4
INVALCO’s Multipulse PD flowmeters utilize the oscillating piston design principle. Performance is enhanced by the use of modern engineering materials to provide a cost effective and reliable solution for a wide range of industrial flow measure- ment applications. Features IP67 (NEMA 4X) 316L stainless steel or aluminum construction. Nominal flow range 0.5 to 13.2 gpm (2 to 50 lpm) Performance independent of flow profile or mounting orientation. Single moving part. Pressure to 5,150 psi (350 bar). Temperature to 300°F (150°C) Both open collector and reed switch output as standard. Measures low and high viscosity liquids up to 1,000,000 centipoise. Adaptable to hygienic applications. Specifications Options Threaded, flanged or hygienic process connections. Explosionproof or intrinsically safe operation. Integral self powered flow rate-totalizer with scaled pulse, analog and flow alarm outputs. Model Prefix MP025S MP025A MP025H Body Material 316L stainless steel Aluminum 316L stainless steel Nominal Flow Spans* Accuracy Repeatability Maximum Pressure 1500 psi (100 bar) 1200 psi (80 Bar) 5150 psi (350 bar) Temperature Range Piston Material O-Ring Material Reed Switch Output Open Collector Output Electrical Connection Process Connections 1" BSPP or NPT 1" ANSI 150/300RF Flanges 1" BSPP or NPT 1" BSPP or NPT DN25 PN16/40 flanges Lap Joint Flanges on Request (others on request) 40mm triclamp hygienic (others on request) Environmental Protection Recommended Filtering 0.5 to 13.2 gpm (2 to 50 lpm) *Turndow n (flow range) varies in accordance w ith effective viscosity of metered liquid +/-0.5% of rate Accuracy and turndow n can be improved w hen utilizing the linearization feature of the optional rate totalizer. Typically +/-0.03% under steady flow conditions Three ranges covering operation from - 40°F to 300°F (-40°C to 150°C) limited to 176°F (80°C) w ith integral electronic register PEEK (polyetheretherketone), optional carbon filled teflon viton, EPR (EPDM), teflon encapsulated viton or nitrile (Buna-N) 30 vdc maximum voltage, 20mA maximum current Pulse resolution: 76 pulses / gallon (nominally 20 pulses / liter) 5 to 24vdc (25vdc maximum) 3 w ire NPN (sinking current) 250 microns (50 mesh) 20mA maximum current - 3300 ft (1000 meters) maximum transmission Pulse resolution: nominally 380 pulses / gallon (100 pulses / liter) M20 x 1.5 or 1/2" NPT female entry IP67 (Nema 4X), optionally flameproof to Exd IIB T4 (Class 1, Groups C & D) Bulletin SSIT021 Positive Displacement Meters 1” (25mm) Positive Displacement Flowmeter FMC Energy Systems ! Fluid Control ! Stephenville, Texas 76401 ! Telephone: 254/968-2181 ! FAX 254/968-5709 ! Toll Free: 800/468-2526

Positive Displacement Meters 1” (25mm) Positive ...superiorpumpsupplies.com.au/spt/sites/default/files...Positive Displacement Meters 1” (25mm) Positive Displacement Flowmeter

  • Upload
    others

  • View
    12

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Positive Displacement Meters 1” (25mm) Positive ...superiorpumpsupplies.com.au/spt/sites/default/files...Positive Displacement Meters 1” (25mm) Positive Displacement Flowmeter

INVALCO’s Multipulse PD flowmeters utilize the oscillatingpiston design principle. Performance is enhanced by the useof modern engineering materials to provide a cost effective andreliable solution for a wide range of industrial flow measure-ment applications.

Features

IP67 (NEMA 4X) 316L stainless steel or aluminumconstruction.Nominal flow range 0.5 to 13.2 gpm (2 to 50 lpm)Performance independent of flow profile or mountingorientation.Single moving part.Pressure to 5,150 psi (350 bar).Temperature to 300°F (150°C)Both open collector and reed switch output as standard.Measures low and high viscosity liquids up to 1,000,000centipoise.Adaptable to hygienic applications.

Specifications

Options

Threaded, flanged or hygienic process connections.Explosionproof or intrinsically safe operation.Integral self powered flow rate-totalizer with scaledpulse, analog and flow alarm outputs.

Model Prefix MP025S MP025A MP025HBody Material 316L stainless steel Aluminum 316L stainless steelNominal Flow Spans*

Accuracy

Repeatability Maximum Pressure 1500 psi (100 bar) 1200 psi (80 Bar) 5150 psi (350 bar)Temperature Range

Piston MaterialO-Ring MaterialReed Switch Output

Open Collector Output

Electrical ConnectionProcess Connections 1" BSPP or NPT

1" ANSI 150/300RFFlanges 1" BSPP or NPT 1" BSPP or NPT

DN25 PN16/40 f langes Lap Joint Flanges on Request (others on request)40mm triclamp hygienic

(others on request)Environmental ProtectionRecommended Filtering

0.5 to 13.2 gpm (2 to 50 lpm)

*Turndow n (f low range) varies in accordance w itheffective viscosity of metered liquid

+/-0.5% of rateAccuracy and turndow n can be improved

w hen utilizing the linearization feature of the optional rate totalizer.Typically +/-0.03% under steady f low conditions

Three ranges covering operation from - 40°F to 300°F (-40°C to 150°C)limited to 176°F (80°C) w ith integral electronic register

PEEK (polyetheretherketone), optional carbon f illed teflonviton, EPR (EPDM), teflon encapsulated viton or nitrile (Buna-N)

30 vdc maximum voltage, 20mA maximum currentPulse resolution: 76 pulses / gallon (nominally 20 pulses / liter)

5 to 24vdc (25vdc maximum) 3 w ire NPN (sinking current)

250 microns (50 mesh)

20mA maximum current - 3300 ft (1000 meters) maximum transmissionPulse resolution: nominally 380 pulses / gallon (100 pulses / liter)

M20 x 1.5 or 1/2" NPT female entry

IP67 (Nema 4X), optionally f lameproof to Exd IIB T4 (Class 1, Groups C & D)

Bulletin SSIT021

Positive Displacement Meters1” (25mm) Positive

Displacement Flowmeter

FMC Energy Systems ! Fluid Control ! Stephenville, Texas 76401 ! Telephone: 254/968-2181 ! FAX 254/968-5709 ! Toll Free: 800/468-2526

Page 2: Positive Displacement Meters 1” (25mm) Positive ...superiorpumpsupplies.com.au/spt/sites/default/files...Positive Displacement Meters 1” (25mm) Positive Displacement Flowmeter

Application Flexibility

Commonly metered liquids range from non-conductivelow viscosity solvents to extremely viscous lubricants,chemicals and food bases.Application flexibility is further enhanced as meter per-formance is independent of flow profile eliminating theneed for straight pipe runs required with most othermetering technologies.Multipulse has no stagnate chambers to harbor contami-nants. There are no restrictions on mounting orientationand the flowmeter may be operated under vacuum flow,pumped flow or gravity flow conditions.

Design Simplicity

The simple and robust design of the INVALCO PD Flow-meter offers the advantage of only one moving part withboth high resolution open collector and reed switch out-put as standard.As each piston rotation passes a known liquid volume,the inherent repeatability of the multipulse positive dis-placement flowmeter makes it particularly suited tobatching and dispensing duties.

Ordering Information

Issue/Rev. 0.2 (6/04)2 • SSIT021

MP025 Body material

S 316L Stainless Steel

A Aluminium H High Pressure 316L Stainless Steel

Piston and Bearing material2 PEEK ( Polyetheretherkeytone ) (Standard)3 CFT ( carbon f illed teflon ) 9 Special

Partition material1 Ceramic ( for non lubricating liquids)2 316L Stainless Steel (Standard)

O-ring material1 Viton ( standard )2 EPDM3 Teflon encapsulated viton4 Nitrile (Buna-N)

Temperature ranges- 1 - 40~140°F ( - 40~60°C ) - 2 50~250°F ( 10~120°C ) *see Note 1- 3 140~300°F (60~150°C) *see Notes 1 & 2

Process connections 1 1" (25mm) BSPP female 2 1" (25mm) NPT female3 1-1/2" (51mm OD) Tri-clamp ferrules 4 1" ANSI-150 RF flanges 5 1" ANSI-300 RF flanges 6 DN25-PN16 flanges 7 DN25-PN40 flanges9 Customer nominated special

Conduit Entry1 M20 x 1.5mm female2 1/2" NPT female

Options (Integrally Mounted)00 NoneEX Flameproof (Exd)R1 RT11 rate / totalizer (scaleable pulse output & NLC*) R2 RT12 rate / totalizer (RT11+4-20mA output & alarms)

Note 1: Optional electronic register must be remotely mounted if the operating temperature exceeds 176°F (80°C).Note 2: PEEK piston & open collector output only.Note 3: NLC: MULTIPOINT NON LINEARITY CORRECTION

Page 3: Positive Displacement Meters 1” (25mm) Positive ...superiorpumpsupplies.com.au/spt/sites/default/files...Positive Displacement Meters 1” (25mm) Positive Displacement Flowmeter

Dimensions

Issue/Rev. 0.2 (6/04) SSIT021 • 3

Flange size and type Dim "A"1" ANSI 150 RF 6" (152mm)1" ANSI 300 RF 6.7" (170mm)DN25PN16 6.5" (165mm)DN25 PN40 6.8" (173mm)

Page 4: Positive Displacement Meters 1” (25mm) Positive ...superiorpumpsupplies.com.au/spt/sites/default/files...Positive Displacement Meters 1” (25mm) Positive Displacement Flowmeter

www.fmcinvalco.com

The specifications contained herein are subject to change without notice and any user of said specifications should verify from the manufacturer that the specificationsare currently in effect. Otherwise, the manufacturer assumes no responsibility for the use of specifications which may have been changed and are no longer in effect.

FMC Energy Systems Fluid Control Stephenville, TX 76401, Phone: 254/968-2181, FAX: 254/968-5709, Toll Free: 800/468-2526