3-90-08422JR11_03/14 SAVE THESE INSTRUCTIONS. Installation & Operating Manual SAFETY NOTICE PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW ROOM HEATER. FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH. FOR USE IN THE U.S. AND CANADA. SUITABLE FOR INSTALLATION IN MOBILE HOMES. IF THIS HARMAN STOVE IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. FOR YOUR SAFETY, FOLLOW INSTALLATION DIRECTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA. CONTACT YOUR LOCAL AUTHORITY (SUCH AS MUNICIPAL BUILDING DEPARTMENT, FIRE DEPARTMENT, FIRE PREVENTION BUREAU, ETC.) TO DETERMINE THE NEED FOR A PERMIT. CETTE GUIDE D'UTILISATION EST DISPONIBLE EN FRANCAIS. CHEZ VOTRE CONCESSIONNAIRE DE HARMAN HOME HEATING. Model(s): P38+ Freestanding Pellet Stove NOTICE: SAVE THESE INSTRUCTIONS Hot glass will cause burns. Do not touch glass until it is cooled NEVER allow children to touch glass Keep children away CAREFULLY SUPERVISE children in same room as stove. Alert children and adults to hazards of high temperatures. High temperatures may ignite clothing or other flammable materials. Keep clothing, furniture, draperies and other flammable materials away. HOT SURFACES! Glass and other surfaces are hot during operation and cool down. WARNING ! To obtain a French translation of this manual, please contact your dealer or visit www.harmanstoves.com Pour obtenir une traduction française de ce manuel, s’il vous plaît contacter votre revendeur ou visitez www. harmanstoves.com NOTE Contact your local dealer with questions on installation, operation or service. P38+ Use & Care Video

NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

3-90-08422JR11_03/14

save these instructions.

installation & operating Manual

saFetY noticePlease read this entire Manual beFore You install and use Your new rooM heater. Failure to Follow instructions MaY result in ProPertY daMage, bodilY injurY, or even death.For use in the u.s. and canada. suitable For installation in Mobile hoMes.iF this harMan stove is not ProPerlY installed, a house Fire MaY result. For Your saFetY, Follow installation directions. contact local building or Fire oFFicials about restrictions and installation insPection reQuireMents in Your area.contact Your local authoritY (such as MuniciPal building dePartMent, Fire dePartMent, Fire Prevention bureau, etc.) to deterMine the need For a PerMit.cette guide d'utilisation est disPonible en Francais. chez votre concessionnaire de harMan hoMe heating.

Model(s):P38+ Freestanding Pellet Stove

NOTICE: SAVE THESE INSTRUCTIONS

hot glass will cause burns.• Donottouchglassuntilitiscooled• NEVERallowchildrentotouchglass• Keepchildrenaway• CAREFULLYSUPERVISEchildreninsameroomas

stove.• Alertchildrenandadultstohazardsofhightemperatures. high temperatures may ignite clothing or other

flammable materials.• Keepclothing,furniture,draperiesandotherflammable

materialsaway.

hot surFaces!

Glassandothersurfacesarehotduringoperationandcooldown.

WARNING!

To obtain a French translation of thismanual, pleasecontactyourdealerorvisitwww.harmanstoves.com

Pourobtenirunetraductionfrançaisedecemanuel,s’ilvous plaît contacter votre revendeur ou visitezwww.harmanstoves.com

note

Contact your local dealerwith questions on installation,operationorservice.

P38+Use&CareVideo

Page 2: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

3-90-08422JR11_03/14 2P38+PelletStove

"PRE

VENT

HOU

SE F

IRES

"Ins

tall a

nd U

se O

nly in

Acc

orda

nce W

ith M

anufa

cture

r's In

stalla

tion a

nd O

pera

tion I

nstru

ction

s.Co

ntact

Loca

l Buil

ding o

r Fire

Offic

ials A

bout

Restr

iction

s and

Insta

llatio

n Ins

pecti

on in

Your

Are

a.

WAR

NING

: THE

STR

UCTU

RAL I

NTEG

RITY

OF

THE

MANU

FACT

URED

HOM

E FL

OOR,

WAL

L,AN

D CE

ILING

/ROO

F MU

ST B

E MA

INTA

INED

. DO

NOT

INST

ALL I

N SL

EEPI

NG R

OOM.

An ou

tside

comb

ustio

n air i

nlet m

ust b

e pro

vided

. Refe

r to M

anufa

cture

r’s in

struc

tions

and l

ocal

code

s reg

ardin

g the

requ

ireme

nts fo

r pas

sing t

he ex

haus

t ven

ting s

ystem

thro

ugh a

comb

ustib

lewa

ll or c

eiling

.

Inspe

ct an

d Clea

n Exh

aust

Venti

ng S

ystem

Fre

quen

tly.

Use a

3" or

4" di

amete

r typ

e "L"

or "P

L" ve

nting

syste

m.

Do N

ot Co

nnec

t This

Unit

to a

Chim

ney F

lue S

ervin

g Ano

ther A

pplia

nce.

FOR

USE

WIT

H W

OOD

PELL

ET F

UEL O

R UP

TO

50%

COR

N / P

ELLE

T MI

XTUR

E ON

LY.

The U

se of

Othe

r Fue

ls Ma

y Cre

ate an

Uns

afe C

ondit

ion.

Input

Ratin

g Max

: 5.5

lb. fu

el/hr.

U.S.

Elec

trical

Ratin

g: 11

5 VAC

, 60 H

z, St

art 4

.2 AM

PS, R

un 2.

8 AMP

SRo

ute P

ower

Cor

d Awa

y Fro

m Un

it.

DANG

ER: R

isk of

Elec

trical

Shoc

k. Di

scon

nect

Powe

r Befo

re S

ervic

ing U

nit.

For F

urthe

r Ins

tructi

on, R

efer T

o Own

er's

Manu

al.

Repla

ce gl

ass o

nly w

ith 5m

m ce

rami

c ava

ilable

from

your

deale

r.

Keep

View

ing an

d Ash

Rem

oval

Door

s Tigh

tly C

losed

Dur

ing O

pera

tion.

DO N

OT R

EMOV

E TH

IS LA

BEL /

NE

PAS

ENLE

VER

CETT

E ÉT

IQUE

TTE

MINI

MUM

CLEA

RANC

ES T

O CO

MBUS

TIBL

ES/

DIST

ANCE

S DE

SEC

URIT

E PA

R RA

PPOR

T AUX

MATE

RIAU

X CO

MBUS

TIBL

ES:

Back

Wall

/ Entr

e Mur

Arri

ère

2”/ 5

1mm

2”/ 5

1mm

Side

Wall

/ Entr

e Par

oi La

tér

16”/

406m

m 10

”/ 25

4mm

CORN

ER IN

STAL

LATI

ON / E

N AN

GLE

Wall

s to A

pplia

nce

9”/22

8mm

9”/22

8mm

Entre

Mur

s et a

ppar

eilFlu

e Con

necto

r/Rac

cord

à la

chem

inée

3” /

76mm

FLOO

R PR

OTEC

TION

/ Pro

tectio

n Du P

lanch

er

U

SA

Cana

daSi

des*

/Côté

s (A

) 6

” 20

0mm

Back

**/Ar

rière

(B)

6”

200m

mFr

ont*/

Avan

t (C

) 6

” 45

0mm

**Mea

sure

d fro

m pe

desta

l bas

e in t

he U

S ON

LY**M

esur

é à pa

rtir de

la ba

se du

socle

aux É

tats-U

nis un

iquem

ent

*Mea

sure

d fro

m Gl

ass O

penin

g*M

esur

er à

partir

de la

surfa

ce de

la po

rte en

verre

Floor

Pro

tectio

n Mus

t Be a

Non

-Com

busti

ble M

ateria

l.Mu

st Al

so b

e Pl

ace

Unde

r Any

Hor

izonta

l Flue

Con

necto

r, Ex

tendin

g 2” o

r 51m

m Be

yond

the P

ipe M

easu

reme

nt.Po

ur pr

otége

r le pl

anch

er, il

faut s

ous l

e pêo

le un

maté

riau.

Qui

doit a

ussi

être

placé

sous

les p

artie

s hor

izonta

les d

u tuy

au d

e ra

ccor

d à la

chem

inée

et s’é

tendr

e à 51

mm o

2 po.

au-d

elà de

la

mesu

re du

tuya

u.

Made

in U

.S.A

. of U

S an

d imp

orted

parts

. / Fa

briqu

éau

x État

s-Unis

-d’A

mériq

ue pa

r des

pièc

es d’

origi

neam

érica

ine et

pièc

es im

porté

es.

"PRE

VENT

ION

DES

INCE

NDIE

S"Re

spec

ter sc

rupu

leuse

ment

les in

struc

tions

du co

nstru

cteur

pour

l'ins

tallat

ion et

les c

onsig

nes

de fo

nctio

nnem

ent. R

espe

cter le

s règ

les de

sécu

ritè en

vigu

eur d

ans v

otre r

égion

.AV

ERTI

SSEM

ENT

POUR

MOB

ILE H

OMES

: Ne p

as in

stalle

r dan

s une

cham

bre.

ll est

impe

ratif

de pr

évoir

une p

rise d

'alr e

xtérie

ur. L'

intég

rité st

ructu

rale

du pl

anch

er, du

plafo

nd et

des m

urs d

oit ét

restr

ictem

ent p

rése

rvée.

Se re

porte

r aux

instr

uctio

ns du

fabr

icant

et au

x rég

lemen

tation

s spé

cifiqu

esloc

ales c

once

rnan

t les p

réca

ution

s req

uises

lors

de la

trav

ersé

e d'un

mur

ou d'

un pl

afond

.Co

ntróle

r et n

ettoy

er fr

éque

mmen

t tout

le sy

steme

d'ev

acua

tion d

es fu

mées

confo

rmém

ent a

uxre

comm

anda

tions

du co

nstru

cteur.

Utili

ser d

es tu

yaux

<<S

pécia

l gra

nulés

>> de

Ø76

mm

ou10

2 mm.

Ne p

as ra

ccor

der c

e poé

le à u

n con

duit d

e che

miné

e déjà

utilis

é pou

r un a

utre a

ppar

eil.

FONC

TION

NE E

XCLU

SIVE

MENT

AVEC

DES

GRA

NULE

S DE

BOI

S.Ap

pare

il de c

hauff

age à

gran

ulé ty

pe. C

onso

mmati

on m

axim

um: 2

.5 kg

/h.US

coup

ure:

115 V

AC, 6

0 Hz,

4.2 am

ps D

émar

rer, E

xécu

ter 2.

8 AMP

Sfon

ction

neme

nt no

rmal

1.1A.

Tenir

le co

rdon

d'ali

menta

tion à

l'éca

rt du

poèle

.DA

NGER

: Risq

ue d'

électr

ocuti

on. D

ébra

nche

r l'ap

pare

il ava

nt tou

te int

erve

ntion

.Ne

remp

lacer

la vi

tre qu

'avec

une v

itre cé

rami

que 5

mm de

mém

e qua

lité di

spon

ible

aupr

ès de

votre

reve

ndeu

r.Po

ur un

e info

rmati

on pl

us co

mplét

e, se

repo

rter à

la no

tice d

'utilis

ation

. Ten

ir la p

orte

herm

étiqu

emen

t clos

e dur

ant fo

nctio

nnem

ent.

Ne fa

ites p

as ob

stacle

l’esp

ace s

ous l

e réc

hauff

eur. T

oujou

rs fou

rnir u

n app

rovis

ionne

ment

suffis

ant e

n air f

rais

jusqu

’au lie

u d’in

stalla

tion A

pplia

nce

P.N. 3

-90-

0430

0

WIT

HOUT

SIDE

SHI

ELDS

WIT

HSI

DE S

HIEL

DSSa

ns É

crans

Latér

aux

Avec

Écra

nsLa

térau

x

US E

NVIR

ONME

NTAL

PRO

TECT

ION

AGEN

CYTh

is mo

del is

exem

pt fro

m EP

A ce

rtifica

tion u

nder

40 C

FR 60

.531

by de

finitio

n [W

ood H

eater

(A) "

Air-t

o-Fu

el Ra

tio"]

Agen

ce A

méric

aine p

our la

Pro

tectio

n de l

’Env

ironn

emen

tCe

mod

éle es

t disp

ensé

par E

PA ce

rtifica

tion d

’apré

s 40 C

FR 60

.531

par d

èfinit

ion [A

ppar

eil á

bois

(A) <

< Ra

tio ai

r/com

busti

ble>>

]

Date

of Ma

nufac

ture /

Date

de fa

brica

tion:

Fabr

iqué p

ar: H

earth

and H

ome T

echn

ologie

s 352

Mou

ntain

Hous

e Roa

d, Ha

lifax P

A 17

032

2013

20

14

2015

JA

N

FEB

M

AR

A

PR

MAY

JU

N

JUL

AU

G

SEP

OC

T N

OV

DEC

Har

man

PP

38+/

P43

Pel

let S

tove

Bla

ck B

ackg

roun

d w

ith b

are

met

al fo

r prin

t-adh

esiv

e ba

cked

, met

al p

late

.

BARC

ODE

LABE

L00

8Se

rial N

o.No de

série

:

Repo

rt #/

Rapo

rt #1

35-S

-21-

6.2 (P

P38+

)Re

port

#/ Ra

port

#135

-S-2

3-4,

135-

S-23

b-6.2

(P43

)Te

sted t

o / Te

sté à:

ASTM

E15

09-0

4, UL

C/OR

D-C1

482-

M199

0, UL

C-S6

27-0

0

Room

Hea

ter P

ellet

Fuel

Burn

ing Ty

pe. A

lso fo

r use

in M

obile

Hom

es.

Appa

reil d

e cha

uffag

e à gr

anulé

s de b

ois U

tilisa

ble da

ns de

s mob

ile ho

mes.

This

pelle

t bur

ning a

pplia

nce h

as be

en te

sted a

nd lis

ted fo

r use

in M

anufa

cture

d Ho

mes i

n acc

orda

nce w

ith O

AR 81

4-23

-900

thro

ugh 8

14-2

3-90

9

MO

DE

L / M

OD

ÈLE

:

"PP

38+

/

P43

"

2"(5

1mm

)

10" (

254m

m) w

ith s

ide

shie

lds

16" (

406m

m) w

/out

sid

e sh

ield

s

AA

C

B

USA

CA

NA

DA

Flo

or p

ro

tec

tor

PRO

TEC

TiO

N D

E SO

LFL

OO

R P

RO

TEC

TiO

N

9"(2

28m

m)

9"(228mm)3" min

76m

m m

in3"

min

76mm min

Rev

D

10-3

/4"

4-3/8"

The

labe

l sho

wn

here

is fo

r ref

erre

nce

only

. For

spe

cific

info

rmat

ion

on c

lear

ance

s an

d te

stin

g, c

onsu

lt th

e ac

tual

labe

l on

the

rear

of t

he P

38 fu

el h

oppe

r.

Page 3: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

3 PP38+ Pellet Stove 3-90-08422JR11_03/14

SafetyInformation 4

Installation 6

Venting 7

ESPControl 14

Operation 15

DraftTestProcedure 18

Maintenance 19

Troubleshooting 24

Specifications 25

Options 26

Corn/PelletMixture 27

FuelSpecificationDetails 28

WiringDiagram 29

Warranty 30

ServiceParts 32

table of contents

introduction

SafetyListing:Omni-TestLaboratories,Inc.Report#135-S-21-6.2Testedto:ASTME1509-04,ULC/ORD-C1482-M1990,ULC-S627-00

Thisapplianceisalsoapprovedforinstallationintoashop.

Divisionof

Hearth&HomeTechnologies352MountainHouseRoad

Halifax,PA17032

Thislabelislocatedonthebackoftheunit.PleasecopytheSerialNumberforfuturereference.

Serial#:

"PREVENT HOUSE FIRES"Install and Use Only in Accordance With Manufacturer's Installation and Operation Instructions.Contact Local Building or Fire Officials About Restrictions and Installation Inspection in Your Area.

WARNING : THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR, WALL,AND CEILING/ROOF MUST BE MAINTAINED. DO NOT INSTALL IN SLEEPING ROOM.

An outside combustion air inlet must be provided. Refer to Manufacturer’s instructions and localcodes regarding the requirements for passing the exhaust venting system through a combustiblewall or ceiling.

Inspect and Clean Exhaust Venting System Frequently.Use a 3" or 4" diameter type "L" or "PL" venting system.

Do Not Connect This Unit to a Chimney Flue Serving Another Appliance.FOR USE WITH WOOD PELLET FUEL OR UP TO 50% CORN / PELLET MIXTURE ONLY.The Use of Other Fuels May Create an Unsafe Condition.

Input Rating Max: 5.5 lb. fuel/hr.

U.S. Electrical Rating: 115 VAC, 60 Hz, Start 4.2 AMPS, Run 2.8 AMPSRoute Power Cord Away From Unit.

DANGER: Risk of Electrical Shock. Disconnect Power Before Servicing Unit.

For Further Instruction, Refer To Owner's Manual.

Replace glass only with 5mm ceramic available from your dealer.

Keep Viewing and Ash Removal Doors Tightly Closed During Operation.

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE

MINIMUM CLEARANCES TO COMBUSTIBLES/DISTANCES DE SECURITE PAR RAPPORT AUXMATERIAUX COMBUSTIBLES:

Back Wall / Entre Mur Arrière 2”/ 51mm 2”/ 51mmSide Wall / Entre Paroi Latér 16”/ 406mm 10”/ 254mmCORNER INSTALLATION / EN ANGLEWalls to Appliance 9”/228mm 9”/228mmEntre Murs et appareilFlue Connector/Raccord à la cheminée 3” /76mm

FLOOR PROTECTION / Protection Du Plancher USA CanadaSides*/Côtés (A) 6” 200mmBack**/Arrière (B) 6” 200mmFront*/Avant (C) 6” 450mm**Measured from pedestal base in the US ONLY**Mesuré à partir de la base du socle aux États-Unis uniquement*Measured from Glass Opening*Mesurer à partir de la surface de la porte en verre

Floor Protection Must Be a Non-Combustible Material.Must Also be Place Under Any Horizontal Flue Connector, Extending 2” or 51mm Beyond the Pipe Measurement.Pour protéger le plancher, il faut sous le pêole un matériau. Qui doit aussi être placé sous les parties horizontales du tuyau de raccord à la cheminée et s’étendre à 51mm o 2 po. au-delà de la mesure du tuyau.

Made in U.S.A. of US and imported parts. / Fabriquéaux États-Unis-d’Amérique par des pièces d’origineaméricaine et pièces importées.

"PREVENTION DES INCENDIES"Respecter scrupuleusement les instructions du constructeur pour l'installation et les consignesde fonctionnement. Respecter les règles de sécuritè en vigueur dans votre région.AVERTISSEMENT POUR MOBILE HOMES: Ne pas installer dans une chambre. ll est imperatifde prévoir une prise d'alr extérieur. L'intégrité structurale du plancher, du plafond et des murs doit étrestrictement préservée. Se reporter aux instructions du fabricant et aux réglementations spécifiqueslocales concernant les précautions requises lors de la traversée d'un mur ou d'un plafond.Contróler et nettoyer fréquemment tout le systeme d'evacuation des fumées conformément auxrecommandations du constructeur. Utiliser des tuyaux <<Spécial granulés>> de Ø76 mm ou102 mm. Ne pas raccorder ce poéle à un conduit de cheminée déjà utilisé pour un autre appareil.FONCTIONNE EXCLUSIVEMENT AVEC DES GRANULES DE BOIS.Appareil de chauffage à granulé type. Consommation maximum: 2.5 kg/h.US coupure: 115 VAC, 60 Hz, 4.2 amps Démarrer, Exécuter 2.8 AMPSfonctionnement normal 1.1A. Tenir le cordon d'alimentation à l'écart du poèle.DANGER: Risque d'électrocution. Débrancher l'appareil avant toute intervention.Ne remplacer la vitre qu'avec une vitre céramique 5mm de méme qualité disponibleauprès de votre revendeur.Pour une information plus compléte, se reporter à la notice d'utilisation. Tenir la portehermétiquement close durant fonctionnement.Ne faites pas obstacle l’espace sous le réchauffeur. Toujours fournir un approvisionnement suffisant en air frais jusqu’au lieu d’installation Appliance

P.N. 3-90-04300

WITHOUTSIDE SHIELDS

WITHSIDE SHIELDS

Sans ÉcransLatéraux

Avec ÉcransLatéraux

US ENVIRONMENTAL PROTECTION AGENCYThis model is exempt from EPA certification under 40 CFR 60.531

by definition [Wood Heater (A) "Air-to-Fuel Ratio"]Agence Américaine pour la Protection de l’Environnement

Ce modéle est dispensé par EPA certification d’aprés 40 CFR 60.531par dèfinition [Appareil á bois (A) << Ratio air/combustible>>]

Date of Manufacture / Date de fabrication:

Fabriqué par: Hearth and Home Technologies 352 Mountain House Road, Halifax PA 17032

2013 2014 2015 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC

Harman PP38+/P43 Pellet StoveBlack Background with bare metal for print-adhesive backed, metal plate.

BARCODE LABEL008Serial No.No de série:

Report #/ Raport #135-S-21-6.2 (PP38+)Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43)Tested to / Testé à:ASTM E1509-04, ULC/ORD-C1482-M1990, ULC-S627-00

Room Heater Pellet Fuel Burning Type. Also for use in Mobile Homes.Appareil de chauffage à granulés de bois Utilisable dans des mobile homes.

This pellet burning appliance has been tested and listed for use in Manufactured Homes in accordance with OAR 814-23-900 through 814-23-909

MODEL / MODÈLE: "PP38+ / P43"

2"(51mm)

10" (254mm) with side shields16" (406mm) w/out side shields

AAC

B

USA CANADA

Floor protector

PROTECTiON DE SOLFLOOR PROTECTiON

9"(228mm)

9"(228mm

)3" m

in

76mm min3" min

76mm

min

Rev D

10-3/4"

4-3/

8"

= contains updated information

WARNING!do not use cheMicals or Fluids to start the Fire. do not burn garbage or FlaMMable Fluids such as gasoline, naPtha, or oil.

WARNING!do not connect to anY air distribution duct or sYsteM.

Page 4: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

4PP38+ Pellet Stove3-90-08422JR11_03/14

do not install a Flue daMPer in the eXhaust venting sYsteM oF this unit.

do not connect this unit to a chiMneY Flue serving another aPPliance.

Mobile hoMe installation should be done in accordance with the ManuFactured hoMe and saFetY standard (hud), cFr 3280, Part 24.

important notes

installation and rePair oF this harMan stove should be done bY a QualiFied service Person. we recoMMend that the stove be insPected beFore use and at least annuallY bY a QualiFied service Person. Periodic cleaning is reQuired throughout the heating season and at the end oF each winter For the stove to work eFFicientlY. reFer to the Maintenance section oF this Manual.

sPecial note: due to FlY ash builduP, it is stronglY recoMMended that You have Your stove ProFessionallY cleaned and serviced annuallY. this includes all Parts oF the stove, and the entire venting sYsteM.

CAUTION!do not connect to anY air distribution duct or sYsteM.

CAUTION!a chiMneY connector shall not Pass through an attic or rooF sPace, closet or other concealed sPace, a Floor, or a ceiling.

CAUTION!keeP coMbustible Materials (such as grass, leaves, etc.) at least 3 Feet awaY FroM the Flue outlet on the outside oF the building.

CAUTION!the structural integritY oF the Mobile hoMe Floor, wall, and ceiling/rooF Must be Maintained.

CAUTION!Mobile/ManuFactured hoMe standards do not allow installation in rooMs designated For sleePing.

CAUTION!do not use MakeshiFt coMPonents or other coMProMises when installing this aPPliance.

CAUTION!alwaYs be sure there is no unburned Fuel in the ash Pan Prior to lighting a Fire. this will cause sMoke and soot and other unwanted results.

Page 5: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

5 PP38+ Pellet Stove 3-90-08422JR11_03/14

assembly and installationunpackingTheP38 isbolted(1/4x1"hexheadbolts) to theskid topreventmovementduringshipping.Tofreethestovefromtheskidyoumustremovethehold-downboltsintherearofthepedestalbase.removing rear cover panelsTherearcoverpanelsaresecuredtothestovewiththreebolts each.Twoof the bolts need only be loosened, notremoved,toremovethepanels.Itisrecommendedthattherearcoversareinstalledaftertheunitisinplaceandtheventpipeisinstalled,topreventcontactwithhotormovingparts.FirebrickInstallthesinglefirebrickhorizontallyontheanglebracketabovetheburnpot.Flame guideInstallthecastironflameguideontopoftheburnpot.Makesurethattheflameguideisfullyseatedontheverticalsidesoftheburnpotandthatthebackoftheguiderestsagainstthebodyofthestove.INSTALLEXHAUSTVENTATCLEARANCESSPECIFIEDBYTHEMANUFACTURER.Mostpelletventpiperequiresaminimumof3"ofclearancetocombustiblematerialsalthoughsomecanbeinstalledat1"clearance.Followtheseinstructionsalongwithalllocalcodesregardinginstallationofthisappliance.Do not usemakeshift compromiseswhen installing thisappliance,seriousconsequencesmayresult.Withanyhearthappliance,installationofsmokedetectorsisrecommendedoneverylevelofthehome.Possible causes of smoke detector activation:Paintcuringprocess-Openawindowneartheapplianceforthefirstfewhoursofburning.Exhaustbeingdrawnbackinsidethedwelling-Outsideairconnectiontotheapplianceisnecessary.Ventleakage-Allinteriorseamsandjointsshouldbesealedwithsiliconewhereappliacable.Followventmanufacturersinstructionsforpropersealing.

room sensor installationTheroomsensor(part#3-20-00906)isasmalltemperaturesensor on theendof a 60"wire.This sensor is installedmuch likea standardwall thermostat.Use standard18-2thermostatwiretoextendthedistancetothedesiredlocation(50'maximum).Theroomsensorshouldbeinstalledinthelocationwhereyouwanttocontrolthetemperature.NOTE:Distancesofmorethan25feet fromtheunitor inanother roomarenot recommended.The roomsensor isessentialfortheP38'sexcellentefficiency.NOTE: it is recommended that the room sensor be installed,evenifonlyinstalledontherearoftheunitasareturnairsensor.

Rear Cover Panels

Shipping Bolts Note: These same holes are used for securing the stove in mobile home installation.

Fig. 1

Route Room Sensor cable through here.

The Room Sensor cable attaches to two bare terminals on the rear of the circuit board. These connect ions are not polarity specific.

Page 6: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

6PP38+ Pellet Stove3-90-08422JR11_03/14

installing Placethestoveonanoncombustibletypefloororfloorprotectorthatextendsaminimumof6inches(152mm)tothefrontoftheloaddooropening,6inches(152mm)tothesidesofthedooropening,and6 inches to the rear.Floorprotectionmustalsoextend2inches(51mm)beyondeachsideofanyhorizontalfluepipe.Theminimumfloorprotectormaterial is20gaugesheetmetal.Other floor protectormaterials are ceramic tile, stone,brick,etc.note for canadian installation only: PerULC-S627-00,If installed on a combustible floor, the need to provide anoncombustiblefloor protector covering theareabeneath thespace heater andextendingatleast17.72"(450mm)onthefiringsideandatleast7.87"(200mm)ontheothersides.In Canada, you may follow smaller U.S. floor protection requirements onlY if the user agrees to completely shut-down the appliance, and allow it to cool to where all fire is extinguished and the combustion blower and its indicator light shuts off, prior to opening the firebox door or ash door.PlacethestoveawayfromcombustiblewallsatleastasfarasshowninFigures3and4.Pleasenotethedifferenceinsidewallclearancewithandwithoutsideshields.Notethattheclearancesshownareminimumforsafetybutdonotleavemuchroomforaccesswhencleaningorservicing.Pleasetakethisintoaccountwhenplacingthestove.Connect the power cord to a 120 V.A.C. 60Hz groundedreceptacle. (Asurgeprotector is recommended toprotect thecircuitboard.)Alsobesurethatthepolarityoftheoutletthatthestoveispluggedintoiscorrect.Prior to installing the flue pipe, connect a draftmeter. (Thedraftmetermusthaveaminimumrangeof0-.5")Recordthefirstreading.Connectfluepipetostoveandbesurealldoorsandwindowsinthehomeareclosed.Recordtheseconddraftreading_______.Ifthesecondreadingismorethan.05"lowerthanthefirstreading,checkforpossiblerestrictionsortheneedforoutsideair(seepage10).Formoreinformationonthedrafttestprocedure,refertoPage19.Mobile home installationWheninstallingthisunitinamobilehome,severalrequirementsmustbefollowed:1.Theunitmustbeboltedtothefloor.Thiscanbedonewith1/4"

lagscrewsthroughthe2holesinthebaseplate.2.Theunitmustalsobeconnectedtooutsideair.Seepage9.3.Floorprotectionandclearancesmustbefollowedasshown.4.Unitmustbegroundedtothemetalframeofthemobilehome.caution: this appliance must be vented to the outside.Duetohightemperatures,thestoveshouldbeplacedoutoftrafficandawayfromfurnitureanddraperies.Childrenandadults shouldbealerted to thehazardsof highsurfacetemperaturesandshouldstayawaytoavoidburnstoskinand/orclothing.Youngchildrenshouldbecarefullysupervisedwhentheyareinthesameroomasthestove.Clothingandotherflammablematerialsshouldnotbeplacedonornearthisunit.

installation

l

j

Floor Protection requirements US Canada

Sides

Rear

6" 200mm

6" 200mm

k Front 6" 450mm

MinimumSizefloorprotection (USA) is321/2"wideBy33"deep(825mmX838mm).* Floor protection dimensions for the front and sidesare measured from the appliance door opening inThe United States. In Canada, the side dimension ismeasuredfromthewidestpartoftheappliance.

note:Measurement"L"ismeasuredfromthepedestalbaseintheUSONLY

note:Measurement"K"ismeasuredfromtheglassintheUSONLYwarning

the structural integritY oF the ManuFactured hoMe Floor, wall, and ceiling/rooF Must be Maintained.

do not install in sleePing rooM.

Fig. 3

9"(228mm)With or w/Out Side Shields

9"(228mm)

9"(228mm

) Alternate floor protector dimension may be used as long as they satisfy the measurement requirements shown below.M i n u m u m s i z e f l o o r protection for a corner installation hearth pad is 36" x 36". Clearance shown as 9" with optional side shields installed.

Fig. 4

2"(51mm)

36"(914mm)

10" (254mm) with side shields

16" (406mm) without side shields

10" (254mm)16" (406mm)

jusa

k

l

jcanada

Floor protector

Page 7: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

7 PP38+ Pellet Stove 3-90-08422JR11_03/14

venting

requirements for terminating the ventingwarning:Ventingterminalsmustnotberecessedintoawallorsiding.note:Onlyapprovedpelletventpipe,wallpass-throughs,and fire stops should be used when venting throughcombustiblematerials.note:Always take into consideration the effects of theprevailingwinddirectionor otherwind currents thatmaycauseflyashand/orsmokewhenplacingtheterminationofthevent.in addition, the following must be observed:A.Theclearanceabovegrademustbeaminimumof12".B.Theclearancetoawindowordoorthatmaybeopened

must be aminimumof 48" to the side, 48" below thewindow/door, and 12" above thewindow/door. (with outside air installed, 9” to the side or below)

C.A 12" clearance to a permanently closedwindow isrecommendedtopreventcondensationonthewindow.

D.Theverticalclearancetoaventilatedsoffitlocatedabovetheterminalwithinahorizontaldistanceof2feet(60cm)fromthecenter-lineoftheterminalmustbeaminimumof18".

E.Theclearancetoanunventilatedsoffitmustbeaminimumof12".

F. Theclearancetoanoutsidecorneris11"fromcenterofpipe.

G.Theclearancetoaninsidecorneris12".H.Aventmustnotbeinstalledwithin3feet(90cm)above

agasmeter/regulatorassemblywhenmeasuredfromthehorizontalcenter-lineoftheregulator.

I. Theclearancetoserviceregulatorventoutletmustbeaminimumof6feet.

J. Theclearancetoanon-mechanicalairsupplyinlettothebuildingorthecombustionairinlettoanyotherappliancemustbeaminimumof48”.

K.Theclearancetoamechanicalairsupplyinletmustbeaminimumof10feet. (with outside air installed, 6 feet )

L. The clearance above a paved sidewalk or a paveddrivewaylocatedonpublicpropertymustbeaminimumof7feet.

M.Theclearanceunderaveranda,porch,deckorbalconymustbeaminimumof12inches. (b. also applies)

note: The clearance to vegetation and other exteriorcombustiblessuchasmulch is36”asmeasuredfromthecenteroftheoutletorcap.This36”radiuscontinuestogradeoraminimumof7feetbelowtheoutlet.CertainCanadian and/or Local codesor regulationsmayrequiredifferentclearances.Aventshallnotterminatedirectlyaboveaside-walkorpaveddrivewaywhichislocatedbetweentwosinglefamilydwellingsandservesbothdwellings.Onlypermitted ifveranda,porch,deck,orbalcony is fullyopenonaminimumof2sidesbeneaththefloor.see nFPa 211 for more installation clearance reductions when using outside air.note: where passage through a wall, or partition of combustible construction is desired, the installation shall conform to can/csa-b365. (if in canada)

V =Vent Terminal A =Air Supply Inlet =Area where termination is not permitted

Door

Sidewalk

FixedClosed

Openable

Openable FixedClosed

Inside CornerDetail

Porch orOpenable

Deck or Fixed

Page 8: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

8PP38+ Pellet Stove3-90-08422JR11_03/14

venting

ventingA combustion blower is used to extract the combustiongasesfromthefirebox.ThiscausesanegativepressureinthefireboxandapositivepressureintheventingsystemasshowninFig.7.Thelongertheventpipeandmoreelbowsusedinthesystem,thegreatertheflowresistance.Becauseofthesefactswerecommendusingasfewelbowsaspossibleand15feetor lessofventpipe.Themaximumhorizontalrunshouldnotexceed48".Ifmorethan15feetofpipeisneeded,theinteriordiametershouldbeincreasedfrom3"to4"becausealargerpipecauseslessflowresistance.be sure to use approved pellet vent pipe wall and ceiling pass-through fittings to go through combustible walls and ceilings. all joints for connector pipe must be fastened with a minimum of three screws and a termination cap must be installed. Follow pellet vent manufacturer instructions for properly securing each pellet vent joint. the pellet starting collar must be secured to the unit's flue collar.a chiMneY connector MaY not Pass through an attic or rooF sPace, closet or siMilar concealed sPace, Floor , or ceiling. reFerence local building codes For details.

iMPortant noticeApproved3"or4"PelletVentPipeSuchAs,Type"PL",MustBeUsed.

Fig. 7

vent PipePelletventingpipe(knownasPLvent)isconstructedoftwolayerswithairspacebetweenthelayers.Thisairspaceactsasaninsulatorandreducestheoutsidesurfacetemperaturetoallowaclearancetocombustiblesof1inch.Thesectionsofpipelocktogethertoformanairtightsealinmostcases.However,insomecasesaperfectsealisnotachieved.Forthisreasonandthefactthattheunitoperateswithapositiveventpressurewe specify that the joints also be sealed with high temp (rtv) silicone. Aluminumtapecanalsobeusedforanyjointthatis1ft.ormorefromtheoutletofthestove.note: simpson duravent Pelletvent Pro harman adapter Part #3PvP-adhb and Pelletvent Pro harman adapter increaser Part #3PvP-X4adhb are highly recommended to be installed on the starter collar to insure a proper pipe connection to the unit.install vent at clearances sPeciFied bY the vent ManuFacturerdo not install a Flue daMPer in the eXhaust venting sYsteM oF this unit.do not connect this unit to a chiMneY Flue serving another aPPliance

avoiding smoke and odorsnegative Pressure, shut-down, and Power Failure:To reduce the probability of back-drafting or burn-back in the pellet burning appliance during power failure or shut-down conditions, the stove must be able to draft naturallywithoutexhaustbloweroperation.Negativepressureinthehousewillresistthisnaturaldraftifnotaccountedforinthepelletapplianceinstallation.Heatrisesinthehouseandleaksoutatupperlevels.Thisairmustbereplacedwithcoldairfromoutdoors,whichflowsinto lower levels of the house.Vents and chimneys intobasementsandlowerlevelsofthehousecanbecometheconduitforairsupply,andreverseundertheseconditions.outside air:hearth & home technologies strongly recommends attaching outside air in all installations, especially lower level and main floor locations.

do not use MakeshiFt coMProMises when installing this aPPliance. daMage and/or injurY MaY result.

CAUTION!

O+ = Positive static pressure= Negative static pressureO-

+

+

Page 9: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

9 PP38+ Pellet Stove 3-90-08422JR11_03/14

Pernationalbuildingcodes,considerationmustbegiventocombustionairsupplytoallcombustionappliances.Failuretosupplyadequatecombustionairforallappliancedemands,mayleadtoback-draftingofthoseandotherappliances.Whentheapplianceisside-wallvented:Theairintakeisbestlocatedonthesameexteriorwallastheexhaustventoutletandlocatedloweronthewallthantheexhaustventoutlet.When theappliance is roofvented:Theair intake isbestlocatedontheexteriorwallorientedtowardstheprevailingwinddirectionduringtheheatingseason.Theoutsideairconnectionwillsupplythedemandsofthepellet appliance, but considerationmust be given to thetotalhousedemand.Housedemandmayconsumesomeairneededforthestove,especiallyduringapowerfailure.Itmaybenecessarytoaddadditionalventilationtothespaceinwhichthepelletapplianceislocated.ConsultwithyourlocalHVACprofessionaltodeterminetheventilationdemandsforyourhouse.Toinstalloutsideairuse3"non-combustibleflexpipe.Thereisabreak-awayholeontherearpanelofthestovewhichmustberemovedbeforeconnectingtheflexpipe.Thepipeshouldberunoutsideandterminatetothesideorbelowtheventpipeoutletsotheflueoutletismorethan12"fromtheinletcover.Themaximumlengthrunofthispipeis15feet.Inletcover,partnumber1-10-09542shouldbeusedtokeepbirds,rodents,etc.outofthepipe.Youmay choose to use the optional Direct VentWallPassthroughKit(part#1-00-677177)whichincorporatestheventingpassthroughandoutsideairinletintoonecomponent.

venting

Outside air flex pipe goes here.

Inlet Cover part# 1-10-09542

Direct Vent Wall Passthrough Kit (part #1-00-677177)

Vent Configurations:Toreduceprobabilityofreversedraftingduringshut-downconditions,Hearth&HomeTechnologiesstronglyrecommends:• Installingthepelletventwithaminimumverticalrunoffivefeet,preferablyterminatingabovetheroofline.• Installingtheoutsideairintakeatleastfourfeetbelowtheventtermination.Topreventsootdamagetoexteriorwallsofthehouseandtopreventre-entryofsootorashintothehouse:• Maintainspecifiedclearancestowindows,doors,andairinlets,includingairconditioners.• Ventsshouldnotbeplacedbelowventilatedsoffits.Runtheventabovetheroof.• Avoidventingintoalcovelocations.• Ventsshouldnotterminateunderoverhangs,decksorontocoveredporches.• Maintainminimumclearanceof12inchesfromtheventterminationtotheexteriorwall.Ifyouseedepositsdeveloping

onthewall,youmayneedtoextendthisdistancetoaccommodateyourinstallationconditions.hearth & home technologies assumes no responsibility for, nor does the warranty extend to, smoke damage caused by reverse drafting of pellet appliances under shut-down or power failure conditions.

Page 10: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

10PP38+ Pellet Stove3-90-08422JR11_03/14

#2 Preferred method Thismethod also provides excellent venting for normaloperationbutrequiresthestovetobeinstalledfartherfromthewall.Theverticalportionoftheventshouldbethreetofivefeethighandatleastthreeinchesfromacombustiblewall.Thisverticalsectionwillprovidenaturaldraftintheeventofapowerfailure.If the stove is installed below grade be sure the venttermination is at least 12" above grade. The outlet must also be 1 foot from the house/building. Note: Do not place joints within wall pass-throughs.

#1 Preferred method Thismethodprovidesexcellentventingfornormaloperationandallowsthestovetobeinstalledclosesttothewall.Twoinches from thewall is safe; however, four inchesallowsbetteraccesstoremovetherearpanel.Theverticalportionoftheventshouldbethreetofivefeethigh.Thisverticalsectionwillhelpprovidenaturaldraftintheeventofapowerfailure.note: do not place joints within wall pass-throughs.

venting

Fig. 8

Fig. 9

CAUTION!keep combustible materials (such as grass, leaves, etc.) at least 3 feet away from the flue outlet on the outside of the building.

3 Ft.to

Combustibles

3 Ft.to Combustibles

3 Ft.to

combustibles

3 Ft.to combustibles

Page 11: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

11 PP38+ Pellet Stove 3-90-08422JR11_03/14

#4 installing into an existing chimney Thismethodprovidesexcellentventingfornormaloperation.Thismethodalsoprovidesnatural draft in theevent of apowerfailure.Ifthechimneyconditionisquestionable*youmaywanttoinstallalinerasinmethod#7.InsomeplacesintheUSandCanadaitisrequiredthattheventpipeextendallthewaytothetopofthechimney.*The chimney should be inspected and cleaned beforeinstallingyourstove.Ifyoudiscoverthatthechimneydoesnothaveaclaytilelinerorhascracksorflakingofthetileliner youwill need to install a stainless steel linerwithinthechimney.Inmostcasestheinsidediameterofthislinershouldbe4".Eitherflexibleorrigidlinermaybeusedforthispurpose.RefertoMethod6&7.Besuretodesigntheventingsothatitcanbeeasilycleaned.

#5 Installing into an existing fireplace chimney Thismethodprovidesexcellentventingfornormaloperation.Thismethodalsoprovidesnatural draft in theevent of apowerfailure.Ifthechimneyconditionisquestionable*youmaywanttoinstallalinerasinmethod#6.InsomeplacesintheUSandCanadaitisrequiredthattheventpipeextendallthewaytothetopofthechimney.*The chimney should be inspected and cleaned beforeinstallingyourstove.Ifyoudiscoverthatthechimneydoesnothaveaclaytilelinerorhascracksorflakingofthetileliner youwill need to install a stainless steel linerwithinthechimney.Inmostcasestheinsidediameterofthislinershouldbe4".Eitherflexibleorrigidlinermaybeusedforthispurpose.RefertoMethod6&7.The chimney should be sealed at the damper using asteel plate.Kaowool,mineralwool or an equivalent non-combustibleinsulationisrecommendedtobeinstalledontopofthesealingplatetoreducethepossibilityofcondensation.The connector pipe should extend through the smokechambertothebaseorintothefirstfluetile.Besuretodesigntheventingsothatitcanbeeasilycleaned.

Fig. 10

Fig. 11

venting

Page 12: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

12PP38+ Pellet Stove3-90-08422JR11_03/14

#6 Installing into an existing fireplace chimney Thismethodprovidesexcellentventingfornormaloperation.Thismethodalsoprovidesnatural draft in theevent of apowerfailure.InsomeplacesintheUSandCanadaitisrequiredthattheventpipeextendallthewaytothetopofthechimney.Thepipeorlinerinsidethechimneyshouldbe4"diameter.Inthismethodacapshouldalsobeinstalledonthechimneytokeepoutrain.Besuretouseapprovedpelletventpipefittings.Sealpipe jointswithsiliconeoraluminum tape inadditiontothesealingsystemusedbythemanufacturer.Pipesizeshouldbeincreasedto4"usingthismethod.

#7 installing into an existing chimney Thismethodprovidesexcellentventingfornormaloperation.Thismethodalsoprovidesnatural draft in theevent of apowerfailure.InsomeplacesintheUSandCanadaitisrequiredthattheventpipeextendallthewaytothetopofthechimney.Thepipeorlinerinsidethechimneyshouldbe4"diameter.Inthismethodacapshouldalsobeinstalledonthechimneytokeepoutrain.

venting

Fig. 12

Fig. 13

Page 13: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

13 PP38+ Pellet Stove 3-90-08422JR11_03/14

12"min. wall to outlet

36"

min. clearance to any

combustible material

12"

min

. abo

ve g

roun

d le

vel

PL vent manufacturer's �restop spacer and support

1" MIN.

No insulation or othercombustible materialsare allowed within 3"of the PL vent pipe.

�ashing

storm collar

1" MIN.

1" MIN.

12" M

IN

1” MIN.

#8 installing through the ceilingThrough the ceiling vent, followPL ventmanufacturersrecommendationswhenusingwallandceilingpassthrough. note: do not place joints within wall pass-throughs.

Fig. 14

venting

Fig. 15

Fig. 16

Minimum flue vent configurationIt is recommended that outsideair be installed with this ventingconfiguration.

Area within dotted circle represents the minimumclearance to combustiblematerials suchasshrubbery,mulchortallgrasses.

Page 14: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

14PP38+ Pellet Stove3-90-08422JR11_03/14

esP control

status light error Messages3-blinks: IndicatesthattheESPhasgoneoutofrangetoomanytimes.Couldbeanindicatorofbuildupofash,etc.inthefluepipeorheatexchange.PerformaManualReset.4-blinks: Indicates that the room sensor circuit is notcomplete. May mean a poor connection or short in thesensorwire.(Willonlyoccurin"RoomTemp"mode.)

Feed adjusterSets the maximum feed rate

TestRuns all motors at full speed for one minute to check operat ion. Afterwards, the control will simulate a minimum burn and the combustion blower will remain on low for draft test convenience.

Distribution Blower s p e e d a d j u s t m e n t range. L = lowH = highVariable speed anywhere b e t w e e n L a n d H ; although as the stove temp. goes up, so does the low end of the scale.

Temperature Dial;Allows you to adjust the room temperature in Room Temp Mode using the outer scale marked in degrees Fahrenheit. It also allows you to adjust the stove temperature while in Stove Temp Mode using the inner scale marked from 1 to 7.

Mode Selector Allows you to choose between Room Temp Mode, Stove Temp Mode, or OFF. Also allows you to vary the distribution blower speed by turning the knob to the high or low side of each mode.

Power LightIndicates power to the control.

Indicates power to the feed motor.

Indicates power to the combustion blower

Status LightWill be lit in either stove or room temp mode when pointer is not within off position band except after normal shut down. Blinks to indicate errors listed below.

Indicates power to the distribution blower.

Dealer Diagnostic PortFor dealer maintenance only. Requires special DDM monitor supplied to Harman Dealers exclusively.

6-blinks: Indicates the control hasmeasured incompletecombustionocurring formore than25minutes.Thiserrormay be set if the feed system runs out of fuel. Turn thecontrolto"OFF"andbacktothedesiredmodetoresumeoperation.Ifthelackoffuelwasnotthecause,refertothetroubleshootingsection.Manual reset: Turn the mode selector to "OFF", anddisconnectpowerforasecond.Restorepowerandreturntooriginalsetting.

Page 15: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

15 PP38+ Pellet Stove 3-90-08422JR11_03/14

operation

TheP38+featurestwooperatingmodes;stove temperature Modeandroom temperature Mode.InStoveTemperatureMode,youselectaburnrateandthestovewillremainatthesameburnrateregardlessoftheroomtemperature.IntheRoomTemperatureMode,withtheoptionalroomsensorattached,thestoveconstantlymonitorsthetemperatureintheroomandadjuststhesizeofthefireandtheheatoutputofthestovesothattheroomiskeptataconstanttemperature.room temperature Mode Mostconsumersuse thestove in theRoomTemperatureModebecause it is theeasiestandmostefficientmethodofkeepingtheroomatagiventemperature. In theRoomTemperatureMode, theRoomSensingProbe constantlymonitorsroomtemperature.Astheweatherchangesoutsideandyourhomeneedsvaryingamountsofheat tobeatadesired temperature, thestovewillautomatically increasefiresizeandheatoutputsothataconstanteventemperatureismaintained. If theweatherwarms up and no heat isrequired,thestovewillgraduallyslowdownandholdattheminimumburnrate.Whenthehousecoolsdown,thestovewillautomaticallybringtheroomtemperaturetotheprecisetemperatureyoudesire.IntheRoomTemperatureMode,thedistributionblowerspeedcanbeincreasedordecreasedbyadjustingtheRoomTemp/Off/StoveTempdialbetweenLandH.Asoutputofthestoveincreases,thespeedoftheblowerwillincreaseautomaticallytoinsurethatmoreheatistransferredintotheroom.

room temperature Mode: This setting, see above,will produce a room temperature of 70 degreeswith thedistributionbloweratmediumspeed.

CAUTION!do not use cheMicals or Fluids to start the Fire. For eXaMPle: never use gasoline, gasoline-tYPe lantern Fuel, kerosene, charcoal lighter Fluid, or siMilar liQuids to start or "Freshen uP" a Fire in this heater. keeP all such liQuids well awaY FroM the heater while it is in use.

CAUTION!do not connect to anY air distribution duct or sYsteM. do not burn garbage or FlaMMable Fluids such as gasoline, naPtha, or engine oil.

hot while in oPeration. keeP children, clothing, and Furniture awaY. contact MaY cause skin burns.

keeP FireboX and ash reMoval doors closed during oPeration. Maintain seals in good condition.

room temperature Mode

Page 16: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

16PP38+ Pellet Stove3-90-08422JR11_03/14

operation

The setting above will produce continuous maximum heat output with the distribution blower at full speed.

stove temperature Mode

The setting above will produce continuous medium heat output with the distribution blower at low speed.

stove temperature ModeIntheStoveTemperatureMode,thestovecanbeadjustedtothedesiredsettingusingthesametemperaturecontroldialasisusedintheRoomTemperatureMode.Theheatoutputandfuelconsumptionwillremainconstantregardlessofroomtemperature.Thesettingsfrom1to7ontheinnerringofthetemperaturedialprovideforrelativeheatoutputsettingswith1beinglowand7beingthemaximum.Neverpulltheplugtoshutdownthestove.Thiswillstopthecombustionblowerandsmokewillescapethroughwindowanddoorgaskets.Feed adjuster knobFormostpremiumgradepelletfuelstheFeedAdjusterKnobshouldbesetat4.Ifhigherashfuelsareusedthesettingshould be increased to 5 or 6.Also higher settings arerequiredifyouwouldliketogetthemaximumheatoutputfromthestove.Atthemaximumburnrate(withthetemperaturedialon7/90°andthefeedadjusterat6)thereshouldbe1"ormoreofashonthefrontoftheburnpot.Ifthereislessthan1"ofash,turnthefeedadjusterknobdowntoalowersetting.shut down ProcedureThe bestway to shut down the stove is to simply let itrunoutofpellets.Thestovewillshutdownautomatically.Alternatively,youcanturntheModeSelectorto“off”.Thiswillcausethefiretograduallydiedownandgoout.Thefirewillnotgooutimmediatelyandmaytakemorethananhourtofullyshutdown,dependingontheburnrate.Ifthestoveislefttorunoutoffuel,youmaygeta6blinkstatuslight.Ifthishappens,simplyresetthecontrolboardbyturningthemodeselectortoOFFandbackON.

CAUTION!hot while in oPeration. keeP children, clothing, and Furniture awaY. contact MaY cause skin burns.

Page 17: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

17 PP38+ Pellet Stove 3-90-08422JR11_03/14

starting First FireMakesuretheunitispluggedintoa100VAC,50Hzelectricalsource.Thepowerlightshouldbetheonlylightlit.

operation

1. Fines are small pieces of broken pellets (sawdust). Fines do not flow easily and often build up on the hopper funnel bottom angles. You can push these fines into the feeder opening and then fill the hopper with pellets. As the system works, they will be burned. Or you can clean them out before filling the hopper.

2. The "TEST" cycle will operate the feeder motor for exactly one minute. Turning to "TEST" again and again may load too much fuel into the burn pot causing excessive smoke on start-up.

3. The firebox low pressure switch will not allow the auger motor to operate if the view door or the ash pan door are open.

4. Adjust Feed Rate. If this is your first fire or you are trying different pellets, set the feed adjuster to #4, Fig. 17. This is a conservative number and will probably need to be increased. After you know a feed rate setting that works well, use that setting. Remember, if your feed rate is too high you may waste fuel.

5. This is usually a weekly maintenance procedure. Cleaning the burn pot with the scraper with a small amount of new fuel in the bottom is not a problem. First, scrape the ashes off the front of the burn pot into the ash pan. Then, scrape the top surface of the burn pot downward into the base of the burn pot. When the stove is ignited these scrapings will be pushed out by the feeder and burned.

6. The ash pan can hold the ashes from approximately 1 ton of premium fuel. This means the ashes will only need to be emptied a few times a year.

7. Allow the unit to burn for about 30 minutes and check ash on front of burn pot. Fig. 18. If the ash line is larger than 1", turn the feed adjuster from #4 to #5. Allow another 30 minutes of burn time and check again. If , at #6 setting, a 1" or less ash bed is not obtainable, it is not a problem. The 1" ash bed is only a maximum burn rate and at most normal settings the ash bed will be larger.

Fig. 17

notice: be sure there is no unburned fuel or other combustibles in the ash pan prior to lighting.

1. turn Feed adjuster to desired feed rate.No.4isgoodformostpellets.

2. turn the Mode selector to “oFF” and then to the desired mode.Thiswill resetcontrolandstart thecombustionmotor.

3. turn the teMPerature dial to the desired setting.4. clean burn pot with scraper if necessary.5. Fill burn pot with pellets, only level with front edge.

(DoNotOverFill).6. add starting gel on top of the pellets.Stirgelintopellets

forfastlighting.7. light starting gel with a match, and close the door.

Operationwill beginwhen the fire reaches the propertemperature.

8. Fill hopper with pellets and remove ashes as required.keeP the aPPliance doors and hoPPer lid closed during oPeration.

Fig. 18

STARTER GEL

See Hint #71"

Page 18: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

18PP38+ Pellet Stove3-90-08422JR11_03/14

Asimple draft test should beperformedbefore andaftercompletingthefluepipeinstallation.Tocompareandtorecordtheresultsforfuturereference:1.Plugtheunitintoa100VAC,50Hzoutlet.2.Closethehopper lid, frontviewdoor,andtheashpan.

Neitherpelletsorafirearerequiredforthistest.3.Withthemodeselectorinthe"OFF"position,turnthefeed

adjusterto"TEST".4.Record thehighdraft______inW.C. (Normal is -.50 to

-.60)ThecontrolwillbeontheHighDraftforaminute.5.After1minute,thecombustionmotorwillgodowntolow

draft and thedistributionblowerwill goonhigh.Allowapproximately 15 seconds to pass for the combustionmotortoslowbeforecheckingthelowdraft.

6.Ifthelowdraftisbetween-.25and-.35,recordthereading_____inW.C.

If thereading is lower,checkforresistance in theventingconfiguration.Toomanyelbows,orexcessivehorizontalrunswilladdresistance.Also,besurethedoorsandhopperlidareproperlysecured.As longas thedraft reading dropswhen the combustionblowergoestolowspeed,higherreadingsarenotanissue.Longverticalrunscanactuallyincreasethereadingsduetotheadditionofnaturaldraft.Ifthedraftreadingdoesnotdrop,thereislikelyrestrictionontheairintake.Besuretheintakeflapperisopeningandcheckforresistanceintheoutsideairconduitifinstalled.

draft test Procedure

Fig. 23

Draft Meter bolt hole locationOn a PP38 the draft test hole is under the left rear corner of the firebox.

Page 19: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

19 PP38+ Pellet Stove 3-90-08422JR11_03/14

MaintenanceMinimizing creosote:Wheneverwoodisburnedslowly,thepotentialexistsforcreosotetoformintheventing.Thechimneyorventingsystemshouldbeinspectedperiodicallythroughouttheheatingseasontodetermineifacreosotebuilduphasoccurred.Ifasignificantlayerofcreosotehasaccumulated(3mmormore),itshouldberemovedtoreducetheriskofachimneyfire.Aprofessionalchimneysweepisrecommended,sincetheywouldnormallyhavethecorrectequipmenttoensurepropercreosoteremoval.

If you experience a fire in the venting system,turnthestoveto"OFF"toallowtheunittoshutdown.Callthefiredepartment,andbesureeveryoneisoutoftheresidence.Beforere-usingtheappliance,haveit,andtheventingsystemthoroughlyinspectedandreplaceanydamagedcomponents.

The glass in your Harman stove is a special 5mmceramicglass.• Donotabusetheglassbystrikingorslammingthe

door.• Neverburntheapplianceifthedoorglassiscracked

orbroken.• ReplaceonlywithHarmansuppliedglass.DoNOT

UseSubstitutes.Soot and/or fly-ash may accumulate on the viewingglass,andwillocassionallyneed tobecleaned.Cleantheglasswithasoftclothandmildglasscleaner.Donotcleantheglasswhenhot,andavoidtheuseofabrasivecleaners.

GlassreplacementCarefully remove all remaining glass and gasketmaterialspriortoreplacingtheglass.

Lay thedoor facedownonaflatsurface.Remove theglass retainers and screws.Apply the gasketmaterialto the face of the new glass. Lay the glass into thedoor,makingsurethattheglassiscontainedwithinthechannelsandraisedareasofthedooritself.Laytheglassretainersintopositionandinstallthescrews.Tighteneachscrewevenlytoavoidmakinganystresspoints.

RetainersandscrewsGlass

Adhesivegasket

DoorFrame

insPect aPPliance and coMPonents For daMage. daMaged Parts MaY iMPair saFe oPeration.• do not install daMaged

coMPonents.• do not install incoMPlete

coMPonents.• do not install substitute

coMPonents.rePort daMaged Parts to dealer.

Fire risk.hearth & hoMe technologies disclaiMs anY resPonsibilitY For, and the warrantY will be voided bY, the Following actions:

• installation and use oF anY daMaged aPPliance.

• ModiFication oF the aPPliance.• installation other than as instructed bY

hearth & hoMe technologies.• installation oF Parts or coMPonents not

suPPlied or aPProved bY hearth & hoMe technologies.

• oPerating aPPliance without FullY asseMbling all coMPonents.

or anY such action that MaY cause a Fire hazard.

WARNING! WARNING!

Page 20: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

20PP38+ Pellet Stove3-90-08422JR11_03/14

Maintenancescraping the burn pot:Whenever adding fuel to the hopper, take the time andscrapethegratesurfaceoftheburnpot,usingthescrapertoolprovided.Thiscanbedonewhileafireisburning.Wearingheatresistantgloves,openthefireboxdoor.Scrapeanyaccumulatedashesfrominfrontofthefire,intotheashpan.Now,scrapeunderthefire,inadownwarddirection,toloosenanycarbondeposits.Donotscrapethefireoutofthepot.Whateveryouloosenwillbepushedoutwiththeflowofnewfuelintothepot.removing ashes:Afterapproximately1tonofpelletshasbeenburned,itwillbenecessarytoemptytheashpan.disposal of ashes- ashes should be placed in a steel container with a tight fitting lid. The closed container of ashes should be moved outdoors immediately and placed on a noncombustible floor or on the ground, well away from all combustible materials, pending final disposal. if the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have been thoroughly cooled. other waste shall not be placed in this container.cleaning:Itisrecommendedthatthestoveiscoldandshutdownwhenremovingtheashpan.1.Lift the latchhandle toopen theashdoorand remove

theashpan.Useashpanhandletocarryanddisposeofashes.

2.Slidetheashpanbackintothestoveandlatchthedoorbypushingdownonthelatchhandlewhenclosed.

cleaning:Thestoveshouldbeshut-downandthoroughlycleanedaftereach tonofpelletsconsumed.Thecleaner thestove, themoreefficientitwillbe.note: Fuelwith higher ash and/ormoisture contentwillrequiremorefrequentcleanings.1.Shut down the stove anddisconnect power cord to

insurethatallmotorsarestopped.2.Cleanheatexchangerwithscraperasshowninfig27.3.Brushorscrapetheinsideofthestovetoremoveflyash.4.Scrapeburnpotwithflatendofscraperprovidedwiththe

stove.Inspecttheholesontheburnpotsurface.SeeFig.33.

5.Openburnpotclean-out.Cleanflyashfromburnpotandreplacecover.

Combustion Blower Cover

Blower Cover Latch

Fig 26

Scraper

Blower Cover Latch

Blower Wheel

Flue Outlet

Heat Exchanger Fins

Fig 27

Page 21: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

21 PP38+ Pellet Stove 3-90-08422JR11_03/14

Maintenance6.Removetheashpanandproperlydisposeoftheashes.7.Removecombustionblowercoverbyturningtheblower

coverlatchvertical,seeFig.26.Slidingthecoveroutoftheslotontheleft.Thiswillexposethecombustionblowerwheelandflueoutlet,Fig.27.

8.Cleanthecombustionblowerwheelwithabrushandavacuumcleaner.Note:Donotuseahouseholdvacuumtocleanthestove.Werecommendthatyouuseashopvacuumthat isequippedwithafinedustfiltercalledaHEPAfilteroravacuumspeciallymade forashesandsoot.using a vacuum which is not equipped with a fine dust filter may clog and disperse fly ash and soot into the room.

note: the stove Must be coMPletelY out beFore You vacuuM the stove. live Pellets, iF sucked into the vacuuM will light the vacuuM on Fire and MaY ultiMatelY cause a house Fire.9.Useabrushtocleantheflue,beingcarefulnottodamage

theESP,seeFig.30.Thefluegoesstraightthroughintotheventpipe(Fig.27)therefore,theventpipecanalsobecleaned,tosomeextent,throughtheflueoutlet.

10.Reinstalltheblowercoverandclosethelatch.11. Slidetheashpanintostoveandlatchthedoor.soot and Fly ashFormation and need for removal - The products ofcombustionwillcontainsmallparticlesofflyash.Theflyashwillcollectintheexhaustventingsystemandrestricttheflowofthefluegases.Incompletecombustion,suchasoccursduringstartup,shutdown,orincorrectoperationoftheroomheaterwillleadtosomesootformationwhichwillcollectintheexhaustventingsystem.the exhaust venting system should be inspected at least once every year to determine if cleaning is necessary.Removingflyashandsootimprovesefficiencyandinsuresthattheflueventingpassagewayisclearandunobstructed.Thestoveshouldbecleanedaftereachtonofpellets(50bags)andtheventingsysteminspectedandcleanedaftereachheatingseason.

Exposedblowerwheelandflueopening,NOTE:ESPisvisible.

ESP

Fig. 30

Burn pot Clean-out plate

Latch "open "with blowercoverpartlyremoved.Burnpotclean-outisopen.

Latch"closed"withblowercover in place. Burn potclean-outisclosed.

Blowercoverremoved.

Fig. 29Fig. 28

Fig. 31

ESP

Be careful not to damage the ESP when cleaning with brush.

Page 22: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

22PP38+ Pellet Stove3-90-08422JR11_03/14

burn Pot cleaning and Maintenance1. Scrapethetopholedsurfaceandsidesoftheburnpot.

(Fig 33) It is not necessary to completely remove allmaterialfromtheburnpot.Theexcesswillbepushedoutduringthenextuse.

2. Loosenthe(2)wingthumbscrewsonthelowerfrontangleoftheburnpot.(Fig.34)

3. Liftofftheclean-outcovertoopenthebottomclean-outchamber.

4. Cleanashbuildupfrominsidethechamberwhilecoverisoff.Usethescrapertotaponthetopfrontedgeoftheburnpot.Thiswillhelpknockpiecesofash,loosenedbythescrapingprocess,downthroughtheholes.

5. Besurethecover is inplaceonthescrewsandhand-tightenthewingscrews.

Maintenance - burn Pot

Fig. 34

dANGeR!disconnect the power to the unit before removing cover.

Fig. 33

Wing Thumb Screws

Page 23: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

23 PP38+ Pellet Stove 3-90-08422JR11_03/14

Maintenance - cleaning the Feeder bodyPelletfinesmayaccumulateinthefeederbodyoveraperiodoftime;therefore,ayearly inspectionandcleaningofthisareamustbeperformed.Tocleanoutfines:1. Removetherearcoverpanels.2. Removewingnutand feeder coveron thesideof the

feeder.3. Useavacuumcleanertoremoveallfines.4. Reinstallfeedcover,wingnut,andrearcoverpanels.

5/16" Hex Head Screws (2 on each side)

5/16" Hex Head Screws (2 on each side)

safety FeaturesThelowdraftsensorwhichisavacuumdifferentialswitch,monitorsthenegativepressure(draft)inthefireboxthroughaportontherearofthefeeder.Poordraftwillresultinaninterruptionofpowertothefeedermotor.Poordraftcanbecausedbyblockageintheexhaust,excessivebuild-uponthecombustionblowerfanblades,afailedcombustionblower,oradoororotheropeningtothefireboxnotsealedproperly.Thecircuitboardismonitoringthepositionofthisswitch.Duringafeedcycle,ifthisswitchweretoopen,thefeedmotorlightonthecontrolwillstayilluminatedwiththepowerbeinginterruptedbytheswitch.Iftheswitchopenswhenthecycleisatrest,thepowerlightforthefeedmotorwillnotilluminate.Besurealldoors,includingthehopperlid,aresecurelyclosedwhenoperatingtheappliance.

Pellet Fines may build up in this area

Low Draft Sensor

Air Intake Flapper

Page 24: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

24PP38+ Pellet Stove3-90-08422JR11_03/14

sMoke is visible coMing out oF vent1. Air-fuelratioistoorich.

a.Feedratetoohigh.b.Drafttoolowcausedbyagasketleak.

low heat outPut1.Feedratetoolow2.Drafttoolowbecauseofgasketleak.3.Poorqualityordamppellets4.Combinationof1and2.

trouble-shooting

helpful hintscleaning burn PotWheneveryourstoveisnotburning,taketheopportunitytoscrape theburnpot to removecarbonbuildup.Avacuumcleanerishandytoremovetheresidue.be sure the stove is cold if you use a vacuum.Carbonbuildupcanbescrapedloosewiththefireburningusingthespecialtoolprovidedwithyourstove.Scrapethefloorandsidesoftheburnpot.Thecarbonwillbepushedoutbytheincomingfuel.Alwayswearglovestodothis.removing ashesTurntheTempDialtonumber1approximately30minutesbeforeremovingashes.Thiswillresultinacoolerstoveandashpan.MaximumFeedAdjuster settingsarenot needed inmostcases.Operatinginthenormalrange(#4)isrecommendedwhenmaximumheatoutputisnotrequired.TheESPcontrolpreventsthestovefrombeingover-fired.Keepthestovefreeofdustanddirt.

stove does not Feed1. Nofuelinhopper.2. Fireboxdraftmaybetoolowforsensingswitchinfeeder

circuit to operate.check for closed doors, loose ormissinggasketondoorsorhopperlid.

3. Feedmotorwillnotrununtil theESPcontrolsensesacertaintemperature.Maybeyoudidnotputenoughfuelorstartinggelintheburnpotbeforemanuallylightingthefire.

4. Restrictioninthehopperorfeeder.Removeallfuelandexamine.Cleartheobstruction.

5. Feedmotorhasfailed.PartiallY burned Pellets1. Feedratetoohigh.2. Poorairtofuelmixture.(Checkburnpotclean-outcover

andairintake).3. Burnpotorheatexchangertubesmayneedtobecleaned.4. Combinationofalltheabove.5. #6 status blink:A6blinkcontrolboardstatusindication

iscausedbypoororincompletecombustion.ThecircuitboardhastheabilitytotrackthecombustionthroughfeedsettingsandESPtemperatures.Whenthecontrolboardhascalculatedpoororincompletecombustion,itwillshutdown theunitasasafety feature. (Pooror incompletecombustionisacontributorofcreosotewhichmaycauseachimneyfire)

a 6 blink status may be caused by several things:1. Blockedorpartiallyblockedflue.2. Blockedorpartiallyblockedinletair.

a.Backdraftdamperontheinletpipemaybestuckclosed.b.Ifoutsideairisinstalled,theinletcovermaybeblocked.

3. Theairchamberundertheburnpotmaybefilledwithfinesandsmallbitsofash.

4. Theholesintheburnpotmaybegettingfilledwithashorcarbonbuildup.

5. Combustionblowerfanbladesmayneedcleaned.6. Fuelrestrictionsasnotedabove.sMoke sMellSealtheventpipejointsandconnectiontostovewithsilicone.Theexhaustventistheonlypartofthesystemthatisunderpositivepressure.Fire has gone out- check for status light.1. Nofuelinhopper.2. Draftistoolow,blockedflue.3. Somethingisrestrictingfuelflow.4. Hopperlidnotclosedproperly.5. Feedmotororcombustionblowerhasfailed.

FuelPelletfuelsareputinto3categoriesintermsofashcontent.Premiumat1%orless,Standardat3%orlessandallothersat3%ormore.TheP38+iscapableofburningall3categoriesofpelletsduetoapatentedfeederandburnpotsystem.Itshouldbenoted,however, thathigherashcontent,andwhenmixingwith corn, will requiremore frequent ashremoval, scraping of the burn pot, andmayprovide lessBTU'sperpound.Normally,standardandhighashpelletscost less thanpremiumpellets and canbe cost effectivewhenburnedintheP38+.Themoisturecontentofpelletsmustnotexceed8%,andcorn15%.HighermoisturewillrobBTU'sandmaynotburnproperly. Fuel shouldnot be storedwithin the stove installationclearancesorwithinthespacerequiredforchargingandashremoval.SeePage7.

Page 25: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

25 PP38+ Pellet Stove 3-90-08422JR11_03/14

Specifications

weight 212 lbs.blower 135 cfmFeed rate approximate .75lb. to 5.5 lbs per hrhopper capacity 50 lbsFuel wood PelletsFlue size 3 inchoutside air size 3 inchFuse rating 6 amp

22”

5 1/16"

13 3

/4"

10 1

/4"

33 1

/8"

28 5

/16"

Page 26: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

26PP38+ Pellet Stove3-90-08422JR11_03/14

optionsside heat shields -Part#1-00-773863Sideheatshieldsareavailabletoreducetheclearancetocombustiblematerials.

hopper extension -Part#1-00-08536Thehopper extension allows you to putmore pellet fuelinthehopperwhichextendstheburntimeononeloadofpellets.Thehopperextensionadds60poundstotheexistinghoppercapacity,allowingyoutoload120poundsofpelletsatonetime.Theextensionsealstotheunithopperwiththreelatches.Somemodelswillrequireaknockoutberemovedfromtheunithopperpriortoinstallingtheextension.

decorative tile/grey slate optionsTheslatetilesmeasure11.938"x5.938".Thetileframe(partoftrimkit)isnecessarytoholdtheslateinplaceonthestove.Thereare4decorativeslatechoices.Seedealerforsamples.TheBrushedStainlessdeercutout,picturedbelow,isanotheroptionavailable.Thiscutoutrevealsthecolorofthestovethroughthecutoutshapes.

5.938"

11.938"

Frame Tile/Slate

direct vent wall Passthrough kitYoumay choose to use the optional Direct VentWallPassthroughKit (part #1-00-677177)which incorporatesventingpassthroughandoutsideairintoonecomponent.

On the rear of the stove hopper there is a hole to fasten the hopper extension into place.On some units, this hole will need to beopened. You will notice a small uncut area on rear of the knockout. Push downward with a screwdriver or like tool until the knockout is rotated as far back to the inside of the hopperas possible. This will allow the swell latch of thehopper extension to fully expand to the bottomside of the hole for a proper seal.

Page 27: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

3-90-08422JR11_03/1427 PP38+ Pellet Stove

Harman® pellet burning, free-standing stoves and inserts have been tested to ASTM E1509 for burning shelled corn in a mixture with wood pellets. The listing approves up to a 50% corn and 50% pellet mixture. Different mixtures of corn will have distinctively different burn characteristics depending upon moisture content and variety. The operator should closely monitor the stove’s operation when burning a new corn/pellet mixture or a different variety of corn, and make any necessary adjustments to feed rate. Since corn is typically higher in ash and moisture content, cleaning and ash removal will be needed more frequently.

Operation in Stove Temp modeSet feed adjuster to # 3. Set temperature knob to #3, Turn mode selector knob onto “Stove Temp” mode. After the fire has lit, watch that the fuel does not feed too fast that it pushes the red glowing fuel bed off of the burn pot grate. If it does, lower the feed adjuster setting or use a lower percentage of corn in the mixture. After the stove has burned for 10 minutes and the entire fuel bed is burning, the feed adjuster and temperature knobs may be adjusted for higher heat output if desired. Maximum feed has been reached when the fire bed is about ½ to 1 inch from the end of the burn pot. Settings will vary with different types, moisture levels and mix ratios of corn. If you are having difficulty burn-ing a 50% corn / 50% wood pellet mixture, try a lower percentage of corn.

Operation in Room Temp modeSet feed adjuster to # 2 or # 3. Set temperature knob to desired amount. Turn mode selector knob onto “Room Temp” mode. After the fire has lit, watch that the fuel does not feed too fast that it pushes the red glowing fuel bed off of the burn pot grate. After the stove has burned for 10 minutes and the entire fuel bed is burning, the feed adjuster may be set to a higher output level if desired. Maximum feed has been reached when the fire bed is about ½ to 1 inch from the end of the burn pot. It is recommended that after burning at the desired settings, turn the stove off and allow it to cool, then turn it back on in “Room Temp” mode and watch the stove restart and verify correct operation. Settings will vary with different types, moisture levels and mix ratios of corn. If you are having difficulty burning a 50% corn 50% wood pellet mixture, try a lower percentage of corn.

Changes to Maintenance ScheduleWood pellets average around 6% moisture content or less. Corn will be 14 or 15% moisture. With more moisture in the fuel, more maintenance will be incurred. Burn pot scraping may need to be done once per day. The ash pan will fill more quickly and may need emptied weekly. Most importantly, remove the burn pot cleanout cover weekly to clean the air passage and the igniter element. Excessive buildup on the igniter may lead to shortened igniter life.

Venting Consideration: Check with your venting manufacturer regarding possible exclusions when a mixture of corn and pellets is burned.

Addendum for Burning Corn and Pellet Fuel Mixture

Loosen these two wing screws for access to clean the air passage and igniter.

* For P38+ model, follow Stove Temp instructions. Keep feed rate on #3 or above when using a wall thermostat.

Page 28: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

28PP38+ Pellet Stove3-90-08422JR11_03/14

Fuel SpecificationsFuel and Fuel storagePellet fuel quality can fluctuate from manufacturer tomanufacturer,andevenfrombagtobag.Hearth&HomeTechnologiesrecommendsusingonlyfuelthatiscertifiedbythePelletFuelsInstitute(PFI).FuelMaterial• Madefromsawdustand/orotherwoodby-products• Shelledfieldcorn(whenmixedwithwoodpellets)• Sourcematerialtypicallydeterminesashcontent

HigherAshContentMaterial• Hardwoodswithhighmineralcontent• Barkandleavesassourcematerial• "Standard"gradepellets,cornandotherbiomass

LowerAshContentMaterial• Softwood;pine,fir,etc.• Materialswithlowermineralcontent• "Premium"gradepellets

Shelledfieldcorn• Mustbe15%moisturecontentorless• Mustbecleanandfreeofdebris• Mustbemixedwithwoodpellets.(Upto50%)• Stalk parts, excessive fines and cob remnants may

causefeedsystemjamsorblockage

CAUTION! Do not burn fuel that contains an additive; (such as soybean oil) • Maycausehopperfire• DamagetoproductmayresultRead the list of ingredients on the packaging. If you arebuyingfieldcorn,theonlyingredient listedshouldbefieldcorn.

WARNING! Risk of Chemical Poisoning!DoNOTburntreatedseedcorn• Chemicalpesticidesareharmfulorfatalifswallowed• Burningtreatedseedcornwillvoidtheproductwarranty

ClinkersMinerals and other non-combustible materials, like sand,willturnintoahardglass-likesubstancewhenheated.Treesfromdifferentareaswillvaryinmineralcontent.Forthis reason, some fuels will produce more clinkers thanothers.

MoistureAlways burn dry fuel. Burning fuel with high moisturecontenttakesenergytodryandtendstocooltheappliancethus,robbingheatfromyourhome.Damppelletfuelcouldturnbackintosawdustwhichdoesnotflowproperlythroughthefeedsystem.

Size• Pellets are either 1/4 inch or 5/16 inch (6-8mm) in

diameter• Lengthshouldbenomorethan1-1/2inches(38mm)• Pellet length can vary from lot to lot from the same

manufacturer

Performance• Higherashcontentrequiresmorefrequentmaintenance.• "Premium" grade pelletswill produce the highest heat

output.• Burning pellets longer than 1-1/2 inches (38mm) can

causeinconsistentfeedingand/orignition.

Werecommendthatyoubuyfuelinmulti-tonlotswheneverpossible. However, we do recommend trying differentbrands prior to purchasing multi-ton lots, to ensure yoursatisfaction.

CAUTION! Attempting to burn fuels such as charcoal has the potential of generating Carbon Monoxide which is DEADLY. Never burn fuels other than those listed on the appliance safety label.

Whenchangingfromwoodpelletstoacorn/pelletmixture,theFEEDADJUSTERwill likelyneedadjusted toa lowersetting.Whenundermaximumdemand,ensurethereisnounburnedfuelbeingpushedintotheashpan.

Storage• Woodpelletsshouldbeleft intheiroriginalsealedbag

untilreadytouse,topreventmoisture.• Shelledcornshouldbestoredinatightlysealedcontainer

topreventmoistureandtodeterpests• Donotstorefuelwithinthespecifiedclearanceareas,or

inalocationthatwillinterferewithroutinecleaningandmaintenanceprocedures.

noticeHearth&HomeTechnologiesisnotresponsibleforstove performance or extra maintenance requiredasaresultofusing fuelwithhigherashormineralcontent.

TestedandapprovedforusewithwoodpelletsandamixtureofshelledfieldcornandwoodpelletsONLY.Burningofanyotherfuelwillvoidyourwarranty.

CAUTION!

Page 29: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

29 PP38+ Pellet Stove 3-90-08422JR11_03/14

18/3 RUBBER CORD

MA

LE/F

EMA

LE C

ON

NEC

TIO

NS

DIS

TRIB

UTI

ON

BLO

WER

FEED

ER A

UG

ER M

OTO

R

STA

ND

ARD

USE

WAT

TS -

336

@ 1

00VA

C 50

Hz

= 2.

8 A

LOW

PRE

SSU

RE S

WIT

CH

COM

BUST

ION

MO

TOR

N.O

. CO

NTA

CTS

MA

LE/F

EMA

LE C

ON

NEC

TIO

NS

1 42 3 65 987

WH

ITE

WH

ITE

WH

ITE

WH

ITE

BLU

E

EMPT

YEM

PTY

PLU

GG

EDBR

OW

N

11BL

ACK

PART

NO

. 3-9

0-77

3869

J

WHITE 11 PIN PLUG

10RE

D

GRE

EN

BON

DED

TO

STO

VE B

OD

YG

REEN

WIR

E IS

GRO

UN

D

18/3

RU

BBER

CO

RD

POW

ER C

ORD

ESP

HA

RMA

N P

38 P

ELLE

T ST

OVE

WIR

ING

DIA

GRA

M

BOA

RD

CON

TRO

L

BRO

WN

WH

ITE

RED

BLU

E

WH

ITE

WHITE

GREEN

MA

LE/F

EMA

LE C

ON

NEC

TIO

NS

ESP

BLACK

ROO

M S

ENSO

R PO

RTS

WHITE

ESP

PRO

BE

31 9 10 115 6 84

6 A

MP

GLA

SS F

USE

MAX

. WAT

TS -

336

@ 1

00/1

20VA

C 50

Hz/

60H

z =

2.8

A

wiring diagram

Page 30: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

3-90-08422JR11_03/14

4021-645F02-18-13 Page1of2

hearth & home technologiesliMited liFetiMe warrantY

Hearth&HomeTechnologies,onbehalfofitshearthbrands(”HHT”),extendsthefollowingwarrantyforHHTgas,wood,pellet,coalandelectrichearthappliancesthatarepurchasedfromanHHTauthorizeddealer.

warrantY coverage:HHTwarrantstotheoriginalowneroftheHHTapplianceatthesiteofinstallation,andtoanytransfereetakingownershipoftheapplianceatthesiteofinstallationwithintwoyearsfollowingthedateoforiginalpurchase,thattheHHTappliancewillbefreefromdefectsinmaterialsandworkmanshipatthetimeofmanufacture.Afterinstallation,ifcoveredcompo-nentsmanufacturedbyHHTarefoundtobedefectiveinmaterialsorworkmanshipduringtheapplicablewarrantyperiod,HHTwill,atitsoption,repairorreplacethecoveredcomponents.HHT,atitsowndiscretion,mayfullydischargeallofitsobligationsundersuchwarrantiesbyreplacingtheproductitselforrefundingtheverifiedpurchasepriceoftheproductitself.Themaximumamountrecoverableunderthiswarrantyislimitedtothepurchasepriceoftheproduct.Thiswarrantyissubjecttoconditions,exclusionsandlimitationsasdescribedbelow.

warrantY Period:Warrantycoveragebeginsonthedateoforiginalpurchase.Inthecaseofnewhomeconstruction,warrantycoveragebeginsonthedateoffirstoccupancyofthedwellingorsixmonthsafterthesaleoftheproductbyanindependent,authorizedHHTdealer/distributor,whicheveroccursearlier.Thewarrantyshallcommencenolaterthan24monthsfollowingthedateofproductshipmentfromHHT,regardlessoftheinstallationoroccupancydate.Thewarrantyperiodforpartsandlaborforcoveredcomponentsisproducedinthefollowingtable.Theterm“LimitedLifetime”inthetablebelowisdefinedas:20yearsfromthebeginningdateofwarrantycoverageforgasappliances,and10yearsfromthebeginningdateofwarrantycoverageforwood,pellet,andcoalappliances.Thesetimeperiodsreflecttheminimumexpectedusefullivesofthedesignatedcomponentsundernormaloperatingconditions.

Seeconditions,exclusions,andlimitationsonnextpage.

Parts Labor Gas Wood Pellet EPAWood Coal Electric Venting

X X X X X X X

AllpartsandmaterialexceptascoveredbyConditions,

Exclusions,andLimitationslisted

X X X Igniters,electroniccomponents,andglass

X X X X X Factory-installedblowersX Moldedrefractorypanels

X Firepotsandburnpots

5years 1year X X Castingsandbaffles

7years 3years X X X Manifoldtubes,HHTchimneyandtermination

10years 1year X Burners,logsandrefractory

LimitedLifetime 3years X X X X X Fireboxandheatexchanger

X X X X X X X Allreplacementpartsbeyondwarrantyperiod

WarrantyPeriod HHTManufacturedAppliancesandVenting

1Year

ComponentsCovered

3years

2years

90Days

Page 31: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

3-90-08422JR11_03/1431 PP38+ Pellet Stove

4021-645F02-18-13 Page2of2

warrantY conditions:• ThiswarrantyonlycoversHHTappliancesthatarepurchasedthroughanHHTauthorizeddealerordistributor.Alistof

HHTauthorizeddealersisavailableontheHHTbrandedwebsites.• ThiswarrantyisonlyvalidwhiletheHHTapplianceremainsatthesiteoforiginalinstallation.•ThiswarrantyisonlyvalidinthecountryinwhichtheHHTauthorizeddealerordistributorthatsoldtheappliance

resides.• Contactyourinstallingdealerforwarrantyservice.Iftheinstallingdealerisunabletoprovidenecessaryparts,contact

thenearestHHTauthorizeddealerorsupplier.Additionalservicefeesmayapplyifyouareseekingwarrantyservicefromadealerotherthanthedealerfromwhomyouoriginallypurchasedtheproduct.

• Checkwithyourdealerinadvanceforanycoststoyouwhenarrangingawarrantycall.Travelandshippingchargesforpartsarenotcoveredbythiswarranty.

this warranty is void if:• Theappliancehasbeenover-firedoroperatedinatmospherescontaminatedbychlorine,fluorine,orotherdamaging

chemicals.Over-firingcanbeidentifiedby,butnotlimitedto,warpedplatesortubes,rustcoloredcastiron,bubbling,crackinganddiscolorationofsteelorenamelfinishes.

• Theapplianceissubjectedtoprolongedperiodsofdampnessorcondensation.• Thereisanydamagetotheapplianceorothercomponentsduetowaterorweatherdamagewhichistheresultof,but

notlimitedto,improperchimneyorventinginstallation.

liMitations oF liabilitY:• Theowner’sexclusiveremedyandHHT’ssoleobligationunderthiswarranty,underanyotherwarranty,expressor

implied,orincontract,tortorotherwise,shallbelimitedtoreplacement,repair,orrefund,asspecifiedabove.InnoeventwillHHTbeliableforanyincidentalorconsequentialdamagescausedbydefectsintheappliance.Somestatesdonotallowexclusionsorlimitationofincidentalorconsequentialdamages,sotheselimitationsmaynotapplytoyou.Thiswarrantygivesyouspecificrights;youmayalsohaveotherrights,whichvaryfromstatetostate.EXCEPTTOTHEEXTENTPROVIDEDBYLAW,HHTMAKESNOEXPRESSWARRANTIESOTHERTHANTHEWARRANTYSPECIFIEDHEREIN.THEDURATIONOFANYIMPLIEDWARRANTYISLIMITEDTODURATIONOFTHEEXPRESSEDWARRANTYSPECIFIEDABOVE.

warrantY eXclusions:Thiswarrantydoesnotcoverthefollowing:• Changesinsurfacefinishesasaresultofnormaluse.Asaheatingappliance,somechangesincolorofinteriorand

exteriorsurfacefinishesmayoccur.Thisisnotaflawandisnotcoveredunderwarranty.• Damagetoprinted,plated,orenameledsurfacescausedbyfingerprints,accidents,misuse,scratches,melteditems,

orotherexternalsourcesandresiduesleftontheplatedsurfacesfromtheuseofabrasivecleanersorpolishes.• Repairorreplacementofpartsthataresubjecttonormalwearandtearduringthewarrantyperiod.Theseparts

include:paint,wood,pelletandcoalgaskets,firebricks,grates,flameguides,batteriesandthediscolorationofglass.• Minorexpansion,contraction,ormovementofcertainpartscausingnoise.Theseconditionsarenormalandcom-

plaintsrelatedtothisnoisearenotcoveredbythiswarranty.• Damagesresultingfrom:(1)failuretoinstall,operate,ormaintaintheapplianceinaccordancewiththeinstallation

instructions,operatinginstructions,andlistingagentidentificationlabelfurnishedwiththeappliance;(2)failuretoinstalltheapplianceinaccordancewithlocalbuildingcodes;(3)shippingorimproperhandling;(4)improperopera-tion,abuse,misuse,continuedoperationwithdamaged,corrodedorfailedcomponents,accident,orimproperly/incorrectlyperformedrepairs;(5)environmentalconditions,inadequateventilation,negativepressure,ordraftingcausedbytightlysealedconstructions,insufficientmake-upairsupply,orhandlingdevicessuchasexhaustfansorforcedairfurnacesorothersuchcauses;(6)useoffuelsotherthanthosespecifiedintheoperatinginstructions;(7)installationoruseofcomponentsnotsuppliedwiththeapplianceoranyothercomponentsnotexpresslyauthorizedandapprovedbyHHT;(8)modificationoftheappliancenotexpresslyauthorizedandapprovedbyHHTinwriting;and/or(9)interruptionsorfluctuationsofelectricalpowersupplytotheappliance.

• Non-HHTventingcomponents,hearthcomponentsorotheraccessoriesusedinconjunctionwiththeappliance.• Anypartofapre-existingfireplacesysteminwhichaninsertoradecorativegasapplianceisinstalled.• HHT’sobligationunderthiswarrantydoesnotextendtotheappliance’scapabilitytoheatthedesiredspace.Informa-

tionisprovidedtoassisttheconsumerandthedealerinselectingtheproperappliancefortheapplication.Consider-ationmustbegiventoappliancelocationandconfiguration,environmentalconditions,insulationandairtightnessofthestructure.

Page 32: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

3-90-08422JR11_03/1432 PP38+ Pellet Stove

service Parts P38 Pellet (japan)beginning Manufacturing date: Feb 2011

ending Manufacturing date: active

Part number list on following page.

1-90-08505-1 (black),

ending Manufacturing date: june 20111-90-08505-2 (charcoal), 1-90-08505-3 (goldenfi re))

1

32

4

5

8

6 7

9 1011 12

13

16

15

14

1718

19

20

2122

23

steel Pellet stove

10/13

Page 33: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

3-90-08422JR11_03/1433 PP38+ Pellet Stove

service Parts P38 Pellet (japan)beginning Manufacturing date: Feb 2011

ending Manufacturing date: active

IMPORTANT:THISISDATEDINFORMATION.Partsmustbeorderedfromadealerordistributor.hearth and home technologies does not sell directly to consumers.Providemodelnumberandserialnumberwhenrequestingservicepartsfromyourdealerordistributor.

iteM description coMMents Part nuMber1 HopperAssembly 1-10-09539A

HopperThroatGasket 3-44-677185HopperSwitch48” 3-20-232108

2 FeederAssembly 1-10-09535JA2.1 PelletFeederGearMotor,4RPM 3-20-501202.2 ULFeederCamBearing 3-31-30142.3 FeederAirCrossoverKit 1-00-67900

9MMSiliconeTube 5Ft 1-00-5114272.4 PelletAirIntakeAssembly 1-10-06810A2.5 GasketFeederAirIntake Pkgof6 3-44-72224-62.6 ULFeederAirIntake 1-10-722222.7 GasketUltraAirIntake Pkgof10 3-44-677160-102.8 UltraFeederWeldment 1-10-7241322.9 ULFeederPusherArm 1-10-677187W2.10 Gasket,ULFeederCover 1-00-6771222.11 SlidePlateAssembly 1-10-677121A2.12 ULFeederAugerAssembly 3-50-005652.13 BearingFlangew/Hardware 1-00-040352.14 ULFeederGearMotorBracketw/Grommet 1-00-2474062.15 ULFeederCamBlock 3-00-677154

HopperSwitchfitting Pkgof2 1-00-142818MotorBracketGrommet Pkgof12 3-31-2761-12PillowBlock Pkgof4 3-31-3614087-4

Additionalservicepartsonfollowingpage.

2.7

2.6

2.5

2.4

2.3

2.2

2.1

2.15

2.8

2.9

2.10

2.11

2.12

2.13

2.14

#2 Feeder assembly

Page 34: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

3-90-08422JR11_03/1434 PP38+ Pellet Stove

service Parts P38 Pellet (japan)beginning Manufacturing date: Feb 2011

ending Manufacturing date: active

IMPORTANT:THISISDATEDINFORMATION.Partsmustbeorderedfromadealerordistributor.hearth and home technologies does not sell directly to consumers.Providemodelnumberandserialnumberwhenrequestingservicepartsfromyourdealerordistributor.

iteM description coMMents Part nuMber3 FlueTailPipe 3-00-2472374 AugerMotorCover 2-00-773852J5 AugerMotorShield 2-00-773815P6 DifferentialSwitch 3-20-68667 DistributionBlower 3-21-336478 CombustionMotor 3-21-09640

CombustionBlowerMountingScrews Pkgof100 1-00-534832089 RearCoverLeft 2-00-773828-1P10 RearCoverRight 2-00-773828-2P11 CombustionIntakeWeldment 1-10-08516S12 RetainerAssembly 1-10-08533S13 AshPan 1-10-7738108A14 AshDoorAssembly 1-10-7738106A15 BoltonHingeWeldment 2-00-06952B16 CastDoorFrame 4-00-06800P

CastDoorw/Glass 1-10-06800A17 GlassPanel 3-40-950133125

18 DoorHandleAssembly(Contains:PawBolt,WoodenHandle,WashersandScrews.) 1-00-453001

WoodenHandle,LoadDoor 1-00-0024719 BurnPotWeldment 1-10-08514

FlameGuide 3-00-08534CleanOutCover 2-00-06112ThumbScrew Pkgof10 3-31-782108-10

20FireBrick4-1/2x9x1-1/4" Pkgof7 1-00-900450125FireBrick,FullSkid 414Pcs 3-40-900450-414

21 HopperHeatShield 2-00-773854B22 FeederCover 2-00-77385323 CircuitBoardw/Knobs&Shafts 1-00-06142

CircuitBoardPlate 1-10-08649Knob,ContolBoard/D-Shaft 25Sets 1-00-015605

Additionalservicepartsonfollowingpage.

Page 35: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

3-90-08422JR11_03/1435 PP38+ Pellet Stove

service Parts P38 Pellet (japan)beginning Manufacturing date: Feb 2011

ending Manufacturing date: active

IMPORTANT:THISISDATEDINFORMATION.Partsmustbeorderedfromadealerordistributor.hearth and home technologies does not sell directly to consumers.Providemodelnumberandserialnumberwhenrequestingservicepartsfromyourdealerordistributor.

iteM description coMMents Part nuMberAirwashO-Rings Pkgof10 1-00-939639ArrowBurnPotScraper Pkgof10 2-00-773850-10CastWeldonDoorHinge Qty2req 3-00-773813DiagnosticDisplayModule 3-20-05401

DDMReplacementCable 1-00-05402

Disconnect,Female Pkgof25 1-00-00959DraftMeterAssembly 1-00-00637

DraftMeterBolt&Tube 1-00-04004

FanBlade,5”DoublePaddle(CombustionBlower) 3-20-502221Fuse,6Amp Pkgof5 3-20-49447-5Gasket,1/4”RopeBlackW/PSA(Glass) 15Ft 1-00-2312Gasket,3/8”RopeWhiteLD(AshDoororLoadDoor) 30Ft 1-00-00888Gasket,BurnPot/Tailpipe Pkgof5 1-00-07381Gasket,Hopper 10Ft 1-00-00248GlassClip&Hardware 1Set 1-00-249140HopperLidW/HInge 1-10-08518Labels,Caution&Danger 10ea 1-00-200408541Label,Caution 3-90-00247Latch,Swell/HopperAndSpacer 1-00-199110

RubberSpacers Pkgof10 3-31-901311-10OutsideAirVent 1-10-09542PowerCord 3-20-39685RoomSensor 3-20-00906Screw,#10-24x3/8”AlloySteelBlackOxideButtonHeadCap Pkgof100 3-30-3011-100SiliconeTubing,1/8” 5Ft 1-00-5113574ThermisterProbe(ESPProbe) 3-20-00844WiringHarness Pre008190059 3-20-773868WiringHarness Post008190059 3-20-08727

TileFrameGold 3-43-06729-4BrushedStainless 3-43-06729-7BrightNickel 3-43-06729-8

SpringClips(RequiredforinstallationofTileFrame) Pkgof20 3-31-232547-20

LeafDoorTrimGold 3-43-06802-4BrushedStainless 3-43-06802-7BrightNickel 3-43-06802-8

ModernDoorTrim BrushedStainless 3-43-06839-7

AshlipTrimGold 3-43-08400BrushedStainless 3-43-08400-7BrightNickel 3-43-08400-8

Page 36: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé
Page 37: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

37 PP38+ Pellet Stove 3-90-08422JR11_03/14

service & Maintenance log

date of service description of servicePerformed by

Page 38: NOTICE: SAVE THESE INSTRUCTIONS WARNING...008 Serial No. N o de série: Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / Testé

At Harman, we build each product to a standard, not a price.This powerful heating appliance boasts uncompromising attention to detail and helps preserve our planet by using environmentally responsible fuels.

(Signature of Boxer)

Your premium quality hearth product designed and assembled by the experienced and skilled members at Harman in Halifax, PA, USA.

Proudly Printed On 100% Recycled Paper