17
Standard detectors for particle Standard detectors for particle identification at identification at PRESPEC(2012-2013) PRESPEC(2012-2013) Plamen Boutachkov TU Darmstadt, Germany

Standard detectors for particle identification at PRESPEC ...wolle/EB_at_GSI/FRS/TALKS/AGATA...Standard detectors for particle identification at PRESPEC(2012-2013) Plamen Boutachkov

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Standard detectors for particle identification at PRESPEC ...wolle/EB_at_GSI/FRS/TALKS/AGATA...Standard detectors for particle identification at PRESPEC(2012-2013) Plamen Boutachkov

Standard detectors for particleStandard detectors for particleidentification at identification at

PRESPEC(2012-2013)PRESPEC(2012-2013)

Plamen BoutachkovTU Darmstadt, Germany

Page 2: Standard detectors for particle identification at PRESPEC ...wolle/EB_at_GSI/FRS/TALKS/AGATA...Standard detectors for particle identification at PRESPEC(2012-2013) Plamen Boutachkov

GSI projectile FRagment Separator (FRS)

Beam from SIS

TOF --> βTrajectory reconstruction --> ρ

TOF through FRS ~ 300ns L~70m

A/Q γβ = ( e/(uc) ) Bρ

∆p/p=(x4-Mx

2)/D ∆E/∆x ~ z2/β f(β)

H. Geissel et al. NIM B70 (1992) 286

Page 3: Standard detectors for particle identification at PRESPEC ...wolle/EB_at_GSI/FRS/TALKS/AGATA...Standard detectors for particle identification at PRESPEC(2012-2013) Plamen Boutachkov

S2-detectorsFinger-SCI

TPC

SCI2155

0 M

eV/u

250

MeV

/u

Page 4: Standard detectors for particle identification at PRESPEC ...wolle/EB_at_GSI/FRS/TALKS/AGATA...Standard detectors for particle identification at PRESPEC(2012-2013) Plamen Boutachkov

Time Projection Chambers(TPC)

R.Janik et al, NIM A640 (2011) 54

delay line read-out2 x-position measurements4 y-position measurements

spatial resolution: x-direction: ~ 0.18 mm y-direction: ~ 0.08 mm

Page 5: Standard detectors for particle identification at PRESPEC ...wolle/EB_at_GSI/FRS/TALKS/AGATA...Standard detectors for particle identification at PRESPEC(2012-2013) Plamen Boutachkov

TPC Efficiency

Comenius University BratislavaGSI Darmstadt

Helsinki Institute of Physics

238U ions at 1 GeV/u

Page 6: Standard detectors for particle identification at PRESPEC ...wolle/EB_at_GSI/FRS/TALKS/AGATA...Standard detectors for particle identification at PRESPEC(2012-2013) Plamen Boutachkov

Scintillators

200 mm

BC420

15 strips, 13x80x1 mm3

F. Ameil (GSI), M. Danchev(Sofia University)

Page 7: Standard detectors for particle identification at PRESPEC ...wolle/EB_at_GSI/FRS/TALKS/AGATA...Standard detectors for particle identification at PRESPEC(2012-2013) Plamen Boutachkov

Finger-Scintillators

F. Ameil, G. Guastalla(GSI)

104SnRate(S2) ~ 106 pps

ID:TPC(S2)+SCI

ε~10%

ID: Finger-SCI

ε~90%

Page 8: Standard detectors for particle identification at PRESPEC ...wolle/EB_at_GSI/FRS/TALKS/AGATA...Standard detectors for particle identification at PRESPEC(2012-2013) Plamen Boutachkov

New Finger Scintillators

60 strips, 4x80x1 mm3

The Henryk Niewodniczanski Institute of Nuclear Physics, KrakowGSI Darmstadt

Page 9: Standard detectors for particle identification at PRESPEC ...wolle/EB_at_GSI/FRS/TALKS/AGATA...Standard detectors for particle identification at PRESPEC(2012-2013) Plamen Boutachkov

S4-detectors

160

MeV

/u

SCI41MUSIC

TPC

250

MeV

/u

Page 10: Standard detectors for particle identification at PRESPEC ...wolle/EB_at_GSI/FRS/TALKS/AGATA...Standard detectors for particle identification at PRESPEC(2012-2013) Plamen Boutachkov

Multi Sampling Ionization Chamber

∆E/∆x ~ z2/β f(β)

E= 230 MeV/u E= 210 MeV/u

δE=(Π∆Εi )1 / 8 ~ z2

CF4

http://www-wnt.gsi.de/frs/technical/FRSsetup/detectors/music80/music80_manual.pdf

Page 11: Standard detectors for particle identification at PRESPEC ...wolle/EB_at_GSI/FRS/TALKS/AGATA...Standard detectors for particle identification at PRESPEC(2012-2013) Plamen Boutachkov

Pile-up

T [25 ns/ch]

Page 12: Standard detectors for particle identification at PRESPEC ...wolle/EB_at_GSI/FRS/TALKS/AGATA...Standard detectors for particle identification at PRESPEC(2012-2013) Plamen Boutachkov

50 kHz

Pile-up

S. Pietri (GSI)

Npeak

/Ntot

= 0.89

Page 13: Standard detectors for particle identification at PRESPEC ...wolle/EB_at_GSI/FRS/TALKS/AGATA...Standard detectors for particle identification at PRESPEC(2012-2013) Plamen Boutachkov

50 kHz

Pile-up compensationM. Vencelj et al. NIM A607 (2009) 581

Npeak

/Ntot

= 0.95

KVI GroningenGSI Darmstadt

Page 14: Standard detectors for particle identification at PRESPEC ...wolle/EB_at_GSI/FRS/TALKS/AGATA...Standard detectors for particle identification at PRESPEC(2012-2013) Plamen Boutachkov

Summary

Detector Max. Rate [pps]X,Y: Multi-wire chambers <104

X,Y: Current grids >108

X,Y: TPC <106

dE: MUSIC detectors <2x105

TOF: Scintillators <106

Finger Scintillator a few 106

Operation rates of FRS detectors

Page 15: Standard detectors for particle identification at PRESPEC ...wolle/EB_at_GSI/FRS/TALKS/AGATA...Standard detectors for particle identification at PRESPEC(2012-2013) Plamen Boutachkov

Tracking detector layoutTracking detector layoutPRESPEC(2012-2013)PRESPEC(2012-2013)

Page 16: Standard detectors for particle identification at PRESPEC ...wolle/EB_at_GSI/FRS/TALKS/AGATA...Standard detectors for particle identification at PRESPEC(2012-2013) Plamen Boutachkov

S2-detectorsSCI21Finger-SCI

TPC

Page 17: Standard detectors for particle identification at PRESPEC ...wolle/EB_at_GSI/FRS/TALKS/AGATA...Standard detectors for particle identification at PRESPEC(2012-2013) Plamen Boutachkov

S4-detectors PRESPEC 2012-2013

MUSIC

TPC

X,Y slits

SCI41

Degrader

LYCCATOF-Start