Upload
truongcong
View
223
Download
0
Embed Size (px)
Citation preview
3
INFO
RMATIVE BRO
CHURE
PREMISE. Perimeter intrusion detection systems ...................................................... 5
1. SERIR 50 system ..............................................................................................7
1.1 The components of the system ............................................................................ 81.1 1 The sensors ..................................................................................................... 81.1.2 The connection cables ................................................................................... 101.1.3 The processing boards ................................................................................... 10
1.2 How to design a SERIR 50 system ....................................................................... 121.2.1 Zoning ............................................................................................................ 121.2.2 Installation of the system .............................................................................. 131.2.3 Placement of the processing boards ............................................................. 141.2.4 Contents of a field cabinet ............................................................................ 14
2. DEA NET centralization system .....................................................................17
2.1 The components of the system ............................................................................ 182.1.1 The network controllers ................................................................................. 182.1.2 DN HT REPEATER network node ................................................................... 182.1.3 Expansion and interface boards .................................................................... 19
2.1.3.1 ER16 relay expansion board (SC-DN-ER16 part no) .............................. 192.1.3.2 DN I/O interface board (SC-DN-IO part no) ........................................ 192.1.3.3 DN MANAGER interface board (SC-DN-MNG part no) ....................... 19
2.1.4 DN DEA POWER power supply unit (AL-DN-DEAPW part no) ...................... 192.1.5 The connection cable ..................................................................................... 202.1.6 The software .................................................................................................. 20
2.1.6.1 DEA MAP DLL software library (SW-DM-DLL part no) ........................ 202.1.6.2 ETHERNET SHARER centralization software (SW-ETHSHR part no) .... 20
2.2 Centralization schemes ....................................................................................... 202.2.1 Centralization with DN CONTROLLER ........................................................... 202.2.2Centralization with DN ETHERNET CONTROLLER ......................................... 21
3. DEA MAP security management software ...................................................23
3.1 Le caratteristiche principali.................................................................................. 243.1.1 The graphical map .......................................................................................... 243.1.2 The management of the detection systems ................................................... 243.1.3 Alarm handling ............................................................................................... 243.1.4 CCTV system management ............................................................................ 24
3.2 DEA MAP software versions ............................................................................... 25
4. Applicatory examples ....................................................................................27
4.1 The elements of the system ................................................................................. 284.2 Example of protection ......................................................................................... 30
5. Technical features ..........................................................................................33
6. Photo Gallery ..................................................................................................47
Contents
SERIR
50
INFO
RMAT
IVE
BRO
CHUR
E
4SERIR
TORSUS
SISMA CP 50
SISMA CA
SISMA CA PF
SERIE A03 e SPC/SPRXENSITY
SERIR
50
INFO
RMATIVE BRO
CHURE
5
PERIMETER INTRUSION DETECTION SYSTEMS
Perimeter intrusion detection systems are conceived to detect unauthorized access long before an intruder has entered the protected area. The advantage is twofold: on the one hand, these systems represent an important deterrent factor, discouraging the majority of intrusion attempts in the bud; on the other hand, they give more time to undertake the necessary defensive actions.
Protecting the perimeter of a property requires prompt, accurate and reliable detection systems. To achieve this aim, DEA Security has designed sophisticated and innovative intrusion detection technologies, which are patented at international level.
DEA Security’s R&D activity has always been focused on designing high-quality intrusion detection systems for the protection of perimeters of any size in military, industrial, commercial and residential projects.
This commitment together with the extensive experience in the outdoor security market have led to the creation of a wide range of products with high-level performance and reliability::
� SERIR, perimeter intrusion detection system for soft metal fences and semi-rigid panels;
� TORSUS, perimeter intrusion detection system for rigid metal fences; � SISMA CP 50, buried intrusion detection system; � SISMA CA, intrusion detection system for concrete flooring; � SISMA CA PF, intrusion detection system for raised floors; � DEA NET, centralization system; � DEA MAP, security management system.
DEA Security has also designed a complete range of sensors for the protection of doors, windows, gratings, glazed doors/windows, walls and safes:
� SERIE A03, seismic sensors and relevant processing boards; � SERIE SPC/SPR, seismic sensors with built-in analysis units. � XENSITY, point ID detection system.
Premise
SERIR
50
INFO
RMATIVE BRO
CHURE
Chapter
SERIR 50
7
SERIR 50SYSTEM01
SERIR 50 is a perimeter intrusion detection system for the protection of metal fences. It is suitable for any kind of perimeter in terms of dimensions and complexity, in residential, industrial and military sectors.
It consists of special piezodynamic detectors and sophisticated signal processing boards, which detect any attempt to cut, breakthrough and climb chain link or welded mesh fences and many types of semi-rigid panels. A special application of SERIR 50 system is the protection of fences or walls with concertina topping.
Operating on the boundary, SERIR offers a round-the-clock protection enabling the people inside the property to move freely.
The alarm zones of SERIR 50 system, which are up to 50 metres long, allow you to accurately identify the section of perimeter concerned by the intrusion, and can be easily coupled with videosurveillance systems (CCTV).
8
THE
SYST
EMSERIR
50 THE COMPONENTS OF THE SYSTEMS1.1
SERIR 50 system is composed of sensors, electronic boards, cables and other components produced by DEA Security according to strict quality standards. The most important components of SERIR 50 are the sensors and the processing boards, which are the result of a long process of research and development and benefit from a continuous technological upgrading.
1.1.1 I THE SENSORSSERIR 50 uses passive piezodynamic sensors which perceive the vibrations of the metal fence during an intrusion attempt for cut, climb or breakthrough. The exclusive piezodynamic technology combines a piezoceramic transducer with an inertial mass: the former raises weak electric pulses when subjected to vibrations, the latter mechanically amplifies the effect of such vibrations and therefore increases the detector sensitivity.
Specifically designed for external use, SERIR 50 sensors have high resistance towards atmospheric events to which a fence is typically exposed. Their sensitive element is sealed with epoxy and protected by a housing resisting UV rays and temperatures varying from -40° to +80° C.
These sensors are not subjected to electric failure since they do not contain active electronic components. In addition, they are not disturbed by electromagnetic fields.
Thanks to its sophisticated sensor technology, the system highly tolerates adverse weather conditions (rain, wind, snow and extreme changes in temperature) and other disturbing sources near the fence such as roads, highways, railways and machines in operation.
The tolerance towards environmental disturbances is so high that these sensors can be even installed on fences covered with climbing vegetation.
Independent detectorsSERIR 50 sensors operate independently from one another, therefore the damage or tamper (if any) of one of them does not compromise the functioning of the rest of the sensors along the string.
9
THE SYSTEM
SERIR
50
The sensors are supplied in prewired strings of 50-metre standard length. A string can be composed of 16, 20 or 25 sensors depending on the spacing between the fence posts which can be respectively of 3 metres, 2.5 metres and 2 metres. DEA can also supply sensor-strings with customized length (less than 50 metres).
The flexibility of the prewired sensor-strings allows you to fit SERIR 50 system to the conformation of the ground and the route of the perimeter, making it possible to follow bends and differences in level, avoid obstacles and overcome possible interruptions of the fence. In case a sensor or its connection cable are subjected to intentional or accidental damage, the full functionality of the system can be quickly recovered by performing a simple electric junction.
Two models of sensors are available: SN-SR50, with ABS housing, and SN-SR50-P, with polyamide housing. The latter material is highly resistant to extreme temperatures, abrasion and direct contact with crude oil and petroleum products.The ABS sensor is also available in the SN-SR50-GM variant, with connection cable protected by a metal sheath.
The prewired sensor-strings of 50-metre length are available on our catalogue under part number starting with LN-SR50. If sensor-strings with customized lengths are needed (less than 50 metres), the part number to be used is the one of the single sensor which starts with SN-SR50. E.g.: to receive a SERIR 50 prewired sensor-string composed of 10 green ABS sensors, with 2.5-metre spacing, no. 10 SN-SR50-250V sensors must be ordered.The following table shows the part numbers of the standard sensor-strings and the ones of the single sensors.
prewired sensor-strings
SENSORI NO. SPACING COLOURPART NO.50-metre standard length
252016
2 metres2,5 metres3 metres
BLACKNERONERO
LN25-SR50-P200NLN20-SR50-P250NLN16-SR50-P300N
252016
2 metres2,5 metres3 metres
GREENGREENGREEN
LN25-SR50-200VLN20-SR50-250VLN16-SR50-300V
252016
2 metres2,5 metres3 metres
GREYGREYGREY
LN25-SR50-200GLN20-SR50-250GLN16-SR50-300G
PART NO. SPACING COLOURcustomized length
SN-SR50-P200NSN-SR50-P250NSN-SR50-P300N
2 metres2,5 metres3 metres
BLACKBLACKBLACK
SN-SR50-GM200SN-SR50-GM250SN-SR50-GM300
2 metres2,5 metres3 metres
GREYGREYGREY
SN-SR50-200VSN-SR50-250VSN-SR50-300V
2 metres2,5 metres3 metres
GREENGREENGREEN
SN-SR50-200GSN-SR50-250GSN-SR50-300G
2 metres2,5 metres3 metres
GREYGREYGREY
2,5 metri
Example of installation of the sensor on a fence with post-to-post spacing of 2m, 2.5m or 3m
Example of installation of the sensor on a fence with post-to-post spacing longer than 3m
10
THE
SYST
EMSERIR
50
1.1.3 THE PROCESSING BOARDSThe signals coming from the sensor-strings are amplified and processed by SC-SR50-Z1 and SC-SR50-Z4 microprocessing boards, which analyse and interpret what is perceived by the detectors. The former manages one sensor-string (alarm zone), while the latter up to four sensor-strings.
tinned copper wires
polyolefin insulation
polyester foil
polyester/aluminium foil screen
tinned copper braid
inner jacket: flame retardant PVC compound
jacket: PVC compound, UV resistant
tinned copper wires
polyolefin insulation
polyester foil
polyester/aluminium foil screen
tinned copper braid
inner jacket: flame retardant PVC compound
jacket: polyurethane mat resistant to oil, abrasion, hydrocarbon and UV
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
Sensor-string (50m maximum)
Max distance 150 m
SC-SR50-Z1 boardmanaging
1 sensor-string
Sensor-string 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2
Sensor-string 3SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2
Sensor-string 4SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2
Sensor-string 1SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2SERIR
A - 03 ASR - 2
SC-SR50-Z4board managing 4 sensor-strings
1.1.2 THE CONNECTION CABLESSERIR 50 sensors are interconnected by means of special connection cables, CV-ST50 and CV-ST50-P, specifically designed by DEA Security for external use.
To make these cables more resistant to oxydation and to electromagnetic fields, all wire is tinned and twisted, the shielding is double and made up of an aluminium/polyester tape combined with a tinned copper braid.
As far as CV-ST50 cable is concerned, its mechanical protection and insulation are guaranteed by a double jacket, PVC based and UV resistant, and by a special polyolefin compound for each wire.
CV-ST50-P cable, to be used with SN-SR50-P sensors, is made of a polyurethane jacket which makes it more resistantto UV rays, abrasion and direct contact with crude oil and petroleum products.
11
THE SYSTEM
SERIR
50
The processing boards allow you to adjust the sensitivity parameters of the sensor-strings, so as to optimize the performance of the system in each single installation or to calibrate it according to specific needs.
The advanced detection algorithms of SERIR processing boards enable the system to discriminate the different types of intrusion, filtering all the disturbing factors which might cause improper alarms.
The calibration and programming of the processing boards are performed via PC through a user-friendly service software which displays a real time graph of the signals coming from the sensors as well as all the inputs and the outputs status.By this software you can also upload a configuration previously saved and view the event logs, where all the signals coming from the sensor-strings are recorded in chronological order. This memory allows DEA Security’s engineers to perform an accurate analysis of those events to determine the cause of the alarm.
The processing boards provide alarm, tamper and failure through relays (C/CN contacts), but can be also connected to DEA NET centralization network or to Ethernet network with IP Protocol. For details, see chapter Centralization of the signals.
Service software
Sporadic cutsSERIR processing boards have a specific function which allows you to recognize the so-called “sporadic cuts”, such as the attacks against the fence performed with single actions over time. This type of intrusion is the most insidious one, since it aims at making a hole on the fence by gradually cutting it over time.
12
THE
SYST
EMSERIR
50
chain link fence welded fence in rolls welded panel
1.2.1 ZONING
When protecting a perimeter with SERIR 50 system, few elements must be taken into account. First of all, each sensor-string must be 50 metres long maximum. In addition, along a perimeter different types of fences can be found in terms of size, shape and materials. These features may determine a different response of the sensor to the stress caused by an intrusion attempt.
Zone 1 - 50 m
Zone 2 - 50 m
Therefore it is very important to divide the perimeter so that each string can protect a section of fence having the same features: the sensitivity of each sensor-string will be calibrated according to the features of the fence to be protected.
HOW TO DESIGN A SERIR 50 SYSTEM1.2
13
THE SYSTEM
SERIR
50
1.2.2 INSTALLATION OF THE SYSTEMFor a correct installation of the system, just few simple precautions must be taken. The sensors can be installed on different types of fence, even pre-existent, provided that they are in good condition and solidly anchored. When a new fence has to be erected, we suggest using a welded mesh fence provided in rolls with 2.5 m height, 50x50 mm mesh dimensions, and a wire diameter of not less than 3 mm. These features guarantee the best transmission of the vibrations, maximizing the system performance.
Fig. 1
Fig. 2 Fig. 3
The installation of the sensor is performed by fixing each them to the fence using the screw bolts and the mounting plates provided with it (Fig. 1). A special cap covers the head of the screw bolt (Fig. 2).The cable is directly fixed to the fence through the FPM-100 tie-wraps (Fig. 3).
JTBX-ST50junction/termination case
RP100two-component polyurethane
resin
The electric connections must be tin soldered and sealed with two-component polyurethane resin RP-100 inside JTBX-ST50 cases. One pack of RP-100 seals two JTBX-ST50 cases.
14
THE
SYST
EMSERIR
50 1.2.3 POSIZIONAMENTO DELLE SCHEDE DI ELABORAZIONE
The processing boards are usually provided inside polyester cabinets (AP-C) which DEA Security assembles according to the specifications of the project. These cabinets have IP44/IK10 protection rating and are supplied with safety locks, base plate, fixing brackets, tamper switch, burglary-proof shock sensor, DIN rail terminal board, socket with thermal magnetic circuit breaker and wiring documentation. On request, DEA can also provide electronic boards in bulk: in this case we recommend the installation of the boards in suitable cabinets having features similar to the above-mentioned ones.
If the control panel is placed within 150 metres from the beginning of the sensor-string, the processing boards can beinstalled inside a cabinet placed near the control panel. If the distance between the processing boards and the sensor-string is more than 150 metres, the boards must be installed inside a field cabinet near the fence.
On DEA's offers, the cabinets are called “boxes”. The centralization cabinet, containing the Network Controller is always called “box0”.
Example of SERIR 50 system with field cabinets (box1, box2, box3) and centralization cabinet (box0)
Controlpanel
box0SC-DN-CTRL
SC-DN-ER16
box1SC-SR50-Z4
Sensors-string 1Input 1
Sensors-string 8Input 4
Sensors-string 9
Input 1
Sensors-string 10
Input 2
Sensors-string 2Input 2
Linea-sensori 3Input 3
box2SC-SR50-Z4
box3SC-SR50-Z4SC-SR50-Z1SC-DN-IO
Sens
ors-
strin
g 4
Inpu
t 4Se
nsor
s-st
ring
5In
put 1
Sensors-string 6
Input 2
Sensors-string 7
Input 3
Sensors-string 11
Input 3
Gate Sensors-string13Input 4
Sensors-string 12
Input 4
signal cables (CV-ST50/CV-ST50-P)
string-sensors SERIR 50 standard security cable
DEA NET cable
A field cabinet may contain the following devices:
� the processing boards SC-SR50-Z1 and/or SC-SR50-Z4; � the interconnection board SC-DN-HTRPT or the controller with TCP/IP protocol SC-DN-ETHCTRL;
alternatively, a third-party alarm concentrator; � a 13.8 V stabilized linear power supply unit AL-DN-DEAPW for the connection to the mains; � one or more input/output boards SC-DN-IO to send the signals from third-party devices over DEA NET; � a tamper switch; � a burglary-proof shock sensor; � a 12 V backup battery (not supplied).
1.2.4 COMPOSIZIONE DI UN ARMADIO PERIFERICO
15
THE SYSTEM
SERIR
50
Typical configuration of SERIR 50 field cabinet
Each cabinet must be supplied by 230 Vac and by copper or, through a special converter, by optical fibre data line.
If the signals do not need to be centralized over DEA NET, the field cabinet will have a stand-alone configuration. In this case, the alarm, tamper and failure signals are available through relays (C/NC contacts) provided by the processing boards and by the SC-ER8 relay expansion boards (if any). The sensitivity calibration and the configuration parameters are performed from a laptop connected to the RS-232 serial port of the processing board.
SERIR
50
INFO
RMATIVE BRO
CHURE
Chapter
SERIR 50
17
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
DEA NET CENTRALIZATION
SYSTEM02The alarm signals generated by the processing boards can be centralized using DEA NET system, a high-speed bidirectional communication network. DEA NET interfaces Dea Security's perimeter intrusion detection systems to a control panel or to a supervision software, and can integrate third-party detection systems into a unique perimeter protection system.
DEA NET allows you to manage the system from a single remote station, simplifying its configuration and ordinary maintenance. The relevant software allows you to calibrate and program all the processing boards connected over the network, to check the inputs and the outputs status, to view in real time the signals coming from the sensors and to download the event logs.
18
DEA
NET
CEN
TRAL
IZAT
ION
SYS
TEM
SERIR
50 THE COMPONENTS OF THE SYSTEM2.1
2.1.1 THE NETWORK CONTROLLERSDEA NET is a bidirectional communication network using special electronic controllers which gather the alarm, tamper and failure signals raised by the processing boards placed inside the field cabinets and send them to the control panel or to the security management software (please see page 23).
To design the communication network, two types of controllers are available: DN CONTROLLER (SC-DN-CTRL part no), which uses DEA NET proprietary protocol to communicate both with the processing boards and 3rd party devices, and DN ETHERNET CONTROLLER (SC-DN-ETHCTRL part no) which communicates over Ethernet by means of TCP/IP and UDP/IP standard protocols.
DN CONTROLLER is generally placed in the control room or near the control panel and can manage up to 100 processing boards and 256 programmable relay outputs. DN ETHERNET CONTROLLER is usually placed inside the field cabinets and can manage up to 16 boards and 64 programmable relay outputs.
Both controllers are supplied with a service software for Microsof Windows which allows you to set up all the parameters of the processing boards placed inside the field cabinets and to view the event logs stored in the boards. The connection to the system can occur through the RS-232 serial port present on the two Controllers or over Ethernet (the latter only for DN ETHERNET CONTROLLER).
DEA NET controllers make it possible:
� to take the alarm signals through special relay expansions boards (SC-DN-ER16) for the connection and integration with the control panel or with the videosurveillance system (CCTV);
� from a laptop, to set up all the parameters of the processing boards inside the field cabinet; � to use DEA MAP security management software; � to integrate DEA systems into third-party security management software by means of DN MANAGER
interface board (for DN CONTROLLER only) or DEA MAP DLL dynamic library software.
2.1.2 DN HT REPEATER NETWORK NODEThe centralization with DN CONTROLLER involves the use of DN HT REPEATER (SC-DN-HTRPT part no), which is an interface device between the controller and the processing boards. It creates two different serial connection lines: a full-duplex one, for the communication with DN CONTROLLER and other DN HT REPEATERs (if any); and a half-duplex one (bus), for the communication with the processing boards.
19
DEA NET CEN
TRALIZATION
SYSTEMSERIR
50
DN HT REPEATER also has the task to amplify and regenerate the signals over DEA NET, so as to cover longer distances. The maximum distance between the two DN HT REPEATERs or between the DN CONTROLLER and the frst DN HT REPEATER is 2 km with FTP cable cat. 5, 5 km with multi-mode fiber and 50 km with single-mode fiber (a special converter is needed to use the optical fiber). The maximum length of the bus between an HT REPEATER and the farthest processing board, which can be designed with an FTP cable cat. 5 or with a twisted pair cable for EIA RS-485 applications, is instead 1.5 km.
DN HT REPEATER is also available in a high-insulation version, named DN HT REPEATER AS (SC-DN-HTRPTAS part no) which has been designed for environments highly disturbed by electromagnetic emissions. Its logical functions are the same as the ones of the standard model.
2.1.3 EXPANSION AND INTERFACE BOARDS
2.1.3.1 DN ER16 relay expansion board (SC-DN-ER16 part no)This board allows you to transfer the signals coming from DEA NET on C/NC/NO contacts. It provides 16- relay outputs which can be configured via software from DN CONTROLLER or DN ETHERNET CONTROLLER.
DN ER16 board allows you to interface DEA detection systems with the control panel or other videosurveillance systems and operate actuators placed along the perimeter reached by DEA NET.
2.1.3.2 DN I/O interface board (SC-DN-IO part no)This board allows to send over DEA NET the alarm signals generated by third-party devices provided with relay outputs, such as reed switches and IR/MW barriers. DN I/O provides auxiliary relay outputs which allow to send commands to the equipment in the field. DN I/O board provides 4 triple balanced NC inputs and 4 digital inputs that can be configured via software. They also provide 2 relay outputs which can be both configured by means of DN CONTROLLER or DN ETHERNET CONTROLLER. A special version of this board, DN I/O LP (SC-DN-IOLP part no), is also available. It can be programmed to perform logical operations on the inputs by means of a programming software based on the Ladder Logic graphical standard. The result of the logical operation can be used both to activate local physical relays and to send fully configurable signals to DEA NET.
2.1.3.3 DN MANAGER interface board (SC-DN-MNG part no)It is an interface board which allows to send and receive signals over DEA NET by means of a clear protocol, making it possible the integration of DEA Security detection systems with third-party management software. DN MANAGER board has to be connected to DN CONTROLLER and communicates with third-party software by means of a RS-485 full-duplex serial port. The integration of DEA Security detection systems with third-party software can be performed through DEA MAP DLL dynamic library software.
2.1.4 DN DEA POWER POWER SUPPLY UNIT (AL-DN-DEAPW)DN DEA POWER is a microprocessor stabilized linear power supply unit which can be connected over DEA NET. Unlike a normal power supply, DN DEA POWER sends over DEA NET the critical information about the supply of the system, such as output voltage and current, backup battery voltage and current, battery recharge status, mains voltage, digital inputs and serial link status. By means of DEA NET, this information can be monitored in real time from a remote location. DN DEA POWER has 4 programmable digital inputs which enable it to perform additional functions, such as the management of tamper-proof devices (tamper and burglary-proof). It is also provided with an event digital memory which can be useful to determine the cause of possible failures along the power supply circuit.
20
DEA
NET
CEN
TRAL
IZAT
ION
SYS
TEM
SERIR
50
2.2.1 CENTRALIZATION WITH DN CONTROLLERThanks to the versatility of DN HT REPEATER network node, DN CONTROLLER allows you to design DEA NET with a distributed topology, with a star topology or with a hybrid topology (the latter is a combination of the first two topologies).
In the distributed topology, full-duplex DEA NET line is used as a communication backbone to connect DN CONTROLLER, placed inside the centralization cabinet (“box 0”), with the HT REPEATERs placed inside the field cabinets. Each DN HT REPEATER creates an independent bus for each field cabinet.
CENTRALIZATION SCHEMES2.2
2.1.5 THE CONNECTION CABLEAs already mentioned, the connection between DN CONTROLLER and DN HT REPEATER and the one between two or more DN HT REPEATERs can be executed by using an FTP cable cat. 5 or superior. DEA Security can supply an FTP cable (CV-DN part number) which follows the TIA/EIA 568 cat. 5e standards. In addition to the high quality of its components, this cable is featured by a thermoplastic double sheath and a rodent-proof stainless steel braid armour. The CV-DN cable is available in reels of 250 and 500 metres.
2.1.6 IL SOFTWARE
2.1.6.1 Libreria DEA MAP DLL (cod. SW-DM-DLL)DEA MAP DLL is a software library for Microsof Windows which allows to integrate the signals raising from DN ETHERNET CONTROLLER and DN CONTROLLER into third-party software. When used in combination with DN CONTROLLER, the library needs DEA MAP SERVER (SW-DM-SRV part no) interface software.
2.1.6.2 Software di centralizzazione ETHERNET SHARER (cod. SW-ETHSHR)DN ETHERNET SHARER software allows to design and manage a network of DN ETHERNET CONTROLLERs connected to each other by means of an IEEE 802.3 Ethernet network. Thanks to this software, all the resources (processing boards and interface boards) connected to a DN ETHERNET CONTROLLER through DEA NET bus can be shared and managed also by all the other DN ETHERNET CONTROLLERs of the network.
Distributed topology Star topology
21
DEA NET CEN
TRALIZATION
SYSTEMSERIR
50
Centralization with single-mode or multi-mode fiber
In the star topology, instead, more communication buses are created. They come out of the centralization cabinet and branch out to the different field cabinets. In this case all DN HT REPEATERs used to realize each bus derivation are placed inside the centralization cabinet. The main limitation of this kind of configuration is that it is not possible to connect more than 16 processing boards for each branch of the DEA NET bus; in addition, each branch can cover a maximum distance of 1.5 km.
DEA MAP DLL
Sistema di supervisione di terze parti
2.2.2 CENTRALIZATION WITH DN ETHERNET CONTROLLERThe typical centralization model over Ethernet involves a DN ETHERNET CONTROLLER placed inside each field cabinet and connected to up to 16 processing boards by means of DEA NET bus.
DN ETHERNET CONTROLLER can also be placed inside the centralization cabinet and a DN HT REPEATER node can be used to connect the controller to one or more field cabinets.
Apart from the solution chosen, each DN ETHERNET CONTROLLER communicates over Ethernet by means of RJ45 port. The connection can be made with FTP cable cat. 5 or, using suitable media converters, with optical fiber. If the connection is made with FTP cable cat. 5, the distance between cabinet and Ethernet network cannot exceed 100 metres.
SERIR
50
INFO
RMATIVE BRO
CHURE
Chapter
SERIR 50
23
DEA MAPSECURITY
MANAGEMENT SOFTWARE03
DEA MAP is a software for the supervision and the management of one or more DEA Security detection systems connected to DEA NET centralization system. It integrates, in a single management system, both the perimeter intrusion detection system and the videosurveillance system (CCTV), displaying the protected area on a graphical map. This user-friendly software allows you the immediate identification of the zone concerned by a possible intrusion.
DEA MAP also allows you the direct interaction with the processing boards present in the field and the management, by means of DN I/O interface boards, of third-party devices provided with relay outputs (e.g. magnetic contacts and IR/MW barriers).
Depending on the version, this software provides a comprehensive management of IP cameras and their video streamings, which can be recorded, archived and replayed. Thanks to the Video Wall feature, up to 16 video streamings can be viewed at the same time, each of them on an independent window.
DEA MAP software can be used on different terminals (multi-terminal mode) and allows you to set up different privileges for each user (multi-user).
24
SO
FTW
ARE
DEA
MAP
SERIR
50
3.1.1 THE GRAPHICAL MAPThe main window of the software displays a graphical map which enables you to locate and identify, by means of icons and other graphical elements, the alarm zones and the cameras. The icons can be assigned to single devices in the field, such as sensors, sensor-strings and fixed or mobile cameras, and their colour shows the real-time status.
DEA MAP can manage multilevel maps, by selecting them from a tree-view menu which is organized into folders and sub-folders. Each map can be linked to other maps displaying different areas of the protected site, e.g. a specific floor of a building.
DEA MAP can import maps from the most common vectorial and bitmap formats.
3.1.2 THE MANAGEMENT OF THE DETECTION SYSTEMSDEA MAP allows you to manage systems of any complexity through a modern and user-friendly graphical interface. By software, it is also possible to add, modify and configure the alarm zones, by grouping them according to logical criteria (e.g. depending on the type of access to protect) or topographical criteria (e.g. all the sensors from the same storey of a building).
In addition, DEA MAP allows you to disable or bypass sensor-strings, sensor-modules or groups of sensors and to plan these actions at set times.
Exclusive feature of DEA MAP management software is the possibility of varying, with a simple mouse click, the detection capability of the whole system or part of it, so as to immediately react to any sudden change in the security risk level of the protected site. This capability acknowledges the alarm level standards (green, yellow and red) accepted by the international security agencies.
3.1.3 ALARM HANDLING For each alarm event specific actions and customized audio/video warnings can be programmed:
� logging of the alarm signals and of the user's actions � automatic recall of the associated camera stream � video streaming recording
The alarms can be sorted following a priority criterion and the installer can define custom user's actions.
Both the alarm log and the system warnings provide advanced searching, sorting, grouping and statistical analysisfunctions. The logs can be saved as a Microsof Excel file.
3.1.4 CCTV SYSTEM MANAGEMENTDEA MAP provides a complete management of the videosurveillance system: remote control of the IP cameras (dome and PTZ) and their integration into the graphical map of the perimeter. The video streamings can be viewed on the user's request or on alarm event and recorded for a playback viewing. Thanks to the Videwall feature, 16 video streamings can be viewed at the same time, each of them on an independent window.
The video recording can be continuous or can occur at predefined times or activated by an alarm event. By clicking on an alarm event in the log window, the video streamings or the recording of the concerned camera can be viewed immediately.
MAIN FEAUTURES3.1
25
SOFTW
ARE DEA MAP
SERIR
50
Three versions of DEA MAP are available: BASIC and ADVANCED, respectively for the management of small and medium/large sites, and FULL for complex sites.
DEA MAP BASIC displays the functionalities of a graphical map, without the video management. It is therefore suitable for supervising sites with no videosurveillance system or where the latter is managed by third-party software.
DEA MAP ADVANCED includes the management of the videosurveillance system, to record, file and reproduce the IP camera video streamings.
DEA MAP FULL, besides displaying the same features as the ADVANCED version, can manage a greater number of graphical elements and video streamings, can support more than 32 network controllers and share the video recording among different video servers (Load Balancing and Failover).
DEA MAP SOFTWARE VERSIONS3.2
Immediate change of the alarm levels
APPL
ICAT
ORY
EXA
MPL
ES
28
SERIR
50
JTBX-ST50termination
JTBX-ST50junction
SN-SR50SN-SR50
Installation of SN-SR50 sensors
How to fix the sensor to the fence
THE ELEMENTS OF THE SYSTEM4.1
APPLICATORY EXAM
PLES
29
SERIR
50
+--
230 Vca line
FTP cat. 5 DEA NET cable
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
SERIRA - 03 ASR - 2
String 1
50 m zone
CV-ST50 cable
max 200 m
String 4
String 2 String 3
JTBX-ST50
SC-SR50-Z4 processing board SC-DN-ER16 relay expansion board
SC-DN-HTRPTinterconnection boardAL-DN-DEAPW power supply unit
Backup ba�ery
junctionJTBX-ST50
junction
JTBX-ST50junction
JTBX-ST50termination
JTBX-ST50termination
JTBX-ST50termination
JTBX-ST50termination
Typical configuration of a SERIR 50 field cabinet (4 zones)
APPL
ICAT
ORY
EXA
MPL
ES
30
SERIR
50
Gate
Sens
or-s
trin
g 7
(inpu
t 3)
Sens
or-s
trin
g 8
(inpu
t 4)
Sens
or-s
trin
g 3
(inpu
t 3)
Sens
or-s
trin
g 4
(inpu
t 4)
Sensor-string 1 (input 1)
Linea-sensori 5 (input 1)
Sensor-string 2 (input 2)
Linea-sensori 6 (input 2)
box1
box0
box2
DEA NET
Cont
rol
pane
l
Example of protection of a 400-metre fence. The site to be protected is surrounded by welded metal fence with 2-metre spacing between the posts. A sliding gate is also present.
� Metal fence protection: - no 8 sensor-strings LN-SR50-200 model, corresponding to 8 alarm zones of 50 metres each.
� Gate protection: - possibility of using third-party detectors (IR/MW barriers) by means of DN I/O interface board to send signals over DEA NET.
� Centralization system: - no 2 field cabinets (box1, box2) containing the processing boards and the interface boards;
- no 1 centralization cabinet (box0) containing the network controller and the relay expansions.
EXAMPLES OF PROTECTION4.2
APPLICATORY EXAM
PLES
31
SERIR
50
Bill of materials for the execution of the system described on the previous page:
Box2 cabinet and electronic boardsQ.ty Part number Description
1 AP-1C IP44 pre-assembled polyester cabinet
1 AL-DN-DEAPW Microprocessor stabilized power supply unit 2,5A – 13,8Vdc
1 SC-DN-HTRPT Interconnection board for DEA NET
1 SC-SR50-Z4 SERIR 50 multi-zone processing board
Sensor-strings, cable and wiring accessoriesQ.ty Part number Description
8 LN-SR50-200 SERIR 50 sensor-string prewired with 25 sensors 2-metre spacing from post to post
as needed CV-ST50 SERIR 50/TORSUS 50 connection cable
16 FPM-100 UV resistant tie-wraps
16 JTBX-ST50 SERIR 50/TORSUS 50 junction and termination case
8 RP-100 100-gram polyurethane resin for junction and termination case
Box0 cabinet and electronic boardsQ.ty Part number Description
1 AP-2C IP44 pre-assembled polyester cabinet
1 AL-DN-DEAPW Microprocessor stabilized power supply unit 2,5A – 13,8Vdc
1 SC-DN-CTRL Controller for DEA NET
1 SC-DN-HTRPT Interconnection board for DEA NET
2 SC-DN-ER16 16-relay expansion board for DEA NET
Box1 cabinet and electronic boardsQ.ty Part number Description
1 AP-1C IP44 pre-assembled polyester cabinet
1 AL-DN-DEAPW Microprocessor stabilized power supply unit 2,5A – 13,8Vdc
1 SC-DN-HTRPT Interconnection board for DEA NET
1 SC-DN-IO Input/Output board for DEA NET
1 SC-SR50-Z4 SERIR 50 multi-zone processing board
TECH
NIC
AL F
EAUT
URES
34
SERIR
50
TECHNICAL FEAUTURES
Prewired sensor-string of 50 metres long. One string can be composed of 25, 20 or 16 SN-SR50 sensors according to the fence width which can be 2, 2.5 or 3 metres.
SERIR 50 sensor-stringpart number LN-SR50
Should you need sensor-strings with customized lengths (less than 50 metres), you have to order the needed number of SN-SR50 sensors referring to the part number table on page 33. These sensors are supplied prewired in a string.
The LN-SR50 sensor-string must be connected to either SC-SR50-Z1 or SC-SR50-Z4 processing board by means of CV-ST50 cable. The length of the cable connecting the sensor-string to the relevant processing board cannot be more than 150 metres.
SERIR 50 sensor-string is available in the following versions:
Please see SN-SR50 sensor on page 35.
technical data
PART NUMBER DESCRIPTIONSENSOR
SPACING (m)NO OF SENSORS
EACH STRING COLOUR
LN25-SR50-200G SERIR 50 prewired sensor-string 2 25 GREY
LN20-SR50-250G SERIR 50 prewired sensor-string 2.5 20 GREY
LN16-SR50-300G SERIR 50 prewired sensor-string 3 16 GREY
LN25-SR50-200V SERIR 50 prewired sensor-string 2 25 GREEN
LN20-SR50-250V SERIR 50 prewired sensor-string 2.5 20 GREEN
LN16-SR50-300V SERIR 50 prewired sensor-string 3 16 GREEN
TECHN
ICAL FEAUTURES
35
SERIR
50
TECHNICAL FEAUTURES
Piezodynamic sensor prewired in a sensor-string with customized length (less than 50 metres) and with 2m, 2.5m or 3m distance between the sensors.
SERIR 50 sensorpart number SN-SR50
The sensor-string composed of SN-SR50 sensors must be connected to either SC-SR50-Z1 or SC-SR50-Z4 processing board by means of CV-ST50 cable. The length of the cable connecting the sensor-string to the relevant processing board cannot be more than 150 metres.
SERIR 50 sensor is available in the following versions:
Sensor: • Compliance: Directive 2014/30/EU -intrinsically benign
apparatus • Dimension: 85 x 45 mm (Ø x H) • Operating temperature: -40 ÷ +80 °C • Relative humidity: 0 – 100% • Material: glass fibre reinforced ABS housing, sealed with epoxy
and UV resistant • Mounting plate: powder-coated galvanized iron back mounting
plate • Coverage area: up to 3 x 3 m (maximum Dimension of the
fence panel with sensor in mid-position) • Colour: grey or green
Connection cable: please see CV-ST50 cable on page. 38.
technical data
PART NUMBER DESCRIPTIONSENSOR
SPACING (m)
MAX NO OF SENSORS EACH
STRINGCOLOUR
SN-SR50-200G SERIR 50 sensor prewired in a sensor-string 2 25 GREY
SN-SR50-250G SERIR 50 sensor prewired in a sensor-string 2.5 20 GREY
SN-SR50-300G SERIR 50 sensor prewired in a sensor-string 3 16 GREY
SN-SR50-200V SERIR 50 sensor prewired in a sensor-string 2 25 GREEN
SN-SR50-250V SERIR 50 sensor prewired in a sensor-string 2.5 20 GREEN
SN-SR50-300V SERIR 50 sensor prewired in a sensor-string 3 16 GREEN
TECH
NIC
AL F
EAUT
URES
36
SERIR
50
TECHNICAL FEAUTURES
Prewired sensor-string of 50 metres long, with cable protected by flexible metal sheath. One string can be composed of 25, 20 or 16 SN-SR50-GM sensors according to the fence width which can be 2, 2.5 or 3 metres.
SERIR 50 sensor-string with metal sheathpart number LN-SR50-GM
Should you need sensor-strings with customized lengths (less than 50 metres), you have to order the needed number of SN-SR50-GM sensors referring to the part number table on page 35. These sensors are supplied prewired in a string.
The LN-SR50-GM sensor-string must be connected to either SC-SR50-Z1 or SC-SR50-Z4 processing board by means of CV-ST50 cable. The length of the cable connecting the sensor-string to the relevant processing board cannot be more than 150 metres.
SERIR 50 sensor-string with cable protected by flexible metal sheath is available in the following versions:
Please see SN-SR50-GM sensor on page 37.
TECHNICAL DATA
PART NUMBER DESCRIPTIONSENSOR
SPACING (m)
MAX NO OF SENSORS EACH
STRINGCOLOUR
LN25-SR50-GM200SERIR 50 sensor prewired in a string and with
cable protected by flexible metal sheath2 25 GREY
LN20-SR50-GM250SERIR 50 sensor prewired in a string and with
cable protected by flexible metal sheath2.5 20 GREY
LN16-SR50-GM300SERIR 50 sensor prewired in a string and with
cable protected by flexible metal sheath3 16 GREY
TECHN
ICAL FEAUTURES
37
SERIR
50
TECHNICAL FEAUTURES
SN-SR50 sensor prewired in a sensor-string with connection cable protected by flexible metal sheath for a higher mechanical resistance.
SERIR 50 sensor with metal sheathpart number SN-SR50-GM
The sensor-string composed of SN-SR50-GM sensors must be connected to either SC-SR50-Z1 or SC-SR50-Z4 processing board by means of CV-ST50 cable. The length of the cable connecting the sensor-string to the relevant processing board cannot be more than 150 metres.
SERIR 50 sensor with cable protected with flexible metal sheath is available in the following versions:
Sensor: • Colour: grey • For further information, please see the technical data of the
SN-SR50 sensor on page. 35.
Connection cable: • Diameter sheath: 10 mm • Material sheath: galvanized steel with single seam and PVC
vacuum covered • Colour sheath: grey • For further technical data, please see CV-ST50 cable on page
38.
Technical data
PART NUMBER DESCRIPTIONSENSOR
SPACING (m)
MAX NO OF SENSORS EACH
STRINGCOLOUR
SN-SR50-GM200SERIR 50 sensor prewired in a string and with
cable protected by flexible metal sheath2 25 GREY
SN-SR50-GM250SERIR 50 sensor prewired in a string and with
cable protected by flexible metal sheath2.5 20 GREY
SN-SR50-GM300SERIR 50 sensor prewired in a string and with
cable protected by flexible metal sheath3 16 GREY
TECH
NIC
AL F
EAUT
URES
38
SERIR
50
TECHNICAL FEAUTURES
Tinned copper two-wire shielded cable for the connection of LN-SR50 sensor-string or SN-SR50 and SN-SR50-GM sensors prewired in a string to either SC-SR50-Z1 or SC-SR50-Z4 processing board.
SERIR 50/TORSUS 50 cablepart number CV-ST50
SERIR 50/TORSUS 50 cable is available in hanks of 25, 50, 100, 200 metres and in reels of 500 metres.
• Compliance: Directive 2006/95/CE, CEI 20-11, CEI 20-14 p.q.a., CEI 20-35/1-2, EN 50363, EN 60332-1-2, IEC 60332-1, UL 1581, RoHS, REACH
• Diameter: 6.2 mm • Wires: 2 twisted tinned copper wires • Cross sectional area: 0.25 mm² (24 AWG) • Operating temperature:
Ì -40 ÷ +80 °C (fixed installation) Ì -15 ÷ +80 °C (mobile installation)
• Installation temperature: -15 ÷ +50 °C • Insulation voltage: 0.6/1 kV • Wire insulation material: polyolefin • Shielding:
Ì tinned copper braid (coverage >90%) Ì aluminium/polyester foil screen (coverage >100%) with
tinned copper drain wire with cross sectional area of 0.25 mm² (24 AWG)
• Double jacket: special flame retardant PVC compound, quality TM2/RZ
• Bending radius: 15 times outer diameter • Use: this cable can be installed in a group of cables with max
operating voltage of Uo/U 0.6/1 kV • Colour: grey or green
technical data
PART NUMBER DESCRIPTION LENGTH (m) COLOUR
CV-ST50-25G SERIR 50/TORSUS 50 connection cable 25 GREY
CV-ST50-50G SERIR 50/TORSUS 50 connection cable 50 GREY
CV-ST50-100G SERIR 50/TORSUS 50 connection cable 100 GREY
CV-ST50-200G SERIR 50/TORSUS 50 connection cable 200 GREY
CV-ST50-500G SERIR 50/TORSUS 50 connection cable 500 GREY
CV-ST50-25V SERIR 50/TORSUS 50 connection cable 25 GREEN
CV-ST50-50V SERIR 50/TORSUS 50 connection cable 50 GREEN
CV-ST50-100V SERIR 50/TORSUS 50 connection cable 100 GREEN
CV-ST50-200V SERIR 50/TORSUS 50 connection cable 200 GREEN
CV-ST50-500V SERIR 50/TORSUS 50 connection cable 500 GREEN
TECHN
ICAL FEAUTURES
39
SERIR
50
TECHNICAL FEAUTURES
Prewired sensor-string of 50 metres long. One string can be composed of 25, 20 or 16 SN-SR50-P polyamide sensors according to the fence width which can be 2, 2.5 and 3 metres.
SERIR 50 sensor-string with polyamide sensorspart number LN-SR50-P
Should you need sensor-strings with customized lengths (less than 50 metres), you have to order the needed number of SN-SR50-P sensors referring to the part number table on page 34. These sensors are supplied prewired in a string.
The LN-SR50-P sensor-string must be connected to either SC-SR50-Z1 or SC-SR50-Z4 processing board by means of CV-ST50-P cable. The length of the cable connecting the sensor-string to the relevant processing board cannot be more than 150 metres.
SERIR 50 sensor-string with polyamide sensor is available in the following versions:
Please see SN-SR50-P sensor on page 40.
technical data
PART NUMBER DESCRIPTIONSENSOR
SPACING (m)NO OF SENSORS
EACH STRING COLOUR
LN25-SR50-P200NSERIR 50 sensor-string prewired with
polyamide sensors2 25 BLACK
LN20-SR50-P250NSERIR 50 sensor-string prewired with
polyamide sensors2.5 20 BLACK
LN16-SR50-P300NSERIR 50 sensor-string prewired with
polyamide sensors3 16 BLACK
TECH
NIC
AL F
EAUT
URES
40
SERIR
50
TECHNICAL FEAUTURES
SN-SR50P polyamide sensor prewired in a sensor-string; it is highly resistant to UV, abrasion and direct contact with crude oil and petroleum products.
SERIR 50 polyamide sensorpart number SN-SR50-P
The sensor-string composed of SN-SR50-P sensors must be connected to either SC-SR50-Z1 or SC-SR50-Z4 processing board by means of CV-ST50-P cable. The length of the cable connecting the sensor-string to the relevant processing board cannot be more than 150 metres.
SERIR 50 polyamide sensor is available in the following versions:
Sensore: • Compliance: Directive 2014/30/EU - intrinsically benign
apparatus • Dimension: 85 x 45 mm (Ø x H) • Operating temperature: -40 ÷ +80 °C • Relative humidity: 0 – 100% • Material: glass fiber reinforced polyamide housing, sealed with
epoxy; resistant to UV, abrasion, oils and hydrocarbons • Mounting plate: stainless steel back mounting plate • Coverage area: max 3 x 3 m (maximum Dimension of the fence
panel with sensor in mid-position) • Colour: black
Connection cable: please see CV-ST50-P cable on page 41.
technical data
PART NUMBER DESCRIPTIONSENSOR
SPACING (m)
MAX NO OF SENSORS EACH
STRINGCOLOUR
SN-SR50-P200N SERIR 50 polyamide sensor prewired in a sensor-string 2 25 BLACK
SN-SR50-P250N SERIR 50 polyamide sensor prewired in a sensor-string 2.5 20 BLACK
SN-SR50-P300N SERIR 50 polyamide sensor prewired in a sensor-string 3 16 BLACK
TECHN
ICAL FEAUTURES
41
SERIR
50
TECHNICAL FEAUTURES
Tinned copper two-wire shielded cable, with polyurethane external jacket. Highly resistant to UV, abrasion and direct contact with crude oil and petroleum products.
This cable is used to connect LN-SR50-P sensor-string and SN-SR50-P sensors prewired in a string to either SC-SR50-Z1 or SC-SR50-Z4 processing boards.
SERIR 50/TORSUS 50 polyurethane cablepart number CV-ST50-P
SERIR 50/TORSUS 50 poyurethane cable is available in hanks of 50, 100, 200 metres and in reels of 500 metres.
• Compliance: Directive 2006/95/CE, CEI 20-11, CEI 20-14 p.q.a., CEI 20-35/1-2, EN 50363, EN 60332-1-2, IEC 60332-1, UL 1581, VDE 0282-10, RoHS, REACH
• Diameter: 6.3 mm • Wires: 2 twisted tinned copper wires • Cross sectional area: 0.25 mm² (24 AWG) • Operating temperature:
Ì -40 ÷ +80 °C (fixed installation) Ì -40 ÷ +80 °C (mobile installation)
• Installation temperature: -40 ÷ +50 °C • Insulation voltage: 0.6/1 kV • Wires insulation material: polyolefin • Shielding:
Ì tinned copper braid (coverage >90%) Ì aluminium/polyester foil screen (coverage >100%) with
tinned copper drain wire with cross sectional area of 0.25 mm² (24 AWG
• Inner jacket: special flame retardant PVC compound, quality TM2/RZ
• Jacket: mat polyurethane; resistant to UV rays, oils, hydrocarbons, hydrolisis and abrasions
• Bending radius: 15 times outer diameter • Use: this cable can be installed in a group of cables with max
operating voltage of Uo/U 0.6/1 kV • Colour: black
technical data
PART NUMBER DESCRIPTION LENGTH (m) COLOUR
CV-ST50-P50N SERIR 50/TORSUS 50 polyurethane connection cable 50 BLACK
CV-ST50-P100N SERIR 50/TORSUS 50 polyurethane connection cable 100 BLACK
CV-ST50-P200N SERIR 50/TORSUS 50 polyurethane connection cable 200 BLACK
CV-ST50-P500N SERIR 50/TORSUS 50 polyurethane connection cable 500 BLACK
TECH
NIC
AL F
EAUT
URES
42
SERIR
50
TECHNICAL FEAUTURES
UV resistant polyamide case for junction and termination of SERIR 50 sensor-strings. Supplied with a printed circuit board to simplify the wiring procedures.
SERIR 50/TORSUS 50 junction/termination casepart number JTBX-ST50
PART NUMBER DESCRIPTION COLOUR
JTBX-ST50 SERIR 50/TORSUS 50 junction/termination case BLACK
To be wired with CV-ST50 or CV-ST50-P cable and to be sealed with RP-100 two-component polyurethane resin.
• Dimension: 30 x 30 x 114 mm (L x W x H) • Operating temperature: -40 ÷ +80 °C • Relative humidity: 0 – 100% (after sealing with RP-100
polyurethane resin) • Material: glass fiber reinforced polyamide • Colour: black
technical data
TECHN
ICAL FEAUTURES
43
SERIR
50
TECHNICAL FEAUTURES
Microprocessor electronic board which manages one SERIR 50 sensor-string. This board amplifies, digitizes and analyses the signals coming from the sensor-string, discriminating the typical signals of an intrusion from the ones generated by environmental nuisances.
SERIR 50 single-zone processing boardpart number SC-SR50-Z1
PART NUMBER DESCRIPTION
SC-SR50-Z1 SERIR 50 single-zone processing board
• Compliance: Directive 2014/30/EU, EN 50130-4:2011, EN 61000-6-3:2007+A1:2011:2007+A1:2011
• Power supply: 12 Vdc (min 11 V - max 15 V) • Current: 65 mA (standby) – 80 mA (max) • Operating temperature: -25 ÷ +80 °C • Relative humidity: <95% non condensing • Board Dimension: 113 x 79 mm (B x H) • Mounting plate Dimension: 133 x 81 mm (B x H) • Analog input for 1 sensor-string with resistor balancing • Optoinsulated digital auxiliary inputs for supplementary
commands: Ì Reset Ì ATM (atmospheric control) Ì ARM (event storage) Ì Tamper (cabinet)
• NC relay outputs (1 A): Ì Tamper Ì Alarm
• OC outputs (which can be converted into C/NC/NO by means of 1-relay expansion board SC-ER1):
Ì Prealarm Ì Sporadic cut alarm
• Analysis capability: Ì up to 25 SERIR 50 detectors
• Calibration, settings and event management via software • Connection to PC (by means of RS-232 port) and to modem (by
means of COM X port adapter) • Possibility of connection over DEA NET centralization network • CPU: 16 bits, 16 MHz • Digital memory: more than 20.000 events • Service software licence included
technical data
TECH
NIC
AL F
EAUT
URES
44
SERIR
50
TECHNICAL FEAUTURES
Microporcessor electronic board which manages four SERIR 50 sensor-strings. This board amplifies, digitizes and analyses the signals coming from the sensor-strings, discriminating the typical signals of an intrusion from the ones generated by environmental nuisances.
SERIR 50 multi-zone processing boardpart number SC-SR50-Z4
PART NUMBER DESCRIPTION
SC-SR50-Z4 SERIR 50 multi-zone processing board
• Compliance: Directive 2014/30/EU, EN 50130-4:2011, EN 61000-6-3:2007+A1:2011:2007+A1:2011
• Power supply: 12 Vdc (min 11 V - max 15 V) • Current: 110 mA (standby) – 220 mA (max) • Operating temperature: -25 ÷ +80 °C • Relative humidity: <95% non condensing • Board Dimension: 180 x 130 mm (B x H) • Mounting plate Dimension: 200 x 130 mm (B x H) • Analog inputs for 4 sensor-strings with resistor balancing • Optoinsulated digital auxiliary inputs for supplementary
commands: Ì Reset Ì ATM (atmospheric control) Ì ARM (event storage) Ì Tamper (cabinet)
• NC relay outputs (1 A): Ì General Tamper Ì Alarms from sensor-strings 1, 2, 3, 4 Ì Low battery
• Supplementary NC outputs by means of 8-relay expansion board SC-ER8:
Ì 4 for Prealarm Ì 4 for Sporadic Cut Alarm
• Analysis capability (each line): Ì up to 25 SERIR 50 detectors
• Calibration, settings and event management via software • Connection to PC (by means of RS-232 port) and to modem (by
means of COM X port adapter) • Possibility of connection over DEA NET centralization network • CPU: 16 bits, 16 MHz • Digital memory: more than 20.000 events • Service software licence included
technical data
TECHN
ICAL FEAUTURES
45
SERIR
50
TECHNICAL FEAUTURES
NC 8-relay expansion board to be connected to SC-SR50-Z4, SC-TR50-Z4, SC-SMCA-CTRL and SC-SMCAPF-CTRL boards.The functions of each relay are determined by the motherboard.
8-relay expansion boardpart number SC-ER8
PART NUMBER DESCRIPTION
SC-ER8 8-relay expansion board
1-relay expansion board to convert OC outputs into C/NC/NO contacts.
1-relay expansion boardpart number SC-ER1
PART NUMBER DESCRIPTION
SC-ER1 1-relay expansion board (OC into C/NC/NO)
• Power supply: 12 Vdc (min 11 V - max 15 V) • Current: 12 mA • Operating temperature: -25 ÷ +80 °C • Relative humidity: <95% non condensing • Board Dimension: 36 x 32 mm (B x H) • OC signal input • Relay output (1 A): C/NC/NO
technical data
• Compliance (if connected to SC-SR50-Z4, SC-TR50-Z4, SC-SMCA-CTRL, SC-SMCAPF-CTRL boards): Directive 2014/30/EU, EN 50130-4:2011, EN 61000-6-3:2007+A1:2011
• Power supply: 12 Vdc (from flat cable) • Current: 7 mA (standby) - 100 mA (max) • Operating temperature: -25 ÷ +80 °C • Relative humidity: <95% non condensing • Board Dimension: 110 x 63 mm (B x H) • Mounting plate Dimension: 130 x 64 mm (B x H) • Inputs: 10-pin data connector (flat cable supplied with the
board) • NC relay outputs: 8 (their functions depend on the processing
board) • Connector for successive connection of another SC-ER8 board
technical data
INFO
RMATIVE BRO
CHURE
© 2016 DEA Security S.r.l.edition September 2016 - v. 2.0.3
DEA Security S.r.l. reserve the right to vary at any moment and without notice the information and the specifications herein.
DEA Security S.r.l.Via Bolano, snc - 19037 Santo Stefano di Magra (SP)tel. +39 0187 699233 - fax +39 0187 697615 VAT No.: IT00291080455www.deasecurity.com - [email protected]