2
1/2 TURN TO STOP Installation of Electronic Cover Plate ► 9/16 Open-end wrench (for Redtail) ► 1/2 Open-end wrench (for Roadside) Installation onto Gauge Head ► 7 / 16 Open End Wrench Calibration (Zero & Span) ► Connections to you PLC or a Fluke 780 (or Eq.) 24 VDC Loop Calibrator ► 1/8” Blade screwdriver This document contains the recommended basic procedures installing and calibrating the Hawkeye Industries Goshawk Level Transmitter for use on a Redtail or Roadside Gauge Head. For more comprehensive instructions, please refer to the Goshawk Operation and Trou- bleshooing Guide. Requirements The gauge board, indicator, float, and gauge head, shall be in place per their respective installation instructions prior to Goshawk installation. Tools Parts Required Goshawk Installation on Gauge Head TANK PREPARATION | GAUGE BOARD KIT INSTALLATION | FLOAT GUIDE KIT INSTALLATION | GAUGE HEAD INSTALLATION | GOSHAWK INSTALLATION Quick Start Installation Instructions Goshawk Level Transmitter QTY Part 1 Goshawk Level Transmitter 2 1/4-20 UNC x 3/4 Hex Cap screw (included) Installation on Redtail 1 Redtail Gauge Head with 1 Redtail Electronic Cover Plate installed Installation on Roadside 1 Roadside Gauge Head with: 1 Roadside Electronic Cover Plate installed 1 2 3 4 If the electronic cover plate is not already installed, remove the standard cover plate from the Indicator (Open) side of the gauge head, and replace with the appropriate Electronic Cover Plate for your gauge head. Turn the indicator cable spool IN THE EMPTYING DIRECTION (CLOCK- WISE) until the the indicator is in the empty position (top of gauge board). Immobilize the spool. (cover omitted for clarity) Goshawk Quick Installation Instructions, March 2014. Replaces May 2012 document 1 Turn the Transition Coupler on the Goshawk Transmitter IN THE EMPTY- ING DIRECTION (COUNTER-CLOCKWISE) until it stops. DO NOT OVER TURN, AS DAMAGE WILL OCCUR. Then turn the Transition Coupler on the Goshawk Transmitter IN THE FILLING DIRECTION (CLOCKWISE) one-half turn Aligning the tangs on the transmitter with the cover plate bolt holes and fasten with the 1/4 NC Hex Cap Screws. Ensure the transition coupler mates with the gauge head axle without binding by turning the reel a few times before tightly securing the transmitter to the cover plate. REDTAIL ROADSIDE REDTAIL ROADSIDE

Quick Start Installation Instructions Goshawk Level ... · Goshawk Quick Installation Instructions, March 2014. Replaces May 2012 document 1 Turn the Transition Coupler on the Goshawk

  • Upload
    others

  • View
    16

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Quick Start Installation Instructions Goshawk Level ... · Goshawk Quick Installation Instructions, March 2014. Replaces May 2012 document 1 Turn the Transition Coupler on the Goshawk

1/2 TURN

TO STOP

Installation of Electronic

Cover Plate

► 9/16 Open-end wrench

(for Redtail)

► 1/2 Open-end wrench

(for Roadside)

Installation onto Gauge Head

► 7 / 16 Open End Wrench

Calibration (Zero & Span)

► Connections to you PLC or a

Fluke 780 (or Eq.) 24 VDC

Loop Calibrator

► 1/8” Blade screwdriver

This document contains the recommended basic procedures installing and calibrating the Hawkeye Industries Goshawk Level Transmitter

for use on a Redtail or Roadside Gauge Head. For more comprehensive instructions, please refer to the Goshawk Operation and Trou-

bleshooing Guide.

RequirementsThe gauge board, indicator, float, and gauge head, shall be in

place per their respective installation instructions prior to Goshawk

installation.

Tools

Parts Required

Goshawk Installation on Gauge Head

TANK PREPARATION | GAUGE BOARD KIT INSTALLATION | FLOAT GUIDE KIT INSTALLATION | GAUGE HEAD INSTALLATION | GOSHAWK INSTALLATION

Quick Start Installation Instructions

Goshawk Level Transmitter

QTY Part

► 1 Goshawk Level Transmitter

► 2 1/4-20 UNC x 3/4 Hex Cap screw (included)

Installation on Redtail

► 1 Redtail Gauge Head with

► 1 Redtail Electronic Cover Plate installed

Installation on Roadside

► 1 Roadside Gauge Head with:

► 1 Roadside Electronic Cover Plate installed

1

2

3

4

If the electronic cover plate is not already installed, remove the standard

cover plate from the Indicator (Open) side of the gauge head, and replace

with the appropriate Electronic Cover Plate for your gauge head.

Turn the indicator cable spool IN THE EMPTYING DIRECTION (CLOCK-

WISE) until the the indicator is in the empty position (top of gauge board).

Immobilize the spool. (cover omitted for clarity)

Goshawk Quick Installation Instructions, March 2014. Replaces May 2012 document 1

Turn the Transition Coupler on the Goshawk Transmitter IN THE EMPTY-

ING DIRECTION (COUNTER-CLOCKWISE) until it stops. DO NOT OVER

TURN, AS DAMAGE WILL OCCUR. Then turn the Transition Coupler on

the Goshawk Transmitter IN THE FILLING DIRECTION (CLOCKWISE)

one-half turn

Aligning the tangs on the transmitter with the cover plate bolt holes and

fasten with the 1/4 NC Hex Cap Screws. Ensure the transition coupler

mates with the gauge head axle without binding by turning the reel a few

times before tightly securing the transmitter to the cover plate.

RE

DTA

IL

RO

AD

SID

E

RE

DTA

IL

RO

AD

SID

E

Page 2: Quick Start Installation Instructions Goshawk Level ... · Goshawk Quick Installation Instructions, March 2014. Replaces May 2012 document 1 Turn the Transition Coupler on the Goshawk

Hawkeye Industries Inc.2

Loop Power Connections

After removing the transmitter cover, the PCB will be visible.

Run the conductors from the conduit port into the transmitter body, and

connect the positive lead from your PLC or Process Meter to the (+) termi-

nal, and the negative lead to the (-).

A Ground or Shield termination (S) is also provided for convenience.

Remove the transmitter cover to expose the PCB and wiring connections.

6

5

REDTAIL SYSTEM ROADSIDE SYSTEM

GOSHAWK

Calibration

Power up the PLC or loop calibrator. Adjust the R20 (Zero) trimmer (high-

lighted) to achieve a 4 mA output. Turn the trimmer clockwise to increase

the output value, counterclockwise to decrease. If the zero does not in-

crease above 3.5 mA, this is indicative of a damaged potentiometer, see

Section 7.1 Operating and Troubleshooting Guide.

If not already in place, put the gauging system into the TANK EMPTY PO-

SITION, noting the direction of travel of the highlighted items. If the tank

is in-service, see Section 3.3.3 and 4.2 in the Operating and Trou-

bleshooting Guide.

7

REDTAIL SYSTEM ROADSIDE SYSTEM

GOSHAWK

Put the gauging system into the TANK FULL POSITION, noting the direc-

tion of travel of the highlighted items.

9

8

Adjust the R19 (Span) trimmer (highlighted) to achieve a 20 mA output.

Turn the trimmer clockwise to increase the output value, counterclockwise

to decrease. If the span remains below 20 mA, or remains above 20 mA,

this is indicative of problems with the span sensitivity. Refer to Section

4.1 in the Operating and Troubleshooting Guide.

Reinstall the cover, and the transmitter is ready for service.

Please refer to the Operations and Troubleshooting Guide for more de-

tailed notes on installation, calibration and non-standard configurations.

10

APPROVED CLASS 2 POWER SUPPLY ONLY