14
©2016 Acuity Brands Lighting, Inc. Sensor Switch Industrial High Bay Sensors with Bluetooth Sales Presentation

Sensor Switch Industrial High Bay Sensors with Bluetooth...SBG BTP Sensor Presentation Proprietary and Confidential SGB BTP Wet Location Application –high bay Stand alone –occ

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Sensor Switch Industrial High Bay Sensors with Bluetooth...SBG BTP Sensor Presentation Proprietary and Confidential SGB BTP Wet Location Application –high bay Stand alone –occ

©2016 Acuity Brands Lighting, Inc.

Sensor Switch –Industrial High Bay Sensors with Bluetooth

Sales Presentation

Page 2: Sensor Switch Industrial High Bay Sensors with Bluetooth...SBG BTP Sensor Presentation Proprietary and Confidential SGB BTP Wet Location Application –high bay Stand alone –occ

SBG BTP Sensor Presentation

Proprietary and Confidential

SGB BTP Wet Location

▪ Application – high bay

▪ Stand alone – occ. / dimming / photo control

▪ Compatibility – Vantage / Petrolux / Phuzion

Fixture Integrated Industrial High Bay Sensor

Page | 2

The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth

SIG, Inc. and any use of such marks by Acuity Brands is under license. Other

trademarks and trade names are those of their respective owners.

Page 3: Sensor Switch Industrial High Bay Sensors with Bluetooth...SBG BTP Sensor Presentation Proprietary and Confidential SGB BTP Wet Location Application –high bay Stand alone –occ

SBG BTP Sensor Presentation

Proprietary and Confidential

SGB BTP Wet Location

▪ Features▪ HALEON intelligence inside

▪ IP66 wet location rated

▪ Configurable via mobile app from the ground

▪ Visual Light Programming (VLP) 6-8 ft range and BlueTooth Low Energy (BTLE) – +100 ftrange

▪ Low temp / low humidity

▪ Colors: White (WH) Black (BK)

Fixture Integrated Industrial High Bay Sensor

Page | 3

Page 4: Sensor Switch Industrial High Bay Sensors with Bluetooth...SBG BTP Sensor Presentation Proprietary and Confidential SGB BTP Wet Location Application –high bay Stand alone –occ

SBG BTP Sensor Presentation

Proprietary and Confidential

Bluetooth Programming with VLP App

Page | 4

1. Select the

appropriate

Sensor

2. Select BLE for

maximum range

programming

3. Set configuration

options

4. Select multiple BLE

enabled fixtures to

batch process

configuration changes

Page 5: Sensor Switch Industrial High Bay Sensors with Bluetooth...SBG BTP Sensor Presentation Proprietary and Confidential SGB BTP Wet Location Application –high bay Stand alone –occ

SBG BTP Sensor Presentation

Proprietary and Confidential

SBG BTP Spec Sheet Overview

Page | 5

Page 6: Sensor Switch Industrial High Bay Sensors with Bluetooth...SBG BTP Sensor Presentation Proprietary and Confidential SGB BTP Wet Location Application –high bay Stand alone –occ

SBG BTP Sensor Presentation

Proprietary and Confidential

SBG BTP Spec Sheet Options

Page | 6

Example: SBG 6 SMHB OCC BTP WH LT

Page 7: Sensor Switch Industrial High Bay Sensors with Bluetooth...SBG BTP Sensor Presentation Proprietary and Confidential SGB BTP Wet Location Application –high bay Stand alone –occ

SBG BTP Sensor Presentation

Proprietary and Confidential

SBG BTP Spec Sheet – Detailed Specs

Page | 7

Page 8: Sensor Switch Industrial High Bay Sensors with Bluetooth...SBG BTP Sensor Presentation Proprietary and Confidential SGB BTP Wet Location Application –high bay Stand alone –occ

SBG BTP Sensor Presentation

Proprietary and Confidential

SBG BTP Coverage Patterns

Page | 8

Page 9: Sensor Switch Industrial High Bay Sensors with Bluetooth...SBG BTP Sensor Presentation Proprietary and Confidential SGB BTP Wet Location Application –high bay Stand alone –occ

SBG BTP Sensor Presentation

Proprietary and Confidential

SBG BTP Spec Sheet Wiring Diagram

Wiring Diagram – Driver with Aux Power and Standby mode

Page | 9

Flash Programing with VLP

Page 10: Sensor Switch Industrial High Bay Sensors with Bluetooth...SBG BTP Sensor Presentation Proprietary and Confidential SGB BTP Wet Location Application –high bay Stand alone –occ

SBG BTP Sensor Presentation

Proprietary and Confidential

Frequently Asked Questions and Trouble Shooting

▪ Can I control the light levels dynamically with the APP?

▪ Room control is not a feature implemented on the APP. The function of the APP is to configure the sensor setting rather then be dimming or on/off control.

▪ Is this a networked or standalone sensor?

▪ Stand alone, each sensor works independently

▪ So if I can program multiple sensors at the same time, that seems like a network, what am I missing?

▪ VLP App allows the user to select all sensors in Bluetooth radio range and que them up to set options. Once you push those options the app will connect to each selected sensor, one at a time, and configure it.

Integrated Bluetooth Programmable Sensors via Sensor Switch VLP

Page | 10

Page 11: Sensor Switch Industrial High Bay Sensors with Bluetooth...SBG BTP Sensor Presentation Proprietary and Confidential SGB BTP Wet Location Application –high bay Stand alone –occ

SBG BTP Sensor Presentation

Proprietary and Confidential

Frequently Asked Questions and Trouble Shooting

▪ How long does it take to configure a sensor?

▪ The app will provide feedback on the connection status and report successful configuration. The fixture will also confirm via a on-off-on “curtsy”. This process varies about 5-8 seconds / fixture

▪ How much is the APP?

▪ The Sensor Switch VLP app is free and available for iPhone and Andriod devices. See our list of recommended mobile devices for compatibility.

▪ If anyone can download the APP is my facility secure?

▪ Yes. To connect to the sensors a PIN code is required.

Integrated Bluetooth Programmable Sensors via Sensor Switch VLP

Page | 11

Page 12: Sensor Switch Industrial High Bay Sensors with Bluetooth...SBG BTP Sensor Presentation Proprietary and Confidential SGB BTP Wet Location Application –high bay Stand alone –occ

SBG BTP Sensor Presentation

Proprietary and Confidential

Frequently Asked Questions

▪ What is the default PIN code?

▪ There is no default PIN code. Upon installation you will be required to set the PIN code.

▪ I don’t know the PIN code or it was never set, now what?

▪ Upon power up after a power interruption of 30 sec the device will enter PIN overwrite mode for 45 minutes. During this time frame the device will write whatever PIN pushed from the app. A independent 6 digit PIN for Bluetooth and a 3 digit PIN for Flash programming can now be established. If no PIN changes are made during the 45 minute window the PIN remains as previously set.

▪ If I do not establish a PIN will the sensor still function?

▪ Yes. The sensor will perform according to the default settings.

▪ What options can I set with the APP?

▪ Occupancy time delay, dim to off time delay, trim levels and photocontrol options

Integrated Bluetooth Programmable Sensors via Sensor Switch VLP

Page | 12

Page 13: Sensor Switch Industrial High Bay Sensors with Bluetooth...SBG BTP Sensor Presentation Proprietary and Confidential SGB BTP Wet Location Application –high bay Stand alone –occ

SBG BTP Sensor Presentation

Proprietary and Confidential

Frequently Asked Questions

▪ Why do I have to login to the Sensor Switch VLP APP?

▪ A login gives you the benefit of being able to save profiles, we want to be able to help you remember things like PIN codes and typical configuration settings that maybe associated with particle jobs and application spaces.

▪ Are Bluetooth programmable sensors via Sensor Switch available as discreet devices?

▪ Today Bluetooth programmable sensors are offered in a select industrial high bay products. More will be released in more platforms in the future but is not currently offered as a discreet device to ensure compatibility.

Integrated Bluetooth Programmable Sensors via Sensor Switch VLP

Page | 13

Page 14: Sensor Switch Industrial High Bay Sensors with Bluetooth...SBG BTP Sensor Presentation Proprietary and Confidential SGB BTP Wet Location Application –high bay Stand alone –occ

Page | 14