Upload
vuxuyen
View
216
Download
0
Embed Size (px)
Slim 1Way Cassette
Indoor Units _ 16 172008 SAMSUNG Ceiling Air Conditioners
MR-AH01MWR-TH01
Individual Controllers
Panel
MR-BH01 PSSMAMWR-WS00
Accessories
Stylish & Compact
WIDE BLADEQUICK CONNECTION OF DRAIN PIPE
CEILING SOILINGPREVENTION
HIGH LIFT-UP DRAIN PUMP
Cassette type> > > >
Quiet OperationSamsung's new blade design drastically reduces noise levels, so you can relax in peace and quiet.
Check Valve Inside Drain PumpFaulty drainage installation or power failures can cause condensed water to flow back into the unit, causingleakage and odors. Samsung's air conditioners are equipped with a check valve built directly into the drainpump to prevent water from flowing backward.
Slim and Compact DesignSlim 1Way CassetteWant a cassette type air conditioner, but have limited space? Samsung's new Slim 1Way cassette type air conditioner is the answer.
26dB
35dB
33dB
43dB
Low
High
Fan speed Noise level
10.5kg
17kg
38% Down
4kW R410A model Weight
Only 135mm thickSamsung introduces the world's slimmest indoorair conditioner unit. Only 135mm thick, the Slim 1Way cassette air conditioner can be installedpractically anywhere.
Lighter indoor unitThe first to apply ABS cabinets into its indoorunits, Samsung has achieved the lightest unitson the market. Its slim lightweight design makesinstallation and maintenance a breeze.
135mm
WIDEWIDEWIDEWIDE HIGHHIGHHIGHHIGH QUICKQUICKQUICKQUICK
Check Valve
Ensure that there is sufficient installation space. Allow at least170mm for the installation.
NOTE
Min. 170mm
Please purchase PDF Split-Merge on www.verypdf.com to remove this watermark.
Indoor Units _ 18 192008 SAMSUNG Ceiling Air Conditioners
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current
(Min./Standard/Max.)
Piping Connection
Power Supply
Indoor Unit
Model
Panel
Fan Type
Air Flow Rate
Set
Panel
Sound Pressure Level ❊3)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling/Heating
Cooling ❊1)
Heating ❊2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unitOutdoor unit
SH026EAV1UH026EAV1Model
Notes❊1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.4) Due to ongoing improvement on products, specifications may change without prior notice.
Specification | Slim 1Way Cassette
Indoor Unit
Outdoor Unit
Cassette type> > > >
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3/min
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
980/2,600/3,500
950/3,300/4,600
245/695/1,120
210/910/1,300
3.74(A)
3.63(A)
1.6/3.3/5.2
1.4/5.3/6.4
6.35(1/4)
9.52(3/8)
1/220-240/50
SH026EAV1
PSSMA
CROSS FLOW FAN
8
970X135X410
1,164X212X478
9.9/13
1,180X25X460
1,250X126X530
3.1/4.5
30/25
DEFAULT
UH026EAV1
SINGLE BLDC
R410A
790X548X285
938X610X382
35.5/38
47
-10~43
-15~24
950
20
15
5
15
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current
(Min./Standard/Max.)
Piping Connection
Power Supply
Indoor Unit
Model
Panel
Fan Type
Air Flow Rate
Set
Panel
Sound Pressure Level ❊3)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling / Heating
Cooling ❊1)
Heating ❊2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unitOutdoor unit
SH035EAV1UH035EAV1Model
Notes❊1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.4) Due to ongoing improvement on products, specifications may change without prior notice.
Indoor Unit
Outdoor Unit
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3/min
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
980/3,500/4,100
950/4,000/4,750
250/1,140/1,420
210/1,160/1,390
3.07(B)
3.45(B)
1.6/5.3/6.6
1.4/5.5/6.8
6.35(1/4)
9.52(3/8)
1/220-240/50
SH035EAV1
PSSMA
CROSS FLOW FAN
8.5
970X135X410
1,164X212X478
9.9/13
1,180X25X460
1,250X126X530
3.1/4.5
32/27
DEFAULT
UH035EAV1
SINGLE BLDC
R410A
790X548X285
938X610X382
35.5/38
47
-10~43
-15~24
950
20
15
5
15
Please purchase PDF Split-Merge on www.verypdf.com to remove this watermark.