REFERENCE DU DOCUMENT / DOCUMENT REFERENCE Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 1/70 CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION. HYPER X INTERFACE MANUAL FOR HYPERX READERS LPR, LMB, LML Rédigé par / Written by : W. Lobert Date : 8 Aug 2003 Signature : Approuvé par / Approved by : X. Leblan Date : Signature : Autorisé par / Authorized by : P. Gobrecht Date : Signature :

Reader Interface Manual

Embed Size (px)

Citation preview

Page 1: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 1/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

HYPER X

INTERFACE MANUAL FOR HYPERX READERS

LPR, LMB, LML

Rédigé par / Written by : W. Lobert

Date : 8 Aug 2003

Signature :

Approuvé par / Approved by : X. Leblan

Date :

Signature :

Autorisé par / Authorized by : P. Gobrecht

Date :

Signature :

Page 2: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 2/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

EVOLUTIONS SUCCESSIVES /SUCCESSIVE CHANGES INDICE /

REVISION INDEX

DATE MODIFIE PAR / CHANGED BY

OBJET / DESCRIPTION

A 18 Sept 2002 W. Löbert Creation

B 08 Aug 2003 W. Löbert Addition §2.4 ,additions in §5, addition §8.4.23

C 01 Sept 2003 W. Löbert Addition §1.3

Page 3: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 3/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

TABLE OF CONTENTS 1. GENERAL INFORMATION .................................................................................................................................... 5

1.1 DESCRIPTION OF THE HYPERX READERS............................................................................................................ 5 1.2 BASIC OPERATION ................................................................................................................................................ 5 1.3 POWER SUPPLY .................................................................................................................................................... 7 1.4 READER FIRMWARE VERSION............................................................................................................................... 7

2 OVERVIEW................................................................................................................................................................ 8 2.1 CONNECTORS ....................................................................................................................................................... 8 2.2 FRONT PANEL....................................................................................................................................................... 8 2.3 ANTENNA INDICATOR LIGHT.............................................................................................................................. 10 2.4 READER HARDWARE CHECK AFTER POWER-UP/RESET ........................................................................................ 11 2.5 AUTODIAGNOSTIC .............................................................................................................................................. 12

3 CONFIGURING THE MODULAR READER ...................................................................................................... 13 3.1 ISO2 AND WIEGAND INTERFACES .................................................................................................................. 14 3.2 ASYNCHRONOUS SERIAL LINK............................................................................................................................ 15 3.3 MESSAGE MODE ................................................................................................................................................. 16 3.4 RELAY OPERATION ............................................................................................................................................. 17 3.5 BUZZER OPERATION ........................................................................................................................................... 18 3.6 CODE FILTERING WITH THE DISTRIBUTOR CODE................................................................................................. 18 3.7 SWITCHING MODE FOR DOUBLE READER............................................................................................................ 18 3.8 HOST INTERFACE ............................................................................................................................................... 18

4 CONFIGURING THE COMPACT READER (LPR) ........................................................................................... 19 4.1 ISO2 AND WIEGAND INTERFACES .................................................................................................................. 19 4.2 ASYNCHRONOUS SERIAL LINK............................................................................................................................ 20 4.3 MESSAGE MODE ................................................................................................................................................. 22 4.4 RELAY OPERATION ............................................................................................................................................. 22 4.5 BUZZER OPERATION ........................................................................................................................................... 23 4.6 CODE FILTERING WITH THE DISTRIBUTOR CODE................................................................................................. 23 4.7 HOST INTERFACE ............................................................................................................................................... 23 4.8 READING RANGE................................................................................................................................................ 23 4.9 OPERATING CHANNEL ........................................................................................................................................ 24

5 CONFIGURING THE ENHANCED COMPACT READER (LMB) .................................................................. 25 5.1 USING THE DISPLAY/BUTTONS............................................................................................................................ 25 5.2 PARAMETER SETTINGS ....................................................................................................................................... 26 5.3 PARAMETER DESCRIPTION.................................................................................................................................. 27

6 OPEN-COLLECTOR INTERFACES .................................................................................................................... 32 6.1 MAGNETIC STRIPE CARD INTERFACE «ISO2».................................................................................................... 32 6.2 WIEGAND COMPATIBLE INTERFACE.................................................................................................................... 34

7 ASYNCHRONOUS INTERFACE .......................................................................................................................... 36 7.1 INTRODUCTION................................................................................................................................................... 36 7.2 TRANSMISSION CHARACTERISTICS ..................................................................................................................... 37

Page 4: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 4/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

7.3 READER IN POLLED MODE ................................................................................................................................. 37 7.4 READER IN INTERRUPT MODE ............................................................................................................................ 40

8 JBUS/MODBUS READER COMMANDS ............................................................................................................. 42 8.1 COMMANDS FOR ALL READERS .......................................................................................................................... 43 8.2 SPECIAL COMMANDS FOR THE MODULAR READER.............................................................................................. 48 8.3 SPECIAL COMMANDS FOR THE LPR .................................................................................................................... 50 8.4 SPECIAL COMMANDS FOR THE LMB................................................................................................................... 52

9 DIGITAL I/O (LMB ONLY) ................................................................................................................................... 60 9.1 DIGITAL INPUTS ................................................................................................................................................. 60 9.2 DIGITAL OUTPUTS.............................................................................................................................................. 60

10 EXTERNAL CONNECTIONS................................................................................................................................ 62 10.1 CONNECTORS ..................................................................................................................................................... 62 10.2 ASYNCHRONOUS LINK........................................................................................................................................ 63 10.3 OPEN-COLLECTOR INTERFACE............................................................................................................................ 66 10.4 OUTPUTS (JR3 – LMB ONLY) ............................................................................................................................ 68 10.5 INPUTS (JR4 – LMB ONLY) ............................................................................................................................... 68 10.6 RELAY (LPR AND MODULAR) ............................................................................................................................ 68

11 APPENDIX A : ALGORITHM FOR CALCULATING THE CRC16 ................................................................ 69 12 APPENDIX B : CHANNEL FREQUENCIES ....................................................................................................... 70

Page 5: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 5/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

1. GENERAL INFORMATION

1.1 Description of the HYPERX readers HYPERX™ is a multi-tag dynamic identification system using microwaves. A ‘reader’ emits microwaves up to a distance of one or more meters, depending on model. When a tag enters this zone, it modulates this radiation, thereby sending its code back to the reader, which then processes the received signal and extracts the code. There are two types of readers, modular (different modules assembled in a rack) and compact. For the modular readers, SPI is the reader module which provides the host interface. SPI performs digital processing of the signal received from the microwave receiver module (SAM or LAM) and communication functions with a host. It plugs into a custom rack for single-Europe size boards, taking up a slot of width 6E. A custom backplane provides interconnection between the modules. The compact readers are compact versions of the basic modular reader in the form of a single box. There are two types of compact readers, the Basic Compact Reader (LPR) and the Enhanced Compact Reader (LMB). They perform basically the same functions as the modular reader, with differences in performance (see the appropriate product specifications).

Basic functions performed are :

• tag detection

• communication interfaces: - asynchronous serial link (RS 232, RS 422 or RS 485) using JBUS™ / MODBUS™ protocol

(polled or interrupt) - compatible magnetic stripe card format "ISO-7811/2"

- compatible WIEGAND tags

• relay 24V/1A for external circuit-switching (modular and LPR)

• on-board log (time-stamped) in non-volatile memory (LMB only) Certain functions described in this document are only relevant to recent firmware versions. Identify the version you are equipped with and make sure the desired function is supported.

1.2 Basic operation

1.2.1 All readers Tags are encoded with a HYPERXTM programming device. They can contain a user code of up to 27 characters (digits, uppercase letters and some punctuation symbols). They also contain a 3-character distributor code.

When a tag is first detected by the reader, it is stored in an internal buffer and remains present for a time Tr. After this time, the tag is removed from memory. At first detection, a message for the host interface is generated. In most cases (ISO2, Wiegand, asynch link interrupt mode) this message is immediately sent, in one case (asynch link polling mode) the message is only sent on request by the host. If a tag is detected by the reader and it is still in memory (two detections of same tag within the time Tr), a new message is not normally generated (exception is message mode 2, see chapter 3.3). The timer associated with this tag is then reset so that the tag remains present for a further time Tr. Thus, for a tag which is presented to the reader and remains there, only one message is generated after

Page 6: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 6/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

the initial detection. The tag must be removed for a time greater than Tr in order for a second message to be generated. The default value for Tr is 1 second. The time Tr is hereafter referred to as the tag persistence time.

After power-up or a processor reset, the readers first go through an auto-test phase and perform a number of hardware checks. If a hardware fault is detected, the reader will automatically reset after a period of a few seconds. During this period, it is possible for the user to determine the nature of the fault (if the processor is still capable of executing the firmware program). If the reader is in interrupt mode, a message will automatically be sent to the host, if in polling mode, the "get init errors" MODBUS command can be sent (see §8.1.7). The antenna lamp, if present, remains red fixed, to indicate the fault.

1.2.2 Modular reader Once a second, reader status information is internally collected. This information is available to a host connected by a serial JBUS link. It also affects the flashing rate of the CPU led on the front panel (for SPI module) and the colour and flashing rate of the antenna indicator lamp (see chapter 2.3).

Reader settings are made through on-board DIP switches (2 rows of 8).

An SPI module can accommodate up to two receivers, each with its own antenna. In this case, all modules making up the two receivers are present in the same wide bay. This is known as a Double Reader. When a tag is detected, status information in the message to the host indicates at which antenna the tag was detected. This information is only available if an asynchronous serial link connects the reader to the host.

For the Double Reader, in some cases signal feed-through on the antenna cables can cause a tag detected by one antenna to be “seen” by both receivers. This produces two detection messages, one corresponding to each antenna. In order to counter this effect, if it occurs, a special switching mode of operation can be used whereby only one of the two receivers is active at a time, switching taking place every 150ms. This means however that during the 150ms, one of the antennas will not detect tags that may be present and this may reduce its reading efficiency, especially for high-speed or multi-tag applications.

If during the auto-test phase, a hardware fault is detected, the CPU green led blinks rapidly. If a fault is found with one of the other modules (SHF or SAM/LAM) then the CPU green led blinks rapidly and the antenna lamp blinks green irregularly. In the case of a hardware fault, an error code is available to the host with the structure given in Table 8-3.

1.2.3 LMB Reader settings are made and displayed using the two 7-segment displays and the two buttons. This allows a much greater flexibility, there is virtually no limit to the number of new parameters that can be added nor to the number of values for any parameter. Settings are stored in non-volatile EEPROM.

This reader has two digital inputs for controlling reading conditions and two digital outputs that can drive relays or other loads.

The other major innovation for this new reader is the on-board logging capability. Up to 4000 time-stamped events can be recorded in non-volatile memory and this can be downloaded when the reader is off-line.

Page 7: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 7/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

1.3 Power Supply Input Voltage LML : 12Vdc nominal, 11,5V min to 15V max. LPR : 12Vdc nominal, 10V min to 15V max. LMB : 12Vdc to 24Vdc nominal, 11,5V min to 28V max. A red led "low voltage", near the power supply connector, indicates the voltage supply is less than 11Vdc.

At the time of the “low voltage” detection, power to the rest of the reader is cut and a timer of about twenty seconds is enabled. After this time, the reader tries to power on. If the voltage is right, the reader will turn on, if the voltage is still too low, it enables the timer again and so on.

Consumption

The LPR consumption is roughly 500 mA at 12 VDC.

The consumption for modular readers depends on their composition. It is typically (for FSM, SHF, SAM, SPI) 1.5 A at 12 VDC

The LMB consumption is roughly 1 A at 12 VDC.

WARNING : For the modular reader, live insertion or withdrawal of the modules can cause irreversible damage !

1.4 Reader firmware Version Modular and LPR : This manual applies to firmware versions up to and including 4.13.

LMB : This manual applies to firmware versions up to and including 1.13

Page 8: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 8/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

2 OVERVIEW

2.1 Connectors There are several PHOENIX - type connectors:

• The 5-pin connectors (5.08mm pitch) are for the serial link to a host. • The 3-pin connector (5.08mm pitch) allows switching (using the internal relay) of an external

circuit (LML and LPR) • The small 4-pin connector (3.81mm pitch) is for control inputs (LMB only) • The small 6-pin connector(3.81mm pitch) is for control outputs (LMB only) • The 2-pin connector(5.08mm pitch) is for the DC power supply (except when modular reader uses

mains power) (See §10.1 for the wiring instructions)

For the modular reader, the connectors are accessible on the front panel of the SPI module. For the compact readers, the connectors are accessible from the back at the top.

2.2 Front Panel

2.2.1 Modular reader

RESET

CPU

RX

TX

SPI

BURST

1

2

4

5

3

Figure 2-1: Front Panel of module SPI, comprising 2 Connectors, 4 leds and 1 Reset button

Page 9: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 9/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

2.2.1.1 Indicator lamps for maintenance Four leds indicate the state of the module and tag activity.

Processor LED (CPU) This green LED can have one of two flashing rates : • slow, roughly 0.5s on 0.5s off, indicating all modules are working normally. • fast, roughly 0.05s on 0.05s off, indicating a problem with one of the modules in the rack. Any other behaviour indicates faulty processor operation. NB : If the reset button is held down, this LED should be on.

Tag activity (BURST) This red LED flashes (50ms) to indicate that a tag has been detected by the reader.

Sending message (TX) This red LED indicates electrical activity on the front panel connector line 01 (TX for the RS-xxx link). It is permanently on in the case of the interfaces ISO2 and WIEGAND.

Receiving message (RX) This red LED indicates electrical activity on the front panel connector line 04 (RX for the RS-xxx link). It is permanently off in the case of the interfaces ISO2 and WIEGAND

2.2.1.2 Reset Button Pushing this button applies a hardware reset to the processor. NB : While the button is held in, the processor is in a reset state and the CPU and BURST LEDs are on. Once released, the processor restarts.

2.2.2 LPR

Figure 2-2 : Front panel of Compact reader

A single red/green lamp (antenna indicator light) is situated in the top-centre of the panel (see §2.3 below).

BALOGH

Page 10: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 10/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

2.2.3 LMB Same outward appearance as the LPR

2.3 Antenna Indicator Light The LED on the antenna (or in the case of the compact readers, on the front panel) indicates the state of the reader. It is under reader software control. It can also be controlled by the host using the JBUS protocol on an asynchronous serial link. The state diagram below shows the different possible states during power-up (or after a processor reset).

State Diagram :

0 2 3

1

a

c

d

b

To

4

e f

5

g h

Events :

a. internal hardware fault detected b. autotest OK c. module fault detected d. module fault disappears e. internal hardware fault detected f. internal hardware fault disappears g. received command “turn reader off” h. received command “turn reader on”

State Name Antenna LED Emission CPU LED6 status

cf dm 0 Test red, fixed off on nd² nd 1 Hardware fault see note 1 off fast blink 0 nd 2 Normal green, regular blink on slow blink 1 1 3 Module fault green, irregular blink on fast blink 1 0 4 Reader not ready red, slow blink off fast blink 0 x³ 54 Reader OFF off off slow blink x x 65 Tag detected off for 1s on x 1 x 75 Tag with low

battery detected short red blink on x x x

Table 2-1:State table for antenna led

Notes :

Page 11: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 11/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

1. The LED behaviour and the timeout duration depend on the nature of the fault. In the case of a faulty configuration, the reset is immediate and the LED stays red. For a hardware fault, reset takes place after 4 seconds.

2. nd = not defined 3. x = don’t care 4. This state only exists for the modular readers. 5. This state is not shown in order not too overload the diagram. It lasts for 1 second, then normal operation resumes. 6. For modular reader only

2.4 Reader hardware check after power-up/reset

After a reset/power-up, the reader goes through an auto-test phase performing a hardware check. During this time which lasts for one or more seconds, the antenna light is red/fixed, the buzzer sounds and the reader is not operational. At the end of the test, an error-status-byte is available. If one or more critical hardware elements failed then the reader is put into the error state (antenna light red/fixed or slow blink, no tag reading) and a reset is automatically generated after a few seconds. If the reader serial link is in interrupt mode, then this error-status-byte is sent over the link. If in polling mode, it can be read with the JBUS command read init errors.

In the case of the enhanced compact reader, the display allows visualizing (with a 2-letter code) the test in progress and the result. At the end of this phase, if there have been no errors, the display is turned off, otherwise an error code is displayed. Note that some of the tests are very fast, so the corresponding display code will not normally be seen. The tests performed are in order :

N° Display Test bit(s) of error code 1 "P" On-chip Ram 2 2 "P0" Off-chip Ram (Log page 0) 2 3 "P1" Off-chip Ram (Log page 1) 2 4 "PE" Code checksum 1 5 "EE" EEPROM 3 6 "SC" SCC 4,5 7 "sn" Electronic serial number 7 8 "rt" Real-time clock 8 9 "IS" Serial interface 6

Error code (1 byte) :

8 7 6 5 4 3 2 1

Bit Description Consequence 1 Code checksum Critical 2 Off-chip Ram Critical 3 EEPROM Critical 4 Bus access SCC Critical 5 SCC Critical 6 Serial interface Degraded 7 Electronic serial number Critical 8 Real-time clock Degraded

A failure of the serial interface is not critical if the host interface uses DATA/CLOCK or WIEGAND. A failure of the RTC is not critical if the log function is not used.

Page 12: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 12/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

Examples of error codes :

Display Meaning 04 EEPROM failure 18 SCC failure 40 Electronic serial number

If the reader serial link is in interrupt mode, then at the end of the test phase, several diagnostic messages are emitted. A first message emits the firmware version, the time and the date:

01.T.000v1.1.4 15:03:36 06/08/03

A second message emits the setup (28 parameters) and the log status :

01.S.000C=0.09.2.1.00.0.0.0.1.3.0.0.01.3.0.0.0.0.0.2.0.0.0.0.0.0.0.2 J=0504

A third message is emitted if a failure occured during the test phase :

01.E.000TEST READER=F(18)

2.5 Autodiagnostic

If the reader is equipped with an antenna that includes an autodiagnositc function (e.g. the model 7023-ASVA), then a further diagnostic test is performed. This test can also be performed at any time using the appropriate JBUS command (see §8.4.23). Once again, if the reader serial link is in interrupt mode then the result of this diagnostic test is emitted :

01.E.000TEST READER=OK : all OK

01.E.000TEST READER=(00) : reader diagnostic error, no hardware errors

01.E.000TEST READER=(18) : hardware failure (SCC)

Page 13: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 13/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

3 CONFIGURING THE MODULAR READER There are two versions of the module currently available, for simplicity hereafter referred to as the old version and the new version. The old version consists of a mother board and a smaller daughter board using traditional through-hole technology. Configuring is done using jumpers. The new version consists of a single board using surface-mount technology. Configuring is done using miniature switches. In order to correctly configure the module, you must identify the version you are installing. In the following paragraphs, text in italics refers to the old version.

For old versions only - some jumpers do not change position : J1 - must be in position 2-3 J6 - must be present J7 - must be absent J13 - must be present in position 2-3 These four jumpers no longer exist on the new version. The different operating modes are selected using switches/jumpers which are either :

• ON (present) or • OFF (absent)

They are identified by their positions on four connectors: • J1 (8 positions 1 to 8) / J3 (10 positions 1 to 10) • J2 (4 positions 9 to 12) / J8 (2 positions 11 to 12) • J4 (8 positions 1 to 8) / J4 (8 positions 1 to 8) • J3 (8 positions 1 to 8) / J5 (8 positions 9 to 16)

Figure 3-1 : Connector locations for SPI module - old board

J5

J4

J8

J3

Page 14: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 14/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

Figure 3-2 : Connector locations for SPI module - new board

The serial link to a host can be one of two types :

• Open-Collector (ISO2 or Wiegand)

• Asynchronous RS 232, RS 422 and RS 485. NB: Only one of these interfaces can be active at a time

Certain switch / jumper combinations are forbidden. If these combinations are detected during the initialisation period (immediately following a reset), an internal reset is generated after a period of 4 seconds. The following combinations are forbidden :

• Message mode 3 together with WIEGAND interface

• Message mode 2 together with POLLING mode

3.1 ISO2 and WIEGAND Interfaces

3.1.1 ISO2 Interface Positions 1 to 4 of J4 must be as follows :

4 3 2 1 message length

OFF OFF OFF OFF variable

OFF OFF ON OFF fixed

3.1.2 WIEGAND Interface Positions 1 to 4 of J4 must be as follows :

4 3 2 1 OFF OFF OFF ON

J3 J4

J2J1

Page 15: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 15/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

3.1.3 Tag persistence Positions 5 and 6 of J4 must be as follows :

6 5 Persistence ON ON 1 s ON OFF 2 s OFF ON 5 s OFF OFF 10 s

3.1.4 Minimum Time Between Messages (MTBM) Positions 7 and 8 of J4 must be as follows :

8 7 MTBM ON ON 1000 ms ON OFF 100 ms OFF ON 200 ms OFF OFF 500 ms

3.1.5 Tag message repetition Position 3 of J3 / 11 of J4 must be as follows :

repetition OFF disabled ON enabled

3.2 Asynchronous serial link

3.2.1 Address The module’s physical address is the logical slave address that the host application software uses to address the module (see §7.3). There are ten usable addresses (1 to 10) as shown below, the settings for 0 and 11 to 15 are used for other functions. The four positions 1 to 4 of J4 determine the physical address:

4 3 2 1 Address ON ON ON ON reserved use ON ON ON OFF 1 ON ON OFF ON 2 ON ON OFF OFF 3 ON OFF ON ON 4 ON OFF ON OFF 5 ON OFF OFF ON 6 ON OFF OFF OFF 7 OFF ON ON ON 8 OFF ON ON OFF 9 OFF ON OFF ON 10 OFF ON OFF OFF Time Designa (see §7.4.2) OFF OFF ON ON Code Only (see §7.4.2) OFF OFF ON OFF ISO2 fixed length (see 3.1.1) OFF OFF OFF ON WIEGAND (see 3.1.2) OFF OFF OFF OFF ISO2 variable length (see 3.1.1)

Page 16: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 16/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

NB : A JBUS command message which has a slave address equal to 0 corresponds to a broadcast message, which explains why a reader cannot have an address of 0 for polling applications.

3.2.2 Character Format and Baud rate Baud rate is chosen using positions 5 and 6 of J4:

6 5 Baud rate ON ON 9600 Bauds ON OFF 4800 Bauds OFF ON 1200 Bauds OFF OFF 19200 Bauds

Format is chosen using positions 7 and 8 of J4: 8 7 Format

ON ON 7 bits data 1 bit even parity ON OFF 7 bits data 1 bit odd parity OFF ON 8 bits data no parity OFF OFF not used

3.2.3 Protocol : polling or interrupt The type of protocol, polled or by interrupt, is chosen with position 5 on J3 / 13 on J5 :

protocol OFF interrupt ON polling

3.2.4 Frame format Position 8 on J3 / 16 on J5 determines the frame format, test (ASCII) or JBUS (binary).

frame format OFF Test - ASCII message ON Normal - JBUS frame

The test format allows connection to a dumb terminal for easy on-site display. For a description see §7.4.2.

3.3 Message mode The mode is chosen using positions 1 and 2 on J3 / 9 and 10 on J5. The mode determines in what cases the detection of a tag causes a message to be transmitted to the host.

Type 0 - Each time a tag is detected, a timer is armed (nominal value = 1s). Tag detection only causes a message to be transmitted if this timer is not active. Each tag detected has a timer associated with it.

Type 1 - This mode is no longer supported

Type 2 - Repeated message transmission while tag is present. Only available for the ISO2 interface and the asynchronous start/stop interface in the interrupt mode.

Type 3 - When a tag “disappears” (is removed from internal memory), an extra message is transmitted to host which includes the tag’s code as well as the number of times that the

Page 17: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 17/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

badge was detected. This number cannot be greater than 99. Not available for the Wiegand interface. Otherwise identical to type 0.

2 (10) 1 (9) message mode OFF OFF Type 3 OFF ON Type 2 ON OFF Type 1 - no longer supported ON ON Type 0

0 1a;1

a;1,2

b

Type 0

0 4

a;2,3

e;4

Type 2

0 1a;1

a;1,2

b; 6

Type 3

Events Actions a : tag is detected 1 : arm disappearance timer b : timeout disappearance 2 : start message transmission e : message is sent 3 : turn off reader 4 : turn on reader 6 : send tag disappearance message

Figure 3-3 : Flow Graphs describing the three message transmission modes

3.4 Relay operation When a tag is detected, the relay operates. The switch / jumper in position 3 on J3 / 11 on J5 determines one of two modes of deactivation (for ISO2 and Wiegand, deactivation is automatic) :

• automatic relay deactivation after 2 second delay.

Page 18: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 18/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

• relay deactivation controlled by host via JBUS

Deactivation OFF automatic ON under host control

3.5 Buzzer operation The switch / jumper in position 4 on J3 / 12 on J5 activates or deactivates the buzzer on tag detection. When enabled, the buzzer emits a short sound (duration 50 ms) each time a tag is read.

Buzzer OFF Enabled ON Disabled

When enabled, the buzzer sounds for 50ms at every tag detection.

3.6 Code filtering with the Distributor code The switch / jumper in position 6 on J3 / 14 on J5 enables or disables this feature. A description is given in chapter 6.2.3. Applies only to ISO2 and Asynchronous interfaces. As of firmware version 4.11, applies to the WIEGAND interface as well.

Filtering OFF Disabled ON Enabled

3.7 Switching mode for Double reader The switch / jumper in position 7 on J3 / 15 on J5 enables or disables this feature. A description is given in chapter 1.2. This feature must be disabled for single readers.

Switch mode OFF Disabled ON Enabled

3.8 Host Interface The following positions on J1 and J2 / J3 and J8 determine the electrical interface to the host, by fixing which lines are physically routed through to the front-panel connector.

Type Position RS-232 1, 11 RS-422 2, 4, 9, 10, 12 RS-485 2, 4, 6, 7,12 ISO2 3, 5, 8

WIEGAND 3, 5, 8 Table 3-1 : LML – Settings for selecting the electrical interface

Page 19: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 19/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

4 CONFIGURING THE COMPACT READER (LPR) The different operating modes are selected using switches which are either : • ON or • OFF They are identified by their positions on four connectors: J1 (12 positions 1 to 12) J2 (8 positions 1 to 8) J3 (8 positions 1 to 8) J4 (8 positions 1 to 8)

Figure 4-1 : Switch locations for configuration of Compact reader

The serial link to a host can be one of two types :

• Open-Collector (ISO2 or Wiegand)

• Asynchronous RS 232, RS 422 and RS 485. NB: Only one of these interfaces can be active at a time

Certain switch combinations are forbidden. If these combinations are detected during the initialisation period (immediately following a reset), an internal reset is generated after a period of 4 seconds. The following combinations are forbidden : • Message mode 3 together with WIEGAND interface • Message mode 2 together with POLLING mode

4.1 ISO2 and WIEGAND Interfaces

4.1.1 ISO2 Interface Positions 1 to 4 of J2 must be as follows :

4 3 2 1 message length OFF OFF OFF OFF variable OFF OFF ON OFF fixed

J2 J1

J4 J3

Page 20: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 20/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

4.1.2 WIEGAND Interface Positions 1 to 4 of J2 must be as follows :

4 3 2 1 OFF OFF OFF ON

4.1.3 Tag persistence Positions 5 and 6 of J2 must be as follows :

6 5 Persistence ON ON 1 s ON OFF 2 s OFF ON 5 s OFF OFF 10 s

4.1.4 Minimum Time Between Messages (MTBM) Positions 7 and 8 of J2 must be as follows :

8 7 MTBM ON ON 1000 ms ON OFF 100 ms OFF ON 200 ms OFF OFF 500 ms

4.1.5 Tag message repetition Position 3 of J3 must be as follows :

repetition OFF disabled ON enabled

4.2 Asynchronous serial link

4.2.1 Address The module’s physical address is the logical slave address that the host application software uses to address the module (see §7.3).

The four positions 1 to 4 of J2 determine the physical address:

Page 21: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 21/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

4 3 2 1 Address ON ON ON ON reserved ON ON ON OFF 1 ON ON OFF ON 2 ON ON OFF OFF 3 ON OFF ON ON 4 ON OFF ON OFF 5 ON OFF OFF ON 6 ON OFF OFF OFF 7 OFF ON ON ON 8 OFF ON ON OFF 9 OFF ON OFF ON 10 OFF ON OFF OFF Time Designa (see §7.4.2) OFF OFF ON ON Code Only (see §7.4.2) OFF OFF ON OFF ISO2 fixed length (see §6.1.2) OFF OFF OFF ON WIEGAND (see §6.2.2) OFF OFF OFF OFF ISO2 variable length (see §6.1.2)

NB : A JBUS command message which has a slave address equal to 0 corresponds to a broadcast message, which explains why a reader cannot have an address of 0 for polling applications.

4.2.2 Character Format and Baud rate Baud rate is chosen using positions 5 and 6 of J2:

6 5 Baud rate ON ON 9600 Bauds ON OFF 4800 Bauds OFF ON 1200 Bauds OFF OFF 19200 Bauds

Format is chosen using positions 7 and 8 of J2: 8 7 Format

ON ON 7 bits data 1 bit even parity ON OFF 7 bits data 1 bit odd parity OFF ON 8 bits data no parity OFF OFF not used

4.2.3 Protocol : polling or interrupt The type of protocol, polled or by interrupt, is chosen with position 5 on J3:

protocol OFF interrupt ON polling

Page 22: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 22/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

4.2.4 Frame format Position 8 on J3 determines the frame format, test (ASCII) or JBUS (binary).

frame format OFF Test - ASCII message ON Normal - JBUS frame

The test format allows connection to a dumb terminal for easy on-site display. For a description see chapter 7.4.2.

4.3 Message mode The mode is chosen using positions 1 and 2 on J3. The mode determines in what cases the detection of a tag causes a message to be transmitted to the host.

Type 0 - Each time a tag is detected, a timer is armed (nominal value = 1s). Tag detection only causes a message to be transmitted if this timer is not active. Each tag detected has a timer associated with it.

Type 1 - This mode is no longer supported

Type 2 - At each tag detection, a message is transmitted to host. During message transmission, microwave emission is switched off. Only available for the ISO2 interface and the asynchronous start/stop interface in the interrupt mode.

Type 3 - When a tag “disappears” (is removed from internal memory), an extra message is transmitted to host which includes the tag’s code as well as the number of times that the badge was detected. This number cannot be greater than 99. Not available for the Wiegand interface. Otherwise identical to type 0.

2 1 message mode

OFF OFF Type 3 OFF ON Type 2 ON OFF Type 1 - no longer supported ON ON Type 0

For a graphical representation of how the modes work, see Figure 3-3.

4.4 Relay operation When a tag is detected, the relay operates. The switch in position 3 on J3 determines one of two modes of deactivation (for ISO2 and Wiegand, deactivation is automatic) :

• automatic relay deactivation after 2 second delay.

• relay deactivation controlled by host via JBUS Deactivation

OFF automatic ON under host control

Page 23: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 23/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

4.5 Buzzer operation The jumper in position 4 on J3 activates or deactivates the buzzer on tag detection. When enabled, the buzzer emits a short sound (duration 50 ms) each time a tag is read.

Buzzer OFF Enabled ON Disabled

4.6 Code filtering with the Distributor code The switch in position 6 on J3 enables or disables this feature. A description is given in chapter 6.2.3. Applies only to ISO2 and Asynchronous interfaces. As of firmware version 4.11, applies to the WIEGAND interface as well.

Filtering OFF Disabled ON Enabled

4.7 Host Interface The following positions on J1 and J2 determine the communications interface to the host, by fixing which lines are physically routed through to the connector.

Type Position RS-232 1, 11 RS-422 2, 4, 9, 10, 12 RS-485 2, 4, 6, 7,12 ISO2 3, 5, 8

WIEGAND 3, 5, 8

4.8 Reading Range The reading range can be coarsely adjusted using switches 6 and 7 on J4. Three ranges are possible :

7 6 range OFF OFF short ON OFF short OFF ON medium ON ON long (normal)

Page 24: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 24/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

4.9 Operating channel The compact reader can operate using 29 different channels. Each channel corresponds to a separate microwave frequency band. This is useful when several readers must be positioned close together. Using different channels on each reader eliminates mutual interference. Positions 1 to 5 of J4 are used. The OFF position for switches are indicated by a blank in order to make the table more readable.

5 4 3 2 1 Channel

ON ON ON ON 1 ON ON ON ON 2 ON ON ON 3 ON ON ON ON 4 ON ON ON 5 ON ON ON 6 ON ON 7 ON ON ON ON 8 ON ON ON 9 ON ON ON 10 ON ON 11 ON ON ON 12 ON ON 13 ON ON 14 ON 15

ON ON ON ON 16 ON ON ON 17 ON ON ON 18 ON ON 19 ON ON ON 20 ON ON 21 ON ON 22 ON 23 ON ON ON 24 ON ON 25 ON ON 26 ON 27 ON ON 28 ON 29

Table 4-1 : Microwave Channel selection

Page 25: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 25/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

5 CONFIGURING THE ENHANCED COMPACT READER (LMB)

5.1 Using the display/buttons

Figure 5-1 : Display/button layout

User interaction with reader settings is done with two 7-segment displays and two buttons.

To display a parameter’s current value, press the Select (red) button repeatedly (or hold it down for more than one second) until the desired parameter title appears then press the Display (black) button.

To change a parameter value, press the Select (red) button repeatedly (or hold it down for more than one second) until the desired parameter title appears then press the Display (black) button repeatedly (or hold it down for more than one second). The decimal point is displayed indicating that a value is about to be changed. When the desired value appears, press the Save (red) button. The display shows “SA” for one second indicating that the new value has been stored.

If you cycle through the values with the black button (the decimal point is on) and change your mind and do not want to change the current value, or if you simply want to visualise the different values, just wait a few seconds, the display will turn off automatically. Alternatively, you can press the reset button.

The display cycles through all the parameters, when it comes to the end it starts again at the beginning. When the display turns off, it remembers its position, so that next time the red button is pressed, display starts with the previously displayed parameter.

In summary: display state action result off press red button display title of current parameter press black button no change title parameter N press red button display title of next parameter press black button display value of current parameter value parameter N press red button display title of next parameter press black button display next value of current parameter + "." value + "." press red button display "SA", store new value press black button display next value of current parameter + "." The display is the right way up when the reader is mounted connectors and lamp towards the bottom. If the reader is mounted with the lamp at the top then the first parameter can be changed so that the display is not upside down. The buttons however do not change functions.

The last parameter displayed (tL - type of reader) is read-only and cannot be changed by the user.

Select/Save

Display/Change

Page 26: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 26/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

It is possible at any time to revert to the default factory settings by pressing the reset button while holding down the Display (black) button.

5.2 Parameter settings All parameters are stored in non-volatile EEPROM memory. The second column indicates the order in which they are displayed.

Parameter Title displayed Value Value displayed Default Notes Display direction 1 -- 0 uP * lamp at bottom

1 dn lamp at top Channel Number 2 nC 1 to 31 1 … 31 9 Tag Persistence 3 tP 0,1s 0

0,5s 1 1s 2 * 2s 3 5s 4 10s 5

Buzzer 4 bu OFF oF on tag detect ON on *

Issuer Code Filtering 5 FI OFF 0 * 1st code 1 EEPROM 2 code in EEPROM

Issuer Code size 6 tC 3 3 * 4 4

Lamp behaviour 7 LE NORMAL 0 * OTHER 1 TBD

Message mode 8 tF 0 0 * 2 2 3 3

Spec Function Tags 9 bF OFF oF * ON on not available yet

Logging 10 Jo OFF 0 time/date-stamped events 1 1 tag detect 2 2 1 plus reset 3 3 * 2 plus errors

RS interface 11 tA RS232 23 * RS422 42 RS485 48

OC interface 12 tO unused nu * Open Collector interface ISO2 fixed IF ISO2 variable Ir WIEGAND IE

Reader Address 13 Ad 1 to 31 1 … 31 1 Baud rate 14 br 9600 96 *

4800 48 1200 12 19200 19

Character Format 15 Fo 8 bit 8n * 7 bit even 7P 7 bit odd 7I

Frame format 16 Fr ASCII AS * ASCII with header for tag code code only CS ASCII without header

Time Designa td special format

Page 27: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 27/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

Parameter Title displayed Value Value displayed Default Notes JBUS Jb

Polling/Interrupt 17 Po Interrupt oF * Polling on

MTBM 18 tb 0,1s 0 Mean Time Between 0,2s 1 * Messages 0,5s 2 (for ISO2/Wiegand) 1s 3 2s 4

Nb Emissions 19 nE 1 to 4 1 … 4 1 emissions in interrupt mode Output1 20 S1 unused 0

Copy buzzer 1 identical to buzzer outpout 2s on read 2 * host 3 under host control

Output2 21 S2 unused 0 SFT vehicle 1 identical to buzzer outpout tag battery low 2 * host 3 under host control

Range 22 Pr 0 to 3 0 … 3 3 3 = max range reserved 23 - Input1 24 E1 disabled oF *

enable reading on Input2 25 E2 disabled oF *

TBD On TBD reserved 26 -

Hopping period 27 Pe 100 ms 0 * As of v1.0.7 150 1 200 2 300 3 400 4 500 5 800 6 1000 7

Reader Type tL undefined Nd display different for old 6012 2 versions, see §5.3.26 6013 3 6034 4 6035 5 7013 6

Table 5-1 : LMB - Parameter settings

5.3 Parameter description

5.3.1 Display direction

Allows reading the display right side up irrespective of the reader installation (lamp at top or lamp at bottom). Choose “uP” for lamp at bottom, “dn” for lamp at top.

5.3.2 Channel number

This is the reader operating frequency, see the table in §12. This only needs to be changed if the installation has several readers or if there are interference problems.

Page 28: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 28/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

5.3.3 Tag persistence

The time a tag remains in internal memory after a single detection. In order for this tag to be able to be read again, it needs to remain undetected for this time. Persistence means that multiple rapid detections of the same tag produce only one message for the host system.

5.3.4 Buzzer

Enable or disable the beep when a tag is detected.

5.3.5 Issuer code filtering

Allows tag filtering based on the distributor code. A value of one corresponds to the traditional auto-learn mode of the other readers, i.e. the distributor code of the first tag detected after a reset becomes the reference code for filtering. A value greater than or equal to 6 indicates filtering according to one or more internally stored codes. These codes in non-volatile memory are loaded with JBUS commands.

Up to six codes can be loaded. For each one there is a bit in the byte as shown in the table below. Bits 2 to 7 represent the six code positions, a one indicates that filtering is active for this code. The value displayed is the decimal value of this byte. Some examples :

Bit 7 Bit 0 filter type display 0 0 0 0 0 0 0 0 No filtering 0 0 0 0 0 0 0 0 1 Auto-learn 1 0 0 0 0 0 1 1 0 filter code 1 6 0 0 0 0 1 0 1 0 filter code 2 10 0 0 0 0 1 1 1 0 filter codes 1 & 2 14 0 0 0 1 1 1 1 0 filter codes 1, 2 & 3 30 0 1 0 0 0 0 1 0 Filter code 5 66

Table 5-2 : Distributor code filtering for LMB

5.3.6 Issuer code length

Cannot be changed (fixed at 3).

5.3.7 Lamp

Defines the behaviour of the lamp. Only one behaviour is available at present :

event Lamp tag detected extinction pendant 1 s tag detected with battery low red flash for 0,3 s normal operation Green blink once a second faulty operation Slow red blink

Page 29: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 29/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

5.3.8 Message mode

Three modes are available : Message mode 0 : tag code message generated for every NEW tag detected Message mode 2 : tag code message generated repeatedly while tag is present Message mode 3 : tag code message generated for every NEW tag detected and for every tag that

disappears (is deleted from internal memory)

5.3.9 Special function tags

Enables the use of the special function tags. These tags allow interacting with the reader at a distance, for example setting up parameters, switching outputs, setting time/date etc. If this parameter is off, the use of all Special Function Tags is disabled. Available as of v1.1.3

5.3.10 Logging

Enables time-stamped logging of events.

value Events logged off None 1 Tags detected 2 Tags + resets 3 Tags + resets + errors

Extracting the log information should be done off-line with special software (using JBUS commands). This can be supplied by BALOGH or developed by the user.

5.3.11 Asynchronous serial interface type

Selects the RS interface type 232, 422 or 485. This interface can be the host interface or the service interface. If it is the host interface, see the comments for the next parameter.

5.3.12 Open Collector interface type

Selects the type of open-collector interface. If the host interface is asynchronous then a value of "nu" (not used) must be stored.

5.3.13 Reader address

The reader address necessary for multi-reader network operation. If the interface to host is point-to-point, leave unchanged.

5.3.14 Baud rate

Selects the asynchronous baud-rate.

5.3.15 Character format

For binary frame format (JBUS) choose 8 bits, for ASCII frame formats select according to host interface.

Page 30: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 30/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

5.3.16 Frame format for tag code

Selects the message format for the tag code message transmitted to the host. For example, for the tag (123)(TAG_CODE) :

In polling mode, select JBUS :

message = 01 03 0e 30 31 32 33 43 4f 44 45 5f 4b 4a 44 47 4e xx xx

In interrupt mode, the choices are :

JBUS, message = 02 04 0e 30 31 32 33 54 41 47 5f 43 4f 44 45 xx xx

ASCII, message = 01.0. 123TAG_CODE (CR)(LF)

Code only, message = 123TAG_CODE

5.3.17 Polling

With polling disabled (interrupt mode), when a tag is detected the message is immediately sent to the host. With polling enabled, this message is only sent as a reply to a JBUS command. If no command is received by the reader during the time the tag is present, the tag disappears i.e. the message is not stored, however if logging is enabled, the tags detection can be verified later.

5.3.18 MTBM

Defines the Mean Time Between Messages for the open-collector interface (due to the fact that some older equipment cannot process back to back message transmission).

5.3.19 Number of emissions For asynchronous interface, in interrupt mode, the maximum number of transmissions of the same tag code if no ACK is received.

For open-collector interface, if the value is greater than one, then the message is repeated. The time between messages is given by the MTBM value.

5.3.20 Output 1

Defines the behaviour of Output 1 :

Value Description 0 Disabled 1 Synchronised to buzzer (50ms at every tag detection) 2 Active for 2 seconds when new tag is detected 3 Under exclusive host control

5.3.21 Output 2

Defines the behaviour of Output 2 :

Page 31: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 31/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

Value Description 0 Disabled 1 Active with Special Function Tag "Vehicle" 2 Active for 2 seconds when tag battery low is detected 3 Under exclusive host control

5.3.22 Range

Selects 4 different values for the range 0 (minimum) to 3 (maximum). This parameter changes the receiver threshold, it does not modify output power.

5.3.23 Input 1

If this parameter is ON, then tag detection is only enabled when the signal on Input 1 is high (Vin > 6V).

5.3.24 Input 2

TBD

5.3.25 Channel Hopping period Determines the time the reader operates in each channel while in the channel-hopping mode.

5.3.26 Reader type

Identifies the reader type.

Reader type display (from v1.0.9) display (up to v1.0.7) 6012 2 12 6013 3 13 6034 4 34 6035 5 35 7023 6 23 6033 7

Page 32: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 32/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

6 OPEN-COLLECTOR INTERFACES

6.1 Magnetic Stripe Card Interface «ISO2»

6.1.1 Description Using this interface allows the reader to take the place of a standard magnetic stripe card reader (ISO 7811-2). This interface consists of three signals, MDATA (negative logic) for the data, STROBE (active low) indicates when data are valid, and PRES_BADGE (active low) a signal encompassing message transmission as shown below. The characters are transmitted synchronously in a frame format at a rate of roughly 1000 bits/s.

1 1 10 0 0NRZ

MDATA

STROBE

T = 1 ms

Figure 6-1: Signal timing for the ISO2 interface. Period for NRZ data is roughly 1 ms

2 ms 50 ms

STROBE or MDATA

PRES_BADGE

Figure 6-2 : Timing showing the signal “Presence Badge”.

The STROBE and MDATA signals are open-collector outputs (circuit shown in Figure 10-9). For proper operation a pull-up resistor of about 1K ohm should be used.

6.1.2 Message format A message consists of a preamble of 15 zeros (for receiver synchronisation), the data frame as described below, and a postamble of 10 zeros. The data are formatted into characters of 5 bits - 4 bits for a binary coding plus one bit for odd parity. The data is framed as shown below.

1 Character 1 Character 1 Character

START data END LRC

Page 33: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 33/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

The checksum (LRC) is the result of an exclusive-or function performed on all the preceding characters. START character = 0BH

END character = 1FH.

In previous firmware versions only digits were allowed as data elements. As of version 4.04 modular and LPR (all versions LMB), extended coding can be used, by which the six letters A to F can be transmitted as data elements. Thus sixteen codes, 0 – 9 and A – F are transmitted using the 16 binary codes available with the 4 bit words. However in this case, the end of the frame can no longer be determined using the END character as it is indistinguishable from the data element ‘F’. The position of the LRC character must be determined relative to the end of the transmission, from the postamble of 10 zeros.

The contents of the data field depend upon the message mode chosen and the length. For a variable length frame, this field begins with a three-character distributor code, if no distributor-code filtering is enabled, followed by the user-code. For the fixed length frame, this field contains exactly 37 characters, the characters after the user-code, if there are less than 37, are all equal to 0DH.

In the case of message mode 3, the data also contains the number of times the tag was detected, a two-character field. The special separation character 0CH precedes this number.

The order of bit transmission for each character is LSB first.

Typical examples of the data field for a user code of length n digits :

message mode 0, length variable distributor code user code length = 3 + n

message mode 3, length variable

distributor code user code 0CH nb. det length = 3 + n + 3

message mode 3, length variable, distributor-code filtering user code 0CH nb. det length = n + 3

message mode 0, length fixed distributor code user code 0DH 0DH ... 0DH length = 37

message mode 3, length fixed

distributor code user code 0CH nb. det 0DH 0DH ... 0DH length = 37

message mode 3, length fixed, distributor-code filtering user code 0CH nb. det 0DH 0DH ... 0DH length = 37

Page 34: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 34/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

6.1.3 Tag code transmission Tag code transmission to host can be modified using two further parameters.

The first is the minimum time between consecutive tag code transmissions (MTBM). This can be set to one of several values (from 100 ms to 1 s), allowing interconnection to readers with different reaction times.

The second is the possibility of repeating the transmission of the tag code. This may be desirable in certain cases. If this option is enabled, the tag code is sent a second time after a time MTBM.

6.2 Wiegand compatible interface

6.2.1 Description Using this interface allows the reader to take the place of a Wiegand-effect card reader. This interface comprises two signals, DATA “0” and DATA “1”. A logical 0 produces a negative pulse on the DATA_0 line and a logical one produces a negative pulse on the DATA_1 line. The timing is given in Figure 6-3 below. The data is transmitted synchronously in a frame format at a rate of roughly 1000 bits/s

1 1 10 0 0 NRZ

DATA "1"

DATA "0"

1.0 mS

50 µS Figure 6-3 : Timing for WIEGAND Interface.

The DATA_0 and DATA_1 signals are open-collector outputs (circuit shown in Figure 10-9). For proper operation a pull-up resistor of about 1K ohm should be used.

6.2.2 Message format The Wiegand message has a fixed length of 26 bits, and the following structure :

bit number - 1 2 9 10 25 26

EP FC CC OP

EP - Even parity bit If the number of ones in the bits 2 to 13 is odd, then this bit is equal to 1, otherwise it is equal to 0.

Page 35: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 35/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

FC - Facility Code

length = 8 bits (bits 2 to 9) A number, 0 to 255, binary-coded using 8 bits, MSB is bit 2.

CC - Card Code

length = 16 bits (bits 10 to 25)

A number, 0 to 65535, binary-coded using 16 bits, MSB is bit 10.

OP - Odd parity bit If the number of ones in the bits 14 to 25 is even, then this bit is equal to 1, otherwise it is equal to 0.

Message transmission begins with bit 1.

6.2.3 Distributor code filtering As well as the user data field, which for Wiegand corresponds to the 26 bit frame described above, the HYPERX tag contains a three character distributor code, provided by BALOGH, which is unique for each installation. This code is automatically added when the tag is first programmed.

When “Distributor code filtering” is enabled, only those tags whose distributor code is identical to the reference distributor code are allowed. The distributor code is not transmitted to the host, it is only used in this case for filtering purposes. The reference distributor code can be defined to be the distributor code contained in the first tag which is detected after a processor reset. It is memorized, and the distributor codes of all succeeding tags are compared to this reference. If they are the same, the tag is allowed, if not the tag is rejected. All readers support this mode. For the LMB, the reference distributor code can also be defined using JBUS commands. Up to 6 different codes can be uploaded into non-volatile memory and any one can be used at any time as the reference code.

The distributor code consists of three ASCII digits, 0 - 9, allowing 1 000 combinations. NOTE for modular and LPR :

For firmware versions till 4.10, this facility is automatically enabled if the Wiegand interface is selected. It can also be enabled for the other interfaces if desired. As of firmware version 4.11, this facility must be enabled by switch/jumper.

6.2.4 Tag code transmission Tag code transmission to host can be modified using two further parameters.

The first is the minimum time between consecutive tag code transmissions (MTBM). This can be set to one of several values (from 100 ms to 1 s), allowing interconnection to readers with different reaction times.

The second is the possibility of repeating the transmission of the tag code. This may be desirable in certain cases. If this option is enabled, the tag code is sent a second time after a time MTBM.

Page 36: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 36/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

7 ASYNCHRONOUS INTERFACE

7.1 Introduction Readers can be connected to a host using either a point-to-point configuration or a multipoint (bus) configuration. Furthermore, two types of protocol are possible : polling by host or interrupt. The interrupt protocol uses either the JBUS™ frame format or the test mode format.

NB : 1. The interrupt protocol should only be used on a point to point link.

2. JBUS™ is registered by APRIL , MODBUS™ is registered by GOULD MODICON

A multipoint or network configuration using the standards for differential data transmission RS-485 (2-wire, 2-way) or RS-422 (4-wire, 2 for each way), is used if several readers are to be interconnected. In this case the polled JBUS protocol is implemented

reader #1 reader #n . . RS-485

HOST22

Figure 7-1 : Network topology using RS-485

reader #1 reader #n . . RS-422

HOST2

2

Figure 7-2 : Network topology using RS-422

If only one reader is to be connected, either of the three standards can be used. In this case either of the two protocols, polled (see chapter 7.3) or interrupt (see chapter 7.4), are possible.

HOSTreader

RS-232 RS-422 RS-485

Figure 7-3 : Point-to-point topology

Page 37: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 37/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

The table below summarizes the different combinations :

Type of connection

Protocol point-to-point multipoint Interrupt RS-232/422/485 — Polling RS-232/422/485 RS-422 or RS-485

7.2 Transmission characteristics All protocols are character-oriented. The character formats are : • 7 bits even parity / 1 stop bit • 7 bits odd parity / 1 stop bit • 8 bits no parity / 1 stop bit Four baud-rates are possible : • 1 200 bauds • 4 800 bauds • 9 600 bauds. • 19 200 bauds Settings are configured by user.

NB : In practice, the JBUS protocol requires 8 bits / no parity. The other formats are used for special situations.

7.3 Reader in Polled Mode This is a master/slave protocol. Each exchange is initiated by the master and consists, except in one case (broadcast message), an exchange of two frames - a command issued by the master and a reply from the slave. All frames have the following structure :

Slave no. function code data control

NB : A HYPER X reader is a JBUS™ slave.

The commands issued by the master are either addressed to one slave (identified by its number or address) or to all slaves on the network (broadcast).

The four fields have the following meanings :

• Slave number (1 byte) : Specifies the destination, from 1 to 11 (1 to 31 for the LMB). If the number is 0, it is a broadcast message. In this case there is no reply.

• function code (1 byte) : Command : Determines the type of action to be performed (read, write, bit, word).

Reply : Result (success or error).

• data field (n bytes): Contains the parameters associated with the function : command code, number of bytes, values.

Page 38: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 38/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

• control field (2 bytes): For error detection (CRC 16) - See chapter 11.

The JBUS™ protocol defines 12 functions (second field in frame). The following four of them are implemented on the HYPERX readers:

• function 3 : read n words

• function 5 : write one bit

• function 6 : write one word

• function 16 : write n words If the message is received with errors (CRC incorrect), the reader does not reply. If the message is received correctly but the reader cannot process it, an error message is sent. This error message has its function code field modified, (the msb is set to 1) and the data field contains one byte, an error code with the following values :

Error code Meaning 1 Function code unknown 2 Command unknown 3 Data incorrect 4 System non ready 8 Execution failure

Table 7-1 : JBUS error codes

Example : PC —> reader 01 03 00 39 00 01 54 07 (incorrect command) reader —> PC 01 83 02 C0 F1 The maximum time allowable between the reception of two characters is a protocol parameter which allows a slave to resynchronise to a frame-start, if transmission is interrupted. If this time is exceeded, the slave rejects the frame currently being received. For the HYPERX reader, this time is equal to 20 ms except in the case of a baud-rate of 1200 bauds for which it is 30 ms.

7.3.1 Write one bit - Command

1 byte 1 byte 2 bytes 1 byte 1 byte 2 bytes Address reader 05 command code bit value 00 CRC 16

- if bit = 0, bit value = 00H, - if bit = 1, bit value = FFH

- Reply 1 byte 1 byte 2 bytes 1 byte 1 byte 2 bytes

Address reader 05 command code bit value 00 CRC 16

Page 39: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 39/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

The’Reply’ frame is identical to the ‘Command’ Frame.

If the address is 00H, all the readers process the command without sending a reply.

7.3.2 Write one word - Command

1 byte 2 bytes 2 bytes 2 bytes Address reader 06 command code value* CRC 16

* A word consists of two bytes, msb first - Reply

1 byte 1 byte 2 bytes 2 bytes 2 bytes Address reader 06 command code value* CRC 16

The’Reply’ frame is identical to the ‘Command’ Frame.

If the address is 00H, all the readers process the command without sending a reply.

7.3.3 Write n words - Command

1 byte 1 byte 2 bytes 2 bytes 1 byte n bytes 2 bytes Address reader 10H command code nbr of

words nbr of

characters values * CRC 16

* words to be written, in order - Reply

1 byte 1 byte 2 bytes 2 bytes 2 bytes Address reader 10H command code nbr of words CRC 16

If the address is 00H, all the readers process the command without sending a reply.

7.3.4 Read n words - Command

1 byte 2 bytes 2 bytes 2 bytes Address reader 03 command code nbr of words CRC 16

- Reply 1 byte 1 byte 1 byte n bytes

Address reader 03 nbr characters read†

values * CRC 16

* bytes read, in order † number of characters read = 2 X number of words in Command (always even)

Page 40: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 40/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

7.4 Reader in Interrupt Mode The format used for tag code transmission in this mode is either ASCII text or a JBUS frame (see below), depending on the user setting. In this mode, as soon as a reader has a message to send to the host (i.e. a tag that has been detected), it sends it, rather than waiting for an invitation, as is the case in the polled mode.

However it is important to realise that the “interrupt” nature of this mode refers only to tag codes. All other JBUS commands can be sent by the host in this mode and the reader will reply. The reader cannot send a reply straight away if it has just detected a tag and has started to send this message. The host must decide if and when it can safely interrogate the reader.

7.4.1 Binary format The message sent has the following structure :

1 byte 1 byte 1 byte n bytes 2 bytes

02 04 nb characters values CRC 16

This structure is the same as that of a ‘reply’ frame to the command read n words. The first field is fixed at 2 (STX) and the second field, the code function, is fixed at 4.

Example : 11 bytes

02 04 0B 30 41 42 43 33 34 35 36 37 38 39 CRC 16

Here, the data field contains 11 bytes. The badge status = ‘0’, the code read is ‘ABC3456789’.

See chapter 8.1.2 for details of the structure of the data field.

The host replies with an ACK or a NAK. The same message is retransmitted up to NE times in case an ACK is not received. If a NAK is received the message is sent again immediately, if no reply is received the message is sent after a 100ms timeout. After NE failed attempts, transmission for that message is abandoned. NE is the "number of emissions" parameter (see §5.3.19).

If, during the initialisation stage after processor reset, a hardware fault is detected, causing the bit MS/CF in the status word to be set, then the init errors frame, providing information about the nature of the fault, is automatically sent. This frame has the following format, where the meaning of the byte values is given in §8.1.7:

2 bytes

02 04 02 Values CRC 16

7.4.2 ASCII formats The first ASCII format (simply called ASCII) produces the following output : <reader_address>.<status_badge>.<distributor_code><user_code>

where

Page 41: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 41/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

reader_address : ‘1’-‘B’ = addresses 1 to 11 (modular and LPR)

: ‘01’-‘31’ = addresses 1 to 31 (LMB) status_badge : ‘0’ = tag battery OK, ‘1’ = tag battery low

distributor_code : ‘nnn’ where n is a digit

user_code : from 1 to 27 characters

The presence of the distributor code depends on the “distributor code filtering” setting.

Examples (modular and LPR):

Message address battery distributor code user code

1.0.001ABCDEF-100 1 OK 001 ABCDEF-100 5.0.123HYPER X.007 5 OK 123 HYPER X.007

B.1.99912345 11 low 999 12345

Examples (LMB):

Message address battery distributor code user code

01.0.001ABCDEF-100 1 OK 001 ABCDEF-100 10.0.123HYPER X.007 10 OK 123 HYPER X.007

31.1.99912345 31 low 999 12345

The second ASCII format (called CODE ONLY) transmits only the user code. For the three cases above, we would get : ABCDEF-100 HYPER X.007

12345

Page 42: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 42/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

8 JBUS/MODBUS Reader Commands N° Command Function

code Command

code Command parameter

Reply parameter LML LPR LMB

1 Get reader status 3 0040 nb words = 1 1 word status_l • • • 2 Get modules status 3 0041 nb words = 1 1 word status_m • • 3 Get tag 3 0042 nb words = n n words tag • • • 4 Turn reader ON / OFF 6 0043 1 word emis • • 5 Relay control 5 0044 1 bit ( 0 =enable ) 1 bit ( 0 =enable ) • • 6 Reset reader 5 0045 1 bit ( 0 =reset ) • • • 7 Persistence time 6 0046 1 word time • • • 8 Antenna LED control 6 0047 1 word led • • • 9 Get previous tag 3 0048 nb words = n n words • • •

10 Read firmware version 3 0049 nb words = 1 1 word version • • • 11 Get config 3 004A nb words = 10 10 words config • • • 12 Write config 16 004B 10 words config • • • 13 Inject code (test) 16 004C • • • 14 Get init errors 3 004F nb words = 1 1 word status_e • • • 15 Select channel 6 0050 1 word channel • • 16 Buzzer 5 0051 1 bit ( 0 = ON ) • 17 Write outputs 6 0052 1 word outputs • 18 Read inputs 3 0053 nb words = 1 1 word inputs • 19 Load distributor code 16 0023 2 words ci • 20 Enable distributor code 6 0025 1 word no_ci • 21 Read distributor code 3 0027 nb words = 2 2 words ci • 22 Get status mem_tags 3 0054 nb words = 8 8 words status_mem_tags • 23 Get mem_tags 3 008x nb words = n n words mem_tags • 24 Get reader type 3 0055 nb words = 1 I word reader • 25 Set power level 6 0056 nb words = 1 I word niveau • 26 Set range 6 0057 nb words = 1 I word portee • 27 Get date 3 0060 nb words = 3 3 words date • 28 Set date 16 0061 3 words date • 29 Get log status 3 0062 nb word s = 1 1 word status_j • 30 Get log record 3 0063 nb words = n n words record • 31 Get previous log record 3 0064 nb words = n n words record • 32 Reset log address 5 0065 1 bit ( 0 =reset ) • 33 Clear log 16 0066 nb words = 1 • 34 Get max length (log) 3 0067 nb words = 1 1 word len_max • 35 Get current length (log) 3 0068 nb words = 1 1 word len_cur • 36 Get nb records (log) 3 0069 nb words = 1 • 37 Get serial number 3 0070 nb words = 3 3 words sn •

Table 8-1 : Summary of all JBUS commands

Page 43: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 43/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

8.1 Commands for all readers N° Command Function

code Command

code Command parameter

Reply parameter

1 Get reader status 3 0040 nb words = 1 1 word status_l 3 Get tag 3 0042 nb words = n n words tag 6 Reset reader 5 0045 1 bit ( 0 =reset ) 7 Persistence time 6 0046 1 word time 8 Antenna LED control 6 0047 1 word led 9 Get previous tag 3 0048 nb words = n n words

10 Read firmware version 3 0049 nb words = 1 1 word version 11 Get config 3 004A nb words = 10 10 words config 12 Write config 16 004B 10 words config 13 Inject code (test) 16 004C 14 Get init errors 3 004F nb words = 1 1 word status_e

Table 8-2 : JBUS commands common to all readers

8.1.1 Get reader status This is a command of type read n words, code = 0040H. If the command parameter nb words is not equal to 1, the reader replies with the JBUS error 3 (Data incorrect).

The reader returns one word (two bytes, MSbyte first).

For modular and LPR :

D15 D8 D7 D0 BA 0 N5 N4 N3 N2 N1 N0 UC AM DP CF DM E2 E1 RE

bit name modular reader compact reader D15 BA 0 = 1 tag has been read,1 = two or more tags have been read

D13-D8 N5 .. N0 number of characters in tag (1 to 34), binary-coded in 6 bits D7 UC User config, one or more parameters have been changed via a JBUS command

(active 1) D6 AM Fault in Power supply module 1 D5 DP Tag memory overflow D4 CF Critical hardware fault D3 DM Fault in one of the external modules D2 E2 Radio reception enabled for Antenna 2 1 D1 E1 Radio reception enabled for Antenna 1 D0 RE Relay activated

- NB : When not specified, the bits are active low.

The length specified by the bits N5 … N0 includes one byte for the tag’s status, three for the distributor code and the rest for the user-code (see chapter 8.1.2). This number may be even or odd. However, when using the command read n words in order to read a tag-code, an even number of words must be specified and the reply always contains an even number of bytes, the last of which may not be significant.

Page 44: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 44/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

If either of the bits AM or DM are active, the host should issue the command read modules status (chapter 8.2.1) in order to determine the cause. If the bit MS is active, the host should issue the command read init errors (chapter 8.1.7). Example : PC —> reader 01 03 00 40 00 01 85 DE reader —> PC 01 03 02 00 7D 78 65

For LMB : D15 D8 D7 D0 BA 0 N5 N4 N3 N2 N1 N0 E2 E1 OV CF NF SR EE BP

Bit name Description D15 BA 0 = 1 tag has been read,1 = two or more tags have been read

D13-D8 N5 .. N0 number of characters in tag (1 to 34), binary-coded in 6 bits D7 E2 State of input 2 D6 E1 State of input 1 D5 OV Tag memory overflow (active 0) D4 CF Critical hardware fault (active 0) D3 NF Non-critical hardware fault (active 0) D2 SR State of reader (1 = initialised, 0 = non-initialised) D1 EE State of EEPROM (1 = OK, 0 = error) D0 BP 1 = one or more tags present in front of antenna

8.1.2 Get tag This is a command of type read n words, code = 0042H. If the number of words to be read (see 0) is different from the number of words available (see command get reader status) , the reader replies with the JBUS error 8 (execution failure). This error is also produced if no tags are present.

The data field structure of the ‘reply’ frame is as follows : 1 byte 3 bytes 1 to 30 bytes

status_tag distributor_code user_code The length of this field can vary from a minimum of 5 to a maximum of 34. The distributor code may not be present if distributor-code filtering is enabled.

Only two bits of status_tag are used :

D7 D1 D0 0 0 1 1 0 0 X X

D0 : tag battery (0 = OK, 1 = low) D1 : Antenna number ( 0 = antenna 1 / SAM1, 1 = antenna 2 / SAM2 ) - for modular reader

only For modular readers :

Page 45: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 45/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

• Antenna 1 is connected to the receiver module SAM1 (immediately to left of SPI in rack)

• Antenna 2 is connected to the receiver module SAM2 (leftmost SAM in a double rack). The user-code can vary in length from 1 to 30 characters. It consists of any ASCII characters whose ASCII codes lie between 20H and 5FH.

Example : PC —> reader 01 03 00 42 00 04 E4 1D reader —> PC 01 03 08 30 31 32 33 39 39 39 39 C5 B8

8.1.3 Reset reader This is a command of type write one bit, code = 0045H. If the parameter byte contains 0, an internal processor reset is generated. Any other value produces the JBUS error 3 (data incorrect).

Example : PC —> reader 01 05 00 45 00 00 DC 1F (reset) reader —> PC 01 05 00 45 00 00 DC 1F

8.1.4 Tag Persistence This is a command of type write one word, code = 0046H. One word (two bytes) must be sent, the most significant byte first.

For modular and LPR : This time is expressed as a multiple of 50ms and binary-coded using 11 bits, giving a range from 50ms to 100 seconds.

time D15 D8 D7 D0

x x x X x T10 T9 T8 T7 T6 T5 T4 T3 T2 T1 T0

If a value of 0 is programmed, then the reader will send the tag-code at each detection. This is incompatible with several reader configurations and must be used with caution.

If this command is successfully executed by the reader, then the UC bit in the status word status_l is set to 1.

Example : PC —> reader 01 06 00 46 00 28 68 01 (time = 2s) reader —> PC 01 06 00 46 00 28 68 01 For LMB only :

Only 3 bits in the first byte are valid, they code for the same value as in Table 5-1.

Example : PC —> reader 01 06 00 46 03 00 68 01 (time = 2s) reader —> PC 01 06 00 46 03 00 68 01

8.1.5 Antenna LED control This is a command of type write one word, code = 0047H. One word (two bytes) must be sent, the most significant byte first.

Page 46: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 46/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

led D15 D8 D7 D0

NA RV CF AE T3 T2 T1 T0 x x x x x x x x

NA : N° antenna ( 0 = antenna 1, 1 = antenna 2 ) ( =0 for compact reader) RV : 0 = LED red, 1 = LED green CF : 0 = blink, 1 = fixed AE : 0 = on, 1 = off T3 .. T0 : Blink period (on or off-time) as multiple of 50ms binary-coded using 4 bits. Thus : 0001 : 50ms / 50 ms 0010 : 100ms / 100 ms 0011 : 150ms / 150 ms . 1111 : 750ms / 750 ms If this command is successfully executed by the reader, then the UC bit in the status word status_l is set to 1.

Example : PC —> reader 01 06 00 47 05 00 3A 8F (led ant 1 blinks red 250/250ms) reader —> PC 01 06 00 47 05 00 3A 8F

8.1.6 Read previous tag This is a command of type read n words, code = 0048H. If the number of words to be read (chapter 0) is different from the number of words available, the reader replies with the JBUS error 8 (execution failure). This error is also produced if no tags are present.

This command makes the reader retransmit the previous tag code, providing no other transmission has occurred since. It is used in polling mode if the reader’s reply contains errors and the host wishes a retransmission. In such a case, repeating the command read tag is of no use, this command must be used. The number of words to be read must be the same as that used in the previous read tag command.

Example : PC —> reader 01 03 00 42 00 03 A5 DF (read 3 words) reader —> PC 01 03 06 01 02 03 04 05 16 9B B3 (CRC incorrect) PC —> reader 01 03 00 48 00 03 85 DD (retransmit 3 words) reader —> PC 01 03 06 01 02 03 04 05 06 9B B3 (CRC OK)

8.1.7 Get Init Errors This is a command of type read n words, code = 004FH. If the command parameter nb words is not equal to 1, the reader replies with the JBUS error 3 (Data incorrect).

The reader returns one word status_e (two bytes, MSbyte first).

After a manual reset, the reader performs an internal test of its major hardware elements. If an error is detected, the CF bit in the reader status word is set (see 0) and the reader resets itself after 4 seconds and continues to do so until the fault disappears. This command, if sent after the end of the test (the

Page 47: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 47/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

buzzer sounds while the test is in progress), will determine the nature of the fault. One word status_e is to be read: For modular and LPR

Only the 5 bits D0 to D4 are used :

status_e D15 D8 D7 D0

x x x x x x x x x x x SCC SCB SCA RAM ROM

Bit Description

ROM EPROM checksum is incorrect RAM RAM failure SCA SCC channel A failure SCB SCC channel B failure SCC SCC bus access failure

Table 8-3 : Init error code for LPR and modular reader

The bits are active 1.

Example : PC —> reader 01 03 00 4F 00 01 B5 DD reader —> PC 01 03 02 00 00 B8 44 (no errors) For LMB

Only the first byte contains the error codes :

D7 D0 RTC ESN IRS SCCA SCB EEP RAM ROM

Bit Description ROM Error FLASH checksum RAM Error external RAM EEP Error EEPROM SCB Error SCC Bus

SCCA Error SCC IRS Error serial interface ESN Error serial number RTC Error RTC

Table 8-4 : Init error code for LMB

8.1.8 Get EPROM version This is a command of type read n words, code = 0049H. If the command parameter nb words is not equal to 1, the reader replies with the JBUS error 3 (Data incorrect).

Page 48: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 48/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

The reader returns one word version (two bytes, MSbyte first).

version identifier major index minor index minor index

D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0

Reader type identifier

Modular 0 LPR 5 LMB 6

Thus, version = 0401H indicates a modular reader with EPROM version 4.01. Version = 5403H indicates a compact reader with EPROM version 4.03.

Example :

PC —> reader 01 03 00 49 00 01 55 DC reader —> PC 01 03 02 61 07 D0 16 (LMB version 1.07)

8.1.9 Get Config This is a command of type read n words, code = 004AH. If the command parameter nb words is not correct, the reader replies with the JBUS error 3 (Data incorrect).

Modular and LPR

The reader returns two bytes corresponding to the states of the two sets of switches. The first byte corresponds to the Address switches, the second to the Mode switches. Zeros correspond to switches in the ON position (see chapter 3 for description of switch positions). LMB

For firmware versions up to v1.04, 26 bytes must be read. Each byte corresponds in order to the value of the parameter of that number (byte 1 corresponds to parameter 1 etc). See Table 5-1.

Example :

PC —> reader 02 03 00 4a 00 0d a5 ea (read 13 words) reader —> PC 02 03 1a 00 63 02 01 00 00 00 00 00 03 01 00 02 03 00 03 00 00 02 03

03 03 07 00 00 00 2a 79 For firmware versions as of v1.07, 28 bytes must be read (as these versions have 2 additional parameters).

8.2 Special commands for the modular reader N° Command Function

code Command

code Command parameter

Reply parameter

2 Get modules status 3 0041 nb words = 1 1 word status_m 4 Turn reader ON / OFF 6 0043 1 word emis 5 Relay control 5 0044 1 bit ( 0 =enable ) 1 bit ( 0 =enable )

Page 49: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 49/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

8.2.1 Get modules status This is a command of type read n words, code = 0041H. If the command parameter nb words is not equal to 1, the reader replies with the JBUS error 3 (Data incorrect). The reader returns one word status_m (two bytes, MSbyte first).

status_m bit name description D15 DCH Battery-charger fault D14 DAC Mains fault D13 DDC Battery backup fault D12 DTE External DC input voltage fault D11 PSHF2 Microwave source module HF2 present D10 PSHF1 Microwave source module HF1 present D9 PCMR2 Module SAM2 present D8 PCMR1 Module SAM1 present D7 unused 1 D6 unused 1 D5 ERV2 Phase-lock error source HF 2 D4 ERV1 Phase-lock error source HF 1 D3 ERS2 Fault in module HF 2 D2 ERS1 Fault in module HF 1 D1 PEM2 Microwave power present on SAM2 D0 PEM1 Microwave power present on SAM1

- NB : All bits are active low.

Example : PC —> reader 01 03 00 41 00 01 D4 1E reader —> PC 01 03 02 FA FE 7B 64

8.2.2 Turning reader ON / OFF This command turns the microwave emission on or off. This is a command of type write one word, code = 0043H. One word (two bytes) must be sent, the most significant byte first. D15 D8 D7 D0 NA x x x x x x x x x x x x x x VE

NA : N°. antenna ( 0 = antenna 1, 1 = antenna 2 ) VE : Enable emission ( 0 = enable, 1 = disable )

If this command is successfully executed by the reader, then the UC bit in the status word status_l is set to 1.

Example : PC —> reader 01 06 00 43 00 01 B9 DE reader —> PC 01 06 00 43 00 01 B9 DE

Page 50: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 50/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

8.2.3 Relay control This is a command of type write one bit, code = 0044H. If the parameter byte contains 0 the relay is energised, if it contains FFH, the relay is de-energised. If this command is successfully executed by the reader, then the UC bit in the status word status_l is set to 1.

Example : PC —> reader 01 05 00 44 00 00 8D DF (energise relay) reader —> PC 01 05 00 44 00 00 8D DF

8.3 Special commands for the LPR N° Command Function

code Command

code Command parameter

Reply parameter

2 Get modules status 3 0041 nb words = 1 1 word status_m 5 Relay control 5 0044 1 bit ( 0 =enable ) 1 bit ( 0 =enable )

15 Set channel 6 0050 1 word channel

8.3.1 Get modules status This is a command of type read n words, code = 0041H. If the command parameter nb words is not equal to 1, the reader replies with the JBUS error 3 (Data incorrect).

The reader returns one word status_m (two bytes, MSbyte first).

status_m bit name description D15 unused 1 D14 unused 1 D13 unused 1 D12 unused 1 D11 unused 1 D10 unused 0 D9 unused 1 D8 unused 0 D7 unused 1 D6 unused 1 D5 unused 1 D4 unused 1 D3 unused 1 D2 unused 1 D1 unused 1 D0 PEM1 Microwave power present

- NB : All bits are active low.

8.3.2 Relay control This is a command of type write one bit, code = 0044H. If the parameter byte contains 0 the relay is energised, if it contains FFH, the relay is de-energised.

Page 51: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 51/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

If this command is successfully executed by the reader, then the UC bit in the status word status_l is set to 1. Example : PC —> reader 01 05 00 44 00 00 8D DF (energise relay) reader —> PC 01 05 00 44 00 00 8D DF

8.3.3 Set channel number This is a command of type write one word, code = 0050H. One word (two bytes) must be sent, the most significant byte first.

This command lets the user select one of 29 operating frequencies.

channel

D15 D8 D7 D0 0 0 0 0 0 0 0 0 0 0 0 C4 C3 C2 C1 C0

Bits C4..C0 code the channel number. Channel 0 is not used. If this value, or a value greater than the maximum value is programmed, the reader replies with the JBUS error 3 (Data incorrect).

Channel C4 C3 C2 C1 C0

0 not used 1 0 0 0 0 1 2 0 0 0 1 0 29 1 1 1 0 1

The correspondence between channel number and microwave frequency is given in chapter 12.

Example : PC —> reader 01 06 00 50 00 09 49 DD (set channel 9) reader —> PC 01 06 00 50 00 09 49 DD

Page 52: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 52/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

8.4 Special commands for the LMB N° Command Function

code Command

code Command parameter

Reply parameter

15 Select channel 6 0050 1 word channel 16 Buzzer 5 0051 1 bit ( 0 = ON ) 17 Write outputs 6 0052 1 word outputs 18 Read inputs 3 0053 nb words = 1 1 word inputs 19 Load distributor code 16 0023 2 words ci 20 Enable distributor code 6 0025 1 word no_ci 21 Read distributor code 3 0027 nb words = 2 2 words ci 22 Get status mem_tags 3 0054 nb words = 8 8 words status_mem_tags 23 Get mem_tags 3 008x nb words = n n words mem_tags 24 Get reader type 3 0055 nb words = 1 I word reader 25 Set power level 6 0056 nb words = 1 I word niveau 26 Set range 6 0057 nb words = 1 I word portee 27 Get date 3 0060 nb words = 3 3 words date 28 Set date 16 0061 3 words date 29 Get log status 3 0062 nb word s = 1 1 word status_j 30 Get log record 3 0063 nb words = n n words record 31 Get previous log record 3 0064 nb words = n n words record 32 Reset log address 5 0065 1 bit ( 0 =reset ) 33 Clear log 16 0066 nb words = 1 34 Get max length (log) 3 0067 nb words = 1 1 word len_max 35 Get current length (log) 3 0068 nb words = 1 1 word len_cur 36 Get nb records (log) 3 0069 nb words = 1 37 Get serial number 3 0070 nb words = 3 3 words sn 38 Perform auto-diagnostic 3 005A nb words = 11

8.4.1 Set channel number This is a command of type write one word, code = 0050H. One word (two bytes) must be sent, the most significant byte first. This command lets the user select one of 31 operating frequencies.

channel D15 D8 D7 D0

0 0 0 0 0 0 0 0 0 0 0 C4 C3 C2 C1 C0

Bits C4..C0 code the channel number. Channel 0 is not used. If this value, or a value greater than the maximum value is programmed, the reader replies with the JBUS error 3 (Data incorrect).

Channel C4 C3 C2 C1 C0 0 not used 1 0 0 0 0 1 2 0 0 0 1 0 31 1 1 1 1 1

The correspondence between channel number and microwave frequency is given in chapter12.

Page 53: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 53/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

Example : PC —> reader 01 06 00 50 00 09 49 DD (set channel 9) reader —> PC 01 06 00 50 00 09 49 DD

8.4.2 Buzzer

Allows buzzer control identical to the buzzer parameter (§5.3.4). Only the first of the 2 bytes are valid, if the byte = 0, the buzzer is enabled, otherwise it is disabled.

Example :

PC —> reader 01 05 00 51 01 00 9D 8B (turn buzzer off) reader —> PC 01 05 00 51 01 00 9D 8B

8.4.3 Write outputs Allows writing the 2 outputs S1 and S2. The first byte selects the output(s), the second selects the state.

D15 D8 D7 D0

x x x x x x S2 S1 0 0 0 x x x A2 A1

S1 : 1 = output S1 S2 : 1 = output S2 A1 : 0 = deactivate, 1 = activate S1 A2 : 0 = deactivate, 1 = activate S2

Examples :

PC —> reader 02 06 00 52 01 01 E8 78 (activate output 1) reader —> PC 02 06 00 52 01 01 E8 78

PC —> reader 02 06 00 52 02 00 29 48 (deactivate output 2) reader —> PC 02 06 00 52 02 00 29 48 PC —> reader 02 06 00 52 03 03 68 D9 (activate outputs 1 and 2) reader —> PC 02 06 00 52 03 03 68 D9

Note : in order to be able to write to the outputs, the outputs parameter must be in the "host control" setting.

8.4.4 Read Inputs Allows reading the state of the 2 inputs. Two bytes are read:

D15 D8 D7 D1 D0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 E2 E1

E1 : 0 = input E1 activated, 1 = input E1 deactivated (see §9.1) E2 : 0 = input E2 activated, 1 = input E2 deactivated (see §9.1)

Page 54: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 54/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

Example : PC —> reader 01 03 00 53 00 01 74 1B reader—> PC 01 03 02 00 03 F8 45 (both inputs deactivated)

8.4.5 Load Distributor code Allows loading a distributor code (up to 6 are allowed) into the reader's non-volatile memory. This code can then be used for distributor code filtering.

3 words (6 bytes) with the following structure are written: byte 1 byte 2 byte 3 byte 4 byte 5 byte 6

NO IC1 IC2 IC3 IC4 0 NO : index, 0 to 5 (0 for first distributor code, 1 for second etc) IC1 : 1st character of distributor code IC2 : 2nd character of distributor code IC3 : 3rd character of distributor code IC4 : always 0 Last byte = 0

Example :

PC —> reader 01 10 00 23 00 03 06 00 31 32 33 00 00 94 96 reader —> PC 01 10 00 23 00 03 71 C2

8.4.6 Enable Distributor code Allows enabling a particular distributor code for filtering. The code must already have been loaded into memory with the previous command. Two bytes must be written, the first identifies the code (0 to 5), the second specifies whether filtering is to be enabled (0) or disabled (1).

Example :

PC —> reader 01 06 00 25 00 00 98 01 reader —> PC 01 06 00 25 00 00 98 01

8.4.7 Get Distributor code Reads the current distributor code used for filtering. If no filtering is present, an error code is returned. Four bytes are read :

byte 1 byte 2 byte 3 byte 4 IC1 IC2 IC3 IC4

IC1 : 1st character of distributor code IC2 : 2nd character of distributor code IC3 : 3rd character of distributor code IC4 : always 0

Page 55: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 55/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

If several distributor codes have been enabled for filtering, this command returns the distributor code with the highest number e.g. if distributor codes 1 and 3 are enabled, then this command will return distributor code 3. Note that the four bytes returned are in the modified ASCII format, ASCII-20H, thus 20H needs to be added to each byte to produce the correct ASCII character.

Example :

PC —> reader 01 03 00 27 00 02 74 00 reader —> PC 01 03 04 11 12 13 00 52 3A ('123')

8.4.8 Get status of tags in memory Allows determining if any tags are present in the reader's memory. As long as a tag is detected by the reader (buzzer emits a short beep at each detection) it remains in memory. It is stored in one of 16 memory locations. This command returns, for each memory location, a status byte containing a numerical value n. If no tag is present n=0, otherwise a tag of length n bytes is present. (same definition of length as for the "get status" 0 command).

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

n1 n2 n3 n4 n5 n6 n7 n8 n9 n10 n11 n12 n13 n14 n15 n16

Example :

PC —> reader 01 03 00 54 00 08 05 DC reader —> PC 01 03 10 0D 21 00 00 00 00 00 00 00 00 00 00 00 00 00 00 C1 D4

8.4.9 Get tag in memory Returns the the tag code present in the specified internal memory location. The length parameter that must be supplied is given by the value returned by the "get status of tags in memory" command. If the tag disappears in the meantime (in the time between the execution two commands) the reader replies with an error code. In order to read at memory location 1, the command code 80H is used, for memory location 2, 81H etc till location 16, 8FH.

Example :

PC —> reader 01 03 00 80 00 07 05 E0 reader —> PC 01 03 0E 30 30 30 30 31 31 31 30 30 30 30 30 32 00 84 7E

8.4.10 Get reader type Determines the reader type – returns one word, only the first byte of which is significant.

type reader 1 6011 2 6012 3 6013 4 6034 5 6035 6 7023 7 6033

Table 8-5 : LMB Reader types

Page 56: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 56/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

Example : PC —> reader 01 03 00 55 00 01 94 1A reader —> PC 01 03 02 06 00 BB E4 (7023)

8.4.11 Set range Allows (very roughly) fixing the reader's range by adjusting the receiver threshold voltage. Two bytes are written, the second is ignored.

D15 D8 D7 D1 D0 x x x x x x P1 P0 x x x x x x x x

P1..P0 range 00 few cms 01 minimum 10 medium 11 maximum

Example :

PC —> reader 01 06 00 57 02 00 39 7A (set range to medium) reader —> PC 06 00 57 02 00 39 7A

8.4.12 Get Date

Returns the reader's date. Six bytes are returned in the following order :

1 byte 1 byte 1 byte 1 byte 1 byte 1 byte seconds minutes hours day month year

Each byte is BCD.

Example :

PC —> reader 02 03 00 60 00 03 05 e6 (read 3 words) reader —> PC 02 03 06 48 36 09 13 04 01 c3 50 (09:36:48,13 april 2001)

8.4.13 Set Date

Allows setting the date and time of the reader. Six bytes are sent in the following order :

1 byte 1 byte 1 byte 1 byte 1 byte 1 byte seconds minutes hours day month year

Each byte is BCD.

Example :

PC —> reader 02 10 00 61 00 03 06 13 10 10 13 04 01 44 5d (10:10:13,13 april 2001) reader —> PC 02 10 00 61 00 03 d1 e5

Page 57: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 57/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

8.4.14 Get log status

Returns 2 bytes in the following order : 1 byte 1 byte

bits 2 6 status nb to read (msb) nb to read (lsb)

The 2 msb of the first byte give the log status :

status description 0 empty 1 Page 0 filling up 2 Page 1 filling up 3 Both pages full

The remaining 6 bits and the 8 bits of the second byte form a binary-coded 14-bit decimal number indicating the number of records remaining to be read (this depends on the position of the current address pointer.

PC —> reader 01 03 00 62 00 01 25 D4 reader —> PC 01 03 02 40 7E 09 A4 (Page 0 filling up, 126 records to read)

8.4.15 Get current record

Allows reading the current record. The length must be specified, this is obtained with the command "read current length" (see §8.4.20) and this value must be incremented by one. The bytes read have the following structure :

3 3 1 n 1 time date type message cs

time : seconds / minutes / hours BCD date : day / month / year BCD type : 0 = badge, 1 = reset, 2 = error message : tag code or error message (there is no message in the case of a reset) cs : 00 = checksum ok, FF = checksum bad

Example :

For the record : FF 06 44 15 04 02 01 08 00 4E 30 31 32 33 35 35 35 D1,

the command "read current record length" returns the value 15. The command "read current record" must then specify a length of 16 and will return:

06 44 15 04 02 01 00 4E 30 31 32 33 35 35 35 00

Example :

PC —> reader 02 03 00 63 00 04 b4 24 (read 4 words) reader —> PC 02 03 08 23 35 16 12 04 01 01 00 56 08 (Reset on 16:35:23,12 april 2001)

Page 58: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 58/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

8.4.16 Get previous record

Sending the command "read current record" causes the address pointer to be moved one record back (in time) – this allows efficient reading of log records. However, it may be necessary to repeat the reading of a record. This command answers that need, it moves the address pointer forward (in time), sends the record, then moves it back again. The address pointer hasn't moved, so this command does not allow reading records backwards. The length parameter must be same as that used in the "read current record " command :

PC —> reader 01 03 00 64 00 04 05 D6 reader —> PC 01 03 08 32 28 10 07 08 02 01 00 AA 78

8.4.17 Reset log address

This command moves the address pointer back to the most recent record. This allows recommencing the log reading. This command requires the first byte =0.

Example :

PC —> reader 02 05 00 65 00 00 dd e6 reader —> PC 02 05 00 65 00 00 dd e6

8.4.18 Clear log

This command will delete the entire contents of the log. It may take a few seconds.

Example :

PC —> reader 02 10 00 66 00 01 02 43 03 ca 57 reader —> PC 02 10 00 66 00 01 e1 e5

8.4.19 Get max record length

Determines the length of the longest record. The first byte contains the value, the second is 0.

Example :

PC —> reader 02 03 00 67 00 01 35 e6 (read 1 word) reader —> PC 02 03 02 2a 00 e3 24 (42)

8.4.20 Get current record length

Returns the length of the current record. This value must be incremented by one and used as the length parameter in the "get current record" command (see §8.4.15). The first byte contains the value, the second is 0.

Example :

PC —> reader 02 03 00 68 00 01 05 e5 (read 1 word) reader —> PC 02 03 02 07 00 fe 74 (7+1)

Page 59: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 59/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

8.4.21 Get number of records

Returns the number of records present in the log. An integer value coded as 2 bytes (msb first) is returned.

Example :

PC —> reader 02 03 00 69 00 01 54 25 (read 1 word) reader —> PC 02 03 02 0b b6 7a c2 (2998 = 0xbb6)

8.4.22 Get serial number

Returns the reader's electronic serial number. Six bytes are returned in the following order :

1 byte 1 byte 1 byte 1 byte 1 byte 1 byte sn[5] sn[4] sn[3] sn[2] sn[1] sn[0]

Example :

PC —> reader 02 03 00 70 00 03 04 23 reader —> PC 02 03 06 fe a2 00 07 00 00 68 43

8.4.23 Perform Autodiagnostic This command performs an internal test which checks tag detection. The test checks antenna operation, checks that the correct antenna is installed (in the case of external antennas), and verifies tag detection with an internally generated code burst produced by the antenna. This test is only available with the 7023 reader. The test can take up to 100ms to perform, so the host system must wait at least this long for a reply from the reader. The reader replies with one word (2 bytes), only the first byte of which is significant : status byte:

7 0 L A R n n n n n

L = reader state, 0 = error, 1 = OK A = antenna type, 0 = incorrect, 1 = correct R = reserved nnnnn = antenna identifier Examples : 00000000 : reader error 00001000 : test not allowed (not a 7032) 100nnnnn : reader OK, wrong antenna nnnnn 110nnnnn : reader OK, antenna nnnnn OK

Example :

PC —> reader 01 03 00 5A 00 01 DE 85 reader —> PC 01 03 02 C2 00 xx xx (test OK)

Page 60: Reader Interface Manual

Langue/ Language GB

CE DOCUMENT EST LA PROPRIÉTÉ DE BALTHIS DOCUMENT IS BALOGH PROPERTY.IT

9 DIGITAL I/O (LMB only)

9.1 Digital Inputs

There are two identical inputs. Each input circuit shown below is isolated from reader electronics by an optocoupler. An open-circuit or a voltage less than 6V applied between EI and GND produces an internal 1 logic state. A voltage above 6V will produce an internal 0 logic state. The inputs are read and states updated every 10 ms. The status shows up in the reader status (see §8.1.1).

Input voltage Internal logic state Yellow led < 6 V 1 (inactive) ON > 6 V 0 (active) OFF

These inputs can be used to globally enable or disable all tag reading using an external signal.

9.2 Digital Outputs

There are two identical outputs. Each output circuit shown below is isolated from reader electronics by an optocoupler.

Connector JR4

LMB

Zener12V

optoEI1 (EI2)

GND1 (GND2)

yellow/jaune

optocoupler

VI1 (VI2)

SIC1 (SIC2)

SIE1 (SIE2)

Connector JR3

LMB

CTP

yellow led

Figure 9-1 : Circuit diagram for digital input

REF

Numéro1

OGH IL NE PEUT ETRE C CANNOT BE DISCLOSED

Figure 9-2 : Circuit diagram of digital output stage

ERENCE DU DOCUMENT / DOCUMENT REFERENCE

/ Number Code Doc. / Doc. Code Indice / Revision Index Pages 3053 104 C 60/70OMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

Page 61: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 61/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

This output circuit is designed to work with relays. The relay coil (or other load) is connected between VI and SIC. An external DC voltage applied to VI (12 to 24 VDC) must be able to supply the current needed for the relay coil. The output transistor is turned on (thus allowing current to flow through the relay coil) when a "1" is written to the output. The yellow led is on.

Writing a "0" will turn the relay off. The yellow led is off.

The output can supply roughly 100mA and can drive a 12V or a 24V relay.

Page 62: Reader Interface Manual

Langue/

CE DOCUMENT ESTHIS DOCUMENT

10 EXTERNAL CONNECTIONS

10.1 Connectors

10.1.1 LMB

10.1.2

Figure 10-1 : Connector layout for LMB

8 8

JR4(IN)

JR3(OUT)

JR2(OC)

JR1(RS)12

VDC

-24V

DC

+1

1 1-2

2 23 4 1 2 3 4 5 6

3 4 5 3 4 5

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 62/70T LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE.

IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

LPR

(RELAIS)JP1

12VD

C

+ 1- 2 3 1 2 3 4 5

JP2(RS & CO)

Figure 10-2 : Connector layout for LPR

Page 63: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 63/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

10.1.3 LML

12345

123

RELAIS

LIAISONSRS & CO

SPI

Figure 10-3 : SPI front panel with connectors

10.2 Asynchronous link

The pins are associated with different signals, depending on the type of link used. For the LMB, the JR1 connector is used, for the other readers it is the sole 5-pin connector.

pin RS-232 RS-422 RS-485 1 TX TX+ + V 2 — TX- - V 3 — RX+ — 4 RX RX- — 5 GND GND GND

The following figures show how to connect the reader for RS-232, RS-422 and RS-485.

Page 64: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 64/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

Reader

TX

RX

RX

TX

GND

1

4

5

ConnectorJR1

5

3

2

GND

PC

COM port subD 9

Figure 10-4 : RS232 connection to reader

Reader

ConverterRS232/RS422

TX+TX-RX+RX-

RX+RX-TX+TX-

PC

GND

12

45

3

Connector JR1

Figure 10-5 : RS422 connection to reader

Reader

EquipmentRS485

TX+TX-RX+RX-

+-

GND

12

45

3

Connector JR1

Figure 10-6 : RS485 connection to reader

10.2.1 Cables for RS-422 and RS-485 • Clean environments - twisted pairs, without screen.

• Noisy environments - twisted pairs, individual screen for each pair

Each cable is characterised by :

• its characteristic impedance (Z0 in ohms)

• its distributed capacity (CL in pF/m).

Page 65: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 65/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

• its distributed resistance (RL in ohms/m) For short cable lengths, normal cables are satisfactory.

For cable lengths greater than 1000 metres, high quality cables (low CL and RL) should be used for all baud rates.

10.2.2 Line Termination For a simplex link, the termination (if present) should be placed at the receiving end of the line.

For a duplex link, the termination (if present) should be placed at the each end of the line. For baud rates less than 1200 bauds, no termination is necessary. For baud rates greater than 9600 bauds and line lengths greater than 1000 metres, a resistor equal to the line impedance (120 ohms) is usually necessary. For cases in-between, there is no clear-cut rule and depends on individual installations (combination of baud-rate, line-length, cable quality, emitter/receiver characteristics).

10.2.3 Electrical connections For an RS-232 link , wiring up is straightforward, the TX and RX lines of both equipments are connected together.

For a differential link (RS-422 or RS-485), the polarities are not always clearly defined. Normally the “+” line is at a high level at rest and is active low. For the “-” line, the opposite is true. This is the case for the differential interface for the HYPERX readers. However if the differential signals are generated by a converter acting on RS-232 signals, then the “+” line can be at a low level at rest and active high. In this case, the “+” line of one equipment must be connected to the “-” line of the other equipment.

Connection of 0V Whether this is necessary or not, depends on the installation. If host and reader are distant with different local ground potentials, then an RS-232 link may not work if the 0V references are not connected. However connecting them will cause ground currents to circulate. In general, for large link lengths, a differential link should be used. This also tolerates a large common-mode voltage difference.

10.2.4 Networking Topologies The preferred topology is the bus.

Page 66: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 66/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

L

R

R : line-matching resistor, added if needed

Figure 10-7 : Simplex link

L

RR

R : line-matching resistors, added if needed

Figure 10-8 : Half duplex link

The length of the derivation should be as short as possible (< 30 cm).

The maximum length allowed can be calculated from the cable characteristics using the equation below.

L < 1300 / (Z0 x CL) L in metres, ZO in ohms and CL in pF/m

Line biasing For RS-485, line biasing may prove necessary and must be done externally and only at one point on the line.

The line “+” is connected to +5V via a 4K7 resistor.

The line “-” is connected to 0V via a 4K7 resistor.

10.3 Open-collector interface Both the ISO2 and the WIEGAND interfaces use an Open-collector interface. The output circuit (on the HYPERX readers) is shown in Figure 10-9. For correct operation, pull-up resistors (typical values are 1K) must be connected to any voltage supply between 5V and 12V. For the ISO2 interface, this concerns the three signals STROBE, MDATA and PRES_BADGE, for the WIEGAND interface this concerns the two signals DATA1 and DATA0. See chapter 10.1 for connector pins. Interconnection with HYPERX readers is shown below :

The pins are associated with different signals, depending on the type of link used. For the LMB, the JR2 connector is used, for the other readers it is the sole 5-pin connector.

Page 67: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 67/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

pin ISO2 WIEGAND 1 STROBE DATA “1” 2 MDATA DATA “0” 3 PRES_BADGE — 4 Valim Valim 5 GND GND

Note : the Valim on pin 4 is internally connected to the supply voltage.

Figure 10-9 : Circuit diagram for Open-collector interface

The following figures show how to connect the reader for ISO2 and Wiegand.

USEREQUIPMENT

HYPERXREADER

O1

O2

O3

O5

5 - 12 VDC

1K

0V

CLOCK

DATA

PRES_BADGE

Figure 10-10 : ISO2 connection to reader

VCC

12V

CTP

10n10K

33K

uP

Page 68: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 68/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

USEREQUIPMENT

HYPERXREADER

O1

O2

O5

1K

0V

DATA1

DATA0

5 - 12 VDC

Figure 10-11 : WIEGAND connection to reader

10.4 Outputs (JR3 – LMB only)

pin name description 1 VI1 Supply voltage for output 1 2 SIC1 Collector output 1 3 SIE1 Emitter output 1 4 VI2 Supply voltage for output 2 5 SIC2 Collector output 2 6 SIE2 Emitter output 2

10.5 Inputs (JR4 – LMB only)

pin name description 1 EI1 Signal for input 1 2 GND1 Reference for input 1 3 EI2 Signal for input 2 4 GND2 Reference for input 1

10.6 Relay (LPR and modular)

pin name 1 Make 2 Common 3 Break

This connection allows a signal to be switched using the on-board relay. When the relay is not energized, pins 2 and 3 are connected together, when it is, pins 1 and 2 are connected together.

The relay can switch currents of up to 1A and voltages up to 150VDC/125VAC.

Page 69: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 69/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

11 APPENDIX A : Algorithm for calculating the CRC16

set CRC16 = 0xFFFF

CRC16 ^ byte � CRC16

get byte

n = 0

shift right 1 bit CRC16

CRC16 ^ polynomial �

n = n + 1

finished all bytes ?

stop

carry

?

n = 8 ? no

no

yes

yes

start

yes

no

Page 70: Reader Interface Manual

REFERENCE DU DOCUMENT / DOCUMENT REFERENCE

Langue/ Language Numéro / Number Code Doc. / Doc. Code Indice / Revision Index Pages GB 13053 104 C 70/70

CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION.

12 APPENDIX B : Channel frequencies

Sorted by frequency Sorted by channel number Channel N° frequency (MHz) Channel N° frequency (MHz)

31 2446.25 1 2448.00 24 2446.50 2 2448.25 25 2446.75 3 2448.50 26 2447.00 4 2448.75 27 2447.25 5 2449.00 28 2447.50 6 2449.25 29 2447.75 7 2449.50 1 2448.00 8 2449.75 2 2448.25 9 2450.00 3 2448.50 10 2450.25 4 2448.75 11 2450.50 5 2449.00 12 2450.75 6 2449.25 13 2451.00 7 2449.50 14 2451.25 8 2449.75 15 2451.50 9 2450.00 16 2451.75 10 2450.25 17 2452.00 11 2450.50 18 2452.25 12 2450.75 19 2452.50 13 2451.00 20 2452.75 14 2451.25 21 2453.00 15 2451.50 22 2453.25 16 2451.75 23 2453.50 17 2452.00 24 2446.50 18 2452.25 25 2446.75 19 2452.50 26 2447.00 20 2452.75 27 2447.25 21 2453.00 28 2447.50 22 2453.25 29 2447.75 23 2453.50 30 2453.75 30 2453.75 31 2446.25

For the LPR, channel numbers go from 1 to 29, channel numbers 30 and 31 are not available.