Date received: 16/07/18
Date of issue: 19/09/18
Report consists of 9 test reports.
Sample name: Armchair Specto Xl
SAMPLE N° 255152
List performed tests: 1. Outdoor furniture - General safety requirements EN 581-1:2017 2. Seat and back static load test EN 1728:2012+AC:2013 3. Seat and back fatigue test EN 1728:2012+AC:2013 4. Arm downwards static load test EN1728:2012+AC:2013 5. Arm fatigue test EN 1728:2012+AC:2013 6. Leg forward static load test EN 1728:2012+AC:2013 7. Leg sideways static load test EN 1728:2012+AC:2013 8. Seat impact test EN 1728:2012+AC:2013 9. Stability - EN 1022:2005
SAVAS PLASTIK SAN. VE. TIC. A.S.BEYSAN SAN. SIT. BIRLIK CAD. NO: 18-BEY.34524 ISTANBUL ()TR - TURKEY
The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.
Page 1 of 2
This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.
Managing Director Dr. Andrea Giavon
Defects before testing: None
Overall dimensions: 620 x 580 x 820 (h) mm
Tests, certification and research
CATAS S.p.A. via Antica, 24/3 33048 San Giovanni al Natisone (UD) +39 0432 747211 - [email protected] www.catas.com
Testing site: via Braide Matte, 4 33048 San Giovanni al Natisone (UD) tel. +39 0432 747211 [email protected]
Date of issue: 19/09/18
Sample name: Armchair Specto Xl
SAMPLE N° 255152
Page 2 of 2
The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.
Side view Rear view
Bottom view
Sample weight: Not determined
Tests, certification and research
CATAS S.p.A. via Antica, 24/3 33048 San Giovanni al Natisone (UD) +39 0432 747211 - [email protected] www.catas.com
Testing site: via Braide Matte, 4 33048 San Giovanni al Natisone (UD) tel. +39 0432 747211 [email protected]
TEST REPORT
255152 / 1Date received: 16/07/18Date of test: 21/08/18Date of issue: 19/09/18Sample name: Armchair Specto Xl
Outdoor furniture - General safety requirements EN 581-1:2017
SAVAS PLASTIK SAN. VE. TIC. A.S.BEYSAN SAN. SIT. BIRLIK CAD. NO: 18-BEY.34524 ISTANBULTR - TURKEY
Tests, certification and research
CATAS S.p.A. via Antica, 24/3 33048 San Giovanni al Natisone (UD) +39 0432 747211 - [email protected] www.catas.com
Testing site: via Braide Matte, 4 33048 San Giovanni al Natisone (UD) tel. +39 0432 747211 [email protected]
5.1 General:Observed RemarksRequirement
Edges of seat, back rest and arm rests rounded andchamfered Yes None
All other parts: free from burrs, sharp edges andsharp points. Yes None
Movable and adjustable parts designed so thatinjuries and inadvertent operation are avoided Yes None
Any load bearing part of forniture not come looseunintentionally Yes None
Lubricated parts are protected Yes None
5.2 Tubular components:Observed RemarksRequirement
Absence of tubular components with diameter> 7 mm and < 12 mm with a depth > 10 mm. No Tubolar not present
Tubulars in contact with the floor are closed. Holesin them are allowed as long as they are < 7 mm or> 12 mm
Yes None
5.3 Shear and squeeze points:Observed RemarksRequirement
Shear and squeeze points that are created onlyduring adjusting and folding away are acceptableif the user has the control of his/her movements.
Yes None
Absence of shear and squeeze points, createdby parts operated by powered mechanism. No Mechanism not present
Absence of shear and squeeze points, createdby loads applied during normal use. Yes None
Conformity to requirements of clause 5 of standard EN 581-1:2017: YES
pag. 1/1
The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.
This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.
Managing Director Dr. Andrea Giavon
TEST REPORT
255152 / 2Date received: 16/07/18Date of test: 21/08/18Date of issue: 19/09/18Sample name: Armchair Specto Xl
Seat and back static load test EN 1728:2012+AC:2013
SAVAS PLASTIK SAN. VE. TIC. A.S.BEYSAN SAN. SIT. BIRLIK CAD. NO: 18-BEY.34524 ISTANBULTR - TURKEY
Tests, certification and research
CATAS S.p.A. via Antica, 24/3 33048 San Giovanni al Natisone (UD) +39 0432 747211 - [email protected] www.catas.com
Testing site: via Braide Matte, 4 33048 San Giovanni al Natisone (UD) tel. +39 0432 747211 [email protected]
Seat and back static load test, clause 6.4
Back forceN
Numberof cycles Remarks
EN 16139
SI NO
EN 12520
SI NO IKEA IOS-PRF-0040 SI NOTest results:
a) Rotture di componenti o giunzioni a) Rotture di componenti o giunzioniSeat load
N
SI NO SI
Stabilità
NO
2.000 450 10 x 10 s No defects b) Allentamenti di giunzioni b) Nessun componente rigido è allentato Rotture di componenti o giunzioni
2000 450 1 x 30 min No defects c) No elemento strutturale importante notevolm. def. c) Funzioni inalterate dopo rimoz. carichi Rotture di componenti strutturali
d) Funzioni inalterate dopo rimoz. carichiNote :According to EN 1728:2012, back force has been reduced from 560 N to 450 N to avoid tipping.
Numberof cycles Remarks
d) stabilità Allentamenti di giunzioni
Deformazioni o rotture che pregiudicano utilizzo campioneApparecchiatura Apparecchiatura
Seat front edge static load, clause 6.5Danni su movimeto di parti meccaniche
EN 581-2 EN 12727 Funzioni inalterate dopo rimoz. carichi
Seat loadN Rotture di componenti o giunzioni Rotture di componenti o giunzioni Apparecchiatura
c
v1.300 10 No defects Allentamenti di giunzioni v Allentamenti di giunzioni
Funzioni inalterate dopo rimoz. carichiNote:
Funzioni inalterateRispetto requisiti EN 581-1 c Rispetto requisiti EN 12727, punto 5.1 e 5.2
The test has been carried out according to table 2 of EN 581-2:2015, contract level. Stabilità c
ApparecchiaturaApparecchiatura 1827
pag. 1/1
The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.
This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.
Managing Director Dr. Andrea Giavon
TEST REPORT
255152 / 3Date received: 16/07/18Date of test: 21/08/18Date of issue: 19/09/18Sample name: Armchair Specto Xl
Seat and back fatigue test EN 1728:2012+AC:2013
SAVAS PLASTIK SAN. VE. TIC. A.S.BEYSAN SAN. SIT. BIRLIK CAD. NO: 18-BEY.34524 ISTANBULTR - TURKEY
Tests, certification and research
CATAS S.p.A. via Antica, 24/3 33048 San Giovanni al Natisone (UD) +39 0432 747211 - [email protected] www.catas.com
Testing site: via Braide Matte, 4 33048 San Giovanni al Natisone (UD) tel. +39 0432 747211 [email protected]
Seat and back fatigue test, clause 6.17
Back forceN
Numberof cycles Remarks
EN 16139
1868
SI NO
EN 12520
SI NOTest results: a) Rotture di componenti o giunzioni a) Rotture di componenti o giunzioni
SI NO SI NO
b) Allentamenti di giunzioni
Seat forceN
b) Nessun componente rigido è allentato
c) No elemento strutturale importante notevolm. def. c) Funzioni inalterate dopo rimoz. carichi
1.000 300 50.000 No defectsd) Funzioni inalterate dopo rimoz. carichi d) stabilità
Note:Apparecchiatura ApparecchiaturaEN 581-2 EN 12727
According to EN 1728:2012, back force has been reduced from 333 N to 300 N to avoid tipping.Rotture di componenti o giunzioni Rotture di componenti o giunzioni
The test has been carried out according to table 2 of EN 581-2:2015, contract level.
x
xAllentamenti di giunzioni x Allentamenti di giunzioniFunzioni inalterate dopo rimoz. carichi Funzioni inalterateRispetto requisiti EN 581-1 x Rispetto requisiti EN 12727, punto 5.1 e 5.2Stabilità x
ApparecchiaturaApparecchiatura
pag. 1/1
The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.
This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.
Managing Director Dr. Andrea Giavon
TEST REPORT
255152 / 4Date received: 16/07/18Date of test: 10/09/18Date of issue: 19/09/18Sample name: Armchair Specto Xl
Arm downwards static load test EN1728:2012+AC:2013
SAVAS PLASTIK SAN. VE. TIC. A.S.BEYSAN SAN. SIT. BIRLIK CAD. NO: 18-BEY.34524 ISTANBULTR - TURKEY
Tests, certification and research
CATAS S.p.A. via Antica, 24/3 33048 San Giovanni al Natisone (UD) +39 0432 747211 - [email protected] www.catas.com
Testing site: via Braide Matte, 4 33048 San Giovanni al Natisone (UD) tel. +39 0432 747211 [email protected]
Arm downwards static load test clause 6.11
Number ofapplications Remarks
EN 16139
SI NO
EN 12520
SI NO
IKEA IOS-PRF-0040 SI NOStabilità
Test results:a) Rotture di componenti o giunzioni a) Rotture di componenti o giunzioni
Rotture di componenti o giunzioni
SI NO SI
Rotture di componenti strutturali
NO
b) Allentamenti di giunzioni b) Nessun componente rigido è allentato Allentamenti di giunzionic) No elemento strutturale importante notevolm. def.
Verticalforce
N
c) Funzioni inalterate dopo rimoz. carichi Deformazioni o rotture che pregiudicano utilizzo campione
d) Funzioni inalterate dopo rimoz. carichi d) stabilità Danni su movimeto di parti meccaniche900 10 No defects Funzioni inalterate dopo rimoz. carichi
Apparecchiatura Apparecchiatura
Note:
ApparecchiaturaEN 581-2 EN 12727
Rotture di componenti o giunzioni Rotture di componenti o giunzioni
x
xThe test has been carried out according to table 2 of EN 581-2:2015, contract level. Allentamenti di giunzioni x Allentamenti di giunzioni
Funzioni inalterate dopo rimoz. carichi Funzioni inalterateRispetto requisiti EN 581-1 x Rispetto requisiti EN 12727, punto 5.1 e 5.2Stabilità c
ApparecchiaturaApparecchiatura
pag. 1/1
The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.
This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.
Managing Director Dr. Andrea Giavon
TEST REPORT
255152 / 5Date received: 16/07/18Date of test: 10/09/18Date of issue: 19/09/18Sample name: Armchair Specto Xl
Arm fatigue test EN 1728:2012+AC:2013
SAVAS PLASTIK SAN. VE. TIC. A.S.BEYSAN SAN. SIT. BIRLIK CAD. NO: 18-BEY.34524 ISTANBULTR - TURKEY
Tests, certification and research
CATAS S.p.A. via Antica, 24/3 33048 San Giovanni al Natisone (UD) +39 0432 747211 - [email protected] www.catas.com
Testing site: via Braide Matte, 4 33048 San Giovanni al Natisone (UD) tel. +39 0432 747211 [email protected]
Arm fatigue test clause 6.20
Numberof cycles Remarks
EN 16139
1796
SI NO
EN 12520
SI NOTest results: a) Rotture di componenti o giunzioni a) Rotture di componenti o giunzioni
SI NO SI NO
b) Allentamenti di giunzioniForce
on arm restN
b) Nessun componente rigido è allentato
c) No elemento strutturale importante notevolm. def. c) Funzioni inalterate dopo rimoz. carichi
400 30.000 No defectsd) Funzioni inalterate dopo rimoz. carichi d) stabilità
Note:Apparecchiatura ApparecchiaturaEN 581-2 EN 12727
The test has been carried out according to table 2 of EN 581-2:2015, contract level.Rotture di componenti o giunzioni Rotture di componenti o giunzionix
xAllentamenti di giunzioni x Allentamenti di giunzioniFunzioni inalterate dopo rimoz. carichi Funzioni inalterateRispetto requisiti EN 581-1 x Rispetto requisiti EN 12727, punto 5.1 e 5.2
Stabilità x
ApparecchiaturaApparecchiatura
pag. 1/1
The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.
This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.
Managing Director Dr. Andrea Giavon
TEST REPORT
255152 / 6Date received: 16/07/18Date of test: 12/09/18Date of issue: 19/09/18Sample name: Armchair Specto Xl
Leg forward static load test EN 1728:2012+AC:2013
SAVAS PLASTIK SAN. VE. TIC. A.S.BEYSAN SAN. SIT. BIRLIK CAD. NO: 18-BEY.34524 ISTANBULTR - TURKEY
Tests, certification and research
CATAS S.p.A. via Antica, 24/3 33048 San Giovanni al Natisone (UD) +39 0432 747211 - [email protected] www.catas.com
Testing site: via Braide Matte, 4 33048 San Giovanni al Natisone (UD) tel. +39 0432 747211 [email protected]
Leg forward static load test clause 6.15
Balancingseat force
NNumberof cycles Remarks
EN 16139
SI NO
EN 12520
SI NOIKEA IOS-PRF-0040 SI NO
Test results:a) Rotture di componenti o giunzioni a) Rotture di componenti o giunzioni
Stabilità
SI NO
Rotture di componenti o giunzionib) Allentamenti di giunzioni b) Nessun componente rigido è allentato Rotture di componenti strutturalic) No elemento strutturale importante notevolm. def.
Forwardhorizontal force
N
c) Funzioni inalterate dopo rimoz. carichi Allentamenti di giunzioni
d) Funzioni inalterate dopo rimoz. carichi d) stabilità Deformazioni o rotture che pregiudicano utilizzo campione
400 1.000 10 No defectsDanni su movimeto di parti meccaniche
Apparecchiatura Apparecchiatura
Note:
Funzioni inalterate dopo rimoz. carichiEN 581-2
ApparecchiaturaRotture di componenti o giunzioniThe test has been carried out according to table 2 of EN 581-2:2015, contract level.
x
xAllentamenti di giunzioni xFunzioni inalterate dopo rimoz. carichi
Rispetto requisiti EN 581-1x
Stabilità x
Apparecchiatura
pag. 1/1
The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.
This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.
Managing Director Dr. Andrea Giavon
TEST REPORT
255152 / 7Date received: 16/07/18Date of test: 12/09/18Date of issue: 19/09/18Sample name: Armchair Specto Xl
Leg sideways static load test EN 1728:2012+AC:2013
SAVAS PLASTIK SAN. VE. TIC. A.S.BEYSAN SAN. SIT. BIRLIK CAD. NO: 18-BEY.34524 ISTANBULTR - TURKEY
Tests, certification and research
CATAS S.p.A. via Antica, 24/3 33048 San Giovanni al Natisone (UD) +39 0432 747211 - [email protected] www.catas.com
Testing site: via Braide Matte, 4 33048 San Giovanni al Natisone (UD) tel. +39 0432 747211 [email protected]
Leg sideways static load test clause 6.16
Balancingseat force
NNumberof cycles Remarks
EN 16139
SI NO
EN 12520
SI NOIKEA IOS-PRF-0040 SI NO
Test results:a) Rotture di componenti o giunzioni a) Rotture di componenti o giunzioni
Stabilità
SI NO
Rotture di componenti o giunzionib) Allentamenti di giunzioni b) Nessun componente rigido è allentato Rotture di componenti strutturalic) No elemento strutturale importante notevolm. def.
Sidewayshorizontal force
N
c) Funzioni inalterate dopo rimoz. carichi Allentamenti di giunzioni
d) Funzioni inalterate dopo rimoz. carichi d) stabilità Deformazioni o rotture che pregiudicano utilizzo campione
300 1.000 10 No defectsDanni su movimeto di parti meccaniche
Apparecchiatura Apparecchiatura
Note:
Funzioni inalterate dopo rimoz. carichiEN 581-2
ApparecchiaturaRotture di componenti o giunzioniThe test has been carried out according to table 2 of EN 581-2:2015, contract level.
x
xAllentamenti di giunzioni xFunzioni inalterate dopo rimoz. carichi
Rispetto requisiti EN 581-1x
Stabilità x
Apparecchiatura
pag. 1/1
The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.
This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.
Managing Director Dr. Andrea Giavon
TEST REPORT
255152 / 8Date received: 16/07/18Date of test: 13/09/18Date of issue: 19/09/18Sample name: Armchair Specto Xl
Seat impact test EN 1728:2012+AC:2013
SAVAS PLASTIK SAN. VE. TIC. A.S.BEYSAN SAN. SIT. BIRLIK CAD. NO: 18-BEY.34524 ISTANBULTR - TURKEY
Tests, certification and research
CATAS S.p.A. via Antica, 24/3 33048 San Giovanni al Natisone (UD) +39 0432 747211 - [email protected] www.catas.com
Testing site: via Braide Matte, 4 33048 San Giovanni al Natisone (UD) tel. +39 0432 747211 [email protected]
Seat impact test clause 6.24
Heightof drop
mmNumberof drops Remarks
EN 16139
SI NO
EN 12520
SI NO
IKEA IOS-PRF-0040 SI NOStabilità
Test results:a) Rotture di componenti o giunzioni a) Rotture di componenti o giunzioni
Rotture di componenti o giunzioni
SI NO SI
Rotture di componenti strutturali
NO
b) Allentamenti di giunzioni b) Nessun componente rigido è allentato Allentamenti di giunzionic) No elemento strutturale importante notevolm. def.
Mass ofimpactor
kg
c) Funzioni inalterate dopo rimoz. carichi Deformazioni o rotture che pregiudicano utilizzo campione
d) Funzioni inalterate dopo rimoz. carichi d) stabilità Danni su movimeto di parti meccaniche
25 240 10 No defects Funzioni inalterate dopo rimoz. carichi
Apparecchiatura Apparecchiatura
Note:ApparecchiaturaEN 581-2 EN 12727
Rotture di componenti o giunzioni Rotture di componenti o giunzioniThe test has been carried out according to table 2 of EN 581-2:2015, contract level.
x
cAllentamenti di giunzioni c Allentamenti di giunzioniFunzioni inalterate dopo rimoz. carichi Funzioni inalterateRispetto requisiti EN 581-1 x Rispetto requisiti EN 12727, punto 5.1 e 5.2Stabilità x
ApparecchiaturaApparecchiatura
pag. 1/1
The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.
This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.
Managing Director Dr. Andrea Giavon
TEST REPORT
255152 / 9Date received: 16/07/18Date of test: 13/09/18Date of issue: 19/09/18Sample name: Armchair Specto Xl
Stability - EN 1022:2005
SAVAS PLASTIK SAN. VE. TIC. A.S.BEYSAN SAN. SIT. BIRLIK CAD. NO: 18-BEY.34524 ISTANBULTR - TURKEY
Tests, certification and research
CATAS S.p.A. via Antica, 24/3 33048 San Giovanni al Natisone (UD) +39 0432 747211 - [email protected] www.catas.com
Testing site: via Braide Matte, 4 33048 San Giovanni al Natisone (UD) tel. +39 0432 747211 [email protected]
appl.rib.ind.180 NType of chair: fixed geometry
: 20 N does not overturn
Minimum horizontal force for rearwards overturning of fixed back chair: 167 N
Forwards overturning Horizontal force
Rearwards overturning
: 167 N does not overturn Fixed back chair Horizontal force
Tilting chair in the rearmost position: /
N does not overturn
Loading discs on the seat
Sideways overturning for chairs with arms: 20 Horizontal force
Sideways overturning for chairs without arms: / Horizontal force
Forwards overturning for chairs with footrest: / Horizontal force
The test result complies with the requirements of EN 1022:2005
pag. 1/1
The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.
This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.
Managing Director Dr. Andrea Giavon