Patton Hermetic Condensing Units

  • View
    226

  • Download
    8

Embed Size (px)

DESCRIPTION

Patton reciprocating hermetic condensing units featuring Copeland compressors. From 1.0 to 5.0 Hp and suitable for R134a & R404A.

Transcript

  • www.pattonnz.com www.pattonau.com

    Patton Hermetic Condensing Units

  • Air CooledCondensing Units

    n Reliable and efficient Copeland

    reciprocating hermetic compressors

    n Generous wide finned, low noise level

    condensers supplied with protective

    coil coating

    n Wide range of factory fitted

    accessories available

    n Specifically designed for

    Australasian conditions

    www.pattonnz.com

    CCN Low / Medium

    CC

    N L

    OW

    /ME

    D

    1 3.3 hp

    MODEL Nom. Refrigerant Evaporating Temp C hp -30 -25 -20 -15 -10 -5 0 5

    CCNS100 1.0 R134a 750 1120 1550 2090 2690 3260

    R404A 660 1230 1650 2040 2550

    CCNS120 1.2 R134a 850 1330 1830 2390 2980 3750

    R404A 880 1320 1780 2290 2900

    CCNS140 1.4 R134a 950 1460 2040 2700 3440 4260

    R404A 1010 1730 2240 2830 3350

    CCN140 1.4 R134a 950 1460 2040 2700 3440 4260

    R404A 1010 1730 2240 2830 3350

    CCNS180 1.8 R134a 1440 2000 2770 3640 4560 5710

    R404A 1120 2090 2820 3650 4360

    CCN180 1.8 R134a 1440 2000 2770 3640 4560 5710

    R404A 1120 2090 2820 3650 4360

    CCN200 2.0 R134a 1720 2410 3190 4090 5100 6220

    R404A 1860 2500 3170 3950 4660

    CCN270 2.7 R134a 2120 3060 4140 5360 6740 8270

    R404A 2300 3250 4250 5220 6410

    CCN330 3.3 R134a 2960 3680 4820 6180 7610 8900

    R404A 2850 3890 4860 5840 6970

    CAPACITY (Watts) @ 32C Ambient

  • www.pattonnz.com

    The

    com

    pany

    rese

    rves

    the

    right

    to m

    ake

    spec

    ifica

    tion

    chan

    ges

    with

    out n

    otic

    e. 0

    9/07

    /14

    CCNS100 1.0 CS10K6E-PFJ 220-240/1/50 38.1 10.1 55.0 730 145 0.75 3.7 3/8 F.Sw. 3/4 F.Sw. 60 67

    CCNS120 1.2 CS12K6E-PFJ 220-240/1/50 44.4 10.9 55.0 730 145 0.75 3.7 3/8 F.Sw. 3/4 F.Sw. 60 67

    CCNS140 1.4 CS14K6E-PFJ 220-240/1/50 48.6 12.5 58.0 730 145 0.75 3.7 3/8 F.Sw. 3/4 F.Sw. 60 67

    CCN140 1.4 CS14K6E-TFD 380-420/3/50 48.6 4.7 28.0 736 145 0.75 3.7 3/8 F.Sw. 3/4 F.Sw. 60 67

    CCNS180 1.8 CS18K6E-PFJ 220-240/1/50 61.4 13.6 64.0 710 145 0.75 3.7 3/8 F.Sw. 3/4 F.Sw. 61 77

    CCN180 1.8 CS18K6E-TFD 380-420/3/50 61.4 4.7 33.0 710 145 0.75 3.7 3/8 F.Sw. 3/4 F.Sw. 61 77

    CCN200 2.0 CS20K6E-TFD 380-420/3/50 74.3 5.1 40.0 980 260 1.5 3.7 1/2 F.Sw. 3/4 F.Sw. 61 79

    CCN270 2.7 CS27K3E-TFD 380-420/3/50 92.4 8.5 41.0 1460 290 1.5 6.2 1/2 F.Sw. 7/8 F.Sw. 64 90

    CCN330 3.3 CS33K3E-TFD 380-420/3/50 106.2 9.9 45.0 1460 290 1.5 6.2 1/2 F.Sw. 7/8 F.Sw. 64 92

    MODEL

    COMPRESSOR CONDENSER RECEIVER CONNECTIONS (3)

    MODEL VOLTAGE

    Weight (kg)Airflow

    l/sec

    Fan Motor (1)

    Amps

    Capacity (kg) (2)

    Rec. Outlet

    Rotolock

    Comp. Suction

    RotolockWatts

    DISP.(cc)

    NOM.hp

    FLAAmps

    LRAAmps

    Noise Level (dbA)

    (4)

    1. Fan motors are suitable for 220-240/1/50

    2. R404A pump down capacity shown @ 80% full for 32C liquid temperature

    3. Max valve connection size shown. May reduce for different refrigerants & applications

    4. All noise level ratings are free field based at a distance of 3 metres from source and are given as a guide only

    5. *Capacity ratings are based on suction gas returning to compressor @ 20C, without liquid sub-cooling. Ratings may be increased by approximately 1% for every 1.1K of sub-cooling

    6. Standard condensers fitted. Ratings must not be extrapolated

    7. Check with Pattons nearest outlet for applications outside the specified range

    8. Pictured unit configuration subject to change and selected accessory options.

    NOTES:

    DIMENSIONS

    TECHNICAL DATA

    CCNS100CCNS120CCNS140CCN140

    CCNS180CCN180CCN200

    CCN270CCN330

    600

    570 MC 15 500 MC 750

    448

    3

    0

    15

    700

    15 670 MC

    40

    800

    458

    (56

    0 - C

    CN

    200)

    500 MC 15

    970 MC

    1000

    15

    470

    800

    500 MC 15

    52

    CCNS100CCNS120CCNS140CCN140

    CCNS180CCN180CCN200

    CCN270CCN330

    MC = MOUNTING BOLT CENTERS

    D

    E

    F

    C

    1 2 3 4

    B

    A

    321 5

    C

    D

    4 6 7 8

    A

    B

    PL01-ASM-CCN01

    CRAIG P.

    RAY K.

    CAMERON W.

    WEIGHT:

    A3

    SHEET 1 OF 1SCALE:

    DWG NO.

    TITLE:DATESIGNATURENAME

    Q.A

    MFG

    APPV'D

    DRAWN

    CUT SIZE:

    THE DRAWING AND INFORMATION CONTAINEDHEREIN ARE THE EXCLUSIVE PROPERTIES OF PATTON LIMITED. IT SHALL BE RETURNED UPONDEMAND AND SHALL NOT BE REPRODUCED INWHOLE OR IN PART, DISCLOSE TO ANYONE ELSEOR USED WITHOUT THE WRITTEN CONSENT OFPATTON LIMITED.

    REVISED BY REV ECN NO.

    - -

    CHK'D

    RAY K.

    DESCRIPTION DATE

    ECN-21-AUG-2013

    CCNS100, CCNS120, CCNS140, CCN140,CCNS180, CCN180, CCN200, CCN270 &CCN330 GA

    DD-MM-YY

    PROPRIETARY AND CONFIDENTIALNTS (mm)

    MC = Mounting Bolt Centers

    Accessories not shown

  • www.pattonnz.com

    CCK Medium / High

    CC

    K M

    ED

    /HIG

    H

    MODEL Nom. Refrigerant Evaporating Temp C hp -25 -20 -15 -10 -5 0 5 10

    CCKS175 1.75 R134a 1200 1590 2130 2810 3490 4200

    R404A 1250 1710 2180 2710 3310 3940

    CCKS200 2.0 R134a 1330 1830 2390 2980 3750 4510

    R404A 1320 1780 2290 2900 3380 4230

    CCKS225 2.25 R134a 1580 2190 2840 3700 4630 5700

    R404A 1820 2420 3050 3720 4380 5250

    CCK225 2.25 R134a 1580 2190 2840 3700 4630 5700

    R404A 1820 2420 3050 3720 4380 5250

    CCKS275 2.75 R134a 2120 2920 3890 4970 6340 7500

    R404A 2200 3060 3970 5010 6030 7060

    CCK275 2.75 R134a 2120 2920 3890 4970 6340 7500

    R404A 2200 3060 3970 5010 6030 7060

    CCK300 3.0 R134a 2600 3430 4380 5570 6760 7880

    R404A 2720 3490 4330 5460 6460 8150

    CCK400 4.0 R134a 3230 4380 5620 7200 8840 10410

    R404A 3470 4510 5710 7000 8370 10290

    CCK500 5.0 R134a 3980 5210 6700 8510 10130 11650

    R404A 4180 5460 6760 8260 9990 12030

    1.75 5 hp

    Air CooledCondensing Units

    n Reliable and efficient Copeland

    reciprocating hermetic compressors

    n Generous wide finned, low noise level

    condensers supplied with protective

    coil coating

    n Wide range of factory fitted

    accessories available

    n Specifically designed for

    Australasian conditions

    CAPACITY (Watts) @ 32C Ambient

  • www.pattonnz.com

    The

    com

    pany

    rese

    rves

    the

    right

    to m

    ake

    spec

    ifica

    tion

    chan

    ges

    with

    out n

    otic

    e. 0

    9/07

    /14

    CCKS175 1.75 CS10K6E-PFJ 220-240/1/50 38.1 10.1 55.0 730 145 0.75 3.7 3/8 F.Sw. 3/4 F.Sw. 60 67

    CCKS200 2.0 CS12K6E-PFJ 220-240/1/50 44.4 10.9 55.0 980 260 1.5 3.7 3/8 F.Sw. 3/4 F.Sw. 61 70

    CCKS225 2.25 CS14K6E-PFJ 220-240/1/50 48.6 12.5 58.0 980 260 1.5 3.7 3/8 F.Sw. 3/4 F.Sw. 61 70

    CCK225 2.25 CS14K6E-TFD 380-420/3/50 48.6 4.7 28.0 980 260 1.5 3.7 3/8 F.Sw. 3/4 F.Sw. 61 70

    CCKS275 2.75 CS18K6E-PFJ 220-240/1/50 61.4 13.6 64.0 1460 290 1.5 6.2 1/2 F.Sw. 3/4 F.Sw. 64 86

    CCK275 2.75 CS18K6E-TFD 380-420/3/50 61.4 4.7 33.0 1460 290 1.5 6.2 1/2 F.Sw. 3/4 F.Sw. 64 86

    CCK300 3.00 CS20K6E-TFD 380-420/3/50 74.3 5.1 40.0 1460 290 1.5 6.2 1/2 F.Sw. 3/4 F.Sw. 64 88

    CCK400 4.00 CS27K3E-TFD 380-420/3/50 92.4 8.5 41.0 1510 290 1.5 6.2 1/2 F.Sw. 7/8 F.Sw. 62 98

    CCK500 5.00 CS33K3E-TFD 380-420/3/50 106.2 9.9 45.0 1470 290 1.5 8.8 5/8 F.Sw. 7/8 F.Sw. 63 108

    MODEL

    COMPRESSOR CONDENSER RECEIVER CONNECTIONS (3)

    MODEL VOLTAGE

    Weight (kg)Airflow

    l/sec

    Fan Motor (1)

    Amps

    Capacity (kg) (2)

    Rec. Outlet

    Rotolock

    Comp. Suction

    RotolockWatts

    DISP.(cc)

    NOM.hp

    FLAAmps

    LRAAmps

    Noise Level (dbA) (4)

    1. Fan motors are suitable for 220-240/1/50

    2. R404A pump down capacity shown @ 80% full for 32C liquid temperature

    3. Max valve connection size shown. May reduce for different refrigerants & applications

    4. All noise level ratings are free field based at a distance of 3 metres from source and are given as a guide only

    5. *Capacity ratings are based on suction gas returning to compressor @ 20C, without liquid sub-cooling. Ratings may be increased by approximately 1% for every 1.1K of sub-cooling

    6. Standard condensers fitted. Ratings must not be extrapolated

    7. Check with Pattons nearest outlet for applications outside the specified range

    8. Pictured unit configuration subject to change and selected accessory options.

    NOTES:

    DIMENSIONS

    TECHNICAL DATA

    NTS (mm)

    MC = Mounting Bolt Centers

    Accessories not shown

    CCKS275CCK275CCK300

    CCK400

    CCK500

    CCKS175 CCKS200 CCKS225 CCK225

    600

    570 MC 15 500 MC 750

    448

    3

    0

    15

    700

    15 670 MC

    40

    800

    458

    (56

    0 - C

    CN

    200)

    500 MC 15

    970 MC

    1000

    15

    470

    800

    500 MC 15

    52

    CCNS100CCNS120CCNS140CCN140

    CCNS180CCN180CCN200

    CCN270CCN330

    MC = MOUNTING BOLT CENTERS

    D

    E

    F

    C

    1 2 3 4

    B

    A

    321 5

    C

    D