Process Analytics Shows Its Colors.
Stratos® Pro
Process analyzers for pH, ORP, conductivity, or oxygen with unique color-guided interface. For analog and digital sensors.
2
Stratos® Pro Seriesfor pH, ORP, Conductivity, or Dissolved Oxygen
Liquid analysis can now be seen in a completely new light...
Stratos® Pro
Ground-breaking process analyzers for the
measurement of pH, ORP, conductivity or
dissolved oxygen.
Stratos® Pro High-contrast, easily legible widescreen display.
Unique interface prompts user with functional
colored backlighting.
Stratos® Pro For connection of all common analog and digital sensors
(including contactless) with significantly enhanced
predictive diagnostics.
Stratos® Pro Thanks to innovative enclosure technology, the analyzers
are ideally suited for use in virtually any environment.
Appropriate for hazardous installations.
For more information on Stratos® Pro, go to www.knick.de/stratospro
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
White: Normal measuring mode
Turquoise: Diagnostics
Red blinking: Alarm, errors
Magenta: Maintenance request
4
Operation.
The unique color-guided
backlit display guarantees
maximum operating safety
for 4- and 2-wire devices.
The display of the Stratos® Pro devices is backlit white in normal operation. Alarm, maintenance request, and other operating states are indicated by colored displays.
Stratos® Pro SeriesFor pH, ORP, Conductivity, or Dissolved Oxygen
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Orange: HOLD mode
Green: Info texts
5
Stratos® ProNew operating concept.
The Stratos® Pro series realizes a completely new and especially user-friendly operating concept in modern analyzers. Studies have shown that operator errors more frequently lead to downtime than hardware defects or malfunctions. A user-friendly design and intui-tive operation has been given the highest priority in the new series.
Stratos® Pro Setting the standard.
The unique backlit display of the Stratos® Pro changes between six different colors to clearly signal operating states. The normal measuring mode is white. Information text appears on a green screen and the diagnostic menu appears on turquoise. The orange HOLD mode is quickly visible as is the magenta screen which indicates maintenance requests and sensor wear.
The alarm status has a particularly noticeable red display color and is also signaled by fl ashing display values. Unreliable entries or false passcodes cause the entire display to blink red so that operating errors are noticeably reduced.
Stratos® ProClarity of display.
A pin sharp and high-contrast LC display provides optimum legibility, even in the most difficult lighting conditions. Instead of pixilated elements which are sometimes difficult to identify, the display utilizes high-resolution, self-explanatory icons. Longer text displays are scrolled horizontally in a large, clearly legible font: a scrolling ticker line is more easily and reliably comprehended than text in jumping lines.
6
Stratos® Pro Seriesfor pH, ORP, Conductivity, or Dissolved Oxygen
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Memosens® is a new open standard of a smart,
contactless sensor connection system.
A Memosens® seal of approval guarantees quality
and compatibility.
This allows the user to choose from different sensor
manufacturers.
The New Memosens®.
The new Memosens® System is characterized by a patented quick connector that enables easy opening/closing without twisting the cable.
The key element of the system is the signal processing carried out in the sensor cap using inductive, contactless data transfer and power supply.
This allows reliable measurement completely insensitive to ambient conditions such as– humidity– corrosion– salt bridges – bad contacts – poor galvanic isolation – cables that are unsuitable or
too long
The system can even be connected under water. The connector is metal-free. Perfect galvanic isolation enables disturbance-free data transfer. Connection of a solution ground or equipotential bonding (EB) is not required.
7
Stratos® ProThe complete range.
Stratos® Pro facilitates the opera-tion of almost all standard sensors available on the global market, thanks to its innovative wiring technology in the 2- and 4-wire designs. The Stratos® Pro was designed to provide the greatest possible flexibility for the user. Even under the harshest of ambient conditions, the devices can be used in process applica-tions of all types to collect mea-sured values for pH, ORP, conduc-tivity (conductive and inductive), or oxygen.
Memosens® provides added value.Memosens® allows using precali-brated sensors so that costly on-site handling time is reduced and plant availability increases.
Predictive diagnostics combined with improved asset management enable innovative maintenance strategies.
Stratos® Pro For all high-quality sensors
pH measurement:
• For analog, digital and/or contactless pH sensors
• For combination electrodes as well as separate glass and reference electrodes
• For a wide selection of temperature sensors (Pt 100, Pt 1000, NTC 30 kohm, NTC 8.55 kohm or Balco 3 kohm)
• For all standard ORP metallic electrodes
• For all ISFET sensors
Conductivity, conductive (Cond):
• For all available 2- and 4-electrode sensors and/or contactless conductivity sensors
• Cell constant selectable from 0.005 to 20 cm–!
• Selectable temperature sensors Pt 100, Pt 1000, NTC 30 kohm, NTC 8.55 kohm
Conductivity, inductive (CondI):
• For a variety of conventional European and US sensors
• For Pt 100, Pt 1000, NTC 100 kOhm temperature sensors
Dissolved oxygen (Oxy):
• For commercially available, amperometric sensors with or without polarization voltage and/or contacless oxygen sensors
• For NTC 22 kohm, NTC 30 kohm temperature sensors
4-Wire Devices 2-Wire Devices
Safe area … Zone 2 Safe area … Zone 1
pH measurement Stratos® Pro A401N-pH
Stratos® Pro A401B-pH
Stratos® Pro A201N-pH
Stratos® Pro A201X-pH
Conductive conductiv-ity measurement
Stratos® Pro A401N-Cond
Stratos® Pro A401B-Cond
Stratos® Pro A201N-Cond
Stratos® Pro A201X-Cond
Inductive conductivity measurement
Stratos® Pro A401N-CondI
Stratos® Pro A401B-CondI
Stratos® Pro A201N-CondI
Stratos® Pro A201X-CondI
Dissolved oxygen measurement
Stratos® Pro A401N-Oxy
Stratos® Pro A401B-Oxy
Stratos® Pro A201N-Oxy
Stratos® Pro A201X-Oxy
pH measurement, Memosens®
Stratos® Pro A401N-MSPH
Stratos® Pro A401B-MSPH
Stratos® Pro A201N-MSPH
Stratos® Pro A201X-MSPH
Conductive conductiv-ity meas., Memosens®
Stratos® Pro A401N-MSCOND
Stratos® Pro A401B-MSCOND
Stratos® Pro A201N-MSCOND
Stratos® Pro A201X-MSCOND
DO measurement, Memosens®
Stratos® Pro A401N-MSOXY
Stratos® Pro A401B-MSOXY
Stratos® Pro A201N-MSOXY
Stratos® Pro A201X-MSOXY
MEMOSENS
MEMO SENS
Indu Con
in p
roce
ss
to the lab
calib
ration/adjustment/data transmission
to fi
eld lo
cation
8
Stratos® Pro SeriesFor pH, ORP, Conductivity, or Dissolved Oxygen
Isol
atio
n am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
met
ers
Labo
rato
ry m
eter
s
Sens
ors
Fitt
ings
Robustness.
All the electronics in a Stratos® Pro are encapsulated in the door module of the device.
New industry design to be used for applications
even under the harshest of ambient conditions:
Stratos® Pro. Fully encapsulated and protected
in shatter-proof and corrosion-resistant plastic
enclosure with outdoor approval rating.
Stratos® Pro Tough.
The reinforced and UV-resistant plastic enclosure of the Stratos® Pro supports the product func-tionality. There are neither prominent control elements nor those with a high mechanical load to be found on the practical, smooth, dirt-proof design. Injection molded, directly sealed keys are made from high-quality EPDM so that it is no longer necessary to stick films, which had to perform a sealing func-tion, onto the front of the device.The high IP 67 protection rating is retained under all conditions – reliable and safe operation is guaranteed in the range from –20 °C to +65 °C, even for oper-ation in hazardous locations.
Stratos® ProAll-round resilience.
The display window of the Stratos® Pro is connected directly to the plastic enclosure during the innovative molding process. It is made from reinforced safety glass, is scratch-resistant and UV-resistant. All the device's electron-ics are completely encapsulated in the door module: there are no exposed PCBs. The large rear unit can be mounted separately. All electrical connections are made by means of plug-in terminals in the door unit, so that if the door module is replaced, the complete cabling can be retained in the rear unit.
9
Stratos® ProSimple installation.
• Wall, post/pipe, or panel mounting
• All parts are easily accessible
• Large terminal compartment
• Rear unit can be pre-assembled
• Also suitable for rigid metallic conduits
• Replaceable plug-in terminals
• Replacement of the electronics without new cabling
10
Functionality.
Stratos® Pro 4-wire devices
Stratos® Pro 2-wire devices
From the wireless service interface to the complete HART
communication system, the Stratos® Pro series offers a wide
range of reliable functions for 4- and 2-wire devices.
The devices can be used in multidrop mode and are certified
for the handheld and asset management systems of the
leading manufacturers.
Unrivalled circuit technology ensures low self-heating and
an extremely long service life.
The 4-wire models from Stratos® Pro are equipped with the VariPower® broad-range power supply unit. This facilitates the use of the same device model for power supplies of 20 to 253 V AC/DC. Reliable operation is thereby guaranteed worldwide, even with fluctuating qualities of power supplies.
A number of outstanding techno-logical properties make the Stratos® Pro series the new benchmark for 2-wire analyzers. Colored screen backlighting has been realized for the first time in this device class, with the lowest possible electrical power. In contrast to all 2-wire devices previously available on the world market, two digital inputs are available as well as an analog input plus a second output for another measured value.
Globally ready.
• VariPower® power supply unit 20 ... 253 V AC/DC
• 2 x RS 485 for 2-channel operation with contactless sensors
• 2-channel mixed operation for analog sensors and contactless sensors
• 4 relay contacts for alarm, limit values, maintenance request
• PID controller
• The new benchmark for 2-wire devices
• Full functionality with 2-wire supply
• –20 °C to +65 °C permitted also for hazardous-area applications
• RS 485 for operating contactless sensors
The new benchmark.
Stratos® Pro SeriesFor pH, ORP, Conductivity, or Dissolved Oxygen
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Stratos® Pro
The Facts• Extremely robust, UV-resistant
IP 67 molded enclosure
• High-contrast widescreen display with color-guided backlighting
• Protective pane made of safety glass
• Intuitive operation with easy-to-understand icons and continuously running plain-text ticker line
• Logbook (200 entries)
• HART communication
• Wireless service interface (not necessary to open the enclosure)
• Two current outputs
• Two parameter sets
• Two digital inputs– external HOLD release– external parameter set selection
• One analog input (4 – 20 mA) e.g. for external pressure compensation
• Automatic sensor identification
• Sensor diagnostic with wear indication, remaining lifetime, CIP/SIP counter, and adaptive calibration timer
• Operation in hazardous areas (explosion-protected for gas and dust):4-wire: Zone 2 (FM, CSA Class I, Div. 2); 2-wire: Zone 1 (FM, CSA Class I, Div. 1)
• Wall, post/pipe, or panel mounting
3-year warranty
11
TP-2
12.0
00-E
0808
500
0
Subj
ect
to c
hang
e
Knick Elektronische Messgeräte GmbH & Co. KGBeuckestraße 22, D-14163 Berlin, Germany
Phone: +49 (0)30 - 801 91 - 0
Fax: +49 (0)30 - 801 91 - 200
www.knick.de
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings