Click here to load reader

Solar Photovoltaic Electric System Protection Prof. … · 2016-11-16 · “Solar Photovoltaic Electric System Protection ... ( Stand alone as well as grid connected applications

  • Upload
    votu

  • View
    218

  • Download
    0

Embed Size (px)

Citation preview

  • Prof. Brian Norton

    Dr. Sarah McCormack

    Mr. Kevin OFarrell

    Solar Photovoltaic Electric System Protection

    Ayda Esfandyari

    28/02/2014

  • Overview of Project

    Introduction to Fault/Reliability Problems in PV Systems

    Specific Objective

    State of the Art

    Outline of the work

    Methodology

    Timelines

    Conclusion

    References

    Questions

  • Overview of Project

    Introduction to Fault/Reliability Problems in PV Systems

    Specific Objective

    State of the Art

    Overview of Project

    Methodology

    Time-Lines

    Conclusion

    References

    Questions

  • Overview of Project

    Global Photovoltaic (PV) capacity has been growing exponentially

    ( Stand alone as well as grid connected applications )

    Important efforts remain in terms of efficiency/performance, cost

    and reliability

    This project is part of SEAR (Solar Energy Application and

    Research)

  • PV System High-Level Components

    Balance of SystemPV Module

    PV System

    Mounting

    Structure

    Power

    Conditioning

    unit

    Protection

    /Cables

    Storage

    Protection

    Focus

  • Overview of Project

    Introduction to Fault/Reliability Problems in PV Systems

    Specific Objective

    State of the Art

    Introduction to Fault in PV

    Methodology

    Time-Lines

    Conclusion

    References

    Questions

  • Relevant Definitions

    Fault is a contingency/transient state, where system deviates from

    its nominal state. ( Fault Start Time, Fault Duration, Fault Clearing Time)

    Classical Electrical/Thermal Faults

    Short Circuit, Open Circuit, Electrical Shocks, Insulation Fault, Reverse Current,

    Overloading

    Non Classical Faults Non Classical Faults

    Arcing, Over Voltage/Surge, Shading

    Fault in PV system can be split into A.C or D.C faults

    The Protection device provides a form of insurance for electrical

    components, by blocking and reducing the duration of disturbance

  • Standards and limitations

    Different Standards, for Protection Requirements of PV Systems [1]

    I. IEC 60364-7-712:2002-05 Electrical Installations of Buildings

    II. IEC TS 62257-7-1:2006-12 Recommendations for Small Renewable Energy and Hybrid Systems for Rural Electrification

    III. IEC 62109-1&2 Safety of Power Converters for Use in Photovoltaic Power Systems

    Different Voltage Levels according to IEC [1]

    Limitations

    Considerations for electrical hazards in PV dominated by higher D.C voltage level i.e., Voltage

    levels 120v D.C

    Extra Low Voltage (ELV) level is assumed to pose low risk of threat , hence, it is generally

    exempt from protection requirements ( Loose assumption which can lead to performance

    degradation )

    IEC Voltage Range AC DC Defining Risk

    High Voltage >1000 Vrms >1500 V Electrical Arcing

    Low Voltage 50-1000 Vrms 120-1500 V Electrical Shock

    Extra-Low_voltage

  • Limitations ( continued)

    According to standard IEC NFPA 70 article 69(2014):[1]

    Hence, level of safety and careful measurements on the Low Voltage (LV) and

    Medium Voltage (MV) level for PV protection does not seem to be sophisticated

    [2] Current protection practice

  • Overview of Project

    Introduction to Fault/Reliability Problems in PV Systems

    Specific Objective

    State of the Art

    Specific Objective

    Methodology

    Time-Lines

    Conclusion

    Questions

    References

  • Objective

    The objective of this research is :

    To explore and evaluate the Necessary and Sufficient

    protection strategies that currently exist or potentially

    may prevail on Extra Low Voltage and Low Voltage

    levels.levels.

    The two conventional terms Necessary and Sufficient are used to

    distinguish between basic and satisfactory level of protections

    Note :

    Protection scheme in ELV is quite underestimated.

    Protection scheme in LV /MV is rather fragile

  • Overview of Project

    Introduction to Fault/Reliability Problems in PV Systems

    Specific Objective

    State of the Art

    State of the Art

    Methodology

    Time-Lines

    Conclusion

    References

    Questions

  • Current State of Research (Protection)

    Monitoring and fault detection for hidden faults scenarios

    [3]Zhao, Ye, et al. "Challenges to overcurrent protection devices under line-line faults in solar

    photovoltaic arrays." Energy Conversion Congress and Exposition (ECCE), 2011 IEEE. IEEE, 2011.

    [4]Zhao, Ye, et al. "LineLine Fault Analysis and Protection Challenges in Solar Photovoltaic

    Arrays." Industrial Electronics, IEEE Transactions on 60.9 (2013): 3784-3795.

    [5] Zhao, Ye, et al. "Outlier detection rules for fault detection in solar photovoltaic arrays." Applied

    Power

    [6]Xing Wu, 2011, Fault detection and diagnosis of Photovoltaic M.S. Thesis, University of Southern

    California

    [7]Silvestre, Santiago, Aissa Chouder, and Engin Karatepe. "Automatic fault detection in grid

    connected PV systems." Solar Energy 94 (2013): 119-127.

    [8]Luebke, Charles, et al. "Field test results of DC arc fault detection on residential and utility scale

    PV arrays." Photovoltaic Specialists Conference (PVSC), 2011 37th IEEE. IEEE, 2011.

  • Overview of Project

    Introduction to Fault/Reliability Problems in PV Systems

    Specific Objective

    State of the Art

    Methodology

    Methodology

    Time-Lines

    Conclusion

    References

    Questions

  • Flowchart Plan

    Comparing monitored data from experimental phase with simulation predicated results, to identify differences

    Experiment

    Prediction Isolation

    System

    Recovery

    Simulation

    Innovation/ Main

    contribution

    Analyses of

    Problem

  • Experimental Stage

    Experimental stage included number of rig experiments:

    I. Standard Steady-State Module Level ( Non Standard Test Condition )

    II. Short_Circuit Fault Module Level ( Non_STC)

    III. Open_Circuit Fault Module Level ( Non_STC)

    IV. Standard Steady-State Cell Level (Standard Test Condition )IV.

    V. Short_Circuit Fault Cell Level (STC)

    VI. Open_Circuit Fault Cell Level (STC)

    Hence, module standard conditions will be presented from cell test results

    At this phase of study, no protection element/device/agent is installed

    Choosing the fine/the most appropriate sampling time to capture Electrical

    Characteristics / measurement variables.

  • Flowchart Plan

    Experiment

    Prediction Isolation

    System

    Recovery

    Simulation

    Innovation/ Main

    contribution

    Proof of

    Analysis

  • Flowchart Plan

    Experiment

    Prediction Isolation

    System

    Recovery

    Simulation

    Innovation/ Main

    contribution

    Proof of

    Anlysis

  • Analyses

    YesNo

    Fault prediction

    Extra Small scale

    systemSmall scale system

    Examination/ fault

    occurrence validation

    Fault prediction

    Fault prediction

    Examination/ fault

    occurrence validation

    Optimal

    System

    Recovery

    Optimal

    System

    Recovery

  • Analyses

    Fault prediction

    Extra Small scale

    systemSmall scale system

    Examination/ fault

    occurrence validation

    Fault prediction

    Fault prediction

    Examination/ fault

    occurrence validation

    Optimal

    System

    Recovery

    Optimal

    System

    Recovery

  • Analyses

    YesNo

    Fault prediction

    Extra Small scale

    systemSmall scale system

    Examination/ fault

    occurrence validation

    Fault prediction

    Fault prediction

    Examination/ fault

    occurrence validation

    Optimal

    System

    Recovery

    Optimal

    System

    Recovery

  • Overview of Project

    Introduction to Fault/Reliability Problems in PV Systems

    Specific Objective

    State of the Art

    Timelines

    Methodology

    Timelines

    Conclusion

    References

    Questions

  • Timelines and Workprograms

    WP1: Literature Review/Thesis

    WP2: Estimation of Electrical Characteristics using Experimental Rigs

    WP3: Assessment of Measurement Variables by Means of Simulation

    WP4: Evaluation of System Responses, Protection Mechanism and

    Reactions

    WP5: PV System Recovery/Restoration WP5: PV System Recovery/Restoration

    Workpackages Mar(14)

    Aug(14)

    Sep(14)-

    Feb(15

    Mar(15)

    Aug(15)

    Sep(15)-

    Feb(16)

    Mar(16)

    Aug(16)

    Sep(16)-

    Feb(17)

    Mar(17)

    Aug(17)

    Sep(17)-

    Feb(18)

    Wp1 Wp1 Wp1 Wp1 Wp1 Wp1 Wp1 Wp1 Wp1

    Wp2 Wp2 Wp2

    Wp3 Wp3 Wp3

    Wp4 Wp4 Wp4

    Wp5 Wp5 Wp5 Wp5

    D D/P1 D/P2 D/P3 D/P4/P5

    M Transfer Confirmation Thesis

    Years 1 1 2 2 3 3 4 4

  • Overview of Project

    Introduction to Fault/Reliability Problems in PV Systems

    Specific Objective

    State of the Art

    Conclusion

    Methodology

    Time-Lines

    Conclusion

    References

    Questions

  • Conclusion

    ELV voltage level is treated to be inherently safe, hence, Module power is too

    low to cause serious damage ???

    There is still potential for fault /power loss and efficiency degradation in ELV (Ohmic losses ,Maximum Power Point Tracking ( MPPT),DC/AC conversion efficiencies, Operating above reference

    temperature at module level, Mismatch and non-uniform temperature and irradiance in PV generator, Fault induced lower

    irradiance )

    Scope for diagnostic analyses, to identify the accountable cause of problem

    (ELV)

    Level of safety and careful measurements on the Low Voltage (LV) level for PV

    protection does not seem to be as sophisticated

    These issues all point to room for a novel approach, to provide a

    holistic supply security and safety study on the DC side of PV systems

  • Conclusion

    Fault predication and isolation is the current focus of academic

    research and industry

    PV system restoration has the potential to be explored

    PV System Recovery Challenges

    System restoration is mostly performed on the standard High and Medium Voltage

    level systems(classical power system restoration) !!!!

    Formulation of optimal decision based problem ,which is subject

    to sets of constraint variables ( time, cost, etc)

  • Overview of Project

    Introduction to Fault/Reliability Problems in PV Systems

    Specific Objective

    State of the Art

    Conclusion

    Methodology

    Time-Lines

    Conclusion

    References

    Questions

  • References

    [1]www.iec.ch , Accessed Feb 2014

    [2] Sizing fuses for Photovoltaic Systems per the National Electrical Code, 2012, Mersen

    [3]Zhao, Ye, et al. "Challenges to overcurrent protection devices under line-line faults in solar photovoltaic arrays." Energy

    Conversion Congress and Exposition (ECCE), 2011 IEEE. IEEE, 2011.

    [4]Zhao, Ye, et al. "LineLine Fault Analysis and Protection Challenges in Solar Photovoltaic Arrays." Industrial Electronics, IEEE

    Transactions on 60.9 (2013): 3784-3795.

    [5] Zhao, Ye, et al. "Outlier detection rules for fault detection in solar photovoltaic arrays." Applied Power

    [6]Xing Wu, 2011, Fault detection and diagnosis of Photovoltaic M.S. Thesis, University of Southern California

    [7]Silvestre, Santiago, Aissa Chouder, and Engin Karatepe. "Automatic fault detection in grid connected PV systems." Solar Energy

    94 (2013): 119-127.

    [8]Luebke, Charles, et al. "Field test results of DC arc fault detection on residential and utility scale PV arrays." Photovoltaic

    Specialists Conference (PVSC), 2011 37th IEEE. IEEE, 2011.

  • Thank you