49
© 9/20/2013 Welcome! PHCC Connect 2013 Re-Piping Made Easy To Diversify Your Business © LLC

PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

  • Upload
    lethien

  • View
    221

  • Download
    3

Embed Size (px)

Citation preview

Page 1: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

©

9/20/2013

Welcome!PHCC Connect 2013

Re-Piping Made Easy To Diversify

Your Business

© LLC

Page 2: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

Agenda

1. Market Summary

2. Statistical Information

3. Re-Piping & Repair Opportunities

4. What Is PEX Tubing

5. Why Does PEX Tubing Make Sense For Re-Piping

6. Codes & Standards

©

6. Codes & Standards

7. Adapting To Existing Plumbing

8. Stub-Out Options

9. Valves & Specialty Boxes

10. Installation Practices

2Friday, September 20, 2013

Page 3: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

Remodel Market Share – Interviews/Focus Groups

Newport Partners conducted interviews with distributors, focus groups with plumbers, and interviews with plumbers from across the country.

2

2

11

1 2Interviews were conducted with 32

©

3Friday, September 20, 2013

Distributor Interview

LocationsFocus Group

Locations

6 1

1

1

2

2

1

6

2

56

2 2

3

6

# Plumber

Interviews

conducted with 32 distributors.

Four focus groups were held; two in Northern Virginia and two in Cincinnati, OH.

Surveys were conducted with 54 plumbers across the U.S.

Page 4: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

Remodel Market Share – Distributer Findings

Average Share of PEX Market by Sector

40.0%

50.0%

According to their responses, 47% of the PEX sold by interviewed distributors is used in existing homes, with nearly as much sold into new residences.

©

4Friday, September 20, 2013

0.0%

10.0%

20.0%

30.0%

Commercial Residential - New Residential - Existing

Interviews were conducted with 32 distributors.

Page 5: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

Remodel Market Share – New Housing Growth

Housing Starts last Decade (thousands)

©

5Friday, September 20, 2013

2012 Approx. 22% Increase

In New Home Start Ups

2013 Approx. 20% Increase

In New Home Start Ups

Page 6: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

Remodel Market Share – National Project Counts

Estimated number of jobs by job and structure type

5 Job Types

5 structure types

ATotal

Repipe

BPartial Repipe

CRemodels

DAdditions

EAdded Fixture

SF Detached 286,300 1,133,757 4,236,805 376,945 10,280,940

SF Attached 18,600 115,076 435,412 44,605 955,809

2-4 Unit

1

2

©

6Friday, September 20, 2013

2-4 Unit Structure

72,446 214,295 597,842 6,785 1,291,898

5+ Unit Structure

44,048 179,113 1,251,846 31,747 1,905,603

Mobile 16,985 163,947 323,662 18,899 797,215

TOTAL 438,380 1,806,188 6,845,567 478,981 15,231,464

6

3

4

5

Page 7: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

Remodel Market Share – Age of Pipe Modified

Use of Pipe by Age of Housing

% YES YES NO

ADDITIONS All Owners

Before 1950 1.3% 188 13,746 13,934

1950-1959 1.2% 102 8,446 8,548

1960-1969 0.6% 48 8,631 8,679

1970-1979 0.7% 95 12,810 12,906

1980-1989 0.7% 62 9,249 9,311

1990-1999 0.5% 55 10,755 10,810

2000-2011 0.9% 104 11,800 11,904

Total 0.9% 655 75,437 76,091

©

7Friday, September 20, 2013

Total 0.9% 655 75,437 76,091

ADDED / REPLACED FIXTURE All Owners

Before 1950 22.9% 3,191 10,743 13,934

1950-1959 23.7% 2,022 6,525 8,548

1960-1969 23.8% 2,069 6,610 8,679

1970-1979 24.3% 3,142 9,764 12,906

1980-1989 25.6% 2,385 6,926 9,311

1990-1999 25.6% 2,762 8,048 10,810

2000-2011 12.5% 1,483 10,420 11,904

Total 22.4% 17,054 59,037 76,091

Page 8: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

Remodel Market Share – Age of Pipe Modified

Use of Pipe by Age of Housing -- 2011

% YES YES NO

REPIPE (000’s) (000’s) All Owners

Before 1950 5.9% 816 13,119 13,934

1950-1959 5.2% 448 8,099 8,548

1960-1969 5.1% 439 8,240 8,679

1970-1979 4.1% 535 12,371 12,906

1980-1989 3.5% 327 8,984 9,311

1990-1999 2.6% 284 10,527 10,810

2000-2011 1.3% 159 11,745 11,904

©

8Friday, September 20, 2013

2000-2011 1.3% 159 11,745 11,904

Total 4.0% 3,006 73,085 76,091

REMODEL All Owners

Before 1950 11.0% 1,539 12,395 13,934

1950-1959 10.5% 901 7,646 8,548

1960-1969 11.2% 970 7,709 8,679

1970-1979 11.3% 1,460 11,445 12,906

1980-1989 11.3% 1,054 8,257 9,311

1990-1999 8.3% 900 9,910 10,810

2000-2011 3.8% 447 11,457 11,904

Total 9.6% 7,272 68,819 76,091

These are jobs reported by owners for the 2 years prior to the 2011 AHS.

Page 9: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

©

9Friday, September 20, 2013

Page 10: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

What is PEX

• PEX was developed in the 1960’s

in Germany and has been used in

plumbing applications for over 30

years in Europe

• Through one of three processes,

©

10Friday, September 20, 2013

• Through one of three processes,

High Density Polyethylene

undergoes a change to produce a

three dimensional link.

• This makes PEX stable for higher

temperature applications such as

plumbing and radiant heating.

Page 11: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

Scaling and Corrosion free

Solder free

Light

PEPE

Scaling and corrosion free

Solder free

Light

Flexible PEXPEX

Advantages of PEX

©

11Friday, September 20, 2013

Light

Flexible

Resistant to chemicals

Sanitary

PEPEFlexible

Resistant to chemicals

Sanitary

PEXPEX

Temperature resistant to 200°°°°F

Resistant to high pressure

Resistant to stress cracking

+++

Page 12: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

THE ADVANTAGES OF RE-PIPING WITH PEX TUBING

©

12Friday, September 20, 2013

Page 13: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

PEX TUBING IS AVAILABLE IN COILS & STRAIGHT LENGTHS

©

13Friday, September 20, 2013

Page 14: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

PEX Composite Tubing & (PEX-AL-PEX)

All of the advantages and

features of PEX plus…

• Form stable capability

• Extended UV Resistance

• Professional appearance

PE

Adhesive

Adhesive

©

14Friday, September 20, 2013

• Professional appearance

• Low expansion coefficient

• Easy to snake in walls & ceilings

PEX

Aluminum

Page 15: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

PEX Composite Tubing

• Available in coils and straight lengths

• Standard and metric sizes

• Some work with same PEX fittings

©

15Friday, September 20, 2013

Page 16: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

PEX Connections

Plumbing Fittings and Manifolds

• 90’s, Tee’s, couplings

• Reducers, threaded and sweat adapters

• Copper fixture stub – outs

• Fixture stops and adapters

• PEX x Copper adapters

©

16Friday, September 20, 2013

• PEX x Copper adapters

• Manifolds

• Ice Maker & Laundry outlet boxes with valves

Page 17: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

PEX COMPLIANCE TO ALL MODEL PLUMBING CODES

©

17Friday, September 20, 2013

Page 18: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

Material Selection

Reduction of Lead in Drinking Water Act

Timeline

• Bill signed January 4, 2011

• Implementation January 4, 2014

Amends the Safe Drinking Water Act

New ZERO LEAD Requirements

©

Amends the Safe Drinking Water Act

The amended definition of “lead free” is provided

• 0.20% max lead for solder and flux

• 0.25% max lead for products by weighted average

• Multiple component products are calculated to address total

wetted exposure based upon wetted surface area of each

component and that component’s lead content by percentage

9/20/2013

Page 19: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

PEX Tubing Installation Practices

Water Heaters and Other Heat Sources

• DO NOT connect directly to gas fired hot water heater

• Check With Local Codes Regarding Connecting To Gas Water Heaters

©

19Friday, September 20, 2013

Maintain a minimum of

6 inches of clearance

from gas heater vents

Minimum of 12 inches of vertical heat sources like

recessed lights and appliance or heater vents

Page 20: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

PEX Tubing Installation Practices

Concrete Installation

• Use plastic elbow sleeves when exiting slab

• Protect tubing via sleeving

when passing through

expansion joints

©

20Friday, September 20, 2013

• Fasten tubing every 2-3 feet to

wire mesh

• Protect the PEX tubing with

non-metallic sleeving material

where it enters and/or exits a

slab. (PEX need not be

sleeved its entire length.)

Page 21: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

Water Hammer, Grounding, Pressure Testing

Water Hammer

• PEX tubing reduces the tendency for water hammers, and

helps prevent damage that might be caused by these

pressure changes.

• Arrestors are still advisable in situations where rapid flow

stoppage may occur or when required by code

Grounding

©

21Friday, September 20, 2013

Grounding

• Neither PEX nor aluminum PEX products may be used as

electrical ground

Pressure Testing

• The system must be pressure tested in accordance with

local codes or at least at working pressure (within tubing

limits)

Page 22: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

PEX Adapters (Connecting To Existing Plumbing)

©

22Friday, September 20, 2013

Page 23: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

PEX Stub Out Options

• Drop ear elbow

• Snap-in bend support with brackets

©

23Friday, September 20, 2013

• Drop ear bend support

• Plastic Bend Supports

Page 24: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

PEX To Copper Stub-Out Connections

©

24Friday, September 20, 2013

Page 25: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

Water Closet / Faucet Finish Options

©

25Friday, September 20, 2013

Page 26: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

Additional Stub-Out Methods

©

26Friday, September 20, 2013

Page 27: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

PEX Ball Valve & Wall Hydrants

©

27Friday, September 20, 2013

Page 28: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

PEX Washing Machine & Ice Maker Outlet Boxes

©

28Friday, September 20, 2013

Page 29: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

Installation Methods

Higher

Traditional Branch and Tee System

©

29Friday, September 20, 2013

Inaccessible connections in wall

Higher pressure drop

Significant pressure/temperature swings

More fittings, less tubing

Increased labor

Page 30: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

BRANCH & TEE PIPING DESIGN

©

30Friday, September 20, 2013

Page 31: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

Combination Manifold / Branch and Tee System

Installation Methods

©

31Friday, September 20, 2013

Reduced pressure/temperature swings than Traditional

Reduced inaccessible connections in wall

Page 32: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

Combination Manifold Piping Design

©

32Friday, September 20, 2013

Page 33: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

Copper & Poly Manifolds / Flow Through Manifolds

©

33Friday, September 20, 2013

Page 34: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

Manifold With Valves

• Access Panels Typically Required

©

34Friday, September 20, 2013

Page 35: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

Low pressure

Conserves water

Home Run Manifold Or Parallel System

Installation Methods

©

35Friday, September 20, 2013

Continuous run, No fittings in wall

Low pressure drop

No pressure/temperature swings

Fewer fittings, more tubing

Page 36: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

Home Run System Piping Design

©

36Friday, September 20, 2013

Page 37: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

How Does The Home Run System Work?

• It’s uses a centrally located

manifold with individual

shut-off valves to supply

each fixture with dedicated

distribution lines.

• PEX distribution lines run to

©

37Friday, September 20, 2013

• PEX distribution lines run to

each fixture in a “home-run”

system.

• A large reservoir in each

side of the manifold helps

maintain equal pressure

Page 38: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

• Appropriately-sized lines can be installed so hot water is delivered faster. (3/8” and 1/2”)

• Less water is wasted while purging

How Does the Home Run System Work?

©

38Friday, September 20, 2013

• Less water is wasted while purging these lines.

• Reduce water and energy waste by up to 40%

• By providing each fixture with its own distribution line, the system out-performs conventional plumbing designs.

Page 39: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

Home Run Display

©

39Friday, September 20, 2013

Page 40: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

Home Run System

Hot Water Recirculation Systems

©

40Friday, September 20, 2013

Remote ManifoldSystem

Page 41: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

Large Uncoilers Typically Handle 100 ft. – 500 ft. Coils

©

41Friday, September 20, 2013

Page 42: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

©

42Friday, September 20, 2013

Page 43: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

Some PEX Tubing Is Available On Spools

©

43Friday, September 20, 2013

Page 44: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

Attic Re-Piping Installation

©

44Friday, September 20, 2013

Page 45: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

Contractor Pulling Multiple Lines At A Time ( Hot & Cold)

©

45Friday, September 20, 2013

Page 46: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

Pulling PEX Tubing Lines From The Attic To The Fixture With An Electrical Wire Snake

©

46Friday, September 20, 2013

Page 47: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

Connecting To Existing Fixtures

©

47Friday, September 20, 2013

Minimum Damage To Existing Finished Walls

Page 48: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

Connecting To Existing Copper

©

48Friday, September 20, 2013

Page 49: PHCC Connect 2013 Welcome! Re-Piping Made Easy To …s3.amazonaws.com/rdcms-phcc/files/production/public/2011Foundatio… · Plumbing Fittings and Manifolds • 90’s, Tee’s, couplings

©

49Friday, September 20, 2013