RECEIVER DRIERS © 2017 MEI Corporation 516 RECEIVER DRIERS Table of Contents ACCUMULATORS Specification Chart .................................................. 524 Visual Illustration Section ....................................... 529 RECEIVER DRIERS RECEIVER DRIERS Block, Manifold, Pad or Slimline Type ..................... 518 Cartridges/Elements ................................................ 522 Flare Type................................................................ 522 In-Line Filters .......................................................... 523 O’ring Type.............................................................. 519 Quick Disconnect Type ............................................ 522 Visual Illustration Section ....................................... 527 Receiver Driers, Accumulators, and In-Line Filters are canisters used to filter debris and remove moisture to protect the a/c system. Various inlet and outlet fitting types and sizes are used. Many also have system protection devices, moisture indicators, charge ports, sight glass, fuse plugs, high pressure relief valves, mounting brackets depending on the requirements from the original equipment manufacturer. Receiver Driers are usually located on the high side of the a/c system before the expansion valve. The receiver drier “receives” liquid refrigerant from the condenser, stores it, filters out contaminates from the a/c system, and removes moisture. A/C systems using a receiver drier use an expansion valve to control the refrigerant flow. Accumulators are similar to that of the receiver drier. It is usually mounted on the low side, at the outlet of the evaporator. The accumulator “accumulates” or stores excess refrigerant, filters and dries the refrigerant. Accumulators are used on CCOT (Cycling Clutch Orifice Tube) or FFOT (Ford Fixed Orifice Tube) systems. These systems use a orifice tube instead of an expansion valve to control the refrigerant flow. Basic Information RELATED ITEMS Adapters, Drier Port ................................................ 339 Moisture Indicators ................................................. 526 Mounting Bracket Kits............................................. 526 O’rings & Seals ....................................................... 511 Quick Disconnect Couplers ..................................... 526 Studs - for Accum/Driers, Cond., Exp.Vlvs. ........... 607 Typical Drier System (illustration) ........................... 523 Typical Accumulator CCOT (illustration) ................. 525 NOTE DRIER MEASUREMENTS DIAMETER LENGTH Receiver Drier manufacturers have discontinued using moisture indicators and in some cases sight glases. AirSource will only supply driers with moisture indicators, and sight glass while supply lasts.

Receiver Driers Accumulators, and In-Line Filters Receiver

  • Upload
    others

  • View
    14

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Receiver Driers Accumulators, and In-Line Filters Receiver

RE

CE

IVE

R D

RIE

RS

© 2017 MEI Corporation516

RECEIVER DRIERS Table of Contents

ACCUMULATORSSpecification Chart ..................................................524Visual Illustration Section .......................................529

RECEIVER DRIERS

RECEIVER DRIERSBlock, Manifold, Pad or Slimline Type .....................518 Cartridges/Elements ................................................522Flare Type ................................................................522 In-Line Filters ..........................................................523 O’ring Type ..............................................................519 Quick Disconnect Type ............................................522Visual Illustration Section .......................................527

Receiver Driers, Accumulators, and In-Line Filters are canisters used to filter debris and remove moisture to protect the a/c system. Various inlet and outlet fitting types and sizes are used. Many also have system protection devices, moisture indicators, charge ports, sight glass, fuse plugs, high pressure relief valves, mounting brackets depending on the requirements from the original equipment manufacturer.

Receiver Driers are usually located on the high side of the a/c system before the expansion valve. The receiver drier “receives” liquid refrigerant from the condenser, stores it, filters out contaminates from the a/c system, and removes moisture. A/C systems using a receiver drier use an expansion valve to control the refrigerant flow.

Accumulators are similar to that of the receiver drier. It is usually mounted on the low side, at the outlet of the evaporator. The accumulator “accumulates” or stores excess refrigerant, filters and dries the refrigerant. Accumulators are used on CCOT (Cycling Clutch Orifice Tube) or FFOT (Ford Fixed Orifice Tube) systems. These systems use a orifice tube instead of an expansion valve to control the refrigerant flow.

Basic Information

RELATED ITEMSAdapters, Drier Port ................................................339Moisture Indicators .................................................526 Mounting Bracket Kits .............................................526 O’rings & Seals .......................................................511Quick Disconnect Couplers .....................................526Studs - for Accum/Driers, Cond., Exp.Vlvs. ...........607Typical Drier System (illustration) ...........................523Typical Accumulator CCOT (illustration) .................525

NOTE

DRIER MEASUREMENTS

DIAMETER

LENGTH

Receiver Drier manufacturers have discontinued using moisture indicators and in some cases sight glases.AirSource will only supply driers with moisture indicators, and sight glass while supply lasts.

Page 2: Receiver Driers Accumulators, and In-Line Filters Receiver

RE

CE

IVE

R D

RIE

RS

© 2017 MEI Corporation 517

RECEIVER DRIERS

Moisture can be harmful to air conditioning systems, components and to the a/c system’s operation. For this reason, any time the a/c system is opened, the receiver drier / accumulator needs to be replaced. A good preventative maintenance practice is to replace the receiver drier or the accumulator and orifice tube at regular intervals or at least once per year. When replacing a compressor, the a/c compressor manufacturer’s warranty will be void without proof of flushing the system, and also replacement of the receiver drier.

Moisture Indicator - a litmus paper device which turns colors to designate condition of the refrigerant. Blue - Normal, Pink - Moisture in system, White - Very Wet, Grayish - oil contamination. Manufactures have discontinued using moisture indicators. We will supply until stock is exhausted.

Pressure Relief Valve / Fuse Plug - A protection device designed to open and “bleed off” excessive pressure that may occur. The Fuse Plug is a bi-metal device which will “melt down” to release excess pressure.

Sightglass - a “window” for observing the condition of the refrigerant.

Schrader Valve - a gauge or charge port which allows access to the system, for charging or checking the pressures. Switch Port - Low / High Pressure Switches - a switch port allows for a male or female pressure switch to be added to the drier. If low charge is detected, the low pressure switch opens electronically and stops the compressor operation. Similarily, as pressure increases, the high pressure switch will dis-engage the clutch and re-engage when pressure normalizes.

Quick Disconnect

Quick Disconnect

SightGlass

SightGlass

SightGlass

Pad Type

Male Flare Type (R12 only)

Male O’ring Type

Female O’ringType

Charge/ Gauge Port

Charge/Gauge Port

High PressureRelief Valve

High PressureRelief Valve

Low / HighPressure Switch

FusePlug

FemaleO’ring Type

MaleO’ring Type

Charge/ Gauge Port

High PressureRelief Valve

Typical Examples:

Slimline Manifold - Block Type

MaleSpringlock Type

FemaleSpringlock Type

Metric Schrader Valve uses green o’ring seals.

TECHTIP

Moisture indicator is not required and may not be supplied on drier.

Sight Glass(some models)

Switch Port(some models)

Moisture Indicator(not required)

Moisture Indicator(not required)

Page 3: Receiver Driers Accumulators, and In-Line Filters Receiver

RE

CE

IVE

R D

RIE

RS

© 2017 MEI Corporation518

RECEIVER DRIERSListed in ascending order by Diameter x Length by Fitting Type and Size.

Block, Pad, Manifold, SlimLine, or SpringLock Style Fittings

Switc

h Po

rt

Schr

ader

Va

lve

Pres

sure

R

elie

f Val

ve

Moi

stur

e In

dica

tor

PA

RT

NU

MB

ER

Inlet and Outlet and Dia. LENGTH TYPE O’ring Size O’ring Size Note Charge

1 5/8” 11-5/8” Pad Type O’ring 0011 O’ring 0011 7557 Sprinter Van 680-013634AA R134a2” 11 3/4” - - - 7617 Manitou MLA628 OE# 5642072 3/8” 7 1/2” Pad Type - - 7592 Volvo Exv EC Series, 14509377 R134a2 3/8” 9” Pad Type - - 7420 Top (2) Fem JD Excavator, 4448179;4646799 R134a2.36” 7.38” Pad Type - - 7621 John Deere OE# RE380910 (aluminum)2.36” 8.98” Pad Type - - 7618 3/8”-24 w/Binary Sw., Hyundai OE# 11N6-900602.36” 9” Pad Type - - 7620 Top (2) John Deere (aluminum)2.38” 9.5” Pad Type - - 7615 Kubota T2055-722302 3/8” 10 1/4” Pad Type - - 7626 CAT 327-65582 3/8” 10 1/4” Pad Type - - 7634 Komatsu 51440-A1180 (aluminum) R134a2 .4” 10” Pad Type O’ring 0025 O’ring 0025 7568 CAT 176-19022 1/2” 6” Pad Type - - 7619 3/8”-24 John Deere OE# AL204865 (steel) 2 1/2” 7” Pad Type O’ring 0011 O’ring 0011 7547 Caterpillar 113-34972 1/2” 8 1/4” Pad Type O’ring 0110 O’ring 0110 7556 Sprinter Van 2.7L, 051-03570AA R134a2 1/2” 9” Pad Type - - 7599 Top w/Trinary Sw., GMC/ISUZU 8-98039-052-02 1/2” 9” Pad Type - - 7625 Top w/Low Press. Sw., CAT 125-16422 1/2” 10” PadType O’ring 0011 O’ring 0011 7546 CAT 176-1902; Komatsu 20Y-979-3202 1/2” 10 3/4” Pad Type washer #0165 washer #0165 7616 CAT OE# 320-0562; 320-0563 (steel) 2 3/4” 10” Pad Type - - 7571 Mitsubishi Fuso 2.9” 9” Pad Type O’ring 0025 O’ring 0025 7569 M10 3/8”-24 port; Linkbelt Exv YT54500003P1 3” 7” Side Pad 7629 CAT 355-1793 (steel) R134a 3” 9” Pad Type - - 7418 Mack Freedom Class 5010463763 R134a 3” 10” Slimline #6 seals 0126 seals 0126 7197 (2) M10 Top N83-319744 R134a 3” 10 1/4” Slimline #6 seals 0126 seals 0126 7198 (2) M10 Top use #0126 seals, N83-319534 R134a 3” 10 1/2” Pad /Block O’ring 0135 O’ring 0135 7545 16mm Volvo Off-Road 11104567 R134a 3” 10 5/8” Pad Type seals 0130 seals 0131 7412 PACCAR F37-1017-100 R134a 3” 10 5/8” Pad Type - - 7413 PACCAR F37-1017-200 R134a 3” 10 5/8” Pad Type - - 7424 Kenworth F37-1021 (steel) 3” 11” Pad Type #8, Seal 0131 #8, Seal 0131 7414 Kenworth F37-6017 R134a 3” 11” Manifold O’ring 0011 O’ring 0011 7393 Kenworth F37-6000 R134a 3” 11” Pad Manifold - - 7397 Peterbilt F37-6002 R134a 3” 11” Pad Manifold - - 7398 Peterbilt F37-6003 R134a 3” 11” Pad Manifold - - 7399 Peterbilt F37-6009 R134a 3” 11” Pad Type - - 7411 Peterbilt F37-1019 R134a 3” 14.35” Springlock SL 3/8” #6 SL 3/8” #6 7564 Side Ford New Holland R134a 4” 7” Block Style Stat Seal #8 Stat Seal #8 7559 Frghtlnr A22-63992-000, -001 R134a 4” 7” Block Style Stat Seal #8 Stat Seal #8 7566 Frghtlnr A22-63994-001 R134a 4” 7” Pad Type Stat Seal 0131 Stat Seal 0131 7585 Frghtlnr 22-66700-000 R134a 4” 7” Pad Type Stat Seal 0131 Stat Seal 0131 7586 Frghtlnr 22-66600-000 R134a - - Pad Type - - 7602 ISUZU 8-97366-991-0 - - Pad Type - - 7603 ISUZU 8-97308-332-0 - - Pad Type - - 7604 ISUZU 1-83535-068-0 - - Pad Type - - 7605 ISUZU 8-97183-124-0 - - Pad Type - - 7606 ISUZU 8-97175-137-0 - - Pad Type - - 7607 ISUZU 8-97118-190-1 - - Pad Type - - 7608 ISUZU 1-83535-095-0 - - Pad Type - - 7609 ISUZU 1-83535-080-0 w/switch - - Pad Type - - 7421 (2 ports) International 4000, 7000, 8000 Series 3839360-C92 - - Pad Type - - 7422 (3 ports) International 4000, 7000, 8000 Series 3843558-C92 - - Pad Type - - 7635 Top Mack / Volvo OE# 82771584 R134a

Page 4: Receiver Driers Accumulators, and In-Line Filters Receiver

RE

CE

IVE

R D

RIE

RS

© 2017 MEI Corporation 519

RECEIVER DRIERS

Receiver Drier manufacturers have discontinued using moisture indicators and in some cases sight glases.AirSource will only supply driers with moisture indicators, and sight glass while supply lasts.NOTE

Listed in ascending order by Diameter x Length by Fitting Type and Size (continued).

1 3/4” 20 1/2” #6 Flare #6 Flare 7622 CAT OE# 1P6541 R134a2” 8 1/2” #6 MIO #6 MIO 7119 Top (2) R12 Multi fit applications R12/R134a2 1/2” 8” 3/8” #6 3/8” #6 7122 Top 1/4” NPT Side Thermo King Tri-Pac #61-3552 R134a2 3/4” 6” #6 MIO #6 MIO 7126D Top (2) Side 3/8 Male Port, 3/8 Female Port R134a 2 3/4” 8 1/2” #6 MIO #6 MIO 7579 R12 Volvo A25B; #11005931 R12/R134a2 3/4” 8 1/2” #6 MIO #6 MIO 7631 CAT 164-0622 (aluminum) R134a2 3/4” 10” 3/8” #6 3/8” #6 7154 Top Side R12/R134a2 3/4” 10” 3/8” #6 3/8” #6 7155 Top 1/4” Side Side Mack 221RD328 R12/R134a2 3/4” 10” 3/8” #6 3/8” #6 7155B Top Side Side Mack 221RD327 w/binary R12/R134a2 3/4” 10” 3/8” #6 3/8” #6 7156 Top Side Side R12/R134a2 3/4” 10” 3/8” #6 3/8” #6 7157 Top w/ Trinary Switch - #1550 R12/R134a2 3/4” 10” 3/8” #6 3/8” #6 7388 Side Top Side Kenworth K251-263 R12/R134a2 3/4” 10” 3/8” #6 3/8” #6 7389 Side Top Side IHC1691600C92 R12/R134a2 3/4” 10” 3/8” #6 3/8” #6 7390 Side Top Side w/ Trinary Switch - Top R12/R134a2 3/4” 10” 3/8” #6 3/8” #6 call Top Top Top 1/4” Side Side Mack 221RD327, w/Binary R12/R134a2 3/4” 10” #6 MIO #6 MIO 7153 Top (3) (2) Male Ports, (1) Female Port R134a 2.6” 11 3/8” 3/8” MIO 3/8” MIO 7570 Hino Truck R12/R134a2.6” 11 3/8” 14mm 14mm 7570M Side (2) female ports; Hino Truck R12/R134a2 7/8” 7 1/2” #6 MIO #6 MIO 7613 Side J.Deere 582166227 R134a

1 3/4” thru 2 7/8” Diameter - 3/8” Male O’ring INLET x 3/8” Male O’ring OUTLET

PA

RT

NU

MB

ER

Sigh

t Gla

ss

Switc

h Po

rt

Fuse

Plu

g

Schr

ader

Va

lve

Moi

stur

e In

dica

tor

Pres

sure

R

elie

f Val

ve

Low

Pre

ssur

e Sw

itch

Dia. LENGTH INLET OUTLET Note Charge

2 1/2” 6 5/16” 3/8” #6 Course Thrd 7513 Top (1) M10 33-0038A; 085623-00 R12/R134a2 1/2” 6 5/16” M18 Fine Thread 7514 Top (1) M10 33-0382A; 088370-0 R12/R134a2 1/2” 6 5/16” M18 M18 7515 Top (1) M10 33-0383A; 088371-00 R12/R134a2 1/2” 6 5/16” M18 Fine Thread 7519 Top (1) M10 Motorhome 085686-00 R12/R134a2 1/2” 6.32” M18 M18 7524 Top (1) M10 RV218337, 085722 R134a2 1/2” 6 3/4” 3/8” #6 MOR 1/2”#8 7140 In-Line Design, GMC R12/R134a2 1/2” 6 3/4” M18 MOR M20 7503 In-Line Drier; 15982368 R12/R134a2 1/2” 8” 3/8” #6 3/8” #6 7118 Top (2) Top 085268-03 (new style) R12/R134a2 1/2” 8” 3/8” #6 3/8” #6 7120 Top 1/4”Male Top use #1430 switch R12/R134a2 1/2” 8” MIO, M18 MIO, M18 7614 Top Doosan Excav., 2204-6039A R134a2 1/2” 8 1/4” 3/8” #6 3/8” #6 7480 Top Bracket R12/R134a2 1/2” 10” 3/8” #6 3/8” #6 7502 RD remote condenser R12/R134a

2 1/2” Diameter - 3/8” or M18 Male O’ring INLET w/Various Outlets

PA

RT

NU

MB

ER

Sigh

t Gla

ss

Fuse

Plu

g

Schr

ader

Va

lve

Moi

stur

e In

dica

tor

Pres

sure

R

elie

f Val

ve

Low

Pres

sure

Sw

itch

Switc

h Po

rt

Dia. LENGTH INLET OUTLET Note Charge

Page 5: Receiver Driers Accumulators, and In-Line Filters Receiver

RE

CE

IVE

R D

RIE

RS

© 2017 MEI Corporation520

RECEIVER DRIERSListed in ascending order by Diameter x Length by Fitting Type and Size (continued).

3” 6” 3/8” #6 3/8” #6 7125 Top Female Side R12/R134a3” 6 1/4” #6 Flare #6 Flare 7124 Side Side R12/R134a3” 6 1/4” 3/8” #6 3/8” #6 7593 Top Female Side Terex Loader SKL863, SKL873 R134a3” 6” 3/8” #6 3/8” #6 7129 Top Side R12/R134a3” 6 1/2” 3/8” #6 3/8” #6 7123 Top Male Top Side Red Dot RD5-7272-0 R12/R134a3” 6 1/2” 3/8” #6 3/8” #6 7126 Top 1/4” Male Side 088423-00; 01 R12/R134a3” 6 1/2” 3/8” #6 3/8” #6 7127 Top Side Binary (Side) R12/R134a3” 6 1/2” 3/8” #6 3/8” #6 7128 Top Side Trinary (Side) R12/R134a3” 6 1/2” 3/8” #6 3/8” #6 7555 Top Top Side N83-319634; RD5-9419-0 R12/R134a3” 6 1/2” 3/8” #6 3/8” #6 7594 Male CAT Exv., M318 / FNH EC2703” 8” 3/8” #6 3/8” #6 7161 (2) 1/4” R12/R134a3” 8” 3/8” #6 3/8” MIO 7580 Top Volvo 20490945 R134a3” 8 1/4” 3/8” #6 3/8” #6 7133 Top Female Side R12/R134a3” 8 1/4” 3/8” #6 3/8” #6 7141 Side Top R12/R134a3” 8 1/2” 3/8” #6 3/8” #6 7229 Top Female Top R12/R134a3” 8” 3/8” #6 3/8” #6 7180 Top (2) (2) M10 x 1.25mm R12/R134a3” 9” 3/8” #6 3/8” #6 7159 Top 1/4” Top Top Side R12/R134a3” 9” 3/8” #6 3/8” #6 7164 Top Side Top Side 1/8”-27NPT Port; 088254-01 R12/R134a3” 9” 3/8” #6 3/8” #6 7174 Top Side 20407203 R12/R134a3” 9” 3/8” #6 3/8” #6 7185 Top Top Inlet - Right Angle R12/R134a3” 9” 3/8” #6 3/8” #6 7419 Top Mack 221RD44M R134a3” 9 3/4” 3/8” #6 3/8” #6 7346 Top w/side mounting bracket R12/R134a3” 10” 3/8” #6 3/8” #6 7143 Top Side 1/4” Side Top R12/R134a3” 10” 3/8” #6 3/8” #6 7193 Top Side 1/4” Side Top Western Star R12/R134a3” 10” 3/8” #6 3/8” #6 7132 Side Side Top Top R12/R134a3” 10” 3/8” #6 3/8” #6 7134 Top Top Top Side Kenworth K251-566 R12/R134a3” 10” 3/8” #6 3/8” #6 7165 Top 1/4” Top Top Top R12/R134a3” 10” 3/8” #6 3/8” #6 7166 Top M10 Top Top Top M10 x 1.25mm R12/R134a3” 10” 3/8” #6 3/8” #6 7175 Side 1/4” fem Side 088079-00; 176237; K251-459 R12/R134a3” 10” 3/8” #6 3/8” #6 7189 Top w/side mounting bracket R12/R134a3” 10” 3/8” #6 3/8” #6 7190 Top Top w/side mounting bracket R12/R134a3” 10” 3/8” #6 3/8” #6 7567 Western Star 088586-00 R12/R134a3” 10 1/2” #6 MIO #6 MIO 7612 Side (3)1/4” Volvo 1089855 R134a3 1/2” 6 1/2” #6 MIO #6 MIO 7632 Side 7/16” Male Farm & Offroad w/bottom brkt R134a4” 6 1/2” 3/8” #6 3/8” #6 7394 Top w/mounting bracket R12/R134a4” 6 3/4” 3/8” #6 3/8” #6 7565 Side Side Volvo RD5-6075-0 R134a4” 7” 3/8” #6 3/8” #6 7232 Top Side Top Opposite Side Inlet R12/R134a4” 7 3/4” 3/8” #6 3/8” #6 7391 Top Top Side Side R134a4” 8 1/2” 3/8” #6 3/8” #6 7234 Top Side Top Top CAT# 5V5698; 8P9991 R12/R134a- - - - 7400 Side Bottom Top Carrier #65-00193-00; 088599-01

3” thru 4” Diameter - 3/8” Male O’ring INLET x 3/8” Male O’ring OUTLET

Low

Pre

ssur

e Sw

itch

PA

RT

NU

MB

ER

Sigh

t Gla

ss

Switc

h Po

rt

Fuse

Plu

g

Schr

ader

Va

lve

Moi

stur

e In

dica

tor

Pres

sure

R

elie

f Val

ve

Dia. LENGTH INLET OUTLET Note Charge

4” Diameter - 3/4” Male O’ring INLET x 3/4” O’ring OUTLET

Low

Pre

ssur

e Sw

itch

PA

RT

NU

MB

ER

Sigh

t Gla

ss

Switc

h Po

rt

Fuse

Plu

g

Schr

ader

Va

lve

Moi

stur

e In

dica

tor

Pres

sure

R

elie

f Val

ve

Dia. LENGTH INLET OUTLET Note

4” 8 1/2” 3/4” #12 3/4” #12 7624 fits Carrier 68AC430 Rooftop, 65-62004-00 4” 9 1/2” #12 MIO #12 FIOR 7630 CAT 374-5909 (steel)

Page 6: Receiver Driers Accumulators, and In-Line Filters Receiver

RE

CE

IVE

R D

RIE

RS

© 2017 MEI Corporation 521

RECEIVER DRIERS

2 1/2” 8” #6 Male #6 FOR 7600 Top (2) Top Univ. Allows Std or Metric Ftgs R12/R134a3” 8” #6 Male #6 FOR 7600A Top (3) Top Side Univ. Allows Std or Metric Ftgs R12/R134a3” 8” 3/8” #6 3/8” #6 7135 Top (2) 1/4” Side R12/R134a3” 8” 3/8” #6 3/8” #6 7170 Top (2) M10 Top Side (M10 x 1.25mm) R12/R134a3” 8 1/4” 3/8” #6 3/8” #6 7172 Top (2) 1/4” Top Top Peterbilt 18-03638 R123” 10” #6 Male #6 FOR 7600B Top (2) Top Univ. Allows Std or Metric Ftgs R12/R134a3” 10” 3/8” #6 3/8” #6 7160 Top (2) 1/4” Side similar to #7135 R12/R134a3” 10” 3/8” #6 3/8” #6 7169 Top (2) M10 Top R12/R134a4” 7 3/4” 3/8” #6 3/8” #6 7395 R12/R134a

Receiver Drier manufacturers have discontinued using moisture indicators and in some cases sight glases.AirSource will only supply driers with moisture indicators, and sight glass while supply lasts.NOTE

Listed in ascending order by Diameter x Length by Fitting Type and Size (continued).

3” 10” 7/16” #6 3/8” #6 7131 Top Top Top Side 3/16” Charge Port R12/R134a3” 10” 11/16” #6 3/8” #6 7130 Top Top Top alternate #7131 R12/R134a3” 10” 11/16” #6 3/8” #6 7230 Top 16mm Top ParkerType; IHC 1693117C1 R134a4” 9” 3/8” #6 3/8” #6 7396 Ford Tractor E2NN-19825AA R12

3/8” Female O’ring INLET x 3/8” Female O’ring OUTLET

PA

RT

NU

MB

ER

Sigh

t Gla

ss

Switc

h Po

rt

Fuse

Plu

g

Schr

ader

Va

lve

Moi

stur

e In

dica

tor

Pres

sure

R

elie

f Val

ve

Low

Pre

ssur

e Sw

itch

Dia. LENGTH INLET OUTLET Note Charge

3/8” Female O’ring INLET x 3/8” Male O’ring OUTLET

PA

RT

NU

MB

ER

Sigh

t Gla

ss

Switc

h Po

rt

Fuse

Plu

g

Schr

ader

Va

lve

Moi

stur

e In

dica

tor

Pres

sure

R

elie

f Val

ve

Low

Pre

ssur

e Sw

itch

Dia. LENGTH INLET OUTLET Note Charge3” 10” 3/8” #6 3/8” #6 7387 Side Top K251-459,K251-571 R12/R134a3” 10” - - 7577 Top Ford New Holland, 82012480 R12/R134a3” 11 1/2” 3/8” #6 #6 MIO 7573 JDeere, RE214440 R12/R134a3” 11 1/2” 3/8” #6 #6 MIO 7574 JDeere, AL163559 w/bracket R12/R134a4” 7” 3/8” #6 #6 MIO 7575 JDeere, AL162467 w/bracket R12/R134a4” 7” 3/8” #6 3/8” #6 7223 Top R12/R134a4” 7 1/2” 3/8” #6 3/8” #6 7233 (2) Side R12/R134a4” 7 3/4” 3/8” #6 #6 MIO 7572 CASE, 86984155 R12/R134a4” 8 1/2” 3/8” #6 3/8” #6 7597 JDeere w/oe# AZ45582 R12/R134a4” 8 3/4” 3/8” #6 3/8” #6 7392 Side/Top Top JDeere AT162848; AT151981 R12/R134a

3/8” Male O’Ring INLET x 3/8” Female O’Ring OUTLET

Low

Pre

ssur

e Sw

itch

Dia. LENGTH INLET OUTLET Note ChargePA

RT

NU

MB

ER

Sigh

t Gla

ss

Switc

h Po

rt

Fuse

Plu

g

Schr

ader

Va

lve

Moi

stur

e In

dica

tor

Pres

sure

R

elie

f Val

ve

Page 7: Receiver Driers Accumulators, and In-Line Filters Receiver

RE

CE

IVE

R D

RIE

RS

© 2017 MEI Corporation522

RECEIVER DRIERSListed in ascending order by Diameter x Length by Fitting Type and Size (continued).

2 1/2” 6 3/4” #6 Flare #6 Flare 7501 In-Line; 16cu.in.; WAH163 R12/R134a2 1/2” 7” 1/2” Flare 1/2” Flare 7500 In-Line ; WLD164FO; 16cu.in. R12/R134a2 1/2” 8” #6 Flare #6 Flare 7152 Top R12/R134a2 1/2” 8” #6 Flare #6 Flare 7218 Top Top Top w/Low Pressure Sw. R12/R134a3” 6 1/4” #6 Flare #6 Flare 7124 Top Side w/Fuse Plug R12/R134a3” 10” 1/2” Flare 1/2” Flare 7540 In-Line; 30cu.in.; EK304 R12/R134a4” 7 3/4” #6 Flare #6 Flare 7235 Top Side w/Fuse Plug R124” 7” #6 Flare #6 Flare 7211 Top Side w/Fuse Plug R12/R134a

Flare End Fittings - Male INLET and Male OUTLET

PA

RT

NU

MB

ER

Sigh

t Gla

ss

Switc

h Po

rt

Fuse

Plu

g

Schr

ader

Va

lve

Moi

stur

e In

dica

tor

Pres

sure

R

elie

f Val

ve

Low

Pre

ssur

e Sw

itch

Dia. LENGTH INLET OUTLET Note Charge

2 1/2” 6” QD QD 7173 In-Line; Peterbilt 18-03841 R134a2 1/2” 6” QD QD 7176 Top (1) M10 (1) M10 x 1.25mm - Top R12/R134a2 1/2” 6 5/16” 3/8” #6 Course Thrd 7513 Top (1) M10 (1) Top M10 Male; 085623-00 R12/R134a2 1/2” 6 5/16” M18 Fine Thread 7514 Top (1) M10 (1) M10; 33-0382A; 088370-0 R12/R134a2 1/2” 6 5/16” M18 M18 7515 Top (1) M10 (1) M10; 33-0383A; 088371-00 R12/R134a2 1/2” 6 5/16” M18 Fine Thread 7519 Top (1) M10 Motorhome 085686-00 R12/R134a2 1/2” 7 3/4” QD QD 7145 Side Incl. orifice tube; CAT3E3535 R134a3” 9 5/8” QD side QD 60mm 7199 Top (2) M10 ABP N83 319524; 088470-01 R134a3” 10” QD QD 7163 Top (2) 1/4” Top Top 2 Schrader Vlvs (1/4” Top) R134a3” 10” QD QD 7168 Top (2) M10 (2) M10 x 1.25mm (Top) R134a3” 10” QD QD 7179 Top 16mm Top Side R134a Service Port R134a3” 10” QD QD 7386 Side Top R134a4” 8 1/2” QD QD 7236 Top Top Side Side R134a

Quick Disconnect Type

Low

Pre

ssur

e Sw

itch

PA

RT

NU

MB

ER

Sigh

t Gla

ss

Switc

h Po

rt

Fuse

Plu

g

Schr

ader

Va

lve

Pres

sure

R

elie

f Val

ve

Moi

stur

e In

dica

tor

Dia. LENGTH INLET OUTLET Note Charge

PA

RT

NU

MB

ER

Cartridges / Elements

DIA. LENGTH DESCRIPTION Application OE#

Drier Cartridge 6.7L Diesel 7598 Ford F250-550SD BC3Z-19C836A Drier Element 6.2V8 Gas, 6.7L Diesel 7611 Ford F250-550SD BC3Z-19C836B Drier Element 7601 ISUZU 1-83535-097-0 Drier Element - - 7637 drier desiccant bag kit Ford Accumulator Element - - 7636 accumulator desiccant bag kit Ford BK2Z-19C836A

Page 8: Receiver Driers Accumulators, and In-Line Filters Receiver

RE

CE

IVE

R D

RIE

RS

© 2017 MEI Corporation 523

RECEIVER DRIERS

Typical Drier System

Compressor

Evaporator

Suction

Condenser Thermostat

Expansion Valve

Drier

1 3/4” 20 1/2” Male Flare, #6 Male Flare, #6 7622 CAT OE# 1P6541 R134a2 1/2” 6” QD QD 7173 In-Line Drier; Peterbilt 18-03841 R134a2 1/2” 6 3/4” 3/8” #6 Male Flare 3/8” #6 Male Flare 7501 In-Line Drier WAH 163; 16cu.in. R12/R134a2 1/2” 6 3/4” 3/8” #6 Male O’Ring 1/2” #8 Male O’Ring 7140 In-Line Design,GMC R12/R134a2 1/2” 6 3/4” M18 Male O’Ring M20 Male O’Ring 7503 In-Line Drier; GMC 15982368 R12/R134a2 1/2” 7” 1/2” Male Flare 1/2” Male Flare 7500 In-Line Drier; WLD164FO; 16cu.in. R12/R134a2 1/2” 7” 1/2” Flare 1/2” Flare 7504 In-Line Drier; WAH164; 16cu.in. R12/R134a2 1/2” 7 3/4” QD QD 7145 Enclosed Orifice; CAT# 3E3535 R134a2 1/2” 7 3/4” MIO Fitting MIO Fitting 7560 w/Orifice Tube, CAT# 257-3227 R134a2 1/2” 10” 3/8” Male O’Ring 3/8” Male O’Ring 7502 In-Line Drier, RD remote cond. R12/R134a2 1/2” 10 3/4” PAD/ washer #0165 PAD/ washer #0165 7616 CAT OE# 320-0562; 320-0563 (steel) R134a2 1/2” 11” 3/8” #6 Male 1/2” #8 Male 7623 CAT OE# 283-4237; 24M Motor Grader R134a2 5/8” 7 1/2” 3/8” #6 Male 3/8” #6 Female 7562 Side 16 cu.in. desiccant; Kysor 402618 R12/R134a2 3/4” 8 1/2” 1/2” Male Flare 1/2” Male Flare 7542 Side In-Line Drier WSG164FO; 16cu.in R12/R134a2 3/4” 8 1/2” 1/2” #8 MIO 1/2” #8 MIO 7541 Side In-Line Retro; Carrier A/C; 16cu.in. R12/R134a2 3/4” 9 1/2” 1/2” #8 MIO 1/2” #8 MIO 7633 41 cu.in. desiccant; 212028 R134a3” 10” 1/2” Flare 1/2” Flare 7540 In-Line, EK304; 212-010; 30cu.in. R12/R134a3” 10” 1/2” Male Flare 1/2” Male Flare 7548 Side In-Line, Carrier WSG304; 30cu.in R12/R134a3” 10 1/2” 3/8” #6 Male 3/8” #6 Female 7596 Side FNH Backhoe 555E-685E; 85804063 R12/R134a3” 10 1/2” 5/8” Male Flare 5/8” Male Flare 7551 In-Line, Carrier WAH305; 30cu.in. R12/R134a3” 11 1/2” 1/2” #8 MIO 1/2” #8 MIO 7549 Side In-Line, Carrier ADK304; 30cu.in. R12/R134a3 3/4” 10 3/4” 1/2” Male Flare 1/2” Male Flare 7517 In-Line, TransAir AH414; 41cu.in. R12/R134a

PA

RT

NU

MB

ER

Sigh

t Gla

ss

In-Line Filters / Driers

Dia. LENGTH INLET OUTLET Note ChargeMoi

stur

e In

dica

tor

Listed in ascending order by Diameter x Length by Fitting Type and Size (continued).

Page 9: Receiver Driers Accumulators, and In-Line Filters Receiver

RE

CE

IVE

R D

RIE

RS

© 2017 MEI Corporation524

2 3/8” 7 1/2” Pad Type - - 7592 Volvo Exv EC Series, 14509377, R34a3” 8” MIO 5/8” #10 MIO 3/4” #12 7483 M12 Port, 13mm Charge Port, F4TZ-19C836A, F6TZ-19C836AA3 7/16” 9 1/2” Pad - Pad - 7415 M12 Port; Navistar 3542577C2; BOA80-323-00-1393 1/2” 8” FOR M27 MIO M27 7444 (1) M12 Port, GM 1132722, 27249243 1/2” 8” FOR 3/4” #12 FOR 3/4” #12 7406 Universal Type Accumulator; GM 123229923 1/2” 8” Male Pad Female Pad 7584 (1) R143a Charge Port, (1) M12 Switch Port ; 14118123 1/2” 8 1/8” MIO 5/8” #10 MIO 3/4” #12 7493F, G F6HZ-19C936A; 4C4H-19C808AA3 1/2” 8 3/4” Male SL 5/8” #10 Male SL 3/4” #12 7482 (1) M10 Switch Port, (1) Chg Port 13mm; F4UZ-19C836A3 1/2” 8 3/4” FIOR #12 1-1/16”-16 FIOR #12 1-1/16”-16 7543 w/o desiccant, Caterpillar 101-8789, 700001, 151-5261 (steel)3 1/2” 8 7/8” Pad Type #0154 - - 7496A Ford F250/350, 6C3Z-19C836A3 1/2” 8 7/8” Pad Type #0154 FIOR 3/4” #12 7496 F81Z-19C 836AA3 1/2” 9” FIOR 1/2” #8 FIOR 3/4” #12 7486 Ford F9UZ-19C1836AB; F65Z-19C836AA3 1/2” 9” FIOR 5/8” Male SL 3/4” 7495 Ford E-Series, 2C2Z-19C836BA3 1/2” 9” FOR 3/4” #12 MIO 3/4” #12 7431 (2) 1/4” Ports; 1131506, 3059317, 272483363 1/2” 9” FOR 3/4” #12 MOR 3/4” #12 7450 (2) Serv Ports; 1131404, 2724266, 2724199, 27248043 1/2” 9” FOR 3/4” #12 MIO 3/4” #12 7459 (2) 1/4” Ports; GM 1131475, 2724877, 3057034, 30582623 1/2” 9” FOR M27 MIO M27 7430 w/M12 Port, 13mm R134a Port; 2724885, 27246653 1/2” 8” FOR 3/4” #12 MOR 3/4” #12 7434 (1) 1/4” Port,w/R134a Port, R12 Port; 1131843; 27246893 1/2” 9” FOR M27 MOR M27 7446 (1) M12 Port, GM 27248173 1/2” 9” FOR M27 MOR M27 7440 (1) M12 Port (1) M13 Port, GM 27248473 1/2” 9” FOR 3/4” #12 MIO 3/4” #12 7448 (2) 1/4” Port, GM 27241943 1/2” 9” FOR 3/4” #12 MIO 3/4” #12 7466 w/M12 Port 1 3/4” below Fittings, GM 27244753 1/2” 9” FOR M27 MIO M27 7466M w/M12 Port 1 3/4” below Fittings, GM 27248993 1/2” 9” FOR M27 MIO M27 7469 (1) M12 Port (1) 13mm Port, GM 27248863 1/2” 9” Pad Type Pad MIO M27 7457 (1) M12 Port (1) 13mm Port, GM 150053713 1/2” 9” Male SL 3/4” #12 Female SL #10 & #12 7383 (2) 1/4” Ports, E69Z-19C836B3 1/2” 9” Male SL 3/4” #12 Female SL 3/4” #12 7485 (1) M12 Port (1) M13 Port, Ford E49Z-19C836C3 1/2” 9” Male SL 5/8” #10 FOR & Pad Pad Type 7494 Ford XL3Z-19C836BA3 1/2” 9” Male SL - FIOR - 7488 Ford F7UZ-19C836BB3 1/2” 9” Male SL #0154 FOR & Pad PAD 7490 Ford XL3Z-19C836AA3 1/2” 9” Female SL 5/8” #10 MIOR #10 5/8” #10 7487 Ford E75Z-19C836AA3 1/2” 9” Female SL 5/8” MIO 5/8” 7489 Ford F75Z-19C836BA3 1/2” 9 1/8” FOR #12, 1-1/16” FOR #12, 1-1/16” 7409 Peterbilt 18-038373 1/2” 9 1/8” Pad Type - - Pad Type 7408 Peterbilt 18-04171; 7000753 1/2” 9 3/4” MIO 3/4” #12 Female SL 3/4” #12 7479 (2) 1/4” Ports; Ford E6VY-19C836A3 1/2” 9 3/4” FOR #12 (1/16”-16) FOR #12 (1/16”-16) 7595 CAT 186-61893 1/2” 9 3/4” FIOR #12 1-1/16”-16 FIOR #12 1-1/16”-16 7544 w/desiccant, Caterpillar 089320-00, 197-62183 1/2” 10” Pad - Stat Seal #12, #0142 7558 M12-1.5 Sw Port, GMC G Series 2003-08, 257608293 1/2” 10” Pad Type #0142 PAD #0142 7554 Topkick/Kodiak 1132813 (#12 Stat Seal)3 1/2” 10” MOR 3/4” #12 MOR 3/4” #12 7369 (2) R12 Ports, Ford E1VY-19C836A3 1/2” 10” Female SL 3/8” #6 Female SL 5/8” #10 7162 Two (2) Schrader Valves: Top/Side3 1/2” 10” MIO 5/8” #10 MIO 3/4” #12 7454 (2) 1/4” Ports, Ford E3TZ-19C836B, E7TZ-19C836A3 1/2” 11” FIOR 5/8” FIOR 3/4” 7552 w/ diesel eng., Ford E-Series, 7C2Z-19C836AA3 1/2” 11” FIOR 5/8” PAD #0017M 7583 Ford E-Ser. 7C2Z-19C836B3 1/2” 12.3” MOR 7/8” MOR 7/8” 7385 M12 switch port, R134a Charge Port, F4HZ-19C836A3 1/2” - Bead ftg. #6 PAD PAD 7416 08 Navistar Prostar 3666273-C1, 3670134-C13 1/2” - Bead ftg. #6 PAD PAD 7417 Navistar Prostar 3670134-C1. P65460013 1/2” - Pad Type #0154 #0017M #12 7578 08 Ford 8C3Z-19C836C (switch #1418)

Listed in ascending order by Diameter x Length by Fitting Type and Size.

NotePA

RT

NU

MB

ER

Inlet Size

Outlet Size

Outlet Type

Inlet TypeLength

Accumulators

Dia.

FIOR = Female Insert O’ringFOR = Female O’ringMIO = Male Insert O’ringMOR = Male O’ringSL = Springlock

ACCUMULATORS / RECEIVER DRIERS

© 2017 Chad/Preston

Page 10: Receiver Driers Accumulators, and In-Line Filters Receiver

RE

CE

IVE

R D

RIE

RS

© 2017 MEI Corporation 525

RECEIVER DRIERS / ACCUMULATORS

3 1/2” - - - - - call GMC 04-06 Silverado 14116463 1/2” - - - - - call GMC 01-05 Silverado Avalanche 14116473 1/2” - FIOR 5/8” MIO 5/8” 7576 J. Deere 670D Grader AT190809, 803-4653 1/2” - Stat Seal #12 Stat Seal #12 call GMC 01-05 Silverado Avalanche 14116484” 8 1/2” PAD, Top - PAD, Top - 7628 CAT 320-0564 (steel)4” 9 5/8” PAD, Front - PAD, Front - 7627 CAT 308-2583 (steel)4” 10 1/4” PAD - FIOR 3/4” #12 7498 (2) 13mm Ports, M10 Switch Port; F85Z-19C 836AB13 1/4” 7 1/2” PAD - Female SL 3/4” #12 7588 13mm Charge Port, Ford Transit-conn. 9T1Z-19C836A: YF3625- - - - - - 7636 Ford/Sterling, Transit Van, desiccant bag kit; BK2Z-19C836A

NotePA

RT

NU

MB

ER

Inlet Size

Outlet Size

Outlet Type

Inlet TypeLengthDia.

Compressor

Accumulator

Evaporator

Condenser

Thermostat

Orifice Tube

Typical Accumulator System

Listed in ascending order by Diameter x Length by Fitting Type and Size (continued).

CCOT - Clutch Cycling Orifice Tube

Accumulators (continued)

FIOR = Female Insert O’ringFOR = Female O’ringMIO = Male Insert O’ringMOR = Male O’ringSL = Springlock

Page 11: Receiver Driers Accumulators, and In-Line Filters Receiver

RE

CE

IVE

R D

RIE

RS

© 2017 MEI Corporation526

RECEIVER DRIERS

3/8” male thread

1/2”-20 thread

3/8” female thread

Moisture Indicator Bus Applications with In-line Drier

4160Moisture Indicator Bus Applications with In-line Drier1/2” Male Flare x 1/2” Female Flare SAE

4139Quick Disconnect Coupler For All Quick Disconnect Type Driers3/8” Male Insert x Q.D.2-1/4” length (1 per box)

4971K Quick Disconnect Coupler Assembly1/2”-20 thread (includes Valve Kit)fits Motorhome driers; receiver drier #7513

4138Quick Disconnect Coupler For IHC Applications 3/8” Female x Q.D. (1 per box)

7473Heavy Duty Compact BracketFor driers up to 4” in diameter

Drier Brackets – Universal

7472Heavy Duty Drier BracketFor driers 3” in diameter

7471Universal Drier BracketFor driers 2 1/4” to 3” in diameter

Quick Disconnect Couplers

Available while

supply lasts

4971VKQuick Disconnect Valve Repair Kit Fits # 4971K Coupler (fits Motorhomes)

Page 12: Receiver Driers Accumulators, and In-Line Filters Receiver

RE

CE

IVE

R D

RIE

RS

© 2017 MEI Corporation 527

RECEIVER DRIERSNOTE: Drier mfg’s have discontinued using moisture indicators. We will supply moisture indicators where applicable while supply lasts. #6 = 3/8” #8 = 1/2” #10 = 5/8” #12 = 3/4”

7127Dia. - 3”Lgth. - 6 1/2”In/Out - 3/8” x 3/8” Male O’ringTop Sight GlassSide Binary Switch, Fuse Plug

7128Dia. - 3”Lgth. - 6 1/2”In/Out - 3/8” x 3/8” Male O’ringTop Sight GlassSide Trinary Switch, Fuse Plug

OUT OUTIN IN

IN OUT

INOUT

7123Dia. - 3”Lgth. - 6 1/2”In/Out - 3/8” Male O’ringTop Sight GlassSide Male Switch Port P.R.V. & Moisture Indicator

7129Dia. - 3”Lgth. - 6”In/Out - 3/8” x 3/8” Male O’ringTop Sight Glass, Fuse Plug

OUTIN

7118Dia. - 2 1/2”Lgth. - 8”3/8” x 3/8” Male O’ringTop Sight GlassFemale Switch Port 1/4” Male Switch PortFreightliner A22-14425-2; 085268-03

7119Dia. - 2”Lgth. - 8 1/2”In/Out - #6 Male Insert O’ringsTop Sight Glass R12 Ports (2)Multi fit applications

OUTIN

7120Dia. - 2 1/2”Lgth. - 8”In/Out - 3/8” x 3/8” Male O’ringTop Sight GlassLow Pressure Switch 1/4” Male Switch Port

OUT

OUT

OUT

IN

IN

IN

7124Dia. - 3”Lgth. - 6 1/4”In/Out - 3/8” x 3/8” Male FlareTop Sight Glass, Fuse Plug

OUTIN

7125Dia. - 3”Lgth. - 6”In/Out - 3/8” Male O’ringTop Sight GlassSide Female Switch PortHigh Pressure Reliev Valve

OUTIN

#1430switch

7126Dia. - 3”Lgth. - 6 1/2”In/Out - 3/8” Male O’ringTop Sight GlassSide Male 1/4” Schrader Valve High Pressure Relief Valve

7122DrierDia. - 2-1/2”Lgth. - 8”3/8” x 3/8” Male O’ringSight GlassFuse Plug1/4” NPT FtgThermo King Tri-Pac Unit #61-3552

INOUT

1/4” NPT

7126D Universal Application (steel)Dia. - 2-3/4”Lgth. - 6”In/Out - #6 Male Insert O’ringSide 3/8” Male PortSide 3/8” Female PortTop Sight Glass

# 0011#6 o’rings

Page 13: Receiver Driers Accumulators, and In-Line Filters Receiver

RE

CE

IVE

R D

RIE

RS

© 2017 MEI Corporation528

RECEIVER DRIERSNOTE: Drier mfg’s have discontinued using moisture indicators. We will supply moisture indicators where applicable while supply lasts. #6 = 3/8” #8 = 1/2” #10 = 5/8” #12 = 3/4”

7135Dia. - 3” Lgth. - 8”In - 3/8” Male O’ringOut - 3/8”Female O’ringTop Sight Glass(2) Schrader ValvesPressure Relief Valve

7140Dia. - 2 1/2”Lgth. - 6 3/4” In - 3/8” Male O’ringOut - 1/2” Male O’ringIn-Line Design, GMC

7134Dia. - 3”Lgth. - 10”In/Out - 3/8” x 3/8” Male O’ringTop Sight GlassTop Switch PortMoisture IndicatorPressure Relief ValveKenworth K251-566

7145Dia. - 2 1/2”Lgth. - 7 3/4” (13.88” OAL)Quick DisconnectEnclosed Orifice TubeR134a OnlyCAT 3E3535

7152Dia. - 2 1/2”Lgth. - 8”In/Out - 3/8” x 3/8” Male FlareTop Sight Glass

OUTIN

OUT

OUT

IN

IN

OUTIN

IN OUT

7143Dia. - 3”Lgth. - 10”In/Out - 3/8” x 3/8” Male O’ringTop Sight Glass, Schrader ValveFuse Plug, Moisture Indicator

7133Dia. - 3”Lgth. - 8 1/4”In/Out - 3/8” x 3/8” Male O’ringTop Sight GlassFemale Switch PortPressure Relief Valve

OUTIN

IN

IN

OUT

OUT

OUTIN

7141Dia. - 3”Lgth. - 8 1/4”In/Out - 3/8” x 3/8” Male O’ringSide Sight Glass, Top Switch Port

IN OUTIN OUT

7132Dia. - 3”Lgth. - 10”In/Out - 3/8” x 3/8” Male O’ringSide Sight GlassTop Schrader ValveMoisture IndicatorFuse Plug Relief Valve

7131Dia. - 3”Lgth. - 10”In - 7/16” Female O’ringOut - 3/8” Female O’ringTop Sight GlassCharge Port 3/16”Moisture Indicator; PRV

7130Dia. - 3”Lgth. - 10”In - 11/16” Female O’ringOut - 3/8” Female O’ringTop Sight GlassPressure Relief Valve

OUTIN

7153 Universal Application (steel)Dia. - 2-3/4”Lgth. - 10”In/Out - #6 Male Insert O’ringSide 3/8” Male PortSide 3/8” Female PortTop 3/8” Male PortTop Sight Glass

# 0011#6 o’rings

Page 14: Receiver Driers Accumulators, and In-Line Filters Receiver

RE

CE

IVE

R D

RIE

RS

© 2017 MEI Corporation 529

RECEIVER DRIERSNOTE: Drier mfg’s have discontinued using moisture indicators. We will supply moisture indicators where applicable while supply lasts. #6 = 3/8” #8 = 1/2” #10 = 5/8” #12 = 3/4”

OUT IN

1550

7157Dia. - 2 3/4”Lgth. - 10”In/Out - 3/8” x 3/8” Male O’ringTop Sight GlassSide Trinary Switch

7159Dia. - 3”Lgth. - 9”In/Out - 3/8” x 3/8” Male O’ringTop Sight GlassTop Schrader ValveMoisture IndicatorPressure Relief Valve

7160Dia. - 3”Lgth. - 10”In - 3/8” Male O’ringOut - 3/8” Female O’ringTop Sight Glass(2) Schrader ValvesPressure Relief ValveABPN83-319714

OUTIN

7163Dia. - 3”Lgth. - 10”Quick DisconnectTop Sight Glass(2) 1/4” Schrader ValvesHigh Pressure Relief ValveMoisture Indicator; R134a Only

OUTINOUTIN

7162Accumulator Dia. - 3 1/2”Lgth. - 10”In - 3/8” Female SpringlockOut - 5/8” Female Springlock (2) Schrader Vlv (Top/Side)

OUT IN

OUTIN

7161Dia. - 3”Lgth. - 8”In/Out - 3/8” x 3/8” Male O’ring(2) Schrader Valves

7165Dia. - 3”Lgth. - 10”In/Out - 3/8” x 3/8” Male O’ringTop Sight GlassSchrader ValveMoisture IndicatorPressure Relief Valve

7164Dia. - 3”Lgth. - 9”In/Out - 3/8” x 3/8” Male O’ringTop Sight GlassSide Switch Port (1/8”-27 NPT)Moisture IndicatorPressure Relief Valve088254-01

7156Dia. - 2 3/4”Lgth. - 10”In/Out - 3/8” x 3/8” Male O’ringTop Sight GlassSide Switch PortPressure Relief Valve

IN OUT

7155Dia. - 2 3/4”Lgth. - 10”In/Out - 3/8” x 3/8” Male O’ringTop Sight GlassSide 1/4” Schrader ValvePressure Relief ValveMack 221RD328

IN OUT

7155BDia. - 2 3/4”Lgth. - 10”3/8” x3/8” Male O’’Ring with Male Switch Port, Fuse Plug, Top Sight GlassSupplied w/Binary Switch #1510Mack 221RD327

7154Dia. - 2 3/4”Lgth. - 10”In/Out - 3/8” x 3/8” Male O’ringTop Sight GlassSide Low Pressure Switch

IN OUT

Page 15: Receiver Driers Accumulators, and In-Line Filters Receiver

RE

CE

IVE

R D

RIE

RS

© 2017 MEI Corporation530

RECEIVER DRIERSNOTE: Drier mfg’s have discontinued using moisture indicators. We will supply moisture indicators where applicable while supply lasts. #6 = 3/8” #8 = 1/2” #10 = 5/8” #12 = 3/4”

7185Dia. - 3”Lgth. - 9”3/8” x 3/8” Male O’ringInlet - Right AngleMoisture IndicatorPressure Relief Valve

7180Dia. - 3”Lgth. - 8”In/Out - 3/8” x 3/8” Male O’ring(2) Schrader Valves - M10 PH088340-01

OUTIN

7173In-Line Drier - R134a OnlyDia. - 2 1/2”Lgth. - 6” (9.6” overall)Quick Disconnect Peterbilt OE# 18-03841

7174Dia. - 3”Lgth - 9”In/Out 3/8” x 3/8” Male O’ringPressure Relief ValveMoisture Indicator OE# 20407203

7175Dia. - 3”Lgth. - 10”In/Out - 3/8” x 3/8” MaleSide Sight Glass 1/4” Female PortHigh Pressure Relief ValveKenworth OE# K251-459

7179Dia. - 3”Lgth. - 10”Quick DisconnectTop Sight GlassMoisture IndicatorPressure Relief ValveR134a Service Port, 16mm

7176Dia. - 2 1/2”Lgth - 6”Quick DisconnectTop Sight Glass(1) Schrader Valve - M10

OUTIN

IN

INOUT

7172Dia. - 3’”Lgth. - 8 1/4”In - 3/8” Male O’ringOut - 3/8” Female O’ringTop Sight GlassHigh Pressure Relief ValveMoisture Indicator(2) Schrader Valves - R12 Only

OUTIN

OUT

IN

IN

OUT

OUT

IN

OUT

7169Dia. - 3” Lgth. - 10”In - 3/8” Male O’ringOut - 3/8” Female O’ringTop Sight Glass(2) Schrader Valves - M10

7170Dia. - 3”Lgth. - 8”In - 3/8” Male O’ringOut - 3/8” Female O’ringTop Sight GlassPressure Relief ValveMoisture Indicator(2) Schrader Valves - M10

OUTIN

INOUT

7168Dia. - 3”Lgth. - 10”Quick DisconnectTop Sight Glass(2) Schrader Valves - M10R134a Only

IN

OUT

7166Dia. - 3”Lgth. - 10”In/Out 3/8” x 3/8” Male O’ringTop Sight GlassPressure Relief ValveMoisture IndicatorMetric Schrader Valve - M10

OUT IN

Page 16: Receiver Driers Accumulators, and In-Line Filters Receiver

RE

CE

IVE

R D

RIE

RS

© 2017 MEI Corporation 531

RECEIVER DRIERSNOTE: Drier mfg’s have discontinued using moisture indicators. We will supply moisture indicators where applicable while supply lasts. #6 = 3/8” #8 = 1/2” #10 = 5/8” #12 = 3/4”

7197Dia. - 3”Lgth. - 10”In/Out - #6 Slimline Slimline use #0126 seals(2) M10 Switch PortsPressure Relief PlugABPN83-319744

7198 Dia. - 3”Lgth. - 10 1/4”In/Out - 3/8” x 3/8”Slimline use #0126 sealsMoisture Indicator(2) M10 Switch PortsR134a OnlyABPN83-319534

# 0126seals

OUTIN

# 0126seals

IN

OUT

7211Dia. - 4”Lgth. - 7”In/Out - 3/8” x 3/8”Male FlareTop Sight GlassFuse Plug

7218Dia. - 2 1/2”Lgth. - 8”In/Out - 3/8” x 3/8” Male FlareTop Sight GlassTop Schrader ValveLow Pressure Switch

OUTIN

7223Dia. - 4”Lgth. - 7”In - 3/8” Female O’ringOut - 3/8” Male O’ringTop Sight Glass

OUTOUT

ININ

7229Dia. - 3”Lgth. - 8 1/2”In/Out 3/8” x 3/8” Male O’ringTop Sight GlassMale Schrader PortFemale Switch Port

7232Dia. - 4”Lgth. - 7”In/Out - 3/8” x 3/8” Male O’ring(opposite side inlet)Top Sight GlassSide Fuse PlugMoisture Indicator

OUTOUT

ININ

7199Dia. - 3”Lgth. - 9 5/8”In - QD (side)Out - QD (top)(2) M10 Ports, Sight GlassQuick Disconnect - 60mm (2-3/8”)ABPN83-319524; 088470-01

7230Dia. - 3”Lgth. - 10”In - 11/16” Female O’ringOut - 3/8” Female O’ringTop Sight GlassPressure Relief Valve16mm Service Port; R134a Only

7189Dia. - 3”Lgth. - 10”In/Out - 3/8” x 3/8” Male O’ringTop Sight Glass

7190Dia. - 3”Lgth. - 10”In/Out - 3/8” x 3/8”Male O’ringTop Sight GlassMoisture Indicator

IN OUT

7193Dia. - 3”Lgth. - 10”In - 3/8” Male O’ringOut - 3/8” Male O’ringTop Sight Glass Fuse Plug, (1) 1/4” PortMoisture IndicatorWestern Star

OUTININ OUT

Page 17: Receiver Driers Accumulators, and In-Line Filters Receiver

RE

CE

IVE

R D

RIE

RS

© 2017 MEI Corporation532

RECEIVER DRIERSNOTE: Drier mfg’s have discontinued using moisture indicators. We will supply moisture indicators where applicable while supply lasts. #6 = 3/8” #8 = 1/2” #10 = 5/8” #12 = 3/4”

OUT IN

OUT

IN

7383Accumulator FordDia. - 3 1/2” Lgth. - 9”In - 3/4” Male SpringlockOut - 3/4” and 5/8” Female Springlock(2) 1/4” PortsOE# E69Z-19C836B

7236Dia. - 4”Lgth. - 8 1/2”Quick DisconnectTop Sight GlassMoisture IndicatorLow Pressure SwitchPressure Relief Valve; R134a Only

7346Dia. - 3”Lgth. - 9 3/4”In/Out - 3/8” x 3/8” Male O’ring Sight Glass

7369Accumulator FordDia. - 3 1/2”Lgth. - 10”In - 3/4” Male O’ringOut - 3/4” Male O’ring(2) R12 PortsOE# E1VY-19C836A

7387Dia. - 3”Lgth. - 10”In - 3/8” Female O’ringOut - 3/8” Male O’ringMoisture IndicatorSide Sight GlassKenworth K251-571

OUT

INOUT

IN

7385AccumulatorDia. - 3 1/2”Lgth. - 12.3”In/Out - 7/8” Male O’ringM12 Switch PortR134a Charge PortOE# 089248-00; F4HZ-19C836A

7386Dia. - 3”Lgth. - 10”Quick DisconnectSide Sight GlassMoisture Indicator; R134a Only

IN OUT

7235Dia. - 4”Lgth. - 7 3/4”In/Out - 3/8” x 3/8”Male FlareTop Sight GlassFuse Plug, R12

7234Dia. - 4”Lgth. - 8 1/2”In/Out - 3/8” x 3/8”Male Insert O’ringCombo: Sight Glass and Moisture Indicator,Low Pressure Switch Port Sided Fuse PlugCAT 5V5698, 8P9991

7233Dia. - 4”Lgth. - 7 1/2”In - 3/8” Female O’ringOut - 3/8” Male O’ring(2) Side Sight Glass

IN

IN

OUT

OUT

OUTIN

7388Dia. - 2 3/4”Lgth. - 10”In/Out - 3/8” x 3/8” Male O’ringSide Sight GlassTop Switch PortPressure Relief ValveKenworth K251-263

7389Dia. - 2 3/4”Lgth. - 10”In/Out - 3/8” x 3/8” Male O’ringSide Sight GlassTop Schrader ValvePressure Relief ValveIHC OE# 1691600C92

OUTIN

Page 18: Receiver Driers Accumulators, and In-Line Filters Receiver

RE

CE

IVE

R D

RIE

RS

© 2017 MEI Corporation 533

RECEIVER DRIERSNOTE: Drier mfg’s have discontinued using moisture indicators. We will supply moisture indicators where applicable while supply lasts. #6 = 3/8” #8 = 1/2” #10 = 5/8” #12 = 3/4”

IN

OUT

7400Side: Sight GlassBottom: High Press SwitchTop: Moisture IndicatorCarrier CM2 / CM365-00193-00; 088599-01

7406Universal Accumulator Dia. - 3 1/2”Lgth. - 8”In - 3/4” #12 Female O’ringOut - 3/4” #12 Female O’ring(2) R12 PortsGM 12322992

7395Dia. - 4”Lgth. - 7 3/4”In - 3/8” Male O’ringOut - 3/8” Female O’ring

IN OUT

# 0011 o’rings

7396Dia. - 4”Lgth. - 6”Horizontal TypeIn - 3/8” Female Piloted O’ring FittingOut - 3/8” Female Piloted O’ring Fitting

7397Dia. - 3”Lgth. - 11”Pad Manifold Fittings330, 340, 387 SeriesPeterbilt F37-6002

7399Dia. - 3”Lgth. - 11”Pad Manifold FittingsPeterbilt F37-6009

7398Dia. - 3”Lgth. - 11”Pad Manifold Fittings365 thru 389 SeriesPeterbilt F37-6003

7393Dia. - 3”Lgth. - 11”Manifold Connection Type R134a OnlyKenworth T2000, F37-6000

7392Dia. - 4”Lgth. - 8 3/4”In - 3/8” Female O’ringOut - 3/8” Male O’ringTop Sight Glass andSide Sight GlassMoisture IndicatorJ Deere AT151981, AT162848

7394Dia. - 4”Lgth. - 6 1/2” In/Out - 3/8” x 3/8” Male O’ringTop Sight Glass

IN OUT

7391Dia. - 4”Lgth. - 7 3/4”In/Out - 3/8” x 3/8” Male O’ringTop Sight GlassMoisture IndicatorSide Low Pressure SwitchPressure Relief Valve; R134a Only

7390Dia. - 2 3/4”Lgth. - 10”In/Out - 3/8” x 3/8” Male O’ringSide Sight GlassTop Trinary SwitchPressure Relief Valve

IN OUT

IN

IN

IN

Page 19: Receiver Driers Accumulators, and In-Line Filters Receiver

RE

CE

IVE

R D

RIE

RS

© 2017 MEI Corporation534

RECEIVER DRIERSNOTE: Drier mfg’s have discontinued using moisture indicators. We will supply moisture indicators where applicable while supply lasts. #6 = 3/8” #8 = 1/2” #10 = 5/8” #12 = 3/4”

7416Drier Assy.2008 Navistar Prostar 3666273-C1

# 0137 suction o’ring

M12

# 0139suction flange gasket

7417Drier Assy.Navistar Prostar 3670134-C1, P6546001

7418Drier (steel)Dia. - 3”Lgth. - 9”Slimline Pad FittingsMACK Freedom ClassOE# 5010463763

OUT

OUT

IN

7415Dia. - 3 7/16”Lgth. - 9 1/2”Pad Mount Accumulator(1) M12 PortNavistar 3542577C2;BOA80-323-00-139

# 0136discharge o’ring

# 0138discharge flange gasket

# 0011#6 o’ring

# 0011#6 o’ring

# 0136discharge o’ring

# 0138discharge flange gasket

# 0017 o’rings

# 0131 seals

# 0130# 0131 stat seals

7408Accumulator Dia. - 3 1/2”Lgth. - 9 1/8”uses (2) #0017 O’rings and #4589SR fittingPeterbilt Pad 18-04171

7409Dia. - 3 1/2”Lgth. - 9 1/8”In/Out: 1-1/16” #12 Female O’ringPeterbilt 18-03837

7411Dia. - 3”Lgth. - 11”PAD type DrierPeterbilt F37-10191000538099BSM

7419Dia. - 3”Lgth. - 9”In/Out - 3/8” x 3/8” Male O’ring Moisture IndicatorMack 221RD44M

7420Pad Mount Drier Dia. - 2-3/8”Lgth. - 9” (2) 3/8” x 24 Female Sw PortsJ Deere ExcavatorsOE# 4448179; 464699

uses:#0156o’ring/gasket kit#1400 sensor

uses:#0155o’ring/gasket kit

uses:#0155o’ring/gasket kit

7414Dia. - 3”Lgth. - 11”In/Out - 1/2” #8 Pad FittingsKenworth OE# F37-6017

7412 PAD type Drier - SteelDia. - 3”Lgth. - 10 5/8”PACCAAROE# F37-1017-100

7413 PAD type Drier - SteelDia. - 3”Lgth. - 10 5/8”PACCAAROE# F37-1017-200

Page 20: Receiver Driers Accumulators, and In-Line Filters Receiver

RE

CE

IVE

R D

RIE

RS

© 2017 MEI Corporation 535

RECEIVER DRIERSNOTE: Drier mfg’s have discontinued using moisture indicators. We will supply moisture indicators where applicable while supply lasts. #6 = 3/8” #8 = 1/2” #10 = 5/8” #12 = 3/4”

7448Accumulator GMDia. - 3 1/2”; Lgth. - 9”In - 3/4” Female O’ring Out - 3/4” Male Insert O’ring (2) 1/4” PortsOE# 2724194

IN OUTIN

OUT

7450Accumulator GMDia. - 3 1/2”; Lgth. - 9”In - 3/4” Female O’ring Out - 3/4” Male O’ring (2) 1/4” PortsOE# 2724804

7454Accumulator FordDia. - 3 1/2”; Lgth. - 10”In - 5/8” Male Insert O’ring Out - 3/4” Male Insert O’ring (2) 1/4” PortsOE# E7TZ-19C836A

IN

OUT

INOUT

7446Accumulator GMDia. - 3 1/2”; Lgth. - 9”In -M27 Female O’ring Out -M27 Male O’ring (1) M12 PortOE# 2724817

7444Accumulator GMDia. - 3 1/2”; Lgth. - 8”In -M27 Female O’ringOut -M27 MIO(1) M12 PortOE# 1132722; 2724924

7440Accumulator GMDia. - 3 1/2”; Lgth. - 9”In -M27 Female O’ringOut -M27 Male O’ring(1) M12 Port; (1) M13 R134a PortOE# 2724847

IN

OUT

OUTINOUT IN

7434Accumulator GMDia. - 3 1/2”; Lgth. - 8”In - 3/4” Female O’ringOut- 3/4” Male O’ring(1) 1/4” PortOE# 1131843; 2724542; 2724689

7431Accumulator GMDia. - 3 1/2”; Lgth. - 9”In - 3/4” Female O’ringOut - 3/4” Male Insert O’ring(2) 1/4” PortsOE# 1131506; 3059317

OUT IN

7430Accumulator GMDia. - 3 1/2”; Lgth. - 9”In - M27 x 2 5/8” Female O’ringOut - M27 x 2 5/8” Male Insert O’ring(1) M12 Port; (1) M13 R134a PortOE# 2724665; 2724885

uses:#0160o’ring/gasket kit

7422Drier w/Aux AC, 3 Ports International 4000, 7000, 8000 Series OE#: 3843558-C92

uses:#0155 & #0160o’ring/gasket kit

7421Drier w/o Aux AC, 2 ports International 4000, 7000, 8000 SeriesOE#: 3839360-C92

7424Drier (steel)Dia. - 3”Lgth. - 10-5/8”In/Out - Pad FittingsKenworth OE# F37-1021

Page 21: Receiver Driers Accumulators, and In-Line Filters Receiver

RE

CE

IVE

R D

RIE

RS

© 2017 MEI Corporation536

RECEIVER DRIERSNOTE: Drier mfg’s have discontinued using moisture indicators. We will supply moisture indicators where applicable while supply lasts. #6 = 3/8” #8 = 1/2” #10 = 5/8” #12 = 3/4”

7487Accumulator FordDia. - 3 1/2”Lgth. - 9”In - Female SL #10Out - MIOR #10OE# F75Z-19C836AA

7486Accumulator FordDia. - 3 1/2”Lgth. - 9”In - 1/2” #8 Female Insert O’ringOut - 3/4” #12 Female Insert O’ringOE# F65Z-19C836AA

7485Accumulator FordDia. - 3 1/2”Lgth. - 9”In - 3/4” Male SpringlockOut - 3/4” Female Springlock(1) M12 Port(1) M13 R134a PortOE# E49Z-19C836C

7459Accumulator GMDia. - 3 1/2”; Lgth. - 9”In - 3/4” Female O’ring Out - 3/4” Male Insert O’ring (2) 1/4” PortsOE# 2724877

IN

OUT

IN

OUT

7469Accumulator GMDia. - 3 1/2”Lgth. - 9” In - M27 Female O’ring Out - M27 Male Insert O’ring (1) M12 Port; (1) 13mm R134a PortOE# 2724886

IN

OUTINOUT

7479Accumulator FordDia. - 3 1/2”Lgth. - 9 3/4”In - 3/4” Male Insert O’ring Out - 3/4” Female Springlock(2) 1/4” PortsOE# E6VY-19C836A

7466Accumulator GMDia. - 3 1/2”Lgth. - 9”In - 3/4” Female O’ring Out - 3/4” Male Insert O’ring (1) M12 Port (1 3/4” below fittings)OE# 2724475

7466MAccumulator GMDia. - 3 1/2”Lgth. - 9”In - M27 Female O’ring Out - M27 Male Insert O’ring (1) M12 Port (1 3/4” below fittings)OE# 2724899

OUTIN

7480Dia. - 2 1/2”Lgth. - 8 1/4”In/Out - 3/8” x 3/8” Male O’ring Switch Port

7482Accumulator FordDia. - 3 1/2”Lgth. - 8 3/4”In - 5/8” #10 Male SpringlockOut - 3/4” #12 Male Springlock(1) M10 Switch Port (1) 13mm Chg Port OE# F4UZ-19C836A

7483Accumulator FordDia. - 3”Lgth. - 8”In - 5/8” Male Insert O’ring Out - 3/4” Male Insert O’ring M12 Switch Port13mm Charge PortOE# F4TZ-19C836A; F6TZ-19C836AA

# 0142seals

7457Accumulator GMDia. - 3 1/2”; Lgth. - 9”In - Pad TypeOut - M27 Male Insert O’ring (1) M12 Port(1) 13mm R134a PortOE# 15005371

#0015o-ring

#0013o-ring

#0015o-ring

#0017o-ring

Page 22: Receiver Driers Accumulators, and In-Line Filters Receiver

RE

CE

IVE

R D

RIE

RS

© 2017 MEI Corporation 537

RECEIVER DRIERSNOTE: Drier mfg’s have discontinued using moisture indicators. We will supply moisture indicators where applicable while supply lasts. #6 = 3/8” #8 = 1/2” #10 = 5/8” #12 = 3/4”

7501Dia. - 2 1/2”Lgth. - 6 3/4”In/Out - 3/8” x 3/8” Male Flare 16 cu.in. desiccantIn-Line Filter DrierOE# WAH163

use # 0170special o’rings (not supplied)

7500Dia. - 2 1/2”Lgth. - 7” In/Out - 1/2” x 1/2” Male Flare16 cu.in. desiccant In-Line Filter DrierOE# WAH164FO

IN

OUT

7498Accumulator FordDia. - 4”Lgth. - 10 1/4”In - PADOut - 3/4” Female Insert O’ringM10 Switch Port(2) 13mm Charging Ports OE# F85Z-19C836AB

7495Accumulator Dia. - 3-1/2”Lgth. - 9”In - 5/8”FIOROut - 3/4” Male SLFord Truck E SeriesOE# 2C2Z-19C836BA

PlP

Must reuse old housing and switch or use #7496A which includes the housing and switch.

# 0154pad o’ring# 0017o’ring

# 0154pad o’rings7496

Accumulator FordDia. - 3 1/2”Lgth. - 8 7/8”In - PADOut - 3/4” #12 Female Insert O’ringOE# F81Z-19C836AA

7496AAccumulator Dia. - 3 1/2”Lgth. - 8 7/8”Ford F250/350OE# 6C3Z-19C836A

7494Accumulator FordDia. - 3-1/2”Lgth. - 9”In - Male SL #10Out - PADOE# XL3Z-19C836BA

7493GAftermarket StyleFord AccumulatorDia. - 3 1/2”Lgth. - 8 1/8”In - 5/8” #10 MIOOut - 3/4” #12 MIOOE# F6HZ-19C836A

7493FO.E. Style Ford AccumDia. - 3 1/2”Lgth. - 8 1/8”In - 5/8” #10 MIO Out - 3/4” #12 MIOOE# F6HZ-19C836A; F7HH-19E647AB; 4C4H-19C808AA

7488Accumulator Dia. - 3-1/2”Lgth. - 9”In - Male SLOut - FIORFord F-SeriesOE# F7UZ-19C836BB

7489Accumulator FordDia. - 3-1/2”Lgth. - 9”In - Female SL 5/8”Out - MIO 5/8”OE# F75Z-19C836BA

7490Accumulator FordDia. - 3-1/2”Lgth. - 9”In - Male SL #12Out - PADOE# XL3Z-19C836AA

# 0154pad o’rings

# 0017Mo’rings

# 0154pad o’ring# 0017M

o’ring

# 0015Mo’ring

# 0015o’ring

# 0017Mo’ring

# 0015o’ring # 0015

o’ring# 0015o’ring# 0017M

o’ring

# 0154pad o’ring

Includes plastic housing and switch.

Page 23: Receiver Driers Accumulators, and In-Line Filters Receiver

RE

CE

IVE

R D

RIE

RS

© 2017 MEI Corporation538

RECEIVER DRIERSNOTE: Drier mfg’s have discontinued using moisture indicators. We will supply moisture indicators where applicable while supply lasts. #6 = 3/8” #8 = 1/2” #10 = 5/8” #12 = 3/4”

OUT

IN

7540Dia. - 3”Lgth. - 10”In/Out 1/2” x 1/2” Male Flare30 cu.in. desiccantIn-Line Filter DrierOE# EK 304

7503Dia. - 2 1/2”Lgth. - 6 3/4”M18 Inlet / #0076 o’rigM20 Outlet / #0077 o’ringMale O’ring, In-line DesignGMC OE# 15982368

7502Dia. - 2 1/2”Lgth. - 10”In/Out - 3/8” x 3/8” Male O’ringRed Dot remote condenser

1/2”-20course threadcheck valve

IN OUT

# 0011o’rings

# 0011o’rings

# 0076o’rings

# 0076o’rings

# 0076o’rings

7514Dia. - 2 1/2”Lgth. - 6 5/16”In - M18 MaleOut - Fine Thread(1) M10 PortTop Sight GlassOE# 33-0382A; 088370-0

OUT

fine threadcheck valve

ININ OUT

7517 Dia. - 3 3/4” Lgth. - 10 3/4”In/Out - 1/2” x 1/2” Male Flare41 ci.in. desiccantTYPE AH414 In-LineDrier/TransAir A/C

IN

OUT

7504Dia. - 2 1/2”Lgth. - 7”In/Out - 1/2” x 1/2” Male Flare 16 cu.in. desiccant In-Line DrierOE# WAH 164

7513Dia. - 2 1/2”Lgth. - 6 5/16”In - 3/8” Male O’ring Out - 1/2”-20 Course Thrd(1) M10 PortTop Sight GlassOE# 33-0038A; 085623-00

7515Dia. - 2 1/2”Lgth. - 6 5/16”In - M18 Male Out - M18 Male(1) M10 PortTop Sight GlassOE# 33-0383A; 088371-00

IN OUT

7519Dia. - 2 1/2”Lgth. - 6 5/16”In - M18 Male Out - Fine ThreadM10 Switch PortTop Sight GlassGM Chasis Motor HomeOE# 085686-00

IN

fine threadcheck valve

OUT

7524Dia. - 2 1/2”Lgth. - 6.32” In/Out - M18 Male M10-1.25 Switch PortTop Sight GlassOE# 085722; RV218337

OUT IN

OUTIN

7541Dia. - 2 3/4”Lgth. - 8 1/2”In/Out - 1/2” x 1/2” Male Insert O’ring 16 cu.in. desiccant In-Line Filter Drier w/sight glassCARRIER OE# 14-00288-00; WSG 164 MIO

#0013 o’rings

Page 24: Receiver Driers Accumulators, and In-Line Filters Receiver

RE

CE

IVE

R D

RIE

RS

© 2017 MEI Corporation 539

RECEIVER DRIERSNOTE: Drier mfg’s have discontinued using moisture indicators. We will supply moisture indicators where applicable while supply lasts. #6 = 3/8” #8 = 1/2” #10 = 5/8” #12 = 3/4”

# 0142#12 stat seals

7554Accumulator Dia. - 3 1/2”Lgth. - 10”In/Out - #12 Stat Seals2006-2003 Topkick/Kodiak OE# 1132813

7552Accumulator Ford Dia. - 3 1/2”Lgth. - 11”In - 5/8” FIOROut - 3/4” FIOR2011-2007 E-Series w/diesel engineOE# 7C2Z-19C836AA

7551Dia. - 3”Lgth. - 10 1/2”30 cu.in. desiccantIn-line Filter DrierIn/Out - 5/8” Male FlareCarrier OE# WAH305

OUTIN

7549Dia. - 3”Lgth. - 11 1/2”30 cu.in. desiccant In-line Filter Drier w/sight glass In/Out - 1/2” Male Insert O’ringCarrier OE# ADK304; WSG304MOI

OUTIN

7548Dia. - 3”Lgth. - 10”30 cu.in. desiccantIn-Line Filter Drier w/sight glassIn/Out - 1/2” Male FlareCarrier OE# WSG304

OUTIN

# 0013 o’rings

7547Dia. - 2 1/2”Lgth. - 7”Pad Type DrierCAT OE# 113-3497

# 0011 o’rings

# 0017 o’ring

# 0015 o’ring

7546Dia. - 2 1/2”Lgth. - 10”Pad Type DrierKUBOTA 3F999-10740Komatsu 20Y-979-320CAT OE# 176-1902

# 0135 o’rings

# 0011 o’rings

7545Dia. - 3”Lgth. - 10 1/2”Pad Type Drierwith 16mm portVOLVO OFF-ROAD OE# 11104567

# 0017 o’rings

7544Accumulator, w/desiccantDia. - 3 1/2”Lgth. - 9 3/4”In/Out: #12, 1-1/16”-16 Female Insert O’ring CAT OE# 089320-00; 197-6218

IN OUT

7542Dia. - 2 3/4”Lgth. - 8 1/2” In/Out - 1/2” x 1/2” Male Flare O’ring16 cu.in. desiccantIn-Line Drier w/sight glassOE# WSG164 FO

7543Accumulator, w/o desiccantDia. - 3 1/2”Lgth. - 8 3/4”In/Out: #12, 1-1/16”-16 Female Insert O’ringCAT OE# 101-8789, 700001, 151-5261

# 0017o’rings

use # 0170special o’rings (not supplied)

Page 25: Receiver Driers Accumulators, and In-Line Filters Receiver

RE

CE

IVE

R D

RIE

RS

© 2017 MEI Corporation540

RECEIVER DRIERSNOTE: Drier mfg’s have discontinued using moisture indicators. We will supply moisture indicators where applicable while supply lasts. #6 = 3/8” #8 = 1/2” #10 = 5/8” #12 = 3/4”

7566Dia. - 4”Lgth. - 7”In/Out - #8 Stat SealsFreightliner Coronado A22-63994-001

# 0131#8 stat seals

IN OUT

7556Dia. - 2 1/2”Lgth. - 8 1/4”Pad Style Drier2003-06 Sprinter Van, 2.7TD 051-03570AA

7557Dia. - 1 5/8”Lgth. - 11 5/8”Pad Style Drier2007-08 Sprinter VanOE# 680-013634AA

# 0110o’rings

# 0011o’rings

# 0142#12 stat seals

# 0131#8 stat seals

7559Dia. - 4”Lgth. - 7”In/Out - #8 Stat SealsFreightliner Columbia, M2OE# A22-63992-000; A22-63992-001

7560Dia. - 2 1/2”Lgth. - 7 3/4” (13.88” OAL)MIO fittings with orifice tubeCAT OE# 257-3227

IN

OUT

OUT IN

7562Dia. - 2 5/8”Lgth. - 7 1/2”In - 3/8” #6 Male O’ringOut - 3/8” #6 Female O’ring16 cu.in. desiccantIn-Line Drier w/Pressure Relief VavleKysor OE# 402618

7558Accumulator Dia. - 3 1/2”Lgth. - 10”In: PAD / Out: #12 Seals13mm Charge PortM12-1.5 Switch Port2003-2008 GMC G Series OE# 25760829

7555Dia. - 3”Lgth. - 6 1/2”In/Out - 3/8” x 3/8” Male O’Ring Top Sight Glass, P.R.V. & Moisture Indicator OE# RD5-9419-0

7564Dia. - 3” Lgth. - 14.35” #6 Spring Lock ConnectionsMoisture IndicatorFord New Holland OE# 89154-00

7565Dia. - 4”Lgth. - 6 3/4”In/Out - 3/8” x 3/8” Male O’ringSide Sight Glass Fuse PlugVolvo Off Road VREOE# RD5-6075-0

# 0025 o’rings

7568Pad Type DrierDia. - 2.4”Lgth. - 10” CAT# 176-1902

7567Dia. - 3”Lgth. - 10”In - 3/8” Male O’ringOut - 3/8” Male O’ring Western Star 088586-00

Page 26: Receiver Driers Accumulators, and In-Line Filters Receiver

RE

CE

IVE

R D

RIE

RS

© 2017 MEI Corporation 541

RECEIVER DRIERSNOTE: Drier mfg’s have discontinued using moisture indicators. We will supply moisture indicators where applicable while supply lasts. #6 = 3/8” #8 = 1/2” #10 = 5/8” #12 = 3/4”

7579Dia. - 2-3/4” Lgth. - 8-1/2”In/Out - #6 MIOR12 Switch PortVolvo Construction A25B OE# 11005931

7580Dia. - 3”Lgth. - 8”R134a Port3/8” Male Insert O’ringsVolvo Loader OE# 20490945

R134aPort

# 1418 switch# 0154pad o’rings# 0017Mo’rings

7578Accumulator w/Hose Ford 2008-09OE# 8C3Z-19C836C

OUTIN

7577Dia. - 3”Lgth. - 10” Male x FemaleTop Sight GlassFord/New HollandOE# 803-380, 82012480

7576AccumulatorDia. - 3 1/2”In - FIO 5/8”Out - MIO 5/8”J. Deere, 670D GraderOE# 803-465, AT190809

7574Dia. - 3”Lgth. - 11 1/2”In - #6 Female O’ringOut - #6 Male Insert O’ringJ. Deere OE# AL163559, 088549-00

7575Dia. - 4”Lgth. - 7”In - #6 Female O’ringOut - #6 Male Insert O’ringJ. Deere OE# AL162467

7573Dia. - 3”Lgth. - 11 1/2”In - #6 Female O’ringOut - #6 Male Insert O’ringJ. Deere OE# RE214440, 088545-00

7571Dia. - 2-3/4”Lgth. - 10”12.45mm PortsPad Type DrierMITSUBISHI FUSO

7572Dia. - 4”Lgth. - 7 3/4”In - #6 Female O’ringOut - #6 Male Insert O’ringCASE TRACTOROE# 86984155

12.45mmPort

12.45mmPortfemale port

female port

7570 .......... 3/8” x 3/8” MIO 7570M ........14mm / #0025 o’ringsDia. - 2.6”Lgth. - 11 3/8”(2) Female PortsHINO TRUCK

7569Pad Type Drier(will replace Type 1 Driers)Dia. - 2.9”Lgth. - 9”Linkbelt ExcavatorOE# YT54500003P1

3/8”-24Port

M10 Port # 0025

o’rings

Type 2

Page 27: Receiver Driers Accumulators, and In-Line Filters Receiver

RE

CE

IVE

R D

RIE

RS

© 2017 MEI Corporation542

RECEIVER DRIERSNOTE: Drier mfg’s have discontinued using moisture indicators. We will supply moisture indicators where applicable while supply lasts. #6 = 3/8” #8 = 1/2” #10 = 5/8” #12 = 3/4”

IN

OUT

#6 = 3/8” #8 = 1/2” #10 = 5/8” #12 = 3/4”

7593Dia. - 3”Lgth. - 6-1/4”In/Out - 3/8” x 3/8” Male O’ringFemale Switch PortPressure Relief ValveTop Sight GlassTEREX Wheel Loader SKL863, SKL873

7594Dia. - 3”Lgth. - 6-1/2”In - #6 Male O’ringOut - #6 Male O’ringMale Switch PortCAT Exv., M318 / FNH Excavator EC270 OE# 73186213

7584GMC C/K 10-35 Series (2nd design) Dia. - 3 1/2”Lgth. - 8”(1) Male Pad (1) Female PadR134a Charge PortM12 Switch PortOE# 15827280; 1411812

7585Pad Mount Drier Dia. - 4”Lgth. - 7”Freightliner Cascadia OE# 22-66700-000

# 0131 sealing washers

7586Pad Mount Drier Dia. - 4”Lgth. - 7”Freightliner M2OE# A22-66600-000

# 0131 sealing washers

7587Ford 2008-2010 F250 / 500SD w/gas engineOE# 8C3Z-19C836B

7592Pad Mount Drier Dia. - 2-3/8”Lgth. - 7-1/2”VOLVO Excavators, EC SeriesOE# 14509377

7588Accumulator Dia. - 7-1/2”Lgth. - 13-1/4”In: PAD Out: #12 Female SL13mm Charge PortFord Transit-connectOE# 9T1Z-19C836A; YF3625

7595Accumulator w/o desiccant Dia. - 3-1/2”Lgth. - 9-3/4”In/Out - #12 Female O’ring (1/16” -16 thread)CAT Construction Equip.OE# 186-6189

# 0015 (#10 o-ring)

# 0017Mo-ring

# 0154pad o-rings

13mmcharge port

7583AccumulatorDia. - 3 1/2”Lgth. - 11”In - FIOR #10Out - PADFord E-Series OE# 7C2Z-19C836B

7596Dia. - 3”Lgth. - 10-1/2”In - #6 Male O’ringOut - #6 Female O’ringSwitch Port, 7/16” Male FlareSide Sight GlassTop Mount BracketFNH Backhole 555E-675EOE# 85804063

7597Dia. - 4”Lgth. - 8-1/2”In - 3/8” Female O’ringOut - 3/8” Male O’ringCombines, Forage Harvesters, TelehandlersOE# AZ45582

Page 28: Receiver Driers Accumulators, and In-Line Filters Receiver

RE

CE

IVE

R D

RIE

RS

© 2017 MEI Corporation 543

RECEIVER DRIERSNOTE: Drier mfg’s have discontinued using moisture indicators. We will supply moisture indicators where applicable while supply lasts. #6 = 3/8” #8 = 1/2” #10 = 5/8” #12 = 3/4”

7600Dia. - 2 1/2”Lgth. - 8”In - 3/8” Male O’ringOut - 3/8” Female O’ringTop Sight GlassMoisture Indicator(2) 3/8”-24 Female Switch PortsUniversal Flex Type

7600BDia. - 3”Lgth. - 10”In - 3/8” #6 Male O’ringOut - 3/8” #6 Female O’ringMoisture Indicator(2) 3/8”-24 Female Switch PortsUniversal Flex Type

#6 = 3/8” #8 = 1/2” #10 = 5/8” #12 = 3/4”

7606Drier ISUZU OE# 8-97175-137-0

7607Drier/pad type ISUZU OE# 8-97118-190-1

OUT

OUT

OUTIN

IN

IN

7605Drier ISUZU OE# 8-97183-124-0

7604Drier ISUZU OE# 1-83535-068-0

7603Drier ISUZU OE# 8-97308-332-0

7602Drier/pad typeISUZU OE# 8-97366-991-0

7599Pad Mount Drier w/Trinary SwitchDia. - 2-1/2”Lgth. - 9” GMC/ISUZU OE# 8-98039-052-0

7601Drier/elementISUZU OE# 1-83535-097-0

7598Drier CartridgeFord F250-550SD, 6.7L Diesel OE# BC3Z-19C836A

OUTIN

use #8999 Fitting Kit

use #8999 Fitting Kit

7600ADia. - 3”Lgth. - 8”In - 3/8” #6 Male O’ringOut - 3/8” #6 Female O’ringMoisture IndicatorPressure Relief Valve(3) 3/8”-24 Female Switch PortsUniversal Flex Type

use #8999 Fitting Kit

IN

OUT

Page 29: Receiver Driers Accumulators, and In-Line Filters Receiver

RE

CE

IVE

R D

RIE

RS

© 2017 MEI Corporation544

RECEIVER DRIERSNOTE: Drier mfg’s have discontinued using moisture indicators. We will supply moisture indicators where applicable while supply lasts. #6 = 3/8” #8 = 1/2” #10 = 5/8” #12 = 3/4”

7609Drier w/switchISUZU OE# 1-83535-080-0

7614Drier (steel)Dia. - 2-1/2”Lgth. - 8”In/Out - MIO, M18 metricTop Sight GlassSide SwitchDoosan Excavator DX255LC OE# 2204-6039A

7615Drier (aluminum)Dia. - 2.38”Lgth. - 9-1/2”In/Out - PADFarm & Offroad, Kubota Tractor OE# T2055-72230

7613DrierDia. - 2-7/8”Lgth. - 7-1/2”In/Out: 3/8” #6 MIOPort: 7/16”-20 threadJ.Deere / Liebherr / Terex5821662227

7611Drier ElementFord F250-550SD6.2V8 Gas, 6.7L Diesel OE# BC3Z-19C836B

7612Dia. - 3”Lgth. - 10-1/2”In/Out - #6 x #6 MIO(1)1/4” Male Port(2) 1/4” Female PortsSide Sight GlassVolvo Offroad OE# 1089855

#6 = 3/8” #8 = 1/2” #10 = 5/8” #12 = 3/4”

7608Drier/pad type ISUZU OE# 1-83535-095-0

7616 Drier (steel) Dia. - 2-1/2”Lgth. - 10-3/4”In/Out - PAD In-Line Drier (steel)Farm & OffroadCAT OE# 320-0562; 320-0563

7618 Drier (steel)Dia. - 2.36”Lgth. - 8.98”In/Out - PAD 3/8”-24 Female Port w/Binary Sw.Farm & OffroadHyundai Construction OE# 11N6-90060

7619 Drier (steel)Dia. - 2.5”Lgth. - 6”In/Out - PAD 3/8”-24 Switch PortFarm & OffroadJohn Deere OE# AL204865

7620 Drier (aluminum)Dia. - 2.36”Lgth. - 9”In/Out - PAD Top Sight Glass(2) Switch PortsFarm & Offroad, John Deere

7617 Dia. - 2”Lgth. - 11-3/4”Farm & OffroadManitou MLA628OE# 564207

IN OUT

7/16”-20

3/8” #6 MIO

use #0165Sealing Washers

Page 30: Receiver Driers Accumulators, and In-Line Filters Receiver

RE

CE

IVE

R D

RIE

RS

© 2017 MEI Corporation 545

RECEIVER DRIERSNOTE: Drier mfg’s have discontinued using moisture indicators. We will supply moisture indicators where applicable while supply lasts. #6 = 3/8” #8 = 1/2” #10 = 5/8” #12 = 3/4”#6 = 3/8” #8 = 1/2” #10 = 5/8” #12 = 3/4”

7621 Drier (aluminum)Dia. - 2.36”Lgth. - 7.38”In/Out - PAD Farm & OffroadJohn Deere OE# RE380910

7622 Drier Dia. - 1-3/4”Lgth. - 20-1/2” In/Out - #6 x #6 Male FlareFarm & Offroad, fits 12F/13K Motor GraderCAT OE# 1P6541

7623 In-Line Drier Dia. - 2-1/2”Lgth. - 11” In: #6 Male O-ring Out: #8 Male O-ringFarm & Offroad, fits 24M Motor GraderCAT OE# 283-4237

7624 Dia. - 4”Lgth. - 8-1/2In/Out - 3/4” #12 Male O’ring fits Carrier 68AC430 Rooftop UnitsCarrier AC OE# 65-62004-00

IN

IN

IN

IN

OUT

OUT

OUT

OUT

7629Drier (steel)Dia. - 3”Lgth. - 7” Side Pad Type Fittings CAT OE# 355-1793

7628Accumulator (steel) Dia. - 4”Lgth. - 8-1/2” Top Pad Type Fittings CAT OE# 3200564

7627Accumulator (steel)Dia. - 4”Lgth. - 9-5/8” Front Pad Type Fittings CAT OE# 308-2583

7630Drier (steel)Dia. - 4”Lgth. - 9-1/2” In: #12 MIO Out: #12 FIOR CAT OE# 374-5909

7632Drier (steel)Dia. - 3-1/2”Lgth. - 7-1/2” In/Out - #6 x #6 MIO Side Sight Glass 7/16” Male Switch PortBottom Mounting BracketFarm & Offroad

7631Drier (aluminum)Dia. - 2-3/4”Lgth. - 8-1/2” In/Out - #6 x #6 MIOCAT OE# 164-0622

7625Drier (aluminum)Dia. - 2-1/2”Lgth. - 9”In/Out: Pad FittingsLow Pressure SwitchCAT OE# 125-1642

7626Drier (aluminum)Dia. - 2-3/8”Lgth. - 10-1/4” In/Out: Pad FittingsCAT OE# 327-6558

Page 31: Receiver Driers Accumulators, and In-Line Filters Receiver

RE

CE

IVE

R D

RIE

RS

© 2017 MEI Corporation546

RECEIVER DRIERSNOTE: Drier mfg’s have discontinued using moisture indicators. We will supply moisture indicators where applicable while supply lasts. #6 = 3/8” #8 = 1/2” #10 = 5/8” #12 = 3/4”

8999Universal Drier Fitting Kit

7600 Dia. - 2 1/2”Lgth. - 8”In - 3/8” Male O’ringOut - 3/8” Female O’ringTop Sight GlassMoisture Indicator(2) 3/8”-24 Female Switch Ports

P/N Qty. Description• 0011 ......... 10 ......... 3/8” O’rings• 4136 .......... 1 ......... 3/8” MOR to 3/8” MIO drier adapter• 4137 .......... 1 ......... 11/16” MOR to 3/8” MIO drier adapter• 4161 .......... 1 ......... 3/8”-24 male to M10 sw. port adapter• 4162 .......... 1 .......... 3/8”-24 male to 12mm metric adapter• 4165 .......... 1 .......... 3/8”-24 to 13mm charge port adapter• 4166 .......... 1 .......... 3/8”-24 to 16mm charge port adapter• 4167 .......... 1 .......... 7/16” FF to M10 Male sw. port adapter• 4168 .......... 1 .......... M10 FF to 7/16” MF, R12 flare adapter• 4913 .......... 2 ......... 3/8” MOR to Flare adapter• 4922 .......... 2 ......... 3/8” MOR to 3/8” FF adapter• 5527A ...... 1 ......... 3/8” MOR, 3/8” FOR, R12 Inline Chg Ftg.• 5685 .......... 1 ......... 3/8”-24, Pressure Relief Valve• 8900 .......... 2 ......... 3/8”-24 male thrd. to 7/16” MF, R12 adpt.• 8915 .......... 5 .......... Std. Valve Cores R12/R134a

Universal Drier and Fitting KIT - great for service trucksAllows the use of Standard or Metric Charge Port Fittings

Has Multiple Charge Ports for use with #8999 Fitting Kit

#6 = 3/8” #8 = 1/2” #10 = 5/8” #12 = 3/4”

7634Drier (aluminum)Dia. - 2-3/8”Lgth. - 10-1/4” In/Out - PADFarm & Offroad Komatsu OE# 51440-A1180

7635Pad Drier (steel)In/Out - PADMoisture IndicatorMack / Volvo OE# 82771584

7633In-line Filter Drier (steel)Dia. - 2-3/4”Lgth. - 9-1/2” In/Out - #8 x #8 MIO41 cu.in. desiccantBus ApplicationsTransAir OE# 212028

IN

OUT

OUTIN

7636Accumulator, Desiccant Bag KitFord Transit Van OE# BK2Z-19C836A

7637Drier, Desiccant Bag KitR134aFord / Sterling Trucks

# 0174 o’rings

for 3” diameter driers see #7600A and 7600B (page 543).