SANITARY SEWER DETAILS SAN-1 SANITARY CASTING DETAIL SAN-2 TYPICAL SEWER SERVICE CONNECTION SAN-2A SEWER SERVICE CONNECTION FOR CIPP LINED SEWER MAIN SAN-3 SANITARY MANHOLE NON-PAVED AREAS SAN-3A CONCRETE ENCASED CASTING COLLAR FOR SANITARY MH IN ROADWAY, WALKS, & DRIVES SAN-4 CONSTRUCT INSIDE DROP STRUCTURE SAN-5 HDPE SANITARY SEWER PRESSURE LATERAL CONNECTION SAN-6 HDPE FORCEMAIN TO GRAVITY MAIN MANHOLE SAN-7 AIR-RELEASE MANHOLE SAN-8 CLEANOUT MANHOLE SAN-8A DEAD END CLEAN OUT HANDHOLE SAN-9 POLYETHYLENE MH ADJUSTING RING – FLAT SAN-10 POLYETHYLENE MH ADJUSTING RING - WEDGE SAN-11 PRECAST MECHANICAL JOINT SEWER MANHOLE

SANITARY SEWER DETAILS SAN-1 SAN-2 TYPICAL ......SANITARY SEWER DETAILS SAN-1 SANITARY CASTING DETAIL SAN-2 TYPICAL SEWER SERVICE CONNECTION SAN-2A SEWER SERVICE CONNECTION FOR CIPP

  • Upload
    others

  • View
    16

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SANITARY SEWER DETAILS SAN-1 SAN-2 TYPICAL ......SANITARY SEWER DETAILS SAN-1 SANITARY CASTING DETAIL SAN-2 TYPICAL SEWER SERVICE CONNECTION SAN-2A SEWER SERVICE CONNECTION FOR CIPP

SANITARY SEWER DETAILS

SAN-1 SANITARY CASTING DETAIL SAN-2 TYPICAL SEWER SERVICE CONNECTION SAN-2A SEWER SERVICE CONNECTION FOR CIPP LINED SEWER MAIN SAN-3 SANITARY MANHOLE NON-PAVED AREAS SAN-3A CONCRETE ENCASED CASTING COLLAR FOR SANITARY MH IN ROADWAY,

WALKS, & DRIVES SAN-4 CONSTRUCT INSIDE DROP STRUCTURE SAN-5 HDPE SANITARY SEWER PRESSURE LATERAL CONNECTION SAN-6 HDPE FORCEMAIN TO GRAVITY MAIN MANHOLE SAN-7 AIR-RELEASE MANHOLE SAN-8 CLEANOUT MANHOLE SAN-8A DEAD END CLEAN OUT HANDHOLE SAN-9 POLYETHYLENE MH ADJUSTING RING – FLAT SAN-10 POLYETHYLENE MH ADJUSTING RING - WEDGE SAN-11 PRECAST MECHANICAL JOINT SEWER MANHOLE

Page 2: SANITARY SEWER DETAILS SAN-1 SAN-2 TYPICAL ......SANITARY SEWER DETAILS SAN-1 SANITARY CASTING DETAIL SAN-2 TYPICAL SEWER SERVICE CONNECTION SAN-2A SEWER SERVICE CONNECTION FOR CIPP

SANITARY

AutoCAD SHX Text
NOTE: T/CAST SHALL BE .03' BELOW FINISHED PAVEMENT SURFACE.
AutoCAD SHX Text
NOTE: SUITABLE FOR HS25 WHEEL LOADS
AutoCAD SHX Text
MATERIAL: GRAY IRON CLASS 35B
AutoCAD SHX Text
SPEC.: ASTM A-48-74
AutoCAD SHX Text
WGT. 298 LBS
AutoCAD SHX Text
WGT. 122 LBS
AutoCAD SHX Text
TOTAL WEIGHT 420 LBS.
AutoCAD SHX Text
(2) CONCEALED PICKHOLE SEE PICKHOLE DETAIL
AutoCAD SHX Text
2" RAISED LETTERS FLUSH W/ LID SURFACE DESIGN
AutoCAD SHX Text
SANITARY CASTING DETAIL
AutoCAD SHX Text
SAN-1
AutoCAD SHX Text
REVISED/APPROVED 02/01/2013
AutoCAD SHX Text
CITY OF DULUTH STANDARD DETAIL DEPT. OF PUBLIC WORKS AND UTILITIES
AutoCAD SHX Text
NO SCALE
Page 3: SANITARY SEWER DETAILS SAN-1 SAN-2 TYPICAL ......SANITARY SEWER DETAILS SAN-1 SANITARY CASTING DETAIL SAN-2 TYPICAL SEWER SERVICE CONNECTION SAN-2A SEWER SERVICE CONNECTION FOR CIPP
AutoCAD SHX Text
2% MINIMUM SLOPE
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
NOTES 1. BID ITEM FOR PVC WYE INCLUDES FURNISHING AND INSTALLING WYE IN SEWER MAIN. BID ITEM FOR PVC WYE INCLUDES FURNISHING AND INSTALLING WYE IN SEWER MAIN. 2. CONNECT SEWER SERVICE INCLUDES 6" PVC SEWER SERVICE PIPE (TO 4' FROM C/L) AND ALL FITTINGS CONNECT SEWER SERVICE INCLUDES 6" PVC SEWER SERVICE PIPE (TO 4' FROM C/L) AND ALL FITTINGS 3. 6" PVC SEWER SERVICE PIPE IS INTENDED FOR THE RECONSTRUCTION OF SEWER SERVICES (WHEN FOUND TO BE IN NEED BY THE 6" PVC SEWER SERVICE PIPE IS INTENDED FOR THE RECONSTRUCTION OF SEWER SERVICES (WHEN FOUND TO BE IN NEED BY THE ENGINEER) COMPLETE IN PLACE FROM 4.0' BEYOND THE C/L OF THE SEWER MAIN TO A POINT DESIGNATED BY THE ENGINEER 4. FOR NEW SERVICES, PIPE TO STOP AT RIGHT OF WAY FOR NEW SERVICES, PIPE TO STOP AT RIGHT OF WAY 5. #12 GAUGE GREEN INSULATED COPPER TRACER WIRE SHALL BE INSTALLED WITH SANITARY SEWER MAINS AND SERVICES. TRACER WIRE #12 GAUGE GREEN INSULATED COPPER TRACER WIRE SHALL BE INSTALLED WITH SANITARY SEWER MAINS AND SERVICES. TRACER WIRE TERMINAL BOXES SHALL BE INSTALLED DIRECTLY ABOVE THE SEWER SERVICE OR AS DETERMINED BY THE ENGINEER 6. FOR SERVICES, TRACER WIRE SHALL RUN FROM THE WYE AND TERMINATE IN A FLUSH MOUNTED TRACER BOX WITH A GREEN CAST IRON FOR SERVICES, TRACER WIRE SHALL RUN FROM THE WYE AND TERMINATE IN A FLUSH MOUNTED TRACER BOX WITH A GREEN CAST IRON LOCKABLE TOP. 7. THE TRACER WIRE SHALL REMAIN CONTINUOUS TO THE GREATEST EXTENT POSSIBLE. SPLICES IN THE TRACER WIRE SHOULD BE MADE WITH THE TRACER WIRE SHALL REMAIN CONTINUOUS TO THE GREATEST EXTENT POSSIBLE. SPLICES IN THE TRACER WIRE SHOULD BE MADE WITH SPLIT BOLT CONNECTORS. WIRE NUTS SHALL NOT BE USED. A WATER-PROOF CONNECTION IS NECESSARY TO PREVENT CORROSION.
AutoCAD SHX Text
P
AutoCAD SHX Text
L
AutoCAD SHX Text
EXISTING SERVICE PIPE
AutoCAD SHX Text
NEW SERVICE ON EXISTING MAIN
AutoCAD SHX Text
MAGNESIUM ANODE (1 LB MIN.) REQUIRED WHERE NO TRACER IS INSTALLED ON MAIN
AutoCAD SHX Text
NEW SERVICE
AutoCAD SHX Text
CONTRACTOR SUPPLIED MAGNETIZED TRACER BOX WITH GREEN TOP. WIRE CONNECTED TO TRACER BOX TERMINAL.
AutoCAD SHX Text
LEAVE SLACK IN WIRE
AutoCAD SHX Text
CONNECT TO MAIN TRACER WIRE
AutoCAD SHX Text
PVC WYE
AutoCAD SHX Text
TRACER WIRE
AutoCAD SHX Text
COARSE FILTER AGGREGATE SPEC. 3149.2H3149.2H
AutoCAD SHX Text
ANGLE VARIES TO MATCH EXISTING SERVICE PIPE
AutoCAD SHX Text
NEOPRENE SLEEVE WITH STAINLESS STEEL BANDS ADAPT TO EXISTING PIPE MATERIAL (INCIDENTAL)
AutoCAD SHX Text
PVC SEWER PIPE
AutoCAD SHX Text
TYPICAL SEWER SERVICE CONNECTION
AutoCAD SHX Text
SAN-2
AutoCAD SHX Text
REVISED/APPROVED 02/19/2015
AutoCAD SHX Text
CITY OF DULUTH STANDARD DETAIL DEPT. OF PUBLIC WORKS AND UTILITIES
AutoCAD SHX Text
NO SCALE
Page 4: SANITARY SEWER DETAILS SAN-1 SAN-2 TYPICAL ......SANITARY SEWER DETAILS SAN-1 SANITARY CASTING DETAIL SAN-2 TYPICAL SEWER SERVICE CONNECTION SAN-2A SEWER SERVICE CONNECTION FOR CIPP
Page 5: SANITARY SEWER DETAILS SAN-1 SAN-2 TYPICAL ......SANITARY SEWER DETAILS SAN-1 SANITARY CASTING DETAIL SAN-2 TYPICAL SEWER SERVICE CONNECTION SAN-2A SEWER SERVICE CONNECTION FOR CIPP
AutoCAD SHX Text
NOTE: 1. ALL SEALS SHALL EXTEND FROM THE CASTING TO THE CONE ALL SEALS SHALL EXTEND FROM THE CASTING TO THE CONE 2. TRACER WIRE REQUIRED ON ALL SANITARY SEWER MAINSTRACER WIRE REQUIRED ON ALL SANITARY SEWER MAINS
AutoCAD SHX Text
EXTERNAL MANHOLE SEAL TO BE USED ON ALL MANHOLES NOT LOCATED IN PAVED AREAS
AutoCAD SHX Text
TRACER WIRE
AutoCAD SHX Text
HDPE ADJUSTING RINGS AS REQUIRED
AutoCAD SHX Text
RUBBER SLEEVE
AutoCAD SHX Text
CASTING FLANGE TO REST DIRECTLY ON ADJUSTING RING (NO SHIMS)
AutoCAD SHX Text
TOP OF CASTING SHALL BE 38" BELOW FINISHED GRADE
AutoCAD SHX Text
SANITARY MANHOLE NON-PAVED AREAS
AutoCAD SHX Text
SAN-3
AutoCAD SHX Text
REVISED/APPROVED 04/05/2019
AutoCAD SHX Text
CITY OF DULUTH STANDARD DETAIL DEPT. OF PUBLIC WORKS AND UTILITIES
AutoCAD SHX Text
NO SCALE
Page 6: SANITARY SEWER DETAILS SAN-1 SAN-2 TYPICAL ......SANITARY SEWER DETAILS SAN-1 SANITARY CASTING DETAIL SAN-2 TYPICAL SEWER SERVICE CONNECTION SAN-2A SEWER SERVICE CONNECTION FOR CIPP
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
6" MAX.
AutoCAD SHX Text
1/4"
AutoCAD SHX Text
NOTES: 1. CONCRETE (MIX NO. 3G52) COLLAR TO ENCASE CASTING AND ADJUSTMENT RING. CONCRETE (MIX NO. 3G52) COLLAR TO ENCASE CASTING AND ADJUSTMENT RING. 2. TRACER WIRE REQUIRED ON ALL SANITARY SEWER MAINS. TRACER WIRE REQUIRED ON ALL SANITARY SEWER MAINS. 3. CONCRETE COLLAR SHALL BE CIRCULAR LAYOUT. PAVEMENT AND BASE SHALL BE CUT OUT CONCRETE COLLAR SHALL BE CIRCULAR LAYOUT. PAVEMENT AND BASE SHALL BE CUT OUT WITH ROTATING CUTTING DEVICE 4. FINISH CONCRETE EDGE WITH 1/4" RADIUS. SEAL JOINT BETWEEN PAVEMENT AND COLLAR. FINISH CONCRETE EDGE WITH 1/4" RADIUS. SEAL JOINT BETWEEN PAVEMENT AND COLLAR. 5. MAINTAIN 3.5" COVER ON REINFORCEMENT.MAINTAIN 3.5" COVER ON REINFORCEMENT.
AutoCAD SHX Text
WATER STOP STRIP
AutoCAD SHX Text
6" MIN.
AutoCAD SHX Text
PVC PIPE ADJUSTMENT RING ASTM D-3034 SDR 35
AutoCAD SHX Text
SEE INSET A
AutoCAD SHX Text
INSET A
AutoCAD SHX Text
#4 EPOXY COATED REINFORCEMENT RING (TYP)
AutoCAD SHX Text
SEALANT
AutoCAD SHX Text
SEALANT
AutoCAD SHX Text
TRACER WIRE
AutoCAD SHX Text
2
AutoCAD SHX Text
1
AutoCAD SHX Text
3
AutoCAD SHX Text
CONCRETE COLLAR
AutoCAD SHX Text
5
AutoCAD SHX Text
EDGE JOINT SEALANT (TYP)
AutoCAD SHX Text
4
AutoCAD SHX Text
ASPHALT PAVEMENT
AutoCAD SHX Text
AGGREGATE BASE
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
CONCRETE ENCASED CASTING COLLAR FOR SANITARY MH IN ROADWAY, WALKS, & DRIVES
AutoCAD SHX Text
SAN-3A
AutoCAD SHX Text
REVISED/APPROVED 04/05/2019
AutoCAD SHX Text
CITY OF DULUTH STANDARD DETAIL DEPT. OF PUBLIC WORKS AND UTILITIES
AutoCAD SHX Text
NO SCALE
Page 7: SANITARY SEWER DETAILS SAN-1 SAN-2 TYPICAL ......SANITARY SEWER DETAILS SAN-1 SANITARY CASTING DETAIL SAN-2 TYPICAL SEWER SERVICE CONNECTION SAN-2A SEWER SERVICE CONNECTION FOR CIPP
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
TOP OF CASTING = XXX.XX
AutoCAD SHX Text
NOTE: T/CAST SHALL BE .03' BELOW FINISHED GRADE.
AutoCAD SHX Text
6" MIN. BEDDING MATERIAL
AutoCAD SHX Text
SECTION AA
AutoCAD SHX Text
NOTES: REFER TO PLAN/PROFILES FOR ELEVATIONS
AutoCAD SHX Text
TRACER WIRE
AutoCAD SHX Text
F/L OUT = XXX.XX
AutoCAD SHX Text
F/L IN = XXX.XX
AutoCAD SHX Text
45° PVC BEND
AutoCAD SHX Text
8" PVC, LENGTH AS REQUIRED
AutoCAD SHX Text
STAINLESS STEEL STRAP 4" O.C. " MINIMUM WIDTH (TYP)34" MINIMUM WIDTH (TYP)
AutoCAD SHX Text
F/L = XXX.XX
AutoCAD SHX Text
PVC TEE = 8" 8" 8"
AutoCAD SHX Text
CUT OFF "TEE" AS SHOWN AND REMOVE
AutoCAD SHX Text
8" PVC
AutoCAD SHX Text
STAINLESS STEEL STRAP 4' O.C. 34" MINIMUM WIDTH (TYP)
AutoCAD SHX Text
MH WALL (48" DIAMETER)
AutoCAD SHX Text
8" PVC
AutoCAD SHX Text
38" X 1-1/2" STAINLESS STEEL EXPANSION BOLT (TYP)
AutoCAD SHX Text
INTEGRAL BASE
AutoCAD SHX Text
SEE DETAIL SAN-3 AND SAN 3-A
AutoCAD SHX Text
CONSTRUCT INSIDE DROP STRUCTURE
AutoCAD SHX Text
SAN-4
AutoCAD SHX Text
REVISED/APPROVED 04/05/2019
AutoCAD SHX Text
CITY OF DULUTH STANDARD DETAIL DEPT. OF PUBLIC WORKS AND UTILITIES
AutoCAD SHX Text
NO SCALE
Page 8: SANITARY SEWER DETAILS SAN-1 SAN-2 TYPICAL ......SANITARY SEWER DETAILS SAN-1 SANITARY CASTING DETAIL SAN-2 TYPICAL SEWER SERVICE CONNECTION SAN-2A SEWER SERVICE CONNECTION FOR CIPP
AutoCAD SHX Text
L
AutoCAD SHX Text
P
AutoCAD SHX Text
NOTES : : 1. #12 GAUGE GREEN INSULATED COPPER TRACER WIRE SHALL BE INSTALLED WITH THE NON-CONDUCTIVE SERVICE PIPE. TRACER WIRE #12 GAUGE GREEN INSULATED COPPER TRACER WIRE SHALL BE INSTALLED WITH THE NON-CONDUCTIVE SERVICE PIPE. TRACER WIRE INSTALLATION REQUIRES ACCESS POINTS AT LEAST EVERY 300 FEET. 2. THE TRACER WIRE SHALL REMAIN CONTINUOUS TO THE GREATEST EXTENT POSSIBLE. SPLICES IN THE TRACER WIRE SHOULD BE THE TRACER WIRE SHALL REMAIN CONTINUOUS TO THE GREATEST EXTENT POSSIBLE. SPLICES IN THE TRACER WIRE SHOULD BE MADE WITH SPLIT BOLT CONNECTORS. WIRE NUTS SHALL NOT BE USED. A WATER-PROOF CONNECTION IS NECESSARY TO PREVENT CORROSION. 3. TRACER WIRE SHALL RUN FROM THE WYE AND TERMINATE IN A FLUSH MOUNTED TRACER BOX WITH A GREEN CAST IRON TOP. TRACER WIRE SHALL RUN FROM THE WYE AND TERMINATE IN A FLUSH MOUNTED TRACER BOX WITH A GREEN CAST IRON TOP.
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
L
AutoCAD SHX Text
P
AutoCAD SHX Text
CONTRACTOR SUPPLIED MAGNETIZED TRACER BOX WITH GREEN TOP OVER 1 " I.D. BLK IRON PIPE. 12" I.D. BLK IRON PIPE. WIRE CONNECTED TO TRACER BOX TERMINAL
AutoCAD SHX Text
2" I.D. BLK IRON PIPE BOTTOM SECTION SCREWED ONTO 2" X 1 " I.D. REDUCING BUSHING SUPPLIED BY CITY AT 12" I.D. REDUCING BUSHING SUPPLIED BY CITY AT GARFIELD SHOP AND INSTALLED BY CONTRACTOR. (INCIDENTAL)
AutoCAD SHX Text
BUTT FUSE REDUCER AS NECESSARY TO MATCH LATERAL DIAMETER
AutoCAD SHX Text
BUTT FUSE WYE
AutoCAD SHX Text
HDPE FORCE MAIN
AutoCAD SHX Text
TRACER WIRE
AutoCAD SHX Text
HDPE LATERAL SERVICE
AutoCAD SHX Text
TRACER WIRE RUN ALONG OUTSIDE OF STANDPIPE
AutoCAD SHX Text
LEAVE SLACK IN WIRE
AutoCAD SHX Text
CONCRETE BLOCK
AutoCAD SHX Text
SPEC. NO 3149.2H COURSE FILTER AGGREGATE
AutoCAD SHX Text
FROM HOME
AutoCAD SHX Text
FUTURE HDPE SEWER SERVICE BY OWNER
AutoCAD SHX Text
CURB BOX
AutoCAD SHX Text
BUTT FUSE OR SOCKET FUSE REDUCER AS NECESSARY TO MATCH LATERAL DIAMETER
AutoCAD SHX Text
TRACER WIRE INSTALLED PER STANDARD SPECIFICATIONS
AutoCAD SHX Text
NOTE: INSTALL 1 FT. NIPPLE AND CAP UNLESS HOUSE SERVICE IS IN PLACE (INCIDENTAL)
AutoCAD SHX Text
BUTT FUSE WYE
AutoCAD SHX Text
HDPE FORCE MAIN
AutoCAD SHX Text
HDPE TO FLARE SWIVEL
AutoCAD SHX Text
HDPE SANITARY SEWER PRESSURE LATERAL CONNECTION
AutoCAD SHX Text
SAN-5
AutoCAD SHX Text
REVISED/APPROVED 04/05/2019
AutoCAD SHX Text
CITY OF DULUTH STANDARD DETAIL DEPT. OF PUBLIC WORKS AND UTILITIES
AutoCAD SHX Text
NO SCALE
Page 9: SANITARY SEWER DETAILS SAN-1 SAN-2 TYPICAL ......SANITARY SEWER DETAILS SAN-1 SANITARY CASTING DETAIL SAN-2 TYPICAL SEWER SERVICE CONNECTION SAN-2A SEWER SERVICE CONNECTION FOR CIPP
AutoCAD SHX Text
HDPE FORCE MAIN
AutoCAD SHX Text
6" MIN. BEDDING MATERIAL
AutoCAD SHX Text
GRAVITY SEWER
AutoCAD SHX Text
ALL POURED IN PLACE CONCRETE SHALL BE MIX NUMBER 3Y43
AutoCAD SHX Text
GRAVITY SEWER, REFER TO PLAN/PROFILE FOR SIZE
AutoCAD SHX Text
FORCE MAIN, REFER TO PLAN/PROFILE FOR SIZE
AutoCAD SHX Text
NOTE: ALL CONCRETE SURFACES INSIDE OF MANHOLES TO BE COATED WITH SHERWIN-WILLIAMS TAR-GUARD COAL TAR EPOXY OR EQUAL IN ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS.
AutoCAD SHX Text
TRACER WIRE
AutoCAD SHX Text
CORE DRILL AND INSTALL MODULAR RUBBER SEAL
AutoCAD SHX Text
TAPER INVERT FROM FORCEMAIN DIAMETER TO GRAVITY SEWER DIAMETER. 6" TO 2' DROP ALLOWABLE. REFER TO PLAN/PROFILE FOR ELEVATION.
AutoCAD SHX Text
PRECAST MANHOLE SEE DETAIL SAN-11
AutoCAD SHX Text
TAPER INVERT FROM FORCEMAIN DIAMETER TO GRAVITY SEWER DIAMETER. 6" TO 2' DROP ALLOWABLE. REFER TO PLAN/PROFILE FOR ELEVATION.
AutoCAD SHX Text
INTEGRAL BASE
AutoCAD SHX Text
TRACER WIRE
AutoCAD SHX Text
SEE DETAIL SAN-3 AND SAN-3A
AutoCAD SHX Text
HDPE FORCEMAIN TO GRAVITY MAIN MANHOLE
AutoCAD SHX Text
SAN-6
AutoCAD SHX Text
REVISED/APPROVED 01/08/2016
AutoCAD SHX Text
CITY OF DULUTH STANDARD DETAIL DEPT. OF PUBLIC WORKS AND UTILITIES
AutoCAD SHX Text
NO SCALE
Page 10: SANITARY SEWER DETAILS SAN-1 SAN-2 TYPICAL ......SANITARY SEWER DETAILS SAN-1 SANITARY CASTING DETAIL SAN-2 TYPICAL SEWER SERVICE CONNECTION SAN-2A SEWER SERVICE CONNECTION FOR CIPP
AutoCAD SHX Text
FORCE MAIN
AutoCAD SHX Text
FORCE MAIN
AutoCAD SHX Text
INCIDENTAL TO MH CONSTRUCTION
AutoCAD SHX Text
ALL POURED IN PLACE CONCRETE SHALL BE MIX NUMBER 3Y43
AutoCAD SHX Text
HDPE FORCE MAIN
AutoCAD SHX Text
HDPE FORCE MAIN
AutoCAD SHX Text
6" MIN. BEDDING MATERIAL
AutoCAD SHX Text
1 " X 1 " S.S. SUPPORT BRACKETS WITH 12" X 1 " S.S. SUPPORT BRACKETS WITH 12" S.S. SUPPORT BRACKETS WITH S.S. BAND OR APPROVED EQUAL (ALL PARTS AND HARDWARE TO BE STAINLESS STEEL
AutoCAD SHX Text
AIR VACUUM RELEASE VALVE
AutoCAD SHX Text
INTEGRAL BASE
AutoCAD SHX Text
CONCRETE SUPPORT, MIN. 8" HIGH
AutoCAD SHX Text
CORE DRILL AND INSTALL MODULAR RUBBER SEAL
AutoCAD SHX Text
TRACER WIRE
AutoCAD SHX Text
1 " X 1 " S.S. SUPPORT 12" X 1 " S.S. SUPPORT 12" S.S. SUPPORT BRACKET WITH S.S. BAND OR APPROVED EQUAL
AutoCAD SHX Text
ELECTROFUSION SERVICE SADDLE WITH 2" BRASS INSERT
AutoCAD SHX Text
NOTE: MANHOLE TO MEET ALL REQUIREMENTS OF SAN-11
AutoCAD SHX Text
NOTE: TOP OF CASTING SHALL BE .03' BELOW FINISHED GRADE
AutoCAD SHX Text
SEE DETAIL SAN-3 AND SAN-3A
AutoCAD SHX Text
6" POLYSTYRENE INSULATION BOARD (DOW STYROFOAM HI 40, CERTIFOAM 40, OR EQUIVALENT)
AutoCAD SHX Text
12" TREATED PLYWOOD SUPPORTED BY 1" S.S. ANGLE IRON W/ STAINLESS LAG BOLTS
AutoCAD SHX Text
PRECAST MANHOLE SEE DETAIL SAN-11
AutoCAD SHX Text
TRACER WIRE
AutoCAD SHX Text
AIR VACUUM RELEASE VALVE APCO MODEL 443, VAL-MATIC 801WA, OR APPROVED EQUAL
AutoCAD SHX Text
2" GALVANIZED IRON PIPE
AutoCAD SHX Text
2" PE FULLY PORTED THREADED BALL VALVE
AutoCAD SHX Text
8' X 8' X 3" POLYSTYRENE INSULATION
AutoCAD SHX Text
3" X 12" X 4' INSULATION STRIPS
AutoCAD SHX Text
MAGNETIZED TRACER WIRE BOX
AutoCAD SHX Text
MAGNETIZED TRACER WIRE BOX
AutoCAD SHX Text
AIR-RELEASE MANHOLE
AutoCAD SHX Text
SAN-7
AutoCAD SHX Text
REVISED/APPROVED 01/08/2019
AutoCAD SHX Text
CITY OF DULUTH STANDARD DETAIL DEPT. OF PUBLIC WORKS AND UTILITIES
AutoCAD SHX Text
NO SCALE
Page 11: SANITARY SEWER DETAILS SAN-1 SAN-2 TYPICAL ......SANITARY SEWER DETAILS SAN-1 SANITARY CASTING DETAIL SAN-2 TYPICAL SEWER SERVICE CONNECTION SAN-2A SEWER SERVICE CONNECTION FOR CIPP
AutoCAD SHX Text
FORCE MAIN
AutoCAD SHX Text
HDPE FORCE MAIN
AutoCAD SHX Text
6" MIN. BEDDING MATERIAL
AutoCAD SHX Text
HDPE FORCE MAIN
AutoCAD SHX Text
ALL POURED IN PLACE CONCRETE SHALL BE MIX NUMBER 3Y43
AutoCAD SHX Text
FORCE MAIN
AutoCAD SHX Text
1 " X " S.S. SUPPORT BRACKETS WITH S.S. 12" X " S.S. SUPPORT BRACKETS WITH S.S. 112" S.S. SUPPORT BRACKETS WITH S.S. BAND OR APPROVED EQUAL (ALL PARTS AND HARDWARE TO BE STAINLESS STEEL
AutoCAD SHX Text
NOTE: TOP OF CASTING SHALL BE .03' BELOW FINISHED GRADE
AutoCAD SHX Text
SEE DETAIL SAN-3 AND SAN-3A
AutoCAD SHX Text
MAGNETIZED TRACER WIRE BOX
AutoCAD SHX Text
2" CAMLOCK COUPLER 3" BELOW PLYWOOD
AutoCAD SHX Text
1 " X 1 " S.S. SUPPORT BRACKET WITH 12" X 1 " S.S. SUPPORT BRACKET WITH 12" S.S. SUPPORT BRACKET WITH S.S. BAND OR APPROVED EQUAL BELOW VALVE AND EVERY 4' (ALL PARTS AND HARDWARE TO BE STAINLESS STEEL)
AutoCAD SHX Text
2" PE FULLY PORTED THREADED BALL VALVE
AutoCAD SHX Text
TRACER WIRE
AutoCAD SHX Text
CORE DRILL AND INSTALL MODULAR RUBBER SEAL
AutoCAD SHX Text
INTEGRAL BASE
AutoCAD SHX Text
CONCRETE SUPPORT MIN. 8" HIGH
AutoCAD SHX Text
PE WYE
AutoCAD SHX Text
PE 45° BEND
AutoCAD SHX Text
PRECAST MANHOLE SEE DETAIL SAN-11
AutoCAD SHX Text
TRACER WIRE
AutoCAD SHX Text
INCIDENTAL TO MH CONSTRUCTION
AutoCAD SHX Text
6" POLYSTYRENE INSULATION BOARD (DOW STYROFOAM HI 40, CERTIFOAM 40, OR EQUIVALENT)
AutoCAD SHX Text
12" TREATED PLYWOOD SUPPORTED BY 1" S.S. ANGLE IRON W/ STAINLESS LAG BOLTS
AutoCAD SHX Text
CLEANOUT
AutoCAD SHX Text
3" THICK SPRAY ON CLOSED SELL FOAM INSULATION
AutoCAD SHX Text
3" THICK SPRAY ON CLOSED-CELL FOAM INSULATION
AutoCAD SHX Text
CLEANOUT MANHOLE
AutoCAD SHX Text
SAN-8
AutoCAD SHX Text
REVISED/APPROVED 04/05/2019
AutoCAD SHX Text
CITY OF DULUTH STANDARD DETAIL DEPT. OF PUBLIC WORKS AND UTILITIES
AutoCAD SHX Text
NO SCALE
Page 12: SANITARY SEWER DETAILS SAN-1 SAN-2 TYPICAL ......SANITARY SEWER DETAILS SAN-1 SANITARY CASTING DETAIL SAN-2 TYPICAL SEWER SERVICE CONNECTION SAN-2A SEWER SERVICE CONNECTION FOR CIPP
AutoCAD SHX Text
FORCE MAIN
AutoCAD SHX Text
HDPE FORCE MAIN
AutoCAD SHX Text
FORCE MAIN
AutoCAD SHX Text
THESE ITEMS ARE INCIDENTAL TO HANDHOLE CONSTRUCTION AND SHALL BE CUSTOM FIT TO ACHIEVE MANHOLE INSULATION AND MAINTAIN ACCESSIBILITY.
AutoCAD SHX Text
1-1/2" X 1-1/2" S.S. SUPPORT BRACKETS WITH S.S. BAND OR APPROVED EQUAL (ALL PARTS AND HARDWARE TO BE STAINLESS STEEL
AutoCAD SHX Text
NOTE: TOP OF CASTING SHALL BE .03' BELOW FINISHED GRADE
AutoCAD SHX Text
SEE DETAIL SAN-3/SAN-3A
AutoCAD SHX Text
MAGNETIZED TRACER WIRE BOX
AutoCAD SHX Text
PE PIPE END THREADED PLUG 3" BELOW PLYWOOD
AutoCAD SHX Text
1-1/2" X 1-1/2" S.S. SUPPORT BRACKET WITH S.S. BAND OR APPROVED EQUAL BELOW VALVE (ALL PARTS AND HARDWARE TO BE STAINLESS STEEL)
AutoCAD SHX Text
2" PE FULLY PORTED THREADED BALL VALVE
AutoCAD SHX Text
TRACER WIRE
AutoCAD SHX Text
6" POLYSTYRENE INSULATION BOARD (DOW STYROFOAM HI 40, CERTIFOAM 40, OR EQUIVALENT)
AutoCAD SHX Text
12" TREATED PLYWOOD SUPPORTED BY 1" S.S. ANGLE IRON W/ STAINLESS LAG BOLTS
AutoCAD SHX Text
CLEANOUT (DEAD END)
AutoCAD SHX Text
STRUCTURE COATED WITH 3" THICK SPRAY ON CLOSED-CELL FOAM INSULATION
AutoCAD SHX Text
3" THICK CLOSED-CELL FOAM INSULATION AROUND STRUCTURE
AutoCAD SHX Text
48" DEEP 30" DIAMETER PRECAST MANHOLE (MNDOT STANDARD PLATE 4005M) DESIGN "F" W/0 CONCRETE BASE
AutoCAD SHX Text
GRANULAR BACKFILL
AutoCAD SHX Text
2" HDPE SANITARY FORCEMAIN
AutoCAD SHX Text
DEAD END CLEANOUT HAND HOLE
AutoCAD SHX Text
SAN-8A
AutoCAD SHX Text
REVISED/APPROVED 04/05/2019
AutoCAD SHX Text
CITY OF DULUTH STANDARD DETAIL DEPT. OF PUBLIC WORKS AND UTILITIES
AutoCAD SHX Text
NO SCALE
Page 13: SANITARY SEWER DETAILS SAN-1 SAN-2 TYPICAL ......SANITARY SEWER DETAILS SAN-1 SANITARY CASTING DETAIL SAN-2 TYPICAL SEWER SERVICE CONNECTION SAN-2A SEWER SERVICE CONNECTION FOR CIPP
AutoCAD SHX Text
DESCRIPTION 1. PLASTIC INJECTION MOLDED ADJUSTMENT RING PLASTIC INJECTION MOLDED ADJUSTMENT RING 2. MOLDED FROM HIGH DENSITY POLYETHYLENE AS DEFINED IN ASTM SPECIFICATION D1248 MOLDED FROM HIGH DENSITY POLYETHYLENE AS DEFINED IN ASTM SPECIFICATION D1248 SPECIFICATION D1248 3. ACTUAL RESIN PROPERTIES WILL VARY ALLOWING FOR THE UTILIZATION OF A MAXIMUM PERCENT OF RECYCLED MATERIAL ACTUAL RESIN PROPERTIES WILL VARY ALLOWING FOR THE UTILIZATION OF A MAXIMUM PERCENT OF RECYCLED MATERIAL 4. THE PERCENT OF POST CONSUMER WASTE TO INDUSTRIAL WASTE WILL VARY WITH AVAILABILITY AND PROPERTY RETENTION NEEDS THE PERCENT OF POST CONSUMER WASTE TO INDUSTRIAL WASTE WILL VARY WITH AVAILABILITY AND PROPERTY RETENTION NEEDS 5. COLOR, SHADE AND UNIFORMITY WILL VARY WITH THE MIX OF THE POST CONSUMER AND INDUSTRIAL WASTE MATERIALS COLOR, SHADE AND UNIFORMITY WILL VARY WITH THE MIX OF THE POST CONSUMER AND INDUSTRIAL WASTE MATERIALS 6. DIMENSIONS SHOWN ARE NOMINAL - ACTUAL SIZE WILL VARY WITHIN ALLOWABLE TOLERANCE AND REQUIRED FITDIMENSIONS SHOWN ARE NOMINAL - ACTUAL SIZE WILL VARY WITHIN ALLOWABLE TOLERANCE AND REQUIRED FIT
AutoCAD SHX Text
DIMENSION SCHEDULE
AutoCAD SHX Text
CONE SIZE
AutoCAD SHX Text
DIMENSION A
AutoCAD SHX Text
DIMENSION B
AutoCAD SHX Text
DIMENSION C
AutoCAD SHX Text
DIMENSION D
AutoCAD SHX Text
DIMENSION H1
AutoCAD SHX Text
27.00
AutoCAD SHX Text
26.75
AutoCAD SHX Text
36.50
AutoCAD SHX Text
5.00
AutoCAD SHX Text
26.25
AutoCAD SHX Text
1.20, 1.50, 2.00, 4.00
AutoCAD SHX Text
POLYETHYLENE MH ADJUSTING RING - FLAT
AutoCAD SHX Text
SAN-9
AutoCAD SHX Text
REVISED/APPROVED 02/01/2013
AutoCAD SHX Text
CITY OF DULUTH STANDARD DETAIL DEPT. OF PUBLIC WORKS AND UTILITIES
AutoCAD SHX Text
NO SCALE
Page 14: SANITARY SEWER DETAILS SAN-1 SAN-2 TYPICAL ......SANITARY SEWER DETAILS SAN-1 SANITARY CASTING DETAIL SAN-2 TYPICAL SEWER SERVICE CONNECTION SAN-2A SEWER SERVICE CONNECTION FOR CIPP
AutoCAD SHX Text
DESCRIPTION 1. PLASTIC INJECTION MOLDED ADJUSTMENT RING PLASTIC INJECTION MOLDED ADJUSTMENT RING 2. MOLDED FROM HIGH DENSITY POLYETHYLENE AS DEFINED IN ASTM SPECIFICATION D1248 MOLDED FROM HIGH DENSITY POLYETHYLENE AS DEFINED IN ASTM SPECIFICATION D1248 SPECIFICATION D1248 3. ACTUAL RESIN PROPERTIES WILL VARY ALLOWING FOR THE UTILIZATION OF A MAXIMUM PERCENT OF RECYCLED MATERIAL ACTUAL RESIN PROPERTIES WILL VARY ALLOWING FOR THE UTILIZATION OF A MAXIMUM PERCENT OF RECYCLED MATERIAL 4. THE PERCENT OF POST CONSUMER WASTE TO INDUSTRIAL WASTE WILL VARY WITH AVAILABILITY AND PROPERTY RETENTION NEEDS THE PERCENT OF POST CONSUMER WASTE TO INDUSTRIAL WASTE WILL VARY WITH AVAILABILITY AND PROPERTY RETENTION NEEDS 5. COLOR, SHADE AND UNIFORMITY WILL VARY WITH THE MIX OF THE POST CONSUMER AND INDUSTRIAL WASTE MATERIALS COLOR, SHADE AND UNIFORMITY WILL VARY WITH THE MIX OF THE POST CONSUMER AND INDUSTRIAL WASTE MATERIALS 6. DIMENSIONS SHOWN ARE NOMINAL - ACTUAL SIZE WILL VARY WITHIN ALLOWABLE TOLERANCE AND REQUIRED FITDIMENSIONS SHOWN ARE NOMINAL - ACTUAL SIZE WILL VARY WITHIN ALLOWABLE TOLERANCE AND REQUIRED FIT
AutoCAD SHX Text
DIMENSION SCHEDULE
AutoCAD SHX Text
CONE SIZE
AutoCAD SHX Text
DIMENSION A
AutoCAD SHX Text
DIMENSION B
AutoCAD SHX Text
DIMENSION C
AutoCAD SHX Text
DIMENSION D
AutoCAD SHX Text
DIMENSION H1-H2
AutoCAD SHX Text
27.00
AutoCAD SHX Text
26.75
AutoCAD SHX Text
36.50
AutoCAD SHX Text
5.00
AutoCAD SHX Text
26.25
AutoCAD SHX Text
0.75 - 1.50
AutoCAD SHX Text
POLYETHYLENE MH ADJUSTING RING - WEDGE
AutoCAD SHX Text
SAN-10
AutoCAD SHX Text
REVISED/APPROVED 02/01/2013
AutoCAD SHX Text
CITY OF DULUTH STANDARD DETAIL DEPT. OF PUBLIC WORKS AND UTILITIES
AutoCAD SHX Text
NO SCALE
Page 15: SANITARY SEWER DETAILS SAN-1 SAN-2 TYPICAL ......SANITARY SEWER DETAILS SAN-1 SANITARY CASTING DETAIL SAN-2 TYPICAL SEWER SERVICE CONNECTION SAN-2A SEWER SERVICE CONNECTION FOR CIPP
AutoCAD SHX Text
NOTES 1. SANITARY MANHOLES SHALL NOT HAVE STEPS. 2. ALL SANITARY MANHOLES SHALL BE VACUUM TESTED. 3. ALL SANITARY MANHOLES SHALL BE WATERTIGHT. ANY OBSERVABLE WATER SEEPAGE THROUGH THE END OF THE WARRANTY PERIOD SHALL BE CAUSE TO REJECT MANHOLES. 4. AN INSIDE DROP IS REQUIRED PER DETAIL SAN-4 ANYTIME THE DROP IS GREATER THAN 2.0'.
AutoCAD SHX Text
PIPE SLEEVE DETAIL 1. ALL PIPE SLEEVES MUST BE WATER TIGHT
AutoCAD SHX Text
REFER TO STANDARD DETAIL SAN-1 FOR CASTINGS REQUIRED. USE ADJUSTING RINGS WHERE NECESSARY. REFER TO DETAILS SAN-3, SAN-3A, SAN-9 & SAN-10.
AutoCAD SHX Text
6" MAXIMUM ADJUSTMENT ALLOWED
AutoCAD SHX Text
TRACER WIRE TO BE CONTINUOUS
AutoCAD SHX Text
SEE DETAIL SAN-3 AND SAN-3A
AutoCAD SHX Text
GASKET (MNDOT SPEC. 3726 TYPE B) OR APPROVED EQUAL
AutoCAD SHX Text
REINFORCING SHALL BE A MINIMUM OF A SINGLE LINE WIRE FABRIC HAVING AN AREA OF NOT LESS THAN 0.12 SQ. IN. PER FT. OF HEIGHT
AutoCAD SHX Text
TRACER WIRE
AutoCAD SHX Text
3" SLOPE FROM TROUGH TO WALL
AutoCAD SHX Text
CLASS A CONCRETE
AutoCAD SHX Text
6" MIN. BEDDING MATERIAL
AutoCAD SHX Text
INTEGRAL BASE
AutoCAD SHX Text
FORMED CONCRETE TROUGH TO MATCH PIPE INVERTS
AutoCAD SHX Text
STAINLESS STEEL STRAP WITH DRAW BOLTS AND NUTS OR WORM DRIVE SCREW
AutoCAD SHX Text
SEWER PIPE
AutoCAD SHX Text
INTERNAL EXPANDING LOCKING BAND (NON-MAGNETIC CORROSION RESISTANT STEEL)
AutoCAD SHX Text
PRECAST MECHANICAL JOINT SEWER MANHOLE
AutoCAD SHX Text
SAN-11
AutoCAD SHX Text
REVISED/APPROVED 01/08/2016
AutoCAD SHX Text
CITY OF DULUTH STANDARD DETAIL DEPT. OF PUBLIC WORKS AND UTILITIES
AutoCAD SHX Text
NO SCALE