO

Page 22: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

SURVEY OF ASBESTOS-CONTAINING MATERIALS

BROOKDLAE PUBLIC SCHOOL

arcadis.com

3-16

Level Room Material Asbestos

Content

Location

Within Space

Estimated

Quantity

Friable or

Non-Friable Condition Comments

2 77 Pipe fitting insulation 17%-50% Chrysotile Below ceiling <5 fittings Friable G

2 78 NACMO

2 79 NACMO

2 80 NACMO

NOTES: < = Less than. > = Greater than. Condition: G = Good. F = Fair. P = Poor. NACMO: No Asbestos-Containing Materials Observed. NOTE!: Asbestos may also be present in locations that are presently inaccessible (e.g., in pipe chases, behind walls, above suspended gypsum board or plaster ceilings,

and below carpets).

Page 23: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

SURVEY OF ASBESTOS-CONTAINING MATERIALS

BROOKDLAE PUBLIC SCHOOL

arcadis.com

4-1

4 DISCUSSION

The owner of a building is required to provide information on the locations of asbestos containing material

to:

i) any person who is an “occupier”(1) of the building. The occupier is then responsible for

providing the information to their own employees;

ii) any prospective constructors, contractors and subcontractors prior to requesting tenders

or arranging for the demolition, alteration or repair of all or part of a building. The

information to be provided shall identify whether any material that is likely to be handled,

dealt with, disturbed or removed is asbestos-containing material; describe the condition of

the material; state whether the material is friable or non-friable; and contain drawings, plans

and specifications, as appropriate, to show the locations of material;

iii) any employer with whom the owner arranges or contracts for work not described in ii) above

that may involve asbestos-containing material or is to be carried out in close proximity to

and may disturb the material;

iv) owner’s staff, if they perform work that involves asbestos-containing material or work that

is to be carried out in close proximity to and may disturb the material.

If material suspected of containing asbestos which is not identified in the asbestos survey records is

discovered during the course of any work in a facility, then either the constructor or the owner is required

to immediately notify (orally and in writing):

a) an inspector at the office of the Ministry of Labour nearest the workplace;

b) the owner;

c) the contractor; and

d) the joint health and safety committee or the health and safety representative.

The owner is also responsible for providing tenderers with a list of designated substances (including

asbestos) at the tendering stage of a project.

This report was prepared as part of the asbestos management program, not for the purposes of construction

or renovation projects. Additional investigation and testing may be required prior to construction or

renovation projects.

Bulk sampling of building materials was carried out in accordance with the minimum sampling requirements

specified in Table 1 of O.Reg. 278/05. We recommend that additional samples of certain types of material

which may have been mixed on site at the time of construction (plaster, drywall joint compound, ceiling

(1) An “occupier” is defined as: (a) a person who is in physical possession of premises, or (b) a person who has responsibility for and control over the condition of premises or the activities carried on there, or

control over persons allowed to enter the premises.

Page 24: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

SURVEY OF ASBESTOS-CONTAINING MATERIALS

BROOKDLAE PUBLIC SCHOOL

arcadis.com

4-2

texture coat, etc.) be tested for asbestos content prior to the disturbance of these materials at the time of

renovations, alterations or demolition work.

Asbestos may also be present in materials which were not sampled during the course of the asbestos

survey carried out by Arcadis, including, but not limited to, roofing materials, fire doors, mastics or

cementitious levelling compound under vinyl flooring, acoustic ceiling tile adhesive, grout, caulking, gaskets

in piping, internal components of boilers, paints and coatings, components of electrical equipment, (e.g. –

electrical wiring insulation, non-metallic sheathed cable, electrical panel partitions, arc chutes, high-grade

electrical paper, etc.), concrete, etc., and/or in locations that are presently inaccessible (e.g., in pipe chases,

behind walls, above suspended gypsum board or plaster ceilings, and below carpets). Asbestos may also

be present in the form of vermiculite insulation in cavities in concrete or cement block walls (used as in-fill

insulation). Confirmatory testing of any such materials could be undertaken as the need arises (i.e., at the

time of renovations, modifications or demolition) or the materials can be assumed to contain asbestos

based on findings in adjacent areas.

As noted above, if any materials which may contain asbestos and which were not tested during the course

of the asbestos survey are discovered during any construction activities, the work shall not proceed until

such time as the required notifications have been made and an appropriate course of action is determined.

Page 25: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

SURVEY OF ASBESTOS-CONTAINING MATERIALS

BROOKDLAE PUBLIC SCHOOL

arcadis.com

5-1

5 USE AND LIMITATIONS OF THIS REPORT

This report, prepared for the Halton District School Board, does not provide certification or warranty,

expressed or implied, that the investigation conducted by Arcadis identified all asbestos-containing

materials present in the subject facilities. The work undertaken by Arcadis was directed to provide

information on the presence of asbestos-containing building materials based on visual inspection of readily

accessible areas of the building and on the results of laboratory analysis of bulk samples of material

gathered in the course of the visual inspection. The survey did not include for identification of asbestos in

process materials, equipment (including electrical equipment and wiring), furniture (e.g., chairs, table tops,

chalkboards, etc.), nor material outside of the building (e.g. asphaltic pavement).

This report was prepared by Arcadis for the Halton District School Board. Any use which a third party

makes of the report, or reliance on, or decisions to be based on it, is the responsibility of such third parties.

Page 26: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

APPENDIX A Floor Plans

Page 27: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

ASBESTOS-CONTAINING PAINT ON

CONCRETE BLOCK WALLS MAY BE

PRESENT THROUGHOUT THE BUILDING

CONSTRUCTED IN 1983.

NOTES:

LEGEND:

FUNCTIONAL SPACE

THROUGHOUT FUNCTIONAL SPACE

ABOVE CEILING ASSEMBLY

ASBESTOS ON PIPING (FRIABLE)

ASBESTOS ON PIPE FITTINGS ONLY

(FRIABLE)

ASBESTOS CEMENT PRODUCT

(NON-FRIABLE)

ASBESTOS VINYL FLOOR TILE

(NON-FRIABLE)

ASBESTOS FLOOR TILE MASTIC

(NON-FRIABLE)

ASBESTOS MORTAR BED UNDER

CERAMIC TILES (NON-FRIABLE)

ASBESTOS PAINT (NON-FRIABLE)

1. INTERIORS OF ALL FIRE DOORS ARE

ASSUMED TO CONTAIN ASBESTOS.

N.T.S

G.E.C. A.N.

Drawn By:

Date:

Scale:

REVISIONS:

No. Date: By: Revisions

REFERENCE:

1.

Approved By:

Drawing No:

Project No:

JAN. 2020

30001072-1

HALTON DISTRICT SCHOOL BOARD

LOCATIONS OF ASBESTOS-CONTAINING

MATERIALS

BROOKDALE PUBLIC SCHOOL

1195 BRIDGE ROAD, OAKVILLE, ON

FIRST FLOOR

30001072

Page 28: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

ASBESTOS-CONTAINING PAINT ON

CONCRETE BLOCK WALLS MAY BE

PRESENT THROUGHOUT THE BUILDING

CONSTRUCTED IN 1983.

N.T.S

G.E.C. A.N.

Drawn By:

Date:

Scale:

NOTES:

REVISIONS:

No. Date: By: Revisions

REFERENCE:

1.

Approved By:

Drawing No:

Project No:

LEGEND:

FUNCTIONAL SPACE

THROUGHOUT FUNCTIONAL SPACE

ABOVE CEILING ASSEMBLY

ASBESTOS ON PIPE FITTINGS ONLY

(FRIABLE)

JAN. 2020

30001072-2

1. INTERIORS OF ALL FIRE DOORS ARE

ASSUMED TO CONTAIN ASBESTOS.

30001072

HALTON DISTRICT SCHOOL BOARD

LOCATIONS OF ASBESTOS-CONTAINING

MATERIALS

BROOKDALE PUBLIC SCHOOL

1195 BRIDGE ROAD, OAKVILLE, ON

SECOND FLOOR

Page 29: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and
Page 30: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and
Page 31: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

APPENDIX B Laboratory Reports

Page 32: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551803844

702170-148

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Attn:

Proj: BROOKDALE PS/702170-148

Phone: (905) 882-5984

Fax: (905) 882-8962

Collected:

Received: 4/06/2018

Analyzed: 4/17/2018

Amit Kaul

ARCADIS Canada Inc.

121 Granton Drive

Unit 12

Richmond Hill, ON L4B 3N4

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551803844-00011A

Exterior wall/Brick Mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/13/2018 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551803844-00021B

Exterior wall/Brick Mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/13/2018 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551803844-00031C

Exterior wall/Brick Mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/13/2018 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551803844-00042A

Room 65/Mortar (grey) - 6x6" ceramic wall tiles (brown)

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/13/2018 0% 99% 1% ChrysotilePLM Gray

Client Sample ID:

Sample Description:

Lab Sample ID: 551803844-00052B

Room 65/Mortar (grey) - 6x6" ceramic wall tiles (brown)

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/13/2018PLM Positive Stop (Not Analyzed)

Client Sample ID:

Sample Description:

Lab Sample ID: 551803844-00062C

Room 65/Mortar (grey) - 6x6" ceramic wall tiles (brown)

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/13/2018PLM Positive Stop (Not Analyzed)

Client Sample ID:

Sample Description:

Lab Sample ID: 551803844-00073A

Room 65/Grout (red) - 6x6" ceramic wall tiles (brown)

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/13/2018 8% 92%PLM Brown None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 4/17/2018 03:53PM Page 1 of 5

Page 33: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551803844

702170-148

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551803844-00083B

Room 65/Grout (red) - 6x6" ceramic wall tiles (brown)

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/13/2018 8% 92%PLM Brown None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551803844-00093C

Room 65/Grout (red) - 6x6" ceramic wall tiles (brown)

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/13/2018 8% 92%PLM Brown ce4None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551803844-00104A

Room 78/Mortar- ceramic block wall

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/13/2018 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551803844-00114B-Caulking

Room 78/Mortar- ceramic block wall

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/13/2018 5% 95%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551803844-0011A4B-Layer 1

Room 78/Mortar- ceramic block wall

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/13/2018 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551803844-0011B4B-Layer 2

Room 78/Mortar- ceramic block wall

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/13/2018 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551803844-00124C

Room 78/Mortar- ceramic block wall

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/13/2018 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551803844-00135A

Exterior wall/Exterior window caulking (brown)

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/13/2018 0.0% 100%PLM Grav. Reduction None DetectedBlack

4/13/2018 0.0% 100%TEM Grav. Reduction None DetectedBlack

Test Report:EPAMultiTests-7.32.2.D Printed: 4/17/2018 03:53PM Page 2 of 5

Page 34: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551803844

702170-148

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551803844-00145B

Exterior wall/Exterior window caulking (brown)

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/13/2018 5% 95%PLM Brown None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551803844-00155C

Exterior wall/Exterior window caulking (brown)

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/13/2018 5% 95%PLM Brown None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551803844-00166A

Room 65/Interior window caulking (White)

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/13/2018 0.0% 100%PLM Grav. Reduction None DetectedWhite

4/13/2018 0.0% 100%TEM Grav. Reduction None DetectedWhite

Client Sample ID:

Sample Description:

Lab Sample ID: 551803844-00176B

Room 65/Interior window caulking (White)

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/13/2018 5% 95%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551803844-00186C

Room 65/Interior window caulking (White)

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/13/2018 5% 95%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551803844-00197A

Room 65/Mortar- Concrete block wall

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/13/2018 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551803844-0019A7B

Room 65/Mortar- Concrete block wall

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/17/2018 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551803844-0019B7C

Room 65/Mortar- Concrete block wall

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/17/2018 0% 100%PLM Gray None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 4/17/2018 03:53PM Page 3 of 5

Page 35: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551803844

702170-148

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551803844-00208A-1

Room 78/Paint- Concrete block wall

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/13/2018 0% 100%PLM White/Yellow None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551803844-0020A8A-2

Room 78/Paint- Concrete block wall

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/17/2018 0% 100%PLM White/Yellow None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551803844-0020B8A-3

Room 78/Paint- Concrete block wall

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/17/2018 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551803844-00218B

Room 65/Paint- Concrete block wall

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/13/2018 0% 99% 1% ChrysotilePLM Gray/Tan/White All layers of this sample included in the

result.

Client Sample ID:

Sample Description:

Lab Sample ID: 551803844-00228C

Room 65/Paint- Concrete block wall

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/13/2018PLM Positive Stop (Not Analyzed)

Test Report:EPAMultiTests-7.32.2.D Printed: 4/17/2018 03:53PM Page 4 of 5

Page 36: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551803844

702170-148

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Analyst(s):

PLM Grav. Reduction (2)Caroline Allen

PLM (2)Ewa Krupinska

PLM (16)Hilary Belleville

TEM Grav. Reduction (2)Natalie D'Amico

PLM (5)Simon Parent

Matthew Davis or other approved signatory

or Other Approved Signatory

Reviewed and approved by:

None Detected = <0.1%. EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported above and may

not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical

method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless

otherwise noted. This report must not be used to claim product endorsement by NVLAP of any agency of the U.S. Government.

Samples analyzed by EMSL Canada Inc. Mississauga, ON NVLAP Lab Code 200877-0Report amended: 04/17/201815:53:40 Replaces amended report from: 04/17/201814:50:12 Reason Code: Client-Additional Analysis

Test Report:EPAMultiTests-7.32.2.D Printed: 4/17/2018 03:53PM Page 5 of 5

Page 37: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L9T 5N4

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551703938

N/A

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Attn:

Proj: Brookdale PS /702170-122

Phone: (905) 882-5984

Fax: (905) 882-8962

Collected:

Received: 4/13/2017

Analyzed: 4/18/2017

Sean Parliament

ARCADIS Canada Inc.

121 Granton Drive

Unit 12

Richmond Hill, ON L4B 3N4

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551703938-00011A

Room 1/Concrete Block Filler Paint

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/18/2017 0% 100%PLM White Result includes a small amount of

inseparable attached materialNone Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551703938-00021B

Room 1/Concrete Block Filler Paint

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/18/2017 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551703938-00031C

Room 1/Concrete Block Filler Paint

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/18/2017 0% 100%PLM White None Detected

Analyst(s):

PLM (2)Natalie D'Amico

PLM (1)Shorthri Kalikutty

Matthew Davis

or Other Approved Signatory

Reviewed and approved by:

None Detected = <0.1%. EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported above and may

not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical

method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless

otherwise noted. This report must not be used to claim product endorsement by NVLAP of any agency of the U.S. Government.

Samples analyzed by EMSL Canada Inc. Mississauga, ON NVLAP Lab Code 200877-0Report amended: 04/19/201714:21:48 Replaces initial report from: 04/18/201715:56:32 Reason Code: Client-Change to Project

Test Report:EPAMultiTests-7.32.2.D Printed: 4/19/2017 02:21PM Page 1 of 1

Page 38: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L9T 5N4

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551603721

702170-057

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Attn:

Proj: 702170-057 (BROOKDALE))

Phone: (905) 882-5984

Fax: (905) 882-8962

Collected:

Received: 4/04/2016

Analyzed: 4/08/2016

Jean Daigle

ARCADIS Canada Inc.

121 Granton Drive

Unit 12

Richmond Hill, ON L4B 3N4

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551603721-00011-A

RM.74/BROWN ADHESIVE- 12" X 12" CT UNIFORM HOLES

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/07/2016 0.0% 100%PLM Grav. Reduction None DetectedBrown

4/08/2016 0.0% 100%TEM Grav. Reduction None DetectedBrown

Client Sample ID:

Sample Description:

Lab Sample ID: 551603721-00021-B

RM.72/BROWN ADHESIVE- 12" X 12" CT UNIFORM HOLES

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/07/2016 0% 100%PLM Brown None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551603721-00031-C

RM.69/BROWN ADHESIVE- 12" X 12" CT UNIFORM HOLES

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/07/2016 0% 100%PLM Brown None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551603721-00042-A

RM.68/CONCRETE BLOCK MORTAR

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/07/2016 0.0% 100%PLM Grav. Reduction None DetectedGray

4/08/2016 0.0% 100%TEM Grav. Reduction None DetectedGray

Client Sample ID:

Sample Description:

Lab Sample ID: 551603721-00052-B

RM.77/CONCRETE BLOCK MORTAR

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/07/2016 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551603721-00062-C

RM.69/CONCRETE BLOCK MORTAR

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/07/2016 0% 100%PLM Gray None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 4/08/2016 10:54AM Page 1 of 2

Page 39: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L9T 5N4

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551603721

702170-057

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551603721-00073-A

RM.27/BRICK MORTAR

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/07/2016 0.0% 100%PLM Grav. Reduction None DetectedGray

4/08/2016 0.0% 100%TEM Grav. Reduction None DetectedGray

Client Sample ID:

Sample Description:

Lab Sample ID: 551603721-00083-B

RM.27/BRICK MORTAR

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/07/2016 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551603721-00093-C

RM.27/BRICK MORTAR

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/07/2016 0% 100%PLM Gray None Detected

Analyst(s):

PLM Grav. Reduction (3)

TEM Grav. Reduction (3)

Arabee Sathiaseelan

PLM (6)Jon Delos Santos

Matthew Davis

or Other Approved Signatory

Reviewed and approved by:

None Detected = <0.5%. EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported above and may

not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical

method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless

otherwise noted. This report must not be used to claim product endorsement by NVLAP of any agency of the U.S. Government.

Samples analyzed by EMSL Canada Inc. Mississauga, ON NVLAP Lab Code 200877-0Initial report from: 04/08/201610:54:37

Test Report:EPAMultiTests-7.32.2.D Printed: 4/08/2016 10:54AM Page 2 of 2

Page 40: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and
Page 41: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and
Page 42: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

EMSL Canada Inc.

10 Falconer Drive, Unit #3 Mississauga, ON L5N 3L8

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.emsl.com / [email protected]

55DCSL97551205606

701713-000

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Attn:

Proj: BROOKDALE P.S

Phone: (905) 882-5984

Fax: (905) 882-8962

Collected:

Received: 11/23/2012

Analyzed: 1/08/2013

Ryan Farnsworth

Decommissioning Consulting Services Ltd.

121 Granton Drive

Unit 11

Richmond Hill, ON L4B 3N4

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-00011-A

ROOM: 49/12"X12" VINYL FLOOR TILE, BEIGE WITH ORANGE BROWN DIRECTIONAL

STREAKS

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 0.0% 100%PLM Grav. Reduction None DetectedTan /Various /Beige

11/30/2012 0.0% 100%TEM Grav. Reduction None DetectedTan /Various /Beige

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-00021-B

ROOM: 47/12"X12" VINYL FLOOR TILE, BEIGE WITH ORANGE BROWN DIRECTIONAL

STREAKS

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 0% 98% 2% ChrysotilePLM Gray

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-00031-C

ROOM: 39/12"X12" VINYL FLOOR TILE, BEIGE WITH ORANGE BROWN DIRECTIONAL

STREAKS

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012PLM Stop Positive (Not Analyzed)

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-00042-A

ROOM: 49/MASTIC: BLACK ON VINYL FLOOR TILE

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 0.0% 1.2%98.8% ChrysotilePLM Grav. Reduction Various /Black

11/29/2012TEM Grav. Reduction Positive Stop (Not Analyzed)

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-00052-B

ROOM: 49/MASTIC: BLACK ON VINYL FLOOR TILE

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012PLM Stop Positive (Not Analyzed)

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-00062-C

ROOM: 49/MASTIC: BLACK ON VINYL FLOOR TILE

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012PLM Stop Positive (Not Analyzed)

Test Report:EPAMultiTests-7.26.0 Printed: 1/08/2013 10:44AM Page 1 of 13

Page 43: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

EMSL Canada Inc.

10 Falconer Drive, Unit #3 Mississauga, ON L5N 3L8

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.emsl.com / [email protected]

55DCSL97551205606

701713-000

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-00073-A

ROOM: 49/VINYL BASEBOARD BROWN

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 0.0% 100%PLM Grav. Reduction None DetectedBrown

11/30/2012 0.0% 100%TEM Grav. Reduction None DetectedBrown

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-00083-B

ROOM: 51/VINYL BASEBOARD BROWN

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 0% 100%PLM Tan None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-00093-C

ROOM: 53/VINYL BASEBOARD BLACK

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-00104-A

ROOM: 49/MASTIC, MIX OF DARK AND LIGHT BROWN OFF BLACK VINYL BASE

BOARD

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 0.0% 100%PLM Grav. Reduction None DetectedBrown

11/30/2012 0.0% 100%TEM Grav. Reduction None DetectedBrown

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-00114-B

ROOM: 51/MASTIC, MIX OF DARK AND LIGHT BROWN OFF BLACK VINYL BASE

BOARD

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 0% 100%PLM Tan None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-00124-C

ROOM: 53/MASTIC, MIX OF DARK AND LIGHT BROWN OFF BLACK VINYL BASE

BOARD

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 0% 100%PLM Tan None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-00135-A

ROOM: 53/CEMENTITIOUS FLOOR TILE, TERRACOTTA COLOUR

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 0.0% 100%PLM Grav. Reduction None DetectedBrown /Red

11/30/2012 0.0% 100%TEM Grav. Reduction None DetectedBrown /Red

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-00145-B

ROOM: 52/CEMENTITIOUS FLOOR TILE, TERRACOTTA COLOUR

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 30% 70%PLM Brown None Detected

Test Report:EPAMultiTests-7.26.0 Printed: 1/08/2013 10:44AM Page 2 of 13

Page 44: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

EMSL Canada Inc.

10 Falconer Drive, Unit #3 Mississauga, ON L5N 3L8

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.emsl.com / [email protected]

55DCSL97551205606

701713-000

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-00155-C

ROOM: 53/CEMENTITIOUS FLOOR TILE, TERRACOTTA COLOUR

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 40% 60%PLM Brown None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-00166-A

ROOM: 53/CEMENT BASE FROM CEMENTITIOUS FLOOR TILE

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 0.0% 100%PLM Grav. Reduction None DetectedGray /Red

11/30/2012 0.0% 100%TEM Grav. Reduction None DetectedGray /Red

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-00176-B

ROOM: 53/CEMENT BASE FROM CEMENTITIOUS FLOOR TILE

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-00186-C

ROOM: 53/CEMENT BASE FROM CEMENTITIOUS FLOOR TILE

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-00197-A

ROOM: 48/12"X12" VINYL FLOOR TILE, LIGHT AND DARK BROWN WITH LIGHT AND

DARK FLECKS

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 0.0% 100%PLM Grav. Reduction None DetectedBrown /Tan

11/30/2012 0.0% 100%TEM Grav. Reduction None DetectedBrown /Tan

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-00207-B

ROOM: 29/12"X12" VINYL FLOOR TILE, LIGHT AND DARK BROWN WITH LIGHT AND

DARK FLECKS

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-00217-C

ROOM: 25/12"X12" VINYL FLOOR TILE, LIGHT AND DARK BROWN WITH LIGHT AND

DARK FLECKS

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-00228-A

ROOM: 32/12"X12" VINYL FLOOR TILE, WHITE WITH BLUE FLECKS

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 0.0% 100%PLM Grav. Reduction None DetectedWhite /Various /Blue

11/30/2012 0.0% 100%TEM Grav. Reduction None DetectedWhite /Various /Blue

Test Report:EPAMultiTests-7.26.0 Printed: 1/08/2013 10:44AM Page 3 of 13

Page 45: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

EMSL Canada Inc.

10 Falconer Drive, Unit #3 Mississauga, ON L5N 3L8

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.emsl.com / [email protected]

55DCSL97551205606

701713-000

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-00238-B

ROOM: 35/12"X12" VINYL FLOOR TILE, WHITE WITH BLUE FLECKS

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-00248-C

ROOM: 34/12"X12" VINYL FLOOR TILE, WHITE WITH BLUE FLECKS

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-00259-A

ROOM: 36/9"X9" VINYL FLOOR TILE, RED WITH BLACK STREAKS

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 0.0% 2.8%97.2% ChrysotilePLM Grav. Reduction Red

11/29/2012TEM Grav. Reduction Positive Stop (Not Analyzed)

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-00269-B

ROOM: 36/9"X9" VINYL FLOOR TILE, RED WITH BLACK STREAKS

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012PLM Stop Positive (Not Analyzed)

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-00279-C

ROOM: 36/9"X9" VINYL FLOOR TILE, RED WITH BLACK STREAKS

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012PLM Stop Positive (Not Analyzed)

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-002810-A

ROOM: 29/9"X9" VINYL FLOOR TILE, GREEN/ BROWN/ WHITE WITH CREAM OR

BLACK STREAKS

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 0.0% 1.7%98.3% ChrysotilePLM Grav. Reduction Various /Green

11/29/2012TEM Grav. Reduction Positive Stop (Not Analyzed)

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-002910-B

ROOM: 73/9"X9" VINYL FLOOR TILE, GREEN/ BROWN/ WHITE WITH CREAM OR

BLACK STREAKS

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012PLM Stop Positive (Not Analyzed)

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-003010-C

ROOM: 68/9"X9" VINYL FLOOR TILE, GREEN/ BROWN/ WHITE WITH CREAM OR

BLACK STREAKS

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012PLM Stop Positive (Not Analyzed)

Test Report:EPAMultiTests-7.26.0 Printed: 1/08/2013 10:44AM Page 4 of 13

Page 46: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

EMSL Canada Inc.

10 Falconer Drive, Unit #3 Mississauga, ON L5N 3L8

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.emsl.com / [email protected]

55DCSL97551205606

701713-000

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-003111-A

ROOM: 21/9"X9" VINYL FLOOR TILE, GREY/ WHITE WITH WHITE OR MULTI COLOUR

STREAKS

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 0.0% 2.1%97.9% ChrysotilePLM Grav. Reduction Gray /White /Various

11/29/2012TEM Grav. Reduction Positive Stop (Not Analyzed)

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-003211-B

ROOM: 74/9"X9" VINYL FLOOR TILE, GREY/ WHITE WITH WHITE OR MULTI COLOUR

STREAKS

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012PLM Stop Positive (Not Analyzed)

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-003311-C

ROOM: 71/9"X9" VINYL FLOOR TILE, GREY/ WHITE WITH WHITE OR MULTI COLOUR

STREAKS

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012PLM Stop Positive (Not Analyzed)

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-003412-A

ROOM: 49/ANTI-SWEAT BLACK PAPER ON 4" COLD WATER LINE

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 0.0% <0.25%100% ChrysotilePLM Grav. Reduction Brown /Various /Black

11/30/2012 0.0% 100% ChrysotileTEM Grav. Reduction Brown /Various /Black <0.25%

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-003512-B

ROOM: 51/ANTI-SWEAT BLACK PAPER ON 4" COLD WATER LINE

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 70% 30%PLM Brown/Black None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-003612-C

ROOM: 55/ANTI-SWEAT BLACK PAPER ON 4" COLD WATER LINE

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 0% 100% <0.25% Chrysotile400 PLM Pt Ct Black

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-003713-A

ROOM: 49/HORSE HAIR ON COLD WATER PIPE FITTING

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 0% 98% 2% ChrysotilePLM Brown

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-003813-B

ROOM: 51/HORSE HAIR ON COLD WATER PIPE STRAIGHT

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

1/08/2013 95% 4% 1% ChrysotilePLM Brown/Gray

Test Report:EPAMultiTests-7.26.0 Printed: 1/08/2013 10:44AM Page 5 of 13

Page 47: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

EMSL Canada Inc.

10 Falconer Drive, Unit #3 Mississauga, ON L5N 3L8

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.emsl.com / [email protected]

55DCSL97551205606

701713-000

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-003913-C

ROOM: 23/HORSE HAIR ON COLD WATER PIPE STRAIGHT

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

1/08/2013 99% 1%PLM Brown None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-004014-A

ROOM: 49/CAULKING, GREY, INTERIOR WINDOW FRAMES

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 0.0% 100%PLM Grav. Reduction None DetectedGray

11/30/2012 0.0% 100%TEM Grav. Reduction None DetectedGray

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-004114-B

ROOM: 49/CAULKING, GREY, INTERIOR WINDOW FRAMES

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-004214-C

ROOM: 53/CAULKING, GREY, INTERIOR WINDOW FRAMES

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-004315-A

ROOM: 52/CAULKING, GREY, INTERIOR DOOR FRAMES

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 0.0% 100%PLM Grav. Reduction None DetectedGray

11/30/2012 0.0% 100%TEM Grav. Reduction None DetectedGray

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-004415-B

ROOM: 52/CAULKING, GREY, INTERIOR DOOR FRAMES

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 0% 100%PLM Gray/Various None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-004515-C

ROOM: 55/CAULKING, GREY, INTERIOR DOOR FRAMES

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-004616-A

ROOM: 50/CEILING TILE MASTIC, DARK BROWN

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 0.0% 100%PLM Grav. Reduction None DetectedBrown

11/30/2012 0.0% 100%TEM Grav. Reduction None DetectedBrown

Test Report:EPAMultiTests-7.26.0 Printed: 1/08/2013 10:44AM Page 6 of 13

Page 48: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

EMSL Canada Inc.

10 Falconer Drive, Unit #3 Mississauga, ON L5N 3L8

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.emsl.com / [email protected]

55DCSL97551205606

701713-000

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-004716-B

ROOM: 53/CEILING TILE MASTIC, DARK BROWN

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 0% 100%PLM Brown None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-004816-C

ROOM: 53/CEILING TILE MASTIC, DARK BROWN

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 5% 95%PLM Brown/Various None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-004917-A

ROOM: 49/CAULKING, GREY, EXTERIOR WINDOW FRAME

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 0.0% 100%PLM Grav. Reduction None DetectedGray /Various

11/30/2012 0.0% 100%TEM Grav. Reduction None DetectedGray /Various

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-005017-B

ROOM: 53/CAULKING, GREY, EXTERIOR WINDOW FRAME

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-005117-C

ROOM: 56/CAULKING, GREY, EXTERIOR WINDOW FRAME

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 0% 100%PLM Gray/Various None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-005218-A

EXTERIOR/CAULKING ON EXTERIOR DUCT ON SAW DUST COLLECTOR

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 0.0% 100%PLM Grav. Reduction None DetectedGray

11/30/2012 0.0% 100%TEM Grav. Reduction None DetectedGray

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-005318-B

EXTERIOR/CAULKING ON EXTERIOR DUCT ON SAW DUST COLLECTOR

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-005418-C

EXTERIOR/CAULKING ON EXTERIOR DUCT ON SAW DUST COLLECTOR

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 0% 100%PLM White None Detected

Test Report:EPAMultiTests-7.26.0 Printed: 1/08/2013 10:44AM Page 7 of 13

Page 49: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

EMSL Canada Inc.

10 Falconer Drive, Unit #3 Mississauga, ON L5N 3L8

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.emsl.com / [email protected]

55DCSL97551205606

701713-000

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-005519-A

ROOM: 45/DRYWALL JOINT COMPOUND FROM WALL (1958)

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 0.0% 100%PLM Grav. Reduction None DetectedWhite

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-005619-B

ROOM: 44/DRYWALL JOINT COMPOUND FROM WALL (1958)

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 0.0% 100%PLM Grav. Reduction None DetectedWhite

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-005719-C

ROOM: 40/DRYWALL JOINT COMPOUND FROM WALL (1958)

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 0.0% 100%PLM Grav. Reduction None DetectedWhite

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-005819-D

ROOM: 80/DRYWALL JOINT COMPOUND FROM WALL (1958)

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 0.0% 100%PLM Grav. Reduction None DetectedGray /Tan

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-005919-E

ROOM: 79/DRYWALL JOINT COMPOUND FROM WALL (1958)

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 0.0% 100%PLM Grav. Reduction None DetectedGray /Tan

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-006020-A

ROOM: 9/DRYWALL JOINT COMPOUND FROM CEILING PATCH (1983)

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 0.0% 100%PLM Grav. Reduction None DetectedWhite

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-006120-B

ROOM: 9/DRYWALL JOINT COMPOUND FROM CEILING PATCH (1983)

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 0.0% 100%PLM Grav. Reduction None DetectedWhite

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-006220-C

ROOM: 2/DRYWALL JOINT COMPOUND FROM CEILING PATCH (1983)

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 0.0% 100%PLM Grav. Reduction None DetectedGray /Tan /White

Test Report:EPAMultiTests-7.26.0 Printed: 1/08/2013 10:44AM Page 8 of 13

Page 50: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

EMSL Canada Inc.

10 Falconer Drive, Unit #3 Mississauga, ON L5N 3L8

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.emsl.com / [email protected]

55DCSL97551205606

701713-000

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-006321-A

ROOM: 23/PLASTER, WHITE TOP COAT FROM CEILING

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 0.0% 100%PLM Grav. Reduction None DetectedWhite

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-006421-B

ROOM: 23/PLASTER, WHITE TOP COAT FROM CEILING

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 0.0% 100%PLM Grav. Reduction None DetectedWhite

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-006521-C

ROOM: 77/PLASTER, WHITE TOP COAT FROM CEILING

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 0.0% 100%PLM Grav. Reduction None DetectedWhite

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-006622-A

ROOM: 23/PLASTER, GREY BOTTOM COAT FROM CEILING (1958)

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 0.0% 100%PLM Grav. Reduction None DetectedGray /Various

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-006722-B

ROOM: 23/PLASTER, GREY BOTTOM COAT FROM CEILING (1958)

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 0.0% 100%PLM Grav. Reduction None DetectedGray /Various

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-006822-C

ROOM: 77/PLASTER, GREY BOTTOM COAT FROM CEILING (1958)

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 0.0% 100%PLM Grav. Reduction None DetectedGray /Various

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-006923-A

ROOM: 7/PLASTER, GREY COAT FROM CEILING (1983)

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 0.0% 100%PLM Grav. Reduction None DetectedGray

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-007023-B

ROOM: 6/PLASTER, GREY COAT FROM CEILING (1983)

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 0.0% 100%PLM Grav. Reduction None DetectedGray

Test Report:EPAMultiTests-7.26.0 Printed: 1/08/2013 10:44AM Page 9 of 13

Page 51: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

EMSL Canada Inc.

10 Falconer Drive, Unit #3 Mississauga, ON L5N 3L8

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.emsl.com / [email protected]

55DCSL97551205606

701713-000

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-007123-C

ROOM: 8/PLASTER, GREY COAT FROM CEILING (1983)

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 0.0% 100%PLM Grav. Reduction None DetectedGray

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-007224-A

ROOM: 49/2'X4' CEILING TILE, FISSURES ON 2' WITH PINHOLES

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 80% 20%PLM Gray/White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-007324-B

ROOM: 58/2'X4' CEILING TILE, FISSURES ON 2' WITH PINHOLES

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 80% 20%PLM Gray/White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-007424-C

ROOM: 59/2'X4' CEILING TILE, FISSURES ON 2' WITH PINHOLES

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 75% 25%PLM Gray/White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-007525-A

ROOM: 50/12"X12" CEILING TILE, LARGE AND SMALL HOLES WITH WAVY SURFACE

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 85% 15%PLM Gray/White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-007625-B

ROOM: 54/12"X12" CEILING TILE, LARGE AND SMALL HOLES WITH WAVY SURFACE

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 85% 15%PLM Gray/White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-007725-C

ROOM: 35/12"X12" CEILING TILE, LARGE AND SMALL HOLES WITH WAVY SURFACE

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 80% 20%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-007826-A

ROOM: 57/12"X12" CEILING TILE, SMOOTH FACE

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 85% 15%PLM White None Detected

Test Report:EPAMultiTests-7.26.0 Printed: 1/08/2013 10:44AM Page 10 of 13

Page 52: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

EMSL Canada Inc.

10 Falconer Drive, Unit #3 Mississauga, ON L5N 3L8

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.emsl.com / [email protected]

55DCSL97551205606

701713-000

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-007926-B

ROOM: 53/12"X12" CEILING TILE, SMOOTH FACE

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 85% 15%PLM Gray/White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-008026-C

ROOM: 56/12"X12" CEILING TILE, SMOOTH FACE

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 85% 15%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-008127-A

ROOM: 56/12"X12" CEILING TILE, UNIFORMED HOLES IN STRAIGHT LINES

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 85% 15%PLM Gray/White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-008227-B

ROOM: 53/12"X12" CEILING TILE, UNIFORMED HOLES IN STRAIGHT LINES

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 85% 15%PLM Gray/White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-008327-C

ROOM: 71/12"X12" CEILING TILE, UNIFORMED HOLES IN STRAIGHT LINES

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 0% 100%PLM Gray/White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-008428-A

ROOM: 56/12"X12" CEILING TILE, LARGE AND SMALL HOLES WITH SMOOTH

SURFACE

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 85% 15%PLM Gray/White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-008528-B

ROOM: 56/12"X12" CEILING TILE, LARGE AND SMALL HOLES WITH SMOOTH

SURFACE

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 85% 15%PLM Gray/White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-008628-C

ROOM: 56/12"X12" CEILING TILE, LARGE AND SMALL HOLES WITH SMOOTH

SURFACE

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 70% 30%PLM Gray None Detected

Test Report:EPAMultiTests-7.26.0 Printed: 1/08/2013 10:44AM Page 11 of 13

Page 53: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

EMSL Canada Inc.

10 Falconer Drive, Unit #3 Mississauga, ON L5N 3L8

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.emsl.com / [email protected]

55DCSL97551205606

701713-000

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-008729-A

ROOM: 60/2'X4' CEILING TILE, "L" FISSURE

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 80% 20%PLM Tan/White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-008829-B

ROOM: 62/2'X4' CEILING TILE, "L" FISSURE

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 85% 15%PLM Gray/White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-008929-C

ROOM: 64/2'X4' CEILING TILE, "L" FISSURE

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 70% 30%PLM Gray/White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-009030-A

ROOM: 42/2'X4' CEILING TILE, MEDIUM AND SMALL PINHOLES

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 80% 20%PLM Tan/White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-009130-B

ROOM: 37/2'X4' CEILING TILE, MEDIUM AND SMALL PINHOLES

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 80% 20%PLM Tan/White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-009230-C

ROOM: 31/2'X4' CEILING TILE, MEDIUM AND SMALL PINHOLES

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 60% 40%PLM Brown/Various None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-009331-A

ROOM: 25/12"X12" CEILING TILE, MEDIUM AND SMALL PINHOLES

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 80% 20%PLM Tan/White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-009431-B

ROOM: 25/12"X12" CEILING TILE, MEDIUM AND SMALL PINHOLES

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 80% 20%PLM Gray/White None Detected

Test Report:EPAMultiTests-7.26.0 Printed: 1/08/2013 10:44AM Page 12 of 13

Page 54: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

EMSL Canada Inc.

10 Falconer Drive, Unit #3 Mississauga, ON L5N 3L8

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.emsl.com / [email protected]

55DCSL97551205606

701713-000

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-009531-C

ROOM: 15/12"X12" CEILING TILE, MEDIUM AND SMALL PINHOLES

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/30/2012 70% 30%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551205606-009632

ROOM: 16/2'X4' CEILING TILE, DENTED FISSURE WITH PINHOLES DATE CODE:

09/10/08

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

11/29/2012 80% 20%PLM Tan/White None Detected

Analyst(s)

Kevin Pang

or other Approved Signatory

Alice Feng PLM (18)

PLM Grav. Reduction (29)

Kevin Pang TEM Grav. Reduction (13)

Merriam Haffar PLM (34)

400 PLM Pt Ct (1)

PLM Grav. Reduction (5)

Any questions please contact Kevin Pang.

None Detected = <0.5%. EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by

EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good

condition unless otherwise noted. This report must not be used to claim product endorsement by NVLAP of any agency of the U.S. Government.

Samples analyzed by EMSL Canada Inc. Mississauga, ON NVLAP Lab Code 200877-0

Report amended: 01/08/201310:44:24 Replaces initial report from: 11/30/201215:35:15 Reason Code: Client-Additional Analysis

Test Report:EPAMultiTests-7.26.0 Printed: 1/08/2013 10:44AM Page 13 of 13

Page 55: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551901286

702170-188

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Attn:

Proj: Brookdale P.S. / 702170-188

Phone: (905) 882-5984

Fax: (905) 882-8962

Collected:

Received: 2/04/2019

Analyzed: 2/11/2019

Ada Nguyen

ARCADIS Canada Inc.

121 Granton Drive

Unit 12

Richmond Hill, ON L4B 3N4

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551901286-00011A

Room 21/Black Mastic below 9" vinyl floor tiles

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

2/11/2019 0.0% 97.0% 3% ChrysotilePLM Black

Client Sample ID:

Sample Description:

Lab Sample ID: 551901286-00021B

Room 71/Black Mastic below 9" vinyl floor tiles

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

2/11/2019PLM Positive Stop (Not Analyzed)

Client Sample ID:

Sample Description:

Lab Sample ID: 551901286-00031C

Room 72/Black Mastic below 9" vinyl floor tiles

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

2/11/2019PLM Positive Stop (Not Analyzed)

Client Sample ID:

Sample Description:

Lab Sample ID: 551901286-00042A

Room 21/Brown adhesive on 12x12 ceiling tiles (smooth surface & uniform holes)

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

2/11/2019 0.0% 100.0%PLM Brown None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551901286-00052B

Room 48/Brown adhesive on 12x12 ceiling tiles (smooth surface & uniform holes)

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

2/11/2019 0.0% 100.0%PLM Brown None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551901286-00062C

Room 53/Brown adhesive on 12x12 ceiling tiles (smooth surface & uniform holes)

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

2/11/2019 0.0% 100.0%PLM Brown None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551901286-00073A

Room 21/Black vinyl baseboard

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

2/11/2019 0.0% 100%PLM Grav. Reduction None DetectedBlack

2/11/2019 0.0% 100.0%TEM Grav. Reduction None DetectedBlack

Test Report:EPAMultiTests-7.32.2.D Printed: 2/11/2019 03:58PM Page 1 of 3

Page 56: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551901286

702170-188

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551901286-00083B

Room 71/Black vinyl baseboard

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

2/11/2019 0.0% 100.0%PLM Black None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551901286-00093C

Room 72/Black vinyl baseboard

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

2/11/2019 0.0% 100.0%PLM Black None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551901286-00104A

Room 21/Brown mastic on black vinyl baseboard

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

2/11/2019 0.0% 100.0%PLM Brown None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551901286-00114B

Room 72/Brown mastic on black vinyl baseboard

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

2/11/2019 0.0% 100.0%PLM Brown None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551901286-00124C

Room 71/Brown mastic on black vinyl baseboard

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

2/11/2019 0.0% 100.0%PLM Brown None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551901286-00135A

Room 22/Brown adhesive on 12x12 ceiling tiles (small & large holes)

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

2/11/2019 0.0% 100.0%PLM Brown None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551901286-00145B

Room 24/Brown adhesive on 12x12 ceiling tiles (small & large holes)

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

2/11/2019 0.0% 100.0%PLM Brown None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551901286-00155C

Room 32/Brown adhesive on 12x12 ceiling tiles (small & large holes)

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

2/11/2019 0.0% 100.0%PLM Brown None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 2/11/2019 03:58PM Page 2 of 3

Page 57: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551901286

702170-188

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Analyst(s):

TEM Grav. Reduction (1)Anne Balayboa

PLM (10)Khaledeh Tahmasbipoor

PLM (2)

PLM Grav. Reduction (1)

Michelle Lung

Matthew Davis or other approved signatory

or Other Approved Signatory

Reviewed and approved by:

None Detected = <0.1%. EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported above and may

not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical

method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless

otherwise noted. This report must not be used to claim product endorsement by NVLAP of any agency of the U.S. Government.

Samples analyzed by EMSL Canada Inc. Mississauga, ON NVLAP Lab Code 200877-0Initial report from: 02/11/201915:58:00

Test Report:EPAMultiTests-7.32.2.D Printed: 2/11/2019 03:58PM Page 3 of 3

Page 58: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

APPENDIX C Sample List of Suspect Asbestos-Containing Building Materials from A Guide to the Regulation Respecting Asbestos on Construction Projects and in Buildings and Repair Operations

Page 59: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

1

APPENDIX C

SAMPLE LIST OF SUSPECT ASBESTOS-CONTAINING BUILDING MATERIALS There are an estimated 3,000 products that contain asbestos. In Ontario, asbestos was widely used in sprayed-on material and in pipe and boiler insulation until 1973(1). The use of many other asbestos-containing materials continued until the mid-1980s. Asbestos is still used in the manufacture of a limited number of products, including some floor tiles, cement products, friction materials and textiles. The following list was adapted from the United States Environmental Protection Agency’s (EPA) Sample List of Suspect Asbestos Containing Materials(2). It is not an all inclusive list but is intended as a general guide to show which types of building materials may contain asbestos.

Possible Asbestos-Containing Materials in Buildings

• Acoustical Plaster • Elevator Equipment Panels

• Adhesives • Fire Doors

• Asphalt Floor Tile • Fireproofing Materials

• Base Flashing • Flooring Backing

• Blown-in (Loose Fill) Insulation • Heating and Electrical Ducts

• Boiler Insulation • High Temperature Gaskets

• Breaching Insulation • HVAC Duct Insulation

• Caulking/Putties • Joint Compounds

• Ceiling Tiles and Lay-in Panels • Pipe Insulation (corrugated air-cell,

• Cement Pipes • block, etc.)

• Cement Siding • Roofing Felt

• Cement Wallboard • Roofing Shingles

• Construction Mastics (floor tile, • Spackling Compounds

• carpet, ceiling tile, etc.) • Sprayed-on Insulation

• Cooling Towers • Taping Compounds (thermal)

• Decorative Plaster • Textured Paper Products

• Ductwork Flexible Fabric Connections • Vinyl Floor Tile

• Electrical Cloth • Vinyl Sheet Flooring

• Electrical Wiring Insulation • Vinyl Wall Coverings

• Elevator Brake Shoes • Wallboard

(1) J.S. Dupre, J.F. Mustard & R.J. Uffin, Report of the Royal Commission on Matters of Health and Safety Arising from the Use

of Asbestos in Ontario, Ontario Ministry of the Attorney General, Toronto, Ontario, 1984, page 12. (2) U.S. Environmental Protection Agency, http://www.epa.gov/Region06/6pd/asbestos/asbmatl.htm.

Page 60: SURVEY OF ASBESTOS- CONTAINING MATERIALS...asbestos content. Determination of the locations of asbestos-containing materials were made based on results of bulk sample analysis, and

Arcadis Canada Inc.

121 Granton Drive, Suite 12, Richmond Hill, Ontario L4B 3N4

Tel 905 882 5984

Fax 905 882 8962

www.arcadis.com