R801S- (Upflow/Horizontal) Series 80% A.F.U.E.† Input Rates 50-150 kBTU Annual Fuel Utilization Efficiency - AFUE THIS MODEL ENER UIDE HIGH MID 80.0% A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures. FORM NO. G22-542 REV. 5 Gas Furnaces R801S (UF/HZ) Series Rely on Ruud.™ Ruud Achiever ® Series Upflow/Horizontal Gas Furnace Ruud Achiever ® Series Upflow/Horizontal Gas Furnace 80% residential Gas Furnace CSA certified 3 way multi poise design UF / HZ PlusOne Diagnostics — 7 Segment LED all units PlusOne Ignition System – DSI for reliability and longevity Heat exchanger is removable for improved serviceability. Aluminized steel construction provides maximum corrosion resistance and thermal fatigue reliability. Solid doors provide quiet operation Low profile 34" cabinet ideal for space constrained installations Blower shelf design – serviceable in all furnace orientations Hemmed edges on cabinets and doors 1/4 turn door knobs for tool less access Integrated Controls board features dip switches for easy system set up QR codes for quick access to product information from your smart phone or tablet

Ruud Achiever Achiever Series Series Upflow/Horizontal Gas

  • Upload
    others

  • View
    12

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Ruud Achiever Achiever Series Series Upflow/Horizontal Gas

R801S- (Upflow/Horizontal) Series80% A.F.U.E.†Input Rates 50-150 kBTU

Annual Fuel Utilization Efficiency - AFUE

THIS MODEL

ENER UIDE

97%78%

HIGHMID82% 88%

80.0%

†A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance withDepartment of Energy test procedures.

FORM NO. G22-542 REV. 5

Gas FurnacesR801S (UF/HZ) Series

Rely on Ruud.™

Ruud Achiever® SeriesUpflow/Horizontal Gas FurnaceRuud Achiever® SeriesUpflow/Horizontal Gas Furnace

• 80% residential Gas Furnace CSA certified• 3 way multi poise design UF / HZ• PlusOne™ Diagnostics — 7 Segment LED all units• PlusOne™ Ignition System – DSI for reliability and longevity• Heat exchanger is removable for improved serviceability.

Aluminized steel construction provides maximum corrosionresistance and thermal fatigue reliability.

• Solid doors provide quiet operation

• Low profile 34" cabinet ideal for space constrained installations

• Blower shelf design – serviceable in all furnace orientations• Hemmed edges on cabinets and doors• 1/4 turn door knobs for tool less access• Integrated Controls board features dip switches for easy system

set up• QR codes for quick access to product information from your

smart phone or tablet

Page 2: Ruud Achiever Achiever Series Series Upflow/Horizontal Gas

Rely on Ruud.™2

Standard & Optional Equipment ......................................................................3

Model Features/Physical Data & Specifications ................................................4

Model Number Identification ............................................................................5

Dimensional Data ........................................................................................6-7

Blower Performance Data................................................................................8

Accessories....................................................................................................9

Limited Warranty ..........................................................................................10

TABLE OF CONTENTSTABLE OF CONTENTS

Table of ContentsR801S (UF/HZ) Series

Page 3: Ruud Achiever Achiever Series Series Upflow/Horizontal Gas

Rely on Ruud.™ 3

WARNINGTHIS FURNACE IS NOT APPROVED

OR RECOMMENDEDFOR USE IN MOBILE HOMES

DIRECT SPARK IGNITOR

IN-SHOT BURNERS

DRAFT INDUCER MOTOR

PATENTED HEAT EXCHANGER

INTEGRATEDFURNACECONTROL

STANDARD EQUIPMENTCompletely assembled and wired; induced draft; pressure switch;redundant main gas control; blower compartment door safety switch;solid state time on/time off blower control; limit control; manual shut-off valve, pressure regulator for natural and L.P. (propane) gas;transformer; direct drive multi-speed blower motor. Furnaces areequipped with cooling/heating relay and transformer (40VA) ready forair conditioning applications. (Please note: a thermostat is notincluded as standard equipment.) Flame sensor diagnostics.

OPTIONAL EQUIPMENTSide and bottom filter frame assembly. Return air cabinet for all sizes.NOTE: Furnace is not listed for use with fuels other than natural or L.P.

(propane) gas.The complete terms of limited and other warranties are available at oursales office, or through local installer.All models can be converted by a qualified Ruud distributor or localservice dealer to use L.P. (propane) gas without changing burners.Factory approved kits must be used to convert from natural to L.P.(propane) gas and may be ordered as optional accessories from aRuud parts distributor.For L.P. (propane) operation, refer to Conversion Kit Index Form.NOTE: For natural and L.P. (propane) gas models, direct spark ignitionis 100% safety lockout type.

Standard & Optional EquipmentR801S (UF/HZ) Series

Page 4: Ruud Achiever Achiever Series Series Upflow/Horizontal Gas

Rely on Ruud.™4

MODEL NUMBERS R801S SERIES R801SA050314M*A R801SA075317M*A R801SA075417M*A R801SA100417M*A R801SA100521M*A R801SA125524M*A R801SA150524M*A

Input-BTU/Hr ➁ 50,000 75,000 75,000 100,000 100,000 125,000 150,000

Heating Capacity BTU/Hr ➀ 41,000 61,000 61,000 82,000 81,000 101,000 122,000

Heat Ext. Static Pressure .18 .20 .20 .28 .28 .28 .28

Blower (D x W) 11 x 6 11 x 7 11 x 7 11 x 7 11 x 10 11 x 10 11 x 10

Motor H.P.–Speed–Type 1/3-4-PSC 1/2-4-PSC 1/2-4-PSC 1/2-4-PSC 1/2-4-PSC 3/4-4-PSC 3/4-4-PSC

Min Circuit Ampacity 9 10 9 11 9 12 13

Min. Overload Protection 15 15 15 15 15 15 15

Max. Overload Protection 15 15 15 15 15 15 20

Motor Full Load Amps 5.7 6.7 7.8 7.8 7.5 8.4 9.3

Heating Speed Med-Low Med-High Med-High Med-High Med-Low Med-High Med-High

Cooling Speed High Med-High High Med-High High High High

Cooling CFM @ .70" W.C. E.S.P. 1164 1198 1657 1292 1807 1742 1916

Max. E.S.P. (In. W.C.) 0.8 0.8 0.8 0.8 0.8 0.8 0.8

Temperature Rise Range °F 25-55 25-55 25-55 35-65 35-65 35-65 45-75

Max. Outlet Air Temp. °F 155 155 155 165 180 165 190

Approx. Shipping Weight (Lbs.) 110 110 125 110 140 150 160

AFUE ➀ 80.0% 80% 80.0% 80.0% 80.0% 80.0% 80.0%

NOTES: All models are 115V, 60HZ, 1 Ph. Gas connection size for all models is 1/2" N.P.T. ➀ In accordance with D.O.E. test procedures. ➁ See Conversion Kit Index Form for high altitude derate. * S = Standard, X = Low Nox

• 80% residential Gas Furnace CSA certified• 3 way multi poise design UF / HZ• PlusOne™ Diagnostics — 7 Segment LED all units• PlusOne™ Ignition System – DSI for reliability and longevity• Heat exchanger is removable for improved serviceability.

Aluminized steel construction provides maximum corrosionresistance and thermal fatigue reliability.

• Solid doors provide quiet operation

• Low profile 34" cabinet ideal for space constrained installations

• Blower shelf design serviceable in all furnace orientations• Hemmed edges on cabinets and doors• 1/4 turn door knobs for tool less access• Integrated Controls board features dip switches for easy

system set up• QR codes for quick access to product information from your

smart phone or tablet

Model Features

Physical Data and Specifications

Model Features/Physical Data & SpecificationsR801S (UF/HZ) Series

Page 5: Ruud Achiever Achiever Series Series Upflow/Horizontal Gas

R 80 1 S A 075 4 17 M S A

Ruud 80 =80% AFUE

1 = Single Stage S = PSC Motorw/Standard

Cabinet

Design SeriesA = 1st Design

InputBTU/HR

050 = 50,000075 = 75,000100 = 100,000125 = 125,000150 = 150,000

3 = Up to3 Ton

4 = Up to4 Ton

5 = Up to5 Ton

CabinetWidth

14 = 14".017 = 17.5"21 = 21".024 = 24.5"

M = Multi X = Low NOx

S = StandardRevision-Marketing

(A – First TimeRelease)

Rely on Ruud.™ 5

Model Number Identification

Model Number IdentificationR801S (UF/HZ) Series

Page 6: Ruud Achiever Achiever Series Series Upflow/Horizontal Gas

Rely on Ruud.™6

Upflow Application

MODELR801S- A B C D E F

MINIMUM CLEARANCE (IN.) SHIPWGTS.(LBS.)

LEFTSIDE

RIGHTSIDE BACK TOP FRONT VENT

050 141/2 1227/32 105/8 ➀ 111/2 17/8 0 4 ➁ 0 1 3 6 ➂ 85075/

100417 171/2 1611/32 123/8 ➀ 151/2 21/2 0 3 ➁ 0 1 3 6 ➂ 105

10052 211/2 1927/32 141/8 ➀ 181/2 21/2 0 0 0 1 3 6 ➂ 120125 241/2 2311/32 157/8 ➀ 221/2 21/2 0 0 0 1 3 6 ➂ 140150 241/2 2311/32 157/8 ➀ 221/2 21/2 0 0 0 1 3 6 ➂ 150.

NOTES: ➀ May require a 3" to 4" or 3" to 5" adapter. 4". ➁ May be 0" with type B vent. ➂ May be 1" with type B vent. Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and/or Can/CGA-B149 Installation Codes and in accordance with

local codes.

Dimensional Data: Upflow Model

Dimensional DataR801S (UF/HZ) Series

Page 7: Ruud Achiever Achiever Series Series Upflow/Horizontal Gas

Rely on Ruud.™ 7

MODELR801S- A B C D E F

MINIMUM CLEARANCE (IN.) SHIPWGTS.(LBS.)

SUPPLYAIR SIDE

RETURNAIR SIDE BACK TOP FRONT VENT

050 141/2 1227/32 105/8 ➀ 111/2 17/8 4 ➁ 0 0 1 3 6 ➂ 85075/

100417 171/2 1611/32 123/8 ➀ 151/2 21/2 3 ➁ 0 0 1 3 6 ➂ 105

100521 211/2 1927/32 141/8 ➀ 181/2 21/2 0 0 0 1 3 6 ➂ 120125 241/2 2311/32 157/8 ➀ 221/2 21/2 0 0 0 1 3 6 ➂ 140150 241/2 2311/32 157/8 ➀ 221/2 21/2 0 0 0 1 3 6 ➂ 150.

NOTES: ➀ May require a 3" to 4" or 3" to 5" adapter. 4" adapter included with (-)801P units. ➁ May be 0" with type B vent. ➂ May be 1" with type B vent. Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and/or Can/CGA-B149 Installation Codes and in accordance with

local codes.

Dimensional Data: Horizontal Model

Horizontal Application

WARNINGTHIS FURNACE IS NOT APPROVED

OR RECOMMENDED FOR INSTALLATIONON ITS BACK, WITH ACCESS DOORS

FACING UPWARDS.

Dimensional DataR801S (UF/HZ) Series

Page 8: Ruud Achiever Achiever Series Series Upflow/Horizontal Gas

Rely on Ruud.™8

MODELMOTOR H.P.

BLOWER SIZE IN

SPEEDTAP

CFM AIR DELIVERYEXTERNAL STATIC PRESSURE INCHES WATER COLUMN

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

(-)801SA050314M*A 1/311 x 6

LowMed. LoMed. Hi

High

823103011291361

803101811321353

787100611121331

73297610871297

71892910541264

69189710281232

6518509711164

5938089191117

(-)801SA075317M*AA 1/211 x 7

LowMed. LoMed. Hi

High

1008121514211668

977118114081648

935113313721633

893109813261580

854106512991545

823102312471481

77797511981442

73593711521373

(-)801SA075417M*A 1/211 x 7

LowMed. LoMed. Hi

High

1229130815531969

1200126715421924

1181126615161893

1155123314911840

1120120414511803

1078117614171728

1013111313581657

970106213061570

(-)801SA100417M*A 1/211 x 7

LowMed. LoMed. Hi

High

1211130515201874

1183126114981810

1148122514641767

1116118514271686

1077115713871678

1040111313401650

984106812921582

953101212261497

(-)801SA100521M*A 1/211 x 10

LowMed. LoMed. Hi

High

1209143819022071

1182142018832037

1131138618442001

1112135018171962

1051132017531905

976129317001856

929124816361807

867118615471709

(-)801SA125524M*A 3/411 x 10

LowMed. LoMed. Hi

High

1358154117992015

1354151717741989

1331147617461929

1301145317121902

1250141616911862

1224137116291815

1154133915541742

1089127714951665

(-)801SA150524M*A 3/411 x 10

LowMed. LoMed. Hi

High

1411160618892178

1395157918912160

1370156918492105

1334153718282067

1310149917642024

1252146817171976

1220140716591916

1150134616091832

Note: Bold data is factory heating tap. Table represents blower performance data WITHOUT filters.

Blower Performance Data

Blower Performance DataR801S (UF/HZ) Series

Page 9: Ruud Achiever Achiever Series Series Upflow/Horizontal Gas

Rely on Ruud.™ 9

FILTER RACK FILTER SIZES* INCHES

MODELRXGF-CB(UPFLOW/

HORIZONTAL)

RXGF-CD(UPFLOW)

SIDE RETURN

R801SA050 121/4 x 25 153/4 x 25

R801SA075R801SA100417 153/4 x 25 153/4 x 25

R801SA100521 191/4 x 25 153/4 x 25

R801SA125 223/4 x 25 153/4 x 25

R801SA150 223/4 x 25 153/4 x 25

WARNING: IMPORTANT NOTICEA SOLID METAL BASE PLATE (SEE TABLE) MUST BE IN PLACE WHEN THE FURNACE ISINSTALLED WITH SIDE AIR RETURN DUCTS. FAILURE TO INSTALL A BASE PLATE COULD CAUSEPRODUCTS OF COMBUSTION TO BE CIRCULATED INTO THE LIVING SPACE AND CREATEPOTENTIALLY HAZARDOUS CONDITIONS. FURNACE BASE WIDTH SOLID BOTTOM BASE PLATE SIZE IN. KIT NO. PLATE NO. IN.

141/2 RXGB-D14 AE-61874-01 115/8 x 239/16

171/2 RXGB-D17 AE-61874-02 151/8 x 239/16

211/2 RXGB-D21 AE-61874-03 185/8 x 239/16

241/2 RXGB-D24 AE-61874-04 255/8 x 239/16

FOR HIGH ALTITUDES:OPTION CODE FOR HIGH ALTITUDE: U.S. & CanadaNone required for high altitudes.

HIGH ALTITUDE CONVERSION KITS: U.S. & CanadaNone required for high altitudes.

80+ HIGH ALTITUDE INSTRUCTIONS CAUTION: Always follow National Fuel Gas Code (NFGC) guidelineswhen converting for high altitudes.

High altitude option codes are not required for these models.However, the burner orifice size needs to be recalculated and verifiedat elevations above 2000 ft. See Installation Instructions for moreinformation.

NOTE: For Canadian installations only, an optional derate (manifoldgas pressure reduction) method may be used to adjust thefurnace for altitude. See Installation Instructions for moreinformation. This optional method may NOT be used for U.S.installations.

SIDE RETURN FILTER RACK: RXGF-CDBOTTOM RETURN FILTER RACK FORUPFLOW APPLICATION: RXGF-CB

4" FLUE ADAPTER: RXGW-C01

INDOOR COIL CASINGSMODEL

NUMBER

RXBC-D14AIRXBC-D17AIRXBC-D21AIRXBC-D21BIRXBC-D24AI

AccessoriesR801S (UF/HZ) Series

Page 10: Ruud Achiever Achiever Series Series Upflow/Horizontal Gas

Rely on Ruud.™10

GENERAL TERMS OF LIMITED WARRANTY*Ruud will furnish a replacement for any part of this productwhich fails in normal use and service within the applicableperiod stated, in accordance with the terms of the limited warranty.*For complete details of the Limited and Conditional Warranties,including applicable terms and conditions, contact your local contractoror the Manufacturer for a copy of the product warranty certificate.

Conditional Parts* (Registration Required) ......Ten (10) YearsHeat Exchanger ......................................Twenty (20) Years

Limited WarrantyR801S (UF/HZ) Series

Page 11: Ruud Achiever Achiever Series Series Upflow/Horizontal Gas

Rely on Ruud.™ 11

NotesR801S (UF/HZ) Series

Page 12: Ruud Achiever Achiever Series Series Upflow/Horizontal Gas

Rely on Ruud.™

PRINTED IN U.S.A. 3/17 QG FORM NO. G22-542 REV. 5

Rely on Ruud.™

Ruud Heating, Cooling & Water Heating • P.O. Box 17010Fort Smith, Arkansas 72917 • www.ruud.com

In keeping with its policy of continuous progress and product improvement, Ruud reserves the right to make changes without notice.

Ruud Canada • 125 Edgeware Road, Unit 1Brampton, Ontario • L6Y 0P5