Upload
others
View
19
Download
1
Embed Size (px)
Citation preview
PDF SUMMARY OF PROTECTIVE GLASSES
DEKA System Protective Glasses
Product Name Source Normal or Blind glasses Shielded Wavelength Protection level* CODE
Dermobeam 2000 DYE Normal glasses 575-595 D LB6 + I LB7 070100053
Dermobeam 2000 DYE Normal glasses
190-315 315-14001400-3300
10600
D L9 + IR L4D L7 + I L9 + R L8
DI L5DI L5
070100054
Dot 1540 Er:Glass Normal glasses
900-1000>1000-1030>1030-1400>1400-1800 2100- 3000
DIR L5DIR L7
D L7 IRL8DI L5 DI L5
070100044
Dot 1540 FT Normal glasses - Compliant with DIN EN 166 for Intens Pulse Light 070100024
Dot 1540 FT Blind glasses
190-315 315-14001400-3300
10600
D L9 + IR L4D L7 + I L9 + R L8
DI L5DI L5
070100054
Dot 1540 Nd:YAP Normal glasses
900-1000>1000-1030>1030-1400>1400-1800 2100- 3000
DIR L5DIR L7
D L7 IRL8DI L5 DI L5
070100044
Dot 1540 SA Normal glasses - Compliant with DIN EN 166 for Intens Pulse Light 070100024
Duolite QS KTP Normal glasses
190-315>315-532808-<890890-<940940-<980980-1065
D L8 + IR L4DIR L6 + M L6
DIR L3DIR L4DIR L5
DM L6 + IR L7
070001076
PROTECTIVE GLASSES
PROTECTIVE GLASSES
PDF SUMMARY OF PROTECTIVE GLASSES
DEKA System Protective Glasses
Product Name Source Normal or Blind glasses Shielded Wavelength Protection level* CODE
Duolite QS KTP QS Blind glasses
190-315 315-14001400-3300
10600
D L9 + IR L4D L7 + I L9 + R L8
DI L5DI L5
070100054
Duolite QS Nd:YAG QS Normal glasses
190-315>315-532808-<890890-<940940-<980980-1065
D L8 + IR L4DIR L6 + M L6
DIR L3DIR L4DIR L5
DM L6 + IR L7
070001076
Duolite QS Nd:YAG QS Blind glasses
190-315 315-14001400-3300
10600
D L9 + IR L4D L7 + I L9 + R L8
DI L5DI L5
070100054
Excilite Micro MEL@308 Normal glasses 180-315>315-532
D L7 + R L4D L4 + IR L6 070100025
Minisilk FT FT Normal glasses - Compliant with DIN EN 166 for Intens Pulse Light 070100024
Minisilk FT FT Blind glasses
190-315 315-14001400-3300
10600
D L9 + IR L4D L7 + I L9 + R L8
DI L5DI L5
070100054
Neurolas CO2 Normal glasses 10600 DI L3 070100008
Photosilk UPL Normal glasses - Compliant with DIN EN 166 for Intens Pulse Light 070100024
Photosilk UPL Blind glasses
190-315 315-14001400-3300
10600
D L9 + IR L4D L7 + I L9 + R L8
DI L5DI L5
070100054
PROTECTIVE GLASSES
PDF SUMMARY OF PROTECTIVE GLASSES
DEKA System Protective Glasses
Product Name Source Normal or Blind glasses Shielded Wavelength Protection level* CODE
Photosilk Plus Er:YAG Normal glasses 2800-30002940
D L4 + I L5 DI L5 070100018
Photosilk Plus Nd:YAG LP Normal glasses 1030-1100 DL8 + IL9 + RL8 070100049
Photosilk Plus UPL Normal glasses - Compliant with DIN EN 166 for Intens Pulse Light 070100024
Photosilk Plus UPL Blind glasses
190-315 315-14001400-3300
10600
D L9 + IR L4D L7 + I L9 + R L8
DI L5DI L5
070100054
Smart 2100 + Ho:YAG Normal glasses
980-10501064
1400-220010600
DIL4DIR L5
D L4 + I L5DL5 + I L6
070100015
Smart 2940 Plus Er:YAG Normal glasses 2800-30002940
D L4 + I L5 DI L5 070100018
Smart 2940D Plus Er:YAG Normal glasses 2800-30002940
D L4 + I L5 DI L5 070100018
Smart 980_5 Diode Normal glasses
770-800>800-1100>800-980>980-1065
>1065-1100
DIR L4D L5IR L6IR L7IR L5
070100043
Smart US20D CO2 Normal glasses 10600 DI L3 070100008
Smartepil LS Nd:YAG LP Normal glasses 1064 DIR L7 070100004
PROTECTIVE GLASSES
PDF SUMMARY OF PROTECTIVE GLASSES
DEKA System Protective Glasses
Product Name Source Normal or Blind glasses Shielded Wavelength Protection level* CODE
SmartFile Nd:YAG SP Normal glasses
760-790>790-805>805-840>840-860>860-1030
>1030-1065>1065-1075>1075-1085>1085-1100
DIR L2DIR L3DIR L4DIR L5
D L5 + R L6DL5 + IRL7DL5 + IRL6
DIR L5DIR L3
070100054
Smartlipo Nd:YAG SP Normal glasses
760-790>790-805>805-840>840-860>860-1030
>1030-1065>1065-1075>1075-1085>1085-1100
DIR L2DIR L3DIR L4DIR L5
D L5 + R L6DL5 + IRL7DL5 + IRL6
DIR L5DIR L3
070100045
SmartLite KTP Normal glasses 180-315>315-532
D L9 + I L3DI L5 070100029
SmartLite Derma KTP Normal glasses 180-315>315-532
D L9 + I L3DI L5 070100029
SmartXide DOT CO2 Blind glasses
190-315 315-14001400-3300
10600
D L9 + IR L4D L7 + I L9 + R L8
DI L5DI L5
070100054
SmartXide DOT CO2 Normal glasses 10600 DI L4 070100038
SmartXide HS 30W CO2 Blind glasses
190-315 315-14001400-3300
10600
D L9 + IR L4D L7 + I L9 + R L8
DI L5DI L5
070100054
PROTECTIVE GLASSES
PDF SUMMARY OF PROTECTIVE GLASSES
DEKA System Protective Glasses
Product Name Source Normal or Blind glasses Shielded Wavelength Protection level* CODE
SmartXide HS 30W CO2 Blind glasses 10600 DI L4 070100038
SmartXide HS 50W CO2 Blind glasses
190-315 315-14001400-3300
10600
D L9 + IR L4D L7 + I L9 + R L8
DI L5DI L5
070100054
SmartXide HS 50W CO2 Normal glasses 10600 DI L5 070100047
Smarty A-10 Nd:YAG SP Normal glasses
760-790>790-805>805-840>840-860>860-1030
>1030-1065>1065-1075>1075-1085>1085-1100
DIR L2DIR L3DIR L4DIR L5
D L5 + R L6DL5 + IRL7DL5 + IRL6
DIR L5DIR L3
070100045
Stimul 1340 Nd:YAP Normal glasses
900-1000>1000-1030>1030-1400>1400-1800 2100- 3000
DIR L5DIR L7
D L7 IRL8DI L5 DI L5
070100044
Synchro FT FT Normal glasses - Compliant with DIN EN 166 for Intens Pulse Light 070100024
Synchro FT FT Blind glasses
190-315 315-14001400-3300
10600
D L9 + IR L4D L7 + I L9 + R L8
DI L5DI L5
070100054
Synchro FT Nd:YAG LP Normal glasses 1030-1100 DL8 + IL9 + RL8 070100049
Synchro FT Nd:YAG LP Blind glasses
190-315 315-14001400-3300
10600
D L9 + IR L4D L7 + I L9 + R L8
DI L5DI L5
070100054
PROTECTIVE GLASSES
PDF SUMMARY OF PROTECTIVE GLASSES
DEKA System Protective Glasses
Product Name Source Normal or Blind glasses Shielded Wavelength Protection level* CODE
Synchro HP Er:YAG Normal glasses 2800-30002940
D L4 + I L5 DI L5 070100018
Synchro HP Nd:YAG LP Normal glasses 1030-1100 DL8 + IL9 + RL8 070100049
Synchro HP Nd:YAG LP Blind glasses
190-315 315-14001400-3300
10600
D L9 + IR L4D L7 + I L9 + R L8
DI L5DI L5
070100054
Synchro HP UPL Normal glasses - Compliant with DIN EN 166 for Intens Pulse Light 070100024
Synchro HP UPL Blind glasses
190-315 315-14001400-3300
10600
D L9 + IR L4D L7 + I L9 + R L8
DI L5DI L5
070100054
Synchro PLA:Y Alex Blind glasses
190-315 315-14001400-3300
10600
D L9 + IR L4D L7 + I L9 + R L8
DI L5DI L5
070100054
Synchro PLA:Y Alex Normal glasses - - 070001199
Synchro PLA:Y FT Normal glasses - Compliant with DIN EN 166 for Intens Pulse Light 070100024
Synchro PLA:Y FT Blind glasses
190-315 315-14001400-3300
10600
D L9 + IR L4D L7 + I L9 + R L8
DI L5DI L5
070100054
Synchro PLA:Y Nd:YAG LP Blind glasses
190-315 315-14001400-3300
10600
D L9 + IR L4D L7 + I L9 + R L8
DI L5DI L5
070100054
Synchro PLA:Y Nd:YAG LP Normal glasses 1030-1100 DL8 + IL9 + RL8 070100049
PROTECTIVE GLASSES
PDF SUMMARY OF PROTECTIVE GLASSES
DEKA System Protective Glasses
Product Name Source Normal or Blind glasses Shielded Wavelength Protection level* CODE
Triactive+ Diode Normal glasses
760-790>790-805>805-840>840-860>860-1030
>1030-1065>1065-1075>1075-1085>1085-1100
DIR L2DIR L3DIR L4DIR L5
D L5 + R L6DL5 + IRL7DL5 + IRL6
DIR L5DIR L3
070100045
Triactive+ Diode Blind glasses
190-315 315-14001400-3300
10600
D L9 + IR L4D L7 + I L9 + R L8
DI L5DI L5
070100054
PROTECTIVE GLASSES
PDF SUMMARY OF PROTECTIVE GLASSES
LEGEND
Product Name The name of the DEKA system which has the glasses included in the supply.
Source The source of the DEKA system whose wavelength is shielded by the protective glass.
Normal or Blind glasses Normal glasses can be used by the practitioner for the treatment or by the patient. Blind glasses are only for patients.
Shielded Wavelength The wavelengths or spectrum that the safety glasses can shield.
Protection level* The levels of the protection of the glasses for the different wavelengths or spectrum, according to the European Norm EN 207 (see the table below).
CODE This is the DEKA code that must be used to order the protective glasses.
PROTECTIVE GLASSES
PDF SUMMARY OF PROTECTIVE GLASSES
*EN 207 LABEL
Is composed by one or more linees. Each one of them descrive the protection level of the filter against a single wavelength or against a spectrum of wavelengths. It is composed by 3 parts:
1) Shilded wavelengths. The single wavelength (in nanometers) or the
spectrum that is shilded.
2) Stability tests passed. 3) Scale Number Ln, is the “Scale Number”.
“n” is the number that represent the lower limit for optical density. In example: L6 means that OD>6
Stability test conditions for filters and eye protection against laser radiation. Reference EN 207
Laser working mode Letter
Continuous wave laser (More than 250 μs)
D
Pulsed laser (from 1 μs to 250 μs)
I
Q Switched pulsed laser (From 1 ns to 1 μs)
R
Mode-locked pulsed laser (Less than 1 ns)
M
Example of labels: 315-980 D L5 From 315 nm to 980 nm, for laser in continuous mode, OD is >5
1064 D L6 + IR L7 At 1064 nm, with laser in continuous mode OD is >6 and with laser in pulsed mode or in a q-switched mode, OD is >7