PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
Miniature Split-core AC Current Transformer is suitable for primary ranges from 5A to 2,400A AC with mA, 0.1A, 1A, 5A, 333mV AC secondary.It improves both intrinsic errors in low current and errors occurred by external vibration and shock with strong durability and minimum tolerance on cutting cross section of core. Main applications are sub metering, power meter, PLC (Programmable Logic Controller), energy automation and etc.
JSC-01
-250-3
33mV
250A
: 333
mV
Lot n
o : 12
0601
IEC60
044-1
clas
s 0.5,
0.5V
A
F=50/6
0Hz
Umax=7
20V U
i=3kV
Source Side
S1 :
White
S2 :
Blac
k
E3446
23
JSC-02
-400-3
33mV
400A
: 333
mV
Lot n
o : 12
0601
IEC60
044-1
clas
s 0.5,
0.5V
A
F=50/6
0Hz
Umax=7
20V U
i=3kV
Source Side
S1 :
White
S2 :
Blac
k
E3446
23
JSC-03
-800-3
33mV
800A
: 333
mV
Lot n
o : 12
0601
IEC60
044-1
clas
s 0.5,
0.5V
A
F=50/6
0Hz
Umax=7
20V U
i=3kV
Source Side
S1 :
White
S2 :
Blac
k
E3446
23
600VAC Max. CAT
Additional isolation must be provided
if used at higher voltages.
P1
P2
600VAC Max. CAT
Additional isolation must be provided
if used at higher voltages.
P1
P2
600VAC Max. CAT
Additional isolation must be provided
if used at higher voltages.
P1
P2
JS24S-250/5A
S1 S2
250A : 5A Lot no:120601IEC60044-1 class 1.0, 1.0VA F=50/60Hz Umax=720V Ui=3kV JS24S-250/1A
S1 S2
250A : 1A Lot no:120601IEC60044-1 class 1.0, 0.2VAF=50/60Hz Umax=720V Ui=3kV
2PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
JC08W-mA Series
JS08W-mA Series
JSXXFL-XXX/XXXmA series
JSXXNL-XXX/XXXmA series
JSXXSL-XXX/XXXmA series
JCXXF-XXXmA series
JCXXFL-XXX-XXXmA series
JC24S-1/2/3 series
JC36S-1/2/3 series
JCXXF-333mV series
JCXXFL-333mV series
JSXXF-XXX-333mV series
JSXXS-XXX-333mV series
JSXXFL-XXX-333mV series
JSXXNL-XXX-333mV series
JSXXSL-XXX-333mV series
JM21X-XXX-333mV series
JSC-XX-XXXX-333mV series
JSC-XXN-XXXX-333mV series
JCXXF-XXX-100mA series
43
45
47
49
51
53
55
57
59
61
63
65
67
69
71
73
75
77
79
81
JCXXN-XXX-100mA series
JSXXF-XXX-100mA series
JSXXS-XXX-100mA series
JSXXFL-XXX-100mA series
JSXXNL-XXX-100mA series
JSXXSL-XXX-100mA series
JM21X-XXX-100mA series
JSC-XX-XXXX-100mA series
JSC-XXN-XXXX-100mA series
JCXXS-XXX-1A series
JSXXS-XXX-1A series
JS18S-XXX-1A series
JM21N-XXX-1A series
JSC-XX-XXXX-1A series
JSXXS-XXX-5A series
JSXXS-XXX-5A series
JSC-XX-XXXX-5A series
JSXXL-XXX-100mA series
JSXXL-XXX-1A series
JSXXL-XXX-5A series
SPLIT-CORE CURRENT TRANSFORMER
CONTENTS
APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system
FEATURES• Ø5~ Ø8.5mm sensing aperture for non-contact measurement
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation
3 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
HOW TO USE
SPLIT-CORE CURRENT TRANSFORMER
JC08W-mA Series
• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side. • Do not use any other chemicals except WD-40 or CRC5-56 on housing or any parts.• Additionally, CTs are deliverable with customized output lead cable.• Silicone rubber reducing sleeves for central positioning of thinner conductors (5.5mm~6.5mm) are optional available.
30A/10mA
0.01~45A (RL=1Ω)
70A
+1±1˚
-0.5 ~ ±1%
3000:1
240±24Ω
SPECIFICATION
ModelJC08W-25
Ø8.5
Current Ratio
Current Range
Max Continuous Current
Nominal Phase Angle Error
Nominal Linearity Error
Turns Ratio
DCR
Protection Level
Insulation Category
Operating Condition
Storage Condition
25A/10mA
0.01~42A (RL=1Ω)
70A
+1±1˚
-1.5 ~ ±0.5%
2500:1
200±20Ω
Over-voltage protection circuit is not included, please pay careful attention during installation.
CATⅢ 600V AC / PD2
-20˚C~+50˚C, ≤85%RH, No condensation, In-house & Any direction installable
-30˚C~+90˚C, ≤85%RH, No condensation
JC08W-30
Ø8.5
(F=50/60Hz)
4PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
ACCURACY DATA
APPLICATIONS / DIMENSIONS
7.99.5
15.0
16.0
P2 P1
S2
Black White
S1
I
* Unit : mm
1.3
R2
9.5
8
16
Ø 5
Ø 1.6
Ø 6.5
26
9
5.2
10
15
5
R2
Black(S2)
White(S1)
LOAD
CurrentMonitoring
POWER
Output FrequencyOutput Voltage@RL=1ΩLinearity & Phase Angle ErrorModel
JC08W-25
110 100 1000 104 105
10
100
1000Io=25Arms
1 Ω
Primary Current@50Hz(I)
Seco
nd
ary
Volt
age(
mV
)0.1
0.1 1 10 100 1000
1
10
100
1000
1 Ω
Rated Current : 25A/0.0001VA@50Hz
F(I)
[%]&
f[˚]
@25
C
f(Hz)
Seco
nd
ary
Volt
age(
mV
)
-21 105 20 100 15050 120 200
-1
0
1
2
IEC60044-1 P h a s eAmplitude
JC08W-30
110 100 1000 104 105
10
100
1000Io=30Arms
1 Ω0.10.1 1 10 100 1000
1
10
100
1000
1 Ω
Primary Current@50Hz(I)
Seco
nd
ary
Volt
age(
mV
)
Rated Current : 30A/0.0001VA@50Hz
F(I)
[%]&
f[˚]
@25
C
f(Hz)Se
con
dar
y Vo
ltag
e(m
V)
-21 105 20 100 15050 120 200
-1
0
1
2
IEC60044-1 P h a s eAmplitude
SPECIFICATION
ModelJS08W-25
Ø8.5
Current Ratio
Current Range
Max Continuous Current
Nominal Phase Angle Error
Nominal Linearity Error
Turns Ratio
DCR
Protection Level
Insulation Category
Operating Condition
Storage Condition
25A/10mA
0.01~42A (RL=1Ω)
70A
+1±1˚
-0.5 ~ ±1%
2500:1
200±20Ω
30A/10mA
0.01~45A (RL=1Ω)
70A
+1±1˚
-0.5 ~ ±1%
3000:1
240±24Ω
Over-voltage protection circuit is not included, please pay careful attention during installation
CATⅢ 600V AC / PD2
-20˚C~+50˚C, ≤85%RH, No condensation, In-house & Any direction installable
-30˚C~+90˚C, ≤85%RH, No condensation
JS08W-30
Ø8.5
(F=50/60Hz)
• Output-lead-wire, secure locking hinge, flat screw clip type make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified
APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation
HOW TO USE
SPLIT-CORE CURRENT TRANSFORMER
JS08W-mA Series
• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side. • Do not use any other chemicals except WD-40 or CRC5-56 on housing or any parts.• Additionally, CTs are deliverable with customized output lead cable.
The split-core current transformer design is used for energy efficiency monitoring and automation applications. This includes sub-metering cost allocation, dynamic energy consumption and peak load analysis. The JS series of current transformer is simple to use, compact split-core design which is easily installed for metering applications. This is ideal for distributed measurement systems and can be retro-fitted into existing installations and non-interruptible equipment as there is no requirement for discon-nection and reconnection of wiring.
2
3 4
1
OPEN
Flat-headScrewdriver
CLOSE
Flat-headScrewdriver
5 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
ACCURACY DATA
6PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
1000 ± 50
AWG#22
Relay cable(common)(attached with CT)
Housing : 5480-02(Molex.Inc.)Terminal : 5479PBT(Molex.Inc.)
Whitewire
Blackwire
3410
50 ±
20
6
8.5 15
Plug housing :SLP-02V
P2 P1
P2
Black(S2)
White(S1)
P1
I
P2 P1
AWG#22
OPTIONLOAD
CurrentMonitoring
S2S1
POWER
Output FrequencyOutput Voltage@RL=1ΩLinearity & Phase Angle ErrorModel
JS08W-25
110 100 1000 104 105
10
100
1000Io=25Arms
1 Ω
Primary Current@50Hz(I)
Seco
nd
ary
Volt
age(
mV
)0.1
0.1 1 10 100 1000
1
10
100
1000
1 Ω
Rated Current : 25A/0.0001VA@50Hz
F(I)
[%]&
f[˚]
@25
C
f(Hz)
Seco
nd
ary
Volt
age(
mV
)
-21 105 20 100 15050 120 200
-1
0
1
2
IEC60044-1 P h a s eAmplitude
JS08W-30
110 100 1000 104 105
10
100
1000Io=30Arms
1 Ω0.10.1 1 10 100 1000
1
10
100
1000
1 Ω
Primary Current@50Hz(I)
Seco
nd
ary
Volt
age(
mV
)
Rated Current : 30A/0.0001VA@50Hz
F(I)
[%]&
f[˚]
@25
C
f(Hz)Se
con
dar
y Vo
ltag
e(m
V)
-21 105 20 100 15050 120 200
-1
0
1
2
IEC60044-1 P h a s eAmplitude
APPLICATIONS / DIMENSIONS
SPECIFICATION
ModelJS10FL
Ø10
Current Ratio
Current Range
Max Continuous Current
Nominal Phase Angle Error
Nominal Linearity Error
Turns Ratio
DCR
Protection Level
Insulation Category
Operating Condition
Storage Condition
50A/16.6mA
0.1~80A (RL=10Ω)
120A
+1.5±1˚
-1±1%
3000:1
360±25Ω
7.5V0-P
JS16FL
Ø16
100A/33.3mA
0.1~120A (RL=10Ω)
200A
+1.0±1˚
-1±1%
3000:1
280±20Ω
7.5V0-P
JS24FL
Ø24
200A/66.6mA
0.1~200A (RL=10Ω)
300A
+1.0±1˚
-1±1%
3000:1
171±15Ω
7.5V0-P
CATⅢ
-20˚C~+50˚C, ≤85%RH, No condensation, In-house & Any direction installable
-30˚C~+90˚C, ≤85%RH, No condensation
(F=50/60Hz)
• Output-lead-wire, secure locking hinge, one-touch structure make easy to install to the existent equip• ments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified
7 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
HOW TO USE
SPLIT-CORE CURRENT TRANSFORMER
JSXXFL-XXX/XXXmA series
• If you impact the core contact surface, internal core material could be damaged. • Additionally, CTs are deliverable with customized output lead cable.
JS series of split-core current transformer offers XXXmA at secondary from sensed primary current for metering application. Without using secondary CT inside of meter, it enables one meter to be adopted for various current rating by only changing primary CT so it makes compact meter design and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation. Especially JS10FL can be installed at secondary of 5A output primary CT to compare meter's accuracy.
ACCURACY DATA
APPLICATIONS / DIMENSIONS
8PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
Output FrequencyOutput VoltageLinearity & Phase Angle ErrorModel
JS10FL
JS24FL
JS16FL
10.1 1 10 100 1000
10
100
1000
1041 0 Ω100Ω1 K Ω
10.1 1 10 100 1000
10
100
1000
101 0 Ω100Ω1 K Ω
110 100 1000 104 105
10
1000Io=10Arms
1 0 Ω100Ω
10.1 1 10 100 1000
10
100
1000
101 0 Ω100Ω1 K Ω
110 100 1000 104 105
10
100
1000Io=1Arms
1 0 Ω100Ω1 K Ω
110 100 1000 104 105 106
10
100
1000Io=1Arms
1 0 Ω100Ω1 K Ω
Primary Current@50Hz(I)
Seco
nd
ary
Volt
age(
mV
)
Primary Current@50Hz(I)
Seco
nd
ary
Volt
age(
mV
)
Primary Current@50Hz(I)
Seco
nd
ary
Volt
age(
mV
)
Rated Current : 50A/0.002VA@50Hz
F(I)
[%]&
f[˚]
@25
C
Rated Current : 100A/0.002VA@50Hz
F(I)
[%]&
f[˚]
@25
C
Rated Current : 200A/0.02VA@50Hz
F(I)
[%]&
f[˚]
@25
C
f(Hz)
Seco
nd
ary
Volt
age(
mV
)f(Hz)
Seco
nd
ary
Volt
age(
mV
)
f(Hz)
Seco
nd
ary
Volt
age(
mV
)
-21 105 20 100 15050 120 200
-1
0
1
2IEC60044-1 P h a s e
Amplitude
-21 105 20 100 15050 120 200
-1
0
1
2IEC60044-1 P h a s e
Amplitude
-21 105 20 100 15050 120 200
-1
0
1
2IEC60044-1 P h a s e
Amplitude
Unit : mm
ModelJS10FLJS16FLJS24FL
A40.54565
B2326
37.5
C23.73045
D26.631.633.7
E14.518.821.1
F150±20150±20200±20
Ød101624
BipolarDirectionalZenor Diode
White wire
(S1)Black wire
(S2)
P1 P2
ED
P2
P1
1000
± 5
0
AWG
#22
Relay cable(common)(attached with CT)
Receptacle housing :SLR-02VFPin contact :SSM-21T-P1.4
Housing : 5480-02(Molex.Inc.)Terminal : 5479PBT(Molex.Inc.)
A F
B
C Φd
10FL/16FLAWG#2224FLAWG#18
Plug housing :SLP-02VSocket connector : SSF-21T-P1.4
Whi
te w
ire
(S1)
Blac
k w
ire
(S2)
OPTION
LOAD
S1 S2
CONTACTOR
CurrentMonitoring
POWER
9 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
SPECIFICATION
ModelJS10NL
Ø10
Current Ratio
Current Range
Max Continuous Current
Nominal Phase Angle Error
Nominal Linearity Error
Turns Ratio
DCR
Protection Level
Insulation Category
Operating Condition
Storage Condition
50A/16.6mA
0.1~80A (RL=10Ω)
120A
+1.5±1˚
-1±1%
3000:1
360±25Ω
7.5V0-P
JS16NL
Ø16
100A/33.3mA
0.1~120A (RL=10Ω)
200A
+1.0±1˚
-1±1%
3000:1
280±20Ω
7.5V0-P
JS24NL
Ø24
200A/66.6mA
0.1~200A (RL=10Ω)
300A
+1.0±1˚
-1±1%
3000:1
171±15Ω
7.5V0-P
CATⅢ
-20˚C~+50˚C, ≤85%RH, No condensation, In-house & Any direction installable
-30˚C~+90˚C, ≤85%RH, No condensation
(F=50/60Hz)
• Output-lead-wire, secure locking hinge, one-touch structure make easy to install to the existent equip• ments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified
APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
HOW TO USE
SPLIT-CORE CURRENT TRANSFORMER
JSXXNL-XXX/XXXmA series
• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side. • Do not use any other chemicals except WD-40 or CRC5-56 on housing or any parts.• Customizing output lead wire
JS series of split-core current transformer offers XXXmA at secondary from sensed primary current for metering application. Without using secondary CT inside of meter, it enables one meter to be adopted for various current rating by only changing primary CT so it makes compact meter design and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation. Especially JS10NL can be installed at secondary of 5A output primary CT to compare meter's accuracy.
ACCURACY DATA
APPLICATIONS / DIMENSIONS
10PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
Output FrequencyOutput VoltageLinearity & Phase Angle ErrorModel
JS10NL
JS24NL
JS16NL
10.1 1 10 100 1000
10
100
1000
1041 0 Ω100Ω1 K Ω
10.1 1 10 100 1000
10
100
1000
101 0 Ω100Ω1 K Ω
110 100 1000 104 105
10
1000Io=10Arms
1 0 Ω100Ω
10.1 1 10 100 1000
10
100
1000
101 0 Ω100Ω1 K Ω
110 100 1000 104 105
10
100
1000Io=1Arms
1 0 Ω100Ω1 K Ω
110 100 1000 104 105 106
10
100
1000Io=1Arms
1 0 Ω100Ω1 K Ω
Primary Current@50Hz(I)
Seco
nd
ary
Volt
age(
mV
)
Primary Current@50Hz(I)
Seco
nd
ary
Volt
age(
mV
)
Primary Current@50Hz(I)
Seco
nd
ary
Volt
age(
mV
)
Rated Current : 50A/0.002VA@50Hz
F(I)
[%]&
f[˚]
@25
C
Rated Current : 100A/0.002VA@50Hz
F(I)
[%]&
f[˚]
@25
C
Rated Current : 200A/0.02VA@50Hz
F(I)
[%]&
f[˚]
@25
C
f(Hz)
Seco
nd
ary
Volt
age(
mV
)
f(Hz)
Seco
nd
ary
Volt
age(
mV
)
f(Hz)
Seco
nd
ary
Volt
age(
mV
)
-21 105 20 100 15050 120 200
-1
0
1
2IEC60044-1 P h a s e
Amplitude
-21 105 20 100 15050 120 200
-1
0
1
2IEC60044-1 P h a s e
Amplitude
-21 105 20 100 15050 120 200
-1
0
1
2IEC60044-1 P h a s e
Amplitude
Unit : mm
ModelJS10NLJS16NLJS24NL
A40.54565
B2326
37.5
C23.73045
D26.631.633.7
E14.518.821.1
F150±20150±20200±20
Ød101624
BipolarDirectionalZenor Diode
White wire
(S1)Black wire
(S2)
P1 P2
ED
P2
P1
1000
± 5
0
AWG
#22
Relay cable(common)(attached with CT)
Receptacle housing :SLR-02VFPin contact :SSM-21T-P1.4
Housing : 5480-02(Molex.Inc.)Terminal : 5479PBT(Molex.Inc.)
A F
B
C Φd
10NL/16NLAWG#22JS24NLAWG#18
Plug housing :SLP-02VSocket connector : SSF-21T-P1.4
Whi
te w
ire
(S1)
Blac
k w
ire
(S2)
OPTION
LOAD
S1 S2
CONTACTOR
CurrentMonitoring
POWER
SPECIFICATION
ModelJS24SL
Ø24
Current Ratio
Current Range
Max Continuous Current
Nominal Phase Angle Error
Nominal Linearity Error
Turns Ratio
DCR
Protection Level
Insulation Category
Operating Condition
Storage Condition
250A/125mA
0.1~300A (RL=5Ω)
360A
+0.5±0.5˚
±1%
2000:1(Winding : 1980T)
70±5Ω
400A/200mA
0.1~500A (RL=5Ω)
600A
+0.5±0.5˚
±1%
2000:1(Winding : 1970T)
33±4Ω
3.0V0-P
CATⅢ
-20˚C~+50˚C, ≤85%RH, No condensation, In-house & Any direction installable
-30˚C~+90˚C, ≤85%RH, No condensation
JS36SL
Ø36
(F=50/60Hz)
• Output-lead-wire, secure locking hinge, one-touch structure make easy to install to the existent equip-ments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified
11 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
HOW TO USE
SPLIT-CORE CURRENT TRANSFORMER
JSXXSL-XXX/XXXmA series
• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side. • Do not use any other chemicals except WD-40 or CRC5-56 on housing or any parts.• Customizing out put lead wire
JS series of split-core current transformer offers XXXmA at secondary from sensed primary current for metering application. Without using secondary CT inside of meter, it enables one meter to be adopted for various current rating by only changing primary CT so it makes compact meter design and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.
ACCURACY DATA
APPLICATIONS / DIMENSIONS
12PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
Output FrequencyOutput VoltageLinearity & Phase Angle ErrorModel
JS24SL
110 100 1000 104 105
10
100
1000Io=10Arms
1 0 Ω100Ω
Primary Current@50Hz(I)
Seco
nd
ary
Volt
age(
mV
)1
0.1 1 10 100 1000
10
100
1000
10
5 Ω
Rated Current : 300A/0.18VA@50Hz
F(I)
[%]&
f[˚]
@25
C
f(Hz)
Seco
nd
ary
Volt
age(
mV
)
-21 105 20 100 15050 120 200
-1
0
1
2
IEC60044-1 P h a s eAmplitude
JS36SL
110 100 1000 104 105
10
100
1000Io=10Arms
1 0 Ω100Ω
10.1 1 10 100 1000
10
100
1000
10
5 Ω
Primary Current@50Hz(I)
Seco
nd
ary
Volt
age(
mV
)
Rated Current : 500A/0.31VA@50Hz
F(I)
[%]&
f[˚]
@25
C
f(Hz)Se
con
dar
y Vo
ltag
e(m
V)
-21 105 20 100 15050 120 200
-1
0
1
2
IEC60044-1 P h a s eAmplitude
Unit : mm
ModelJS24SL
A65
B37.5
C45
D33.7
E21.1
Ød24
JS36SL 82.4 48 57.1 40.2 21.1
F200±20200±20 36
BipolarDirectionalZenor Diode
White wire
(S1)Black wire
(S2)
P1 P2
ED
P2
P1
1000
± 5
0
AWG
#22
Relay cable(common)(attached with CT)
Receptacle housing :SLR-02VFPin contact :SSM-21T-P1.4
Housing : 5480-02(Molex.Inc.)Terminal : 5479PBT(Molex.Inc.)
A F
B
C Φd
24SL/36SLAWG#18
Plug housing :SLP-02VSocket connector : SSF-21F-P1.4
Whi
te w
ire
(S1)
Blac
k w
ire
(S2)
OPTION
LOAD
S1 S2
CONTACTOR
CurrentMonitoring
POWER
SPECIFICATION
ModelJC10F
Ø10
Current Ratio
Current Range
Max Continuous Current
Nominal Phase Angle Error
Nominal Linearity Error
Turns Ratio
DCR
Protection Level
Insulation Category
Operating Condition
Storage Condition
50A/16.6mA
0.1~80A (RL=10Ω)
120A
+1.5±1˚
-1±1%
3000:1
360±25Ω
7.5V0-P
JC16F
Ø16
120A/40mA
0.1~120A (RL=10Ω)
200A
+1.0±1˚
-1±1%
3000:1
280±20Ω
7.5V0-P
JC24F
Ø24
200A/66.6mA
0.1~200A (RL=10Ω)
300A
+1.0±1˚
-1±1%
3000:1
171±15Ω
7.5V0-P
CATⅢ
-20˚C~+50˚C, ≤85%RH, No condensation, In-house & Any direction installable
-30˚C~+90˚C, ≤85%RH, No condensation
(F=50/60Hz)
• Nylon-spring, output-terminal, secure locking hinge, one-touch structure makes easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 -1 certified
APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
HOW TO USE
SPLIT-CORE CURRENT TRANSFORMER
JCXXF-XXXmA series
• If you impact the core contact surface, internal core material could be damaged.• Please use only the original output screws. Not recommanded to replace it with anything else.• Customizing output lead wire
The split-core current transformer design is used for energy efficiency monitoring and automation applications. This includes sub-metering cost allocation, dynamic energy consumption and peak load analysis. The JC series of current transform-er is simple to use, compact split-core design which is easily installed for metering applications. This is ideal for distributed measurement systems and can be retro-fitted into existing installations and non - interruptible equipment as there is no requirement for disconnection and reconnection of wiring.
2 3
4 5 6
1
P2 P1
METER
S1 S2 M3-Screwdriver
8mm
Terminalcover
CLOSE
Terminalcover
OPEN
13 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
50A : 16.6mAJD150310
JC10F
S1 S2E344623
50A : 16.6mAJD150310
JC10F
S1 S2E344623
50A : 16.6mAJD150310
JC10F
S1 S2E344623
200A : 66.6mAJD150310
JC24F
S1 S2E344623
120A : 40mAJD150310
JC16F
S1 S2E344623
ACCURACY DATA
APPLICATIONS / DIMENSIONS
14PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
Output FrequencyOutput VoltageLinearity & Phase Angle ErrorModel
JC10F
JC24F
JC16F
10.1 1 10 100 1000
10
100
1000
1041 0 Ω100Ω1 K Ω
10.1 1 10 100 1000
10
100
1000
101 0 Ω100Ω1 K Ω
110 100 1000 104 105
10
1000Io=10Arms
1 0 Ω100Ω
10.1 1 10 100 1000
10
100
1000
101 0 Ω100Ω1 K Ω
110 100 1000 104 105
10
100
1000Io=1Arms
1 0 Ω100Ω1 K Ω
110 100 1000 104 105 106
10
100
1000Io=1Arms
1 0 Ω100Ω1 K Ω
Primary Current@50Hz(I)
Seco
nd
ary
Volt
age(
mV
)
Primary Current@50Hz(I)
Seco
nd
ary
Volt
age(
mV
)
Primary Current@50Hz(I)
Seco
nd
ary
Volt
age(
mV
)
Rated Current : 50A/0.002VA@50Hz
F(I)
[%]&
f[˚]
@25
C
Rated Current : 100A/0.002VA@50Hz
F(I)
[%]&
f[˚]
@25
C
Rated Current : 200A/0.02VA@50Hz
F(I)
[%]&
f[˚]
@25
C
f(Hz)
Seco
nd
ary
Volt
age(
mV
)f(Hz)
Seco
nd
ary
Volt
age(
mV
)
f(Hz)
Seco
nd
ary
Volt
age(
mV
)
-21 105 20 100 15050 120 200
-1
0
1
2IEC60044-1 P h a s e
Amplitude
-21 105 20 100 15050 120 200
-1
0
1
2IEC60044-1 P h a s e
Amplitude
-21 105 20 100 15050 120 200
-1
0
1
2IEC60044-1 P h a s e
Amplitude
CONTACTOR
CurrentMonitoring
LOAD
POWER
BipolarDirectionalZenor Diode
M3 Screw M3 Screw
P2 P1
S2 S1
J&D
S2S1
E
D C
B
A
Φd
S2S1
Unit : mm
ModelJC10FJC16FJC24F
A5055
74.5
B384152
C23
29.545
D263134
E14.51922
Ød101624
P2 P1
SPECIFICATION
ModelJC10FL
Ø10
Current Ratio
Current Range
Max Continuous Current
Nominal Phase Angle Error
Nominal Linearity Error
Turns Ratio
DCR
Protection Level
Insulation Category
Operating Condition
Storage Condition
50A/16.6mA
0.1~80A (RL=10Ω)
120A
+1.5±1˚
-1±1%
3000:1
420±30Ω
7.5V0-P
100A/33.3mA
0.1~120A (RL=10Ω)
200A
+1.0±1˚
-1±1%
3000:1
290±25Ω
7.5V0-P
CATⅢ
-20˚C~+50˚C, ≤85%RH, No condensation, In-house & Any direction installable
-30˚C~+90˚C, ≤85%RH, No condensation
JC16FL
Ø16
(F=50/60Hz)
• Nylon-spring, secure locking hinge, one-touch structure makes easy to install to the existent equip-ments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 -1 certified
15 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
HOW TO USE
SPLIT-CORE CURRENT TRANSFORMER
JCXXFL-XXX-XXXmA series
• If you impact the core contact surface, internal core material could be damaged.• Customizing output lead wire
The split-core current transformer design is used for energy efficiency monitoring and automation applications. This includes sub-metering cost allocation, dynamic energy consumption and peak load analysis. The JC series of current transform-er is simple to use, compact split-core design which is easily installed for metering applications. This is ideal for distributed measurement systems and can be retro-fitted into existing installations and non - interruptible equipment as there is no requirement for disconnection and reconnection of wiring.
50A : 16.6mAJD150310
JC10FL
S1 S2E344623
100A : 33.3mAJD150310
JC16FL
S1 S2E344623
2
3 4
1
P2 P1
ACCURACY DATA
APPLICATIONS / DIMENSIONS
16PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
Output FrequencyOutput VoltageLinearity & Phase Angle ErrorModel
JC10FL
JC16FL
10.1 1 10 100 1000
10
100
1000
1041 0 Ω100Ω1 K Ω
10.1 1 10 100 1000
10
100
1000
101 0 Ω100Ω1 K Ω
110 100 1000 104 105
10
100
1000Io=1Arms
1 0 Ω100Ω1 K Ω
110 100 1000 104 105 106
10
100
1000Io=1Arms
1 0 Ω100Ω1 K Ω
Primary Current@50Hz(I)
Seco
nd
ary
Volt
age(
mV
)
Primary Current@50Hz(I)
Seco
nd
ary
Volt
age(
mV
)
Rated Current : 50A/0.002VA@50Hz
F(I)
[%]&
f[˚]
@25
C
Rated Current : 100A/0.002VA@50Hz
F(I)
[%]&
f[˚]
@25
C
f(Hz)
Seco
nd
ary
Volt
age(
mV
)f(Hz)
Seco
nd
ary
Volt
age(
mV
)
-21 105 20 100 15050 120 200
-1
0
1
2IEC60044-1 P h a s e
Amplitude
-21 105 20 100 15050 120 200
-1
0
1
2IEC60044-1 P h a s e
Amplitude
CONTACTOR
CurrentMonitoring
LOAD
POWER
S2S1
JC16FL
JC10FL
18.6
0
29.40
16.20
15.7
021
.90
44.6
0
31.60
18.90
5.40
41.2
0
31.70
40.4
0
23.60
10.5
0
10
11
24.70
14.40
26.70
24.4
015
14
BipolarDirectionalZenor Diode
White wire
(S1)Black wire
(S2)
P1 P2
JD120601
S1 S2
JC24S-3300A:100mA
SPECIFICATION
ModelJC24S-1
Ø24
Current Ratio
Current Range
Max Continuous Current
Nominal Phase Angle Error
Nominal Linearity Error
Turns Ratio
DCR
Protection Level
Insulation Category
Operating Condition
Storage Condition
200A/200mA
0.1~200A (RL=5Ω)
300A
+0.5±0.5°
±1%
1000:1(Winding : 990T)
17±3Ω
3.0V0-P
JC24S-2
Ø24
300A/150mA
0.1~300A (RL=8Ω)
360A
+0.5±0.5°
±1%
2000:1(Winding : 1980T)
70±3Ω
3.0V0-P
JC24S-3
Ø24
300A/100mA
0.1~320A (RL=10Ω)
380A
+0.5±0.5°
±1%
3000:1(Winding : 2970T)
117±10Ω
3.0V0-P
CATⅢ
-20˚C~+50˚C, ≤85%RH, No condensation, In-house & Any direction installable
-30˚C~+90˚C, ≤85%RH, No condensation
(F=50/60Hz)
• Nylon-spring, output-terminal, secure locking hinge, one-touch structure makes easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 -1 certified
APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
HOW TO USE
SPLIT-CORE CURRENT TRANSFORMER
JC24S-1/2/3 series
• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side.• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any parts.• Please use only the original output screws. Not recommanded to replace it with anything else.• Customizing output lead wire
The split-core current transformer design is used for energy efficiency monitoring and automation applications. This includes sub-metering cost allocation, dynamic energy consumption and peak load analysis. The JC series of current transformer is simple to use, compact split-core design which is easily installed for metering applications. This is ideal for distributed measurement systems and can be retro-fitted into existing installations and non-interruptible equipment as there is no requirement for discon-nection and reconnection of wiring.
2 3
4 5 6
1
P2 P1
METER
S1 S2 M3-Screwdriver
8mm
Terminalcover
CLOSE
Terminalcover
OPEN
17 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
ACCURACY DATA
APPLICATIONS / DIMENSIONS
18PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
Output FrequencyOutput VoltageLinearity & Phase Angle ErrorModel
JC24S-1
JC24S-3
JC24S-2
10.1 1 10 100 1000
10
100
1000
104
10.1 1 10 100 1000
10
100
1000
10
10.1 1 10 100 1000
10
100
1000
10
Primary Current@50Hz(I)
Seco
nd
ary
Volt
age(
mV
)
Primary Current@50Hz(I)
Seco
nd
ary
Volt
age(
mV
)
Primary Current@50Hz(I)
Seco
nd
ary
Volt
age(
mV
)
Rated Current : 200A/0.2VA@50Hz
F(I)
[%]&
f[˚]
@25
C
Rated Current : 300A/0.18VA@50Hz
F(I)
[%]&
f[˚]
@25
C
Rated Current : 300A/10.1VA@50Hz
F(I)
[%]&
f[˚]
@25
C
f(Hz)
Seco
nd
ary
Volt
age(
mV
)f(Hz)
Seco
nd
ary
Volt
age(
mV
)
110 100 1000 104 105
10
100
1000Io=10Arms
1 0 Ω100Ω
110 100 1000 104 105
10
100
1000Io=10Arms
1 0 Ω100Ω
110 100 1000 104 105
10
100
1000Io=10Arms
1 0 Ω100Ω
f(Hz)
Seco
nd
ary
Volt
age(
mV
)
-21 105 20 100 15050 120 200
-1
0
1
2
IEC60044-1 P h a s eAmplitude
-21 105 20 100 15050 120 200
-1
0
1
2
IEC60044-1 P h a s eAmplitude
-21 105 20 100 15050 120 200
-1
0
1
2
IEC60044-1 P h a s eAmplitude
5 Ω
8 Ω
10Ω
LOAD
CONTACTOR
CurrentMonitoring
S1
S2
POWER
74.5
52
45
S1 S2
24
2422
34
BipolarDirectionalZenor Diode
M3 Screw M3 Screw
S2 S1
P2 P1
P2 P1
SPECIFICATION
ModelJC36S-1
Ø36
Current Ratio
Current Range
Max Continuous Current
Nominal Phase Angle Error
Nominal Linearity Error
Turns Ratio
DCR
Protection Level
Insulation Category
Operating Condition
Storage Condition
300A/300mA
0.1~300A (RL=5Ω)
400A
+0.5±0.5˚
±1%
1000:1(Winding : 990T)
7±2Ω
3.0V0-P
JC36S-2
Ø36
500A/250mA
0.1~500A (RL=5Ω)
600A
+0.5±0.5˚
±1%
2000:1(Winding : 1970T)
33±4Ω
3.0V0-P
JC36S-3
Ø36
600A/200mA
0.1~620A (RL=2Ω)
650A
+0.5±0.5˚
±1%
3000:1(Winding : 2955T)
58±7Ω
3.0V0-P
CATⅢ
-20˚C~+50˚C, ≤85%RH, No condensation, In-house & Any direction installable
-30˚C~+90˚C, ≤85%RH, No condensation
(F=50/60Hz)
19 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
• Nylon-spring, output-terminal, secure locking hinge, one-touch structure makes easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 -1 certified
APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
HOW TO USE
SPLIT-CORE CURRENT TRANSFORMER
JC36S-1/2/3 series
• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side.• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts.• Please use only the original output screws. Not recommanded to replace it with anything else.• Customizing output lead wire
The split-core current transformer design is used for energy efficiency monitoring and automation applications. This includes sub-metering cost allocation, dynamic energy consumption and peak load analysis. The JC series of current transformer is simple to use, compact split-core design which is easily installed for metering applications. This is ideal for distributed measurement systems and can be retro-fitted into existing installations and non-interruptible equipment as there is no requirement for discon-nection and reconnection of wiring.
JD120601
S1 S2
JC36S-3600A:200mA
2 3
4 5 6
1
P2 P1
METER
S1 S2 M3-Screwdriver
8mm
Terminalcover
CLOSE
Terminalcover
OPEN
20PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
ACCURACY DATA
APPLICATIONS / DIMENSIONS
Output FrequencyOutput VoltageLinearity & Phase Angle ErrorModel
JC36S-1
JC36S-3
JC36S-2
10.1 1 10 100 1000
10
100
1000
104
10.1 1 10 100 1000
10
100
1000
10
10.1 1 10 100 1000
10
100
1000
10
110 100 1000 104 105
10
100
1000Io=10Arms
1 0 Ω100Ω
110 100 1000 104 105
10
100
1000Io=10Arms
1 0 Ω100Ω
110 100 1000 104 105
10
100
1000Io=10Arms
1 0 Ω100Ω
Primary Current@50Hz(I)
Seco
nd
ary
Volt
age(
mV
)
Primary Current@50Hz(I)
Seco
nd
ary
Volt
age(
mV
)
Primary Current@50Hz(I)
Seco
nd
ary
Volt
age(
mV
)
Rated Current : 300A/0.15VA@50Hz
F(I)
[%]&
f[˚]
@25
C
Rated Current : 500A/0.31VA@50Hz
F(I)
[%]&
f[˚]
@25
C
Rated Current : 600A/0.08VA@50Hz
F(I)
[%]&
f[˚]
@25
C
f(Hz)
Seco
nd
ary
Volt
age(
mV
)f(Hz)
Seco
nd
ary
Volt
age(
mV
)
f(Hz)
Seco
nd
ary
Volt
age(
mV
)
-21 105 20 100 15050 120 200
-1
0
1
2
IEC60044-1 P h a s eAmplitude
-21 105 20 100 15050 120 200
-1
0
1
2
IEC60044-1 P h a s eAmplitude
-21 105 20 100 15050 120 200
-1
0
1
2
IEC60044-1 P h a s eAmplitude
5 Ω
5 Ω
2 Ω
LOAD
CONTACTOR
CurrentMonitoringS1
S
2
POWER
BipolarDirectionalZenor Diode
M3 Screw M3 Screw
S2 S1
P2 P1
91
62
57
S1 S2
36
36
2240.5
P2 P1
21 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
SPECIFICATION
ModelJC10F-333(xxx)
Ø10
Amperage Range
Output Voltage
Nominal Phase Angle Error
Nominal Linearity Error
Protection Level
Insulation Category
Operating Condition
Storage Condition
5, 10, 20, 2530, 50, 75
+1.5 ± 1˚
-1 ± 1%
JC16F-333(xxx)
Ø16
70, 100
+1.0 ± 1˚
-1 ± 1%
2.2V0-P
JC24F-333(xxx)
Ø24
5, 10, 30, 50, 70100, 150, 200
+1.0 ± 1˚
-1 ± 1%
JC36S-333(xxx)
Ø36
300, 400,500, 600
+0.5 ± 0.5˚
± 1%
3.0V0-PCATⅢ
-20˚C~+50˚C, ≤85%RH, No condensation, In-house & Any direction installable
-30˚C~+90˚C, ≤85%RH, No condensation
333mV
(F=50/60Hz)
• High accuracy : 1% from 10% to 120% of rated current• Nylon-spring, output-terminal, secure locking hinge, one-touch structure makes easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010-1 certified
APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
HOW TO USE
SPLIT-CORE CURRENT TRANSFORMER
JCXXF-333mV series
• If you impact the core contact surface, internal core material could be damaged.(Ø10, Ø16, Ø24 type)• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side.(Ø36 type)• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts.• Please use only the original output screws. Not recommanded to replace it with anything else.• Customizing output lead wire
JC series of split-core current transformer offers 333mV at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JC series to meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact meter design and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.
vac
2 3
4 5 6
1
P2 P1
METER
S1 S2 M3-Screwdriver
8mm
Terminalcover
CLOSE
Terminalcover
OPEN
50A : 333mVJD150310
JC10F-333
S1 S2E344623
50A : 333mVJD150310
JC10F-333
S1 S2E344623
50A : 333mVJD150310
JC10F-333
S1 S2E344623
100A : 333mVJD150310
JC16F-333
S1 S2E344623
200A : 333mVJD150310
JC24F-333
S1 S2E344623
400A : 333mVJD150310
JC36S-333
S1 S2E344623
22PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
OUTPUT VOLTAGE DATA
APPLICATIONS / DIMENSIONS
JC10F-333
5 10 20 25 30 500 75
Thru-hole Current Io (Arms 50/60Hz)
400mV
333mV
Out
put V
olta
ge E
o (V
ac)
Limiter
Rated Output
JC16F-333
400mV
333mV
Out
put V
olta
ge E
o (V
ac)
1000
Thru-hole Current Io (Arms 50/60Hz)
Limiter
Rated Output
70
JC24F-333
400mV
333mV
Out
put V
olta
ge E
o (V
ac)
10050 700 20015010 305
Thru-hole Current Io (Arms 50/60Hz)
Limiter
Rated Output
JC36S-333
400mV
333mV
Out
put V
olta
ge E
o (V
ac)
4000
Thru-hole Current Io (Arms 50/60Hz)
Limiter
Rated Output
300 500 600
P2 P1
CONTACTOR
CurrentMonitoring
LOAD
POWER
S2 S1
J&D
S2S1
E
D C
B
A
Unit : mm
ModelJC10F-333JC16F-333JC24F-333JC36S-333
A5055
74.591
B38415262
C23
29.54557
D263134
40.5
E14.5192222
Ød10162436
M3 Screw M3 Screw
P2 P1
L K
S2
S1
Φd
23 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
SPECIFICATION
ModelJC10FL-333(xxx)
Ø10
Amperage Range
Output Voltage
Nominal Phase Angle Error
Nominal Linearity Error
Protection Level
Insulation Category
Operating Condition
Storage Condition
5, 10, 20, 2530, 50, 75
+1.5 ± 1˚
-1 ± 1%
JC16FL-333(xxx)
Ø16
70, 100
+1.0 ± 1˚
-1 ± 1%
2.2V0-P
CATⅢ
-20˚C~+50˚C, ≤85%RH, No condensation, In-house & Any direction installable
-30˚C~+90˚C, ≤85%RH, No condensation
333mV
(F=50/60Hz)
• High accuracy : 1% from 10% to 120% of rated current• Nylon-spring, output-terminal, secure locking hinge, one-touch structure makes easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010-1 certified
APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
SPLIT-CORE CURRENT TRANSFORMER
JCXXFL-333mV series
• If you impact the core contact surface, internal core material could be damaged.• Customizing output lead wire
JC series of split-core current transformer offers 333mV at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JC series to meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact meter design and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.
vac
120A : 40mAJD150310
JC16FL
S1 S2E344623
5A : 333mVJD150310
JC10FL-333
S1 S2E344623
70A : 333mVJD150310
JC16FL-333
S1 S2E344623
HOW TO USE 2
3 4
1
P2 P1
24PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
OUTPUT VOLTAGE DATA
APPLICATIONS / DIMENSIONS
JC10FL-333
5 10 20 25 30 500 75
Thru-hole Current Io (Arms 50/60Hz)
400mV
333mV
Out
put V
olta
ge E
o (V
ac)
Limiter
Rated Output
JC16FL-333
400mV
333mV
Out
put V
olta
ge E
o (V
ac)
1000
Thru-hole Current Io (Arms 50/60Hz)
Limiter
Rated Output
70
CONTACTOR
CurrentMonitoring
LOAD
POWER
S2S1
JC16FL-333
JC10FL-33318
.60
29.40
16.20
15.7
021
.90
44.6
0
31.60
18.90
5.40
41.2
0
31.70
40.4
0
23.60
10.5
0
10
11
24.70
14.40
26.70
24.4
015
14
BipolarDirectionalZenor Diode
White wire
(S1)Black wire
(S2)
P1 P2
SPECIFICATION
Accuracy
Output Terminals
System Voltage
Overload withstand
Compliant with
Operating Temperature Range
Relative Humidity
Test Voltage
Frequency Range
Protection Level
Insulation Category
Class 0.5S / 1.0
2 X M3-Screw, with Terminals cover
720V(0.72kV)
1.2 times rated current continuously
IEC/EN61869-2 & IEC61010-1
-20˚C to 55˚C
0-85% non-condensing
3kV for 1minute
50/60Hz
3.0V0-P
CATⅡ or CATⅢ 600VAC
• PC spring, output-terminal, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified
APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
HOW TO USE
SPLIT-CORE CURRENT TRANSFORMER
JSXXF-XXX-333mV series
• If you impact the core surface, internal core material could be damaged.• Customizing output lead wire
JS series of split-core current transformer offers 333mV at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JS series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.
25 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
vac
JS24F-200/333mV
S1 S2
200A : 333mV Lot no:120601IEC60044-1 class 0.5S, 0.033VA F=50/60Hz Umax=720V Ui=3kV
150A : 333mV Lot no:120601IEC60044-1 class 1.0, 0.033VAF=50/60Hz Umax=720V Ui=3kV
JS17F-150/333mV
S1 S2
2 3
4 5 6
1
Terminalcover
OPEN
S1 S2 M3-Screwdriver
8mm
Terminalcover
CLOSE
P2 P1
METER
CURRENT TRANSFORMER RATIOS / DIMENSIONS
26PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
Dimensions
35.8
26.2
P2 P1
64.1
41.1
33.1
S1 S2
17
17
Dimensions
74.5
47
45
S1 S2
24
24
21.1
33.7
P2 P1
M3 Screw M3 Screw
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In
BipolarDirectionalZenor Diode
M3 Screw M3 Screw
S1S2
P1P2
BipolarDirectionalZenor Diode
S1S2
P1P2
How to Order / Model Reference
eg - / J S 1 7 F 00 0 333 mV
Model J S 1 7 F
3 3 3 mVSecondary Voltage333mV
Primary CurrentSelect code from ratio table
How to Order / Model Reference
eg - / J S 2 4 F 00 0 333 mV
Model J S 2 4 F
3 3 3 mVSecondary Voltage333mV
Primary CurrentSelect code from ratio table
Current Transformer Ratios
50 0.05 050100 0.05 100125 0.05 125150 0.05 150
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
333mV Secondary
Current Transformer Ratios
200 0.05 200
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
333mV Secondary
27 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
SPECIFICATION
Accuracy
Output Terminals
System Voltage
Overload withstand
Compliant with
Operating Temperature Range
Relative Humidity
Test Voltage
Frequency Range
Protection Level
Insulation Category
Class 0.5S / 1.0
2 X M3-Screw, with Terminals cover
720V(0.72kV)
1.2 times rated current continuously
IEC/EN61869-2 & IEC61010-1
-20°C to 55°C
0-85% non-condensing
3kV for 1minute
50/60Hz
3.0V0-P
CATⅡ or CATⅢ 600VAC
• PC spring, output-terminal, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified
APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
HOW TO USE
SPLIT-CORE CURRENT TRANSFORMER
JSXXS-XXX-333mV series
• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side.• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts.• Customizing output lead wire
JS series of split-core current transformer offers 333mV at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JS series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.
vac
2 3
4 5 6
1
Terminalcover
OPEN
S1 S2 M3-Screwdriver
8mm
Terminalcover
CLOSE
P2 P1
METER
JS24S-250/333mV
S1 S2
250A : 333mV Lot no:120601IEC60044-1 class 0.5S, 0.033VA F=50/60Hz Umax=720V Ui=3kV
JS36S-500/333mV
S1 S2
500A : 333mV Lot no:120601IEC60044-1 class 0.5S, 0.033VA F=50/60Hz Umax=720V Ui=3kV
200A : 333mV Lot no:120601IEC60044-1 class 0.5S, 0.033VAF=50/60Hz Umax=720V Ui=3kV
JS17S-200/333mV
S1 S2
CURRENT TRANSFORMER RATIOS / DIMENSIONS
28PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
Dimensions
M3 Screw M3 Screw
Dimensions
M3 Screw M3 Screw
Dimensions
M3 Screw M3 Screw
How to Order / Model Reference
eg - / J S 1 7 S 00 0 333 mV
Model J S 1 7 S
3 3 3 mVSecondary Voltage333mV
Primary CurrentSelect code from ratio table
How to Order / Model Reference
eg - / J S 2 4 S 00 0 333 mV
Model J S 2 4 S
3 3 3 mVSecondary Voltage333mV
Primary CurrentSelect code from ratio table
How to Order / Model Reference
eg - / J S 3 6 S 00 0 333 mV
Model J S 3 6 S
3 3 3 mVSecondary Voltage333mV
Primary CurrentSelect code from ratio table
BipolarDirectionalZenor Diode
S1S2
P1P2
BipolarDirectionalZenor Diode
S1S2
P1P2
BipolarDirectionalZenor Diode
S1S2
P1P2
35.8
26.2
P2 P1
64.1
41.1
33.1
S1 S2
17
17
91.4
57
57.1
S1 S2
36
36
21.140.2
P2 P1
74.5
47
45
S1 S2
24
24
21.1
33.7
P2 P1
Current Transformer Ratios
200 0.05 200
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
333mV Secondary
Current Transformer Ratios
250 0.05 250300 0.05 300
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
333mV Secondary
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Current Transformer Ratios
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
333mV Secondary
300 0.05 300400 0.05 400500 0.05 500600 0.05 600
29 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
• PC spring, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified
APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
HOW TO USE
SPLIT-CORE CURRENT TRANSFORMER
JSXXFL-XXX-333mV series
• If you impact the core surface, internal core material could be damaged.• Customizing output lead wire
JS series of split-core current transformer offers 333mV at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JS series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.
SPECIFICATION
Accuracy
System Voltage
Overload withstand
Compliant with
Operating Temperature Range
Relative Humidity
Test Voltage
Frequency Range
Protection Level
Insulation Category
Class 1.0
720V(0.72kV)
1.2 times rated current continuously
IEC/EN61869-2 & IEC61010-1
-20°C to 55°C
0-85% non-condensing
3kV for 1minute
50/60Hz
3.0V0-P
CATⅡ or CATⅢ 600VAC
vac
CURRENT TRANSFORMER RATIOS
APPLICATIONS / DIMENSIONS
30PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
How to Order / Model Reference
eg 1 - / SJ 1 0 F L 00 0 333 mV
Model J S 1 0 F L
3 3 3 mVSecondary Voltage333mV
Primary CurrentSelect code from ratio table
How to Order / Model Reference
eg 1 - / SJ 1 6 F L 00 0 333 mV
Model J S 1 6 F L
3 3 3 mVSecondary Voltage333mV
Primary CurrentSelect code from ratio table
How to Order / Model Reference
eg 1 - / SJ 2 4 F L 00 0 333 mV
Model J S 2 4 F L
3 3 3 mVSecondary Voltage333mV
Primary CurrentSelect code from ratio table
Current Transformer Ratios
5 0.05 00510 0.05 01020 0.05 02025 0.05 02530 0.05 03050 0.05 05075 0.05 075
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
333mV Secondary
Current Transformer Ratios
70 0.05 070100 0.05 100
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
333mV Secondary
Accuracy conforms to IEC 61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Accuracy conforms to IEC 61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Accuracy conforms to IEC 61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Current Transformer Ratios
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
333mV Secondary
5 0.05 00510 0.05 01030 0.05 03050 0.05 05070 0.05 070
100 0.05 100150 0.05 150200 0.05 200
Unit : mm
ModelJS10FLJS16FLJS24FL
A40.54565
B2326
37.5
C23.73045
D26.631.633.7
E14.518.821.1
F150±20150±20200±20
Ød101624
ED
P2
P1
1000
± 5
0
AWG
#22
Relay cable(common)(attached with CT)
Receptacle housing :SLR-02VFPin contact :SSM-21T-P1.4
Housing : 5480-02(Molex.Inc.)Terminal : 5479PBT(Molex.Inc.)
A F
B
C Φd
10FL/16FLAWG#2224FLAWG#18
Plug housing :SLP-02VSocket connector : SSF-21T-P1.4
Whi
te w
ire
(S1)
Blac
k w
ire
(S2)
OPTION
LOAD
S1 S2
CONTACTOR
CurrentMonitoring
POWER
BipolarDirectionalZenor Diode
White wire
(S1)Black wire
(S2)
P1 P2
31 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
• PC spring, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified
APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
HOW TO USE
SPLIT-CORE CURRENT TRANSFORMER
JSXXNL-XXX-333mV series
• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side.• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts.• Customizing output lead wire
JS series of split-core current transformer offers 333mV at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JS series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.
SPECIFICATION
Accuracy
System Voltage
Overload withstand
Compliant with
Operating Temperature Range
Relative Humidity
Test Voltage
Frequency Range
Protection Level
Insulation Category
Class 1.0
720V(0.72kV)
1.2 times rated current continuously
IEC/EN61869-2 & IEC61010-1
-20°C to 55°C
0-85% non-condensing
3kV for 1minute
50/60Hz
3.0V0-P
CATⅡ or CATⅢ 600VAC
vac
CURRENT TRANSFORMER RATIOS
APPLICATIONS / DIMENSIONS
32PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
How to Order / Model Reference
eg 1 - / SJ 1 0 N L 00 0 333 mV
Model J S 1 0 N L
3 3 3 mVSecondary Voltage333mV
Primary CurrentSelect code from ratio table
How to Order / Model Reference
eg 1 - / SJ 1 6 N L 00 0 333 mV
Model J S 1 6 N L
3 3 3 mVSecondary Voltage333mV
Primary CurrentSelect code from ratio table
How to Order / Model Reference
eg 1 - / SJ 2 4 N L 00 0 333 mV
Model J S 2 4 N L
3 3 3 mVSecondary Voltage333mV
Primary CurrentSelect code from ratio table
Current Transformer Ratios
5 0.05 00510 0.05 01020 0.05 02025 0.05 02530 0.05 03050 0.05 05075 0.05 075
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
333mV Secondary
Current Transformer Ratios
70 0.05 070100 0.05 100
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
333mV Secondary
Accuracy conforms to IEC 61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Accuracy conforms to IEC 61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Accuracy conforms to IEC 61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Current Transformer Ratios
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
333mV Secondary
5 0.05 00510 0.05 01030 0.05 03050 0.05 05070 0.05 070
100 0.05 100150 0.05 150200 0.05 200
Unit : mm
ModelJS10NLJS16NLJS24NL
A40.54565
B2326
37.5
C23.73045
D26.631.633.7
E14.518.821.1
F150±20150±20200±20
Ød101624
ED
P2
P1
1000
± 5
0
AWG
#22
Relay cable(common)(attached with CT)
Receptacle housing :SLR-02VFPin contact :SSM-21T-P1.4
Housing : 5480-02(Molex.Inc.)Terminal : 5479PBT(Molex.Inc.)
A F
B
C Φd
10NL/16NLAWG#2224NLAWG#18
Plug housing :SLP-02VSocket connector : SSF-21T-P1.4
Whi
te w
ire
(S1)
Blac
k w
ire
(S2)
OPTION
LOAD
S1 S2
CONTACTOR
CurrentMonitoring
POWER
BipolarDirectionalZenor Diode
White wire
(S1)Black wire
(S2)
P1 P2
• PC spring, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified
APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
SPLIT-CORE CURRENT TRANSFORMER
JSXXSL-XXX-333mV series
• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side.• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts.• Customizing output lead wire
JS series of split-core current transformer offers 333mV at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JS series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.
33 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
SPECIFICATION
Accuracy
System Voltage
Overload withstand
Compliant with
Operating Temperature Range
Relative Humidity
Test Voltage
Frequency Range
Protection Level
Insulation Category
Class 1.0
720V(0.72kV)
1.2 times rated current continuously
IEC/EN61869-2 & IEC61010-1
-20°C to 55°C
0-85% non-condensing
3kV for 1minute
50/60Hz
3.0V0-P
CATⅡ or CATⅢ 600VAC
vac
HOW TO USE
CURRENT TRANSFORMER RATIOS
APPLICATIONS / DIMENSIONS
34PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
How to Order / Model Reference
eg 1 - / SJ 2 4 S L 00 0 333 mV
Model J S 2 4 S L
3 3 3 mVSecondary Voltage333mV
Primary CurrentSelect code from ratio table
How to Order / Model Reference
eg 1 - / SJ 3 6 S L 00 0 333 mV
Model J S 3 6 S L
3 3 3 mVSecondary Voltage333mV
Primary CurrentSelect code from ratio table
Current Transformer Ratios
250 0.05 250300 0.05 300
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
333mV Secondary
Accuracy conforms to IEC 61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In
Accuracy conforms to IEC 61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In
Current Transformer Ratios
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
333mV Secondary
300 0.05 300400 0.05 400500 0.05 500600 0.05 600
Unit : mm
ModelJS24SL
A65
B37.5
C45
D33.7
E21.1
Ød24
JS36SL 82.4 48 57.1 40.2 21.1
F200±20200±20 36
ED
P2
P1
1000
± 5
0
AWG
#22
Relay cable(common)(attached with CT)
Receptacle housing :SLR-02VFPin contact :SSM-21T-P1.4
Housing : 5480-02(Molex.Inc.)Terminal : 5479PBT(Molex.Inc.)
A F
B
C Φd
24SL/36SLAWG#18
Plug housing :SLP-02VSocket connector : SSF-21T-P1.4
Whi
te w
ire
(S1)
Blac
k w
ire
(S2)
OPTION
LOAD
S1 S2
CONTACTOR
CurrentMonitoring
POWER
BipolarDirectionalZenor Diode
White wire
(S1)Black wire
(S2)
P1 P2
35 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
• Steel spring plate, output-terminal, secure locking . hinge, one-touch structure make easy to install to existing equipment such as a power distribution board• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified
APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
REVENUE-GRADESPLIT-CORE CURRENT TRANSFORMER
JM21X-XXX-333mV series
• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side.• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts.• Customizing output lead wire
JM21X series of split-core current transformer offers 333mV at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JM21X series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.
SPECIFICATION
Accuracy
Output Terminals
System Voltage
Overload withstand
Compliant with
Operating Temperature Range
Relative Humidity
Latch/Unlatch
Test Voltage
Frequency Range
Protection Level
Insulation Category
IEC Class 0.5S / ANSI Class 0.6
Terminal Block(2P) - PART NUMBER : LM5.08/02/90 SW(black)
720V(0.72kV)
1.2 times rated current continuously
IEC/EN61869-2, IEEE/ANSI C57.13 & IEC61010-1
-20˚C to 55˚C
0-85% non-condensing
about 100 times
3kV for 1minute
50/60Hz
5.1V0-P
CATⅡ or CATⅢ 600VAC
HOW TO USE
2 3
4 5
14
vac
CURRENT TRANSFORMER RATIOS / DIMENSIONS
36PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In
How to Order / Model Reference
eg - / J M 2 1 X 00 0 333 mV
Model J M 2 1 X
3 3 3 mVSecondary Voltage
333mV
Primary CurrentSelect code from ratio table
Current Transformer Ratios
cl. 0.5S cl. 1 cl. 3
cl. 0.6 cl. 1.2 cl. 2.4
Metering Burden(VA)PrimaryCurrent
(A)Code
333mV Secondary
5 0.001 00515 0.01 01520 0.03 02030 0.05 03050 0.01 05070 0.01 070
100 0.02 100150 0.03 150200 0.04 200250 0.05 250
DIN RAIL MOUNTING Mount the bracket on the rail and install current transformer
PANEL MOUNTING Tighten screws on the hole to mount bracket and install current transformer
ㆍSplit-core CT must be handled with care. A damage caused from the careless handling will not be covered by warranty.
ㆍThe product is designed to meet operating environments dened by the industrial standard IP20.
ㆍBe careful to install the product with the correct polarity.
ㆍDo not install the product if an application exceed the specications of the product.
ㆍRecommended to use the terminals specied by J&D.
Precautions for the Warranty of QualityYEARS
5
W A R R A N T Y
ㆍProtection circuit built in inside of the product for user safety. An additional external protection circuit would be impacted on the feature.
ㆍThe product is designed for measuring sinusoidal 50/60Hz of primary current. Be aware that it is possible to occur the signicant error if it is used to measure non-sinusoidal.
ㆍUse Split-core CT with proper diameter to t the conductor, otherwise it may cause the ratio error and the phase shift.
ㆍBe careful to install Split-core CT without any pollutions on the core surfaces. The pollutions such as moisture, dust and rusty can be caused the error. After removing the pollutions, recommended to use WD-40 or CRC5-56 on the core surfaces.
ㆍCheck whether the secondary leads is connected correctly or not. If the connection is not correctly, the secondary output could be lower than the expected one.
Check Point for the Accurate MeasurementP R O P E R T I E
S
ELECTRICAL
ㆍPlease provide the technical requirements for a technical evaluation.
ㆍThe color of housing is changeable upon the customer’s requirements.
ㆍThe leads can be mounted on the terminals by J&D.
ㆍA protective tailor-made housing is available.
Remarks for the Customized ProductsODM
ON RE Q UEST
INTERNAL CIRCUITDRAWING
28.4
9
95
80.5
4.7 7.2
19.7
2.5
• PANEL MOUNT
51.5
46
7035
35
24.27
• DIN RAIL MOUNT
S2S1
7060
64228
Optional lead wiresBlack & White orBrown & Yellow colors of UL1015#18
2840.3
23.8
14.5
2000 ± 50AWG
#18
8
Relay cable(common)(attached with CT)
Part-NO. : 56002(red)
BipolarDirectionalZenor Diode
S2S1
P2P1
BLACKWIRE
WHITEWIRE
I
• High quality comprehensive measurement• Available in a wide range of transformer ratings• Accuracy up to Class 0.5S
APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels
FEATURES
NOTICE
BENEFITS• Faster installation• Cost effective• Long product life
HOW TO USE
REVENUE-GRADESPLIT-CORE CURRENT TRANSFORMER
JSC-XX-XXXX-333mV series
• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side.• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts.• Customizing output lead wire
JSC series of split-core current transformer offers 333mV at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JSC series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.
37 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
SPECIFICATION
Accuracy
Leads
System Voltage
Overload withstand
Compliant with
Operating Temperature Range
Relative Humidity
Test Voltage
Frequency Range
Protection Level
Insulation Category
Class 0.5S
18AWG, 600VAC
720V(0.72kV)
1.2 times rated current continuously
IEC/EN61869-2 & IEC61010-1
-20˚C to 60˚C
0-85% non-condensing
3kV for 1minute
50/60Hz
3.0V0-P
CATⅡ or CATⅢ 600VAC
2 3
4 5 6
1
600V
AC M
ax. C
ATA
dditi
onal
isol
atio
n m
ust b
e pr
ovid
ed if
use
d at
hig
her v
olta
ges.
P1P2
600V
AC M
ax. C
ATA
dditi
onal
isol
atio
n m
ust b
e pr
ovid
ed if
use
d at
hig
her v
olta
ges.
P1P2
600V
AC M
ax. C
ATA
dditi
onal
isol
atio
n m
ust b
e pr
ovid
ed if
use
d at
hig
her v
olta
ges.
P1P2
vac
JSC-01-250-333mA250A : 333mA Lot no : 120601IEC60044-1 class 0.5, 0.5VA F=50/60Hz Umax=720V Ui=3kV
Source Side S1 : White S2 : Black
E344623
JSC-02-800-333mA800A : 333mA Lot no : 120601IEC60044-1 class 0.5, 0.5VA F=50/60Hz Umax=720V Ui=3kV
Source Side S1 : White S2 : Black
E344623
JSC-03-1600-333mA1600A : 333mA Lot no : 120601IEC60044-1 class 0.5, 0.5VA F=50/60Hz Umax=720V Ui=3kV
Source Side S1 : White S2 : Black
E344623
CURRENT TRANSFORMER RATIOS / DIMENSIONS
38PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Current Transformer Ratios
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
333mV Secondary
250 0.05 0250400 0.05 0400
Dimensions
3929
94
Dimensions Dimensions
933822
32
92
P1
P23929
124
196
141
22
62
124
P1
P2
3929
124
128
124
62
P1
P2
7322
How to Order / Model Reference
eg - - / J S C 0 1 0 00 0 333 mV
Model J S C - 0 1
3 3 3 mVSecondary Voltage333mV
Primary CurrentSelect code from ratio table
BipolarDirectionalZenor Diode
(S2)Black wire
(S1)White wireP1
P2
BipolarDirectionalZenor Diode
(S2)Black wire
(S1)White wireP1
P2
BipolarDirectionalZenor Diode
(S2)Black wire
(S1)White wireP1
P2
Current Transformer Ratios
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
333mV Secondary
400 0.05 0400600 0.05 0600800 0.05 0800
1000 0.05 10001200 0.05 1200
How to Order / Model Reference
eg - - / J S C 0 2 0 00 0 333 mV
Model J S C - 0 2
3 3 3 mVSecondary Voltage333mV
Primary CurrentSelect code from ratio table
Current Transformer Ratios
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
333mV Secondary
800 0.05 08001000 0.05 10001200 0.05 12001600 0.05 16002000 0.05 20002400 0.05 2400
How to Order / Model Reference
eg - - / J S C 0 3 0 00 0 333 mV
Model J S C - 0 3
3 3 3 mVSecondary Voltage333mV
Primary CurrentSelect code from ratio table
39 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
• High quality comprehensive measurement• Available in a wide range of transformer ratings• Accuracy up to Class 0.5S
APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels
FEATURES
NOTICE
BENEFITS• Faster installation• Cost effective• Long product life
HOW TO USE
REVENUE-GRADESPLIT-CORE CURRENT TRANSFORMER
JSC-XXN-XXXX-333mV series
• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side.• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts.• Customizing output lead wire
JSC series of split-core current transformer offers 333mV at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JSC series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.
SPECIFICATION
Accuracy
Leads
System Voltage
Overload withstand
Compliant with
Operating Temperature Range
Relative Humidity
Test Voltage
Frequency Range
Protection Level
Insulation Category
Class 0.5S
18AWG, 600VAC
720V(0.72kV)
1.2 times rated current continuously
IEC/EN61869-2 & IEC61010-1
-20˚C to 60˚C
0-85% non-condensing
3kV for 1minute
50/60Hz
3.0V0-P
CATⅡ or CATⅢ 600VAC
2 3
4 5 6
1
600V
AC M
ax. C
ATA
dditi
onal
isol
atio
n m
ust b
e pr
ovid
ed if
use
d at
hig
her v
olta
ges.
P1P2
600V
AC M
ax. C
ATA
dditi
onal
isol
atio
n m
ust b
e pr
ovid
ed if
use
d at
hig
her v
olta
ges.
P1P2
600V
AC M
ax. C
ATA
dditi
onal
isol
atio
n m
ust b
e pr
ovid
ed if
use
d at
hig
her v
olta
ges.
P1P2
vac
JSC-01N-250-333mA250A : 333mA Lot no : 120601IEC60044-1 class 0.5, 0.5VA F=50/60Hz Umax=720V Ui=3kV
Source Side S1 : White S2 : Black
E344623
JSC-02N-800-333mA800A : 333mA Lot no : 120601IEC60044-1 class 0.5, 0.5VA F=50/60Hz Umax=720V Ui=3kV
Source Side S1 : White S2 : Black
E344623
JSC-03N-1600-333mA1600A : 333mA Lot no : 120601IEC60044-1 class 0.5, 0.5VA F=50/60Hz Umax=720V Ui=3kV
Source Side S1 : White S2 : Black
E344623
40PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
CURRENT TRANSFORMER RATIOS / DIMENSIONS
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Current Transformer Ratios
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
333mV Secondary
250 0.05 0250400 0.05 0400
Dimensions
3929
94
Dimensions Dimensions
933822
32
92
P1
P23929
124
196
141
22
62
124
P1
P2
3929
124
128
124
62
P1
P2
7322
BipolarDirectionalZenor Diode
(S2)Black wire
(S1)White wireP1
P2
BipolarDirectionalZenor Diode
(S2)Black wire
(S1)White wireP1
P2
BipolarDirectionalZenor Diode
(S2)Black wire
(S1)White wireP1
P2
Current Transformer Ratios
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
333mV Secondary
400 0.05 0400600 0.05 0600800 0.05 0800
1000 0.05 10001200 0.05 1200
Current Transformer Ratios
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
333mV Secondary
800 0.05 08001000 0.05 10001200 0.05 12001600 0.05 16002000 0.05 20002400 0.05 2400
How to Order / Model Reference
eg - - / J S C 0 1 N 0 00 0 333 mV
M J S C - 0 1 N
3 3 3 mVSecondary Voltage333mV
Primary CurrentSelect code from ratio table
How to Order / Model Reference
eg - - / J S C 0 2 N 0 00 0 333 mV
M J S C - 0 2 N
3 3 3 mVSecondary Voltage333mV
Primary CurrentSelect code from ratio table
How to Order / Model Reference
eg - - / J S C 0 3 N 0 00 0 333 mV
M J S C - 0 3 N
3 3 3 mVSecondary Voltage333mV
Primary CurrentSelect code from ratio table
SPECIFICATION
Accuracy
Output Terminals
System Voltage
Overload withstand
Compliant with
Operating Temperature Range
Relative Humidity
Test Voltage
Frequency Range
Protection Level
Insulation Category
Class 1.0
2 X M3-Screw, with Terminals cover
720V(0.72kV)
1.2 times rated current continuously
IEC/EN61869-2 & IEC61010-1
-20˚C to 55˚C
0-85% non-condensing
3kV for 1minute
50/60Hz
3.0V0-P
CATⅡ or CATⅢ 600VAC
41 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
• Nylon-spring, output-terminal, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified
APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
HOW TO USE
SPLIT-CORE CURRENT TRANSFORMER
JCXXF-XXX-100mA series
• If you impact the core contact surface, internal core material could be damaged.• Please use only the original output screws. Not recommanded to replace it with anything else.• Customizing out put lead wire
JC series of split-core current transformer offers 100mA at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JC series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.
2 3
4 5 6
1
P2 P1
METER
S1 S2 M3-Screwdriver
8mm
Terminalcover
CLOSE
Terminalcover
OPEN
JD120601
S1 S2
JC24F125A :100mA
200A : 100mA Lot no:120601IEC60044-1 class 0.5S, 0.01VAF=50/60Hz Umax=720V Ui=3kV
JS17S-200/100mA
S1 S2
JD120601
S1 S2
JC16F125A :100mA
42PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
CURRENT TRANSFORMER RATIOS / DIMENSIONS
Current Transformer Ratios
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
100mA Secondary
Dimensions
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In
Dimensions
31
19
P2 P1
55
41
29.5
S1 S2
1674
.5
5245
S1 S2
24
22
34
P2 P1
How to Order / Model Reference
eg - / J C 1 6 F 00 0 001 mA
Model J C 1 6 F
1 0 0 mASecondary Current100mA
Primary CurrentSelect code from ratio table
How to Order / Model Reference
eg - / J C 2 4 F 00 0 001 mA
Model J C 2 4 F
1 0 0 mASecondary Current100mA
Primary CurrentSelect code from ratio table
BipolarDirectionalZenor Diode
M3 Screw M3 Screw
S2 S1
P2 P1
BipolarDirectionalZenor Diode
M3 Screw M3 Screw
S2 S1
P2 P1
50 0.05 050100 0.05 100125 0.05 125
Current Transformer Ratios
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
100mA Secondary
125 0.05 125200 0.05 200
43 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
SPECIFICATION
Accuracy
Output Terminals
System Voltage
Overload withstand
Compliant with
Operating Temperature Range
Relative Humidity
Test Voltage
Frequency Range
Protection Level
Insulation Category
Class 1.0
2 X M3-Screw, with Terminals cover
720V(0.72kV)
1.2 times rated current continuously
IEC/EN61869-2 & IEC61010-1
-20˚C to 55˚C
0-85% non-condensing
3kV for 1minute
50/60Hz
3.0V0-P
CATⅡ or CATⅢ 600VAC
• Nylon-spring, output-terminal, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified
APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
HOW TO USE
SPLIT-CORE CURRENT TRANSFORMER
JCXXN-XXX-100mA series
• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side.• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any parts.• Please use only the original output screws. Not recommanded to replace it with anything else.• Customizing out put lead wire
JC series of split-core current transformer offers 100mA at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JC series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.
2 3
4 5 6
1
P2 P1
METER
S1 S2 M3-Screwdriver
8mm
Terminalcover
CLOSE
Terminalcover
OPEN
JD120601
S1 S2
JC24N125A :100mA
200A : 100mA Lot no:120601IEC60044-1 class 0.5S, 0.01VAF=50/60Hz Umax=720V Ui=3kV
JS17S-200/100mA
S1 S2
JD120601
S1 S2
JC16N125A :100mA
44PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
CURRENT TRANSFORMER RATIOS / DIMENSIONS
Current Transformer Ratios
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
100mA Secondary
Dimensions
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In
Dimensions
31
19
P2 P1
55
41
29.5
S1 S2
1674
.5
5245
S1 S2
24
22
34
P2 P1
How to Order / Model Reference
eg - / J C 1 6 N 00 0 001 mA
Model J C 1 6 N
1 0 0 mASecondary Current100mA
Primary CurrentSelect code from ratio table
How to Order / Model Reference
eg - / J C 2 4 N 00 0 001 mA
Model J C 2 4 N
1 0 0 mASecondary Current100mA
Primary CurrentSelect code from ratio table
BipolarDirectionalZenor Diode
M3 Screw M3 Screw
S2 S1
P2 P1
BipolarDirectionalZenor Diode
M3 Screw M3 Screw
S2 S1
P2 P1
50 0.05 050100 0.05 100125 0.05 125
Current Transformer Ratios
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
100mA Secondary
125 0.05 125200 0.05 200
45 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
SPECIFICATION
Accuracy
Output Terminals
System Voltage
Overload withstand
Compliant with
Operating Temperature Range
Relative Humidity
Test Voltage
Frequency Range
Protection Level
Insulation Category
Class 0.5S / 1.0
2 X M3-Screw, with Terminals cover
720V(0.72kV)
1.2 times rated current continuously
IEC/EN61869-2 & IEC61010-1
-20˚C to 55˚C
0-85% non-condensing
3kV for 1minute
50/60Hz
3.0V0-P
CATⅡ or CATⅢ 600VAC
• PC spring, output-terminal, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified
APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
HOW TO USE
SPLIT-CORE CURRENT TRANSFORMER
JSXXF-XXX-100mA series
• If you impact the core surface, internal core material could be damaged.• Customizing output lead wire
JS series of split-core current transformer offers 100mA at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JS series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.
2 3
4 5 6
1
P2 P1
METER
S1 S2 M3-Screwdriver
8mm
Terminalcover
CLOSE
Terminalcover
OPEN
JS24F-200/100mA
S1 S2
200A : 100mA Lot no:120601IEC60044-1 class 0.5S, 0.01VA F=50/60Hz Umax=720V Ui=3kV
150A : 100mA Lot no:120601IEC60044-1 class 0.5S, 0.01VAF=50/60Hz Umax=720V Ui=3kV
JS17F-150/100mA
S1 S2
CURRENT TRANSFORMER RATIOS / DIMENSIONS
46PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In
How to Order / Model Reference
eg - / J S 1 7 F 00 0 001 mA
Model J S 1 7 F
1 0 0 mASecondary Current
100mA
Primary CurrentSelect code from ratio table
How to Order / Model Reference
eg - / J S 2 4 F 00 0 001 mA
Model J S 2 4 F
1 0 0 mASecondary Current
100mA
Primary CurrentSelect code from ratio table
Current Transformer Ratios
50 0.05 050100 0.05 100125 0.05 125150 0.05 150
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
100mA Secondary
Current Transformer Ratios
200 0.05 200
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
100mA Secondary
Dimensions Dimensions
35.8
26.2
P2 P1
64.1
41.1
33.1
S1 S2
17
17
BipolarDirectionalZenor Diode
M3 Screw M3 Screw
S2 S1
P2 P1
74.5
47
45
S1 S2
24
24
21.1
33.7
P2 P1
BipolarDirectionalZenor Diode
M3 Screw M3 Screw
S2 S1
P2 P1
47 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
SPECIFICATION
Accuracy
Output Terminals
System Voltage
Overload withstand
Compliant with
Operating Temperature Range
Relative Humidity
Test Voltage
Frequency Range
Protection Level
Insulation Category
Class 0.5S
2 X M3-Screw, with Terminals cover
720V(0.72kV)
1.2 times rated current continuously
IEC61869-2 & IEC61010-1
-20˚C to 55˚C
0-85% non-condensing
3kV for 1minute
50/60Hz
3.0V0-P
CATⅡ or CATⅢ 600VAC
• PC spring, output-terminal, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified
APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
HOW TO USE
SPLIT-CORE CURRENT TRANSFORMER
JSXXS-XXX-100mA series
• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side.• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any parts.• Customizing output lead wire
JS series of split-core current transformer offers 100mA at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JS series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.
2 3
4 5 6
1
P2 P1
METER
S1 S2 M3-Screwdriver
8mm
Terminalcover
CLOSE
Terminalcover
OPEN
JS24S-250/100mA
S1 S2
250A : 100mA Lot no:120601IEC60044-1 class 0.5S, 0.01VA F=50/60Hz Umax=720V Ui=3kV
JS36S-500/100mA
S1 S2
500A : 100mA Lot no:120601IEC60044-1 class 0.5S, 0.01VA F=50/60Hz Umax=720V Ui=3kV
200A : 100mA Lot no:120601IEC60044-1 class 0.5S, 0.01VAF=50/60Hz Umax=720V Ui=3kV
JS17S-200/100mA
S1 S2
CURRENT TRANSFORMER RATIOS / DIMENSIONS
48PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
Current Transformer Ratios
200 0.05 200
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
100mA Secondary
Current Transformer Ratios
250 0.05 250300 0.05 300
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
100mA Secondary
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Current Transformer Ratios
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
100mA Secondary
300 0.05 300400 0.05 400500 0.05 500600 0.05 600
Dimensions Dimensions Dimensions
35.8
26.2
P2 P1
64.1
41.1
33.1
S1 S2
17
17
91.4
57
57.1
S1 S2
36
36
21.140.2
P2 P1
74.5
47
45
S1 S2
24
24
21.1
33.7
P2 P1
How to Order / Model Reference
eg - / J S 1 7 S 00 0 001 mA
Model J S 1 7 S
1 0 0 mASecondary Current
100mA
Primary CurrentSelect code from ratio table
How to Order / Model Reference
eg - / J S 2 4 S 00 0 001 mA
Model J S 2 4 S
1 0 0 mASecondary Current
100mA
Primary CurrentSelect code from ratio table
How to Order / Model Reference
eg - / J S 3 6 S 00 0 001 mA
Model J S 3 6 S
1 0 0 mASecondary Current
100mA
Primary CurrentSelect code from ratio table
BipolarDirectionalZenor Diode
M3 Screw M3 Screw
S2 S1
P2 P1
BipolarDirectionalZenor Diode
M3 Screw M3 Screw
S2 S1
P2 P1
BipolarDirectionalZenor Diode
M3 Screw M3 Screw
S2 S1
P2 P1
49 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
SPECIFICATION
Accuracy
System Voltage
Overload withstand
Compliant with
Operating Temperature Range
Relative Humidity
Test Voltage
Frequency Range
Protection Level
Insulation Category
Class 1.0
720V(0.72kV)
1.2 times rated current continuously
IEC/EN61869-2 & IEC61010-1
-20˚C to 55˚C
0-85% non-condensing
3kV for 1minute
50/60Hz
3.0V0-P
CATⅡ or CATⅢ 600VAC
• PC spring, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified
APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
HOW TO USE
SPLIT-CORE CURRENT TRANSFORMER
JSXXFL-XXX-100mA series
• If you impact the core contact surface, internal core material could be damaged.• Customizing output lead wire
JS series of split-core current transformer offers 100mA at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JS series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.
CURRENT TRANSFORMER RATIOS
APPLICATIONS / DIMENSIONS
50PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
How to Order / Model Reference
eg 1 - / SJ 1 6 F L 00 0 001 mA
Model J S 1 6 F L
1 0 0 mASecondary Current100mA
Primary CurrentSelect code from ratio table
How to Order / Model Reference
eg 1 - / SJ 2 4 F L 00 0 001 mA
Model J S 2 4 F L
1 0 0 mASecondary Current100mA
Primary CurrentSelect code from ratio table
Current Transformer Ratios
50 0.05 050100 0.05 100
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
100mA Secondary
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In
Current Transformer Ratios
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
100mA Secondary
200 0.05 200
Unit : mm
ModelJS16FLJS24FL
A4565
B26
37.5
C3045
D31.633.7
E18.821.1
F150±20200±20
Ød1624
BipolarDirectionalZenor Diode
White wire
(S1)Black wire
(S2)
P1 P2
ED
P2
P1
1000
± 5
0
AWG
#22
Relay cable(common)(attached with CT)
Receptacle housing :SLR-02VFPin contact :SSM-21T-P1.4
Housing : 5480-02(Molex.Inc.)Terminal : 5479PBT(Molex.Inc.)
A F
B
C Φd
16FLAWG#2224FLAWG#18
Plug housing :SLP-02VSocket connector : SSF-21T-P1.4
Whi
te w
ire
(S1)
Blac
k w
ire
(S2)
OPTION
LOAD
S1 S2
CONTACTOR
CurrentMonitoring
POWER
51 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
• PC spring, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified
APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
HOW TO USE
SPLIT-CORE CURRENT TRANSFORMER
JSXXNL-XXX-100mA series
• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts.• Customizing output lead wire
JS series of split-core current transformer offers 100mA at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JS series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.
SPECIFICATION
Accuracy
System Voltage
Overload withstand
Compliant with
Operating Temperature Range
Relative Humidity
Test Voltage
Frequency Range
Protection Level
Insulation Category
Class 1.0
720V(0.72kV)
1.2 times rated current continuously
IEC/EN61869-2 & IEC61010-1
-20°C to 55°C
0-85% non-condensing
3kV for 1minute
50/60Hz
3.0V0-P
CATⅡ or CATⅢ 600VAC
CURRENT TRANSFORMER RATIOS
APPLICATIONS / DIMENSIONS
52PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
How to Order / Model Reference
eg 1 - / SJ 1 6 N L 00 0 001 mA
Model J S 1 6 N L
1 0 0 mASecondary Current100mA
Primary CurrentSelect code from ratio table
How to Order / Model Reference
eg 1 - / SJ 2 4 N L 00 0 001 mA
Model J S 2 4 N L
1 0 0 mASecondary Current100mA
Primary CurrentSelect code from ratio table
Current Transformer Ratios
50 0.05 050100 0.05 100
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
100mA Secondary
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In
Current Transformer Ratios
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
100mA Secondary
200 0.05 200
Unit : mm
ModelJS16NLJS24NL
A4565
B26
37.5
C3045
D31.633.7
E18.821.1
F150±20200±20
Ød1624
BipolarDirectionalZenor Diode
White wire
(S1)Black wire
(S2)
P1 P2
ED
P2
P1
1000
± 5
0
AWG
#22
Relay cable(common)(attached with CT)
Receptacle housing :SLR-02VFPin contact :SSM-21T-P1.4
Housing : 5480-02(Molex.Inc.)Terminal : 5479PBT(Molex.Inc.)
A F
B
C Φd
16NLAWG#2224NLAWG#18
Plug housing :SLP-02VSocket connector : SSF-21T-P1.4
Whi
te w
ire
(S1)
Blac
k w
ire
(S2)
OPTION
LOAD
S1 S2
CONTACTOR
CurrentMonitoring
POWER
• PC spring, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified
APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
SPLIT-CORE CURRENT TRANSFORMER
JSXXSL-XXX-100mA series
• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts.• Customizing output lead wire
JS series of split-core current transformer offers 100mA at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JS series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.
53 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
SPECIFICATION
Accuracy
System Voltage
Overload withstand
Compliant with
Operating Temperature Range
Relative Humidity
Test Voltage
Frequency Range
Protection Level
Insulation Category
Class 1.0
720V(0.72kV)
1.2 times rated current continuously
IEC/EN61869-2 & IEC61010-1
-20°C to 55°C
0-85% non-condensing
3kV for 1minute
50/60Hz
3.0V0-P
CATⅡ or CATⅢ 600VAC
HOW TO USE
CURRENT TRANSFORMER RATIOS
APPLICATIONS / DIMENSIONS
54PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
How to Order / Model Reference
eg 1 - / SJ 2 4 S L 00 0 001 mA
Model J S 2 4 S L
1 0 0 mASecondary Current100mA
Primary CurrentSelect code from ratio table
How to Order / Model Reference
eg 1 - / SJ 3 6 S L 00 0 001 mA
Model J S 3 6 S L
1 0 0 mASecondary Current100mA
Primary CurrentSelect code from ratio table
Current Transformer Ratios
250 0.05 250300 0.05 300
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
100mA Secondary
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In
Current Transformer Ratios
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
100mA Secondary
300 0.05 300400 0.05 400500 0.05 500600 0.05 600
Unit : mm
ModelJS24SL
A65
B37.5
C45
D33.7
E21.1
Ød24
JS36SL 82.4 48 57.1 40.2 21.1
F200±20200±20 36
BipolarDirectionalZenor Diode
White wire
(S1)Black wire
(S2)
P1 P2
ED
P2
P1
1000
± 5
0
AWG
#22
Relay cable(common)(attached with CT)
Receptacle housing :SLR-02VFPin contact :SSM-21T-P1.4
Housing : 5480-02(Molex.Inc.)Terminal : 5479PBT(Molex.Inc.)
A F
B
C Φd
24SL/36SLAWG#18
Plug housing :SLP-02VSocket connector : SSF-21T-P1.4
Whi
te w
ire
(S1)
Blac
k w
ire
(S2)
OPTION
LOAD
S1 S2
CONTACTOR
CurrentMonitoring
POWER
55 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
• Steel spring plate, output-terminal, secure locking . hinge, one-touch structure easily to install to existing equipment such as a power distribution board• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified
APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
REVENUE-GRADESPLIT-CORE CURRENT TRANSFORMER
JM21X-XXX-100mA series
• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts.• Customizing output lead wire
JM21X series of split-core current transformer offers 100mA at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JM21X series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.
SPECIFICATION
Accuracy
Output Terminals
System Voltage
Overload withstand
Compliant with
Operating Temperature Range
Relative Humidity
Latch/Unlatch
Test Voltage
Frequency Range
Protection Level
Insulation Category
IEC Class 0.5S / ANSI Class 0.6
Terminal Block(2P) - PART NUMBER : LM5.08/02/90 SW(black)
720V(0.72kV)
1.2 times rated current continuously
IEC/EN61869-2, IEEE/ANSI C57.13 & IEC61010-1
-20˚C to 55˚C
0-85% non-condensing
about 100 times
3kV for 1minute
50/60Hz
5.1V0-P
CATⅡ or CATⅢ 600VAC
HOW TO USE
2 3
4 5
14
S2
S1
CURRENT TRANSFORMER RATIOS / DIMENSIONS
56PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In
How to Order / Model Reference
eg - / J M 2 1 X 00 0 001 mA
Model J M 2 1 X
1 0 0 mASecondary Current
100mA
Primary CurrentSelect code from ratio table
DIN RAIL MOUNTING Mount the bracket on the rail and install current transformer
PANEL MOUNTING Tighten screws on the hole to mount bracket and install current transformer
ㆍSplit-core CT must be handled with care. A damage caused from the careless handling will not be covered by warranty.
ㆍThe product is designed to meet operating environments dened by the industrial standard IP20.
ㆍBe careful to install the product with the correct polarity.
ㆍDo not install the product if an application exceed the specications of the product.
ㆍRecommended to use the terminals specied by J&D.
Precautions for the Warranty of QualityYEARS
5
W A R R A N T Y
ㆍProtection circuit built in inside of the product for user safety. An additional external protection circuit would be impacted on the feature.
ㆍThe product is designed for measuring sinusoidal 50/60Hz of primary current. Be aware that it is possible to occur the signicant error if it is used to measure non-sinusoidal.
ㆍUse Split-core CT with proper diameter to t the conductor, otherwise it may cause the ratio error and the phase shift.
ㆍBe careful to install Split-core CT without any pollutions on the core surfaces. The pollutions such as moisture, dust and rusty can be caused the error. After removing the pollutions, recommended to use WD-40 or CRC5-56 on the core surfaces.
ㆍCheck whether the secondary leads is connected correctly or not. If the connection is not correctly, the secondary output could be lower than the expected one.
Check Point for the Accurate MeasurementP R O P E R T I E S
ELECTRICAL
ㆍPlease provide the technical requirements for a technical evaluation.
ㆍThe color of housing is changeable upon the customer’s requirements.
ㆍThe leads can be mounted on the terminals by J&D.
ㆍA protective tailor-made housing is available.
Remarks for the Customized ProductsODM
ON RE Q U EST
BipolarDirectionalZenor Diode
BLACKWIRE
WHITEWIRE
S2S1
P2P1
INTERNAL CIRCUITDRAWING
28.4
9
95
80.5
4.7 7.2
19.7
2.5
• PANEL MOUNT
51.5
46
7035
35
24.27
• DIN RAIL MOUNT
S2S1
7060
64228
Optional lead wiresBlack & White orBrown & Yellow colors of UL1015#18
2840.3
23.8
14.5
2000 ± 50AWG
#18
8
Relay cable(common)(attached with CT)
Part-NO. : 56002(red)
Current Transformer Ratios
cl. 0.5S cl. 1 cl. 3
cl. 0.6 cl. 1.2 cl. 2.4
Metering Burden(VA)PrimaryCurrent
(A)Code
100mA Secondary
50 0.01 05070 0.01 070
100 0.01 100125 0.01 125150 0.01
0.020.020.050.050.05 150
200 0.05 200250 0.05 250
• High quality comprehensive measurement• Available in a wide range of transformer ratings• Accuracy up to Class 0.5S
APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels
FEATURES
NOTICE
BENEFITS• Faster installation• Cost effective• Long product life
HOW TO USE
REVENUE-GRADESPLIT-CORE CURRENT TRANSFORMER
JSC-XX-XXXX-100mA series
• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts.• Customizing output lead wire
JSC series of split-core current transformer offers 100mA at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JSC series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.
57 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
SPECIFICATION
Accuracy
Leads
System Voltage
Overload withstand
Compliant with
Operating Temperature Range
Relative Humidity
Test Voltage
Frequency Range
Protection Level
Insulation Category
Class 0.5S
18AWG, 600VAC
720V(0.72kV)
1.2 times rated current continuously
IEC/EN61869-2 & IEC61010-1
-20˚C to 60˚C
0-90% non-condensing
3kV for 1minute
50/60Hz
3.0V0-P
CATⅡ or CATⅢ 600VAC
2 3
4 5 6
1
JSC-01-250-100mA250A : 100mA Lot no : 120601IEC60044-1 class 0.5, 0.5VA F=50/60Hz Umax=720V Ui=3kV
Source Side S1 : White S2 : Black
E344623
JSC-02-800-100mA800A : 100mA Lot no : 120601IEC60044-1 class 0.5, 0.5VA F=50/60Hz Umax=720V Ui=3kV
Source Side S1 : White S2 : Black
E344623
JSC-03-1600-100mA1600A : 100mA Lot no : 120601IEC60044-1 class 0.5, 0.5VA F=50/60Hz Umax=720V Ui=3kV
Source Side S1 : White S2 : Black
E344623
600V
AC M
ax. C
ATA
dditi
onal
isol
atio
n m
ust b
e pr
ovid
ed if
use
d at
hig
her v
olta
ges.
P1P2
600V
AC M
ax. C
ATA
dditi
onal
isol
atio
n m
ust b
e pr
ovid
ed if
use
d at
hig
her v
olta
ges.
P1P2
600V
AC M
ax. C
ATA
dditi
onal
isol
atio
n m
ust b
e pr
ovid
ed if
use
d at
hig
her v
olta
ges.
P1P2
CURRENT TRANSFORMER RATIOS / DIMENSIONS
58PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Current Transformer Ratios
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
100mA Secondary
250 0.05 0250400 0.05 0400
Current Transformer Ratios
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
100mA Secondary
400 0.05 0400600 0.05 0600800 0.05 0800
1000 0.05 10001200 0.05 1200
Current Transformer Ratios
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
100mA Secondary
800 0.05 08001000 0.05 10001200 0.05 12001600 0.05 16002000 0.05 20002400 0.05 2400
Dimensions
3929
94
Dimensions Dimensions
933822
32
92
P1
P23929
124
196
141
22
62
124
P1
P2
3929
124
128
124
62
P1
P2
7322
How to Order / Model Reference
eg - - / J S C 0 1 0 00 0 001 mA
Model J S C - 0 1
1 0 0 mASecondary Current
100mA
Primary CurrentSelect code from ratio table
How to Order / Model Reference
eg - - / J S C 0 2 0 00 0 001 mA
Model J S C - 0 2
1 0 0 mASecondary Current
100mA
Primary CurrentSelect code from ratio table
How to Order / Model Reference
eg - - / J S C 0 3 0 00 0 001 mA
Model J S C - 0 3
1 0 0 mASecondary Current
100mA
Primary CurrentSelect code from ratio table
BipolarDirectionalZenor Diode
(S2)Black wire
(S1)White wireP1
P2
BipolarDirectionalZenor Diode
(S2)Black wire
(S1)White wireP1
P2
BipolarDirectionalZenor Diode
(S2)Black wire
(S1)White wireP1
P2
59 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
• High quality comprehensive measurement• Available in a wide range of transformer ratings• Accuracy up to Class 0.5S
APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels
FEATURES
NOTICE
BENEFITS• Faster installation• Cost effective• Long product life
HOW TO USE
REVENUE-GRADESPLIT-CORE CURRENT TRANSFORMER
JSC-XXN-XXXX-100mA series
• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts.• Customizing output lead wire
JSC series of split-core current transformer offers 100mA at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JSC series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.
SPECIFICATION
Accuracy
Leads
System Voltage
Overload withstand
Compliant with
Operating Temperature Range
Relative Humidity
Test Voltage
Frequency Range
Protection Level
Insulation Category
Class 0.5S
18AWG, 600VAC
720V(0.72kV)
1.2 times rated current continuously
IEC/EN61869-2 & IEC61010-1
-20˚C to 60˚C
0-90% non-condensing
3kV for 1minute
50/60Hz
3.0V0-P
CATⅡ or CATⅢ 600VAC
2 3
4 5 6
1
JSC-01N-250-100mA250A : 100mA Lot no : 120601IEC60044-1 class 0.5, 0.5VA F=50/60Hz Umax=720V Ui=3kV
Source Side S1 : White S2 : Black
E344623
JSC-02N-800-100mA800A : 100mA Lot no : 120601IEC60044-1 class 0.5, 0.5VA F=50/60Hz Umax=720V Ui=3kV
Source Side S1 : White S2 : Black
E344623
JSC-03N-1600-100mA1600A : 100mA Lot no : 120601IEC60044-1 class 0.5, 0.5VA F=50/60Hz Umax=720V Ui=3kV
Source Side S1 : White S2 : Black
E344623
600V
AC M
ax. C
ATA
dditi
onal
isol
atio
n m
ust b
e pr
ovid
ed if
use
d at
hig
her v
olta
ges.
P1P2
600V
AC M
ax. C
ATA
dditi
onal
isol
atio
n m
ust b
e pr
ovid
ed if
use
d at
hig
her v
olta
ges.
P1P2
600V
AC M
ax. C
ATA
dditi
onal
isol
atio
n m
ust b
e pr
ovid
ed if
use
d at
hig
her v
olta
ges.
P1P2
60PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
CURRENT TRANSFORMER RATIOS / DIMENSIONS
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Current Transformer Ratios
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
100mA Secondary
250 0.05 0250400 0.05 0400
Current Transformer Ratios
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
100mA Secondary
400 0.05 0400600 0.05 0600800 0.05 0800
1000 0.05 10001200 0.05 1200
Current Transformer Ratios
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
100mA Secondary
800 0.05 08001000 0.05 10001200 0.05 12001600 0.05 16002000 0.05 20002400 0.05 2400
Dimensions
3929
94
Dimensions Dimensions
933822
32
92
P1
P23929
124
196
141
22
62
124
P1
P2
3929
124
128
124
62
P1
P2
7322
How to Order / Model Reference
eg - - / J S C 0 1 N 0 00 0 001 mA
M J S C - 0 1 N
1 0 0 mASecondary Current
100mA
Primary CurrentSelect code from ratio table
How to Order / Model Reference
eg - - / J S C 0 2 N 0 00 0 001 mA
M J S C - 0 2 N
1 0 0 mASecondary Current
100mA
Primary CurrentSelect code from ratio table
How to Order / Model Reference
eg - - / J S C 0 3 N 0 00 0 001 mA
M J S C - 0 3 N
1 0 0 mASecondary Current
100mA
Primary CurrentSelect code from ratio table
BipolarDirectionalZenor Diode
(S2)Black wire
(S1)White wireP1
P2
BipolarDirectionalZenor Diode
(S2)Black wire
(S1)White wireP1
P2
BipolarDirectionalZenor Diode
(S2)Black wire
(S1)White wireP1
P2
SPECIFICATION
Accuracy
Output Terminals
System Voltage
Overload withstand
Compliant with
Operating Temperature Range
Relative Humidity
Test Voltage
Frequency Range
Protection Level
Insulation Category
Class 0.5S / 1.0 / 3.0
2 X M3-Screw, with Terminals cover
720V(0.72kV)
1.2 times rated current continuously
IEC/EN61869-2 & IEC61010-1
-20˚C to 55˚C
0-85% non-condensing
3kV for 1minute
50/60Hz
Bipolar 6.5Vp
CATⅡ or CATⅢ 600VAC
61 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
• PC spring, output-terminal, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified
APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
HOW TO USE
SPLIT-CORE CURRENT TRANSFORMER
JCXXS-XXX-1A series
• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts• Customizing output lead wire
JC series of split-core current transformer offers 1A at secondary from sensed primary current for metering application. It can be used for power meter, distribution system, control panels, switchgear and other equipment. It is designed to install to live power line without disconnection as split-core compact type. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.
2 3
4 5 6
1
P2 P1
METER
S1 S2 M3-Screwdriver
8mm
Terminalcover
CLOSE
Terminalcover
OPEN
62PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
CURRENT TRANSFORMER RATIOS / DIMENSIONS
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In
Current Transformer Ratios
cl. 0.5S cl. 1 cl. 3
cl. 0.6 cl. 1.2 cl. 2.4
Metering Burden(VA)PrimaryCurrent
(A)Code
1A Secondary
Current Transformer Ratios
cl. 0.5S cl. 1 cl. 3
cl. 0.6 cl. 1.2 cl. 2.4
Metering Burden(VA)PrimaryCurrent
(A)Code
1A Secondary
How to Order / Model Reference
eg - / J C 2 4 S 0 0 0 0 A
Model J C 2 4 S
1 ASecondary Current1A
Primary CurrentSelect code from ratio table
100 1.0 100250 1.0 250
Dimensions
TRIAC
SC
M3 Screw M3 Screw
S2 S1
P2 P1
How to Order / Model Reference
eg - / J C 3 6 S 0 0 0 0 A
Model J C 3 6 S
1 ASecondary Current1A
Primary CurrentSelect code from ratio table
400 0.5 400500 0.5 500600 0.5 600
Dimensions
TRIAC
SC
M3 Screw M3 Screw
S2 S1
P2 P1
91
6257
S1 S2
36
2240.5
P2 P1
74.5
52
45
S1 S2
24
22
34
P2 P1
63 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
SPECIFICATION
Accuracy
Output Terminals
System Voltage
Overload withstand
Compliant with
Operating Temperature Range
Relative Humidity
Test Voltage
Frequency Range
Protection Level
Insulation Category
Class 0.5S / 1.0 / 3.0
2 X M3-Screw, with Terminals cover
720V(0.72kV)
1.2 times rated current continuously
IEC/EN61869-2 & IEC61010-1
-20˚C to 55˚C
0-85% non-condensing
3kV for 1minute
50/60Hz
Bipolar 6.5Vp
CATⅡ or CATⅢ 600VAC
• PC spring, output-terminal, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified
APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General sets• Control panels
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
HOW TO USE
SPLIT-CORE CURRENT TRANSFORMER
JSXXS-XXX-1A series
• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts• Customizing output lead wire
JS series of split-core current transformer offers 1A at secondary from sensed primary current for metering application. It can be used for power meter, distribution system, control panels, switchgear and other equipment. It is designed to install to live power line without disconnection as split-core compact type. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.
2 3
4 5 6
1
P2 P1
METER
S1 S2 M3-Screwdriver
8mm
Terminalcover
CLOSE
Terminalcover
OPEN
JS24S-200/1A
S1 S2
200A : 1A Lot no:120601IEC60044-1 class 1.0, 0.5VA F=50/60Hz Umax=720V Ui=3kV
JS36S-500/1A
S1 S2
500A : 1A Lot no:120601IEC60044-1 class 0.5, 0.5F=50/60Hz Umax=720V Ui=3kV
VA 125A : 1A Lot no:120601IEC60044-1 class 3.0, 1.0VA
F=50/60Hz Umax=720V Ui=3kV
JS17S-125/1A
S1 S2
64PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
CURRENT TRANSFORMER RATIOS / DIMENSIONS
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
How to Order / Model Reference
eg - / J S 1 7 S 0 0 0 0 A
Model J S 1 7 S
1 ASecondary Current1A
Primary CurrentSelect code from ratio table
Dimensions
How to Order / Model Reference
eg - / J S 2 4 S 0 0 0 0 A
Model J S 2 4 S
1 ASecondary Current1A
Primary CurrentSelect code from ratio table
Dimensions
74.5
47
45
S1 S2
24
24
21.1
33.7
P2 P1
TRIAC
SC
M3 Screw M3 Screw
S2 S1
P2 P1
How to Order / Model Reference
eg - / J S 3 6 S 0 0 0 0 A
Model J S 3 6 S
1 ASecondary Current1A
Primary CurrentSelect code from ratio table
Dimensions
TRIAC
SC
M3 Screw M3 Screw
S2 S1
P2 P1
35.8
26.2
P2 P1
64.1
41.1
33.1
S1 S2
17
17
TRIAC
SC
M3 Screw M3 Screw
S2 S1
P2 P1
21.140.2
P2 P1
91.4
57
57.1
S1 S2
36
36
Current Transformer Ratios
cl. 0.5S cl. 1 cl. 3
cl. 0.6 cl. 1.2 cl. 2.4
Metering Burden(VA)PrimaryCurrent
(A)Code
1A Secondary
Current Transformer Ratios
cl. 0.5S cl. 1 cl. 3
cl. 0.6 cl. 1.2 cl. 2.4
Metering Burden(VA)PrimaryCurrent
(A)Code
1A Secondary
Current Transformer Ratios
cl. 0.5S cl. 1 cl. 3
cl. 0.6 cl. 1.2 cl. 2.4
Metering Burden(VA)PrimaryCurrent
(A)Code
1A Secondary
60 0.2 06075 0.5 075
100 0.5 100125 1.0 125150 1.0 150200 1.0 200
100 1.0 100125 1.0 125150 1.0 150200 0.5 200250 1.0 250300 1.5 300
300 1.5 300400 0.5 400500 0.5 500600 0.5 600
65 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
SPECIFICATION
Accuracy
Output Terminals
System Voltage
Overload withstand
Compliant with
Operating Temperature Range
Relative Humidity
Latch/Unlatch
Test Voltage
Frequency Range
Protection Level
Insulation Category
Class 1.0 / 3.0
2 X M3-Screw, with Terminals cover
720V(0.72kV)
1.2 times rated current continuously
IEC/EN61869-2 & IEC61010-1
-20˚C to 55˚C
0-85% non-condensing
about 100 times
3kV for 1minute
50/60Hz
Bipolar 6.5Vp
CATⅡ or CATⅢ 600VAC
• PC spring, output-terminal, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified
APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
HOW TO USE
SPLIT-CORE CURRENT TRANSFORMER
JS18S-XXX-1A series
• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts• Customizing output lead wire
JS series of split-core current transformer offers 1A at secondary from sensed primary current for metering application. It can be used for power meter, distribution system, control panels, switchgear and other equipment. It is designed to install to live power line without disconnection as split-core compact type. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.
2 3
4 5 6
1
P2 P1
METER
S1 S2 M3-Screwdriver
8mm
Terminalcover
CLOSE
Terminalcover
OPEN
CURRENT TRANSFORMER RATIOS / DIMENSIONS
66PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
Current Transformer Ratios
cl. 0.5S cl. 1 cl. 3
cl. 0.6 cl. 1.2 cl. 2.4
Metering Burden(VA)PrimaryCurrent
(A)Code
1A Secondary
How to Order / Model Reference
eg - / J S 1 8 S 0 0 0 0 A
Model J S 1 8 S
1 ASecondary Current
1A
Primary CurrentSelect code from ratio table
100 0.2 10075 0.2 07560 0.2 06050 0.2 050
125 0.2 125150 0.2 150200 0.2 200
Installation
The Sample of customized product
ㆍSplit-core CT must be handled with care. A damage caused from the careless handling will not be covered by warranty.
ㆍThe product is designed to meet operating environments dened by the industrial standard IP20.
ㆍBe careful to install the product with the correct polarity.
ㆍDo not install the product if an application exceed the specications of the product.
ㆍRecommended to use the terminals specied by J&D.
Precautions for the Warranty of QualityYEARS
5
W A R R A N T Y
ㆍProtection circuit built in inside of the product for user safety. An additional external protection circuit would be impacted on the feature.
ㆍThe product is designed for measuring sinusoidal 50/60Hz of primary current. Be aware that it is possible to occur the signicant error if it is used to measure non-sinusoidal.
ㆍUse Split-core CT with proper diameter to t the conductor, otherwise it may cause the ratio error and the phase shift.
ㆍBe careful to install Split-core CT without any pollutions on the core surfaces. The pollutions such as moisture, dust and rusty can be caused the error. After removing the pollutions, recommended to use WD-40 or CRC5-56 on the core surfaces.
ㆍCheck whether the secondary leads is connected correctly or not. If the connection is not correctly, the secondary output could be lower than the expected one.
Check Point for the Accurate MeasurementP R O P E R T I E S
ELECTRICAL
ㆍPlease provide the technical requirements for a technical evaluation.
ㆍThe color of housing is changeable upon the customer’s requirements.
ㆍThe leads can be mounted on the terminals by J&D.
ㆍA protective tailor-made housing is available.
Remarks for the Customized ProductsODM
ON RE Q UEST
TRIAC
SC
M3Screw
M3Screw
S2 S1
P2 P1
INTERNAL CIRCUITDRAWING
S1S2
METER
P2P1
METER
P2P1
35.8
26
P2 P1S1 S2
77.6
49.1
44.1
18
18
JS18S + Optional Leadwire
ㆍStandard length of lead wire is 2M, but the length may be altered according to the customer’s needs.
ㆍThe lead wire connections are protected by a terminal cover which is secured with a sticker label.
(unit : mm)
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In
67 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
• Steel spring plate, output-terminal, secure locking . hinge, one-touch structure easily to install to existing equipment such as a power distribution board• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified
APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
SPLIT-CORE CURRENT TRANSFORMER
JM21N-XXX-1A series
• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts• Customizing output lead wire
JM21N series of split-core current transformer offers 1A at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JM21N series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.
SPECIFICATION
Accuracy
Output Terminals
System Voltage
Overload withstand
Compliant with
Operating Temperature Range
Relative Humidity
Latch/Unlatch
Test Voltage
Frequency Range
Protection Level
Insulation Category
IEC Class 0.5S / ANSI Class 0.6
Terminal Block(2P) - PART NUMBER : LM5.08/02/90 SW(black)
720V(0.72kV)
1.2 times rated current continuously
IEC/EN61869-2, IEEE/ANSI C57.13 & IEC61010-1
-20˚C to 55˚C
0-85% non-condensing
about 100 times
3kV for 1minute
50/60Hz
Bipolar 6.5Vp
CATⅡ or CATⅢ 600VAC
HOW TO USE
2 3
4 5
14
CURRENT TRANSFORMER RATIOS / DIMENSIONS
68PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In
DIN RAIL MOUNTING Mount the bracket on the rail and install current transformer
PANEL MOUNTING Tighten screws on the hole to mount bracket and install current transformer
ㆍSplit-core CT must be handled with care. A damage caused from the careless handling will not be covered by warranty.
ㆍThe product is designed to meet operating environments dened by the industrial standard IP20.
ㆍBe careful to install the product with the correct polarity.
ㆍDo not install the product if an application exceed the specications of the product.
ㆍRecommended to use the terminals specied by J&D.
Precautions for the Warranty of QualityYEARS
5
W A R R A N T Y
ㆍProtection circuit built in inside of the product for user safety. An additional external protection circuit would be impacted on the feature.
ㆍThe product is designed for measuring sinusoidal 50/60Hz of primary current. Be aware that it is possible to occur the signicant error if it is used to measure non-sinusoidal.
ㆍUse Split-core CT with proper diameter to t the conductor, otherwise it may cause the ratio error and the phase shift.
ㆍBe careful to install Split-core CT without any pollutions on the core surfaces. The pollutions such as moisture, dust and rusty can be caused the error. After removing the pollutions, recommended to use WD-40 or CRC5-56 on the core surfaces.
ㆍCheck whether the secondary leads is connected correctly or not. If the connection is not correctly, the secondary output could be lower than the expected one.
Check Point for the Accurate MeasurementP R O P E R T I E S
ELECTRICAL
ㆍPlease provide the technical requirements for a technical evaluation.
ㆍThe color of housing is changeable upon the customer’s requirements.
ㆍThe leads can be mounted on the terminals by J&D.
ㆍA protective tailor-made housing is available.
Remarks for the Customized Products
ODMON RE Q U EST
INTERNAL CIRCUITDRAWING
28.4
9
95
80.5
4.7 7.2
19.7
2.5
• PANEL MOUNT
51.5
46
7035
35
24.27
• DIN RAIL MOUNT
S2S1
7060
64228
Optional lead wiresBlack & White orBrown & Yellow colors of UL1015#18
2840.3
23.8
14.5
2000 ± 50AWG
#18
8
Relay cable(common)(attached with CT)
Part-NO. : 56002(red)
TRIAC
SC
P2P1
S2S1
BLACKWIRE
WHITEWIRE
I
Current Transformer Ratios
cl. 0.5S cl. 1 cl. 3
cl. 0.6 cl. 1.2 cl. 2.4
Metering Burden(VA)PrimaryCurrent
(A)Code
1A Secondary
How to Order / Model Reference
eg - / J M 2 1 N 0 0 0 0 A
Model J M 2 1 N
1 ASecondary Current
1A
Primary CurrentSelect code from ratio table
100 0.2 100125 0.2 125150 0.2 150200 0.2 200250 0.2 250
69 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
• High quality comprehensive measurement• Available in a wide range of transformer ratings• Accuracy up to Class 0.5S
APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels
FEATURES
NOTICE
BENEFITS• Faster installation• Cost effective• Long product life
HOW TO USE
SPLIT-CORE CURRENT TRANSFORMER
JSC-XX-XXXX-1A series
• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts• Customizing output lead wire
JSC series of split-core current transformer offers 1A at secondary from sensed primary current for metering application. It can be used for power meter, distribution system, control panels, switchgear and other equipment. It is designed to install to live power line without disconnection as split-core compact type. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.
SPECIFICATION
Accuracy
Leads
System Voltage
Overload withstand
Compliant with
Operating Temperature Range
Relative Humidity
Test Voltage
Frequency Range
Protection Level
Insulation Category
Class 0.5S / 1.0 / 3.0
18AWG, 600VAC
720V(0.72kV)
1.2 times rated current continuously
IEC/EN61869-2 & IEC61010-1
-20˚C to 60˚C
0-90% non-condensing
3kV for 1minute
50/60Hz
Bipolar 6.5Vp
CATⅡ or CATⅢ 600VAC
2 3
4 5 6
1
JSC-01-300-1A300A : 1A Lot no : 120601IEC60044-1 class 1.0, 0.5VA F=50/60Hz Umax=720V Ui=3kV
Source Side S1 : White S2 : Black
JSC-02-800-1A800A : 1A Lot no : 120601IEC60044-1 class 0.5, 1.0VA F=50/60Hz Umax=720V Ui=3kV
Source Side S1 : White S2 : Black
JSC-03-1600-1A1600A : 1A Lot no : 120601IEC60044-1 class 0.5, 10VA F=50/60Hz Umax=720V Ui=3kV
Source Side S1 : White S2 : Black
CURRENT TRANSFORMER RATIOS / DIMENSIONS
70PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Dimensions
3929
94
Dimensions Dimensions
TRIACSC
Black wire
(S2)White wire
(S1)
P2
P1
How to Order / Model Reference
eg - - / J S C 0 1 0 0 0 10 A
Model J S C - 0 1
1 ASecondary Current
1A
Primary CurrentSelect code from ratio table
933822
32
92
P1
P2
TRIACSC
Black wire
(S2)White wire
(S1)
P2
P1
3929
124
196
141
22
62
124
P1
P2
TRIACSC
Black wire
(S2)White wire
(S1)
P2
P1
3929
124
128
124
62
P1
P2
7322
How to Order / Model Reference
eg - - / J S C 0 2 0 0 0 10 A
Model J S C - 0 2
1 ASecondary Current
1A
Primary CurrentSelect code from ratio table
How to Order / Model Reference
eg - - / J S C 0 3 0 0 0 10 A
Model J S C - 0 3
1 ASecondary Current
1A
Primary CurrentSelect code from ratio table
Current Transformer Ratios
cl. 0.5S cl. 1 cl. 3
cl. 0.6 cl. 1.2 cl. 2.4
Metering Burden(VA)PrimaryCurrent
(A)Code
1A Secondary
Current Transformer Ratios
cl. 0.5S cl. 1 cl. 3
cl. 0.6 cl. 1.2 cl. 2.4
Metering Burden(VA)PrimaryCurrent
(A)Code
1A Secondary
Current Transformer Ratios
cl. 0.5S cl. 1 cl. 3
cl. 0.6 cl. 1.2 cl. 2.4
Metering Burden(VA)PrimaryCurrent
(A)Code
1A Secondary
100 0.5 0100150 1.5 0150200 0.5 0200250 0.5 0250300 0.5 0300400 0.5 0400
400 1.0 0400500 2.5 0500600 1.0 5.0 0600750 1.0 5.0 0750800 1.0 5.0 0800
1000 2.5 10.0 1000
800 1.0 5.0 08001000 1.0 5.0 10001200 5.0 10.0 12001250 5.0 10.0 12501500 10.0 20.0 15001600 10.0 20.0 16002000 10.0 20.0 20002400 10.0 20.0 2400
71 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
SPECIFICATION
Accuracy
Output Terminals
System Voltage
Overload withstand
Compliant with
Operating Temperature Range
Relative Humidity
Test Voltage
Frequency Range
Protection Level
Insulation Category
Class 0.5S / 1.0 / 3.0
2 X M3-Screw, with Terminals cover
720V(0.72kV)
1.2 times rated current continuously
IEC/EN61869-2 & IEC61010-1
-20˚C to 55˚C
0-85% non-condensing
3kV for 1minute
50/60Hz
Bipolar 6.5Vp
CATⅡ or CATⅢ 600VAC
• PC spring, output-terminal, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified
APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
HOW TO USE
SPLIT-CORE CURRENT TRANSFORMER
JSXXS-XXX-5A series
• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts• Customizing output lead wire
JS series of split-core current transformer offers 5A at secondary from sensed primary current for metering application. It can be used for power meter, distribution system, control panels, switchgear and other equipment. It is designed to install to live power line without disconnection as split-core compact type. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.
2 3
4 5 6
1
P2 P1
METER
S1 S2 M3-Screwdriver
8mm
Terminalcover
CLOSE
Terminalcover
OPEN
150A : 5A Lot no:120601IEC60044-1 class3.0, 1.5VA
F=50/60Hz Umax=720V Ui=3kV
JS17S-150/5A
S1 S2
JS24S-400/5A
S1 S2
400A : 5A Lot no:120601IEC60044-1 class 1.0, 0.5VA F=50/60Hz Umax=720V Ui=3kV
JS36S-500/5A
S1 S2
500A : 5A Lot no:120601IEC60044-1 class 0.5, 0.5VA F=50/60Hz Umax=720V Ui=3kV
CURRENT TRANSFORMER RATIOS
72PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
TRIAC
SC
M3 Screw M3 Screw
S2 S1
P2 P1
TRIAC
SC
M3 Screw M3 Screw
S2 S1
P2 P1
TRIAC
SC
M3 Screw M3 Screw
S2 S1
P2 P1
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
How to Order / Model Reference
eg - / J S 1 7 S 0 0 0 0 A
Model J S 1 7 S
5 ASecondary Current
5A
Primary CurrentSelect code from ratio table
Dimensions
How to Order / Model Reference
eg - / J S 2 4 S 0 0 0 0 A
Model J S 2 4 S
5 ASecondary Current
5A
Primary CurrentSelect code from ratio table
Dimensions
74.5
47
45
S1 S2
24
24
21.1
33.7
P2 P1
How to Order / Model Reference
eg - / J S 3 6 S 0 0 0 0 A
Model J S 3 6 S
5 ASecondary Current
5A
Primary CurrentSelect code from ratio table
Dimensions
35.8
26.2
P2 P1
64.1
41.1
33.1
S1 S2
17
17
21.140.2
P2 P1
91.4
57
57.1
S1 S2
36
36
Current Transformer Ratios
cl. 0.5S cl. 1 cl. 3
cl. 0.6 cl. 1.2 cl. 2.4
Metering Burden(VA)PrimaryCurrent
(A)Code
5A Secondary
Current Transformer Ratios
cl. 0.5S cl. 1 cl. 3
cl. 0.6 cl. 1.2 cl. 2.4
Metering Burden(VA)PrimaryCurrent
(A)Code
5A Secondary
Current Transformer Ratios
cl. 0.5S cl. 1 cl. 3
cl. 0.6 cl. 1.2 cl. 2.4
Metering Burden(VA)PrimaryCurrent
(A)Code
5A Secondary
150 0.2 150 100 1.5 100150 1.5 150200 0.5 200250 0.5 250300 0.5 300400 0.5 400
300 0.5 300400 0.5 400
200 2.5 200250 0.5 250
500 0.5 500600 0.5
2.52.55.0 600
73 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
SPECIFICATION
Accuracy
Output Terminals
System Voltage
Overload withstand
Compliant with
Operating Temperature Range
Relative Humidity
Latch/Unlatch
Test Voltage
Frequency Range
Protection Level
Insulation Category
Class 1.0 / 3.0
2 X M3-Screw, with Terminals cover
720V(0.72kV)
1.2 times rated current continuously
IEC/EN61869-2 & IEC61010-1
-20˚C to 55˚C
0-85% non-condensing
about 100 times
3kV for 1minute
50/60Hz
Bipolar 6.5Vp
CATⅡ or CATⅢ 600VAC
• PC spring, output-terminal, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified
APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
HOW TO USE
SPLIT-CORE CURRENT TRANSFORMER
JSXXS-XXX-5A series
• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts• Customizing output lead wire
JS series of split-core current transformer offers 5A at secondary from sensed primary current for metering application. It can be used for power meter, distribution system, control panels, switchgear and other equipment. It is designed to install to live power line without disconnection as split-core compact type. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.
2 3
4 5 6
1
P2 P1
METER
S1 S2 M3-Screwdriver
8mm
Terminalcover
CLOSE
Terminalcover
OPEN
CURRENT TRANSFORMER RATIOS
74PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In
Current Transformer Ratios
cl. 0.5S cl. 1 cl. 3
cl. 0.6 cl. 1.2 cl. 2.4
Metering Burden(VA)PrimaryCurrent
(A)Code
5A Secondary
How to Order / Model Reference
eg - / J S 1 8 S 0 0 0 0 A
Model J S 1 8 S
5 ASecondary Current
5A
Primary CurrentSelect code from ratio table
100 1.0 10075 1.0 7550 1.0 50
150 1.0 125200 1.0 150250 1.0 200
Installation
The Sample of customized product
ㆍSplit-core CT must be handled with care. A damage caused from the careless handling will not be covered by warranty.
ㆍThe product is designed to meet operating environments dened by the industrial standard IP20.
ㆍBe careful to install the product with the correct polarity.
ㆍDo not install the product if an application exceed the specications of the product.
ㆍRecommended to use the terminals specied by J&D.
Precautions for the Warranty of QualityYEARS
5
W A R R A N T Y
ㆍProtection circuit built in inside of the product for user safety. An additional external protection circuit would be impacted on the feature.
ㆍThe product is designed for measuring sinusoidal 50/60Hz of primary current. Be aware that it is possible to occur the signicant error if it is used to measure non-sinusoidal.
ㆍUse Split-core CT with proper diameter to t the conductor, otherwise it may cause the ratio error and the phase shift.
ㆍBe careful to install Split-core CT without any pollutions on the core surfaces. The pollutions such as moisture, dust and rusty can be caused the error. After removing the pollutions, recommended to use WD-40 or CRC5-56 on the core surfaces.
ㆍCheck whether the secondary leads is connected correctly or not. If the connection is not correctly, the secondary output could be lower than the expected one.
Check Point for the Accurate MeasurementP R O P E R T I E
S
ELECTRICAL
ㆍPlease provide the technical requirements for a technical evaluation.
ㆍThe color of housing is changeable upon the customer’s requirements.
ㆍThe leads can be mounted on the terminals by J&D.
ㆍA protective tailor-made housing is available.
Remarks for the Customized ProductsODM
ON RE Q U EST
TRIAC
SC
M3Screw
M3Screw
S2 S1
P2 P1
INTERNAL CIRCUITDRAWING
S1S2
METER
P2P1
METER
P2P1
35.8
26
P2 P1S1 S2
77.6
49.1
44.1
18
18
JS18S + Optional Leadwire
ㆍStandard length of lead wire is 2M, but the length may be altered according to the customer’s needs.ㆍThe lead wire connections are protected by
a terminal cover which is secured with a sticker label.
(unit : mm)
75 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
• High quality comprehensive measurement• Available in a wide range of transformer ratings• Accuracy up to Class 0.5S
APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels
FEATURES
NOTICE
BENEFITS• Faster installation• Cost effective• Long product life
HOW TO USE
SPLIT-CORE CURRENT TRANSFORMER
JSC-XX-XXXX-5A series
• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts• Customizing output lead wire
JSC series of split-core current transformer offers 5A at secondary from sensed primary current for metering application. It can be used for power meter, distribution system, control panels, switchgear and other equipment. It is designed to install to live power line without disconnection as split-core compact type. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.
SPECIFICATION
Accuracy
Leads
System Voltage
Overload withstand
Compliant with
Operating Temperature Range
Relative Humidity
Test Voltage
Frequency Range
Protection Level
Insulation Category
Class 0.5S / 1.0 / 3.0
18AWG,600VAC
720V(0.72kV)
1.2 times rated current continuously
IEC/EN61869-2 & IEC61010-1
-20˚C to 60˚C
0-90% non-condensing
3kV for 1minute
50/60Hz
Bipolar 6.5Vp
CATⅡ or CATⅢ 600VAC
2 3
4 5 6
1
JSC-01-300-5A300A : 5A Lot no : 120601IEC60044-1 class 1.0, 0.5VA F=50/60Hz Umax=720V Ui=3kV
Source Side S1 : White S2 : Black
JSC-02-800-5A800A : 5A Lot no : 120601IEC60044-1 class 0.5, 1.0VA F=50/60Hz Umax=720V Ui=3kV
Source Side S1 : White S2 : Black
JSC-03-1600-5A1600A : 5A Lot no : 120601IEC60044-1 class 0.5, 10VA F=50/60Hz Umax=720V Ui=3kV
Source Side S1 : White S2 : Black
CURRENT TRANSFORMER RATIOS / DIMENSIONS
76PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In
Dimensions
3929
94
Dimensions Dimensions
TRIACSC
Black wire
(S2)White wire
(S1)
P2
P1
How to Order / Model Reference
eg - - / J S C 0 1 0 0 0 50 A
Model J S C - 0 1
5 ASecondary Current
5A
Primary CurrentSelect code from ratio table
933822
32
92
P1
P2
TRIACSC
Black wire
(S2)White wire
(S1)
P2
P1
3929
124
196
141
22
62
124
P1
P2
TRIACSC
Black wire
(S2)White wire
(S1)
P2
P1
3929
124
128
124
62
P1
P2
7322
How to Order / Model Reference
eg - - / J S C 0 2 0 0 0 50 A
Model J S C - 0 2
5 ASecondary Current
5A
Primary CurrentSelect code from ratio table
How to Order / Model Reference
eg - - / J S C 0 3 0 0 0 50 A
Model J S C - 0 3
5 ASecondary Current
5A
Primary CurrentSelect code from ratio table
Current Transformer Ratios
cl. 0.5S cl. 1 cl. 3
cl. 0.6 cl. 1.2 cl. 2.4
Metering Burden(VA)PrimaryCurrent
(A)Code
5A Secondary
Current Transformer Ratios
cl. 0.5S cl. 1 cl. 3
cl. 0.6 cl. 1.2 cl. 2.4
Metering Burden(VA)PrimaryCurrent
(A)Code
5A Secondary
Current Transformer Ratios
cl. 0.5S cl. 1 cl. 3
cl. 0.6 cl. 1.2 cl. 2.4
Metering Burden(VA)PrimaryCurrent
(A)Code
5A Secondary
100 0.5 0100150 1.5 0150200 1.5 0200250 0.5 0250300 0.5 0300400 0400
400 1.0 0400500 2.5 0500600 1.0 5.0 0600750 1.0 5.0 0750800 1.0 5.0 0800
1000 2.5 10.0 1000
800 1.0 5.0 08001000 1.0 5.0 10001200 5.0 10.0 12001250 5.0 10.0 12501500 10.0 20.0 15001600 10.0 20.0 16002000 10.0 20.0 20002400 10.0 20.0 2400
• The mating surfaces of the transformer cores are protected by a rubber gasket.• The transformer cases are UV stabilized thermoplastic.• Water proof (IP67 or IP65 Option)
APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
HOW TO USE
PRECISION OUTDOOR USESPLIT-CORE CURRENT TRANSFORMER
JSXXL-XXX-100mA series
• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts• Customizing output lead wire
The JSXXL series Water proof Split Core Current Transformers are designed for assembly to an existing electrical installation without the need for dismantling the primary bus or cables.These current transformers are a water proof design suitable for use outdoor or in direct burial applications.
77 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
SPECIFICATION
Accuracy
Output Terminals
System Voltage
Overload withstand
Compliant with
Operating Temperature Range
Relative Humidity
Test Voltage
Frequency Range
Protection Level
Insulation Category
Class 1.0
Twisted pair, 18AWG cable
720V(0.72kV)
1.2 times rated current continuously
IEC/EN61869-2 & IEC61010-1
-20˚C to 55˚C
0-85% non-condensing
3kV for 1minute
50/60Hz
Bipolar 6.5Vp
CATⅣ 300VAC
Adding perfect Gasket forpreventing core erosion
200A : 100mA Lot no:120601IEC60044-1 class 1.0S, 0.05VAF=50/60Hz Umax=720V Ui=3kV
JS21L-200/100mA
S1 S2
CURRENT TRANSFORMER RATIOS / DIMENSIONS
78PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
How to Order / Model Reference
eg - / J S 2 1 L 00 0 001 mA
Model J S 2 1 L
1 0 0 mASecondary Current100mA
Primary CurrentSelect code from ratio table
How to Order / Model Reference
eg - / J S 3 2 L 00 0 001 mA
Model J S 3 2 L
1 0 0 mASecondary Current100mA
Primary CurrentSelect code from ratio table
Current Transformer Ratios
100 0.05 100125 0.05 125150 0.05 150200 0.05 200250 0.05 250300 0.05 300
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
100mA Secondary
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In
Dimensions Dimensions
Bipo
lar
Dire
ctio
nal
Zeno
r Dio
de
S2S1
P2P1
Yellow wire
(S1)
Brown wire
(S2) Bipo
lar
Dire
ctio
nal
Zeno
r Dio
de
S2S1
P2P1
Yellow wire
(S1)
Brown wire
(S2)
Current Transformer Ratios
cl. 0.2S cl. 0.5S cl. 1
cl. 0.3 cl. 0.6 cl. 1.2
Metering Burden(VA)PrimaryCurrent
(A)Code
100mA Secondary
300 0.05 300400 0.05 400500 0.05 500600 0.05 600
98
932
32
62
1.5
36.5
40.4 5.2
54.4
21
21
78.5
4929
.5
1.6 8
1.5
2933
5.2
47
50
79 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
• The mating surfaces of the transformer cores are protected by a rubber gasket.• The transformer cases are UV stabilized thermoplastic.• Water proof (IP67 or IP65 Option)
APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
HOW TO USE
PRECISION OUTDOOR USESPLIT-CORE CURRENT TRANSFORMER
JSXXL-XXX-1A series
• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts• Customizing output lead wire
The JSXXL series Water proof Split Core Current Transformers are designed for assembly to an existing electrical installation without the need for dismantling the primary bus or cables.These current transformers are a water proof design suitable for use outdoor or in direct burial applications.
SPECIFICATION
Accuracy
Output Terminals
System Voltage
Overload withstand
Compliant with
Operating Temperature Range
Relative Humidity
Test Voltage
Frequency Range
Protection Level
Insulation Category
Class 0.5S / 1.0 / 3.0
Twisted pair, 18AWG cable
720V(0.72kV)
1.2 times rated current continuously
IEC/EN61869-2 & IEC61010-1
-20˚C to 55˚C
0-85% non-condensing
3kV for 1minute
50/60Hz
Bipolar 6.5Vp
CATⅣ 300VAC
Adding perfect Gasket forpreventing core erosion
250A : 1A Lot no:120601IEC60044-1 class 1.0S, 1.0VAF=50/60Hz Umax=720V Ui=3kV
JS21L-250/1A
S1 S2
80PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
CURRENT TRANSFORMER RATIOS / DIMENSIONS
How to Order / Model Reference
eg - / J S 2 1 L 0 0 0 0 A
Model J S 2 1 L
1 ASecondary Current
1A
Primary CurrentSelect code from ratio table
How to Order / Model Reference
eg - / J S 3 2 L 0 0 0 0 A
Model J S 3 2 L
1 ASecondary Current
1A
Primary CurrentSelect code from ratio table
Current Transformer Ratios
cl. 0.5S cl. 1 cl. 3
cl. 0.6 cl. 1.2 cl. 2.4
Metering Burden(VA)PrimaryCurrent
(A)Code
1A Secondary
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In
Dimensions Dimensions98
932
32
62
1.5
36.5
40.4 5.2
54.4
21
21
78.5
4929
.5
1.6 8
1.5
2933
5.2
47
50
100 1.0 100125 1.0 125150 1.0
1.0150
200 200250 1.0 250300 1.5 300
Current Transformer Ratios
cl. 0.5S cl. 1 cl. 3
cl. 0.6 cl. 1.2 cl. 2.4
Metering Burden(VA)PrimaryCurrent
(A)Code
1A Secondary
300 1.5 300400 0.5 400500 0.5 500600 0.5 600
TRIA
C SC
S2S1
P2P1
Yellow wire
(S1)
Brown wire
(S2)
TRIA
C SC
S2S1
P2P1
Yellow wire
(S1)
Brown wire
(S2)
• The mating surfaces of the transformer cores are protected by a rubber gasket.• The transformer cases are UV stabilized thermoplastic.• Water proof (IP67 or IP65 Option)
APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system
FEATURES
NOTICE
BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
HOW TO USE
PRECISION OUTDOOR USESPLIT-CORE CURRENT TRANSFORMER
JSXXL-XXX-5A series
• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts• Customizing output lead wire
The JSXXL series Water proof Split Core Current Transformers are designed for assembly to an existing electrical installation without the need for dismantling the primary bus or cables.These current transformers are a water proof design suitable for use outdoor or in direct burial applications.
81 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
SPECIFICATION
Accuracy
Output Terminals
System Voltage
Overload withstand
Compliant with
Operating Temperature Range
Relative Humidity
Test Voltage
Frequency Range
Protection Level
Insulation Category
Class 0.5S / 1.0 / 3.0
Twisted pair, 18AWG cable
720V(0.72kV)
1.2 times rated current continuously
IEC/EN61869-2 & IEC61010-1
-20˚C to 55˚C
0-85% non-condensing
3kV for 1minute
50/60Hz
Bipolar 6.5Vp
CATⅣ 300VAC
Adding perfect Gasket forpreventing core erosion
250A : 5A Lot no:120601IEC60044-1 class 1.0S, 0.5VAF=50/60Hz Umax=720V Ui=3kV
JS21L-250/5A
S1 S2
TRIA
C SC
S2S1
P2P1
Yellow wire
(S1)
Brown wire
(S2)
TRIA
C SC
S2S1
P2P1
Yellow wire
(S1)
Brown wire
(S2)
CURRENT TRANSFORMER RATIOS / DIMENSIONS
82PRECISE SPLIT-CORE AC CURRENT TRANSFORMER
How to Order / Model Reference
eg - / J S 2 1 L 0 0 0 0 A
Model J S 2 1 L
5 ASecondary Current
5A
Primary CurrentSelect code from ratio table
How to Order / Model Reference
eg - / J S 3 2 L 0 0 0 0 A
Model J S 3 2 L
5 ASecondary Current
5A
Primary CurrentSelect code from ratio table
Current Transformer Ratios
cl. 0.5S cl. 1 cl. 3
cl. 0.6 cl. 1.2 cl. 2.4
Metering Burden(VA)PrimaryCurrent
(A)Code
5A Secondary
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In
Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In
Dimensions Dimensions
98
932
32
62
1.5
36.5
40.4 5.2
54.4
21
21
78.5
4929
.5
1.6 8
1.5
2933
5.2
47
50
Current Transformer Ratios
cl. 0.5S cl. 1 cl. 3
cl. 0.6 cl. 1.2 cl. 2.4
Metering Burden(VA)PrimaryCurrent
(A)Code
5A Secondary
100 1.5 100150 1.5
1.5150
200 200250 0.5 250300 0.5 300400 0.5 400
200 2.5 200250 0.5 250300 0.5 300400 0.5 2.5 400500 0.5 2.5 500600 0.5 5.0 600