Pumps and Pumps and compressorscompressors

Page 2: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

Pumps and compressorsPumps and compressorsSub-chapters• 9.1. Positive-displacement

pumps• 9.2. Centrifugal pumps• 9.3. Positive-displacement

compressors• 9.4. Rotary compressors• 9.5. Compressor efficiency

Page 3: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

In Chapters 4, 5, and 6, we have written energy balance equations whichinvolve a dWa,o term (see Sec. 4.8 for a definition of dWa.o).

For steady-flow this term generally represents the action of a pump, fan, blower, compressor turbine, etc. This chapter discusses the fluid mechanics

of the devices which actually perform that dWa,o

Page 4: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

POSITIVE-DISPLACEMENT PUMPSPOSITIVE-DISPLACEMENT PUMPS

• Pumps work on liquid and compressors work on a gas.

• Most mechanical pumps are one of these:1. Positive-displacement2. Centrifugal3. Special designs with characteristics

intermediate between the two4. In addition, there are nonmechanical pumps

(i.e., electromagnetic, ion, diffusion,jet, etc.), which are not considered here.

Page 5: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• Positive-displacement (PD) pumps work by allowing a fluid to flow into enclosed cavity from a low-pressure source, trapping the fluid, and then forcing it out into a high-pressure receiver by decreasing the volume of the cavity.

• Examples are the fuel and oil pumps onmost automobiles, the pumps on most hydraulic systems, and the heartsmost animals.

• Figure 9.1 shows the cross-sectional view of a simple PD pump

Page 6: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors
Page 7: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

The operating cycle of such a pump is asfollows, starting with the piston at the top• The piston starts downward, creating a

slight vacuum in the cylinder.• The pressure of the fluid in the inlet line is

high enough relative to this vacuum to force open the left-hand valve, whose spring has been designed to let the valve open under this slight pressure difference.

• Fluid flows in during the entire downward movement of the piston.

Page 8: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• The piston reaches the bottom of its stroke and starts upward. This raises the pressure in the cylinder > the pressure in the inlet line, so the inlet valve is pulled shut by its spring.

• When the pressure in the cylinder > the pressure in the outlet line, the outlet valve is forced open.

• The piston pushes the fluid out into the outlet line.

• The piston starts downward again; the spring closes the outlet valve, because the pressure in the cylinder has fallen, and the cycle begins again

Page 9: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• Suppose that we test such a pump, using a pump test stand, as shown in Fig. 9.2.

• With the pump discharge pressure regulator (a control valve) we can regulate the discharge pressure and, using the bucket, scale, and clock, determine the flow rate corresponding to that pressure.

• For a given speed of the pump's motor, the results for various discharge pressures are shown in Fig 9.3.

Page 10: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors
Page 11: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors
Page 12: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• From Fig. 9.3 we see that PD pumps are practically constant-volumetric flow-rate devices (at a fixed motor speed) and that they can generate large pressures. The danger that these large pressures will break something is so severe that these pumps must always have some kind of safety valve to relieve the pressure if a line is accidentally blocked.

• For a perfect PD pump and an absolutely incompressible fluid, the volumetric flow rate equals the volume swept out per unit time by the piston,

Volumetric flow rate = piston area x piston travel x cycles/time (9.1)

Page 13: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• For an actual pump the flow rate will be slightly less because of various fluid leakages.

• If we write Bernoulli's equation (Eq. 5.7) from the inlet of this pump to the outlet and solve for the work input to the pump, we find

• (9.2)

• The 1st term on the right represents the "useful" work done by the pump: increasing the pressure, elevation, or velocity of the

• The 2nd represents the "useless" work done in heating either the fluid the surroundings.

2a,odW P V

gzdm 2

F

Page 14: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• The normal definition of pump efficiency is

(9.3)

• This gives in terms of a unit mass of fluid passing through the pump.

• It is often convenient to multiply the top and bottom of this equation by the mass flow rate , which makes the denominator exactly equal to the power supplied to the pump:

(9.4)

2

a,0

P / gz V / 2usefulworkPumpeff .,

totalwork dW / dm

2m. P / gz V / 2usefulwork

totalwork power supplied

Page 15: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

Example 9.1. A pump is pumping 50gal/min of water from a pressure of 30psia to a pressure of 100psia. The changes in elevation and velocity are negligible. The motor which drives the pump is supplying 2.80 hp. What is the efficiency of the pump?

• The mass flow rate through the pump is

50gal lbm lbm kgm .8.33 417 189

min gal min min

Page 16: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• so, from Eq. 9.4,

• From this calculation we see that the numerator in Eq. 9.4 has the dimension of horsepower. This numerator is often referred to as the hydraulic horsepower of the pump.

2 2 2

3 2

lbm 100lbf / in 30lbf / in 144in hp.min417 . . .

min 62.3lbm / ft ft 33,000ft.lbf0.73

2.80hp

Page 17: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

becomes equal to the hydraulic horsepower divided by the total horsepower supplied to the pump.

• For large PD pumps, can be as high as 0.90; for small pumps it is less.

• One may show (Prob. 9.4) that for the pump in this example the energy which was converted to friction heating and thereby heated the fluid would cause a negligible temperature rise. The same is not true of gas compressors, as discussed in Sec. 9.3.

Page 18: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• If we connect our PD pump to a sump, as shown in Fig. 9.4, and start the motor, what will happen? A PD pump is generally operable as a vacuum pump. Therefore, the pump will create a vacuum in the inlet line. This will make the fluid rise in the inlet line.

• If we write the head form of Bernoulli's equation, Eq. 5.11, between the free surface of the fluid (point 1) and the inside of the pump cylinder, there is no pump work over this section; so

Page 19: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• . (9.5)

• If, as shown in Fig. 9.4, the fluid tank is open to atmosphere, then P1 = Patm. The maximum value of h possible corresponds to P2 = 0. If there is no friction and the velocity at 2 is negligible, then

• . (9.6)

• For water under normal Patm and Troom, hmax 34 ft = 10 m. This height is called the suction lift.

21 2 2

2 1

P P Vz z h

g 2g g

F

atmmax

Ph

g

Page 20: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors
Page 21: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

The actual suction lift obtainable with a PDpump < that shown Eq. 9.6 because• There is always some line friction, some

friction effect through the pump inlet valve, and some inlet velocity.

• The pressure on the liquid cannot be reduced to zero with causing the liquid to boil. All liquids have some finite vapor pressure. For water at room temperature, it is about 0.3 psia or 0.02 atm. If the pressure < 0.02 atm, the liquid will boil.

Page 22: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

Example 9.2. • We wish to pump 200 gal/ min of water at

150oF from a sump. We have a PD pump which can reduce absolute pressure in its cylinder to 1 psia. We have an F/g (for the pipe only) of 4 ft. The friction effect in the valve may be considered the same as that of a sudden expansion (see Sec.5.5) with the inlet velocity equal to the fluid flow velocity through the valve, which is 10 ft/s. The atmospheric pressure at this location >= 14.5 psia.

• What is the maximum elevation above the water level in the sump at which we can place the pump inlet?

Page 23: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

Answer• The lowest pressure we can allow in the

cylinder P is 3.72 psia, the vapor pressure of water at 150oF. If the pressure < 3.72 psia, the water would boil, interrupting the flow. The density of water at 150oF = 61.3 lbm/ft3.

• Thus

• =19.8 ft = 6.04 m

22 2 2

max 3 2 2 2 2

10ft / s14.5lbf / in 3.7lbf / in 144in lbm.fth . .32.2 4ft

61.3lbm / ft x32.2ft / sc ft lbf .s 2x32.2ft / s

Page 24: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

CENTRIFUGAL PUMPSCENTRIFUGAL PUMPS• A centrifugal pump raises the pressure of

a liquid by giving it a high kinetic energy and then converting that kinetic energy to injection work. The water pump on most automobiles is a typical centrifugal pump.

• As shown in Fig. 9.5. it consists of an impeller (i.e., a wheel with blades) and some form of housing with a central inlet and a peripheral outlet.

• The fluid flows in the central inlet into the "eye" of the impeller, is spun outward by the rotating impeller, and flows out through the peripheral outlet.

Page 25: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors
Page 26: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• To analyze such a pump on a very simplified basis, use Bernoulli's equation (Eq. 5.7) between the inlet pipe (point 1) and the outer tips of the impeller blades (point 2)

• The elevation change and V1 negligible. We assume that the friction losses also are negligible.

• Although P2 > P1, this term is small compared with the change in kinetic energy

• (9.7) 2

a,o2dWV

approximately2 dm

Page 27: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• This equation indicates that the pump work, which enters through the rotating shaft, principally increases the kinetic energy of the fluid as it flows across the impeller from the eye to the tips of the blades.

• The tangential velocity at any point istangential velocity = radius x angularvelocity (9.8)

• The angular velocity (2 rpm) is constant for the whole impeller, but the radius from 0 at the eye to a significant value at the tip of the blades. Max tangential vel. = V2

Page 28: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• Use Bernoulli's equation from the tip of the blades (point 2) to the outlet pipe (point 3).

• The change in elevation is negligible, and friction is neglected. No work on the fluid between points 2 and 3. V3 negligible. Thus

(9.9)

• This equation indicates that the section of the pump from the tip of the rotor blades to the outlet pipe converts the kinetic energy of the fluid to increased pressure

2

3 2 2P P Vapproximately

2

Page 29: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• Thus, the centrifugal pump may be considered a two-stage device:1. The impeller increases the kinetic energy of the fluid at practically constant pressure.2. The diffuser converts this kinetic energy to increased pressure.

• Equations 9.7 and 9.9 suggest that for a given pump size and speed, P/(g) should be constant.

• Figure 9.6 shows the results of such a test for a large, high-efficiency pump. As predicted by the simple model, for low flow rates, P/(g) ≠ f(flowrate)

Page 30: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors
Page 31: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

Example 9.3. A typical centrifugal pump runs at 1800rpm (mainly because of the convenient availability of 1800rpm electric motors). If the fluid being pumped is water, what is the maximum pressure difference across the pump for impeller diameters of 1, 3, and 10 in?

• Using Eq 9.9

• For impeller 1 in

2 221

2 1

rV DP P 2 rpm

2 2 2 2

23 2 2 2

2 1 2 2

62.3lbm / ft ft 1800 min lbf .s ftP P . . . .

2 12 min 3600s 32.2 lbm.ft 144in

Page 32: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• = 0.41 psi = 2.86 kPa• For 3-in dia impeller

• For 10-in dia impeller

2

2 1

3inP P 0.41psi 3.7 psi

1in

2

2 1

10inP P 0.41psi 41psi

1in

Page 33: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• This example illustrates the fact that centrifugal pumps supply small +P with small impellers and high +P with large impellers.

• When a large pressure rise is required, we can obtain it by hooking several centrifugal pumps in series (head to tail).

• The normal practice is to put several impellers on a common shaft and to design a casing so that the outlet from one impeller is fed through a diffuser directly to the inlet of the next impeller. This is particularly true of deep-well centrifugal irrigation pump.

Page 34: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

The performance curve of a real pump,shown on Fig. 9.6, indicates some thelimitations of our simple model:• As the flow rate is large, the +P

decreases, which is not predicted by the model.

• The model would indicate = 100 % for all flow rates, whereas the actual varies over a wide range, peaking near 90 % at the design operating range.

Page 35: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• As in Example 9.3, we let the pump turn at 1800 rpm and have an impeller of 10-in diameter. If the pump is full of water, the pump has a P of +42 psi; so there is no problem with the suction lift.

• When we start the pump, the fluid around the impeller is air. Therefore, from Eq. 9.9 we find +P (V1 is kept constant due to tip design) is

2 3air1

2 1 3w

V 0.75lbm / ftP P 41psi. 41psi. 0.05psi

2 62.3lbm / ft

Page 36: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• If this pump is discharging into the atm and the sump is open to atm, then the pump, when full of air, can lift the water only a height of

• To get a centrifugal pump going, one must replace the air in the system with liquid. This is called priming.

• Numerous schemes for performing this function are available

2 2

3 2 2 2

P 0.05lbf / in 32.2 lbm.ft 144inh . . 0.1ft 0.03m

g 62.3lbm / ft x32.2ft / s lbf .s ft

Page 37: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• Centrifugal pumps are often used to pump boiling liquids, e.g., at the bottom of many distillation columns.

• Between inlet pipe (point 1) and the point on the blades of impeller where the pump starts to increase pressure (point 1a)

• . (9.10)

• P1a falls and boiling may occur. V1a, P1a• In this case the pump must be located far

enough below the boiling surface so that the +P due to gravity from the boiling surface to the pump eye > -P in the pump eye.

21a

1a 1

VP P

2

Page 38: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• This elevation is shown as h in Fig. 9.7. This distance required below the boiling surface is called the net positive suction head (NPSH).

Page 39: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

The pressure in Fig. 9.8 is the pressure measured at the pump inlet. If there is significant frictional -P between the vessel and the pump, then h in Fig. 9.7 must be increased to overcome this additional -P.

Page 40: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

Characteristic Positive displacement

Centrifugal

Normal flow rate Low High

Normal P/stage High Low

Variable held constant

Flowrate Pressure rise

Self-priming Yes No

Number of moving parts

Many Few

Outlet stream Pulsing Steady

Work well on high-viscosity fluid

Yes No

Page 41: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

POSITIVE-DISPLACEMENT POSITIVE-DISPLACEMENT COMPRESSORSCOMPRESSORS

• A compressor has Poutlet/Pinlet >> 1.• If P is small, the device is called a blower

or fan. Blowers and fans work practically the way as centrifugal pumps, and their behavior can be readily predicted by equations developed for centrifugal pumps.

• To compress a gas to a final (absolute) pressure > 1.1 times its inlet pressure requires a compressor, and the change in density of the gas must be taken into account.

Page 42: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• A PD compressor has the same general form as a PD pump. The operating sequence is the same as that described in Sec. 9.1. The differences are in the size and speed of the various parts (recall Eq 9.9).

• The pressure-volume history of the gas in the cylinder of such a compressor is shown

in Fig. 9-9.Cycle: ABCD

Page 43: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• The work of any single-piston process is given by

• . (9.11)• The work done by the compressor on the

gas is the gross work done on the gas (under curve CDA) minus the work done by the gas on the piston as the flowed in (area under curve BC); thus, the net work is the area enclosed by curve ABCD. This is the work done on the gas.

• Compressors are often used to compress gases which can be reasonably well represented by the perfect-gas law PV= nRT.

W Fdx PAdx PdV

Page 44: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• If a compressor works slowly enough and has good cooling facilities, then the gas in the cylinder will be at practically a constant temp throughout the entire compression process. Then we may substitute nRT/P for V in Eq. 9.12 and integrate:

• .

(9.13)

2 2

1 1

P P

2

1P P

PdPW VdP nRT nRT ln isothermal

P P

Page 45: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• However, in most compressors the piston moves too rapidly for the gas to be cooled much by the cylinder walls.

• If so, the gas will undergo what is practically a reversible, adiabatic process, i.e., an isentropic process.

• .PVk = P1V1k = constant [adiabatic] (9.14)

• Inserting this in Eq. 9.11• .• .

(9.15)

2

1

k 1 / kP

1 2

1P

nRTk PW VdP 1 adiabatic

k 1 P

Page 46: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

Example 9.4. A 100 % efficient compressor is required to compress from 1 to 3 atm. The inlet temperature is 68oF. Calculate the work pound-mole for an isothermal compressor and an adiabatic compressor.

• For an isothermal compressor,

• For an adiabatic compressor

o2o

1

PW Btu Btu kJRT ln 1.987 .528 R.ln 3 1153 2.68

n P lbmol. R lbmol mol

o 0.4 /1.4o

W Btu 1.4 Btu kJ1.987 .528 R. . 3 1 1355 3.15

n lbmol. R 0.4 lbmol mol

Page 47: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• Equations 9.13 and 9.15 in Example 9.4 indicate that the required work for an adiabatic compressor is always > that for an isothermal compressor with the same inlet and outlet pressures.

• Therefore, it is advantageous to try to make real compressors as nearly isothermal as possible.

• One way to do this is to cool the cylinders of the compressor, and this is generally done with cooling jackets or cooling fins on compressors.

• Another way is by staging and intercooling; see Example 9.5

Page 48: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

Example 9.5. Air is to be compressed from 1 to 10 atm. The inlet temp is 68oF. What is the work per mole for (a) an isothermal compressor, (b) an adiabatic compressor, and (c) a two-stage adiabatic compressor in which the gas is compressed adiabatically to 3 atm, then cooled to 68oF, and then compressed from 3 to 10 atm?

• For an isothermal compressor,

oo

W Btu Btu kJ1.987 .528 R.ln10 2416 5.62

n lbmol. R lbmol mol

Page 49: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• For an adiabatic compressor,

• For a two-stage adiabatic compressor,

=2862 Btu/lbmol=6.66 kJ/mol.

o 0.4 /1.4o

W Btu 1.4 Btu kJ1.987 .528 R. . 10 1 3418 7.96

n lbmol. R 0.4 lbmol mol

0.4 /1.4o 0.4 /1.4

o

W Btu 1.4 101.987 .528 R. . 3 1

n lbmol. R 0.4 3

Page 50: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• This example illustrates the advantage of staging and intercooling.

• With an infinite number of stages with intercooling, an adiabatic compressor would have the same performance as an isothermal compressor (Prob. 9.21).

• Thus, the behavior of an isothermal compressor represents the best performance obtainable by staging.

• The optimum number of stages is found by an economic balance between the extra cost of each additional stage and the improved performance as the number of stages is increased.

• Large PD compressors typically have stage Pout/Pin of 3-5 and of 75- 85% (Sec. 9.5)

Page 51: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

ROTARY COMPRESSORSROTARY COMPRESSORS• The PD compressor has been a common

industrial tool. But, it is a complicated, heavy, expensive, low-flow-rate device.

• The need to supercharge aircraft reciprocating engines and the development of turbojet gas-turbine engines demanded the development of lightweight, efficient, low-cost, high-flow-rate compressors.

• The resulting compressors, which were developed for aircraft service, are now being applied industrially in high-capacity applications, for example, in ammonia plants.

Page 52: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• The two types of compressor developed for aircraft engines are centrifugal and axial-flow.

• The centrifugal compressor is a centrifugal pump with very high-speed (for example, 20,000rpm) and large-diameter rotor. To give high-pressure ratios, centrifugal compressors are normally staged with intercooling; the pressure rise per stage is small.

• Axial-flow compressors pass the gas between numerous rows of blades arranged in an annulus (Fig. 9.10). The gas is successively accelerated by a moving row of rotor blades and then slowed by a stator blade which converts the kinetic energy imparted by the rotor blades to pressure

Page 53: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors
Page 54: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• The advantages of the axial-flow compressor over centrifugal compressors are the small cross-sectional area perpendicular to gas flow, which makes it easy to build into a streamlined airplane, and the lower velocities, which lead to lower friction losses and slightly higher .

• Centrifugal and axial-flow compressors generally handle very large volume of gases in small equipment, so the heat transfer from the gases is negligible.

• Their performance is well described by the equations for adiabatic compressors (see Eq. 9.15).

Page 55: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• Chap. 5 showed that for any steady-flow compressor in which changes in potential and kinetic energy are negligible

• . (4.40) a,oin out

dW dQh h

dm dm

Page 56: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

COMPRESSOR EFFICIENCIESCOMPRESSOR EFFICIENCIES• .

(9.17)• In the case of an adiabatic compressor, the

best possible device is a reversible, adiabatic compressor for which the inlet and outlet entropies are the same. It is commonly called an isentropic compressor.

(9.18)

work required for best possibledevicedoing job

work actually required bydevice

compressor

work of isentropiccompressor

work of realcompressor

Page 57: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• Consider the steady-flow, adiabatic compressor shown in Fig. 9.11. The balance for this process (taking the compressor as the system and assuming that changes in kinetic and potential energies are negligible):

• . (9.19)

• the real compressor has a higher outlet entropy, temperature, and enthalpy than the outlet stream from a reversible compressor would (2s in Fig. 9.11).

in out 1 2

dWh h h h

dm

Page 58: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors
Page 59: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• Comparing the real compressor with a reversible one having the same outlet

pressure. (9.20)isentropic 2s 1

comp or pumpreal 2 1

W h h

W h h

Page 60: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

Example 9.6. An adiabatic compressor is compressing air from 20oC and 1.4atm. The airflow rate is 100kg/h, and the power required to drive the compressor is 5.3 kW. What are the efficiency of the compressor and the temperature of the outlet air? What would the outlet air temperature be if the compressor were 100 percent efficient?

• Air may be assumed to be a perfect gas with Cp = 29.3 J/(mol.K) and k = 1.40. The work of an isentropic compressor doing the same job is given by Eq. 9.15:

Page 61: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• .

• .

• .

• .

• .

0.4 /1.4a.odW 293.15K 813J 1.4 J. . . 4 1 143

dm 29g /mol mol.K 0.4 g

a,o 5dW g J W hPo m 10 .143 . . 3.97kW

dm h g J.s 3600s

3.97kW0.75

5.3kW

a,oreal

p p

dW / dmhT

C C

real

5.3kW / 100kg / h 3600s JT . . 189K

h W.s29.3J / mol.K . mol / 29g

Page 62: Pumps and compressors. Sub-chapters 9.1. Positive-displacement pumps 9.2. Centrifugal pumps 9.3. Positive-displacement compressors 9.4. Rotary compressors

• .

• For an isentropic compressor,• .

• .

• This example illustrates the fact that the effect of the compressor inefficiency is to raise the outlet temperature of the compressor

0 o ooutT 20 C 189K 209 C 408 F

a,oideal

p p

dWhT

C C

ideal

3.97kW / 100kg / h 3600s JT . . 142K

h W.s29.3J / mol.K . mol / 29g