SMC Air Dryer

  • View
    217

  • Download
    1

Embed Size (px)

Text of SMC Air Dryer

  • Standard temperature air inlet [Series IDF ]IDF1E, 2E, 3E, 4E, 6E, 8E, 11E, 15E1, 22E, 37E, 55E, 75E, 120D, 150D, 190D, 240D, 370B

    High temperature air inlet [Series IDU ]IDU3E, 4E, 6E, 8E, 11E, 15E1, 22E, 37E, 55E, 75E

    Improved corrosion resistance with the stainless steel heat exchanger (IDF4E to 75E/IDU3E to 75E)

    Zero ozone depletion potential

    RefrigerantRefrigerant

    Up to %Air flowcapacityAir flowcapacity Up to %

    Increased by Reduced by

    Powerconsumptionconsumption

    Powerconsumption

    R134a (HFC)R407C (HFC)R134a (HFC)R407C (HFC)

    (SMC comparison) (SMC comparison)

    Series IDF/IDU

    Refrigerated Air Dryers

    An air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic equipment to fail.

    Protect Pneumatic Equipment from Moisture!Protect Pneumatic Equipment from Moisture!

    Effects of moisture on equipmentDecomposition of auto drain caused by rusting inside pipes

    Generation of water dropletsMalfunctioning of valves and actuators caused by dripping grease

    CAT.ES30-8F

    241-IDFIDU-CT.qxd 11.1.12 5:03 PM Page 1

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

  • Refrigerated Air Dryers Series IDF/IDU

    Compressed air contains moisture (water vapor, droplets), oil, debris and other foreign matter. Filters and mist separators can be used to remove droplets, oil, debris, and so on, but a dryer is necessary to remove water vapor.

    The Importance of Dryers

    Moisture

    Odors

    Particulates 3 m ormore in diameter (solids)

    Particulates less than3 m in diameter (solids)

    (Water vapor)(Debris)

    Compressor

    After-cooler

    Air Tank

    RefrigeratedAir Dryer Micro Mist

    SeparatorFilterMain Line

    Filter

    MistSeparator

    OdorRemoval

    Filter(Deodorization)

    RefrigeratedAir Dryer

    Imp

    uri

    ties

    in

    th

    e ai

    r

    Com

    pres

    sed

    air

    cont

    aini

    ng n

    oim

    purit

    ies

    Imp

    uri

    ties

    inco

    mp

    ress

    ed a

    ir

    Dry air

    The primary job of a dryer is

    dehumidification.

    Air containingmoistureAir containingmoistureAir containingmoisture

    Features 1

    IDFIDU-F.qxd 10.6.18 11:58 AM Page 2

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

  • For Screw Compressors (When an aftercooler is not installed, Refrigerated air dryer inlet temperature: ambient temperature +15C, Membrane air dryer inlet temperature: 25C)

    For Screw Compressors (When an aftercooler is installed, Refrigerated air dryer inlet temperature: 35C or 40C, Membrane air dryer inlet temperature: 25C)

    For Reciprocating Compressors (Aftercooler inlet: 180C or 70C, Refrigerated air dryer inlet temperature: 35C or 40C, Membrane air dryer inlet temperature: 25C)

    Shows standard combinations. The suffix numbers of the model indicate port size, power supply, etc. Refer to How to Order on pages 5, 9, 12, 15 and 18 for details on dryers and refer to SMC Best Pneumatics for other equipment.

    The symbol in the table indicates that no such equipment exists. The figures for air flow capacity corresponding to air compressor output are provided for reference only. The below table applies to the air pressure dew point 10C (at 0.7 MPa). In cases where other dew points are needed, refer to pages 3 and 4

    (Model Selection) in this catalog.

    Note 1) Air flow capacity conditions Suction condition ............................ 32C, Atmospheric pressure, Relative humidity 65%ANR conversion .............................. 20C, Atmospheric pressure, Relative humidity 65%

    Note 2) Air-cooled aftercooler Inlet air temperature ....................... 70CAmbient temperature ...................... 32C

    Water-cooled aftercooler Inlet air temperature ....................... 70C (Screw compressors), 180C (Reciprocating compressors, 70C for HAW2,7)Cooling water inlet temperature ...... 30C

    Note 3) Series lDF Inlet air temperature ....................... 35C saturation (IDF1E to 37E), 40C saturation (IDF55E to 75E, IDF120D to 240D)Ambient temperature ...................... 32C

    Note 4) Series lDU Inlet air temperature ....................... 55C saturation (lDU3E to 75E)Ambient temperature ...................... 32C

    Note 5) Series lDG Inlet air temperature ....................... 25CAmbient temperature ...................... 25C

    Quick Reference Guide to Air Preparation Equipment

    0.751.52.23.75.57.511152227375575110150220

    0.10.20.30.50.71.01.52.03.03.55.07.510.015.020.030.0

    0.100.190.290.480.670.961.441.922.883.364.87.29.614.419.228.8

    AT6C-04AT6C-04AT6C-04AT6C-04AT6C-04AT11C-06AT11C-06AT22C-14AT22C-14AT37C-14AT37C-14AT55C-20AT75C-20AT125C-30AT150C-40AT220C-40

    HAA7-06HAA7-06HAA7-06HAA7-06HAA7-06HAA7-06HAA15-10HAA15-10HAA22-14HAA37-14HAA37-14

    HAW2-04HAW2-04HAW2-04HAW7-06HAW7-06HAW7-06HAW22-14HAW22-14HAW37-14HAW37-14HAW55-20HAW75-20HAW110-30

    AFF2C-02AFF2C-02AFF2C-02AFF4C-03AFF4C-03AFF8C-04AFF8C-04AFF11C-06AFF22C-10AFF22C-10AFF37B-14AFF75AB-20AFF75AB-20AFF125A-30AFF125A-30AFF220A-40

    IDF1EIDF2EIDF3EIDF4EIDF6EIDF8E

    IDF11EIDF15E1IDF22EIDF22EIDF37EIDF55EIDF75E

    IDF120DIDF120DIDF190D

    IDF1EIDF2EIDF3EIDF4EIDF6EIDF8E

    IDF11EIDF15E1IDF15E1IDF22EIDF37EIDF55EIDF75E

    IDF120DIDF120DIDF150D

    Air compressor Main line

    Air tank Aftercooler Note 2)

    Air-cooled Water-cooled

    Sub line

    Main linefilter

    Refrigeratedair dryer Note 3)

    50 Hz 60 Hz

    Output(kW)

    Air flow capacity (m3/min) Note 1)Suction

    condition(32C)

    ANRconversion(20C)

    1.52.23.75.57.5111522375575110150220

    0.160.2450.440.721.21.82.64

    6.69.51319

    28.545

    0.150.240.420.691.151.72.53.86.39.112.518.327.443.2

    HAA7-06HAA7-06HAA7-06HAA7-06HAA15-10HAA15-10HAA15-10HAA37-14

    HAW2-04HAW2-04HAW7-06HAW7-06HAW22-14HAW22-14HAW22-14HAW37-14HAW55-20HAW75-20HAW110-30

    IDF2EIDF3EIDF4EIDF6EIDF8E

    IDF15E1IDF15E1IDF22EIDF55EIDF75E

    IDF120DIDF120DIDF190DIDF240D

    IDF2EIDF3EIDF4EIDF6EIDF8E

    IDF11EIDF15E1IDF22EIDF37EIDF55EIDF75E

    IDF120DIDF150DIDF240D

    Air compressor Main line

    Aftercooler Note 2)

    Air-cooled Water-cooled

    Sub line

    Refrigerated air dryer Note 3)

    50 Hz 60 Hz

    Output(kW)

    Air flow capacity (m3/min) Note 1)Suction

    condition(32C)

    ANRconversion(20C)

    1.52.23.75.57.5111522375575110150220

    0.160.2450.440.721.21.82.64

    6.69.51319

    28.545

    0.150.240.420.691.151.72.53.86.39.112.518.327.443.2

    IDU3EIDU3EIDU4EIDU6EIDU8E

    IDU15E1IDU15E1IDU22EIDU55EIDU75E

    IDU3EIDU3EIDU4EIDU6EIDU8E

    IDU11EIDU15E1IDU22EIDU37EIDU55EIDU75E

    Air compressorAir-cooled aftercooler integrated type Note 4)

    refrigerated air dryer50 Hz

    Sub line

    60 Hz

    Output(kW)

    Air flow capacity (m3/min) Note 1)Suction

    condition(32C)

    ANRconversion(20C)

    AM150C-02AM150C-02AM150C-02AM250C-03AM250C-03AM350C-04AM350C-04AM450C-06AM550C-10AM550C-10AM650-14AM850-20AM850-20

    Local line

    Mistseparator

    AMH150C-02AMH150C-02AMH250C-02AMH250C-03AMH350C-03AMH350C-04AMH450C-04AMH450C-06AMH550C-10AMH550C-10AMH650-14AMH850-20AMH850-20

    Micro mistseparator

    with pre-filter

    AMD150C-02AMD150C-02AMD250C-02AMD250C-03AMD350C-03AMD350C-04AMD450C-04AMD450C-06AMD550C-10AMD550C-10AMD650-14AMD850-20AMD850-20AMD910-30AMD910-30AMD1010-40

    Micro mistseparator

    AME150C-02AME150C-02AME250C-02AME250C-03AME350C-03AME350C-04AME450C-04AME450C-06AME550C-10AME550C-10AME650-14AME850-20AME850-20

    Super mistseparator

    AMF150C-02AMF150C-02AMF250C-02AMF250C-03AMF350C-03AMF350C-04AMF450C-04AMF450C-06AMF550C-10AMF550C-10AMF650-14AMF850-20AMF850-20AMF910-30AMF910-30AMF1000-40

    Odorremoval

    filterIDG10-02IDG20-02IDG30-02IDG50-03IDG75-04IDG100-04

    AM150C-02AM150C-02AM250C-03AM250C-03AM350C-04AM450C-06AM550C-10AM650-14AM850-20AM850-20

    Local line

    Mistseparator

    AMH150C-02AMH250C-03AMH250C-03AMH350C-04AMH450C-06AMH450C-06AMH550C-10AMH650-14AMH850-20AMH850-20

    Micro mistseparator

    with pre-filter

    AMD150C-02AMD250C-03AMD250C-03AMD350C-04AMD450C-06AMD450C-06AMD550C-10AMD650-14AMD850-20AMD850-20AMD910-30AMD910-30AMD1010-40

    Micro mistseparator

    AME150C-02AME250C-03AME250C-03AME350C-04AME450C-06AME450C-06AME550C-10AME650-14AME850-20AME850-20

    Super mistseparator

    AMF150C-02AMF250C-03AMF250C-03AMF350C-04AMF450C-06AMF450C-06AMF550C-10AMF650-14AMF850-20AMF850-20AMF900-30AMF900-30AMF1000-40

    Odorremoval

    filterIDG20-02IDG30-02IDG50-03IDG75-04

    AM150C-02AM150C-02AM250C-03AM250C-03AM350C-04AM450C-06AM550C-10AM650-14AM850-20AM850-20

    Local line

    Mistseparator

    AMH150C-02AMH250C-03AMH250C-03AMH350C-04AMH450C-06AMH450C-06AMH550C-10AMH650-14AMH850-20AMH850-20

    Micro mistseparator

    with pre-filter

    AMD150C-02AMD250C-03AMD250C-03AMD350C-04AMD450C-06AMD450C-06AMD550C-10AMD650-14AMD850-20AMD850-20AMD910-30AMD910-30AMD1010-40

    Micro mistseparator

    AME150C-02AME250C-03AME250C-03AME350C-04AME450C-06AME450C-06AME550C-10AME650-14AME850-20AME850-20

    Super mistseparator

    AMF150C-02AMF250C-03AMF250C-03AMF350C-04AMF450C-06AMF450C-06AMF550C-10AMF650-14AMF850-20AMF850-20AMF900-30AMF900-30AMF1000-40

    Odorremoval

    filterIDG20-02IDG30-02IDG50-03IDG75-04

    SMC Air Preparation Equipment

    Membraneair dryer

    Note 5)