9
PDF SUMMARY OF PROTECTIVE GLASSES DEKA System Protective Glasses Product Name Source Normal or Blind glasses Shielded Wavelength Protection level* CODE Dermobeam 2000 DYE Normal glasses 575-595 D LB6 + I LB7 070100053 Dermobeam 2000 DYE Normal glasses 190-315 315-1400 1400-3300 10600 D L9 + IR L4 D L7 + I L9 + R L8 DI L5 DI L5 070100054 Dot 1540 Er:Glass Normal glasses 900-1000 >1000-1030 >1030-1400 >1400-1800 2100- 3000 DIR L5 DIR L7 D L7 IRL8 DI L5 DI L5 070100044 Dot 1540 FT Normal glasses - Compliant with DIN EN 166 for Intens Pulse Light 070100024 Dot 1540 FT Blind glasses 190-315 315-1400 1400-3300 10600 D L9 + IR L4 D L7 + I L9 + R L8 DI L5 DI L5 070100054 Dot 1540 Nd:YAP Normal glasses 900-1000 >1000-1030 >1030-1400 >1400-1800 2100- 3000 DIR L5 DIR L7 D L7 IRL8 DI L5 DI L5 070100044 Dot 1540 SA Normal glasses - Compliant with DIN EN 166 for Intens Pulse Light 070100024 Duolite QS KTP Normal glasses 190-315 >315-532 808-<890 890-<940 940-<980 980-1065 D L8 + IR L4 DIR L6 + M L6 DIR L3 DIR L4 DIR L5 DM L6 + IR L7 070001076 PROTECTIVE GLASSES

PDF SUMMARY OF PROTECTIVE GLASSES - DEKA...D L8 + IR L4 DIR L6 + M L6 DIR L3 DIR L4 DIR L5 DM L6 + IR L7 070001076 Duolite QS Nd:YAG QS Blind glasses 190-315 315-1400 1400-3300 10600

  • Upload
    others

  • View
    19

  • Download
    1

Embed Size (px)

Citation preview

Page 1: PDF SUMMARY OF PROTECTIVE GLASSES - DEKA...D L8 + IR L4 DIR L6 + M L6 DIR L3 DIR L4 DIR L5 DM L6 + IR L7 070001076 Duolite QS Nd:YAG QS Blind glasses 190-315 315-1400 1400-3300 10600

PDF SUMMARY OF PROTECTIVE GLASSES

DEKA System Protective Glasses

Product Name Source Normal or Blind glasses Shielded Wavelength Protection level* CODE

Dermobeam 2000 DYE Normal glasses 575-595 D LB6 + I LB7 070100053

Dermobeam 2000 DYE Normal glasses

190-315 315-14001400-3300

10600

D L9 + IR L4D L7 + I L9 + R L8

DI L5DI L5

070100054

Dot 1540 Er:Glass Normal glasses

900-1000>1000-1030>1030-1400>1400-1800 2100- 3000

DIR L5DIR L7

D L7 IRL8DI L5 DI L5

070100044

Dot 1540 FT Normal glasses - Compliant with DIN EN 166 for Intens Pulse Light 070100024

Dot 1540 FT Blind glasses

190-315 315-14001400-3300

10600

D L9 + IR L4D L7 + I L9 + R L8

DI L5DI L5

070100054

Dot 1540 Nd:YAP Normal glasses

900-1000>1000-1030>1030-1400>1400-1800 2100- 3000

DIR L5DIR L7

D L7 IRL8DI L5 DI L5

070100044

Dot 1540 SA Normal glasses - Compliant with DIN EN 166 for Intens Pulse Light 070100024

Duolite QS KTP Normal glasses

190-315>315-532808-<890890-<940940-<980980-1065

D L8 + IR L4DIR L6 + M L6

DIR L3DIR L4DIR L5

DM L6 + IR L7

070001076

PROTECTIVE GLASSES

Page 2: PDF SUMMARY OF PROTECTIVE GLASSES - DEKA...D L8 + IR L4 DIR L6 + M L6 DIR L3 DIR L4 DIR L5 DM L6 + IR L7 070001076 Duolite QS Nd:YAG QS Blind glasses 190-315 315-1400 1400-3300 10600

PROTECTIVE GLASSES

PDF SUMMARY OF PROTECTIVE GLASSES

DEKA System Protective Glasses

Product Name Source Normal or Blind glasses Shielded Wavelength Protection level* CODE

Duolite QS KTP QS Blind glasses

190-315 315-14001400-3300

10600

D L9 + IR L4D L7 + I L9 + R L8

DI L5DI L5

070100054

Duolite QS Nd:YAG QS Normal glasses

190-315>315-532808-<890890-<940940-<980980-1065

D L8 + IR L4DIR L6 + M L6

DIR L3DIR L4DIR L5

DM L6 + IR L7

070001076

Duolite QS Nd:YAG QS Blind glasses

190-315 315-14001400-3300

10600

D L9 + IR L4D L7 + I L9 + R L8

DI L5DI L5

070100054

Excilite Micro MEL@308 Normal glasses 180-315>315-532

D L7 + R L4D L4 + IR L6 070100025

Minisilk FT FT Normal glasses - Compliant with DIN EN 166 for Intens Pulse Light 070100024

Minisilk FT FT Blind glasses

190-315 315-14001400-3300

10600

D L9 + IR L4D L7 + I L9 + R L8

DI L5DI L5

070100054

Neurolas CO2 Normal glasses 10600 DI L3 070100008

Photosilk UPL Normal glasses - Compliant with DIN EN 166 for Intens Pulse Light 070100024

Photosilk UPL Blind glasses

190-315 315-14001400-3300

10600

D L9 + IR L4D L7 + I L9 + R L8

DI L5DI L5

070100054

Page 3: PDF SUMMARY OF PROTECTIVE GLASSES - DEKA...D L8 + IR L4 DIR L6 + M L6 DIR L3 DIR L4 DIR L5 DM L6 + IR L7 070001076 Duolite QS Nd:YAG QS Blind glasses 190-315 315-1400 1400-3300 10600

PROTECTIVE GLASSES

PDF SUMMARY OF PROTECTIVE GLASSES

DEKA System Protective Glasses

Product Name Source Normal or Blind glasses Shielded Wavelength Protection level* CODE

Photosilk Plus Er:YAG Normal glasses 2800-30002940

D L4 + I L5 DI L5 070100018

Photosilk Plus Nd:YAG LP Normal glasses 1030-1100 DL8 + IL9 + RL8 070100049

Photosilk Plus UPL Normal glasses - Compliant with DIN EN 166 for Intens Pulse Light 070100024

Photosilk Plus UPL Blind glasses

190-315 315-14001400-3300

10600

D L9 + IR L4D L7 + I L9 + R L8

DI L5DI L5

070100054

Smart 2100 + Ho:YAG Normal glasses

980-10501064

1400-220010600

DIL4DIR L5

D L4 + I L5DL5 + I L6

070100015

Smart 2940 Plus Er:YAG Normal glasses 2800-30002940

D L4 + I L5 DI L5 070100018

Smart 2940D Plus Er:YAG Normal glasses 2800-30002940

D L4 + I L5 DI L5 070100018

Smart 980_5 Diode Normal glasses

770-800>800-1100>800-980>980-1065

>1065-1100

DIR L4D L5IR L6IR L7IR L5

070100043

Smart US20D CO2 Normal glasses 10600 DI L3 070100008

Smartepil LS Nd:YAG LP Normal glasses 1064 DIR L7 070100004

Page 4: PDF SUMMARY OF PROTECTIVE GLASSES - DEKA...D L8 + IR L4 DIR L6 + M L6 DIR L3 DIR L4 DIR L5 DM L6 + IR L7 070001076 Duolite QS Nd:YAG QS Blind glasses 190-315 315-1400 1400-3300 10600

PROTECTIVE GLASSES

PDF SUMMARY OF PROTECTIVE GLASSES

DEKA System Protective Glasses

Product Name Source Normal or Blind glasses Shielded Wavelength Protection level* CODE

SmartFile Nd:YAG SP Normal glasses

760-790>790-805>805-840>840-860>860-1030

>1030-1065>1065-1075>1075-1085>1085-1100

DIR L2DIR L3DIR L4DIR L5

D L5 + R L6DL5 + IRL7DL5 + IRL6

DIR L5DIR L3

070100054

Smartlipo Nd:YAG SP Normal glasses

760-790>790-805>805-840>840-860>860-1030

>1030-1065>1065-1075>1075-1085>1085-1100

DIR L2DIR L3DIR L4DIR L5

D L5 + R L6DL5 + IRL7DL5 + IRL6

DIR L5DIR L3

070100045

SmartLite KTP Normal glasses 180-315>315-532

D L9 + I L3DI L5 070100029

SmartLite Derma KTP Normal glasses 180-315>315-532

D L9 + I L3DI L5 070100029

SmartXide DOT CO2 Blind glasses

190-315 315-14001400-3300

10600

D L9 + IR L4D L7 + I L9 + R L8

DI L5DI L5

070100054

SmartXide DOT CO2 Normal glasses 10600 DI L4 070100038

SmartXide HS 30W CO2 Blind glasses

190-315 315-14001400-3300

10600

D L9 + IR L4D L7 + I L9 + R L8

DI L5DI L5

070100054

Page 5: PDF SUMMARY OF PROTECTIVE GLASSES - DEKA...D L8 + IR L4 DIR L6 + M L6 DIR L3 DIR L4 DIR L5 DM L6 + IR L7 070001076 Duolite QS Nd:YAG QS Blind glasses 190-315 315-1400 1400-3300 10600

PROTECTIVE GLASSES

PDF SUMMARY OF PROTECTIVE GLASSES

DEKA System Protective Glasses

Product Name Source Normal or Blind glasses Shielded Wavelength Protection level* CODE

SmartXide HS 30W CO2 Blind glasses 10600 DI L4 070100038

SmartXide HS 50W CO2 Blind glasses

190-315 315-14001400-3300

10600

D L9 + IR L4D L7 + I L9 + R L8

DI L5DI L5

070100054

SmartXide HS 50W CO2 Normal glasses 10600 DI L5 070100047

Smarty A-10 Nd:YAG SP Normal glasses

760-790>790-805>805-840>840-860>860-1030

>1030-1065>1065-1075>1075-1085>1085-1100

DIR L2DIR L3DIR L4DIR L5

D L5 + R L6DL5 + IRL7DL5 + IRL6

DIR L5DIR L3

070100045

Stimul 1340 Nd:YAP Normal glasses

900-1000>1000-1030>1030-1400>1400-1800 2100- 3000

DIR L5DIR L7

D L7 IRL8DI L5 DI L5

070100044

Synchro FT FT Normal glasses - Compliant with DIN EN 166 for Intens Pulse Light 070100024

Synchro FT FT Blind glasses

190-315 315-14001400-3300

10600

D L9 + IR L4D L7 + I L9 + R L8

DI L5DI L5

070100054

Synchro FT Nd:YAG LP Normal glasses 1030-1100 DL8 + IL9 + RL8 070100049

Synchro FT Nd:YAG LP Blind glasses

190-315 315-14001400-3300

10600

D L9 + IR L4D L7 + I L9 + R L8

DI L5DI L5

070100054

Page 6: PDF SUMMARY OF PROTECTIVE GLASSES - DEKA...D L8 + IR L4 DIR L6 + M L6 DIR L3 DIR L4 DIR L5 DM L6 + IR L7 070001076 Duolite QS Nd:YAG QS Blind glasses 190-315 315-1400 1400-3300 10600

PROTECTIVE GLASSES

PDF SUMMARY OF PROTECTIVE GLASSES

DEKA System Protective Glasses

Product Name Source Normal or Blind glasses Shielded Wavelength Protection level* CODE

Synchro HP Er:YAG Normal glasses 2800-30002940

D L4 + I L5 DI L5 070100018

Synchro HP Nd:YAG LP Normal glasses 1030-1100 DL8 + IL9 + RL8 070100049

Synchro HP Nd:YAG LP Blind glasses

190-315 315-14001400-3300

10600

D L9 + IR L4D L7 + I L9 + R L8

DI L5DI L5

070100054

Synchro HP UPL Normal glasses - Compliant with DIN EN 166 for Intens Pulse Light 070100024

Synchro HP UPL Blind glasses

190-315 315-14001400-3300

10600

D L9 + IR L4D L7 + I L9 + R L8

DI L5DI L5

070100054

Synchro PLA:Y Alex Blind glasses

190-315 315-14001400-3300

10600

D L9 + IR L4D L7 + I L9 + R L8

DI L5DI L5

070100054

Synchro PLA:Y Alex Normal glasses - - 070001199

Synchro PLA:Y FT Normal glasses - Compliant with DIN EN 166 for Intens Pulse Light 070100024

Synchro PLA:Y FT Blind glasses

190-315 315-14001400-3300

10600

D L9 + IR L4D L7 + I L9 + R L8

DI L5DI L5

070100054

Synchro PLA:Y Nd:YAG LP Blind glasses

190-315 315-14001400-3300

10600

D L9 + IR L4D L7 + I L9 + R L8

DI L5DI L5

070100054

Synchro PLA:Y Nd:YAG LP Normal glasses 1030-1100 DL8 + IL9 + RL8 070100049

Page 7: PDF SUMMARY OF PROTECTIVE GLASSES - DEKA...D L8 + IR L4 DIR L6 + M L6 DIR L3 DIR L4 DIR L5 DM L6 + IR L7 070001076 Duolite QS Nd:YAG QS Blind glasses 190-315 315-1400 1400-3300 10600

PROTECTIVE GLASSES

PDF SUMMARY OF PROTECTIVE GLASSES

DEKA System Protective Glasses

Product Name Source Normal or Blind glasses Shielded Wavelength Protection level* CODE

Triactive+ Diode Normal glasses

760-790>790-805>805-840>840-860>860-1030

>1030-1065>1065-1075>1075-1085>1085-1100

DIR L2DIR L3DIR L4DIR L5

D L5 + R L6DL5 + IRL7DL5 + IRL6

DIR L5DIR L3

070100045

Triactive+ Diode Blind glasses

190-315 315-14001400-3300

10600

D L9 + IR L4D L7 + I L9 + R L8

DI L5DI L5

070100054

Page 8: PDF SUMMARY OF PROTECTIVE GLASSES - DEKA...D L8 + IR L4 DIR L6 + M L6 DIR L3 DIR L4 DIR L5 DM L6 + IR L7 070001076 Duolite QS Nd:YAG QS Blind glasses 190-315 315-1400 1400-3300 10600

PROTECTIVE GLASSES

PDF SUMMARY OF PROTECTIVE GLASSES

LEGEND

Product Name The name of the DEKA system which has the glasses included in the supply.

Source The source of the DEKA system whose wavelength is shielded by the protective glass.

Normal or Blind glasses Normal glasses can be used by the practitioner for the treatment or by the patient. Blind glasses are only for patients.

Shielded Wavelength The wavelengths or spectrum that the safety glasses can shield.

Protection level* The levels of the protection of the glasses for the different wavelengths or spectrum, according to the European Norm EN 207 (see the table below).

CODE This is the DEKA code that must be used to order the protective glasses.

Page 9: PDF SUMMARY OF PROTECTIVE GLASSES - DEKA...D L8 + IR L4 DIR L6 + M L6 DIR L3 DIR L4 DIR L5 DM L6 + IR L7 070001076 Duolite QS Nd:YAG QS Blind glasses 190-315 315-1400 1400-3300 10600

PROTECTIVE GLASSES

PDF SUMMARY OF PROTECTIVE GLASSES

*EN 207 LABEL

Is composed by one or more linees. Each one of them descrive the protection level of the filter against a single wavelength or against a spectrum of wavelengths. It is composed by 3 parts:

1) Shilded wavelengths. The single wavelength (in nanometers) or the

spectrum that is shilded.

2) Stability tests passed. 3) Scale Number Ln, is the “Scale Number”.

“n” is the number that represent the lower limit for optical density. In example: L6 means that OD>6

Stability test conditions for filters and eye protection against laser radiation. Reference EN 207

Laser working mode Letter

Continuous wave laser (More than 250 μs)

D

Pulsed laser (from 1 μs to 250 μs)

I

Q Switched pulsed laser (From 1 ns to 1 μs)

R

Mode-locked pulsed laser (Less than 1 ns)

M

Example of labels: 315-980 D L5 From 315 nm to 980 nm, for laser in continuous mode, OD is >5

1064 D L6 + IR L7 At 1064 nm, with laser in continuous mode OD is >6 and with laser in pulsed mode or in a q-switched mode, OD is >7