1 Observations in Shear Wall Strength in Tall Buildings Presented by StructurePoint at ACI Spring 2012 Convention in Dallas, Texas

Observations in Shear Wall Strength in Tall Buildings · ) OK u4 (P u3, M u3) OK (P, M u4) NG Notice: Absolute value of moments same on both sides Larger axial force favorable on

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Observations in Shear Wall Strength in Tall Buildings · ) OK u4 (P u3, M u3) OK (P, M u4) NG Notice: Absolute value of moments same on both sides Larger axial force favorable on

1

Observations in Shear Wall Strength in Tall Buildings

Presented by StructurePoint at ACI Spring 2012 Convention

in Dallas, Texas

Page 2: Observations in Shear Wall Strength in Tall Buildings · ) OK u4 (P u3, M u3) OK (P, M u4) NG Notice: Absolute value of moments same on both sides Larger axial force favorable on

2

Metropolitan Tower, New York City

68-story, 716 ft (218m) skyscraper

Reinforced Concrete Design of Tall Buildings by Bungale

S. Taranath

Page 3: Observations in Shear Wall Strength in Tall Buildings · ) OK u4 (P u3, M u3) OK (P, M u4) NG Notice: Absolute value of moments same on both sides Larger axial force favorable on

3

Page 4: Observations in Shear Wall Strength in Tall Buildings · ) OK u4 (P u3, M u3) OK (P, M u4) NG Notice: Absolute value of moments same on both sides Larger axial force favorable on

4

Page 5: Observations in Shear Wall Strength in Tall Buildings · ) OK u4 (P u3, M u3) OK (P, M u4) NG Notice: Absolute value of moments same on both sides Larger axial force favorable on

5

Jin Mao Tower, Shanghai, China

88-story, 1381 ft (421m)

Page 6: Observations in Shear Wall Strength in Tall Buildings · ) OK u4 (P u3, M u3) OK (P, M u4) NG Notice: Absolute value of moments same on both sides Larger axial force favorable on

6

Page 7: Observations in Shear Wall Strength in Tall Buildings · ) OK u4 (P u3, M u3) OK (P, M u4) NG Notice: Absolute value of moments same on both sides Larger axial force favorable on

7

Page 8: Observations in Shear Wall Strength in Tall Buildings · ) OK u4 (P u3, M u3) OK (P, M u4) NG Notice: Absolute value of moments same on both sides Larger axial force favorable on

8

Motivation

Sharing insight from detailed analysis and implementation of code provisions

Sharing insight from members of ACI committees

Sharing insight from wide base of spColumn users

Raising awareness of irregularities and their impact on design

Conclusions apply to all sections, but especially those of irregular shape and loaded with large number of load cases and combinations, e.g. Shear Walls

Page 9: Observations in Shear Wall Strength in Tall Buildings · ) OK u4 (P u3, M u3) OK (P, M u4) NG Notice: Absolute value of moments same on both sides Larger axial force favorable on

9

Outline

Observations

P-M Diagram Irregularities

Symmetry/Asymmetry

Strength Reduction Factor

Uniaxial/Biaxial Bending

Moment Magnification Irregularities

Conclusions

Page 10: Observations in Shear Wall Strength in Tall Buildings · ) OK u4 (P u3, M u3) OK (P, M u4) NG Notice: Absolute value of moments same on both sides Larger axial force favorable on

10

P-M Diagram

Design

(Pu1

, Mu1

) NG

(Pu2

, Mu2

) OK

(Pu3

, Mu3

) NG

Notice Pu1 < Pu2 < Pu3

with Mu

=const

One Quadrant OK if

Pu

0 and Mu

0

Section shape symmetrical

Reinforcement symmetrical

z

x

y

PM

Page 11: Observations in Shear Wall Strength in Tall Buildings · ) OK u4 (P u3, M u3) OK (P, M u4) NG Notice: Absolute value of moments same on both sides Larger axial force favorable on

11

P-M Diagram –

Pos./Neg. Load Signs

All four quadrants are needed if loads change sign

If section shape and reinforcement are symmetrical then M-

side is a mirror of M+ sideP (kip)

Mx (k-ft)

700

-200

180-18 0

(Pmax)(Pmax)

(Pmin)(Pmin)

1

2

3

4

5

6

7

8

9

10

Page 12: Observations in Shear Wall Strength in Tall Buildings · ) OK u4 (P u3, M u3) OK (P, M u4) NG Notice: Absolute value of moments same on both sides Larger axial force favorable on

12

P-M Diagram –

Asymmetric Section

Each quadrant different

(Pu1

, Mu1

) NG

(Pu2

, Mu2

) OK

(Pu3

, Mu3

) OK

(Pu4

, Mu4

) NG

Notice:

Absolute value of moments same on both sides

Larger axial force favorable on M+ side but unfavorable on M-

side

P (kip)

Mx (k-ft)

40000

-10000

60000-400 00

(Pmax)(Pmax)

(Pmin)(Pmin)

12

34

x

Mx>0

y

Compressionx

Mx<0Compression

Page 13: Observations in Shear Wall Strength in Tall Buildings · ) OK u4 (P u3, M u3) OK (P, M u4) NG Notice: Absolute value of moments same on both sides Larger axial force favorable on

13

P-M Diagram –

Asymmetric Steel

Skewed Diagram

Plastic Centroid ≠

Geometrical Centroid

(Concrete Centroid ≠

Steel Centroid)

(Pu1

, Mu1

) NG, (Pu2

, Mu2

) OK, (Pu3

, Mu3

) NG

|Mu1

| < |Mu2

| < |Mu3

| with Pu

= constP ( kN )

Mx ( kNm)

4500

-1500

450-45 0

(Pmax)(Pmax)

(Pmin)(Pmin)123

Page 14: Observations in Shear Wall Strength in Tall Buildings · ) OK u4 (P u3, M u3) OK (P, M u4) NG Notice: Absolute value of moments same on both sides Larger axial force favorable on

14

P-M Diagram –

Factor

Strength reduction factor = (t

)

t

n

n

(c ) Pusually

( P )sometimes

Compression controlled

fy

Es

0.75 or 0.70.65

Spiral*

Other

0.005

Transition zone Tension Controlled

0.9

c

1 c

Page 15: Observations in Shear Wall Strength in Tall Buildings · ) OK u4 (P u3, M u3) OK (P, M u4) NG Notice: Absolute value of moments same on both sides Larger axial force favorable on

15

P-M Diagram –

Factor

Usually

Sometimes

n(c ) ( P ) n(c ) ( P )

Sections with a narrow portion along height, e.g.: I, L, T, U, C-

shaped or irregular sections

Page 16: Observations in Shear Wall Strength in Tall Buildings · ) OK u4 (P u3, M u3) OK (P, M u4) NG Notice: Absolute value of moments same on both sides Larger axial force favorable on

16

P-M Diagram –

Factor

(Pu1

, Mu1

) OK, (Pu2

, Mu2

) NG, (Pu3

, Mu3

) OK Mu1

< Mu2

< Mu3

with Pu

= const

Page 17: Observations in Shear Wall Strength in Tall Buildings · ) OK u4 (P u3, M u3) OK (P, M u4) NG Notice: Absolute value of moments same on both sides Larger axial force favorable on

17

P-M Diagram –

Factor

(Pu1

, Mu1

) OK, (Pu2

, Mu2

) NG, (Pu3

, Mu3

) OK |Mu1

| < |Mu2

| < |Mu3

| with Pu

= const

Page 18: Observations in Shear Wall Strength in Tall Buildings · ) OK u4 (P u3, M u3) OK (P, M u4) NG Notice: Absolute value of moments same on both sides Larger axial force favorable on

18

P-M Diagram –

Factor

(Pu1

, Mu1

) OK

(Pu2

, Mu2

) NG (Pu3

, Mu3

) OK Pu1

< Pu2

< Pu3

with Mu

= const

P (k ip)

Mx (k -ft)

60000

-10000

70000-70000

fs=0.5fy

fs=0

fs=0.5fy

fs=0

(Pmax)(Pmax)

(Pmin)(Pmin)

fs=0.5fy

fs=0

fs=0.5fy

fs=0

123

fs=0.5fy

fs 0

123

t

nn

(c )M or( M ) or

Page 19: Observations in Shear Wall Strength in Tall Buildings · ) OK u4 (P u3, M u3) OK (P, M u4) NG Notice: Absolute value of moments same on both sides Larger axial force favorable on

19

Uniaxial/Biaxial –

Symmetric Case

3D failure surface with tips directly on the P axis

Uniaxial X = Biaxial P-Mx

with My = 0

Uniaxial Y = Biaxial P-My

with Mx

= 0

Page 20: Observations in Shear Wall Strength in Tall Buildings · ) OK u4 (P u3, M u3) OK (P, M u4) NG Notice: Absolute value of moments same on both sides Larger axial force favorable on

20

Uniaxial/Biaxial –

Asymmetric case

Tips of 3D failure surface may be off the P axis

Uniaxial X means N.A. parallel to X axis but this produces Mx

0 and My

0

Uniaxial X may be different than Biaxial P-Mx

with My

= 0

c

1 c

Page 21: Observations in Shear Wall Strength in Tall Buildings · ) OK u4 (P u3, M u3) OK (P, M u4) NG Notice: Absolute value of moments same on both sides Larger axial force favorable on

21

Uniaxial/Biaxial –

Asymmetric Case

Page 22: Observations in Shear Wall Strength in Tall Buildings · ) OK u4 (P u3, M u3) OK (P, M u4) NG Notice: Absolute value of moments same on both sides Larger axial force favorable on

22

Moment Magnification –

Sway Frames

Magnification at column ends (Sway frames)

M2

= M2ns

+ s

M2s

If sign(M2ns

) = -sign(M2s

) then the magnified moment, M2

, is smaller than first order moment (M2ns

+M2s

) or it can even change sign, e.g.:

M2ns

= 16 k-ft, M2s

= -10.0 k-ft,

= 1.2

M2

= 16 + 1.2 (-10.0) = 4.0 k-ft (M2ns

+M2s

) = 6.0 k-ft

M2ns

= 16 k-ft, M2s

= -14.4 k-ft,

= 1.2

M2

= 16 + 1.2 (-14.4) = -1.28 k-ft

(M2ns

+M2s

) = 1.6 k-ft

First-order moment may govern the design rather than second order-moment

Page 23: Observations in Shear Wall Strength in Tall Buildings · ) OK u4 (P u3, M u3) OK (P, M u4) NG Notice: Absolute value of moments same on both sides Larger axial force favorable on

23

Moment Magnification –

Sway Frames

Since ACI 318-08 moments in compression members in sway frames are magnified both at ends and along length

Prior to ACI 318-08 magnification along length applied only if

u

u'c g

35r P

f A

l

Page 24: Observations in Shear Wall Strength in Tall Buildings · ) OK u4 (P u3, M u3) OK (P, M u4) NG Notice: Absolute value of moments same on both sides Larger axial force favorable on

24

Moment Magnification –

M1

M1

may govern the design rather than M2

even though |M2

| > |M1

| and ACI 318, 10.10.6 provision stipulates that compression members shall be designed for Mc

= M2

. Consider:

Double curvature bending (M1

/M2

< 0)

Asymmetric Section

M2

OK but M1 NG

M

P

M2M1 M2M1

Page 25: Observations in Shear Wall Strength in Tall Buildings · ) OK u4 (P u3, M u3) OK (P, M u4) NG Notice: Absolute value of moments same on both sides Larger axial force favorable on

25

Moment Magnification –

M2nd/M1st

ACI 318-11, 10.10.2.1 limits ratio of second-order moment to first-order moments

M2nd/M1st < 1.4

What if ratio is negative, e.g.:

M1st

= Mns

+ Ms

= 10.0 + (-9.0) = 1.0 k-ft

M2nd = (Mns

+ s

Ms

) = 1.05 (10.0+1.3(-9.0)) = -1.78 k-ft

M2nd/M1st

= -1.78 OK or NG ?

Check |M2nd/M1st|= 1.78 > 1.4 NG

Page 26: Observations in Shear Wall Strength in Tall Buildings · ) OK u4 (P u3, M u3) OK (P, M u4) NG Notice: Absolute value of moments same on both sides Larger axial force favorable on

26

Moment Magnification –

M2nd/M1st

What if M1st

is very small, i.e. M1st < Mmin

, e.g.:

M1st

= M2

= 0.1 k-ft (Nonsway frame)

Mmin

= Pu

(0.6 +0.03h) = 5 k-ft

M2nd = Mc

= Mmin

= 1.1*5 = 5.5 k-ft

M2nd/M1st

= 5.5/0.1 = 55 OK or NG ?

Check M2nd/Mmin

= 1.1 OK

Page 27: Observations in Shear Wall Strength in Tall Buildings · ) OK u4 (P u3, M u3) OK (P, M u4) NG Notice: Absolute value of moments same on both sides Larger axial force favorable on

27

Conclusions

Summary

Irregular shapes of sections and reinforcement patterns lead to irregular and distorted interaction diagrams

Large number of load cases and load combinations lead to large number of load points potentially covering entire (P, Mx

, My

) space

Intuition may overlook unusual conditions in tall structures

Page 28: Observations in Shear Wall Strength in Tall Buildings · ) OK u4 (P u3, M u3) OK (P, M u4) NG Notice: Absolute value of moments same on both sides Larger axial force favorable on

28

Conclusions

Recommendations

Do not eliminate load cases and combinations based on intuition

Run biaxial rather than uniaxial analysis for asymmetric sections

Run both 1st order and 2nd

order analysis

Apply engineering judgment rather than following general code provisions literally

Use reliable software and verify its results