Sun Fire V880 System Architecture
Sun MicrosystemsProduct & Technology GroupSE 손종준[email protected]
Sun Fire ™ V880Enterprise RAS Below PC Pricing
" Enterprise ™ Class Application and Database Server
" Scalable Performance
ñ 8 CPUS, 32 GB memory, 12 FC- AL Disks
ñ Integrated I/0, 9 PCI Slots
" More RAS Features:
ñ Hot-Swap Fans + Power Supplies, Hot-Swap FCAL Disks, Hot-Plug PCI slots + Cards
ñ Remote System Control (RSC)
ñ Automatic System Recovery (ASR)
N E W
Product Offerings
•Entry : 2 CPUs with 4 GB System Memory
ñ2 CPUs @ 750MHz, 256K Dimms
ñ6 -36.4 GB, FC- AL Disks
ñ3(N+1 redundant) Power Supplies
ñRedundant Cooling Fan Trays
• Mid : 4 CPUs with 8 GB System Memory
ñAdditional CPU/Memory Module(4 CPUs @ 750MHz, 256K Dimms)
• High : 8 CPUs with 32 GB System Memory
ñ8 CPUs @750MHz, 512K Dimms
ñ12 -36.4 GB FC- AL Disks
Fireplane Interconnect
Hot Plug PCI
Remote System Control
RAS
UltraSPARC III
CPU/Memory Modules
FC-AL Hot Swap Disks
Memory Sub-System
Sun Fire ™ V880 System Architecture
시스템 Architecture
Su
nT
MF
ireplaneIn
tercon
nect
System
Bus -
9.6 GB
/sec.
Slo t 7
P C I
Br idge #1
B o o t
C o n t r o l
In te r face
#0
B o o t
C o n t r o l
I n t e r f a c e # 1
Boot
P R O M
S e c o n d a r y
I / O B r i d g e
33 M h z/64 b i t PCI Bus , Bus 'B'
33 M h z/64 b i t PCI Bus , Bus 'D'
66 M h z/64 b i t PCI Bus , Bus 'A'
66 M h z/64 b i t PCI Bus , Bus 'C'
S u p e r
I/OI/O
Bo
ard
Co
nn
ec
tor
Gbit
E t h e r n e t
F C - A L
D u a l
C P U / M e m o r y
B o a r d # 3
Dual
C P U / M e m o r y
B o a r d # 1
D u a l
C P U / M e m o r y
B o a r d # 4
D u a l
C P U / M e m o r y
B o a r d # 2
P C I
B r i d g e # 0
Slo t 8
S lo t
0
S C S I
C o n t r o l l e r
S lo t
1
S lo t
2
S lo t
3
S lo t
4
S lo t
5
S lo t
6
Boot Busses
Boot Busses
Serial
I/O
Ebus
Ebus
Ebus
Ebus
10/100Ethernet
USB
C P U/Memory Module" UltraSparc III CPU Modules
ñ 2 x 750MHz+ CPU's" Max of 4 modules / V880" 8 Mbytes SRAM external L2
cache memory per processor " Max of 4 G bytes of system
memory per CPUñ 16-DIMM Slots per
moduleñ 8 slots per CPU
" 32Gb maximum system memory
UltraSPARCTM III Processors•64 b i t SPARCT M Architecture running at 750 MHz. Extensible to higher speeds.
•8 MB of high-speed, secondary, external (L2) cache
•Numerous on-chip caches for enhanced performance
ñ32 Kbyte, 4-way associative instruction cache
ñ64 Kbyte, 4-way associative data cache
ñ2 Kbyte associative write cache
•Supports new pre-fetch instruction extensions to VIS, accelerates multimedia, networking, encryption, and Java processing.
Memory Subsystem•2,4 or 8-way interleaving
•8 DIM M S per CPU split as 2 memory groups of 4 D I M M s
•Currently 256- Mb or 512- Mb D I M M s
•Configuration rules:
ñD I M M s must be added in groups of 4 (no partially populated groups)
ñAl l 4 D I M M s in any group must be of identical capacity
•Memory Data Bus: 512 bits (64 Bytes) Data, 36 bit ECC
Sun Fireplane Interconnect
Su
nT
MF
ireplaneIn
tercon
nect
System
Bus -
9.6 GB
/sec.P C I
Br idge #1
B o o t
C o n t r o l
In te r face
#0
B o o t
C o n t r o l
I n t e r f a c e # 1
Boot
P R O M
I/O B
oa
rd C
on
ne
cto
r
D u a l
C P U / M e m o r y
B o a r d # 3
Dual
C P U / M e m o r y
B o a r d # 1
D u a l
C P U / M e m o r y
B o a r d # 4
D u a l
C P U / M e m o r y
B o a r d # 2
P C I
B r i d g e # 0
Boot Busses
Ebus
•System Bus is a Cross-bar switch with 6 ports:
ñOne for each of the dual processor/memory modules
ñTwo for the I/O subsystem
•One for each PCI bridge chip
•Total Aggregate Bandwidth of 9.6 GB/sec of sustained throughput
•Separate Address and Data Paths
•Superior bandwidth
ñMinimizes latency
ñReserve capacity for scalability
V880 I/O Subsytem
Su
nT
MF
ireplaneIn
tercon
nect
System
Bus -
9.6 GB
/sec.
Slo t 7
P C I
Br idge #1
B o o t
C o n t r o l
In te r face
#0
B o o t
C o n t r o l
I n t e r f a c e # 1
Boot
P R O M
S e c o n d a r y
I / O B r i d g e
33 M h z/64 b i t PCI Bus , Bus 'B'
33 M h z/64 b i t PCI Bus , Bus 'D'
66 M h z/64 b i t PCI Bus , Bus 'A'
66 M h z/64 b i t PCI Bus , Bus 'C'
S u p e r
I/O
I/O B
oard
Co
nn
ec
tor
Gbit
E t h e r n e t
F C - A L
D u a l
C P U / M e m o r y
B o a r d # 3
Dual
C P U / M e m o r y
B o a r d # 1
D u a l
C P U / M e m o r y
B o a r d # 4
D u a l
C P U / M e m o r y
B o a r d # 2
P C I
B r i d g e # 0
Slo t 8
S lo t
0
S C S I
C o n t r o l l e r
S lo t
1
S lo t
2
S lo t
3
S lo t
4
S lo t
5
S lo t
6
Boot Busses
Boot Busses
Serial
I/O
Ebus
Ebus
Ebus
Ebus
10/100Ethernet
USB
•Integrated controllers
ñTPE 10/100 Fast Ethernet
ñGigabit Ethernet (1000Base SX)
ñ2-USB Ports
ñ2-R S-232X/RS423 Serial Ports (DB25) via splitter cable
ñF C- AL Disk Controller
•9 Hot-Plug PCI 2.1 compliant slots
ñTwo 66/33Mhz slots and seven 33Mhz slots
ñ32bit or 64 bit
ñ5 volt- 33 Mhz, 3.3 volt-33/66 Mhz
ñ7 in (short) or 12 in (long) cards
ñ4 independent 64 bit PCI buses
I/O Subsystem
Steps to Hot-Plug PCI Cards
" The SunFire V880 PCI slots can support live addition & removal of PCI card's.
" This is an electrical feature that requires software support.
" The PCI card's Solaris driver must be 'Hot-Plug' aware.
" Cards can be easily added/removed by notifing Solaris in one of two ways:
ñ Using the slot control panel OR
ñ Using Solaris command(s).
" During a hot-plug operation, a 33MHz adapter cannot be connected to a 66MHz slot.
Internal Disk Subsystem•F C- AL Disk Subsytem
ñ통합 FC-AL 디스크 컨트롤러에의해 관리
ñ12 FC-AL Hot -pluggable SCA-2 Disks
ñ1.0", 10,000 RPM, 36GB
ñ두개의 분리된 backplanes에 각 6 disks 장착
ñTwo loops possible (A&B)
•Supports redundant paths to internal disks
•Volume Manager & Dynamic Multipathing
•FC-AL supports the 1.0625 Gb/sec standard, translating to 200 MB/sec fullduplex throughput.
Internal Storage Array multipath" The integrated FC- AL controller controls operations on internal
F C- AL Loop A.
" A second optional PCI FC- A L conroller can be added to provide internal FC- AL Loop B.
Qlogic 2200 onMotherboard
Expansion Backplane
Base Backplane
Sun PCI Dual-FCAL
Mu ltipathing Disks and Network" Internal/External Disk subsystem
ñ VERITAS Volume Manager 3.1.1 or later (with Dynamic Multipathing)
" External Disk subsystem
ñ StorEdge Traffic Manager
" Initial release does not provide support for FC- AL loops with boot disks
" Network – IP Network Multipathingñ Standard feature in the Solaris 8 OS
" Failure Detection
" Repair Detection
" Outbound Load Spreading
Sun StorEdge ™ T3 Array
• Rigorously tested with the Sun Fire V880 Server
• Low TCO
– Low entry point — right size at the right price
– Scalable in small increments (cost-effective growth)
• Three-way linear scalability of capacity, performance, and
availability
• Optimum SAN solution for 3-tier architecture with data sharing
Also Tested for Sun Fire V880 Server
• Sun StorEdge ™ A5200 Array
– High density, high-availability for mission-critical
environments
• Sun StorEdge ™ A1000 and D1000 Arrays
– Value -based RAID storage for workgroups and desktops
Supported Sun StorEdge Arrays
Dimensions and Weights
•Dimensions
ñHeight:
•28.1"/714mm. with casters,
•27.6"/700 mm. without casters.
•Rack tray requires 3.0"/76 mm.
•Total: 17 rack units
ñWidth 18.9"/480 mm.
ñDepth 32.9"/836 mm.
•Rackmount kit available – X9628A
•Sun StorEdge/Enterprise Expansion cabinets 지원 -2대까지 장착 가능
•Maximum AC Power consumption
ñ2240W Max
Reliability, Availability, Serviceability Features
•Reliability
ñECC Memory
ñA S R
ñEM&C System via I2 C Bus
•Availability
ñMultipathing (Disk+Network)
ñN+1 Power Supplies + Redundant FansñSolaris8 and Sun Cluster 3.0
•Serviceability
ñLEDs, Front-panel
ñHot-Plug/Hot-Swap (Disk, PSU, Fans, PCI)ñSunMC, RSC
Reliability, Availability, Serviceability Features
" Reliability - Systems ability to operate continously without failures and to maintain data integrity
ñ ECC Memory
" Error correction and parity checking
ñ ASR (Automatic System Recovery)
" Ability to recover the system in the event of a NON Fatal Error.
" Non-fatal errors detected by POST and/or OBDIAG
ñ CPU/Memory Modules (need 2)
ñ Environmental Monitoring and Control System
" PROM firmware using I2 C Bus
" Temperature sensors
Reliability, Availability, Serviceability Features
" Availability - System availability measures the percentage of time that a system is accessible by users and is providing service.
ñ Multipathing Support for Networks
ñ Hot-Swappable N+1 Power Supplies ñ Hot-Swappable Redundant Fans
ñ Support for 9-PCI Hot-Plug cardsñ Sun Cluster 3.0 support
ñ Disk RAID capabil ity" RAID 0, 1, 1+0, 5
ñ Resource Manager support to guarantee CPU availabilityñ Solaris 8
Reliability, Availability, Serviceability Features
" Serviceability - Measures the time to restore a system to operation once a failure has occurred.
ñ Easily accesible LED status indicators
ñ Front-panel LED Displayñ Hot-Plug/Hot-Swap
(Disk, PS, Fans, PCI)ñ SunMC Support
ñ Remote System Control (RSC)" Automatic notification via email
,pager, GUI, CLI
" Power on/off from remote location
" Internal environmental status monitoring
" Accessible via Modem, Serial Port, or Twisted Pair Ethernet
Remote System Control (RSC)
•Remote Administration
ñGeographically distributed or physically inaccessible systems
•Interfaces:
ñMultiplatform GUI Interface
ñCommand Line
•Remote Console
ñSerial, Ethernet , GUI, Modem
•Detailed Logs
ñRSC, Boot, Run
•Up to 4 user accounts configurable
with access control
SunFire V880: Leading Performance And Capability
" Two New World Records!
ñ Lotus Web Mail: Performance & $/Perf
ñ ECperf: Best on New Benchmark(Application World Record 8-way)
" Sun Fire V880 Consolidation Test
ñ Applications: Oracle DSS, Web, Mail
ñ Sun Solaris SRM Capabil ity N O T on Linux/ Wintel
ñ No Loss of Service Level - 100% Utilization
Sun Fire ™ V880 Current Competition
*Estimated prices for Intel boxes from Compaq, Dell, and IBM incl ude W2K operating system in the price. W2K advanced server + Internet connector Microsoft list price = $5,998 for OS
SunFire V880 vs Competition
• 가격대비 성능에서 탁월한 8-way application and database server
• Designed for future upgrades including processing speed
• Sun Fire V880 versus Windows on Intel ( Wintel):
ï - Full 64-bit architecture vs. 32-bit WinTel
ï - Up to 8 -750MHz U l t raSPARC ™ III processors that scale
ï - 4–16 times the CPU cache 8MB vs. Intel 1/2MB
ï - 6 times the system bandwidth 9.6 GB/sec. vs. 1.6 GB/sec.
ï - Mature Solaris vs. unproven Windows
SunFire V880 Value Proposition