21
Relocation of Daresbury MEIS to Huddersfield University Paul Bailey UK MEIS Facility STFC Daresbury Laboratory, UK

Relocation of Daresbury MEIS to Huddersfield University Paul Bailey UK MEIS Facility STFC Daresbury Laboratory, UK

  • View
    223

  • Download
    3

Embed Size (px)

Citation preview

Page 1: Relocation of Daresbury MEIS to Huddersfield University Paul Bailey UK MEIS Facility STFC Daresbury Laboratory, UK

Relocation of Daresbury MEIS to Huddersfield

University

Paul BaileyUK MEIS Facility

STFC Daresbury Laboratory, UK

Page 2: Relocation of Daresbury MEIS to Huddersfield University Paul Bailey UK MEIS Facility STFC Daresbury Laboratory, UK

Huddersfield8th December 2011

Daresbury MEIS

Page 3: Relocation of Daresbury MEIS to Huddersfield University Paul Bailey UK MEIS Facility STFC Daresbury Laboratory, UK

Daresbury MEIS

Huddersfield8th December 2011

Page 4: Relocation of Daresbury MEIS to Huddersfield University Paul Bailey UK MEIS Facility STFC Daresbury Laboratory, UK

Huddersfield8th December 2011

Daresbury MEIS

Page 5: Relocation of Daresbury MEIS to Huddersfield University Paul Bailey UK MEIS Facility STFC Daresbury Laboratory, UK

Important Aspects of the New Machine

Huddersfield8th December 2011

Some components are contaminated with 14C and 3H (very low level)Every component removed has to be cleared for radiation, recorded and labelled

The ion source and power supplies need to float to high ~ 200 kV voltageso require a high voltage platform

Need to design and manufacture a 200 kV acceleration lens

Need to consider the state of the control system

Page 6: Relocation of Daresbury MEIS to Huddersfield University Paul Bailey UK MEIS Facility STFC Daresbury Laboratory, UK

Radioactivity

Huddersfield8th December 2011

Some components are contaminated with 14C and 3H (very low level)Every component removed has to be cleared for radiation, recorded and labelled

Page 7: Relocation of Daresbury MEIS to Huddersfield University Paul Bailey UK MEIS Facility STFC Daresbury Laboratory, UK

High Voltage Platform

Huddersfield8th December 2011

2 spare insulating legsrated at 500 kV havebeen split into 4 ratedat 250 kV

maximum beam energywas 500 kVwe only ever used upto 200 kVso limit new facility to200 kV

0.75 m

Page 8: Relocation of Daresbury MEIS to Huddersfield University Paul Bailey UK MEIS Facility STFC Daresbury Laboratory, UK

Acceleration lens

Huddersfield8th December 2011

We need an acceleration lens to increase the beam energy from

20 kV up the final energy

Usually use 100 kV, but 200 kV maximum is needed

The one we use is 14C contaminated – no good!

So, we get one made by ‘beefing up’ Jaap’s 100 kV design

But the manufacturer cannot accommodate the size required

So we buy 2 100 kV lenses

But the cost goes up to £20k

We have a spare but this is labelled as 3H contaminated – any good?

Testing reveals no discernable activity – good!

Page 9: Relocation of Daresbury MEIS to Huddersfield University Paul Bailey UK MEIS Facility STFC Daresbury Laboratory, UK

Acceleration lens

Huddersfield8th December 2011

Close inspection reveals a modular construction

1.5 m

Page 10: Relocation of Daresbury MEIS to Huddersfield University Paul Bailey UK MEIS Facility STFC Daresbury Laboratory, UK

Acceleration lens

Huddersfield8th December 2011

Should be OK if we can dismantle it without damage

Page 11: Relocation of Daresbury MEIS to Huddersfield University Paul Bailey UK MEIS Facility STFC Daresbury Laboratory, UK

Control System

Huddersfield8th December 2011

Whilst MEIS has a working control system, we have no expertise

or support if something goes wrong

Essentially we have been using it on ‘borrowed’ time

We need a control system because of the complexity of MEIS and

because we have power supplies that float at high voltages

Do we try and use the existing control system?

What are the alternatives?

Page 12: Relocation of Daresbury MEIS to Huddersfield University Paul Bailey UK MEIS Facility STFC Daresbury Laboratory, UK

Control System(s)

Huddersfield8th December 2011

A simple way to control at high voltages

Page 13: Relocation of Daresbury MEIS to Huddersfield University Paul Bailey UK MEIS Facility STFC Daresbury Laboratory, UK

Control System(s)

Huddersfield8th December 2011

A better way?

Page 14: Relocation of Daresbury MEIS to Huddersfield University Paul Bailey UK MEIS Facility STFC Daresbury Laboratory, UK

Control System(s)

Huddersfield8th December 2011

Page 15: Relocation of Daresbury MEIS to Huddersfield University Paul Bailey UK MEIS Facility STFC Daresbury Laboratory, UK

Control System(s)

Huddersfield8th December 2011

Unfortunately... this is the wiring for one EQT

Page 16: Relocation of Daresbury MEIS to Huddersfield University Paul Bailey UK MEIS Facility STFC Daresbury Laboratory, UK

Control System

Huddersfield8th December 2011

The plan is - to bring the existing system to Huddersfield

But, I think we need to look at alternatives with some haste

Page 17: Relocation of Daresbury MEIS to Huddersfield University Paul Bailey UK MEIS Facility STFC Daresbury Laboratory, UK

liftingframe

HT platform1.5x2.0

HT enclosure3.5x3.5

Raised floor5.5x5.5

Accommodation

11.0 m

Page 18: Relocation of Daresbury MEIS to Huddersfield University Paul Bailey UK MEIS Facility STFC Daresbury Laboratory, UK

Beamline Magnet

Huddersfield8th December 2011

We have a smaller magnet which is much lighter (existing is 5 Tonnes)

But its horizontal focusing is too strong

Page 19: Relocation of Daresbury MEIS to Huddersfield University Paul Bailey UK MEIS Facility STFC Daresbury Laboratory, UK

Relocation of Daresbury MEIS to Huddersfield

University

Paul BaileyUK MEIS Facility

International Institute for Accelerator Applications

Huddersfield University, UK

Page 20: Relocation of Daresbury MEIS to Huddersfield University Paul Bailey UK MEIS Facility STFC Daresbury Laboratory, UK

Huddersfield8th December 2011

Page 21: Relocation of Daresbury MEIS to Huddersfield University Paul Bailey UK MEIS Facility STFC Daresbury Laboratory, UK

Huddersfield8th December 2011