1Rev 4d
Nimble Technical Sales Professional Accreditation
Nimble Storage Array Introduction, Installation, and Maintenance
Rev 4d
Checking Your Enrollment
1. Login to http://university.nimblestorage.com/2. Click My Account3. Verify todays course is listed and then click Go
4. Ensure your status states Enrolled with an X next to it (Dont click the X)
5. If your screen looks different, ask your instructor for instructions2
Classroom NetworkSSID
Password
2Rev 4d
Introductions
Name Company Position Data storage background What do you hope to get out of the course?
Rev 4d
In this course the following subjects will be discussed:
Section 1: CS-Series Array Introduction
Section 2: Scale-to-Fit Section 3: CASL Architecture Section 4: Networking and Cabling Section 5: Initial Installation Section 6: Array Administration Section 7: Working with Volumes
Section 8: Connecting to Hosts Section 9: Snapshots Section 10: Replication Section 11: Data Protection and DR Section 12: Maintenance and
Troubleshooting Section 13: Support
Topics
3Rev 4d
Section 1: CS-Series Array Introduction
Rev 4d
Raw versus Usable versus Effective Capacity
Raw Capacity Usable
Capacity
EffectiveCapacity
Subtract capacity
forRAID-6 parity,
spares &system
reserves
Add storagecapacity due
to inline compression (typical 30%
to 75%)
Raw: 24 TB Usable: 17 TB Effective: 33 TB(assuming 50% compression)
4Rev 4d
Nimble Storage CS210 At a Glance
7
Model CPU DDR3 Memory
Ethernet Ports
Cache SSD
Data HDD
Effective Capacity0 2x
CS210 1 12GB 4x 1GbE 2x 80GBor
160GB
8x 1TBor
8TB RAW
4TB 9TB
No 10 GbEoption
Capacity Expansion Add up to 1 additional shelf
Scaling Performance Supports scaling cache (X2 and X4)
Rev 4d
Nimble Storage CS220 at a Glance
8 2012 Nimble Storage, Inc.
Model CPU DDR3 Memory
Ethernet Ports
Cache SSD Cache Total
Data HDD
Eff. Capacity0 2x
CS220
1 12GB
6x1GbE
4x80GB 320GB
12x1TBor
12 TBRAW
8TB 16TBCS220G 2x1GbE2x10GbE
Capacity Expansion Add up to 3 additional shelf
Scaling Performance Scale Compute and Cache (x2, x4, or x8)
5Rev 4d
Model CPU DDR3 Memory
Ethernet Ports
Cache SSD Cache Total
Data HDD
Eff. Capacity0 2x
CS240
1 12GB
6x1GbE
4x160GB 640GB
12x2TBor
24 TBRAW
17TB 33TBCS240G 2x1GbE2x10GbE
Nimble Storage CS240 at a Glance
9 2012 Nimble Storage, Inc.
Capacity Expansion Add up to 3 additional shelf
Scaling Performance Scale Compute and Cache (x2, x4)
Rev 4d
Nimble Storage CS260 at a Glance
10 2012 Nimble Storage, Inc.
Model CPU DDR3 Memory
Ethernet Ports
Cache SSD Cache Total
Data HDD
Eff. Capacity0 2x
CS260
1 12GB
6x1GbE
4x300GB 1.2TB
12x3TBor
36 TBRAW
25TB 50TBCS260G
2x1GbE2x10GbE
Capacity Expansion Add up to 3 additional shelf
Scaling Performance Scale Compute and Cache (x2, x4)
6Rev 4d
Nimble Storage CS420 at a Glance
11 2012 Nimble Storage, Inc.
Model CPU DDR3 Memory
Ethernet Ports
Cache SSD Cache Total
Data HDD
Eff. Capacity0 2x
CS420(1)
2 24GB6x1GbE
4x160GB or 4x300GB
640GBto
1.2TB
12TB 8TB 16TBCS440 24TB 17TB 33TBCS460 2x1GbE
2x10GbE 36TB 25TB 50TB
Capacity Expansion Add up to 3 additional shelf
Scaling Performance Cache (x2, x4, or x8*)*only the CS420 supports the x8 option
(1) Sold only with X2, X4, or x8 options
Rev 4d
Hardware Tour - Front
3U
7Rev 4d
Hardware Tour Controller Unit Front
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
CS-Series 210
HDD HDDblank blank
LEDsLEDs
PWRSSD options*
*default configuration uses two SSD slots and two blanks
Rev 4d
Hardware Tour Controller Unit Front
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
CS220 and higher
HDD HDDSSD
8Rev 4d
Disks
Disks: 16 hot swappable drive bays populated with:
8 or 12 SATA (with SAS interposers) or SAS disks 2 or 4 solid-state drives (SSD)
When replacing a drive, ensure you replace drives with the appropriate type!
Rev 4d
Nimble ES-Series External Storage Shelf
Connect one per CS210 or up to three to the CS220 and higher model numbers
Scale storage capacity non-disruptively Uses 4 Lane 6Gb SAS connectivity from controller to shelf
Support redundant data paths from controller to shelves
Each shelf is its own RAID Group Spares assigned for each shelf
16
ES1-H25 ES1-H45 ES1-H65
Individual disk drive size 1TB Disks 2TB Disks 3TB Disks
Raw Capacity 15 TB 30 TB 45 TB
Effective Capacity(w/ 0x-2x compression) 11 22 TB 23 45 TB 34 68 TB
Flash 160 GB 300 GB 600 GB
Connectivity 2x 6Gb SAS / IO module
IO Modules Dual hot-swappable SAS controllers
9Rev 4d
Hardware Tour Front
HDD
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Expansion Shelf
HDDSSD
Rev 4d
Hardware Tour - Back
1 2
3 456
8
7
10
Rev 4d
Hardware Components
Power supplies 2X 100-240V, 50-60Hz, 4-10 Amp Power requirement 500 watts
Rev 4d
Controllers
Work in Active / Standby configuration Hot swappable Supports non-disruptive Nimble OS upgrades Review all messages regarding controller failure to identify the proper
controller Any of the following events can indicate that a controller has failed:
LEDs indicate that no activity currently occurs on the controller that was active NVRAM LEDs are dark Heartbeat LED is dark Event appears in the Events list Receipt of an alert email from the array
20 2012 Nimble Storage, Inc.
11
Rev 4d
Controllers Nimble OS Upgrade
One-click, zero-downtime Nimble OS upgrades
Before you begin: Check your current version Obtain the most recent version Check system health
Rev 4d
Nimble OS Upgrade Process
Active Standby
Firmware
ActiveStandbyFailover
1. Load new firmware to standby2. Reboot standby to run new rev.3. Load new firmware to other controller4. Reboot active to activate new rev.
causes failover and the standby becomes active
Firmware
12
Rev 4d
Section 2: Scale to Fit
Rev 4d
Nimble Scaling for Mainstream Applications
Mainstream Applications
PER
FOR
MAN
CE
CAPACITY
+ NODES+ NODES+ NODES
13
Rev 4d
Nimble Scaling for Mainstream Applications
Mainstream Applications
PER
FOR
MAN
CE
CAPACITY
`
Real-time Analytics
VDI
SQL Server
Exchange
Backup, DR
Archival, Cheap and Deep
SharePoint
Oracle
Rev 4d
Scale Capacity by Adding Disk Shelves
Add capacity non-disruptively by adding external disk shelves
A disk shelf contains high capacity HDDs and a SSD
Add multiple disk shelves per Nimble Storage array
Add up to three shelves Only one shelf for the CS-210
Mix and match different capacity shelves
Sufficientperformance, but need more capacity
P
C
Add
Once Expansion Shelves have been added they cannot be removed.
14
Rev 4d
Scale Capacity Cabling
4 Lane 6Gb cable 1 to 3 meters in length
Do not connect SAS cables to an expansion shelf
until after the array has been
upgraded to 1.4
Rev 4d
Adding a Shelf
1. Check to see if you have proper Nimble OS version2. Cable new expansion shelf and power on3. The new shelf is discovered by the control head
Newly discovered shelves will be shown as Available in the GUI/CLI4. Using the GUI or CLI, activate the new shelf
28 2012 Nimble Storage. Proprietary and confidential. Do not distribute.
15
Rev 4d
Adding a Shelf
29 2012 Nimble Storage. Proprietary and confidential. Do not distribute.
Discovering
Available Activate In Use
Is there data on
the disks?
Foreign
Faulty
No
Yes Force Activate
Rev 4d
Scale Capacity Storage Pool
Storage pool grows when an expansion shelf is activated. Segment Layer is updated with new ending block data
The segment layer provides a map between the Nimble file system addresses and disk locations
The map is dynamically created for each incoming write request Essentially the segment layer works as a traffic cop by directing writes to the
proper disks
30 2012 Nimble Storage. Proprietary and confidential. Do not distribute.
16
Rev 4d
Expanding Existing System
31 2012 Nimble Storage. Proprietary and confidential. Do not distribute.
50% Capacity
Fill Expansion Shelf until capacity utilization
matches the control head
Then balance capacity between them
Controller ShelfExpansion Shelf
21
50% Capacity
Rev 4d
Managing Internal Storage and Expansion Shelves
X X
NO
17
Rev 4d
Power On/Off Order
On Power expansion shelves
first, then the controller shelves
33 2012 Nimble Storage. Proprietary and confidential. Do not distribute.
Off Power off the controller
shelf and then the expansion shelves