27
Sun Fire V880 System Architecture Sun Microsystems Product & Technology Group SE 손종준 [email protected]

Sun Fire V880 System Architecture

  • Upload
    others

  • View
    13

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Sun Fire V880 System Architecture

Sun Fire V880 System Architecture

Sun MicrosystemsProduct & Technology GroupSE 손종준[email protected]

Page 2: Sun Fire V880 System Architecture

Sun Fire ™ V880Enterprise RAS Below PC Pricing

" Enterprise ™ Class Application and Database Server

" Scalable Performance

ñ 8 CPUS, 32 GB memory, 12 FC- AL Disks

ñ Integrated I/0, 9 PCI Slots

" More RAS Features:

ñ Hot-Swap Fans + Power Supplies, Hot-Swap FCAL Disks, Hot-Plug PCI slots + Cards

ñ Remote System Control (RSC)

ñ Automatic System Recovery (ASR)

N E W

Page 3: Sun Fire V880 System Architecture

Product Offerings

•Entry : 2 CPUs with 4 GB System Memory

ñ2 CPUs @ 750MHz, 256K Dimms

ñ6 -36.4 GB, FC- AL Disks

ñ3(N+1 redundant) Power Supplies

ñRedundant Cooling Fan Trays

• Mid : 4 CPUs with 8 GB System Memory

ñAdditional CPU/Memory Module(4 CPUs @ 750MHz, 256K Dimms)

• High : 8 CPUs with 32 GB System Memory

ñ8 CPUs @750MHz, 512K Dimms

ñ12 -36.4 GB FC- AL Disks

Page 4: Sun Fire V880 System Architecture

Fireplane Interconnect

Hot Plug PCI

Remote System Control

RAS

UltraSPARC III

CPU/Memory Modules

FC-AL Hot Swap Disks

Memory Sub-System

Sun Fire ™ V880 System Architecture

Page 5: Sun Fire V880 System Architecture

시스템 Architecture

Su

nT

MF

ireplaneIn

tercon

nect

System

Bus -

9.6 GB

/sec.

Slo t 7

P C I

Br idge #1

B o o t

C o n t r o l

In te r face

#0

B o o t

C o n t r o l

I n t e r f a c e # 1

Boot

P R O M

S e c o n d a r y

I / O B r i d g e

33 M h z/64 b i t PCI Bus , Bus 'B'

33 M h z/64 b i t PCI Bus , Bus 'D'

66 M h z/64 b i t PCI Bus , Bus 'A'

66 M h z/64 b i t PCI Bus , Bus 'C'

S u p e r

I/OI/O

Bo

ard

Co

nn

ec

tor

Gbit

E t h e r n e t

F C - A L

D u a l

C P U / M e m o r y

B o a r d # 3

Dual

C P U / M e m o r y

B o a r d # 1

D u a l

C P U / M e m o r y

B o a r d # 4

D u a l

C P U / M e m o r y

B o a r d # 2

P C I

B r i d g e # 0

Slo t 8

S lo t

0

S C S I

C o n t r o l l e r

S lo t

1

S lo t

2

S lo t

3

S lo t

4

S lo t

5

S lo t

6

Boot Busses

Boot Busses

Serial

I/O

Ebus

Ebus

Ebus

Ebus

10/100Ethernet

USB

Page 6: Sun Fire V880 System Architecture

C P U/Memory Module" UltraSparc III CPU Modules

ñ 2 x 750MHz+ CPU's" Max of 4 modules / V880" 8 Mbytes SRAM external L2

cache memory per processor " Max of 4 G bytes of system

memory per CPUñ 16-DIMM Slots per

moduleñ 8 slots per CPU

" 32Gb maximum system memory

Page 7: Sun Fire V880 System Architecture

UltraSPARCTM III Processors•64 b i t SPARCT M Architecture running at 750 MHz. Extensible to higher speeds.

•8 MB of high-speed, secondary, external (L2) cache

•Numerous on-chip caches for enhanced performance

ñ32 Kbyte, 4-way associative instruction cache

ñ64 Kbyte, 4-way associative data cache

ñ2 Kbyte associative write cache

•Supports new pre-fetch instruction extensions to VIS, accelerates multimedia, networking, encryption, and Java processing.

Page 8: Sun Fire V880 System Architecture

Memory Subsystem•2,4 or 8-way interleaving

•8 DIM M S per CPU split as 2 memory groups of 4 D I M M s

•Currently 256- Mb or 512- Mb D I M M s

•Configuration rules:

ñD I M M s must be added in groups of 4 (no partially populated groups)

ñAl l 4 D I M M s in any group must be of identical capacity

•Memory Data Bus: 512 bits (64 Bytes) Data, 36 bit ECC

Page 9: Sun Fire V880 System Architecture

Sun Fireplane Interconnect

Su

nT

MF

ireplaneIn

tercon

nect

System

Bus -

9.6 GB

/sec.P C I

Br idge #1

B o o t

C o n t r o l

In te r face

#0

B o o t

C o n t r o l

I n t e r f a c e # 1

Boot

P R O M

I/O B

oa

rd C

on

ne

cto

r

D u a l

C P U / M e m o r y

B o a r d # 3

Dual

C P U / M e m o r y

B o a r d # 1

D u a l

C P U / M e m o r y

B o a r d # 4

D u a l

C P U / M e m o r y

B o a r d # 2

P C I

B r i d g e # 0

Boot Busses

Ebus

•System Bus is a Cross-bar switch with 6 ports:

ñOne for each of the dual processor/memory modules

ñTwo for the I/O subsystem

•One for each PCI bridge chip

•Total Aggregate Bandwidth of 9.6 GB/sec of sustained throughput

•Separate Address and Data Paths

•Superior bandwidth

ñMinimizes latency

ñReserve capacity for scalability

Page 10: Sun Fire V880 System Architecture

V880 I/O Subsytem

Su

nT

MF

ireplaneIn

tercon

nect

System

Bus -

9.6 GB

/sec.

Slo t 7

P C I

Br idge #1

B o o t

C o n t r o l

In te r face

#0

B o o t

C o n t r o l

I n t e r f a c e # 1

Boot

P R O M

S e c o n d a r y

I / O B r i d g e

33 M h z/64 b i t PCI Bus , Bus 'B'

33 M h z/64 b i t PCI Bus , Bus 'D'

66 M h z/64 b i t PCI Bus , Bus 'A'

66 M h z/64 b i t PCI Bus , Bus 'C'

S u p e r

I/O

I/O B

oard

Co

nn

ec

tor

Gbit

E t h e r n e t

F C - A L

D u a l

C P U / M e m o r y

B o a r d # 3

Dual

C P U / M e m o r y

B o a r d # 1

D u a l

C P U / M e m o r y

B o a r d # 4

D u a l

C P U / M e m o r y

B o a r d # 2

P C I

B r i d g e # 0

Slo t 8

S lo t

0

S C S I

C o n t r o l l e r

S lo t

1

S lo t

2

S lo t

3

S lo t

4

S lo t

5

S lo t

6

Boot Busses

Boot Busses

Serial

I/O

Ebus

Ebus

Ebus

Ebus

10/100Ethernet

USB

Page 11: Sun Fire V880 System Architecture

•Integrated controllers

ñTPE 10/100 Fast Ethernet

ñGigabit Ethernet (1000Base SX)

ñ2-USB Ports

ñ2-R S-232X/RS423 Serial Ports (DB25) via splitter cable

ñF C- AL Disk Controller

•9 Hot-Plug PCI 2.1 compliant slots

ñTwo 66/33Mhz slots and seven 33Mhz slots

ñ32bit or 64 bit

ñ5 volt- 33 Mhz, 3.3 volt-33/66 Mhz

ñ7 in (short) or 12 in (long) cards

ñ4 independent 64 bit PCI buses

I/O Subsystem

Page 12: Sun Fire V880 System Architecture

Steps to Hot-Plug PCI Cards

" The SunFire V880 PCI slots can support live addition & removal of PCI card's.

" This is an electrical feature that requires software support.

" The PCI card's Solaris driver must be 'Hot-Plug' aware.

" Cards can be easily added/removed by notifing Solaris in one of two ways:

ñ Using the slot control panel OR

ñ Using Solaris command(s).

" During a hot-plug operation, a 33MHz adapter cannot be connected to a 66MHz slot.

Page 13: Sun Fire V880 System Architecture

Internal Disk Subsystem•F C- AL Disk Subsytem

ñ통합 FC-AL 디스크 컨트롤러에의해 관리

ñ12 FC-AL Hot -pluggable SCA-2 Disks

ñ1.0", 10,000 RPM, 36GB

ñ두개의 분리된 backplanes에 각 6 disks 장착

ñTwo loops possible (A&B)

•Supports redundant paths to internal disks

•Volume Manager & Dynamic Multipathing

•FC-AL supports the 1.0625 Gb/sec standard, translating to 200 MB/sec fullduplex throughput.

Page 14: Sun Fire V880 System Architecture

Internal Storage Array multipath" The integrated FC- AL controller controls operations on internal

F C- AL Loop A.

" A second optional PCI FC- A L conroller can be added to provide internal FC- AL Loop B.

Qlogic 2200 onMotherboard

Expansion Backplane

Base Backplane

Sun PCI Dual-FCAL

Page 15: Sun Fire V880 System Architecture

Mu ltipathing Disks and Network" Internal/External Disk subsystem

ñ VERITAS Volume Manager 3.1.1 or later (with Dynamic Multipathing)

" External Disk subsystem

ñ StorEdge Traffic Manager

" Initial release does not provide support for FC- AL loops with boot disks

" Network – IP Network Multipathingñ Standard feature in the Solaris 8 OS

" Failure Detection

" Repair Detection

" Outbound Load Spreading

Page 16: Sun Fire V880 System Architecture

Sun StorEdge ™ T3 Array

• Rigorously tested with the Sun Fire V880 Server

• Low TCO

– Low entry point — right size at the right price

– Scalable in small increments (cost-effective growth)

• Three-way linear scalability of capacity, performance, and

availability

• Optimum SAN solution for 3-tier architecture with data sharing

Also Tested for Sun Fire V880 Server

• Sun StorEdge ™ A5200 Array

– High density, high-availability for mission-critical

environments

• Sun StorEdge ™ A1000 and D1000 Arrays

– Value -based RAID storage for workgroups and desktops

Supported Sun StorEdge Arrays

Page 17: Sun Fire V880 System Architecture

Dimensions and Weights

•Dimensions

ñHeight:

•28.1"/714mm. with casters,

•27.6"/700 mm. without casters.

•Rack tray requires 3.0"/76 mm.

•Total: 17 rack units

ñWidth 18.9"/480 mm.

ñDepth 32.9"/836 mm.

•Rackmount kit available – X9628A

•Sun StorEdge/Enterprise Expansion cabinets 지원 -2대까지 장착 가능

•Maximum AC Power consumption

ñ2240W Max

Page 18: Sun Fire V880 System Architecture

Reliability, Availability, Serviceability Features

•Reliability

ñECC Memory

ñA S R

ñEM&C System via I2 C Bus

•Availability

ñMultipathing (Disk+Network)

ñN+1 Power Supplies + Redundant FansñSolaris8 and Sun Cluster 3.0

•Serviceability

ñLEDs, Front-panel

ñHot-Plug/Hot-Swap (Disk, PSU, Fans, PCI)ñSunMC, RSC

Page 19: Sun Fire V880 System Architecture

Reliability, Availability, Serviceability Features

" Reliability - Systems ability to operate continously without failures and to maintain data integrity

ñ ECC Memory

" Error correction and parity checking

ñ ASR (Automatic System Recovery)

" Ability to recover the system in the event of a NON Fatal Error.

" Non-fatal errors detected by POST and/or OBDIAG

ñ CPU/Memory Modules (need 2)

ñ Environmental Monitoring and Control System

" PROM firmware using I2 C Bus

" Temperature sensors

Page 20: Sun Fire V880 System Architecture

Reliability, Availability, Serviceability Features

" Availability - System availability measures the percentage of time that a system is accessible by users and is providing service.

ñ Multipathing Support for Networks

ñ Hot-Swappable N+1 Power Supplies ñ Hot-Swappable Redundant Fans

ñ Support for 9-PCI Hot-Plug cardsñ Sun Cluster 3.0 support

ñ Disk RAID capabil ity" RAID 0, 1, 1+0, 5

ñ Resource Manager support to guarantee CPU availabilityñ Solaris 8

Page 21: Sun Fire V880 System Architecture

Reliability, Availability, Serviceability Features

" Serviceability - Measures the time to restore a system to operation once a failure has occurred.

ñ Easily accesible LED status indicators

ñ Front-panel LED Displayñ Hot-Plug/Hot-Swap

(Disk, PS, Fans, PCI)ñ SunMC Support

ñ Remote System Control (RSC)" Automatic notification via email

,pager, GUI, CLI

" Power on/off from remote location

" Internal environmental status monitoring

" Accessible via Modem, Serial Port, or Twisted Pair Ethernet

Page 22: Sun Fire V880 System Architecture

Remote System Control (RSC)

•Remote Administration

ñGeographically distributed or physically inaccessible systems

•Interfaces:

ñMultiplatform GUI Interface

ñCommand Line

•Remote Console

ñSerial, Ethernet , GUI, Modem

•Detailed Logs

ñRSC, Boot, Run

•Up to 4 user accounts configurable

with access control

Page 23: Sun Fire V880 System Architecture

SunFire V880: Leading Performance And Capability

" Two New World Records!

ñ Lotus Web Mail: Performance & $/Perf

ñ ECperf: Best on New Benchmark(Application World Record 8-way)

" Sun Fire V880 Consolidation Test

ñ Applications: Oracle DSS, Web, Mail

ñ Sun Solaris SRM Capabil ity N O T on Linux/ Wintel

ñ No Loss of Service Level - 100% Utilization

Page 24: Sun Fire V880 System Architecture

Sun Fire ™ V880 Current Competition

*Estimated prices for Intel boxes from Compaq, Dell, and IBM incl ude W2K operating system in the price. W2K advanced server + Internet connector Microsoft list price = $5,998 for OS

Page 25: Sun Fire V880 System Architecture

SunFire V880 vs Competition

• 가격대비 성능에서 탁월한 8-way application and database server

• Designed for future upgrades including processing speed

• Sun Fire V880 versus Windows on Intel ( Wintel):

ï - Full 64-bit architecture vs. 32-bit WinTel

ï - Up to 8 -750MHz U l t raSPARC ™ III processors that scale

ï - 4–16 times the CPU cache 8MB vs. Intel 1/2MB

ï - 6 times the system bandwidth 9.6 GB/sec. vs. 1.6 GB/sec.

ï - Mature Solaris vs. unproven Windows

Page 26: Sun Fire V880 System Architecture

SunFire V880 Value Proposition

Page 27: Sun Fire V880 System Architecture