52
, HALTON DISTRICT SCHOOL BOARD SURVEY OF ASBESTOS- CONTAINING MATERIALS PINE GROVE PUBLIC SCHOOL 529 FOURTH LINE, OAKVILLE, ONTARIO Updated February 10, 2020 30038950

SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

,

HALTON DISTRICT SCHOOL BOARD

SURVEY OF ASBESTOS-CONTAINING MATERIALS

PINE GROVE PUBLIC SCHOOL

529 FOURTH LINE, OAKVILLE, ONTARIO

Updated February 10, 2020

30038950

Page 2: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

SURVEY OF ASBESTOS-CONTAINING MATERIALS

PINE GROVE PUBLIC SCHOOL

arcadis.com i

SURVEY OF ASBESTOS-CONTAINING MATERIALS

PINE GROVE PUBLIC SCHOOL

529 Fourth Line, Oakville, Ontario

Prepared for:

Halton District School Board

J.W. Singleton Education Centre

2050 Guelph Line

Burlington, ON L7P 5A8

Attention: Terry DeMedeiros

Regional Supervisor, Facilities Maintenance

Prepared by:

Arcadis Canada Inc.

121 Granton Drive, Suite 12

Richmond Hill, Ontario L4B 3N4

Tel 905 764 9380

Our Ref.:

30038950

Date:

February 10, 2020

This document is intended only for the use of

the individual or entity for which it was

prepared and may contain information that is

privileged, confidential and exempt from

disclosure under applicable law. Any

dissemination, distribution or copying of this

document is strictly prohibited.

Shubham Shringi, B.Eng., E.I.T.

Environmental Specialist

Ada Nguyen, B.Sc., CIH

Project Manager, Industrial Hygienist

Page 3: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

SURVEY OF ASBESTOS-CONTAINING MATERIALS

PINE GROVE PUBLIC SCHOOL

arcadis.com ii

CONTENTS

1 INTRODUCTION ................................................................................................................................ 1-1

2 METHODOLOGY ............................................................................................................................... 2-1

2.1 Survey ........................................................................................................................................ 2-1

2.2 Assessment ................................................................................................................................ 2-1

3 SURVEY RESULTS ........................................................................................................................... 3-1

4 DISCUSSION ..................................................................................................................................... 4-1

5 USE AND LIMITATIONS OF THIS REPORT .................................................................................... 5-1

TABLES

Table 1.1 Bulk Material Samples (from O.Reg. 278/05) .................................................................. 1-2

Table 3.1 Summary of Laboratory Analyses of Bulk Samples ......................................................... 3-2

Table 3.2 Summary of Asbestos-Containing Materials ................................................................... 3-8

APPENDICES

Appendix A Floor Plans

Appendix B Laboratory Reports

Appendix C Sample List of Suspect Asbestos-Containing Building Materials from A Guide to

the Regulation Respecting Asbestos on Construction Projects and in Buildings

and Repair Operations

Page 4: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

SURVEY OF ASBESTOS-CONTAINING MATERIALS

PINE GROVE PUBLIC SCHOOL

arcadis.com 1-1

1 INTRODUCTION

Arcadis Canada Inc. (Arcadis) was retained by the Halton District School Board to provide an updated

survey of the locations of asbestos-containing materials at Pine Grove Public School located at 529 Fourth

Line in Oakville, Ontario following asbestos remediation associated with the renovation project in July 2019.

Asbestos has been widely used in buildings, both in friable applications (materials which can be easily

crumbled such as pipe and tank insulation, sprayed-on fireproofing and acoustic and texture coat

applications) and in non-friable materials such as floor tile, fire-rated ceiling tile, gaskets, cement board,

cement pipe, drywall joint compound and so on. Plaster applications (walls, ceilings, bulkheads, etc.) may

also contain asbestos. The use of asbestos in friable applications was curtailed in Ontario around the

mid-1970s. Most buildings constructed prior to about the mid-1970s contain some form of friable

asbestos-containing material. The use of asbestos in certain non-friable products continued beyond the

1970s. A sample list of suspect asbestos containing building materials is provided in Appendix C.

Control of exposure to asbestos is governed in Ontario by Regulation 278/05 - Designated Substance -

Asbestos on Construction Projects and in Buildings and Repair Operations. Disposal of asbestos waste

(friable and non-friable materials) is governed by Ontario Regulation 278/05 and by Ontario Regulation 347,

Waste Management - General.

The major requirements of O.Reg. 278/05 with respect to asbestos surveys and assessments are as

follows:

Survey Records:

• non-friable asbestos-containing materials (e.g., vinyl floor tiles, ceiling tiles, drywall joint

compound, plaster, etc.) are to be included in asbestos survey records effective

1 November 2007;

• asbestos survey records are to be updated:

(a) at least once in every 12-month period;

(b) whenever the owner becomes aware of new information; and

• asbestos-containing materials are to be inspected at reasonable intervals in order to

determine their condition.

Bulk Samples:

• the minimum number of bulk samples to be collected from an area of homogeneous

material is set out in Table 1 of the Regulation (Table 1 is reproduced below).

• if analysis establishes that a bulk material sample contains 0.5 per cent or more asbestos

by dry weight:

(a) it is not necessary to analyze other bulk material samples taken from the same

area of homogeneous material; and

(b) the entire area of homogeneous material from which the bulk materials sample

was taken is deemed to be asbestos-containing material.

Page 5: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

SURVEY OF ASBESTOS-CONTAINING MATERIALS

PINE GROVE PUBLIC SCHOOL

arcadis.com 1-2

Table 1.1: Bulk Material Samples (from O.Reg. 278/05)

Item Type of Material Size of Area of

Homogeneous Material

Minimum Number of Bulk

Material Samples to be

Collected

1.

Surfacing material, including without limitation material that is applied to surfaces by spraying, by trowelling or otherwise, such as acoustical plaster on ceilings and fireproofing materials on structural members

Less than 90 square metres 3

90 or more square metres, but less than 450 square

metres 5

450 or more square metres 7

2. Thermal insulation, except as described in Item 3

Any size 3

3. Thermal insulation patch Less than 2 linear metres or

0.5 square metres 1

4. Other material Any size 3

In practice, application of the Table 1 requirements means that the specified minimum number of negative

(i.e., less than 0.5% asbestos) bulk sample analysis results will be required in order to classify a material

as non asbestos.

Section 10 of O.Reg. 278/05 – Owner’s Responsibility before requesting tender or arranging work – requires

that an owner shall have an investigation carried out in order to determine if materials, that are likely to be

handled, dealt with, disturbed or removed during the alteration of a building, are asbestos-containing and,

if so, whether the asbestos-containing material is friable or non-friable and to identify the type of asbestos

in the material. Section 10 also requires that the owner shall have a report prepared detailing the

investigation findings which is to be provided to any prospective constructor.

Corrective Actions

If asbestos containing fireproofing or acoustical or thermal insulation has fallen and is being disturbed so

that exposure to the material is likely to occur, O.Reg. 278/05 requires that the owner shall cause the fallen

material to be cleaned up and, if it is readily apparent that material will continue to fall because of the

deterioration, the owner shall repair, seal, remove or permanently enclose the material.

O.Reg. 278/05 classifies the asbestos work operations into three types (Type 1, 2 and 3) and specifies

procedures to be followed in conducting asbestos abatement work.

Page 6: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

SURVEY OF ASBESTOS-CONTAINING MATERIALS

PINE GROVE PUBLIC SCHOOL

arcadis.com 2-1

2 METHODOLOGY

2.1 Survey

Site inspections were carried out by Arcadis staff in December 1999 to determine the locations of building

construction materials suspected of containing asbestos. All readily accessible areas, including spaces

above accessible suspended ceilings, were inspected throughout the facility. Site inspections were also

performed in select areas of the building in July 2013.

Additional site inspections were performed in select areas of the building in December 2019 as part of a

building renovation project. This report has been updated to include information from additional

investigations and remediation that took place in 2019.

Representative bulk samples of material were collected by Arcadis staff during the course of the site

inspection and were forwarded to EMSL Analytical Inc. and EMSL Canada Inc. (EMSL) for analysis of

asbestos content. Determination of the locations of asbestos-containing materials were made based on

results of bulk sample analysis, and on visual observations and physical characteristics of the applications

at each inspection location.

2.2 Assessment

During the survey, the condition of all friable materials is assessed. Assessment involves the evaluation of

a number of factors, including:

• asbestos content;

• physical damage;

• water damage;

• accessibility;

• adjacent activity, vibrations;

• air distribution system (air plenum); and

• friability.

Recommendations for appropriate corrective measures are based on findings of the assessment and

consist primarily of either repair or removal (and replacement) of the asbestos containing materials. No

recommended corrective actions were required at the time that this report was prepared.

Page 7: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

SURVEY OF ASBESTOS-CONTAINING MATERIALS

PINE GROVE PUBLIC SCHOOL

arcadis.com 3-1

3 SURVEY RESULTS

Arcadis reviewed reports prepared by Arcadis for the Halton District School Board entitled Survey and

Assessment of Asbestos-Containing Materials, Pine Grove Public School, Oakville Ontario dated August

2013, Pre-Renovation Designated Substances and Hazardous Materials Survey, Pine Grove Public School,

529 Fourth Line, Oakville, Ontario, dated April 30, 2017, and Pre-Renovation Designated Substances and

Hazardous Materials Survey, Pine Grove Public School, 529 Fourth Line, Oakville, Ontario dated April 11,

2019. Information and/or bulk sample analysis results obtained from these reports were utilized by Arcadis

in the preparation of this report.

On the basis of the survey work carried out, we report that friable asbestos containing materials are present

in Pine Grove Public School in the following accessible applications:

• thermal insulation applied to pipe fittings below ceilings in Rooms 1A, 23A, 33, 33A and 46;

• thermal insulation applied to pipe fittings above ceilings in Room 42A and Corridors 49, 50, 51, 53,

54 and 55;

• thermal insulation applied to pipe straights in Corridors 53, 54 and 55;

• boiler breeching insulation in Room 33; and

• vermiculite roofing material in the southeast roof.

Asbestos-containing thermal insulation applied to pipe fittings is a grey-coloured cementitious material.

Asbestos-containing thermal insulation applied to pipe straights is “Air-Cell” or “Anti-sweat” insulation.

“Aircell” is a trade name for a grey-coloured corrugated paper-like type of pipe insulation, usually found on

heating and domestic hot water piping. “Anti-sweat” insulation is a layered paper-like material, typically

brown in colour that may contain intermittent layers of black tar-like paper and/or intermittent layers of a

white paper-like material, usually found on domestic cold-water lines and sanitary and rainwater piping.

Glass fibre insulation is readily visually distinguishable (typically yellow in colour) from asbestos containing

insulation materials and was, therefore, not tested for asbestos content.

All thermal insulation, with the exception of glass fibre material, should be assumed to contain asbestos

unless a bulk sample analysis indicates otherwise.

Visual inspections and laboratory analyses of representative bulk samples of materials confirm that

non-friable asbestos-containing materials are present in the following accessible applications:

• vinyl floor tiles (assumed asbestos) throughout the facility;

• cement pipe (assumed asbestos) in pipe chases in Rooms 28 and 30A; and

• cement board (assumed asbestos) on exterior fascia throughout the building.

A room-by-room summary of the locations and conditions of asbestos-containing materials identified is

presented in Table 3.2. The locations of accessible asbestos containing materials are identified on the floor

plans provided in Appendix A.

A summary of the results of laboratory analysis of bulk samples is presented in Table 3.1. The laboratory

reports are provided in Appendix B.

Page 8: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

SURVEY OF ASBESTOS-CONTAINING MATERIALS

PINE GROVE PUBLIC SCHOOL

arcadis.com 3-2

Table 3.1: Summary of Laboratory Analyses of Bulk Samples

Pine Grove Public School

Sample No Location Description Asbestos Content

1956 Era of Construction

1A Room 41 Drywall joint compound None detected (1)

1B Room 41 Drywall joint compound None detected (1)

1C Room 41 Drywall joint compound None detected (1)

2A Room 40 Interior door caulking - white <0.25% Chrysotile (PLM) (1)

0.37% Chrysotile (TEM) (1)

2B Room 39 Interior door caulking - white <0.25% Chrysotile (1,4)

2C Room 40 Interior door caulking - white <0.25% Chrysotile (1,4)

3A Room 40 Concrete block mortar None detected (1)

3B Room 39 Concrete block mortar None detected (1)

3C Room 40 Concrete block mortar None detected (1)

4A Room 39 Ceramic block mortar None detected (1)

4B Room 40 Ceramic block mortar None detected (1)

4C Room 39 Ceramic block mortar None detected (1)

5A Room 40 Paint on concrete block None detected (1)

5B Room 39 Paint on concrete block None detected (1)

5C Room 40 Paint on concrete block None detected (1)

15A Exterior Exterior door caulking <0.25% Chrysotile (PLM) (1,4)

0.41% Chrysotile (TEM) (1,4)

15B Exterior Exterior door caulking <0.25% Chrysotile (PLM) (1,4)

15C Exterior Exterior door caulking None detected (1)

16A Exterior Exterior brick mortar None detected (1)

16B Exterior Exterior brick mortar None detected (1)

16C Exterior Exterior brick mortar None detected (1)

1957 Era of Construction

18A Room 18 Paint on concrete block None detected (1)

Page 9: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

SURVEY OF ASBESTOS-CONTAINING MATERIALS

PINE GROVE PUBLIC SCHOOL

arcadis.com 3-3

Sample No Location Description Asbestos Content

18B Room 20 Paint on concrete block None detected (1)

18C Room 21 Paint on concrete block None detected (1)

19A Room 18 Concrete block mortar None detected (1)

19B Room 19 Concrete block mortar None detected (1)

19C Corridor 55 Concrete block mortar None detected (1)

1960 Era of Construction

20A Room 22 Concrete block mortar None detected (1)

20B Room 24 Concrete block mortar None detected (1)

20C Corridor 56 Concrete block mortar None detected (1)

21A Room 22 Drywall joint compound None detected (1)

21B Room 23 Drywall joint compound None detected (1)

21C Room 23 Drywall joint compound None detected (1)

22A Room 22 Paint on concrete block None detected (1)

22B Room 23 Paint on concrete block None detected (1)

22C Room 24 Paint on concrete block None detected (1)

23A Room 24 1’x1’ wall tile – 22 holes None detected (1)

23B Room 25 1’x1’ wall tile – 22 holes None detected (1)

23C Room 24 1’x1’ wall tile – 22 holes None detected (1)

24A Corridor 56 1’x1’ ceiling tile adhesive None detected (1)

24B Corridor 56 1’x1’ ceiling tile adhesive None detected (1)

24C Corridor 56 1’x1’ ceiling tile adhesive None detected (1)

1963 Era of Construction

6A Room 4A Interior door caulking - white None detected (PLM) (1)

None detected (TEM) (1)

6B Room 2A Interior door caulking - white None detected (1)

6C Room 4A Interior door caulking - white None detected (1)

7A Room 2A Concrete block mortar <0.25% Chrysotile (Pt Ct) (1,4)

Page 10: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

SURVEY OF ASBESTOS-CONTAINING MATERIALS

PINE GROVE PUBLIC SCHOOL

arcadis.com 3-4

Sample No Location Description Asbestos Content

7B Room 4A Concrete block mortar <0.25% Chrysotile (Pt Ct) (1,4)

7C Room 2A Concrete block mortar <0.25% Chrysotile (Pt Ct) (1,4)

8A Room 2A Ceramic block mortar <0.25% Chrysotile (Pt Ct) (1,4)

8B Room 4A Ceramic block mortar <0.25% Chrysotile (Pt Ct) (1,4)

8C Room 2A Ceramic block mortar <0.25% Chrysotile (Pt Ct) (1,4)

9A Room 50 Brick mortar <0.25% Chrysotile (Pt Ct) (1,4)

9B Room 50 Brick mortar <0.25% Chrysotile (Pt Ct) (1,4)

9C Room 50 Brick mortar <0.25% Chrysotile (Pt Ct) (1,4)

10A Room 4A Ceramic tile grout <0.25% Chrysotile (Pt Ct) (1,4)

10B Room 4A Ceramic tile grout <0.25% Chrysotile (Pt Ct) (1,4)

10C Room 4A Ceramic tile grout <0.25% Chrysotile (Pt Ct) (1,4)

11A Room 4A Ceramic tile mortar bed <0.25% Chrysotile (Pt Ct) (1,4)

11B Room 4A Ceramic tile mortar bed <0.25% Chrysotile (Pt Ct) (1,4)

11C Room 4A Ceramic tile mortar bed <0.25% Chrysotile (Pt Ct) (1,4)

12A Room 2A Paint on concrete block None detected (1)

12B Room 4A Paint on concrete block None detected (1)

12C Room 2A Paint on concrete block None detected (1)

13A Exterior Exterior door caulking - grey None detected (1)

13B Exterior Exterior door caulking - grey None detected (1)

13C Exterior Exterior door caulking - grey None detected (1)

14A Exterior Exterior brick mortar None detected (1)

14B Exterior Exterior brick mortar None detected (1)

14C Exterior Exterior brick mortar None detected (1)

15A Corridor 53 2’x4’ ceiling tile – fissure on 2’ None detected (1)

15B Corridor 53 2’x4’ ceiling tile – fissure on 2’ None detected (1)

15C Corridor 53 2’x4’ ceiling tile – fissure on 2’ None detected (1)

16A Room 9 2’x4’ ceiling tile – pinhole small fissure None detected (1)

Page 11: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

SURVEY OF ASBESTOS-CONTAINING MATERIALS

PINE GROVE PUBLIC SCHOOL

arcadis.com 3-5

Sample No Location Description Asbestos Content

16B Room 22 2’x4’ ceiling tile – pinhole small fissure None detected (1)

16C Room 36 2’x4’ ceiling tile – pinhole small fissure None detected (1)

17A Room 5 2’x4’ ceiling tile – pinhole random fissure None detected (1)

17B Room 34 2’x4’ ceiling tile – pinhole random fissure None detected (1)

17C Corridor 54 2’x4’ ceiling tile – pinhole random fissure None detected (1)

25A Room 3 Drywall joint compound None detected (1)

25B Room 43 Drywall joint compound None detected (1)

25C Room 45 Drywall joint compound None detected (1)

26A Room 45 1’x1’ wall tile – small in medium holes None detected (1)

26B Room 45 1’x1’ wall tile – small in medium holes None detected (1)

26C Room 45 1’x1’ wall tile – small in medium holes None detected (1)

Unspecified era of construction

1A Room 28 2’ x 4’ Ceiling tile – Random small fissure and

pinhole None detected (2)

1B Room 28 2’ x 4’ Ceiling tile – Random small fissure and

pinhole None detected (2)

1C Room 28 2’ x 4’ Ceiling tile – Random small fissure and

pinhole None detected (2)

2A Room 30A 2’ x 4’ Ceiling tile – Random wide fissure and pinhole None detected (2)

2B Room 30A 2’ x 4’ Ceiling tile – Random wide fissure and pinhole None detected (2)

2C Room 30A 2’ x 4’ Ceiling tile – Random wide fissure and pinhole None detected (2)

3A Room 28 Concrete block mortar None detected (2)

3B Room 30A Concrete block mortar None detected (2)

3C Room 30A Concrete block mortar None detected (2)

4A Room 28 Concrete block filler paint None detected (2)

4B Room 30A Concrete block filler paint None detected (2)

4C Room 30A Concrete block filler paint None detected (2)

5A Room 30A Drywall wall joint compound None detected (2)

Page 12: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

SURVEY OF ASBESTOS-CONTAINING MATERIALS

PINE GROVE PUBLIC SCHOOL

arcadis.com 3-6

Sample No Location Description Asbestos Content

5B Room 30A Drywall wall joint compound None detected (2)

5C Room 30A Drywall wall joint compound None detected (2)

6A Room 28 Black paper inside HVAC ductwork None detected (TEM) (2)

6B Room 28 Black paper inside HVAC ductwork None detected (2)

6C Room 28 Black paper inside HVAC ductwork None detected (2)

7A Room 28 Concrete block wall expansion joint caulking – Beige

on grey None detected (2)

7B Room 29 Concrete block wall expansion joint caulking – Beige

on grey None detected (2)

7C Room 30A Concrete block wall expansion joint caulking – Beige

on grey None detected (2)

8A Room 30A Door caulking - Taupe None detected (2)

8B Room 30A Door caulking - Taupe None detected (2)

8C Room 28 Door caulking - Taupe None detected (2)

9A Room 30A 3” Red ceramic cove base tile grout - Brown None detected (2)

9B Room 30A 3” Red ceramic cove base tile grout - Brown None detected (2)

9C Room 28 3” Red ceramic cove base tile grout - Brown None detected (2)

10A Room 30A 3” Red ceramic cove base tile mortar - Grey None detected (2)

10B Room 30A 3” Red ceramic cove base tile mortar - Grey None detected (2)

10C Room 28 3” Red ceramic cove base tile mortar - Grey None detected (2)

1 Area 30A (2’ x 4’) ceiling tile None detected (3)

2 Area 24 12” ceiling tile None detected (3)

3 Area 55 Pipe straight insulation (anti-sweat) 7.3% chrysotile (TEM) (3)

4 Area 55 (2’ x 4’) ceiling tile None detected (3)

5 Area 55 Pipe fitting insulation 57% chrysotile (3)

6 Area 8 (2’ x 4’) ceiling tile None detected (3)

7 Area 3 12” ceiling tile None detected (3)

8 Area 3 Domestic hot water pipe fitting insulation 40% chrysotile (3)

Page 13: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

SURVEY OF ASBESTOS-CONTAINING MATERIALS

PINE GROVE PUBLIC SCHOOL

arcadis.com 3-7

Sample No Location Description Asbestos Content

10 Area 46 Rain drain pipe fitting insulation 36% chrysotile (3)

11 Area 33 Domestic water pipe fitting insulation 57% chrysotile (3)

12 Area 33 Boiler breeching insulation 31% chrysotile (3)

13 Area 33 Domestic water pipe straight insulation (anti-sweat) 0.27% chrysotile (3,4)

14 Area 33 Parging material on breeching None detected (3)

15 Area 33 Hot water heating pipe fitting insulation 36% chrysotile (3)

16 Area 54 Pipe straight insulation 57% chrysotile (3)

17 Area 52 (2’ x 4’) ceiling tile None detected (3)

18 Area 54 (2’ x 4’) ceiling tile None detected (3)

19 Area 34 (2’ x 4’) ceiling tile None detected (3)

20 Area 51 (2’ x 4’) ceiling tile None detected (3)

1A Southeast

roof Vermiculite Libby amphibole (5)

NOTES:

(1) Sample results derived from a report prepared by Arcadis for the Halton District School Board entitled Pre-Renovation Designated Substances and Hazardous Materials Survey, Pine Grove Public School, 529 Fourth Line, Oakville, Ontario dated April 11, 2019.

(2) Sample results derived from a report prepared by Arcadis for the Halton District School Board entitled Pre-Renovation Designated Substances and Hazardous Materials Survey, Pine Grove Public School, 529 Fourth Line, Oakville, Ontario dated April 30, 2017.

(3) Sample results derived from a report prepared by DCS (now Arcadis) for the Halton District School Board entitled Survey of Asbestos-Containing Materials, Pine Grove Public School, Oakville dated August 2013.

(4) “Asbestos-containing material” is defined as material that contains 0.5% or more asbestos by dry weight.

(5) Sample collected in August 2017.

Bulk samples were analyzed by Polarized Light Microscopy (PLM) analysis, except where “TEM” is noted, in which case Transmission Electron Microscopy analysis was also performed.

< = less than.

Chrysotile = Chrysotile asbestos. Amosite = Amosite asbestos. Libby amphibole = Libby amphibole asbestos.

Page 14: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

SURVEY OF ASBESTOS-CONTAINING MATERIALS

PINE GROVE PUBLIC SCHOOL

arcadis.com

3-8

Table 3.2: Summary of Asbestos-Containing Materials

PINE GROVE PUBLIC SCHOOL

Level Room Material Asbestos

Content

Location

Within Space

Estimated

Quantity

Friable or

Non-Friable Condition Comments

1 1 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

1 1A Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

Pipe fitting insulation 25 to 75% Chrysotile Below ceiling <5 fittings Friable G

1 2 NACMO

1 2A NACMO

1 3 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

1 4 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

1 4A NACMO

1 5 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

1 6 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

1 7 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

1 8 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

1 9 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

1 10 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

1 11 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

1 12 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

Page 15: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

SURVEY OF ASBESTOS-CONTAINING MATERIALS

PINE GROVE PUBLIC SCHOOL

arcadis.com

3-9

Level Room Material Asbestos

Content

Location

Within Space

Estimated

Quantity

Friable or

Non-Friable Condition Comments

1 13 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

1 14 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

1 15 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

1 16 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

1 17 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

1 18 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

1 19 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

1 20 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

1 21 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

1 22 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

1 23 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

1 23A Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

Pipe fitting insulation 25 to 75% Chrysotile Below ceiling <5 fittings Friable G

1 24 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

1 25 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

1 26 Vinyl floor tile Assumed asbestos All flooring >100 m2 Non-friable G

1 27 Vinyl floor tile Assumed asbestos All flooring 10-50 m2 Non-friable G

1 28 Cement pipe Assumed asbestos In pipe chase 3-10 m Non-friable G

Page 16: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

SURVEY OF ASBESTOS-CONTAINING MATERIALS

PINE GROVE PUBLIC SCHOOL

arcadis.com

3-10

Level Room Material Asbestos

Content

Location

Within Space

Estimated

Quantity

Friable or

Non-Friable Condition Comments

1 29 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

1 30 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

1 30A Cement pipe Assumed asbestos In pipe chase 3-10 m Non-friable G

1 32 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

1 33 Pipe fitting insulation 50 to 75% Chrysotile Below ceiling >20 fittings Friable G

Boiler Breeching 25 to 50% Chrysotile Below ceiling <10 m2 Friable G

1 33A Pipe fitting insulation 25 to 50% Chrysotile Below ceiling 5 fittings Friable G

1 34 NACMO

1 34A NACMO

1 34B NACMO

1 34C Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

1 35 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

1 36 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

1 37 NACMO

1 38 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

1 39 NACMO

1 40 NACMO

1 41 Vinyl floor tile Assumed asbestos All flooring 10-50 m2 Non-friable G

Page 17: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

SURVEY OF ASBESTOS-CONTAINING MATERIALS

PINE GROVE PUBLIC SCHOOL

arcadis.com

3-11

Level Room Material Asbestos

Content

Location

Within Space

Estimated

Quantity

Friable or

Non-Friable Condition Comments

1 41C Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

1 42 Vinyl floor tile Assumed asbestos All flooring 50-100 m2 Non-friable G

1 42A Vinyl floor tile Assumed asbestos All flooring 10-50 m2 Non-friable G

Pipe fitting insulation 25 to 50% Chrysotile Above ceiling 5 to 10 fittings Friable G

1 45 NACMO

1 46 Pipe fitting insulation 25 to 75% Chrysotile Below ceiling 10 to 20 fittings Friable G

1 47 NACMO

1 48 NACMO

1 49 Pipe fitting insulation 25 to 75% Chrysotile Above ceiling >20 fittings Friable G

1 50 Pipe fitting insulation 25 to 75% Chrysotile Above ceiling >20 fittings Friable G

1 51 Pipe fitting insulation 25 to 50% Chrysotile Above ceiling 10-20 fittings Friable G

1 52 NACMO

1 53 Pipe fitting insulation 50 to 75% Chrysotile Above ceiling >20 fittings Friable G

Pipe straight insulation 50 to 75% Chrysotile Above ceiling 3-10 m Friable G

1 54 Pipe fitting insulation 50 to 75% Chrysotile Above ceiling >20 fittings Friable G

Pipe straight insulation 50 to 75% Chrysotile Above ceiling 3-10 m Friable G

1 55 Pipe fitting insulation 5 to 75 % Chrysotile Above ceiling >20 fittings Friable G

Pipe straight insulation 5 to 75 % Chrysotile Above ceiling 10-30 m Friable G

Page 18: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

SURVEY OF ASBESTOS-CONTAINING MATERIALS

PINE GROVE PUBLIC SCHOOL

arcadis.com

3-12

Level Room Material Asbestos

Content

Location

Within Space

Estimated

Quantity

Friable or

Non-Friable Condition Comments

1 56 NACMO

1 57 NACMO

1 58 NACMO

1 Exterior Cement board Assumed asbestos Exterior fascia 50-100 m2 Non-friable G

Roof Roof Vermiculite Libby amphibole Southeast roof >100 m2 Friable G

NOTES: < = Less than. > = Greater than. Condition: G = Good. F = Fair. P = Poor. NACMO: No Asbestos-Containing Materials Observed.

NOTE!: Asbestos may also be present in locations that are presently inaccessible (e.g., in pipe chases, behind walls, above suspended gypsum board or plaster ceilings, and below carpets).

Page 19: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

SURVEY OF ASBESTOS-CONTAINING MATERIALS

PINE GROVE PUBLIC SCHOOL

arcadis.com

4-1

4 DISCUSSION

The owner of a building is required to provide information on the locations of asbestos containing material

to:

i) any person who is an “occupier”(1) of the building. The occupier is then responsible for

providing the information to their own employees;

ii) any prospective constructors, contractors and subcontractors prior to requesting tenders

or arranging for the demolition, alteration or repair of all or part of a building. The

information to be provided shall identify whether any material that is likely to be handled,

dealt with, disturbed or removed is asbestos-containing material; describe the condition of

the material; state whether the material is friable or non-friable; and contain drawings, plans

and specifications, as appropriate, to show the locations of material;

iii) any employer with whom the owner arranges or contracts for work not described in ii) above

that may involve asbestos-containing material or is to be carried out in close proximity to

and may disturb the material;

iv) owner’s staff, if they perform work that involves asbestos-containing material or work that

is to be carried out in close proximity to and may disturb the material.

If material suspected of containing asbestos which is not identified in the asbestos survey records is

discovered during the course of any work in a facility, then either the constructor or the owner is required

to immediately notify (orally and in writing):

a) an inspector at the office of the Ministry of Labour nearest the workplace;

b) the owner;

c) the contractor; and

d) the joint health and safety committee or the health and safety representative.

The owner is also responsible for providing tenderers with a list of designated substances (including

asbestos) at the tendering stage of a project.

This report was prepared as part of the asbestos management program, not for the purposes of construction

or renovation projects. Additional investigation and testing may be required prior to construction or

renovation projects.

Bulk sampling of building materials was carried out in accordance with the minimum sampling requirements

specified in Table 1 of O.Reg. 278/05. We recommend that additional samples of certain types of material

which may have been mixed on site at the time of construction (plaster, drywall joint compound, ceiling

(1) An “occupier” is defined as: (a) a person who is in physical possession of premises, or (b) a person who has responsibility for and control over the condition of premises or the activities carried on there, or

control over persons allowed to enter the premises.

Page 20: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

SURVEY OF ASBESTOS-CONTAINING MATERIALS

PINE GROVE PUBLIC SCHOOL

arcadis.com

4-2

texture coat, etc.) be tested for asbestos content prior to the disturbance of these materials at the time of

renovations, alterations or demolition work.

Asbestos may also be present in materials which were not sampled during the course of the asbestos

survey carried out by Arcadis, including, but not limited to, roofing materials, fire doors, mastics or

cementitious levelling compound under vinyl flooring, acoustic ceiling tile adhesive, grout, caulking, gaskets

in piping, internal components of boilers, paints and coatings, components of electrical equipment, (e.g. –

electrical wiring insulation, non-metallic sheathed cable, electrical panel partitions, arc chutes, high-grade

electrical paper, etc.), concrete, etc., and/or in locations that are presently inaccessible (e.g., in pipe chases,

behind walls, above suspended gypsum board or plaster ceilings, and below carpets). Asbestos may also

be present in the form of vermiculite insulation in cavities in concrete or cement block walls (used as in-fill

insulation). Confirmatory testing of any such materials could be undertaken as the need arises (i.e., at the

time of renovations, modifications or demolition) or the materials can be assumed to contain asbestos

based on findings in adjacent areas.

As noted above, if any materials which may contain asbestos and which were not tested during the course

of the asbestos survey are discovered during any construction activities, the work shall not proceed until

such time as the required notifications have been made and an appropriate course of action is determined.

Page 21: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

SURVEY OF ASBESTOS-CONTAINING MATERIALS

PINE GROVE PUBLIC SCHOOL

arcadis.com

5-1

5 USE AND LIMITATIONS OF THIS REPORT

This report, prepared for Halton District School Board and does not provide certification or warranty,

expressed or implied, that the investigation conducted by Arcadis identified all asbestos-containing

materials present in the subject facilities. The work undertaken by Arcadis was directed to provide

information on the presence of asbestos-containing building materials based on visual inspection of readily

accessible areas of the building and on the results of laboratory analysis of bulk samples of material

gathered in the course of the visual inspection. The survey did not include for identification of asbestos in

process materials, equipment (including electrical equipment and wiring), furniture (e.g., chairs, table tops,

chalkboards, etc.), nor material outside of the building (e.g. asphaltic pavement).

This report was prepared by Arcadis for Halton District School Board. Any use which a third party makes

of the report, or reliance on, or decisions to be based on it, is the responsibility of such third parties.

Page 22: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

APPENDIX A Floor Plans

Page 23: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

NOTES:

REVISIONS:

No. Date: By: Revisions

REFERENCE:

1.

1.

LEGEND:

FUNCTIONAL SPACE

THROUGHOUT FUNCTIONAL SPACE

ABOVE CEILING ASSEMBLY

NOTE:

REFER TO ROOM-BY-ROOM

DATA SHEETS

FOR SPECIFIC LOCATIONS OF

ASBESTOS

CEMENT PRODUCTS.

HALTON DISTRICT SCHOOL BOARD

LOCATION OF ASBESTOS CONTAINING

MATERIALS

PINE GROVE PUBLIC SCHOOL

529 FOURTH LINE, OAKVILLE, ON

BASEMENT

DEC 2019

N.T.S

G.E.C. A.N.

30038950

Drawn By:

Date:

Scale:

Approved By:

Drawing No:

Project No:

30038950-2

Page 24: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

HALTON DISTRICT SCHOOL BOARD

LOCATION OF ASBESTOS CONTAINING

MATERIALS

PINE GROVE PUBLIC SCHOOL

529 FOURTH LINE, OAKVILLE, ON

FIRST FLOOR

DEC 2019

N.T.S

G.E.C. A.N.

30038950

Drawn By:

Date:

Scale:

NOTES:

REVISIONS:

No. Date: By: Revisions

REFERENCE:

1.

1.

Approved By:

Drawing No:

Project No:

LEGEND:

FUNCTIONAL SPACE

THROUGHOUT FUNCTIONAL SPACE

ABOVE CEILING ASSEMBLY

ASBESTOS ON PIPING (FRIABLE)

ASBESTOS ON PIPE FITTINGS ONLY

(FRIABLE)

ASBESTOS ON MECHANICAL

EQUIPMENT (FRIABLE)

ASSUMED ASBESTOS FLOOR TILE

(NON-FRIABLE)

ASBESTOS CEMENT PRODUCT

30038950-1

ASBESTOS-CONTAINING VERMICULITE

IS PRESENT IN ROOFING MATERIAL.

ASSUMED ASBESTOS-CONTAINING

CEMENT BOARD ON EXTERIOR FASCIA

THROUGHOUT THE BUILDING.

Page 25: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing
Page 26: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing
Page 27: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

APPENDIX B Laboratory Reports

Page 28: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551902614

702170-193

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Attn:

Proj: Pine Grove Ps / 702170-193

Phone: (905) 882-5984

Fax: (905) 882-8962

Collected:

Received: 3/06/2019

Analyzed: 3/28/2019

Dwayne Kellyman

ARCADIS Canada Inc.

121 Granton Drive

Unit 12

Richmond Hill, ON L4B 3N4

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-00011A

Era 1956 - Room 41/Drywall Joint Compound

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-00021B

Era 1956 - Room 41/Drywall Joint Compound

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-00031C

Era 1956 - Room 41/Drywall Joint Compound

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-00042A

Era 1956 - Room 40/Interior Door Caulking - white

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/12/2019 0.0% <0.25%100% ChrysotilePLM Grav. Reduction Blue/Green

3/13/2019 0.00% 99.63% ChrysotileTEM Grav. Reduction Blue/Green 0.37%

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-00052B

Era 1956 - Room 39/Interior Door Caulking - white

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0% <1% ChrysotilePLM Green

3/28/2019 0.0% <0.25%100% ChrysotilePLM Grav. Reduction Green

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-00062C

Era 1956 - Room 40/Interior Door Caulking - white

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0% <1% ChrysotilePLM Green

3/28/2019 0.0% <0.25%100% ChrysotilePLM Grav. Reduction Green

Test Report:EPAMultiTests-7.32.2.D Printed: 3/28/2019 02:54PM Page 1 of 12

Page 29: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551902614

702170-193

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-00073A

Era 1956 - Room 40/Concrete Block Mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-00083B

Era 1956 - Room 39/Concrete Block Mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-00093C

Era 1956 - Room 40/Concrete Block Mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-00104A

Era 1956 - Room 39/Ceramic Block Mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0%PLM Gray/White Inseparable layers.None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-00114B-Mortar

Era 1956 - Room 40/Ceramic Block Mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-0011A4B-Grout

Era 1956 - Room 40/Ceramic Block Mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-00124C

Era 1956 - Room 39/Ceramic Block Mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0%PLM Gray Inseparable layers.None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-00135A

Era 1956 - Room 40/Paint on Concrete Block

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0%PLM Gray/White None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 3/28/2019 02:54PM Page 2 of 12

Page 30: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551902614

702170-193

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-00145B

Era 1956 - Room 39/Paint on Concrete Block

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0%PLM Gray/White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-00155C

Era 1956 - Room 40/Paint on Concrete Block

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-001615A

Era 1956 - Exterior/Exterior Door Caulking

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/12/2019 0.0% <0.25%100% ChrysotilePLM Grav. Reduction Blue/Green

3/13/2019 0.00% 99.59% ChrysotileTEM Grav. Reduction Blue/Green 0.41%

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-001715B

Era 1956 - Exterior/Exterior Door Caulking

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0% <1% ChrysotilePLM Gray

3/28/2019 0.0% <0.25%100% ChrysotilePLM Grav. Reduction Green

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-001815C

Era 1956 - Exterior/Exterior Door Caulking

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-001916A

Era 1956 - Exterior/Exterior Brick Mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-002016B

Era 1956 - Exterior/Exterior Brick Mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-002116C

Era 1956 - Exterior/Exterior Brick Mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0%PLM Gray None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 3/28/2019 02:54PM Page 3 of 12

Page 31: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551902614

702170-193

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-00226A

Era 1963 - Room 4A/Interior Door Caulking - white

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/12/2019 0.0% 100%PLM Grav. Reduction None DetectedWhite

3/13/2019 0.0% 100.0%TEM Grav. Reduction None DetectedWhite

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-00236B

Era 1963 - Room 2A/Interior Door Caulking - white

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-00246C

Era 1963 - Room 4A/Interior Door Caulking - white

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-00257A

Era 1963 - Room 2A/Concrete Block Mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0% <1% ChrysotilePLM Gray

3/13/2019 0.0% 100.0% <0.25% Chrysotile400 PLM Pt Ct Gray

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-00267B

Era 1963 - Room 4A/Concrete Block Mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0% <1% ChrysotilePLM Gray

3/13/2019 0.00% 99.75% 0.25% Chrysotile400 PLM Pt Ct Gray

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-00277C

Era 1963 - Room 2A/Concrete Block Mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0% <1% ChrysotilePLM Gray

3/13/2019 0.0% 100.0% <0.25% Chrysotile400 PLM Pt Ct Gray

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-00288A

Era 1963 - Room 2A/Ceramic Block Mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0% <1% ChrysotilePLM Gray

3/13/2019 0.0% 100.0% <0.25% Chrysotile400 PLM Pt Ct Gray

Test Report:EPAMultiTests-7.32.2.D Printed: 3/28/2019 02:54PM Page 4 of 12

Page 32: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551902614

702170-193

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-00298B

Era 1963 - Room 4A/Ceramic Block Mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0% <1% ChrysotilePLM Gray

3/13/2019 0.0% 100.0% <0.25% Chrysotile400 PLM Pt Ct Gray

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-00308C

Era 1963 - Room 2A/Ceramic Block Mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0% <1% ChrysotilePLM Gray

3/13/2019 0.0% 100.0% <0.25% Chrysotile400 PLM Pt Ct Gray

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-00319A

Era 1963 - Room 50/Brick Mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0% <1% ChrysotilePLM Gray

3/13/2019 0.0% 100.0% <0.25% Chrysotile400 PLM Pt Ct Gray

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-00329B

Era 1963 - Room 50/Brick Mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0% <1% ChrysotilePLM Gray

3/13/2019 0.0% 100.0% <0.25% Chrysotile400 PLM Pt Ct Gray

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-00339C

Era 1963 - Room 50/Brick Mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0% <1% ChrysotilePLM Gray

3/13/2019 0.0% 100.0% <0.25% Chrysotile400 PLM Pt Ct Gray

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-003410A

Era 1963 - Room 4A/Ceramic Tile Grout

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0% <1% ChrysotilePLM White

3/13/2019 0.0% 100.0% <0.25% Chrysotile400 PLM Pt Ct White

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-003510B

Era 1963 - Room 4A/Ceramic Tile Grout

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0% <1% ChrysotilePLM White

3/13/2019 0.0% 100.0% <0.25% Chrysotile400 PLM Pt Ct White

Test Report:EPAMultiTests-7.32.2.D Printed: 3/28/2019 02:54PM Page 5 of 12

Page 33: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551902614

702170-193

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-003610C

Era 1963 - Room 4A/Ceramic Tile Grout

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0% <1% ChrysotilePLM White

3/13/2019 0.0% 100.0% <0.25% Chrysotile400 PLM Pt Ct White

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-003711A

Era 1963 - Room 4A/Ceramic Tile Mortar Bed

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0% <1% ChrysotilePLM Gray/White

3/13/2019 0.0% 100.0% <0.25% Chrysotile400 PLM Pt Ct Gray/White

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-003811B

Era 1963 - Room 4A/Ceramic Tile Mortar Bed

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0% <1% ChrysotilePLM Gray/White

3/13/2019 0.00% 99.75% 0.25% Chrysotile400 PLM Pt Ct Gray/White

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-003911C

Era 1963 - Room 4A/Ceramic Tile Mortar Bed

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0% <1% ChrysotilePLM White

3/13/2019 0.00% 99.75% 0.25% Chrysotile400 PLM Pt Ct White

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-004012A

Era 1963 - Room 2A/Paint on concrete block

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0%PLM Gray/White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-004112B

Era 1963 - Room 2A/Paint on concrete block

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0%PLM Gray/White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-004212C

Era 1963 - Room 2A/Paint on concrete block

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0%PLM Gray/White None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 3/28/2019 02:54PM Page 6 of 12

Page 34: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551902614

702170-193

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-004313A

Era 1963 - Exterior/Exterior Door Caulking - Grey

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/12/2019 0.0% 100%PLM Grav. Reduction None DetectedGray

3/13/2019 0.0% 100.0%TEM Grav. Reduction None DetectedGray

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-004413B

Era 1963 - Exterior/Exterior Door Caulking - Grey

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-004513C

Era 1963 - Exterior/Exterior Door Caulking - Grey

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-004614A

Era 1963 - Exterior/Exterior Brick Mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-004714B

Era 1963 - Exterior/Exterior Brick Mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-004814C

Era 1963 - Exterior/Exterior Brick Mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/13/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-004915A

Corridor 53/2x4 ceiling tile - fissure on 2

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 90.0% 10.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-005015B

Corridor 53/2x4 ceiling tile - fissure on 2

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 90.0% 10.0%PLM Gray None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 3/28/2019 02:54PM Page 7 of 12

Page 35: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551902614

702170-193

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-005115C

Corridor 53/2x4 ceiling tile - fissure on 2

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 90.0% 10.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-005216A

Room 9/2x4 ceiling tile - pinhole small fissure

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 90.0% 10.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-005316B

Room 22/2x4 ceiling tile - pinhole small fissure

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 90.0% 10.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-005416C

Room 36/2x4 ceiling tile - pinhole small fissure

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 75.0% 25.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-005517A

Room 5/2x4 ceiling tile - pinhole random fissure

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 90.0% 10.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-005617B

Room 34/2x4 ceiling tile - pinhole random fissure

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 90.0% 10.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-005717C

Corridor 54/2x4 ceiling tile - pinhole random fissure

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 75.0% 25.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-005818A

Era 1957-Room 18/Paint on concrete block

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM Gray/White None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 3/28/2019 02:54PM Page 8 of 12

Page 36: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551902614

702170-193

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-005918B

Era 1957-Room 20/Paint on concrete block

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-006018C

Era 1957-Room 21/Paint on concrete block

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM Gray/White/Green Result includes a small amount of

inseparable attached materialNone Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-006119A

Era 1957-Room 18/Concrete block mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-006219B

Era 1957-Room 19/Concrete block mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-006319C

Era 1957-Corridor 55/Concrete block mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-006420A

Era 1960-Room 22/Concrete block mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-006520B

Era 1960-Room 24/Concrete block mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-006620C

Era 1960-Corridor 56/Concrete block mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM Gray None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 3/28/2019 02:54PM Page 9 of 12

Page 37: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551902614

702170-193

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-006721A

Era 1960-Room 22/Drywall Joint Compound

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-006821B

Era 1960-Room 23/Drywall Joint Compound

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-006921C

Era 1960-Room 23/Drywall Joint Compound

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM White limited sample providedNone Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-007022A

Era 1960-Room 22/Paint on concrete block

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-007122B

Era 1960-Room 23/Paint on concrete block

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-007222C

Era 1960-Room 24/Paint on concrete block

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-007323A

Era 1960-Room 24/1x1 wall tile - 22 holes

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 90.0% 10.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-007423B

Era 1960-Room 25/1x1 wall tile - 22 holes

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 90.0% 10.0%PLM Gray None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 3/28/2019 02:54PM Page 10 of 12

Page 38: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551902614

702170-193

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-007523C

Era 1960-Room 24/1x1 wall tile - 22 holes

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 75.0% 25.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-007624A

Era 1960-Corridor 56/1x1 ceiling tile adhesive

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM Brown None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-007724B

Era 1960-Corridor 56/1x1 ceiling tile adhesive

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM Brown None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-007824C

Era 1960-Corridor 56/1x1 ceiling tile adhesive

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM Brown None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-007925A

Era 1963-Room 3/Drywall Joint Compound

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-008025B

Era 1963-Room 43/Drywall Joint Compound

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-008125C

Era 1963-Room 45/Drywall Joint Compound

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-008226A

Era 1963-Room 45/1x1 wall tile - small in medium holes

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 90.0% 10.0%PLM Gray None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 3/28/2019 02:54PM Page 11 of 12

Page 39: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551902614

702170-193

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-008326B

Era 1963-Room 45/1x1 wall tile - small in medium holes

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 90.0% 10.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551902614-008426C

Era 1963-Room 45/1x1 wall tile - small in medium holes

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 80.0% 20.0%PLM Gray None Detected

Analyst(s):

PLM (16)

400 PLM Pt Ct (5)

TEM Grav. Reduction (4)

Caroline Allen

PLM (56)

400 PLM Pt Ct (10)

PLM Grav. Reduction (3)

Harman Sohi

PLM (9)

PLM Grav. Reduction (4)

Natalie D'Amico

Matthew Davis or other approved signatory

or Other Approved Signatory

Reviewed and approved by:

None Detected = <0.1%. EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported above and may

not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical

method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless

otherwise noted. This report must not be used to claim product endorsement by NVLAP of any agency of the U.S. Government.

Samples analyzed by EMSL Canada Inc. Mississauga, ON NVLAP Lab Code 200877-0Report amended: 03/25/201915:10:33 Replaces initial report from: 03/13/201917:12:44 Reason Code: Client-Samples Added

Test Report:EPAMultiTests-7.32.2.D Printed: 3/28/2019 02:54PM Page 12 of 12

Page 40: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

Sample Description TEM Result Notes

Test Report:Qualitative Asbestos Analysis by Transmission Electron Microscopy (TEM) and Filtration Technique

Attn: Ryan FarnsworthARCADIS Canada Inc.121 Granton DriveUnit 12Richmond Hill, ON L4B 3N4

Received: 08/01/17 2:43 PM

702170-114/PINEGROOVE P.S

Fax: (905) 882-8962Phone: (905) 882-5984

Project:

8/2/2017Analysis Date:Collected:

EMSL Canada Inc.2756 Slough Street, Mississauga, ON L4T 1G3Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com [email protected]

551708539CustomerID: 55DCSL97CustomerPO: 702170-114ProjectID:

EMSL Canada Or

1A551708539-0001

VERMICULITE- WHITE/BLACK COLOUR FROM SOUTH EAST ROOF

Libby Amphibole

1B551708539-0002

VERMICULITE- WHITE/BLACK COLOUR FROM SOUTH EAST ROOF

Not Analyzed

1C551708539-0003

VERMICULITE- WHITE/BLACK COLOUR FROM SOUTH EAST ROOF

Not Analyzed

Matthew Davisor other approved signatory

Test Report TEMQual-7.21.0 Printed: 8/2/2017 2:34:05 PM 1

Analyst(s)

THIS IS THE LAST PAGE OF THE REPORT.

EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported above and may not reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This is a qualitative screen only. Samples received in good condition unless otherwise noted.Samples analyzed by EMSL Canada Inc. Mississauga, ON

Natalie D'Amico (1)

Initial report from 08/02/2017 14:34:05

Page 41: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L9T 5N4

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551704130

702170-114

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Attn:

Proj: Pine Grove/702170-114

Phone: (905) 882-5984

Fax: (905) 882-8962

Collected:

Received: 4/19/2017

Analyzed: 4/22/2017

Sean Parliament

ARCADIS Canada Inc.

121 Granton Drive

Unit 12

Richmond Hill, ON L4B 3N4

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551704130-00011A

Room 28/2’ x 4’ Ceiling tile – Random small fissure and pinhole

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/22/2017 80% 20%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704130-00021B

Room 28/2’ x 4’ Ceiling tile – Random small fissure and pinhole

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/22/2017 80% 20%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704130-00031C

Room 28/2’ x 4’ Ceiling tile – Random small fissure and pinhole

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/22/2017 80% 20%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704130-00042A

Room 30A/2’ x 4’ Ceiling tile – Random wide fissure and pinhole

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/22/2017 80% 20%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704130-00052B

Room 30A/2’ x 4’ Ceiling tile – Random wide fissure and pinhole

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/22/2017 80% 20%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704130-00062C

Room 30A/2’ x 4’ Ceiling tile – Random wide fissure and pinhole

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/22/2017 80% 20%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704130-00073A

Room 28/Concrete block mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/22/2017 0% 100%PLM Gray None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 4/22/2017 01:17PM Page 1 of 5

Page 42: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L9T 5N4

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551704130

702170-114

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551704130-00083B

Room 30A/Concrete block mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/22/2017 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704130-00093C

Room 30A/Concrete block mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/22/2017 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704130-00104A

Room 28/Concrete block filler paint

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/22/2017 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704130-00114B

Room 30A/Concrete block filler paint

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/22/2017 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704130-00124C

Room 30A/Concrete block filler paint

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/22/2017 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704130-00135A

Room 30A/Drywall wall joint compound

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/22/2017 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704130-00145B

Room 30A/Drywall wall joint compound

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/22/2017 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704130-00155C

Room 30A/Drywall wall joint compound

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/22/2017 0% 100%PLM White None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 4/22/2017 01:17PM Page 2 of 5

Page 43: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L9T 5N4

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551704130

702170-114

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551704130-00166A

Room 28/Black paper inside HVAC ductwork

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/21/2017 0.0% 100%PLM Grav. Reduction None DetectedBlack

4/22/2017 0.0% 100%TEM Grav. Reduction None DetectedBlack

Client Sample ID:

Sample Description:

Lab Sample ID: 551704130-00176B

Room 28/Black paper inside HVAC ductwork

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/22/2017 70% 30%PLM Black/Yellow None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704130-00186C

Room 28/Black paper inside HVAC ductwork

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/22/2017 70% 30%PLM Black/Yellow None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704130-00197A

Room 28/Concrete block wall expansion joint caulking – Beige on grey

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/22/2017 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704130-00207B

Room 29/Concrete block wall expansion joint caulking – Beige on grey

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/22/2017 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704130-00217C

Room 30A/Concrete block wall expansion joint caulking – Beige on grey

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/22/2017 0% 100%PLM Beige None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704130-00228A

Room 30A/Door caulking - Taupe

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/22/2017 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704130-00238B

Room 30A/Door caulking - Taupe

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/22/2017 2% 98%PLM White None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 4/22/2017 01:17PM Page 3 of 5

Page 44: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L9T 5N4

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551704130

702170-114

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551704130-00248C

Room 28 /Door caulking - Taupe

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/22/2017 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704130-00259A

Room 30A/3” Red ceramic cove base tile grout - Brown

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/22/2017 0% 100%PLM Brown None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704130-00269B

Room 30A/3” Red ceramic cove base tile grout - Brown

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/22/2017 0% 100%PLM Brown None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704130-00279C

Room 28 /3” Red ceramic cove base tile grout - Brown

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/22/2017 0% 100%PLM Brown None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704130-002810A

Room 30A/3” Red ceramic cove base tile mortar - Grey

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/22/2017 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704130-002910B

Room 30A/3” Red ceramic cove base tile mortar - Grey

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/22/2017 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704130-003010C

Room 28 /3” Red ceramic cove base tile mortar - Grey

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/22/2017 0% 100%PLM Gray None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 4/22/2017 01:17PM Page 4 of 5

Page 45: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L9T 5N4

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551704130

702170-114

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Analyst(s):

PLM (20)

PLM Grav. Reduction (1)

John Biesiadecki

TEM Grav. Reduction (1)Natalie D'Amico

PLM (9)Shorthri Kalikutty

Matthew Davis

or Other Approved Signatory

Reviewed and approved by:

None Detected = <0.1%. EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported above and may

not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical

method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless

otherwise noted. This report must not be used to claim product endorsement by NVLAP of any agency of the U.S. Government.

Samples analyzed by EMSL Canada Inc. Mississauga, ON NVLAP Lab Code 200877-0Initial report from: 04/22/201713:17:19

Test Report:EPAMultiTests-7.32.2.D Printed: 4/22/2017 01:17PM Page 5 of 5

Page 46: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing
Page 47: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing
Page 48: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing
Page 49: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing
Page 50: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

APPENDIX C Sample List of Suspect Asbestos-Containing Building Materials from A Guide to the Regulation Respecting Asbestos on Construction Projects and in Buildings and Repair Operations

Page 51: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

1

APPENDIX C

SAMPLE LIST OF SUSPECT ASBESTOS-CONTAINING BUILDING MATERIALS There are an estimated 3,000 products that contain asbestos. In Ontario, asbestos was widely used in sprayed-on material and in pipe and boiler insulation until 1973(1). The use of many other asbestos-containing materials continued until the mid-1980s. Asbestos is still used in the manufacture of a limited number of products, including some floor tiles, cement products, friction materials and textiles. The following list was adapted from the United States Environmental Protection Agency’s (EPA) Sample List of Suspect Asbestos Containing Materials(2). It is not an all inclusive list but is intended as a general guide to show which types of building materials may contain asbestos.

Possible Asbestos-Containing Materials in Buildings

• Acoustical Plaster • Elevator Equipment Panels

• Adhesives • Fire Doors

• Asphalt Floor Tile • Fireproofing Materials

• Base Flashing • Flooring Backing

• Blown-in (Loose Fill) Insulation • Heating and Electrical Ducts

• Boiler Insulation • High Temperature Gaskets

• Breaching Insulation • HVAC Duct Insulation

• Caulking/Putties • Joint Compounds

• Ceiling Tiles and Lay-in Panels • Pipe Insulation (corrugated air-cell,

• Cement Pipes • block, etc.)

• Cement Siding • Roofing Felt

• Cement Wallboard • Roofing Shingles

• Construction Mastics (floor tile, • Spackling Compounds

• carpet, ceiling tile, etc.) • Sprayed-on Insulation

• Cooling Towers • Taping Compounds (thermal)

• Decorative Plaster • Textured Paper Products

• Ductwork Flexible Fabric Connections • Vinyl Floor Tile

• Electrical Cloth • Vinyl Sheet Flooring

• Electrical Wiring Insulation • Vinyl Wall Coverings

• Elevator Brake Shoes • Wallboard

(1) J.S. Dupre, J.F. Mustard & R.J. Uffin, Report of the Royal Commission on Matters of Health and Safety Arising from the Use

of Asbestos in Ontario, Ontario Ministry of the Attorney General, Toronto, Ontario, 1984, page 12. (2) U.S. Environmental Protection Agency, http://www.epa.gov/Region06/6pd/asbestos/asbmatl.htm.

Page 52: SURVEY OF ASBESTOS- CONTAINING MATERIALS · 2020-02-12 · Disposal of asbestos waste ... consist primarily of either repair or removal (and replacement) of the asbestos containing

Arcadis Canada Inc.

121 Granton Drive, Suite 12, Richmond Hill, Ontario L4B 3N4

Tel 905 882 5984

Fax 905 882 8962

www.arcadis.com