HALTON DISTRICT SCHOOL BOARD
SURVEY OF ASBESTOS-CONTAINING MATERIALS
PINE GROVE PUBLIC SCHOOL
529 FOURTH LINE, OAKVILLE, ONTARIO
Updated February 10, 2020
30038950
SURVEY OF ASBESTOS-CONTAINING MATERIALS
PINE GROVE PUBLIC SCHOOL
arcadis.com i
SURVEY OF ASBESTOS-CONTAINING MATERIALS
PINE GROVE PUBLIC SCHOOL
529 Fourth Line, Oakville, Ontario
Prepared for:
Halton District School Board
J.W. Singleton Education Centre
2050 Guelph Line
Burlington, ON L7P 5A8
Attention: Terry DeMedeiros
Regional Supervisor, Facilities Maintenance
Prepared by:
Arcadis Canada Inc.
121 Granton Drive, Suite 12
Richmond Hill, Ontario L4B 3N4
Tel 905 764 9380
Our Ref.:
30038950
Date:
February 10, 2020
This document is intended only for the use of
the individual or entity for which it was
prepared and may contain information that is
privileged, confidential and exempt from
disclosure under applicable law. Any
dissemination, distribution or copying of this
document is strictly prohibited.
Shubham Shringi, B.Eng., E.I.T.
Environmental Specialist
Ada Nguyen, B.Sc., CIH
Project Manager, Industrial Hygienist
SURVEY OF ASBESTOS-CONTAINING MATERIALS
PINE GROVE PUBLIC SCHOOL
arcadis.com ii
CONTENTS
1 INTRODUCTION ................................................................................................................................ 1-1
2 METHODOLOGY ............................................................................................................................... 2-1
2.1 Survey ........................................................................................................................................ 2-1
2.2 Assessment ................................................................................................................................ 2-1
3 SURVEY RESULTS ........................................................................................................................... 3-1
4 DISCUSSION ..................................................................................................................................... 4-1
5 USE AND LIMITATIONS OF THIS REPORT .................................................................................... 5-1
TABLES
Table 1.1 Bulk Material Samples (from O.Reg. 278/05) .................................................................. 1-2
Table 3.1 Summary of Laboratory Analyses of Bulk Samples ......................................................... 3-2
Table 3.2 Summary of Asbestos-Containing Materials ................................................................... 3-8
APPENDICES
Appendix A Floor Plans
Appendix B Laboratory Reports
Appendix C Sample List of Suspect Asbestos-Containing Building Materials from A Guide to
the Regulation Respecting Asbestos on Construction Projects and in Buildings
and Repair Operations
SURVEY OF ASBESTOS-CONTAINING MATERIALS
PINE GROVE PUBLIC SCHOOL
arcadis.com 1-1
1 INTRODUCTION
Arcadis Canada Inc. (Arcadis) was retained by the Halton District School Board to provide an updated
survey of the locations of asbestos-containing materials at Pine Grove Public School located at 529 Fourth
Line in Oakville, Ontario following asbestos remediation associated with the renovation project in July 2019.
Asbestos has been widely used in buildings, both in friable applications (materials which can be easily
crumbled such as pipe and tank insulation, sprayed-on fireproofing and acoustic and texture coat
applications) and in non-friable materials such as floor tile, fire-rated ceiling tile, gaskets, cement board,
cement pipe, drywall joint compound and so on. Plaster applications (walls, ceilings, bulkheads, etc.) may
also contain asbestos. The use of asbestos in friable applications was curtailed in Ontario around the
mid-1970s. Most buildings constructed prior to about the mid-1970s contain some form of friable
asbestos-containing material. The use of asbestos in certain non-friable products continued beyond the
1970s. A sample list of suspect asbestos containing building materials is provided in Appendix C.
Control of exposure to asbestos is governed in Ontario by Regulation 278/05 - Designated Substance -
Asbestos on Construction Projects and in Buildings and Repair Operations. Disposal of asbestos waste
(friable and non-friable materials) is governed by Ontario Regulation 278/05 and by Ontario Regulation 347,
Waste Management - General.
The major requirements of O.Reg. 278/05 with respect to asbestos surveys and assessments are as
follows:
Survey Records:
• non-friable asbestos-containing materials (e.g., vinyl floor tiles, ceiling tiles, drywall joint
compound, plaster, etc.) are to be included in asbestos survey records effective
1 November 2007;
• asbestos survey records are to be updated:
(a) at least once in every 12-month period;
(b) whenever the owner becomes aware of new information; and
• asbestos-containing materials are to be inspected at reasonable intervals in order to
determine their condition.
Bulk Samples:
• the minimum number of bulk samples to be collected from an area of homogeneous
material is set out in Table 1 of the Regulation (Table 1 is reproduced below).
• if analysis establishes that a bulk material sample contains 0.5 per cent or more asbestos
by dry weight:
(a) it is not necessary to analyze other bulk material samples taken from the same
area of homogeneous material; and
(b) the entire area of homogeneous material from which the bulk materials sample
was taken is deemed to be asbestos-containing material.
SURVEY OF ASBESTOS-CONTAINING MATERIALS
PINE GROVE PUBLIC SCHOOL
arcadis.com 1-2
Table 1.1: Bulk Material Samples (from O.Reg. 278/05)
Item Type of Material Size of Area of
Homogeneous Material
Minimum Number of Bulk
Material Samples to be
Collected
1.
Surfacing material, including without limitation material that is applied to surfaces by spraying, by trowelling or otherwise, such as acoustical plaster on ceilings and fireproofing materials on structural members
Less than 90 square metres 3
90 or more square metres, but less than 450 square
metres 5
450 or more square metres 7
2. Thermal insulation, except as described in Item 3
Any size 3
3. Thermal insulation patch Less than 2 linear metres or
0.5 square metres 1
4. Other material Any size 3
In practice, application of the Table 1 requirements means that the specified minimum number of negative
(i.e., less than 0.5% asbestos) bulk sample analysis results will be required in order to classify a material
as non asbestos.
Section 10 of O.Reg. 278/05 – Owner’s Responsibility before requesting tender or arranging work – requires
that an owner shall have an investigation carried out in order to determine if materials, that are likely to be
handled, dealt with, disturbed or removed during the alteration of a building, are asbestos-containing and,
if so, whether the asbestos-containing material is friable or non-friable and to identify the type of asbestos
in the material. Section 10 also requires that the owner shall have a report prepared detailing the
investigation findings which is to be provided to any prospective constructor.
Corrective Actions
If asbestos containing fireproofing or acoustical or thermal insulation has fallen and is being disturbed so
that exposure to the material is likely to occur, O.Reg. 278/05 requires that the owner shall cause the fallen
material to be cleaned up and, if it is readily apparent that material will continue to fall because of the
deterioration, the owner shall repair, seal, remove or permanently enclose the material.
O.Reg. 278/05 classifies the asbestos work operations into three types (Type 1, 2 and 3) and specifies
procedures to be followed in conducting asbestos abatement work.
SURVEY OF ASBESTOS-CONTAINING MATERIALS
PINE GROVE PUBLIC SCHOOL
arcadis.com 2-1
2 METHODOLOGY
2.1 Survey
Site inspections were carried out by Arcadis staff in December 1999 to determine the locations of building
construction materials suspected of containing asbestos. All readily accessible areas, including spaces
above accessible suspended ceilings, were inspected throughout the facility. Site inspections were also
performed in select areas of the building in July 2013.
Additional site inspections were performed in select areas of the building in December 2019 as part of a
building renovation project. This report has been updated to include information from additional
investigations and remediation that took place in 2019.
Representative bulk samples of material were collected by Arcadis staff during the course of the site
inspection and were forwarded to EMSL Analytical Inc. and EMSL Canada Inc. (EMSL) for analysis of
asbestos content. Determination of the locations of asbestos-containing materials were made based on
results of bulk sample analysis, and on visual observations and physical characteristics of the applications
at each inspection location.
2.2 Assessment
During the survey, the condition of all friable materials is assessed. Assessment involves the evaluation of
a number of factors, including:
• asbestos content;
• physical damage;
• water damage;
• accessibility;
• adjacent activity, vibrations;
• air distribution system (air plenum); and
• friability.
Recommendations for appropriate corrective measures are based on findings of the assessment and
consist primarily of either repair or removal (and replacement) of the asbestos containing materials. No
recommended corrective actions were required at the time that this report was prepared.
SURVEY OF ASBESTOS-CONTAINING MATERIALS
PINE GROVE PUBLIC SCHOOL
arcadis.com 3-1
3 SURVEY RESULTS
Arcadis reviewed reports prepared by Arcadis for the Halton District School Board entitled Survey and
Assessment of Asbestos-Containing Materials, Pine Grove Public School, Oakville Ontario dated August
2013, Pre-Renovation Designated Substances and Hazardous Materials Survey, Pine Grove Public School,
529 Fourth Line, Oakville, Ontario, dated April 30, 2017, and Pre-Renovation Designated Substances and
Hazardous Materials Survey, Pine Grove Public School, 529 Fourth Line, Oakville, Ontario dated April 11,
2019. Information and/or bulk sample analysis results obtained from these reports were utilized by Arcadis
in the preparation of this report.
On the basis of the survey work carried out, we report that friable asbestos containing materials are present
in Pine Grove Public School in the following accessible applications:
• thermal insulation applied to pipe fittings below ceilings in Rooms 1A, 23A, 33, 33A and 46;
• thermal insulation applied to pipe fittings above ceilings in Room 42A and Corridors 49, 50, 51, 53,
54 and 55;
• thermal insulation applied to pipe straights in Corridors 53, 54 and 55;
• boiler breeching insulation in Room 33; and
• vermiculite roofing material in the southeast roof.
Asbestos-containing thermal insulation applied to pipe fittings is a grey-coloured cementitious material.
Asbestos-containing thermal insulation applied to pipe straights is “Air-Cell” or “Anti-sweat” insulation.
“Aircell” is a trade name for a grey-coloured corrugated paper-like type of pipe insulation, usually found on
heating and domestic hot water piping. “Anti-sweat” insulation is a layered paper-like material, typically
brown in colour that may contain intermittent layers of black tar-like paper and/or intermittent layers of a
white paper-like material, usually found on domestic cold-water lines and sanitary and rainwater piping.
Glass fibre insulation is readily visually distinguishable (typically yellow in colour) from asbestos containing
insulation materials and was, therefore, not tested for asbestos content.
All thermal insulation, with the exception of glass fibre material, should be assumed to contain asbestos
unless a bulk sample analysis indicates otherwise.
Visual inspections and laboratory analyses of representative bulk samples of materials confirm that
non-friable asbestos-containing materials are present in the following accessible applications:
• vinyl floor tiles (assumed asbestos) throughout the facility;
• cement pipe (assumed asbestos) in pipe chases in Rooms 28 and 30A; and
• cement board (assumed asbestos) on exterior fascia throughout the building.
A room-by-room summary of the locations and conditions of asbestos-containing materials identified is
presented in Table 3.2. The locations of accessible asbestos containing materials are identified on the floor
plans provided in Appendix A.
A summary of the results of laboratory analysis of bulk samples is presented in Table 3.1. The laboratory
reports are provided in Appendix B.
SURVEY OF ASBESTOS-CONTAINING MATERIALS
PINE GROVE PUBLIC SCHOOL
arcadis.com 3-2
Table 3.1: Summary of Laboratory Analyses of Bulk Samples
Pine Grove Public School
Sample No Location Description Asbestos Content
1956 Era of Construction
1A Room 41 Drywall joint compound None detected (1)
1B Room 41 Drywall joint compound None detected (1)
1C Room 41 Drywall joint compound None detected (1)
2A Room 40 Interior door caulking - white <0.25% Chrysotile (PLM) (1)
0.37% Chrysotile (TEM) (1)
2B Room 39 Interior door caulking - white <0.25% Chrysotile (1,4)
2C Room 40 Interior door caulking - white <0.25% Chrysotile (1,4)
3A Room 40 Concrete block mortar None detected (1)
3B Room 39 Concrete block mortar None detected (1)
3C Room 40 Concrete block mortar None detected (1)
4A Room 39 Ceramic block mortar None detected (1)
4B Room 40 Ceramic block mortar None detected (1)
4C Room 39 Ceramic block mortar None detected (1)
5A Room 40 Paint on concrete block None detected (1)
5B Room 39 Paint on concrete block None detected (1)
5C Room 40 Paint on concrete block None detected (1)
15A Exterior Exterior door caulking <0.25% Chrysotile (PLM) (1,4)
0.41% Chrysotile (TEM) (1,4)
15B Exterior Exterior door caulking <0.25% Chrysotile (PLM) (1,4)
15C Exterior Exterior door caulking None detected (1)
16A Exterior Exterior brick mortar None detected (1)
16B Exterior Exterior brick mortar None detected (1)
16C Exterior Exterior brick mortar None detected (1)
1957 Era of Construction
18A Room 18 Paint on concrete block None detected (1)
SURVEY OF ASBESTOS-CONTAINING MATERIALS
PINE GROVE PUBLIC SCHOOL
arcadis.com 3-3
Sample No Location Description Asbestos Content
18B Room 20 Paint on concrete block None detected (1)
18C Room 21 Paint on concrete block None detected (1)
19A Room 18 Concrete block mortar None detected (1)
19B Room 19 Concrete block mortar None detected (1)
19C Corridor 55 Concrete block mortar None detected (1)
1960 Era of Construction
20A Room 22 Concrete block mortar None detected (1)
20B Room 24 Concrete block mortar None detected (1)
20C Corridor 56 Concrete block mortar None detected (1)
21A Room 22 Drywall joint compound None detected (1)
21B Room 23 Drywall joint compound None detected (1)
21C Room 23 Drywall joint compound None detected (1)
22A Room 22 Paint on concrete block None detected (1)
22B Room 23 Paint on concrete block None detected (1)
22C Room 24 Paint on concrete block None detected (1)
23A Room 24 1’x1’ wall tile – 22 holes None detected (1)
23B Room 25 1’x1’ wall tile – 22 holes None detected (1)
23C Room 24 1’x1’ wall tile – 22 holes None detected (1)
24A Corridor 56 1’x1’ ceiling tile adhesive None detected (1)
24B Corridor 56 1’x1’ ceiling tile adhesive None detected (1)
24C Corridor 56 1’x1’ ceiling tile adhesive None detected (1)
1963 Era of Construction
6A Room 4A Interior door caulking - white None detected (PLM) (1)
None detected (TEM) (1)
6B Room 2A Interior door caulking - white None detected (1)
6C Room 4A Interior door caulking - white None detected (1)
7A Room 2A Concrete block mortar <0.25% Chrysotile (Pt Ct) (1,4)
SURVEY OF ASBESTOS-CONTAINING MATERIALS
PINE GROVE PUBLIC SCHOOL
arcadis.com 3-4
Sample No Location Description Asbestos Content
7B Room 4A Concrete block mortar <0.25% Chrysotile (Pt Ct) (1,4)
7C Room 2A Concrete block mortar <0.25% Chrysotile (Pt Ct) (1,4)
8A Room 2A Ceramic block mortar <0.25% Chrysotile (Pt Ct) (1,4)
8B Room 4A Ceramic block mortar <0.25% Chrysotile (Pt Ct) (1,4)
8C Room 2A Ceramic block mortar <0.25% Chrysotile (Pt Ct) (1,4)
9A Room 50 Brick mortar <0.25% Chrysotile (Pt Ct) (1,4)
9B Room 50 Brick mortar <0.25% Chrysotile (Pt Ct) (1,4)
9C Room 50 Brick mortar <0.25% Chrysotile (Pt Ct) (1,4)
10A Room 4A Ceramic tile grout <0.25% Chrysotile (Pt Ct) (1,4)
10B Room 4A Ceramic tile grout <0.25% Chrysotile (Pt Ct) (1,4)
10C Room 4A Ceramic tile grout <0.25% Chrysotile (Pt Ct) (1,4)
11A Room 4A Ceramic tile mortar bed <0.25% Chrysotile (Pt Ct) (1,4)
11B Room 4A Ceramic tile mortar bed <0.25% Chrysotile (Pt Ct) (1,4)
11C Room 4A Ceramic tile mortar bed <0.25% Chrysotile (Pt Ct) (1,4)
12A Room 2A Paint on concrete block None detected (1)
12B Room 4A Paint on concrete block None detected (1)
12C Room 2A Paint on concrete block None detected (1)
13A Exterior Exterior door caulking - grey None detected (1)
13B Exterior Exterior door caulking - grey None detected (1)
13C Exterior Exterior door caulking - grey None detected (1)
14A Exterior Exterior brick mortar None detected (1)
14B Exterior Exterior brick mortar None detected (1)
14C Exterior Exterior brick mortar None detected (1)
15A Corridor 53 2’x4’ ceiling tile – fissure on 2’ None detected (1)
15B Corridor 53 2’x4’ ceiling tile – fissure on 2’ None detected (1)
15C Corridor 53 2’x4’ ceiling tile – fissure on 2’ None detected (1)
16A Room 9 2’x4’ ceiling tile – pinhole small fissure None detected (1)
SURVEY OF ASBESTOS-CONTAINING MATERIALS
PINE GROVE PUBLIC SCHOOL
arcadis.com 3-5
Sample No Location Description Asbestos Content
16B Room 22 2’x4’ ceiling tile – pinhole small fissure None detected (1)
16C Room 36 2’x4’ ceiling tile – pinhole small fissure None detected (1)
17A Room 5 2’x4’ ceiling tile – pinhole random fissure None detected (1)
17B Room 34 2’x4’ ceiling tile – pinhole random fissure None detected (1)
17C Corridor 54 2’x4’ ceiling tile – pinhole random fissure None detected (1)
25A Room 3 Drywall joint compound None detected (1)
25B Room 43 Drywall joint compound None detected (1)
25C Room 45 Drywall joint compound None detected (1)
26A Room 45 1’x1’ wall tile – small in medium holes None detected (1)
26B Room 45 1’x1’ wall tile – small in medium holes None detected (1)
26C Room 45 1’x1’ wall tile – small in medium holes None detected (1)
Unspecified era of construction
1A Room 28 2’ x 4’ Ceiling tile – Random small fissure and
pinhole None detected (2)
1B Room 28 2’ x 4’ Ceiling tile – Random small fissure and
pinhole None detected (2)
1C Room 28 2’ x 4’ Ceiling tile – Random small fissure and
pinhole None detected (2)
2A Room 30A 2’ x 4’ Ceiling tile – Random wide fissure and pinhole None detected (2)
2B Room 30A 2’ x 4’ Ceiling tile – Random wide fissure and pinhole None detected (2)
2C Room 30A 2’ x 4’ Ceiling tile – Random wide fissure and pinhole None detected (2)
3A Room 28 Concrete block mortar None detected (2)
3B Room 30A Concrete block mortar None detected (2)
3C Room 30A Concrete block mortar None detected (2)
4A Room 28 Concrete block filler paint None detected (2)
4B Room 30A Concrete block filler paint None detected (2)
4C Room 30A Concrete block filler paint None detected (2)
5A Room 30A Drywall wall joint compound None detected (2)
SURVEY OF ASBESTOS-CONTAINING MATERIALS
PINE GROVE PUBLIC SCHOOL
arcadis.com 3-6
Sample No Location Description Asbestos Content
5B Room 30A Drywall wall joint compound None detected (2)
5C Room 30A Drywall wall joint compound None detected (2)
6A Room 28 Black paper inside HVAC ductwork None detected (TEM) (2)
6B Room 28 Black paper inside HVAC ductwork None detected (2)
6C Room 28 Black paper inside HVAC ductwork None detected (2)
7A Room 28 Concrete block wall expansion joint caulking – Beige
on grey None detected (2)
7B Room 29 Concrete block wall expansion joint caulking – Beige
on grey None detected (2)
7C Room 30A Concrete block wall expansion joint caulking – Beige
on grey None detected (2)
8A Room 30A Door caulking - Taupe None detected (2)
8B Room 30A Door caulking - Taupe None detected (2)
8C Room 28 Door caulking - Taupe None detected (2)
9A Room 30A 3” Red ceramic cove base tile grout - Brown None detected (2)
9B Room 30A 3” Red ceramic cove base tile grout - Brown None detected (2)
9C Room 28 3” Red ceramic cove base tile grout - Brown None detected (2)
10A Room 30A 3” Red ceramic cove base tile mortar - Grey None detected (2)
10B Room 30A 3” Red ceramic cove base tile mortar - Grey None detected (2)
10C Room 28 3” Red ceramic cove base tile mortar - Grey None detected (2)
1 Area 30A (2’ x 4’) ceiling tile None detected (3)
2 Area 24 12” ceiling tile None detected (3)
3 Area 55 Pipe straight insulation (anti-sweat) 7.3% chrysotile (TEM) (3)
4 Area 55 (2’ x 4’) ceiling tile None detected (3)
5 Area 55 Pipe fitting insulation 57% chrysotile (3)
6 Area 8 (2’ x 4’) ceiling tile None detected (3)
7 Area 3 12” ceiling tile None detected (3)
8 Area 3 Domestic hot water pipe fitting insulation 40% chrysotile (3)
SURVEY OF ASBESTOS-CONTAINING MATERIALS
PINE GROVE PUBLIC SCHOOL
arcadis.com 3-7
Sample No Location Description Asbestos Content
10 Area 46 Rain drain pipe fitting insulation 36% chrysotile (3)
11 Area 33 Domestic water pipe fitting insulation 57% chrysotile (3)
12 Area 33 Boiler breeching insulation 31% chrysotile (3)
13 Area 33 Domestic water pipe straight insulation (anti-sweat) 0.27% chrysotile (3,4)
14 Area 33 Parging material on breeching None detected (3)
15 Area 33 Hot water heating pipe fitting insulation 36% chrysotile (3)
16 Area 54 Pipe straight insulation 57% chrysotile (3)
17 Area 52 (2’ x 4’) ceiling tile None detected (3)
18 Area 54 (2’ x 4’) ceiling tile None detected (3)
19 Area 34 (2’ x 4’) ceiling tile None detected (3)
20 Area 51 (2’ x 4’) ceiling tile None detected (3)
1A Southeast
roof Vermiculite Libby amphibole (5)
NOTES:
(1) Sample results derived from a report prepared by Arcadis for the Halton District School Board entitled Pre-Renovation Designated Substances and Hazardous Materials Survey, Pine Grove Public School, 529 Fourth Line, Oakville, Ontario dated April 11, 2019.
(2) Sample results derived from a report prepared by Arcadis for the Halton District School Board entitled Pre-Renovation Designated Substances and Hazardous Materials Survey, Pine Grove Public School, 529 Fourth Line, Oakville, Ontario dated April 30, 2017.
(3) Sample results derived from a report prepared by DCS (now Arcadis) for the Halton District School Board entitled Survey of Asbestos-Containing Materials, Pine Grove Public School, Oakville dated August 2013.
(4) “Asbestos-containing material” is defined as material that contains 0.5% or more asbestos by dry weight.
(5) Sample collected in August 2017.
Bulk samples were analyzed by Polarized Light Microscopy (PLM) analysis, except where “TEM” is noted, in which case Transmission Electron Microscopy analysis was also performed.
< = less than.
Chrysotile = Chrysotile asbestos. Amosite = Amosite asbestos. Libby amphibole = Libby amphibole asbestos.
SURVEY OF ASBESTOS-CONTAINING MATERIALS
PINE GROVE PUBLIC SCHOOL
arcadis.com
3-8
Table 3.2: Summary of Asbestos-Containing Materials
PINE GROVE PUBLIC SCHOOL
Level Room Material Asbestos
Content
Location
Within Space
Estimated
Quantity
Friable or
Non-Friable Condition Comments
1 1 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
1 1A Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
Pipe fitting insulation 25 to 75% Chrysotile Below ceiling <5 fittings Friable G
1 2 NACMO
1 2A NACMO
1 3 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
1 4 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
1 4A NACMO
1 5 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
1 6 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
1 7 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
1 8 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
1 9 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
1 10 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
1 11 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
1 12 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
SURVEY OF ASBESTOS-CONTAINING MATERIALS
PINE GROVE PUBLIC SCHOOL
arcadis.com
3-9
Level Room Material Asbestos
Content
Location
Within Space
Estimated
Quantity
Friable or
Non-Friable Condition Comments
1 13 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
1 14 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
1 15 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
1 16 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
1 17 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
1 18 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
1 19 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
1 20 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
1 21 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
1 22 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
1 23 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
1 23A Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
Pipe fitting insulation 25 to 75% Chrysotile Below ceiling <5 fittings Friable G
1 24 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
1 25 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
1 26 Vinyl floor tile Assumed asbestos All flooring >100 m2 Non-friable G
1 27 Vinyl floor tile Assumed asbestos All flooring 10-50 m2 Non-friable G
1 28 Cement pipe Assumed asbestos In pipe chase 3-10 m Non-friable G
SURVEY OF ASBESTOS-CONTAINING MATERIALS
PINE GROVE PUBLIC SCHOOL
arcadis.com
3-10
Level Room Material Asbestos
Content
Location
Within Space
Estimated
Quantity
Friable or
Non-Friable Condition Comments
1 29 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
1 30 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
1 30A Cement pipe Assumed asbestos In pipe chase 3-10 m Non-friable G
1 32 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
1 33 Pipe fitting insulation 50 to 75% Chrysotile Below ceiling >20 fittings Friable G
Boiler Breeching 25 to 50% Chrysotile Below ceiling <10 m2 Friable G
1 33A Pipe fitting insulation 25 to 50% Chrysotile Below ceiling 5 fittings Friable G
1 34 NACMO
1 34A NACMO
1 34B NACMO
1 34C Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
1 35 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
1 36 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
1 37 NACMO
1 38 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
1 39 NACMO
1 40 NACMO
1 41 Vinyl floor tile Assumed asbestos All flooring 10-50 m2 Non-friable G
SURVEY OF ASBESTOS-CONTAINING MATERIALS
PINE GROVE PUBLIC SCHOOL
arcadis.com
3-11
Level Room Material Asbestos
Content
Location
Within Space
Estimated
Quantity
Friable or
Non-Friable Condition Comments
1 41C Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
1 42 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G
1 42A Vinyl floor tile Assumed asbestos All flooring 10-50 m2 Non-friable G
Pipe fitting insulation 25 to 50% Chrysotile Above ceiling 5 to 10 fittings Friable G
1 45 NACMO
1 46 Pipe fitting insulation 25 to 75% Chrysotile Below ceiling 10 to 20 fittings Friable G
1 47 NACMO
1 48 NACMO
1 49 Pipe fitting insulation 25 to 75% Chrysotile Above ceiling >20 fittings Friable G
1 50 Pipe fitting insulation 25 to 75% Chrysotile Above ceiling >20 fittings Friable G
1 51 Pipe fitting insulation 25 to 50% Chrysotile Above ceiling 10-20 fittings Friable G
1 52 NACMO
1 53 Pipe fitting insulation 50 to 75% Chrysotile Above ceiling >20 fittings Friable G
Pipe straight insulation 50 to 75% Chrysotile Above ceiling 3-10 m Friable G
1 54 Pipe fitting insulation 50 to 75% Chrysotile Above ceiling >20 fittings Friable G
Pipe straight insulation 50 to 75% Chrysotile Above ceiling 3-10 m Friable G
1 55 Pipe fitting insulation 5 to 75 % Chrysotile Above ceiling >20 fittings Friable G
Pipe straight insulation 5 to 75 % Chrysotile Above ceiling 10-30 m Friable G
SURVEY OF ASBESTOS-CONTAINING MATERIALS
PINE GROVE PUBLIC SCHOOL
arcadis.com
3-12
Level Room Material Asbestos
Content
Location
Within Space
Estimated
Quantity
Friable or
Non-Friable Condition Comments
1 56 NACMO
1 57 NACMO
1 58 NACMO
1 Exterior Cement board Assumed asbestos Exterior fascia 50-100 m2 Non-friable G
Roof Roof Vermiculite Libby amphibole Southeast roof >100 m2 Friable G
NOTES: < = Less than. > = Greater than. Condition: G = Good. F = Fair. P = Poor. NACMO: No Asbestos-Containing Materials Observed.
NOTE!: Asbestos may also be present in locations that are presently inaccessible (e.g., in pipe chases, behind walls, above suspended gypsum board or plaster ceilings, and below carpets).
SURVEY OF ASBESTOS-CONTAINING MATERIALS
PINE GROVE PUBLIC SCHOOL
arcadis.com
4-1
4 DISCUSSION
The owner of a building is required to provide information on the locations of asbestos containing material
to:
i) any person who is an “occupier”(1) of the building. The occupier is then responsible for
providing the information to their own employees;
ii) any prospective constructors, contractors and subcontractors prior to requesting tenders
or arranging for the demolition, alteration or repair of all or part of a building. The
information to be provided shall identify whether any material that is likely to be handled,
dealt with, disturbed or removed is asbestos-containing material; describe the condition of
the material; state whether the material is friable or non-friable; and contain drawings, plans
and specifications, as appropriate, to show the locations of material;
iii) any employer with whom the owner arranges or contracts for work not described in ii) above
that may involve asbestos-containing material or is to be carried out in close proximity to
and may disturb the material;
iv) owner’s staff, if they perform work that involves asbestos-containing material or work that
is to be carried out in close proximity to and may disturb the material.
If material suspected of containing asbestos which is not identified in the asbestos survey records is
discovered during the course of any work in a facility, then either the constructor or the owner is required
to immediately notify (orally and in writing):
a) an inspector at the office of the Ministry of Labour nearest the workplace;
b) the owner;
c) the contractor; and
d) the joint health and safety committee or the health and safety representative.
The owner is also responsible for providing tenderers with a list of designated substances (including
asbestos) at the tendering stage of a project.
This report was prepared as part of the asbestos management program, not for the purposes of construction
or renovation projects. Additional investigation and testing may be required prior to construction or
renovation projects.
Bulk sampling of building materials was carried out in accordance with the minimum sampling requirements
specified in Table 1 of O.Reg. 278/05. We recommend that additional samples of certain types of material
which may have been mixed on site at the time of construction (plaster, drywall joint compound, ceiling
(1) An “occupier” is defined as: (a) a person who is in physical possession of premises, or (b) a person who has responsibility for and control over the condition of premises or the activities carried on there, or
control over persons allowed to enter the premises.
SURVEY OF ASBESTOS-CONTAINING MATERIALS
PINE GROVE PUBLIC SCHOOL
arcadis.com
4-2
texture coat, etc.) be tested for asbestos content prior to the disturbance of these materials at the time of
renovations, alterations or demolition work.
Asbestos may also be present in materials which were not sampled during the course of the asbestos
survey carried out by Arcadis, including, but not limited to, roofing materials, fire doors, mastics or
cementitious levelling compound under vinyl flooring, acoustic ceiling tile adhesive, grout, caulking, gaskets
in piping, internal components of boilers, paints and coatings, components of electrical equipment, (e.g. –
electrical wiring insulation, non-metallic sheathed cable, electrical panel partitions, arc chutes, high-grade
electrical paper, etc.), concrete, etc., and/or in locations that are presently inaccessible (e.g., in pipe chases,
behind walls, above suspended gypsum board or plaster ceilings, and below carpets). Asbestos may also
be present in the form of vermiculite insulation in cavities in concrete or cement block walls (used as in-fill
insulation). Confirmatory testing of any such materials could be undertaken as the need arises (i.e., at the
time of renovations, modifications or demolition) or the materials can be assumed to contain asbestos
based on findings in adjacent areas.
As noted above, if any materials which may contain asbestos and which were not tested during the course
of the asbestos survey are discovered during any construction activities, the work shall not proceed until
such time as the required notifications have been made and an appropriate course of action is determined.
SURVEY OF ASBESTOS-CONTAINING MATERIALS
PINE GROVE PUBLIC SCHOOL
arcadis.com
5-1
5 USE AND LIMITATIONS OF THIS REPORT
This report, prepared for Halton District School Board and does not provide certification or warranty,
expressed or implied, that the investigation conducted by Arcadis identified all asbestos-containing
materials present in the subject facilities. The work undertaken by Arcadis was directed to provide
information on the presence of asbestos-containing building materials based on visual inspection of readily
accessible areas of the building and on the results of laboratory analysis of bulk samples of material
gathered in the course of the visual inspection. The survey did not include for identification of asbestos in
process materials, equipment (including electrical equipment and wiring), furniture (e.g., chairs, table tops,
chalkboards, etc.), nor material outside of the building (e.g. asphaltic pavement).
This report was prepared by Arcadis for Halton District School Board. Any use which a third party makes
of the report, or reliance on, or decisions to be based on it, is the responsibility of such third parties.
APPENDIX A Floor Plans
NOTES:
REVISIONS:
No. Date: By: Revisions
REFERENCE:
1.
1.
LEGEND:
FUNCTIONAL SPACE
THROUGHOUT FUNCTIONAL SPACE
ABOVE CEILING ASSEMBLY
NOTE:
REFER TO ROOM-BY-ROOM
DATA SHEETS
FOR SPECIFIC LOCATIONS OF
ASBESTOS
CEMENT PRODUCTS.
HALTON DISTRICT SCHOOL BOARD
LOCATION OF ASBESTOS CONTAINING
MATERIALS
PINE GROVE PUBLIC SCHOOL
529 FOURTH LINE, OAKVILLE, ON
BASEMENT
DEC 2019
N.T.S
G.E.C. A.N.
30038950
Drawn By:
Date:
Scale:
Approved By:
Drawing No:
Project No:
30038950-2
HALTON DISTRICT SCHOOL BOARD
LOCATION OF ASBESTOS CONTAINING
MATERIALS
PINE GROVE PUBLIC SCHOOL
529 FOURTH LINE, OAKVILLE, ON
FIRST FLOOR
DEC 2019
N.T.S
G.E.C. A.N.
30038950
Drawn By:
Date:
Scale:
NOTES:
REVISIONS:
No. Date: By: Revisions
REFERENCE:
1.
1.
Approved By:
Drawing No:
Project No:
LEGEND:
FUNCTIONAL SPACE
THROUGHOUT FUNCTIONAL SPACE
ABOVE CEILING ASSEMBLY
ASBESTOS ON PIPING (FRIABLE)
ASBESTOS ON PIPE FITTINGS ONLY
(FRIABLE)
ASBESTOS ON MECHANICAL
EQUIPMENT (FRIABLE)
ASSUMED ASBESTOS FLOOR TILE
(NON-FRIABLE)
ASBESTOS CEMENT PRODUCT
30038950-1
ASBESTOS-CONTAINING VERMICULITE
IS PRESENT IN ROOFING MATERIAL.
ASSUMED ASBESTOS-CONTAINING
CEMENT BOARD ON EXTERIOR FASCIA
THROUGHOUT THE BUILDING.
APPENDIX B Laboratory Reports
EMSL Canada Inc.
2756 Slough Street Mississauga, ON L4T 1G3
Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]
55DCSL97551902614
702170-193
EMSL Canada Order ID:
Customer ID:
Customer PO:
Project ID:
Attn:
Proj: Pine Grove Ps / 702170-193
Phone: (905) 882-5984
Fax: (905) 882-8962
Collected:
Received: 3/06/2019
Analyzed: 3/28/2019
Dwayne Kellyman
ARCADIS Canada Inc.
121 Granton Drive
Unit 12
Richmond Hill, ON L4B 3N4
Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via
EPA600/R-93/116 Method
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-00011A
Era 1956 - Room 41/Drywall Joint Compound
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0%PLM White None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-00021B
Era 1956 - Room 41/Drywall Joint Compound
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0%PLM White None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-00031C
Era 1956 - Room 41/Drywall Joint Compound
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0%PLM White None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-00042A
Era 1956 - Room 40/Interior Door Caulking - white
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/12/2019 0.0% <0.25%100% ChrysotilePLM Grav. Reduction Blue/Green
3/13/2019 0.00% 99.63% ChrysotileTEM Grav. Reduction Blue/Green 0.37%
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-00052B
Era 1956 - Room 39/Interior Door Caulking - white
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0% <1% ChrysotilePLM Green
3/28/2019 0.0% <0.25%100% ChrysotilePLM Grav. Reduction Green
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-00062C
Era 1956 - Room 40/Interior Door Caulking - white
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0% <1% ChrysotilePLM Green
3/28/2019 0.0% <0.25%100% ChrysotilePLM Grav. Reduction Green
Test Report:EPAMultiTests-7.32.2.D Printed: 3/28/2019 02:54PM Page 1 of 12
EMSL Canada Inc.
2756 Slough Street Mississauga, ON L4T 1G3
Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]
55DCSL97551902614
702170-193
EMSL Canada Order ID:
Customer ID:
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via
EPA600/R-93/116 Method
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-00073A
Era 1956 - Room 40/Concrete Block Mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-00083B
Era 1956 - Room 39/Concrete Block Mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-00093C
Era 1956 - Room 40/Concrete Block Mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-00104A
Era 1956 - Room 39/Ceramic Block Mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0%PLM Gray/White Inseparable layers.None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-00114B-Mortar
Era 1956 - Room 40/Ceramic Block Mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-0011A4B-Grout
Era 1956 - Room 40/Ceramic Block Mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0%PLM White None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-00124C
Era 1956 - Room 39/Ceramic Block Mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0%PLM Gray Inseparable layers.None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-00135A
Era 1956 - Room 40/Paint on Concrete Block
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0%PLM Gray/White None Detected
Test Report:EPAMultiTests-7.32.2.D Printed: 3/28/2019 02:54PM Page 2 of 12
EMSL Canada Inc.
2756 Slough Street Mississauga, ON L4T 1G3
Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]
55DCSL97551902614
702170-193
EMSL Canada Order ID:
Customer ID:
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via
EPA600/R-93/116 Method
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-00145B
Era 1956 - Room 39/Paint on Concrete Block
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0%PLM Gray/White None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-00155C
Era 1956 - Room 40/Paint on Concrete Block
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0%PLM White None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-001615A
Era 1956 - Exterior/Exterior Door Caulking
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/12/2019 0.0% <0.25%100% ChrysotilePLM Grav. Reduction Blue/Green
3/13/2019 0.00% 99.59% ChrysotileTEM Grav. Reduction Blue/Green 0.41%
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-001715B
Era 1956 - Exterior/Exterior Door Caulking
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0% <1% ChrysotilePLM Gray
3/28/2019 0.0% <0.25%100% ChrysotilePLM Grav. Reduction Green
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-001815C
Era 1956 - Exterior/Exterior Door Caulking
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-001916A
Era 1956 - Exterior/Exterior Brick Mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-002016B
Era 1956 - Exterior/Exterior Brick Mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-002116C
Era 1956 - Exterior/Exterior Brick Mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0%PLM Gray None Detected
Test Report:EPAMultiTests-7.32.2.D Printed: 3/28/2019 02:54PM Page 3 of 12
EMSL Canada Inc.
2756 Slough Street Mississauga, ON L4T 1G3
Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]
55DCSL97551902614
702170-193
EMSL Canada Order ID:
Customer ID:
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via
EPA600/R-93/116 Method
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-00226A
Era 1963 - Room 4A/Interior Door Caulking - white
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/12/2019 0.0% 100%PLM Grav. Reduction None DetectedWhite
3/13/2019 0.0% 100.0%TEM Grav. Reduction None DetectedWhite
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-00236B
Era 1963 - Room 2A/Interior Door Caulking - white
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0%PLM White None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-00246C
Era 1963 - Room 4A/Interior Door Caulking - white
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0%PLM White None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-00257A
Era 1963 - Room 2A/Concrete Block Mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0% <1% ChrysotilePLM Gray
3/13/2019 0.0% 100.0% <0.25% Chrysotile400 PLM Pt Ct Gray
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-00267B
Era 1963 - Room 4A/Concrete Block Mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0% <1% ChrysotilePLM Gray
3/13/2019 0.00% 99.75% 0.25% Chrysotile400 PLM Pt Ct Gray
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-00277C
Era 1963 - Room 2A/Concrete Block Mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0% <1% ChrysotilePLM Gray
3/13/2019 0.0% 100.0% <0.25% Chrysotile400 PLM Pt Ct Gray
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-00288A
Era 1963 - Room 2A/Ceramic Block Mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0% <1% ChrysotilePLM Gray
3/13/2019 0.0% 100.0% <0.25% Chrysotile400 PLM Pt Ct Gray
Test Report:EPAMultiTests-7.32.2.D Printed: 3/28/2019 02:54PM Page 4 of 12
EMSL Canada Inc.
2756 Slough Street Mississauga, ON L4T 1G3
Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]
55DCSL97551902614
702170-193
EMSL Canada Order ID:
Customer ID:
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via
EPA600/R-93/116 Method
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-00298B
Era 1963 - Room 4A/Ceramic Block Mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0% <1% ChrysotilePLM Gray
3/13/2019 0.0% 100.0% <0.25% Chrysotile400 PLM Pt Ct Gray
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-00308C
Era 1963 - Room 2A/Ceramic Block Mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0% <1% ChrysotilePLM Gray
3/13/2019 0.0% 100.0% <0.25% Chrysotile400 PLM Pt Ct Gray
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-00319A
Era 1963 - Room 50/Brick Mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0% <1% ChrysotilePLM Gray
3/13/2019 0.0% 100.0% <0.25% Chrysotile400 PLM Pt Ct Gray
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-00329B
Era 1963 - Room 50/Brick Mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0% <1% ChrysotilePLM Gray
3/13/2019 0.0% 100.0% <0.25% Chrysotile400 PLM Pt Ct Gray
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-00339C
Era 1963 - Room 50/Brick Mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0% <1% ChrysotilePLM Gray
3/13/2019 0.0% 100.0% <0.25% Chrysotile400 PLM Pt Ct Gray
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-003410A
Era 1963 - Room 4A/Ceramic Tile Grout
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0% <1% ChrysotilePLM White
3/13/2019 0.0% 100.0% <0.25% Chrysotile400 PLM Pt Ct White
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-003510B
Era 1963 - Room 4A/Ceramic Tile Grout
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0% <1% ChrysotilePLM White
3/13/2019 0.0% 100.0% <0.25% Chrysotile400 PLM Pt Ct White
Test Report:EPAMultiTests-7.32.2.D Printed: 3/28/2019 02:54PM Page 5 of 12
EMSL Canada Inc.
2756 Slough Street Mississauga, ON L4T 1G3
Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]
55DCSL97551902614
702170-193
EMSL Canada Order ID:
Customer ID:
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via
EPA600/R-93/116 Method
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-003610C
Era 1963 - Room 4A/Ceramic Tile Grout
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0% <1% ChrysotilePLM White
3/13/2019 0.0% 100.0% <0.25% Chrysotile400 PLM Pt Ct White
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-003711A
Era 1963 - Room 4A/Ceramic Tile Mortar Bed
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0% <1% ChrysotilePLM Gray/White
3/13/2019 0.0% 100.0% <0.25% Chrysotile400 PLM Pt Ct Gray/White
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-003811B
Era 1963 - Room 4A/Ceramic Tile Mortar Bed
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0% <1% ChrysotilePLM Gray/White
3/13/2019 0.00% 99.75% 0.25% Chrysotile400 PLM Pt Ct Gray/White
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-003911C
Era 1963 - Room 4A/Ceramic Tile Mortar Bed
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0% <1% ChrysotilePLM White
3/13/2019 0.00% 99.75% 0.25% Chrysotile400 PLM Pt Ct White
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-004012A
Era 1963 - Room 2A/Paint on concrete block
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0%PLM Gray/White None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-004112B
Era 1963 - Room 2A/Paint on concrete block
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0%PLM Gray/White None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-004212C
Era 1963 - Room 2A/Paint on concrete block
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0%PLM Gray/White None Detected
Test Report:EPAMultiTests-7.32.2.D Printed: 3/28/2019 02:54PM Page 6 of 12
EMSL Canada Inc.
2756 Slough Street Mississauga, ON L4T 1G3
Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]
55DCSL97551902614
702170-193
EMSL Canada Order ID:
Customer ID:
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via
EPA600/R-93/116 Method
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-004313A
Era 1963 - Exterior/Exterior Door Caulking - Grey
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/12/2019 0.0% 100%PLM Grav. Reduction None DetectedGray
3/13/2019 0.0% 100.0%TEM Grav. Reduction None DetectedGray
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-004413B
Era 1963 - Exterior/Exterior Door Caulking - Grey
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-004513C
Era 1963 - Exterior/Exterior Door Caulking - Grey
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-004614A
Era 1963 - Exterior/Exterior Brick Mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-004714B
Era 1963 - Exterior/Exterior Brick Mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-004814C
Era 1963 - Exterior/Exterior Brick Mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/13/2019 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-004915A
Corridor 53/2x4 ceiling tile - fissure on 2
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 90.0% 10.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-005015B
Corridor 53/2x4 ceiling tile - fissure on 2
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 90.0% 10.0%PLM Gray None Detected
Test Report:EPAMultiTests-7.32.2.D Printed: 3/28/2019 02:54PM Page 7 of 12
EMSL Canada Inc.
2756 Slough Street Mississauga, ON L4T 1G3
Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]
55DCSL97551902614
702170-193
EMSL Canada Order ID:
Customer ID:
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via
EPA600/R-93/116 Method
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-005115C
Corridor 53/2x4 ceiling tile - fissure on 2
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 90.0% 10.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-005216A
Room 9/2x4 ceiling tile - pinhole small fissure
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 90.0% 10.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-005316B
Room 22/2x4 ceiling tile - pinhole small fissure
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 90.0% 10.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-005416C
Room 36/2x4 ceiling tile - pinhole small fissure
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 75.0% 25.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-005517A
Room 5/2x4 ceiling tile - pinhole random fissure
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 90.0% 10.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-005617B
Room 34/2x4 ceiling tile - pinhole random fissure
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 90.0% 10.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-005717C
Corridor 54/2x4 ceiling tile - pinhole random fissure
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 75.0% 25.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-005818A
Era 1957-Room 18/Paint on concrete block
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 0.0% 100.0%PLM Gray/White None Detected
Test Report:EPAMultiTests-7.32.2.D Printed: 3/28/2019 02:54PM Page 8 of 12
EMSL Canada Inc.
2756 Slough Street Mississauga, ON L4T 1G3
Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]
55DCSL97551902614
702170-193
EMSL Canada Order ID:
Customer ID:
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via
EPA600/R-93/116 Method
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-005918B
Era 1957-Room 20/Paint on concrete block
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 0.0% 100.0%PLM White None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-006018C
Era 1957-Room 21/Paint on concrete block
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 0.0% 100.0%PLM Gray/White/Green Result includes a small amount of
inseparable attached materialNone Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-006119A
Era 1957-Room 18/Concrete block mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-006219B
Era 1957-Room 19/Concrete block mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-006319C
Era 1957-Corridor 55/Concrete block mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-006420A
Era 1960-Room 22/Concrete block mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-006520B
Era 1960-Room 24/Concrete block mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-006620C
Era 1960-Corridor 56/Concrete block mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 0.0% 100.0%PLM Gray None Detected
Test Report:EPAMultiTests-7.32.2.D Printed: 3/28/2019 02:54PM Page 9 of 12
EMSL Canada Inc.
2756 Slough Street Mississauga, ON L4T 1G3
Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]
55DCSL97551902614
702170-193
EMSL Canada Order ID:
Customer ID:
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via
EPA600/R-93/116 Method
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-006721A
Era 1960-Room 22/Drywall Joint Compound
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 0.0% 100.0%PLM White None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-006821B
Era 1960-Room 23/Drywall Joint Compound
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 0.0% 100.0%PLM White None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-006921C
Era 1960-Room 23/Drywall Joint Compound
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 0.0% 100.0%PLM White limited sample providedNone Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-007022A
Era 1960-Room 22/Paint on concrete block
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 0.0% 100.0%PLM White None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-007122B
Era 1960-Room 23/Paint on concrete block
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 0.0% 100.0%PLM White None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-007222C
Era 1960-Room 24/Paint on concrete block
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 0.0% 100.0%PLM White None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-007323A
Era 1960-Room 24/1x1 wall tile - 22 holes
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 90.0% 10.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-007423B
Era 1960-Room 25/1x1 wall tile - 22 holes
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 90.0% 10.0%PLM Gray None Detected
Test Report:EPAMultiTests-7.32.2.D Printed: 3/28/2019 02:54PM Page 10 of 12
EMSL Canada Inc.
2756 Slough Street Mississauga, ON L4T 1G3
Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]
55DCSL97551902614
702170-193
EMSL Canada Order ID:
Customer ID:
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via
EPA600/R-93/116 Method
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-007523C
Era 1960-Room 24/1x1 wall tile - 22 holes
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 75.0% 25.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-007624A
Era 1960-Corridor 56/1x1 ceiling tile adhesive
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 0.0% 100.0%PLM Brown None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-007724B
Era 1960-Corridor 56/1x1 ceiling tile adhesive
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 0.0% 100.0%PLM Brown None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-007824C
Era 1960-Corridor 56/1x1 ceiling tile adhesive
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 0.0% 100.0%PLM Brown None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-007925A
Era 1963-Room 3/Drywall Joint Compound
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 0.0% 100.0%PLM White None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-008025B
Era 1963-Room 43/Drywall Joint Compound
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 0.0% 100.0%PLM White None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-008125C
Era 1963-Room 45/Drywall Joint Compound
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 0.0% 100.0%PLM White None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-008226A
Era 1963-Room 45/1x1 wall tile - small in medium holes
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 90.0% 10.0%PLM Gray None Detected
Test Report:EPAMultiTests-7.32.2.D Printed: 3/28/2019 02:54PM Page 11 of 12
EMSL Canada Inc.
2756 Slough Street Mississauga, ON L4T 1G3
Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]
55DCSL97551902614
702170-193
EMSL Canada Order ID:
Customer ID:
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via
EPA600/R-93/116 Method
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-008326B
Era 1963-Room 45/1x1 wall tile - small in medium holes
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 90.0% 10.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551902614-008426C
Era 1963-Room 45/1x1 wall tile - small in medium holes
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/25/2019 80.0% 20.0%PLM Gray None Detected
Analyst(s):
PLM (16)
400 PLM Pt Ct (5)
TEM Grav. Reduction (4)
Caroline Allen
PLM (56)
400 PLM Pt Ct (10)
PLM Grav. Reduction (3)
Harman Sohi
PLM (9)
PLM Grav. Reduction (4)
Natalie D'Amico
Matthew Davis or other approved signatory
or Other Approved Signatory
Reviewed and approved by:
None Detected = <0.1%. EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported above and may
not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical
method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless
otherwise noted. This report must not be used to claim product endorsement by NVLAP of any agency of the U.S. Government.
Samples analyzed by EMSL Canada Inc. Mississauga, ON NVLAP Lab Code 200877-0Report amended: 03/25/201915:10:33 Replaces initial report from: 03/13/201917:12:44 Reason Code: Client-Samples Added
Test Report:EPAMultiTests-7.32.2.D Printed: 3/28/2019 02:54PM Page 12 of 12
Sample Description TEM Result Notes
Test Report:Qualitative Asbestos Analysis by Transmission Electron Microscopy (TEM) and Filtration Technique
Attn: Ryan FarnsworthARCADIS Canada Inc.121 Granton DriveUnit 12Richmond Hill, ON L4B 3N4
Received: 08/01/17 2:43 PM
702170-114/PINEGROOVE P.S
Fax: (905) 882-8962Phone: (905) 882-5984
Project:
8/2/2017Analysis Date:Collected:
EMSL Canada Inc.2756 Slough Street, Mississauga, ON L4T 1G3Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com [email protected]
551708539CustomerID: 55DCSL97CustomerPO: 702170-114ProjectID:
EMSL Canada Or
1A551708539-0001
VERMICULITE- WHITE/BLACK COLOUR FROM SOUTH EAST ROOF
Libby Amphibole
1B551708539-0002
VERMICULITE- WHITE/BLACK COLOUR FROM SOUTH EAST ROOF
Not Analyzed
1C551708539-0003
VERMICULITE- WHITE/BLACK COLOUR FROM SOUTH EAST ROOF
Not Analyzed
Matthew Davisor other approved signatory
Test Report TEMQual-7.21.0 Printed: 8/2/2017 2:34:05 PM 1
Analyst(s)
THIS IS THE LAST PAGE OF THE REPORT.
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported above and may not reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This is a qualitative screen only. Samples received in good condition unless otherwise noted.Samples analyzed by EMSL Canada Inc. Mississauga, ON
Natalie D'Amico (1)
Initial report from 08/02/2017 14:34:05
EMSL Canada Inc.
2756 Slough Street Mississauga, ON L9T 5N4
Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]
55DCSL97551704130
702170-114
EMSL Canada Order ID:
Customer ID:
Customer PO:
Project ID:
Attn:
Proj: Pine Grove/702170-114
Phone: (905) 882-5984
Fax: (905) 882-8962
Collected:
Received: 4/19/2017
Analyzed: 4/22/2017
Sean Parliament
ARCADIS Canada Inc.
121 Granton Drive
Unit 12
Richmond Hill, ON L4B 3N4
Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via
EPA600/R-93/116 Method
Client Sample ID:
Sample Description:
Lab Sample ID: 551704130-00011A
Room 28/2’ x 4’ Ceiling tile – Random small fissure and pinhole
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
4/22/2017 80% 20%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551704130-00021B
Room 28/2’ x 4’ Ceiling tile – Random small fissure and pinhole
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
4/22/2017 80% 20%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551704130-00031C
Room 28/2’ x 4’ Ceiling tile – Random small fissure and pinhole
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
4/22/2017 80% 20%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551704130-00042A
Room 30A/2’ x 4’ Ceiling tile – Random wide fissure and pinhole
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
4/22/2017 80% 20%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551704130-00052B
Room 30A/2’ x 4’ Ceiling tile – Random wide fissure and pinhole
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
4/22/2017 80% 20%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551704130-00062C
Room 30A/2’ x 4’ Ceiling tile – Random wide fissure and pinhole
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
4/22/2017 80% 20%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551704130-00073A
Room 28/Concrete block mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
4/22/2017 0% 100%PLM Gray None Detected
Test Report:EPAMultiTests-7.32.2.D Printed: 4/22/2017 01:17PM Page 1 of 5
EMSL Canada Inc.
2756 Slough Street Mississauga, ON L9T 5N4
Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]
55DCSL97551704130
702170-114
EMSL Canada Order ID:
Customer ID:
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via
EPA600/R-93/116 Method
Client Sample ID:
Sample Description:
Lab Sample ID: 551704130-00083B
Room 30A/Concrete block mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
4/22/2017 0% 100%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551704130-00093C
Room 30A/Concrete block mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
4/22/2017 0% 100%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551704130-00104A
Room 28/Concrete block filler paint
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
4/22/2017 0% 100%PLM White None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551704130-00114B
Room 30A/Concrete block filler paint
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
4/22/2017 0% 100%PLM White None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551704130-00124C
Room 30A/Concrete block filler paint
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
4/22/2017 0% 100%PLM White None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551704130-00135A
Room 30A/Drywall wall joint compound
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
4/22/2017 0% 100%PLM White None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551704130-00145B
Room 30A/Drywall wall joint compound
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
4/22/2017 0% 100%PLM White None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551704130-00155C
Room 30A/Drywall wall joint compound
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
4/22/2017 0% 100%PLM White None Detected
Test Report:EPAMultiTests-7.32.2.D Printed: 4/22/2017 01:17PM Page 2 of 5
EMSL Canada Inc.
2756 Slough Street Mississauga, ON L9T 5N4
Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]
55DCSL97551704130
702170-114
EMSL Canada Order ID:
Customer ID:
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via
EPA600/R-93/116 Method
Client Sample ID:
Sample Description:
Lab Sample ID: 551704130-00166A
Room 28/Black paper inside HVAC ductwork
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
4/21/2017 0.0% 100%PLM Grav. Reduction None DetectedBlack
4/22/2017 0.0% 100%TEM Grav. Reduction None DetectedBlack
Client Sample ID:
Sample Description:
Lab Sample ID: 551704130-00176B
Room 28/Black paper inside HVAC ductwork
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
4/22/2017 70% 30%PLM Black/Yellow None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551704130-00186C
Room 28/Black paper inside HVAC ductwork
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
4/22/2017 70% 30%PLM Black/Yellow None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551704130-00197A
Room 28/Concrete block wall expansion joint caulking – Beige on grey
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
4/22/2017 0% 100%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551704130-00207B
Room 29/Concrete block wall expansion joint caulking – Beige on grey
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
4/22/2017 0% 100%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551704130-00217C
Room 30A/Concrete block wall expansion joint caulking – Beige on grey
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
4/22/2017 0% 100%PLM Beige None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551704130-00228A
Room 30A/Door caulking - Taupe
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
4/22/2017 0% 100%PLM White None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551704130-00238B
Room 30A/Door caulking - Taupe
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
4/22/2017 2% 98%PLM White None Detected
Test Report:EPAMultiTests-7.32.2.D Printed: 4/22/2017 01:17PM Page 3 of 5
EMSL Canada Inc.
2756 Slough Street Mississauga, ON L9T 5N4
Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]
55DCSL97551704130
702170-114
EMSL Canada Order ID:
Customer ID:
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via
EPA600/R-93/116 Method
Client Sample ID:
Sample Description:
Lab Sample ID: 551704130-00248C
Room 28 /Door caulking - Taupe
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
4/22/2017 0% 100%PLM White None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551704130-00259A
Room 30A/3” Red ceramic cove base tile grout - Brown
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
4/22/2017 0% 100%PLM Brown None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551704130-00269B
Room 30A/3” Red ceramic cove base tile grout - Brown
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
4/22/2017 0% 100%PLM Brown None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551704130-00279C
Room 28 /3” Red ceramic cove base tile grout - Brown
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
4/22/2017 0% 100%PLM Brown None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551704130-002810A
Room 30A/3” Red ceramic cove base tile mortar - Grey
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
4/22/2017 0% 100%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551704130-002910B
Room 30A/3” Red ceramic cove base tile mortar - Grey
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
4/22/2017 0% 100%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 551704130-003010C
Room 28 /3” Red ceramic cove base tile mortar - Grey
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
4/22/2017 0% 100%PLM Gray None Detected
Test Report:EPAMultiTests-7.32.2.D Printed: 4/22/2017 01:17PM Page 4 of 5
EMSL Canada Inc.
2756 Slough Street Mississauga, ON L9T 5N4
Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]
55DCSL97551704130
702170-114
EMSL Canada Order ID:
Customer ID:
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via
EPA600/R-93/116 Method
Analyst(s):
PLM (20)
PLM Grav. Reduction (1)
John Biesiadecki
TEM Grav. Reduction (1)Natalie D'Amico
PLM (9)Shorthri Kalikutty
Matthew Davis
or Other Approved Signatory
Reviewed and approved by:
None Detected = <0.1%. EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported above and may
not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical
method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless
otherwise noted. This report must not be used to claim product endorsement by NVLAP of any agency of the U.S. Government.
Samples analyzed by EMSL Canada Inc. Mississauga, ON NVLAP Lab Code 200877-0Initial report from: 04/22/201713:17:19
Test Report:EPAMultiTests-7.32.2.D Printed: 4/22/2017 01:17PM Page 5 of 5
APPENDIX C Sample List of Suspect Asbestos-Containing Building Materials from A Guide to the Regulation Respecting Asbestos on Construction Projects and in Buildings and Repair Operations
1
APPENDIX C
SAMPLE LIST OF SUSPECT ASBESTOS-CONTAINING BUILDING MATERIALS There are an estimated 3,000 products that contain asbestos. In Ontario, asbestos was widely used in sprayed-on material and in pipe and boiler insulation until 1973(1). The use of many other asbestos-containing materials continued until the mid-1980s. Asbestos is still used in the manufacture of a limited number of products, including some floor tiles, cement products, friction materials and textiles. The following list was adapted from the United States Environmental Protection Agency’s (EPA) Sample List of Suspect Asbestos Containing Materials(2). It is not an all inclusive list but is intended as a general guide to show which types of building materials may contain asbestos.
Possible Asbestos-Containing Materials in Buildings
• Acoustical Plaster • Elevator Equipment Panels
• Adhesives • Fire Doors
• Asphalt Floor Tile • Fireproofing Materials
• Base Flashing • Flooring Backing
• Blown-in (Loose Fill) Insulation • Heating and Electrical Ducts
• Boiler Insulation • High Temperature Gaskets
• Breaching Insulation • HVAC Duct Insulation
• Caulking/Putties • Joint Compounds
• Ceiling Tiles and Lay-in Panels • Pipe Insulation (corrugated air-cell,
• Cement Pipes • block, etc.)
• Cement Siding • Roofing Felt
• Cement Wallboard • Roofing Shingles
• Construction Mastics (floor tile, • Spackling Compounds
• carpet, ceiling tile, etc.) • Sprayed-on Insulation
• Cooling Towers • Taping Compounds (thermal)
• Decorative Plaster • Textured Paper Products
• Ductwork Flexible Fabric Connections • Vinyl Floor Tile
• Electrical Cloth • Vinyl Sheet Flooring
• Electrical Wiring Insulation • Vinyl Wall Coverings
• Elevator Brake Shoes • Wallboard
(1) J.S. Dupre, J.F. Mustard & R.J. Uffin, Report of the Royal Commission on Matters of Health and Safety Arising from the Use
of Asbestos in Ontario, Ontario Ministry of the Attorney General, Toronto, Ontario, 1984, page 12. (2) U.S. Environmental Protection Agency, http://www.epa.gov/Region06/6pd/asbestos/asbmatl.htm.
Arcadis Canada Inc.
121 Granton Drive, Suite 12, Richmond Hill, Ontario L4B 3N4
Tel 905 882 5984
Fax 905 882 8962
www.arcadis.com