Slim 1Way Cassette Indoor Units _ 16 17 2008 SAMSUNG Ceiling Air Conditioners MR-AH01 MWR-TH01 Individual Controllers Panel MR-BH01 PSSMA MWR-WS00 Accessories Stylish & Compact WIDE BLADE QUICK CONNECTION OF DRAIN PIPE CEILING SOILING PREVENTION HIGH LIFT-UP DRAIN PUMP Cassette type > > > > Quiet Operation Samsung's new blade design drastically reduces noise levels, so you can relax in peace and quiet. Check Valve Inside Drain Pump Faulty drainage installation or power failures can cause condensed water to flow back into the unit, causing leakage and odors. Samsung's air conditioners are equipped with a check valve built directly into the drain pump to prevent water from flowing backward. Slim and Compact Design Slim 1Way Cassette Want a cassette type air conditioner, but have limited space? Samsung's new Slim 1Way cassette type air conditioner is the answer. 26dB 35dB 33dB 43dB Low High Fan speed Noise level 10.5kg 17kg 38% Down 4kW R410A model Weight Only 135mm thick Samsung introduces the world's slimmest indoor air conditioner unit. Only 135mm thick, the Slim 1Way cassette air conditioner can be installed practically anywhere. Lighter indoor unit The first to apply ABS cabinets into its indoor units, Samsung has achieved the lightest units on the market. Its slim lightweight design makes installation and maintenance a breeze. 135mm WIDE WIDE WIDE WIDE HIGH HIGH HIGH HIGH QUICK QUICK QUICK QUICK Check Valve Ensure that there is sufficient installation space. Allow at least 170mm for the installation. NOTE Min. 170mm Please purchase PDF Split-Merge on www.verypdf.com to remove this watermark.

Slim 1Way Cassette SAMSUNG/00... · 2008-10-10 · Slim 1Way Cassette 2008 SAMSUNGCeiling Air Conditioners Indoor Units_ 16 17 MWR-TH01 MR-AH01 Individual Controllers Panel MWR-WS00

  • Upload
    vuxuyen

  • View
    219

  • Download
    0

Embed Size (px)

Citation preview

Slim 1Way Cassette

Indoor Units _ 16 172008 SAMSUNG Ceiling Air Conditioners

MR-AH01MWR-TH01

Individual Controllers

Panel

MR-BH01 PSSMAMWR-WS00

Accessories

Stylish & Compact

WIDE BLADEQUICK CONNECTION OF DRAIN PIPE

CEILING SOILINGPREVENTION

HIGH LIFT-UP DRAIN PUMP

Cassette type> > > >

Quiet OperationSamsung's new blade design drastically reduces noise levels, so you can relax in peace and quiet.

Check Valve Inside Drain PumpFaulty drainage installation or power failures can cause condensed water to flow back into the unit, causingleakage and odors. Samsung's air conditioners are equipped with a check valve built directly into the drainpump to prevent water from flowing backward.

Slim and Compact DesignSlim 1Way CassetteWant a cassette type air conditioner, but have limited space? Samsung's new Slim 1Way cassette type air conditioner is the answer.

26dB

35dB

33dB

43dB

Low

High

Fan speed Noise level

10.5kg

17kg

38% Down

4kW R410A model Weight

Only 135mm thickSamsung introduces the world's slimmest indoorair conditioner unit. Only 135mm thick, the Slim 1Way cassette air conditioner can be installedpractically anywhere.

Lighter indoor unitThe first to apply ABS cabinets into its indoorunits, Samsung has achieved the lightest unitson the market. Its slim lightweight design makesinstallation and maintenance a breeze.

135mm

WIDEWIDEWIDEWIDE HIGHHIGHHIGHHIGH QUICKQUICKQUICKQUICK

Check Valve

Ensure that there is sufficient installation space. Allow at least170mm for the installation.

NOTE

Min. 170mm

Please purchase PDF Split-Merge on www.verypdf.com to remove this watermark.

Indoor Units _ 18 192008 SAMSUNG Ceiling Air Conditioners

Dimension (Net)

Dimension (Gross)

Weight (Net/Gross)

Dimension (Net)

Dimension (Gross)

Weight (Net/Gross)

Dimension (Net)

Dimension (Gross)

Weight (Net/Gross)

Capacity (Min./Standard/Max.)

Power Input (Min./Standard/Max.)

E.E.R

Running Current

(Min./Standard/Max.)

Piping Connection

Power Supply

Indoor Unit

Model

Panel

Fan Type

Air Flow Rate

Set

Panel

Sound Pressure Level ❊3)

Indoor Filter

Outdoor Unit

Model

Compressor

Refrigerant

Set

Sound Pressure Level

Temperature Range

Quantity of Ref.

Extension Length (total)

Extension Length (elevation)

Standard

Additional Ref.

Cooling/Heating

Cooling ❊1)

Heating ❊2)

Cooling

Heating

Cooling

Heating

Cooling

Heating

Liquid

Gas

WxHxD

WxHxD

WxHxD

WxHxD

High/Low

Type

WxHxD

WxHxD

Cooling

Heating

Indoor unitOutdoor unit

SH026EAV1UH026EAV1Model

Notes❊1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m❊2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m❊3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.4) Due to ongoing improvement on products, specifications may change without prior notice.

Specification | Slim 1Way Cassette

Indoor Unit

Outdoor Unit

Cassette type> > > >

Watts

Watts

Watts

Watts

W/W

W/W

Amps

Amps

mm (inch)

mm (inch)

Ø/V/Hz

m3/min

mm

mm

kg

mm

mm

kg

dB(A)

mm

mm

kg

dB(A)

°C

°C

g

m

m

m

g/m

980/2,600/3,500

950/3,300/4,600

245/695/1,120

210/910/1,300

3.74(A)

3.63(A)

1.6/3.3/5.2

1.4/5.3/6.4

6.35(1/4)

9.52(3/8)

1/220-240/50

SH026EAV1

PSSMA

CROSS FLOW FAN

8

970X135X410

1,164X212X478

9.9/13

1,180X25X460

1,250X126X530

3.1/4.5

30/25

DEFAULT

UH026EAV1

SINGLE BLDC

R410A

790X548X285

938X610X382

35.5/38

47

-10~43

-15~24

950

20

15

5

15

Dimension (Net)

Dimension (Gross)

Weight (Net/Gross)

Dimension (Net)

Dimension (Gross)

Weight (Net/Gross)

Dimension (Net)

Dimension (Gross)

Weight (Net/Gross)

Capacity (Min./Standard/Max.)

Power Input (Min./Standard/Max.)

E.E.R

Running Current

(Min./Standard/Max.)

Piping Connection

Power Supply

Indoor Unit

Model

Panel

Fan Type

Air Flow Rate

Set

Panel

Sound Pressure Level ❊3)

Indoor Filter

Outdoor Unit

Model

Compressor

Refrigerant

Set

Sound Pressure Level

Temperature Range

Quantity of Ref.

Extension Length (total)

Extension Length (elevation)

Standard

Additional Ref.

Cooling / Heating

Cooling ❊1)

Heating ❊2)

Cooling

Heating

Cooling

Heating

Cooling

Heating

Liquid

Gas

WxHxD

WxHxD

WxHxD

WxHxD

High/Low

Type

WxHxD

WxHxD

Cooling

Heating

Indoor unitOutdoor unit

SH035EAV1UH035EAV1Model

Notes❊1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m❊2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m❊3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.4) Due to ongoing improvement on products, specifications may change without prior notice.

Indoor Unit

Outdoor Unit

Watts

Watts

Watts

Watts

W/W

W/W

Amps

Amps

mm (inch)

mm (inch)

Ø/V/Hz

m3/min

mm

mm

kg

mm

mm

kg

dB(A)

mm

mm

kg

dB(A)

°C

°C

g

m

m

m

g/m

980/3,500/4,100

950/4,000/4,750

250/1,140/1,420

210/1,160/1,390

3.07(B)

3.45(B)

1.6/5.3/6.6

1.4/5.5/6.8

6.35(1/4)

9.52(3/8)

1/220-240/50

SH035EAV1

PSSMA

CROSS FLOW FAN

8.5

970X135X410

1,164X212X478

9.9/13

1,180X25X460

1,250X126X530

3.1/4.5

32/27

DEFAULT

UH035EAV1

SINGLE BLDC

R410A

790X548X285

938X610X382

35.5/38

47

-10~43

-15~24

950

20

15

5

15

Please purchase PDF Split-Merge on www.verypdf.com to remove this watermark.