31
Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Remote Alarm Reporting and Site Monitoring Equipment Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite # 108, Fountain Hills, AZ 85268, U.S.A. Phone: +1 (480) 816-8672 Fax: +1 (480) 816-0115 E-mail: [email protected] Web Site: http://www.oriontelecom.com

Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite

Embed Size (px)

Citation preview

Page 1: Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite

Orion Telecom Networks Inc. 2005

Remote Alarm Reporting andRemote Alarm Reporting andSite Monitoring EquipmentSite Monitoring Equipment

Slide 1

Updated : January 1st, 2005

16810, Avenue of Fountains, Suite # 108,Fountain Hills, AZ 85268, U.S.A.

Phone: +1 (480) 816-8672Fax: +1 (480) 816-0115

E-mail: [email protected] Site: http://www.oriontelecom.com

Page 2: Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite

Orion Telecom Networks Inc. 2005

Remote Alarm Remote Alarm SuiteSuite

Remote Alarm Reporting, Site Monitoring and Management Remote Alarm Reporting, Site Monitoring and Management

Equipment SuiteEquipment Suite offer three types of solutionsoffer three types of solutions

Product OverviewProduct Overview

Remote Alarm Reporting - Solution # 1Remote Alarm Reporting - Solution # 1

Remote Site Monitoring - Solution # 2Remote Site Monitoring - Solution # 2

Line Testing - Solution # 3Line Testing - Solution # 3

Slide 2

Page 3: Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite

Orion Telecom Networks Inc. 2005

Used to configure, monitor, control and manage

remote sites from a central monitoring location over

• Dedicated serial data (RS232) links,

• Over the Internet (TCP/IP protocol).

Remote Alarm Reporting, Site Monitoring and Remote Alarm Reporting, Site Monitoring and

Management Equipment SuiteManagement Equipment Suite - An Overview- An Overview

Remote Alarm Remote Alarm SuiteSuite

Slide 3

Page 4: Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite

Orion Telecom Networks Inc. 2005

Remote Site Alarm Input TerminalRemote Site Alarm Input Terminal

• Access, manage and control Remote Site Alarms

• Alarms Reporting.

• Manage through PC using a Window based GUI

• Can be accessed, managed and controlled from a Central Site over :

a) Serial RS232 Data Link

b) The Internet (using TCP/IP Protocol)

Central Site Alarm Recording EquipmentCentral Site Alarm Recording Equipment

• Store and (continuously) log ALL Alarms that, may appear at the Remote

Sites during any given 7 days & 24 hour time period.

• Can configure the Remote Site equipment using a Windows based GUI

Remote Alarm Remote Alarm SuiteSuite

Slide 4

Page 5: Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite

Orion Telecom Networks Inc. 2005

Uses and ApplicationsUses and Applications

• SCADA applications power distribution lines, oil pipe lines,

gas pipelines and water pipe lines.

• Monitoring and Managing Remote (unmanned) Cellular Sites.

• Managing and Monitoring Remote Radio Relay (unmanned) Sites.

• Managing and Monitoring Remote DLC or RSU (unmanned)

telecom sites.

• Security and Surveillance.

Remote Alarm Remote Alarm SuiteSuite

Slide 5

Page 6: Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite

Orion Telecom Networks Inc. 2005

Remote Alarm Reporting, Site Monitoring and Management Remote Alarm Reporting, Site Monitoring and Management Equipment Suite offers the following alarms and functionsEquipment Suite offers the following alarms and functions

• Remote Site Alarms

• Equipment Alarm(s) Relay Open / Relay Close (User Configurable) Up to 32 Alarm Inputs per Site / Location.

• Intruder Alarm

• Fire Alarm

• Smoke Alarm

• Flooding Alarm.

• AC Mains Power Failure Alarm, etc.

Remote Alarm Remote Alarm SuiteSuite

Slide 6

Page 7: Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite

Orion Telecom Networks Inc. 2005

• Remote Site Monitoring Facility

To Monitor following parameters

• Remote Site Temperature

• AC Mains Voltage at the Remote Site

• DC Battery Voltage of the battery-bank of the power backup

equipment (12VDC and 48VDC).

• Remote Site Control Facility

Management of the power back-up battery banks

• Read voltage remotely

• Set threshold limit to shut-down / switch over to another

source - AC main or Solar

Remote Alarm Remote Alarm SuiteSuite

Slide 7

Page 8: Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite

Orion Telecom Networks Inc. 2005

• Temperature Monitoring and Management facility

• “Monitor and Read” temperature of each remote sites

• Site environmental management

Remote Alarm Remote Alarm SuiteSuite

• automatically "switch-on" or "switch-off" vent fans /

heaters / air conditioners at the high / low temperature

thresholds set by the User.

• Providing a power "Re-Set” to any equipment - remotely

• Initiate and provide a Power-Set (turn-off / turn-on) to any

equipment installed at the Remote Site from a Central

Monitoring location.

Slide 8

Page 9: Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite

Orion Telecom Networks Inc. 2005

• Remote line / cable pair testing - Telecom application

• Perform the line testing of the remote cable pairs

• Test the line for Open, Short, Leakage and the presence of "foreign" AC potential on the cable pairs.

• Ideal for Telco deployment at hard-to-reach unmanned Remote Sites

• Helps to isolate the faulty cable pair before making a service call

Remote Alarm Remote Alarm SuiteSuite

Slide 9

Page 10: Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite

Orion Telecom Networks Inc. 2005

Remote Site Terminal: Remote Site Terminal:

• Connect up to 32 Relay Inputs

• Powered by -48 VDC input (AC main optional)

• “Relay Open” or “Relay Close” condition to generate an “Alarm” - User Configurable

• Used to monitor, control and manage remote sites from a central monitoring location over

a) Dedicated Serial data (RS232) links

b) Over the Internet (TCP/IP protocol).

Solution # 1:Solution # 1:

Slide 10

Remote Alarm Remote Alarm SuiteSuite

Page 11: Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite

Orion Telecom Networks Inc. 2005

Central Site EquipmentCentral Site Equipment

• Report and recognize upto 32 Alarm Inputs at each Remote Site

• Store and (continuously) log ALL Alarms that, may appear

at the Remote Sites during any given 7 days & 24 hour

time period.

• Configure using a Window based GUI

• Display the status of all the Active Alarm on LCD display

• Can be connected upto 8 Remote Sites

Slide 11

Remote Alarm Remote Alarm SuiteSuite

Page 12: Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite

Orion Telecom Networks Inc. 2005

Dedicated serial data (RS-232) links

(Example: using dedicated serial data (RS-232) links )

1 to 32 Relays

1 to 32 Relays

1 to 32 Relays

1 to 32 Relays 1 to 32 Relays

1 to 32 Relays

1 to 32 Relays

1 to 32 Relays

VCL-Remote Device

VCL-Remote Device

VCL-Remote Device

VCL-Remote Device

VCL-Remote Device

VCL-Remote Device

VCL-Remote Device

VCL-Remote Device

Dedicated Serial (Asynchronous, RS 232)

Links

VCL-MonitoringSystem

Site 1

Site 2

Site 3

Site 4

Site 5

Site 6

Site 7

Site 8

Slide 12

Remote Alarm Remote Alarm SuiteSuite

Page 13: Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite

Orion Telecom Networks Inc. 2005

Central Office

VCL-MonitoringSystem

VCL-Remote Device

VCL-Remote Device

VCL-Remote Device

VCL-Remote Device

HUB HUB

HUB HUB

Remote Network(s)3 through 6

Ne

two

rke

d(T

CP

/IP

Pro

toco

l)N

etw

orke

d(T

CP

/IP P

roto

col)

INTERNETINTERNET

TCP/IP Protocol Networked (Internet) Links

10 BaseT Ethernet

Remote Network / Site 1

Remote Network / Site 2 Remote Network / Site 7

Remote Network / Site 8

(Example : using TCP/IP protocol networked (Internet) Links)

Networked(TCP/IP Protocol)

32 Relay Inputs 32 Relay Inputs

32 Relay Inputs 32 Relay Inputs

Slide 13

Remote Alarm Remote Alarm SuiteSuite

Page 14: Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite

Orion Telecom Networks Inc. 2005

VCL-Remote Device

Mixed network of dedicated serial (RS-232)Data links and network (TCP/IP) protocol links

Central Office

VCL-MonitoringSystem

Dedicated Serial

(Asynchronous, RS 232) Links

Remote Site 8

32 Relay Inputs

32 Relay Inputs32 Relay Inputs

32 Relay Inputs

Remote Site(s) 6 through 7Remote Network / Site 2

Remote Network / Site 1

VCL-Remote Device

VCL-Remote DeviceVCL-Remote

Device

HUB

HUB

INTERNETINTERNET

Remote Network(s)3 through 4

10 BaseT Ethernet

(Example: Using a "mixed" network of dedicated serial (RS-232) Data links and network (TCP/IP) protocol links)

Remote Site 5

Slide 14

Remote Alarm Remote Alarm SuiteSuite

Page 15: Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite

Orion Telecom Networks Inc. 2005

RJ-45 for connection withdedicated serial data (RS-232)links or networked TCP-IP links

DB-9 for connectionwith PC

Central site - Alarm Monitoring Equipment (Back View)

- 48 V5V

“Scroll” LCD Display

ACKRemoteSite #

AlarmSite #

System # (Remote #)Alarm #

Text of Alarm(Configured by the user)

Central site - Alarm Monitoring Equipment (Front View)

Alarm AcknowledgeSwitch

Slide 15

Remote Alarm Remote Alarm SuiteSuite

Page 16: Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite

Orion Telecom Networks Inc. 2005

Central Site Alarm Recording Equipment : Specifications Central Site Alarm Recording Equipment : Specifications

Specifications of RS 232 @ 9.6Kbps, Asynchronous Data Interface Port for

Serial (Point to Point) Connection : to connect upto 8 remote sites to the

central monitoring site on point to point serial data links.

Number of Remote Site (Remote Terminals)That can be Connected to central siteMonitoring Equipment 8 (Remote Terminals)

Type RS 232Tx, Rx, Gnd

Mode Asynchronous

Baud Rate 9.6 kbps - Fixed

Data Size 8bits

Parity None

Flow Control None ( Xon / Xoff )

Stop Bit 1

Slide 16

Remote Alarm Remote Alarm SuiteSuite

Page 17: Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite

Orion Telecom Networks Inc. 2005

Ethernet Specifications @ 10 BaseT Data Interface Port for Networked

(IP/Internet) Connection : to connect upto 8 remote sites to the central

monitoring site over networked (IP/Internet) links.

Number of Remote Site (Remote Terminals)That can be Connected to central siteMonitoring Equipment 8 (Remote Terminals)

Conformity IEEE 802.3.

Type 4 Wire,Twisted Pair Cabling. (Categories 3, 4 or 5).

Distance limit 100 metres (Approx. 328 feet)per Segment.

Bit Rate 10 Mbps.

Power:-48VDC (AC Input Optional)

Dimensions:2U High19-inch Shelf (19-inch rack mounting).

Slide 17

Remote Alarm Remote Alarm SuiteSuite

Page 18: Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite

Orion Telecom Networks Inc. 2005

Specifications of RS 232 @ 9.6Kbps, Asynchronous Data Interface Port for Serial (Point to Point) Connection : to connect upto 8 remote sites to the central monitoring site on point to point serial data links.

Number of Relay Inputs (User Configurable - Relay Open Relay Close Alarm Inputs)Per Remote Site Terminal 32

Connection between Remote Site Terminaland Central Site Terminal

Serial Data Interfaces 1

Type RS 232Tx, Rx, Gnd

Mode Asynchronous

Baud Rate 9.6 kbps - Fixed

Data Size 8bits

Parity None

Flow Control None ( Xon / Xoff )

Stop Bit 1.

Slide 18

Remote Alarm Remote Alarm SuiteSuite

Page 19: Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite

Orion Telecom Networks Inc. 2005

Ethernet Specifications @ 10 BaseT Data Interface Port for Networked (IP / Internet) Connection : to connect upto 8 remote sites to the central monitoring site over networked (IP/Internet) links.

Connection between remote site terminaland central site terminal

Ethernet Interfaces 1

Conformity IEEE 802.3.

Type 4 Wire, Twisted Pair Cabling. (Categories 3, 4 or 5).

Distance limit 100 metres (Approx 328 feet) per Segment.

Bit Rate 10Mbps

Power:-48VDC (AC Input Optional)

Dimensions:1U High19-inch Shelf (19-inch rack mounting).

Slide 19

Remote Alarm Remote Alarm SuiteSuite

Page 20: Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite

Orion Telecom Networks Inc. 2005

Remote site - Alarm Input Terminal

32 Relay Inputs ("Relay Open", or

"Relay Close" condition to generate an "Alarm" -User Configurable).

DB-9 for connection withdedicated serial data (RS-232)

links

RJ-45 for connectionwith ethernet

Slide 20

Remote Alarm Remote Alarm SuiteSuite

Page 21: Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite

Orion Telecom Networks Inc. 2005

Solution # 2Solution # 2

• Remote Site Management & Monitoring can be connected to Central Site through

a) Dedicated Serial (RS232) data link

b) Internet TCP/IP Protocol

• Any number of Remote Site Monitoring equipment may be

installed and managed from Central Site.

• All Remote Site Monitoring, Management and Control function are accomplished through a PC using a Window based GUI.

Remote Site Monitoring EquipmentRemote Site Monitoring Equipment

Slide 21

Remote Alarm Remote Alarm SuiteSuite

Page 22: Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite

Orion Telecom Networks Inc. 2005

Provide the following Alarms:

• Intruder Alarm

• Fire Alarm

• Smoke Alarm

• Flooding Alarm.

• Equipment Alarm(s) Relay Open / Relay Close (User Configurable) Upto 5 Alarm Inputs per Site / Location.

Control and Manage the following functionsControl and Manage the following functions

• AC Mains Power Failure Alarm.

• And to select the “switch” to the selected back-up power source.

• “Read" and "Control" Remote Site Temperature

• Temperature monitoring and management facility

Slide 22

Remote Alarm Remote Alarm SuiteSuite

Page 23: Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite

Orion Telecom Networks Inc. 2005

• "Read" AC Mains Voltage at the Remote Site.

• “Read" DC Battery Voltage of the battery-bank of the power back-up equipment (12VDC and 48VDC) and "Manage" "battery-banks.

• Remotely read the voltage of power and back-up battery

• Set the threshold limit to shut down or to switch over to

another battery line “remotely”

• Useful in case where there is two power back-up units for

added protection

• To initiate a Power "Re-Set" of the connected Equipment.

• To provide a power reset to any equipment - remotely

Slide 23

Remote Alarm Remote Alarm SuiteSuite

Page 24: Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite

Orion Telecom Networks Inc. 2005

Dedicated Serial (Asynchronous, RS 232)

Links

Central Office

VCL-Remote Device

1 to 32 Relays

(Example: using dedicated serial data (RS-232) links )

Dedicated serial data (RS-232) links

Site 8

Slide 24

Remote Alarm Remote Alarm SuiteSuite

Page 25: Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite

Orion Telecom Networks Inc. 2005

VCL-Remote Device

32 Relay Inputs32 Relay Inputs

32 Relay Inputs 32 Relay Inputs

VCL-Remote Device

VCL-Remote Device

VCL-Remote Device

HUB

HUB

HUB

HUB

Ne

two

rke

d(T

CP

/IP

Pro

toco

l)N

etw

orke

d(T

CP

/IP P

roto

col)

INTERNETINTERNET

Remote Network(s)3 through 6

10 BaseT Ethernet

TCP/IP protocol networked (Internet) LinksCentral Office

Remote Network / Site 8

Remote Network / Site 7

Remote Network / Site 1

Remote Network / Site 2

(Example : using TCP/IP protocol networked (Internet) Links)

Slide 25

Remote Alarm Remote Alarm SuiteSuite

Page 26: Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite

Orion Telecom Networks Inc. 2005

VCL-Remote Device

HUB

10 BaseT Ethernet

VCL-Remote Device

VCL-Remote Device

HUB

INTERNETINTERNET

Remote Network(s)2 through 7

COM 2COM 1Dedicated Serial

(Asynchronous, RS 232)Links

Central Office

32 Relay Inputs

32 Relay Inputs

32 Relay Inputs

Remote Site 8Remote Network / Site 1

Remote Network / Site 8

Mixed network of dedicated serial (RS-232) Data links and network (TCP/IP) protocol links

(Example: Using a "mixed" network of dedicated serial (RS-232) Data links and network (TCP/IP) protocol links)

Slide 26

Remote Alarm Remote Alarm SuiteSuite

Page 27: Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite

Orion Telecom Networks Inc. 2005

Specifications of RS 232 @ 9.6Kbps, Asynchronous Data Interface Port for Serial (Point to Point) Connection : to connect upto 8 remote sites to the central monitoring site on point to point serial data links.

Number of relay inputs (user configurable - relay open relay close alarm inputs)Per Remote Site Terminal 32

Connection between Remote Site Terminaland Central Site Terminal

Serial Data Interfaces 1

Type RS 232Tx, Rx, Gnd

Mode Asynchronous

Baud Rate 9.6 kbps - Fixed

Data Size 8bits

Parity None

Flow Control None ( Xon / Xoff )

Stop Bit 1

Slide 27

Remote Alarm Remote Alarm SuiteSuite

Page 28: Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite

Orion Telecom Networks Inc. 2005

Ethernet Specifications @ 10 BaseT Data Interface Port for Networked (IP/Internet) Connection : to connect upto 8 remote sites to the central monitoring site over networked (IP/Internet) links.

Connection between remote site terminaland central site terminal

Ethernet Interfaces 1.

Conformity IEEE 802.3.

Type 4 Wire, Twisted Pair Cabling. (Categories 3, 4 or 5).

Distance limit 100 metres (Approx 328 feet) per Segment.

Bit Rate 10 Mbps.

Slide 28

Remote Alarm Remote Alarm SuiteSuite

Page 29: Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite

Orion Telecom Networks Inc. 2005

Solution # 3Solution # 3

• Remote line / cable pair testing - Telecom application

• Perform the line testing of the remote cable pairs

• Test the line for Open, Short, Leakage and the presence of "foreign" AC potential on the cable pairs.

• Ideal for Telco deployment at hard-to-reach unmanned Remote Sites

• Helps to isolate the faulty cable pair before making a service call

Slide 29

Remote Alarm Remote Alarm SuiteSuite

Page 30: Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite

Orion Telecom Networks Inc. 2005

Orion’s Orion’s ProductsProducts

E1, Voice & Data Drop-Insert Multiplexer

PRI ISDN (Q.931) Multiplexers

E1 Intelligent Channel Banks

E1 / T1 DCME (Digital Circuit Multiplication Equipment) - Voice Compression Equipment

Thin Route DCME

E1 / T1 Echo Cancellers

E1 / T1 Digital Cross Connect

T1 / E1 Converters

E3, 34Mbps Multiplexer

34Mbps Optical Line Transmission Equipment (OLTE)

STM 1 / STM 4 - SDH Equipment

Remote Asset Management Systems

Slide 30

Remote Alarm Remote Alarm SuiteSuite

Page 31: Orion Telecom Networks Inc. 2005 Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, 2005 16810, Avenue of Fountains, Suite

Orion Telecom Networks Inc. 2005

Thank you for your attentionThank you for your attention

For more details visit us at our Web Site at

http://www.oriontelecom.com

16810, Avenue of Fountains, Suite # 108,Fountain Hills, AZ 85268, U.S.A.

Phone: +1 (480) 816-8672 Fax: +1 (480) 816-0115E-mail: [email protected]

Slide 31

Remote Alarm Remote Alarm SuiteSuite