Phu Kien Tram BTS Draka NK Cable

  • View
    95

  • Download
    11

Embed Size (px)

Text of Phu Kien Tram BTS Draka NK Cable

Antenna Line Products

version 3Your partner in quality cable solutions Draka NK Cables Ltd. P.O.Box 419, FIN-00101 Helsinki, FINLAND Tel. +358 10 5661, Fax +358 9 529 841 www.drakankc.fi6/2004

www.drakacomteq.com

Draka NK CablesJumper cable

Feeder cable + connector

The roots of the company date back to 1912 when a cord factory was established in Helsinki. After those times both the name and the owners have changed, but the manufacturing of high quality cables continues. We have built on our strengths from the early days, and in course of the time developed into a strong international company. Since 1999 we are part of the Draka Group. Our parent company, Draka Holding based in Amsterdam, is one of Europes leading cable companies in communication and installation cables.NK CABLES branded radio frequency

activities by complying with the principles of sustainable development. We are a proven antenna line supplier with network provider and operator experience on all continents. Our production facilities are located in Finland, China and Brazil, focusing their products in the respective home and neighbouring markets. An extensive sales network serves our customers worldwide.

cables have been designed to meet the highest quality and environmental standards. We take the environment into consideration in all our

Cable clamp

ContentsGeneral Information on 50 Ohm Radio Frequency CablesNK CABLES 50 Ohm Radio Frequency Cables

4 5 6-19 20-31 32-33 34-35 36-37 38-39 40-43

Feeder CablesGrounding kit

Superflexible Cables Jumpers Accessories Drums Environment and Quality Codes

EMP Protector

All information in this catalog is subject to change without prior notice.

2

3

CablesAll our cables are halogen free, non corrosive and can be manufactured with fire retardant and low smoke emission jacket in black (BHF) or grey (GHF). In addition to the products presented in this catalog, we supply coaxial antennas for tunnels and indoor solutions.

General Information on 50 Ohm Radio Frequency CablesFeeder cables are typically used for mobile telecommunication applications, such as GSM, WCDMA (UMTS), TDMA, D-AMPS, PCN, CDMA and TETRA. The function of the feeder cable is to transmit signal power between the transmission equipment and the antenna in all environmental conditions. The superflexible RFF cables are typically used as jumpers to connect the feeder cable to the transmission equipment or to the antenna in mobile telecommunication applications. The extraflexible RFE cables can be used for indoor and rooftop applications due to their excellent bending performance. In some cases RFE cables can eliminate the use of jumpers. Low attenuation at high frequencies, uniform impedance and low return loss are the most important qualities of NK CABLES branded radio frequency cables. In addition, our BHF jacketed RF cables pass the UL 1666 Flame test and can be supplied with a UL Rating of CATVR.

NK CABLES 50 Ohm Radio Frequency CablesFEEDER CABLES Type Product code Inner conductor diam. (mm) 3.1 4.8 7.0 9.0 13.0 17.5 21.2 Outer conductor diam. (mm) 9.5 13.9 19.7 24.9 35.8 46.5 55.9 Jacket diam. (mm) Standard length (m) Standard Drum type P6D P11D P14G P14G P21G P21G P21Q

RF 3/8"-50 RF 1/2"-50 RF 5/8"-50 RF 7/8"-50 RF 1 1/4"-50 RF 1 5/8"-50 RF 2 1/4"-50

NKRF03800 NKRF01200 NKRF05800 NKRF07800 NKRF11400 NKRF15800 NKRF21400

11.2 16.0 21.9 27.5 39.0 50.0 60.0

250 500 500 500 600 400 300

SUPERFLEXIBLE CABLES Type Product code Inner conductor diam. (mm) 1.9 2.6 3.55 9.4 13.6 17.5 Outer conductor diam. (mm) 6.4 9.0 11.9 24.9 35.8 46.5 Jacket diam. (mm) Standard length (m) Standard Drum type 5C 5C P11D P14G P21G P21G

RFF 1/4"-50 RFF 3/8"-50 RFF 1/2"-50 RFE 7/8"-50 RFE 1 1/4"-50 RFE 1 5/8"-50

NKRFF01400 NKRFF03800 NKRFF01200 NKRFE07800 NKRFE11400 NKRFE15800

7.4 10.1 13.5 27.5 39.0 50.0

250 250 500 500 600 400

4

5

RF 3/8 -5 0

Feeder cable

RF 3/8-50SpecificationsCONSTRUCTION Inner conductor Dielectric Outer conductor Jacketing Marking Copper-clad aluminium wire Cellular polyethylene Corrugated copper tube See table below NK Cables, cable type, manufacture week, year, batch number and meter mark 3.1 mm 8.0 mm 9.5 mm 11.2 mm ATTENUATIONPower rating kW

MECHANICAL CHARACTERISTICS Weight Maximum pulling force Minimum bending radius Single bending Repeated bending Operating temperature range Crush resistance Bending moment Recommended clamp distance 126 kg/km 1650 N 50 mm 95 mm -55...+80C 2.0 kg/mm 2.1 Nm 1.0 m

Frequency

ELECTRICAL CHARACTERISTICS at +20C Characteristic impedance Return loss 24 dB for 100 m cable with NKC connectors Bands according to customer's specifications 380500 MHz 806960 MHz 17101880 MHz 19002170 MHz Other bands also available on request Attenuation Velocity factor Capacitance Maximum frequency Max power rating Peak RF voltage rating Peak power rating DC resistance Inner conductor Outer conductor see table 0.86 78 pF/m 14 000 MHz see table 1.2 kV 16.1 kW 3.6 /km 3.1 /km 50 1

IEC 60754 -1/-2 halogen free, non corrosive

IEC 60332-3 C fire retardant

JACKETING OPTIONS

RF 3/8"-50 RF 3/8"-50 GHF RF 3/8"-50 BHF RF 3/8"-50 BHF

NKRF03800 NKRF03801 NKRF03802 NKRF03804

Black polyethylene, halogen free Grey, halogen free fire retardant thermoplastic Black, halogen free fire retardant thermoplastic Black, halogen free fire retardant thermoplastic

yes yes yes yes

no yes yes yes

no yes yes yes

yes no yes yes

-40C -5C -5C -5C

10 30 50 88 100 108 174 200 300 400 450 500 512 600 700 800 850 890 900 950 960 1000 1200 1400 1600 1800 1900 2000 2200 2400 2600 2800 3000 3400 6000 13500

1.03 1.79 2.32 3.10 3.31 3.45 4.41 4.74 5.86 6.81 7.25 7.66 7.76 8.44 9.16 9.84 10.2 10.4 10.5 10.8 10.9 11.1 12.3 13.3 14.4 15.3 15.8 16.2 17.1 18.0 18.8 19.6 20.4 21.9 30.4 49.7

Attenuation dB/100 m

7.0 3.9 3.0 2.2 2.1 2.0 1.6 1.5 1.2 1.0 1.0 0.90 0.89 0.82 0.76 0.70 0.68 0.67 0.66 0.64 0.64 0.63 0.57 0.52 0.49 0.46 0.44 0.43 0.41 0.39 0.37 0.36 0.34 0.32 0.23 0.15

STANDARD DRUMCable type Standard drum name P6D Standard length m RF 3/8" 250 Outer diam. cm 60 Outer width cm 51 Drum weight kg 14 Total weight kg 46 Drum freight volume m3 0.18

UV retardancy

IEC 61034 low smoke emission

JACKET

CODE

TYPE

Min. installation temperature

Attenuation values are typical at ambient temperature +20C. Power rating ambient temperature +40C, inner conductor +100C.

(UL) CATVR E205016

6

7

RF 1/2 -5 0

Feeder cable

RF 1/2-50SpecificationsCONSTRUCTION Inner conductor Dielectric Outer conductor Jacketing Marking Copper-clad aluminium wire Cellular polyethylene Corrugated copper tube See table below NK Cables, cable type, manufacture week, year, batch number and meter mark 4.8 mm 12.1 mm 13.9 mm 16.0 mm ATTENUATIONPower rating kW

MECHANICAL CHARACTERISTICS Weight Maximum pulling force Minimum bending radius Single bending Repeated bending Operating temperature range Crush resistance Bending moment Recommended clamp distance 250 kg/km 2550 N 70 mm 120 mm -55...+80C 2.0 kg/mm 3.8 Nm 1.0 m

Frequency

ELECTRICAL CHARACTERISTICS at +20C Characteristic impedance Return loss 24 dB for 100 m cable with NKC connectors Bands according to customer's specifications 380500 MHz 806960 MHz 17101880 MHz 19002170 MHz Other bands also available on request Attenuation Velocity factor Capacitance Maximum frequency Max power rating Peak RF voltage rating Peak power rating DC resistance Inner conductor Outer conductor see table 0.88 76 pF/m 10 000 MHz see table 1.80 kV 31.8 kW 1.43 /km 1.99 /km 50 1

RF 1/2"-50 RF 1/2"-50 GHF RF 1/2"-50 BHF RF 1/2"-50 BHF

NKRF01200 NKRF01201 NKRF01202 NKRF01204

Black polyethylene, halogen free Grey, halogen free fire retardant thermoplastic Black, halogen free fire retardant thermoplastic Black, halogen free fire retardant thermoplastic

yes yes yes yes

no yes yes yes

no yes yes yes

yes no yes yes

-40C -5C -5C -5C

Min. installation temperature

IEC 60754 -1/-2 halogen free, non corrosive

IEC 60332-3 C fire retardant

JACKETING OPTIONS

10 30 50 88 100 108 174 200 300 400 450 500 512 600 700 800 850 890 900 950 960 1000 1200 1400 1600 1800 1900 2000 2200 2400 2600 2800 3000 3400 6000 8800

0.669 1.17 1.51 2.02 2.16 2.25 2.88 3.09 3.83 4.45 4.74 5.01 5.08 5.53 6.01 6.45 6.67 6.84 6.88 7.09 7.13 7.29 8.05 8.77 9.44 10.1 10.4 10.7 11.3 11.9 12.4 12.9 13.5 14.5 20.2 25.5

Attenuation dB/100 m

12 6.9 5.3 4.0 3.7 3.6 2.8 2.6 2.1 1.8 1.7 1.6 1.6 1.4 1.3 1.2 1.2 1.2 1.2 1.1 1.1 1.1 0.99 0.90 0.84 0.79 0.76 0.74 0.70 0.66 0.63 0.61 0.58 0.54 0.39 0.31

STANDARD DRUMCable type Standard drum name P11D Standard length m RF 1/2" 500 Outer diam. cm 114 Outer width cm 55 Drum weight kg 43 Total weight kg 168 Drum freight volume m3 0.71

IEC 61034 low smoke emission

UV retardancy

JACKET

CODE

TYPE

Attenuation values are typical at ambient temperature +20C. Power rating ambient temperature +40C, inner conductor +100C.

(UL) CATVR E205016

8

9

RF 5

/8 -

Feeder cable

50

RF 5/8-50SpecificationsCONSTRUCTION Inner conductor Dielectric Outer conductor Jacketing Marking Copper tube Cellular polyethylene Corrugated copper tube See table below NK Cables, cable type, manufacture week, year, batch number and meter mark 7.0 mm 17.6 mm 19.7 mm 21.9 mm ATTENUATIONPower rating kW

MECHANICAL CHARACTERISTICS Weight M