48
Press F5 to view click arrows for next page Av-Gad Systems Ltd .

Press F5 to view click arrows for next page Av-Gad Systems Ltd

Embed Size (px)

Citation preview

Page 1: Press F5 to view click arrows for next page Av-Gad Systems Ltd

Press F5 to viewclick arrows for next page

Av-Gad Systems Ltd.

Page 2: Press F5 to view click arrows for next page Av-Gad Systems Ltd

Av-Gad Systems Ltd.

Short Alarm SystemsTechnical Seminar

Year 2013

Page 3: Press F5 to view click arrows for next page Av-Gad Systems Ltd

Introduction

This technical seminar will help you to get familiar with Av-Gad control panels and other products by offering technical data, tips and support; and also to tell you a little bit about our company.

Av-Gad Systems Ltd., is a private owned company, located in Tel-Aviv, Israel.

Our products line is advanced electronic security systems, for residential, commercial and military applications.

Page 4: Press F5 to view click arrows for next page Av-Gad Systems Ltd

Company profile

AV-GAD, established in 1980, is Israel's recognized leader in the design, development, manufacture and marketing of standard and customized Alarm Control Panels and accessories for industrial, institutional, and residential security applications. We hold an ISO-9001-2000 certification, approved by Lloyd’s, UK.

AV-GAD currently exports to countries on four continents, and controls a sizable share of the domestic market as well.

AV-GAD products are Auto Computer Tested under extreme environmental conditions and adhere to stringent Quality Control standards to guarantee total reliability. RFI suspension circuitry and superior protection against Voltage Surges ensure immunity to electrically "Noisy" environments.

Page 5: Press F5 to view click arrows for next page Av-Gad Systems Ltd

CONTACT US

Address:Av-Gad Systems Ltd.84, Ben-Zvi RoadPanorama House 4th floorTel-Aviv 68 104, Israel

Mail Address: Av-Gad Systems Ltd.P.O.B. 49080 Tel-Aviv 61 490, Israel

Communication:Telephone: +972-3 681 67 67International Fax: +972-3-683 55 05Domestic Fax: 03-681 55 51E-Mail: [email protected]

WEB:WEB: www.av-gad.com

Page 6: Press F5 to view click arrows for next page Av-Gad Systems Ltd

Main Products Line

EasyLoader Computerized Control Panels (4-32 zones), with the latest software and features; remote maintenance, reports to all central stations. Meet European marks; CE & CTR-21. Australian standards AUSTEL and other international standards

EasyKey remote keypads, telephone communicators and dialers

EasyRemote RF crystal controlled remote sets for Panic, arming and wireless remote activating devices

Freeko Wireless systems solution Eye-Spy II the most attractive PIR sensor at three

types Easy-Talk Voice module, high technology chip keeps

your message even when power is off. Bella your durable outdoor siren for all application AVG and Gismo lines for the latest GSM solutions

Page 7: Press F5 to view click arrows for next page Av-Gad Systems Ltd

Product sample

AV-707 LCD Keypad

Have you seen the news?Metal finished AV-707 and AV-702

Keypads, for elegant look .

Page 8: Press F5 to view click arrows for next page Av-Gad Systems Ltd

Technology

Av-Gad focuses exclusively on providing the newest technology and the latest security innovations to every one on four continents, through innovative and advanced technologies for a secure and safe environment.

Av-Gad offers to the users the best security

systems, smartly programmed as well as nicely designed.

Av-Gad production is based on the latest SMD (Surface Mount Devices) mixed with Feed Through technologies for highest reliability and performance

Page 9: Press F5 to view click arrows for next page Av-Gad Systems Ltd

Approvals & Certifications

Av-Gad approvals policy is based on customizing the product and getting country approvals according to markets demands. Av-Gad runs under ISO-9002 starting year 1995.

Approvals:

CE – Quality mark for electrical devices sold in Europe. Tested and approved by NEMCO International Laboratories.C-Tick – The Australian approved electric devices.CTR-21 – The standard for devices connected to the phone lines in Europe. Approved by NEMCO.AUSTEL - The standard for devices connected to the phone lines in Australia. Swedish Standards – Very high standard for alarm panels sold in Sweden and part of Scandinavian markets.Others: China, Slovakia, Finland.

Page 10: Press F5 to view click arrows for next page Av-Gad Systems Ltd

MANUFACTURING

Av-Gad products are manufactured at three main sites in Israel:

  Samples and prototypes production

department: Tel-Aviv

SMD and large volume order department: Yavne

Assembly and transformers department: Rishon Letzion

Page 11: Press F5 to view click arrows for next page Av-Gad Systems Ltd

PERSONNEL

Av-Gad various technical departments comprise 30 Engineers, Technicians and Quality Control specialists, each with at least 10 years of experience in their respective fields.

Our management, marketing and sales divisions comprise five handpicked and highly motivated people.

Page 12: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL SEMINAR

Control Panels

Tips for startingRead the manual in details

If you are using a PRO or Dublo panel read carefully the manual supplied with your LCD keypad. LCD and LED keypads cannot operate in the same system

To start with: Hook up the keypad, connect all zones to –V, power-up by applying AC only (battery current is unlimited and can damage the panel).

In case the keypad displays ‘garbage’ verify the minus (-V) wire connection

Arm and disarm the system, when the Status LED light (not blinking), enter your master code; 1234

Page 13: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL SEMINAR

Control Panels II

Tips for starting (cont.)

Try the hold-down functions. Hold each key for approximately 2 seconds; follow the confirmation letters in keypad’s display

Set the system time by holding-down key ‘1’ then ‘0’, enter the time in 24 hours format, this will stop the blinking ‘h’

The default programming is set for 12V siren; in case the siren is plain speaker horn, you have to change the programming to speaker mode

Page 14: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

Tips for starting II

For Australia & UK: To get strobe as per approvals, connect the siren’s strobe light to the SLO output (requires programming). The SLO supplies –V during alarm, resets only after disarming

Make sure you are using the Earth terminal for Grounding; it’s not a minus (-V) terminal

Typing six erroneous codes will lock the keypad keys for 30 seconds, don’t change code for starting

Page 15: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

Alarm control panel locationAlways install the control panel box in a hard-to-access location. Far away from electrical noise generators, transmitters, cellular phones and heat sources.

A continuously powered (non-switched) AC power source, compatible with any step‑downtransformer. Make sure the mains (110 or 220V) are fused.

Cold water pipe Ground, ideally no farther than 3 meters (10 feet) from the panel. Use 16 AWG(0.5 mm2) wires.

Telephone Line socket.

Page 16: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

General Wiring Tips

Do not run wire zones alongside telephone wires, high voltage wires, or transmitting antennae.Separate keypad wires, don't run in same cable with other devices (telephone, PIR's etc.)

Telephone wires generate great noise and spikes, try to run the telephone wires separately.

Maximum zone wiring length is 200 meters when using 0.5-mm2 (gauge 22 wire) wires.

Page 17: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

Zone Wiring

Series 2000 & 3000 allows three ways of zone wiring:

Non EOL resistor loop EOL resistor loop EOL for double zone loop

The EOL mode protects the zone lines against tampering. EOL mode is safer and prevents EMI and RFI interference.Important! Confusing point!Enter ‘0’ in address 029 to enable all zones as EOL.

Page 18: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

Double-Pole Mode

When using sensors with two separate switches or relay contacts; one for Alarm relay and one for Tamper switch. Each contact is connected to a different E.O.L. resistor.

  Alarm contacts connected in series with a 2.2K resistor; tamper contacts with a 4.7K resistor. Both resistors are supplied with each system.

Also available is the EEC double-pole connection; both resistors are 1.5K.

For Double-Pole wiring, connect the two resistors (use the ALARM ‘C’ and ‘NC’ contacts) to Alarm and Tamper.

Page 19: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

Double-Pole mode II (AV-2008, AV-2016)

Double-Pole wiring shown in the drawing is European version, when both Alarm and Tamper has equal value of 1.5K:

Tamper Alarm Power

Zone Input -V Zone Common

1.5K Ohm 1.5K Ohm

N.C. C N.C. C -V +V

+12V

PIR Sensors wires Terminal

Page 20: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

Looking for professional PIR? Try the Eye-Spy II

Save time! Use the EYS II, the only PIR with digital processing ASIC, install and forget.

Available in Quad Pet version for Pet immune and windy applications.

Page 21: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

KeypadsKeypad WiringDon’t connect the keypad when the power is on. Don’t mix LED and LCD keypad in the same system.AV-2008/88 Control Panels supports:Three AV-701TS/TIor Five AV-702

AV-2008 Dublo Control Panels supports: Five AV-707/706/705 Keypads

AV-707, AV-706, AV-705 operates only with PRO and Dublo panels.

LCD keypad (AV-707, AV-706, AV-705) cannot be connected in same system with AV-701 or AV-702.If few keypads are used for one system, connect them all in parallel.

AV-707 LCD keypad

Page 22: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

Keypad Wiring II

How to prevent keypad protection to fail?Keep the colors Red as (+), Black as (-), YEL as Yellow and OR as Orange.

Never make connection with power on.

Never power wires with no keypad connected, slices may cause short.

Shorts between power and data wires will burn the protection resistors.

Don’t power sensors or other devices from the keypad power terminals.

Page 23: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

Keypad Wiring III

This is the correct wiring way

*

7

4

1Siren

DelayDelete

Test

ARMED STATUS SHUNT FIRE

EASYLOADER AV-701AV-GAD

DISPLAYZONE

Telephone

Shunt

ResetProgram

Chime

StatusDisplayShunt 3

6

9

#

2

5

8

0

AV-GAD EASYLOADER AV-701

FIRESHUNTSTATUSARMED

Test

DeleteDelay

Siren 1

4

7

* 0

8

5

2

#

9

6

3ShuntDisplay Status

Chime

Program Reset

Shunt

Telephone

ZONEDISPLAY

Control Panel

AV-701 Keypad

Page 24: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

Keypad Wiring IV

Don’t do it, even if saves time

*

7

4

1

0

8

5

2

#

9

6

3SirenShuntDisplay Status

DelayDelete Chime

Test Program Reset

Shunt

Telephone

ARMED STATUS SHUNT FIREZONEDISPLAY

EASYLOADER AV-701AV-GAD AV-GAD EASYLOADER AV-701

FIRESHUNTSTATUSARMED

Test

DeleteDelay

Siren 1

4

7

*

DISPLAYZONE

Telephone

Shunt

ResetProgram

Chime

StatusDisplayShunt 3

6

9

#

2

5

8

0

Control Panel

W R O N G!

Page 25: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

Keypad LEDs Indicators

Red Armed/Alarm Indicator. Lights up when system is armed, and blinks after an alarm is triggered at any zone. Blinking indicates alarm history in memory.Green STATUS Indicator. Blinks when zone/s is/are troubled, remains lit as long as zones are not troubled, rapid blinking during Tamper alarm.Yellow SHUNT (Bypass) Indicator. Lights up upon zone bypass.

Red FIRE (Trouble) Indicator. Rapid blinking when a Fire Zone is troubled.

Page 26: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

Keypad LEDs Indicators II

Two LEDs flashing (Left Most LEDs) ‑ In user code programming mode, rapid blinking indicates code or code index to be entered.

Three LEDs Flashing ‑ In Disarmed mode, rapid blinking indicates AC power failure. The LEDs will blink for six seconds every minute (to save energy).

Four LEDs Flashing ‑ Upon holding-down key ‘8,’ (program mode entry) the system is ready for code to be entered. (Same LED indication when code is expected for Bypass via code.)

Page 27: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

Siren Connection

Av-Gad control panels contains two siren/bell outputs (AV-2004/48 has one siren output), individually protected by a fuse.It’s recommended to use the same type (DC 12V) of siren or bell for both internal and external sounders.

Siren mode is default-set at factory. In Siren mode, install speaker-type sirens, which DO NOT contain sound driver or electronic modules. In Bell mode install a 12V DC sounder.

Page 28: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

Siren Connection II

Consider using one internal and one external siren/bell. As Siren, use 12V DC type, or speaker siren type with a minimum power of 15W, and 8 Ohms impedance. Default is set for 12V DC siren, called Bell mode.

Enclose the outdoor siren in a metal housing, with Tamper switch for protection.The alarm from the Siren differs according to the type of zone: 24H, Fire, Burglary when using Bella AC or speaker type siren (not in Bell Mode).‘Bell Mode‘ converts Siren outputs into approximately 13V DC outputs (no sound is issued). Bell mode is applicable for driving self-powered sirens or bells, or combined sirens and strobes.

Page 29: Press F5 to view click arrows for next page Av-Gad Systems Ltd

Siren Voltage

By default hardware is set to drive 12V sirens, fits siren and bell rated at 12V DC. Bella sirens are fully compatible, for either outdoor and indoor applications.

Consider that low quality sirens are risky to use, it cause EMI problems, consume high current and other un-expected problems.

For speaker type siren set the panel software program accordingly.

TECHNICAL

Page 30: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

Panel Outputs

Remote Indication

ON - Programmable. (‑V) on closing (Arming). Optional: Drives SVM-40 voice moduleA1 - Programmable. (‑V) during alarm from the programmed zoneSLO - Programmable. (‑V) during alarm from the programmed zoneSLO Reset only upon disarming. The SLO is a non-timed output.Use the SLO output to drive a low current Strobe Light (Xenon) that consumes up to 300 mA.Each output carries more than one function; refer to programming table.

Page 31: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

Remote Indication IIHow to prevent damaging the remote indications outputs?Before connecting any device to the outputs, make sure polarity is correct and current consumption is within the maximum ratings.

Warning: The remote indications are capable of driving maximum 300 mA.

Overloading or applying +12V to the remote indications is dangerous and not assured.

If burning smell is felt, power-down immediately.

Page 32: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

GroundingThe control panel must be earth grounded for lightning protection to work effectively, and in order to prevent RFI and EMI interfaces.

Attach the ground connection to a verified cold-water pipe using a minimum 16 AWG (or larger) wire, or according to the country grounding standard. Run the ground wire via the shortest possible route.Connect the Grounding wire to main board and to the metal box. Connect the Ground wire to the terminal marked . This is not a Minus (-V).Beware of static discharge; before handling the main board touch a grounded metal.

Page 33: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

TelephoneConnect the control panel to an independent telephone line, if a device is in parallel with the alarm panel, this may grab the call first (like a message answer/fax) during remote up and download. Don’t connect fax or answering machine in parallel on the same telephone line.

Dialer – Call any phone and sounds siren sound or voice message if SVM module is included.

Communicator – Reports to central station (shortening CS). Contact ID is the most useful and fast to program. Av-Gad panels support most other CS reporting protocols.

Page 34: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

Telephone II

Do not connect to ISDN or other digital telephone system. Most ISDN converters have an Analog line; connect the Analog line of the ISDN to the TEL-LINE terminal at the panel.Option: To monitor the telephone line add the Tele-Spy, it is a 24H telephone line monitor separate module. Line monitor via software is included.How to prevent lightning from damaging the control panel? 1st, is a good grounding. 2nd, for external phone lines (not buried in the ground) use the Surgo TM line protection module.

Page 35: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

Telephone III – Why GSM?

For higher security it’s good to have a GSM backup, it means that if the wired phone line (PSTN) is cut or fail the system dials to the customer via GSM.The dials to the users (up to 4 or more numbers) and generate siren sound to indicate alarm is on. Voice module is optional.

Remote DTMF commands via telephone The user is capable to remotely command the

system from his mobile phone; arm, disarm, bypass zone and even ask the system for the current status; Armed or Disarmed.

Page 36: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

Keypad Hold Down Functions

Hold the key for 2-3 seconds until the long beep is over.Key 1 Siren TestKey 2 Shunt DisplayKey 3 Status DisplayKey 4 Delay Delete (Instant Protection)Key 5 Door Chime. Confirmed by ‘c’ display on keypad Key 6 Dialer Test & Follow-Me Programming

Page 37: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

Keypad Hold Down Functions

ProgrammingKey 7 Fault Find. Can be entered only during 15 seconds after disarmingKey 8 ProgramKey 9 ResetKey 0 Concise Alarm HistoryKey 0 then Key 0 Detailed Events History. Hold down key ‘0’ and again hold-down key ‘0’ to display up to 99 events

Page 38: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

Programming Tips

Address ‑ a location on the programming sheet.Addresses reside between 010 and 380.

Value ‑ determines the characteristics of an address.

Starting – Prior to programming mark the required setting in the programming sheet, it helps to prevent mistakes.

Page 39: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

Programming Table

The program determines most of the control panel features. Programming is performed in orderto enable maximum compatibility of the control panel with the specific site.

The control panel is supplied with the basic ‘Factory Default Program,’ which is in effect at systempower up.

Page 40: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

Programming Table II

Explain the different programming logic in the following tables:Zone FeaturesFew features per addressSingle address (time outs)How to notice the defaults

Internal system software check the most conflicts, however, we found cases that a wrong programming caused problems.

Many problems caused by wrong programming! if system operates strangely, check the wiring

first, then try to default the system.

Page 41: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

Programming Table III

In case you made programming changes and the system operation is wrong, it’s recommended to set system to the factory defaults program.

Warning! This function erases all codes and settings.

1. Enter program mode.

2. AV-2008: Go to address 200 and enter ‘6’ and ‘9.’ AV-2004: Go to address 200 and enter ‘6’ and ‘9.’

Page 42: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

System Codes

Up to eight (sixteen in 2016) different Arming & Disarming codes and one installer (dealer) code are available; each code consists of 1 to 6 digits.Do not use ‘0’ as the first digit in a code. Do not use ‘5’ and ‘0’ as first digit in a code number.User code must not start with the same numbers as the installer programming code (1994).Do not use same codes or same first digit for different codes. For example if code No. 1 is 1234, do not program other code to be 1256.Remember! Change the master user code!

Page 43: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

System Codes II

In case you lost the codes or you prefer to start over the codes setting, follow the default codes settings:

Power up by applying AC and battery and immediately hold-down keys # and * after 2nd beep, release keys. You have limited time for setting.‘U’ will be displayed 3 times in confirmation.

Make sure not to change the feature that provides setting of the default codes, refer to “Enable-codes reset to default by * & #” at address 72 value 8.

Page 44: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

System Codes III

In case the keypad entries stopped reacting, it’s probably a blocked keypad. Wait 5 minutes or power up.Keypad Keys self-locking:In Armed and Disarmed mode, after 6 attempts to enter fault code, the keys will not react to any key press. This prevents code learning or other code break exigency. After a 30 seconds delay, the keys will revert to code entry mode. Each new erroneous code will lock the system for another 30 seconds.

Explain this point to your customer.

Page 45: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

Up and Download

Most common problem is the PC modem - Use the correct modem.To program EasyLoader control panel by remote PC, a compatible modem is required. The modem specifications is critical, before attempting to operate the EasyLoader make sure your modem meets the following: Supports the Hayes AT command, Bell 103 compatible, DOS mode is selectable. New Windows Beta version is available.

The old EasyLoad software is a Window or DOS based program. Why DOS? It’s compatible with most old laptops, DOS is not upgraded frequently, no viruses and the program files are compact and easy to transfer via internet.

Page 46: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

Up and Download II

Note: Series 3000 is not ready for up & download

Configure your communication port using the SET-UP entry from the main menu (entry 7).

For DOS mode; the PC modem required COM/IRQ combinations are:

COM1, COM3 - IRQ 4COM2, COM4 - IRQ 3

To initialized the modem properly use the Auto Detect option before trying to CONNECT, ignore errors that are reported during initialization.

Page 47: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

What about wirelessWireless is great, fast to install and save the wiring, your labor time saved, but it’s very important to consider:

- In certain areas with crowded RF spectrum the wireless can’t be operated

- Service rate is higher - Requires pre-installation programming - Reliability is lower - Cost three times higher than wired Consider wired as better security at

lower price, it’s a fact.

Page 48: Press F5 to view click arrows for next page Av-Gad Systems Ltd

TECHNICAL

Up and Download III

Operate the EasyLoad on the demonstration PC and show screen by screen the functions.

Still need more details? Try our FAQ section at Av-Gad web site, support section